advanced, simple, and revolutionary. fully automated at .../media/il/docs/product/critical...
Post on 03-Feb-2020
4 Views
Preview:
TRANSCRIPT
Advanced, simple, and revolutionary.
Fully automated at the touch of a button.
INL-267 DECENT 8.5x11.indd 1 5/10/11 9:14 AM
Simply press GO!u iQM: Automates quality assurance
u GEMweb Plus Custom Connectivity: Automates information management
u Multi-use PAK: Automates maintenance
GEM Premier 4000Brings complete automation to critical care testing—at the touch of a button.
Automation and quality care go hand in hand.Fully automated maintenance, quality control and information management help to ensure patient safety and enhance patient care.
INL-267 DECENT 8.5x11.indd 2 5/10/11 9:14 AM
2
† Onboard use-life is 21 days.* Cartridges available with or without Total Bili.
PAK SizE
MEnu 75 150 300 450 600† Onboard use-life
Blood Gas, Hct, tHb, O2Hb, HHb, MetHb, sO2, Total Bili* 30 days
Blood Gas, Electrolytes, Hct, tHb, O2Hb, HHb, MetHb, sO2, Total Bili* 30 days
Blood Gas, Electrolytes, Glu, Lac, Hct, tHb, O2Hb, HHb, MetHb, sO2, Total Bili* 30 days
Menus with: Creat, BUN, measured tCO2 are in development.
Ultimate Flexibilityu Standardized platform for the lab and at the point-of-care
u Full analyte menu and integrated CO-Oximetry
u Accepts a syringe, capillary tube or ampule
u Multiple menu and volume PAK configurations
INL-267 DECENT 8.5x11.indd 3 5/10/11 9:14 AM
References:1. Westgard JO, Fallon KD, Mansouri S. Validation of iQM Active Process Control Technology. Point of Care, The Journal of Near-Patient Testing and Technology, 2003: Vol. 2, No. 1. 2. Toffaletti JG, McDonnell EH, Ramanathan LV, Tolnai J, Templin R, Pompa L. Validation of a quality assessment for a blood gas and electrolyte testing. Clinica Chimica Acta,
382 (2007) 65–70.
“ iQM: a new standard for the future of QC.” – James Westgard, PhD, developer of the ‘Westgard Rules’
3
Reduces Error Detection Time from Hours to Minutes1, 2
pH pO2 pCO2 na+ K+ Ca++ Glu Lac Hct
iQM 3 mins 3 mins 3 mins 17 mins 3 mins 3 mins 11 mins 6 mins 3 mins
Traditional QC (Manual or Auto) ≥8 hrs ≥8 hrs ≥8 hrs ≥8 hrs ≥8 hrs ≥8 hrs ≥8 hrs ≥8 hrs ≥8 hrs
Statistical presentation of an average error detection time with 95% confidence.
Automated Quality Assurance iQM: Intelligent Quality ManagementThe most accurate results, every time, for maximum efficiency and enhanced patient care.
Automatically monitors all components. Provides continuous error detection and correction.
Time
iQM Continuous Model
= Error automatically detected, corrected and documented immediately
= Optimal test results ensured
0 Continuous
Time = Error undetected!= Questionable test results (all results
from eight-hour period require review)?
0QC IN QC OUT
!
8 hrsTime
?Traditional QC (Manual or Auto) Eight-hour Model
INL-267 DECENT 8.5x11.indd 4 5/10/11 9:14 AM
IL’s patented iQM and all analytical components are included inside a single-component, self-contained PAK.
4
Positive Impact on Staff Time
Manual Quality Control
Manual Troubleshooting
Manual Documentation
20
16.5 total hrs
iQM
Traditional Manual QC
Traditional Auto QC
Estimated Labor (hrs/mo/instrument)0
0 total hrs
6.5 total hrs
This means:In a hospital with 8 GEM Premier 4000 analyzers, iQM can save over 1,500 hours annually
u Over 16 hours saved monthly u Over 190 hours saved annually
FDA-cleared in 2002 for GEM Premier 3000, and again in 2006 for GEM Premier 4000, iQM is the only quality management system designed to provide continuous monitoring of the analytical process with real-time, automatic error detection, correction and documentation of all corrective actions, replacing the use of traditional external quality controls.
