Aerohub - general infomation

TRANSCRIPT

Founded by Hussein Bahari and Omar Bahari in 2005, Hub Technologies has invested significantly in research and development involving solid aerosol compound technology

• Hub Technologies intends to be a leader in the fire suppression industry.

• A one-stop centre of choice for fire and safety-related products.

• Setting international industry benchmarks through outstanding solutions and services

• Hub Technologies spearheads transformation of Malaysia as a global leader in Green Technology.

• Particularly the Environmentally Friendly Aerosol-based Fire Suppression Industry

Our Mission

CORPORATE STRUCTURE

ORGANISATIONAL CHART

• Balai Seni Lukis, Malaysia

• Hotel Casuarina, Perak, Malaysia

• Felda Bulkers, Johor, Malaysia

• Maxis Comm, Malaysia

• Time Dot Com, Malaysia

• Wisma Darul Iman, Trengganu

• Singapore Polytechnic

• Indosat, Indonesia

• Nanyang University of Singapore

• Mindef, Malaysia

•Zeal Hi-Tech Sdn Bhd

•Biro Perbadanan Statistik, Indonesia

•Airport Bali, Indonesia

•Atlantis, Indonesia

•Kodeco Oil Rig, Batam, Indonesia

•Pelantar minyak PETRONAS, Malaysia

•UPM, Malaysia

•Kenderaan kebal , ATM.

• Kenaf, LKPN

2006 2007 2008 2009 2009-2010

Market Captured

A New Generation of Aerosol Fire

Suppression System

Manufactured and Designed byManufactured and Designed byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

HUB TECHNOLOGIES (M) SDN BHD

6

Existing Fire Suppression

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

HUB TECHNOLOGIES (M) SDN BHD

Inert gasesArgon, Nitrogen

Water basedHalocarbonHCFC, HFC,CFC

Disadvantages:• Ozone depletion• Damage on property or documents (electrical/electronic)• Damage to property due to corrosive and water residue.• Cause global warming• Danger to human

1st and 2nd Generation

Aerosol

7

A New Generation Aerosol Fire Suppression (3rd Generation)• Fully organic base +(organic admixture and binder)• Malaysian invention and patented• Locally manufactured• Recognised National Product (SJJB)

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

What is AEROHUB

8

Evidence of Aerohub’s effectiveness

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

Why AEROHUB

Hub Video

9

Main Components

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

AEROHUB:Technical Characteristics

Igniter

Combustion Chamber

Insulator

Extinguishing Agent

Coolant

Generator HousingFiltration

10

2 ways of activation

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

Electrical Signalfrom Control Panel(Manual / Automatic)

Thermal- self activation

11

AEROHUB: Method of Activation

Total flooding aerosol gives out smoke-like appearanceHolding time up to 60 minutes.

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

What is AEROHUB

Aerohub aerosol being rapidly generated

Organic coolant

40-45degC

12

Aerohub: Fire Basics

Three Basic elements of fire

Fuel

Heat

O2 O2 O2

O H OH

Oxygen

Heat

Fuel

4th Element of fire -Chain CarriersO, H & OH

Note:O –oxygen ionH- Hydrogen ionOH – Hydroxide ionChain carriers –on surface of fire > propagate the fire to grow

How AEROHUB extinguishes fireHow AEROHUB extinguishes fire

How it works

Fuel

Heat

O2 O2 O2

O H OH

Oxygen

K+

K+

(Potassium + Organic admixture. K+

Chain carrier

O, H & OH

Aerohub aerosol

1.ChemicalRemoval of radicals fire chain carriers

2.PhysicalCooling the fire to a level where the

fire cannot re-ignite.( Lowering the temperature but not by freezing the air or equipment)

How AEROHUB extinguishes fireHow AEROHUB extinguishes fire

How it works

KOH

KO

KOH

The Potassium radicals (K*) bind and remove chain carriers (O, H, OH) Stops propagation of fire => stable products KOH(potash), KO.NO depletion of oxygen

Chain carrierO, H & OH

Removed from the FlameChain

K

K

K

H

HO

O

O

O

Stable Products

KOH

KOH

KO

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

AEROHUB: Benefits• Environment and human friendly

Human friendly No detrimental effects on water, soil, air, climate and animals No ODP – Ozone Depletion Potential No GWP – Global Warming Potential

1.Montreal Protocol: 16th Sept 1987BAN CFCs compound eg. Halon 1301 and Halon 1211 (by 2010)

2.Kyoto Protocol: 11th Dec 1997Reduce greenhouse gas emissions (CO2, CH4, N2O, HFC, PFC and SF6) by at least 5% below 1990 levels in the commitment period 2008 (by2012)

16

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

AEROHUB: Benefits• Cost savings

Minimal maintenance Minimal space requirement No piping required Non Pressurized ( as compared to

those using pressurised system- eg 600psi, the pressure will be transferred to the enclosed room)

No Leaking

17

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

AEROHUB: Benefits

Advance technologyNo immediate and after effects on

electronic & magnetic equipments

No usage of Nitrobutadien (oily residue) or Nitrocellulose

No formation of toxic or corrosive chlorine compounds.

