acurlite structural skylights, inc. for commercial daylighting - all … · 2020. 6. 3. · use...

Post on 21-Jan-2021

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

ISOMETRIC VIEW

DOUBLE PITCHW/ GABLE END C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

SAMPLE

N.T.S.

INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Backer)

ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)

SILICONE GASKET

BACKER ROD & CONTINUOUS SEAL

EXTRUDED ALUMINUM PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

FASTEN PURLIN ASSEMBLY TO RAFTER

EXTRUDED ALUMINUM RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

TYPICAL DETAIL

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

30.26°712

D1

INSTALLATION

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

EXTRUDED ALUM. COVER CAP & PRESSURE CAP W/ GASKET

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Provided For Additional Cost)

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)

MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)

FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)

INSTALL SILL PAN IN BED OF SEALANT

SPONGE GASKET - FACTORY APPLIED TO SILL PAN(3/4" Void At System Weep As Required)

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

(Typical Splice Shown As Dashed Line - Locate As Required)

SILL

DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

STRUCTURAL SEAL FLANGE - IF REQUIRED(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

APPLY CONT. STRUCTURAL SEAL - IF REQUIRED

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

FASTEN EXTERIOR CLOSURE TO SILL PAN(Use #10 x 1/2" Pan Head S.M.S. - Locate 12" O.C. Typical)

FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

OPTIONS FOR THERMAL ENHANCEMENT

SNAP ON COVER CAP(Not Required For Water Tightness)

CURB / SUBSTRUCTURE BY OTHERS

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)

OPTIONS FOR VISUAL ENHANCEMENT

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D1

6" = 1' - 0"

BACKER ROD & CONTINUOUS SEAL

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

OPTIONS FOR VISUAL ENHANCEMENT

FASTEN PURLIN ASSEMBLY TO RAFTER

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)30.26°7

12

INSTALLATION

APPLY CONT. STRUCTURAL SEAL - IF REQUIRED

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

SILICONE GASKET

ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

STRUCTURAL SEAL FLANGE FASTENED TO PURLIN(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

SNAP ON COVER CAP(Not Required For Water Tightness)

PURLINTYPICAL DETAIL

D2 C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D2

6" = 1' - 0"

TYPICAL DETAILRIDGE

D3

FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE

FASTEN PURLIN ASSEMBLIES TO RAFTER

FASTEN RAFTER ASSEMBLIES TOGETHER - IF REQ.(Gusset Factory Applied to (1) Rafter Assembly Of Each Pair)

BACKER ROD & CONTINUOUS SEAL

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

APPLY CONT. STRUCTURAL SEAL - IF REQUIRED

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

INSTALLATION

SNAP ON COVER CAP(Not Required For Water Tightness)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

30.26°712

MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)

INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Backer)

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)

SILICONE GASKET

EXTRUDED ALUMINUM PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUMINUM RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)

EXTRUDED ALUM. COVER CAP & PRESSURE CAP W/ GASKET

STRUCTURAL SEAL FLANGE - IF REQUIRED(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)

OPTIONS FOR THERMAL ENHANCEMENT

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

ALUMINUM GUSSET PLATES(Size, Thickness & Type Per Acurlite P.E. Analysis)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D3

6" = 1' - 0"

TYPICAL DETAILJAMB

D4

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

SILICONE GASKETEXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

CURB / SUBSTRUCTURE BY OTHERS

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

COUNTER FLASHING & REGLETS(Not By Acurlite - Provided By Others)

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

SNAP ON COVER CAP(Not Required For Water Tightness)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

FASTEN EXTERIOR CLOSURE TO CURB(Shim & Seal As Required)

INSTALLATION

LAP MEMBRANE INTO SYSTEM(Not By Acurlite - Provided By Others)

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)

FASTEN EXTERIOR CLOSURE TO ANGLE SPACER(Not By Acurlite - Provided By Others)

FORMED ANGLE SPACER - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Factory Applied To Rafter)

FASTEN PURLIN ASSEMBLY TO RAFTERBACKER ROD & CONTINUOUS SEAL

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D4

6" = 1' - 0"

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

SILICONE GASKET

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

FASTEN PURLIN ASSEMBLY TO RAFTER

EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSTALLATIONOPTIONS FOR VISUAL ENHANCEMENT

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

SNAP ON COVER CAP(Not Required for Water tightness)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

ALUM. GUSSET PLATES(Size & Type Per Acurlite P.E. Analysis)

FASTEN RAFTER ASSEMBLIES TOGETHER - IF REQ.(Gusset Factory Applied to (1) Rafter Assembly Of Each Pair)

RAFTERTYPICAL DETAIL

D5

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D5

6" = 1' - 0"

GABLE HEADD6

TYPICAL DETAIL

SILICONE GASKETEXTRUDED ALUM. PURLIN

(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)

INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Alum. Backer)

DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)

OPTIONS FOR THERMAL ENHANCEMENT

FASTEN HEAD LUG TO RAFTER(Seal In & Around Lug & Fastener)

FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

(Typical Splice Shown As Dashed Line - Locate As Required)

INSTALLATION

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

GABLE HEAD LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

FASTEN PURLIN ASSEMBLY TO RAFTER

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

SNAP ON COVER CAP(Not Required For Water Tightness)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D6

6" = 1' - 0"

TYPICAL DETAILGABLE SILL

D7

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

CURB / SUBSTRUCTURE BY OTHERS

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)

SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

SPONGE GASKET - FACTORY APPLIED TO SILL PAN(3/4" Void At System Weep As Required)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

SILICONE GASKET

FORMED ANGLE SPACER - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Factory Applied To Purlin)

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

OPTIONS FOR VISUAL ENHANCEMENT

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)

(Not by Acurlite - Provided By Others)

INSTALLATION

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

FASTEN PURLIN ASSEMBLY TO RAFTER

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

INSTALL SILL PAN IN BED OF SEALANT

FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)

FASTEN EXTERIOR CLOSURE TO SILL PAN(Use #10 x 1/2" Pan Head S.M.S. - Locate 12" O.C. Typical)

FASTEN EXTERIOR CLOSURE TO ANGLE SPACER(Use Pop Rivets As Required)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

SNAP ON COVER CAP(Not Required For Water Tightness)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D7

6" = 1' - 0"

TYPICAL DETAILGABLE POST

D8

SILICONE GASKETEXTRUDED ALUM. PURLIN

(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

SNAP ON COVER CAP(Not Required For Water Tightness)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

INSTALLATION

FASTEN PURLIN ASSEMBLY TO RAFTER

FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)

INSTALL SILL PAN IN BED OF SEALANT

SILL CURB - INSIDE EDGE(Not Provided By Acurlite - Provided By Others)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D8

6" = 1' - 0"

top related