INL-267 DECENT 8.5x11.indd 5 5/10/11 9:14 AM
Automated Information ManagementGEMweb Plus Custom ConnectivitySystem-wide control from any networked analyzer or PC, customized for your hospital.
The OnLY connectivity software to: u Provide a single user-interface
u Allow system-wide control from any networked PC or GEM Premier 4000
u Automate and customize operator certification and management
PLuS: u Allows automatic review of analyzer
and PAK status
u Alerts operator to replace PAK
u Offers patient history with delta versus previous result with one keystroke
True web-based, bi-directional communication, anywhere.
5
INL-267 DECENT 8.5x11.indd 6 5/10/11 9:14 AM
6
GEMwebAutomated, web-based information management u Single, graphic user-interface
u Bi-directional operator management
u Remote analyzer review and control
u Remote iQM review
u Demographic query
GEMweb Plus 100Everything GEMweb offers AnD:u Remote global/area/analyzer system configuration
u Consolidated: - Analyzer status and control - Operator management - iQM review - Patient information management
u System-wide sample lookup database
u HIS and LIS order receiving and processing
GEMweb Plus 200Everything GEMweb Plus 100 offers AnD:u Automated and customizable operator certification,
including exams
u Advanced regulatory compliance management
GEMweb Plus 100 & 200 Customizable Options More functionality, more flexibilityu Receipt of ADT transmissions
u Automated point-of-care order creation
Samples ManagementAnalyzer321
LockAnalyzer
Menu
ˇ̌CARDIAC/UNIT1: SUPERVISOR Signed In
(0)
pH
pCO2
pO2
Na+
K+
Cl -
Ca++
Hct
Glu
Lac
tBili
tHb
O2Hb
COHb
MetHb
HHb
sO2
Ready
Last Activity: 02/08/2010 14:49:24
450Tests
30Days
Select button to lock or unlock the analyte
GEMweb ®
Samples ManagementAnalyzers321
Menu
ˇ̌ICU/ICU1: SUPERVISOR Signed In
(0)
On
!iQM Active Disconnected Issue Exists
444Tests
27Days
NICU/NICU1Ready
438Tests
23Days
PICU/PICU1Aspirating
112Tests
25Days
CVOR/CVOR1Ready
312Tests
18Days
RT/RT1Ready
215Tests
20Days
ER/ER1Analyzing
515Tests
19Days
Lab/Lab1Present Sample
437Tests
27Days
ICU/ICU1Ready
GEMweb Plus®
Exam Settings RespTherapy
Menu
ˇ̌Home
ICU/ICU1: SUPERVISOR Signed In
(0)
GEMweb Plus On
OKCancelX* Required
Set the passing score as a percentage.
Select ‘Sequential Order’ or ‘Random Order’ to set the exam question order.
Selecting ‘Random Order’ will randomly change the order of the questions.
Passing Score (0-100%)
*l80
Total Number of Exam Questions: 20
Sequential Order Random Order
®
INL-267 DECENT 8.5x11.indd 7 5/10/11 9:14 AM
Automated MaintenanceSaves significant staff time and reduces training and documentation requirements.
GEM PAK – The only single-component, multi-use cartridge on the market. u Self-contained; includes all testing components: sensors, CO-Ox optical cell,
lysing solution, Process Control Solutions, tubing, waste container and sampler
u Stored at room temperature
u Easy front-loading
u Replaced every 30 days
Automates the most labor- and skill-intensive processes.u Zero maintenance—just replace the disposable
PAK monthly; no additional cartridge handling required
u Only one PAK to inventory and manage, including all solutions, sensors and quality control
u Immediately detects errors—no hands-on troubleshooting required
u Immediately corrects errors—no hands-on corrective actions required
u Regulatory compliance reports generated automatically
7
PAKs contain all components for patient testing and are ideal for high- and low-volume testing.
INL-267 DECENT 8.5x11.indd 8 5/10/11 9:14 AM
* BG, Electrolytes, Metabolites, Hct I ** Basic Metabolic Panel in development: BUN/Creat and measured tCO2
Automation at the BedsideBringing Simplicity to the Point-of-CareStandardized lab-quality results and real-time connectivity for immediate decisions anywhere in the hospital.