No Sulphur (cause corrosion), potassium chloride.

No Non-Halal Gelatine

Fast discharge time (1-2 seconds) and easy replacement

Safe, reliable and simple Installation

18

Designed byDesigned byHUB TECHNOLOGIES (M) SDN BHDHUB TECHNOLOGIES (M) SDN BHD

AEROHUB: Benefits

Other factors: 100 % Malaysian Product. Save

outflow of Ringgit. 100% Malaysian invention. File in

patent in Malaysia and Registered.

Maintenance – Local support readily available.

Spares – complete set replacement while under warranty.

Lower costs – 15-25% lower than our

competitor.

19

20

Chemical Name Formula Average Results Average Conversion Life Threatening

OxygenO2 20.6vol.% - -

Carbon monoxideCo 1195 ppm 0.12vol.% 0.3 vol.%

Carbon dioxideCo2 0.40 vol % - 20.0 vol%

Nitric oxideNo <1ppm - -

Nitric dioxideNo2 <1ppm - -

Potassium anionK 492mg/m3 - -

Nitrogen trioxideNo3 <23mg/3 - -

pH ScalepH 8.5 - -

Potassium Carbonate K2CO3 879mg/m3- -

AEROHUB : AGIT Human Toxicity test

21

Category AEROHUB DYXXXXO HAXXXX Fxx3& (Fx000)

PYXXXXXX

Patent(MALAYSIA)Process & Formulation

Other countries Other countries Other countries-

Other countries

Organic Admixture YES NO NO NO YES

Organic Binder YES NO NO NO NO

Sulfur PolyclorideCyanide

No unknown unknown YES NO

Contains Non-Halal Gelatine

NO UNKNOWN UNKNOWN UNKNOWN YES

CorrosiveNon-corrosive NO NO NO YES YES

Residue:Oily (Nitrobutadien)

Dry

No Yes No No YES

Usage category OCCUPIED OCCUPIED NORMALLYUNOCCUPIED

NORMALLYUNOCCUPIED

NORMALLYUNOCCUPIED

Space Requirement NO STORAGE AREA

REQUIRED

NO STORAGE AREA

REQUIRED

STORAGE AREA REQUIRED

STORAGE AREA REQUIRED

NO STORAGE AREA

REQUIRED

PRODUCT COMPARISON

22

PRODUCT COMPARISON

23

PRODUCT COMPARISON

24

Category AEROHUB DXXXXXO HXXXXX ErXXX13 PYXXXX

Pipework No piping required

No piping required

YES YES NO

Standby Pressure NOT PRESSURISED

NOT PRESSURISED

HIGH PRESSURE

HIGH PRESSURE

NOT PRESSURISED

Leakage Pressure

Pressure Loss

NO NO YES YES No

Holding Time 45-60 mins 30 mins 5 min. 5 min Uncertain

Maintenance No (MINIMUM)

No (MINIMUM) Yes Yes Minimum

Thermal Shock No No Yes Yes No

PRODUCT COMPARISON

25

Category AEROHUB FM200 (HFC-227ea) CF3CHFCF3

Patent(MALAYSIA)

Process & Formulation USA-

Composition Organic base and organic binder

Heptafluoropropane

Supplier Local (HUB Technologies Sdn

Bhd)

Fike HFC-227ea (DuPont™ FE227™) Kidde FM-200®

Acute Overexposure No Contact with the liquid or cold gas may cause frostbite. Has a central nervous systems effect.

Contains Non-Halal Gelatine NO UNKNOWN

CorrosiveNon-corrosive NO YES

Oily Residue (Nitrobutadien)

No No

Usage category NORMALLYUNOCCUPIED

NORMALLYOCCUPIED

Space Requirement NO STORAGE AREA REQUIRED

STORAGE AREA REQUIRED

PRODUCT COMPARISON

26

Category AEROHUB FM200 (HFC-227ea) CF3CHFCF3

Hazardous Decomposition Products

None Thermal decomposition may producethe following: Hydrogen fluoride, carbonmonoxide and carbon dioxide. (NOT SAFE FOR HUMANS)

Standby Presand

Pressure Loss

NOT PRESSURISEDAND HENCE

NO PRESSURE LOSS

HIGH PRESSURE – stored as liquid and pressurized with nitrogen

at 42bar ((609 psi)

Potential Health Effects NOOverexposure to HFC-227ea may cause suffocation, if air is displaced by vapors, and irregular heart beat with a strange sensation in the chest, feeling of fainting, dizziness, weakness, sometimes progressing to loss of consciousness and death.HFC-227ea may cause frostbite if liquid or escaping vapor contacts the skin and the eyes.