8
CVORimmediate, precise testingu CO-Oximetry, the most accurate method to measure
Hemoglobin, is fully integrated, offering a complete test menu
u Measured Total Hemoglobin not affected by common operative variables, unlike conductive Hematocrit
ICUSaves time and enhances patient careu Provides complete oxygenation status
u Only cartridge-based system to provide Lactate testing in a single sample
u Comprehensive results in a single sample for fast clinical assessments and better outcomes
u Immediately recalls patient information, enhancing safety
NICUFast, reliable results for tiny patientsu The only cartridge-based system to offer Total Bilirubin
u Automatic Fetal Hemoglobin detection and correction
u Capillary-tube sampling (65 µL)*
u Ideal for nitric oxide therapy; no interference from use of Methylene Blue
EDRapid, comprehensive testing**
u Only cartridge-based system to provide Lactate testing in a single sample—key to rapid implementation of sepsis protocol
u tHb for triaging trauma-related blood loss
u COHb, MetHb to manage smoke inhalation treatment
u Advanced GEMweb Plus connectivity—fully integrated, real-time information management
INL-267 DECENT 8.5x11.indd 9 5/10/11 9:14 AM
Simple and flexible, it’s the automatic choice for your hospital.The top choice of hospitals worldwide, the GEM Premier 4000 is advanced, simple, revolutionary and is fully automating critical care testing.
Automated Quality Assurance iQM ensures test quality—24 hours a day, seven days a week, providing continuous error detection and correction.
Automated Information Management GEMweb Plus Custom Connectivity offers true bi-directional communication anywhere—it automates information management and provides system-wide control from any networked PC or GEM Premier 4000.
Automated Maintenance GEM PAKs contain all testing components, are replaced every 30 days and require no refrigeration. Combined with automated detection, correction and documentation, the most labor- and skill-intensive processes are eliminated, saving significant time.
Automation at the Bedside Flexible cartridge test volumes and menu options, including a complete CO-Oximetry panel, and standardized, lab-quality results and real-time connectivity for immediate decisions at the POC.
9
Just press GO!
INL-267 DECENT 8.5x11.indd 10 5/10/11 9:14 AM
Every member of the GEM Family delivers fast, accurate results, in the lab or at the point-of-care, for the very best patient care.
The GEM Family of Critical Care Testing Solutions
GEM Premier GEMweb Plus GEM Complementary Analyzers Custom Connectivity Products
u GEM Premier 4000u GEM Premier 3500
u GEMweb Plus 200u GEMweb Plus 100u GEMweb Plus Customizable Options u GEMweb
u GEMdrawu GEM PCL Plus u GEM OPL
Instrumentation Laboratory
Our Passion. Your Results.Driven by our constant passion for innovation, IL has provided the most comprehensive and valuable diagnostic solutions for decades. From the launch of our first instrument, our integrated solutions continue to revolutionize critical care testing with more capabilities, more end-to-end automation and more flexibility.
INL-267 DECENT 8.5x11.indd 11 5/10/11 9:14 AM
For more information, call 1.800.955.9525 or visit www.ilus.com.The Instrumentation Laboratory logo, GEM, Premier, iQM, GEMweb, and GEM PCL are trademarks of Instrumentation Laboratory Company and/or one of its subsidiaries or parent companies, and may be registered in the United States Patent and Trademark Office and in other jurisdictions. All other product names, company names, marks, logos, and symbols are trademarks of their respective owners.
©2011 Instrumentation Laboratory. All rights reserved.
G4KDCN.SS 05/11
Technical Specifications
Dimensions and WeightAnalyzer H: 18 in, W: 12 in, D: 15 in, Wt: 44 lbsPAK H: 6.75 in, W: 10 in, D: 8 in, Wt: 8 lbs
Sample Volume150 µL BG*/Hct/Lytes**/Glu/Lac/CO-Ox or any subset of the menu that includes CO-Ox100 µL CO-Ox/Total Bili only 65 µL BG/Hct/Lytes/Glu/Lac (micro mode) (capillary only)
*BG = pH, pCO2, pO2 **Lytes = Na+, K+, Ca++, Cl–
Sample Type Heparinized whole bloodHeparinized Plasma (Total Bili)
Time to ResultsAll tests without CO-Ox: 70 seconds from sample introductionAll tests with CO-Ox: 95 seconds from sample introductionSample capacity: 75 – 600 tests
Measurement MethodologyAmperometric: pO2, Glu, Lac, Creat‡
Potentiometric: pH, pCO2, Na+, K+, Ca++, Cl–, BUN,‡ measured tCO2
‡
Conductivity: HctOptical measurement following chemical lysing of the whole blood sample: CO-Ox, Total Bili‡ In development. Not currently saleable.
interface ProtocolsASTM or HL7 enables data transmission to a laboratory, hospital or third-party information management system.
Measured Analytes Analyte Unit Measured Range ¥
pH n/a 6.80 – 8.00pCO2 mmHg 6 – 150pO2 mmHg 5 – 800Na+ mmol/L 100 – 200K+ mmol/L 0.2 – 20.0Ca++ mmol/L 0.10 – 5.00Cl– mmol/L 40 – 170Glu mg/dL 4 – 750Lac mmol/L 0.3 – 20.0Hct % 15 – 75tHb g/dL 3.0 – 23.0O2Hb % –10.0 – 110.0COHb % –10.0 – 110.0MetHb % –10.0 – 110.0HHb % –10.0 – 110.0Total Bili mg/dL 0.3 – 40 BUN‡
Creat‡
tCO2‡
¥ The measured ranges reflect actual numeric value ranges the system can report.
Derived (calculated) ParametersBE(B)BE(ecf)tHb(c)Ca++ (7.4)Anion gapP/F RatiopAO2
CaO2
CvO2
p50O2capsO2
sO2(c)HCO3
– stdHCO3
– (c)A-aDO2
paO2/pAO2
RICcO2
a-vDO2
Qsp/Qt (est)Qsp/Qt
Hct(c)
Werfen GroupWorldwide Locations
Corporate HeadquartersBarcelona, SpainTel. +34-93-4010101www.werfengroup.com
Instrumentation Laboratory HeadquartersBedford, MATel. +1-781-861-0710www.ilww.com
US, Canada, Latin America and South America
IL USA Bedford, MATel. +1-781-861-0710www.ilus.com
Werfen Medical BrazilSão PauloTel. +55 11 4154 3337
IL CanadaRichmond Hill, ONTel. +1-800-552-2025 x6115
IL MexicoCol. Granada Tel. +52-55-5262-1760www.il-mexico.com.mx
Izasa UruguayMontevideoTel. +59-82-4818133
Pacific
Werfen Medical ChinaShanghaiTel. +86-21-32100745
BeijingTel. +86 10 5975 6032
Werfen Hong KongHong KongTel. +852-27927773
IL IndiaNew DelhiTel. +91-11-25191251
IL JapanMinato-ku, TokyoTel. +81-3-5419-1301
Werfen Medical KoreaSeoulTel. +82-2-571-9246www.werfenmedical.com
Europe, Middle East, Africa
Werfen AustriaViennaTel. +43-1-2565800-0
IL BelgiumZaventemTel. +32-2-7252052www.il-be.com
Comesa CzechPragueTel. +420-2-7816047
IL FranceParisTel. +33-1-53338600www.il-france.fr
IL GermanyMunichTel. +49-89-909070www.il-ger.de
IL The NetherlandsBredaTel. +31(0)-76-5480100www.il-nl.com
Comesa Hungary BudapestTel. +36-1-4392910 or 11
IL ItalyMilanTel. +39-02-25221www.il-italia.it
IL Lithuania KaunasTel. +370-37-313157
Comesa PolandWarsawTel. +48-22-3361800
Izasa PortugalCarnaxideTel. +351-21-4247300www.izasa.com
IL RussiaMoscowTel. +7-495-9823723
Izasa SpainBarcelonaTel. +34-93-4010101www.izasa.com
IL UKWarrington, Cheshire Tel. +44-1925-81-0141www.il-uk.com
Instrumentation Laboratory, Comesa and Izasa are companies of Werfen Group.
INL-267 DECENT 8.5x11.indd 12 5/10/11 9:14 AM