Holding Time45-60 mins 10 min

MaintenanceNo (MINIMUM) Yes

Thermal Shock No Yes

PRODUCT COMPARISON

27

Category Ozone Depleting Potential ODP

GWP Global Warming

Potential ( C02=1)

Atmospheric lifetimes (yrs)

Extinguishing concentration

%V.V. g/m3

Mechanism of fire suppression

AEROSOL BASED0 0 0 - Physical

and chemical

HFC BASED:FE25, FM200, FE13

0 FE13 -11700

FM200- 2900

36.4 264

7-18 chemical

CFC BASEDHalon 1301

10 5600 65 5 chemical

PFC BASED:Naf S 111

0.036 1450 12 11.9 chemical

NATURAL GASES:ArgoniteArgotecInergen

CO2

0001

0001

26400

120

16-18 38 37.5 50

Physical

WATER BASED 0 0 0 0 physical

CHEMICAL POWDER

0 0 0 chemicalOr physical

ENVIRONMENTAL DATA

28

AEROHUB Certification

AGIT FRANCE

AEROHUB Certification

BOMBA MALAYSIA

AEROHUB Certification

AEROHUB Certification

AEROHUB Certification

AEROHUB Certification

In collaboration with Standard Malaysia

AEROHUB Certification

DINAS KEBAKARANINDONESIA

AEROHUB Certification

SINGAPOREC IVILD EFENCEF ORCEHQ SINGAPORE CIVIL IIEFENCE FORCE

9f Ubi Avenue 4 Singspore 40882?Website:h ttp//:www.scdfg. ov.sg

Ref No : CON1C0007003108PROPOSAL:F IRE SI.JPPRBSSIOSNY STEM (GENERAL ENQUIRES)RECORD OF CONSULTATION

Item 1: Fire suppressions ystemt o be used in an occupied space in lieu of sprinklersystem. How to obtain approval or no objection by SCDF on product oSed.-

Comment: ComplywithNFPA200l'

A PROUD MEMBER OF THE HOME TEAMSINGAPORE CIVIL DEFENCE F ORCEIIQ SINGAPORE CTWL DEFENCE FORCE91 ubi Avenue 4 SingaPore 4A8827Websiteh: ttP//:wwwscdfg. ov'sg ffibPlease quote our ref. ng' in all future cotrespondences

AEROHUB Certification

AEROHUB Certification

AEROHUB Models availableAEROHUB Models available

GENERATOR SPECIFICATIONS :

• Generator housing and all internal components are made of Stainless Steel or Mild Steel to suit the environment.

• Temperature : Operates with +50 to -50 °C

• Humidity : Operates up to 96% RH

• Warranty : 2 years for manufacturer’s defect

Model

SS/MS 50

SS/MS 30

SS/MS 20

SS/MS 10

SS/MS 5

SS/MS 2.5

Room

Volume50m3 30m3 20m3 10m3 5m3 2.5m3

Ketenteraan

Petroleum & Gas

Telekomunikasi

Pengangkutan Penjanaan Kuasa

Infrastruktur

Pelantar MInyakKilangFasiliti Penyelidikan Bunker

AmunisasikenderaanJet PenerbanganKereta Kebal

Pusat Kawalan DataBilik KomputerTingkat tinggiBilik PenjanaBilik UPSHospitalUniversitiSub Stesen

Bilik AHU Bilik HV Bilik LVKotak DB

KapalKeretaKeretapiBas

Stesen PenghantaranStesen RadioPertukaranPusat Kawalan Data

a copyright and trademark of Hub Technologies

Industry Analysiss

• Generated revenue for fire suppression industry is RM 70 mill in 2010.• Market growth estimated – RM0.6 billion in 5 yrs

Total Fire Suppression Market size in Malaysia in RM (millions)

2011(Total RM87mil) 2015 (Total RM151mil)

Source: Jab BOMBA Malaysia and Takaful Malaysia

a copyright and trademark of Hub Technologies

Industry Analysis

Market share •Asia Pacific 33%• Middle East 33%• Others 34%

Total Fire Suppression Market size outside Malaysia in RM (millions)

2011 2015

AEROHUB Installation

Blower Room Generator RoomCeiling Flush Mounting

Switchgear Room MCC Room

Inside Engine