FLOOR STANDING TYPE
COOLING ONLY 50Hz
AIR COOLED PACKAGEDAIR CONDITIONERS
Suitable for
factories
DUCT CONNECTION TYPEDIRECT AIR BLOW TYPE
PLXPMT1726
FLOOR STANDING TYPE
FLOOR STANDING TYPE
Product Line UpCooling only
50,00014.7
60,00017.6
100,00029.3
80,00023.5
12,600 15,100 25,20020,200
5 1086kW
Capacity 1, 2
Btu/hkcal/h
RUR10NY1RUR08NY1RUR05NY1 RUR06NY1
RUR10NY1
HP
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
OUTDOOR UNIT
FVGR08NV1FVGR05NV1 FVGR06NV1 FVGR10NV1
FVPGR10NY1
DIRECT AIR BLOW TYPE
DUCT CONNECTION TYPE
FLO
OR
STA
ND
ING
TY
PE
HFC R410A Line Upfor Factories and OfficesWe have entered an era in which being recognized as an environmentally responsible corporate citizen has taken utmost importance.
Even when selecting air conditioners, a new model featuring HFC R410A refrigerant could be the perfect step in promoting your corporate image.
1
HFC R-410A Line Upfor Factories and OHFC R-410A Line Upfor Factories and O
Even when selecting air conditioners, a new model featuring R-410be the perfect step in promoting your corporate image.Even when selecting air conditioners, a new model featuring HFC R-410refrigerant could be the perfect step in promoting your corporate image.
We have entered an era in which being recognized as an environmentally responsible corporate citizen has taken utmost importance. We have entered an era in which being recognized as an environmentally responsible corporate citizen has taken utmost importance.
FLOOR STANDING TYPE
Product Line UpCooling only
50,00014.7
60,00017.6
80,00023.5
12,600 15,100 20,200
5 86kW
Capacity 1, 2
Btu/hkcal/h
RUR08NY1RUR05NY1 RUR06NY1
HP
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
OUTDOOR UNITDimensions Page 15,16
FVGR08NV1FVGR05NV1 FVGR06NV1
DIRECT AIR BLOW TYPE
DUCT CONNECTION TYPE
FLO
OR
STA
ND
ING
TY
PE
Specifications Page 5Dimensions Page 11
Specifications Page 5Dimensions Page 12
DIRECT AIR BLOW TYPE
Direct air blow from indoor unit with plenum
Comfortable factory air conditioning using multiple indoor units installed in accordance with the space. Installation is next to walls, so units will not affect the factory layout even if the changes are made.
Nice, cool air in the factory or in the cafeteria
50Hz
160,00046.9
180,00052.8
200,00040,300 45,400 50,400
58.61815 20
RUR15NY1 RUR18NY1 RUR20NY1
FVPGR15NY1 FVPGR18NY1 FVPGR20NY1
DIRECT AIR BLOW TYPE
Direct air blow from indoor unit with plenum
Comfortable factory air conditioning using multiple indoor units installed in accordance with the space. Installation is next to walls, so units will not affect the factory layout even if the changes are made.
Nice, cool air in the factoryor in the cafeteria
ficesfices
50Hz
160,00046.9
120,00035.2
180,00052.8
200,00040,30030,200 45,400 50,400
58.613 1815 20
RUR13NY1 RUR15NY1 RUR18NY1 RUR20NY1
FVPGR13NY1 FVPGR15NY1 FVPGR18NY1 FVPGR20NY1
2
DUCT CONNECTION TYPE
FLOOR STANDING TYPEDIRECT AIR BLOW TYPE
AIR COOLED PACKAGED AIR CONDITIONERS
RUR10NY1FVGR10NV1
RUR10NY1FVPGR10NY1
Enhanced varieties of factory modification and optional accesories
Standard modelFactory modification
Auto restart
Floor Standing Type
Fac
tory
Mod
ifica
ion
Direct Air Blow
–
–
–
–
–
Central control adaptor kit (external terminal for ON/OFF , abnormal)1
Opt
ion
Modify wiring for central control adapter kit (DAT107A55) installation
Change fan motor and pulley
Discharge grill plenum chamber
Side discharge grillon discharge plenum chamber
Lower drain pan
Front suction high efficiency filter chamber
Suction grill for front suction high efficiency filter chamber
Fresh air inlet
Rear suction
Drain pump
LCD remote controller2
intelligent Touch Controller2
Central remote controller2
Unified ON/OFF controller3
Schedule timer3
Remote sensor (thermistor for suction air)3
Remote controller
Remote sensor(Thermistor for suction air)
All fresh air application
Low outdoor temp.15ºC application and long pipe 70m application
Front suction base flange for front suction high efficiency filter chamber
Contact sales for more infomation
Note: 1Wiring modification is needed on floor stand model to connect with central contr2Need to use central control adapter kit for option connection.3Central control adapter kit and LCD remote controller is necessary for option co
Equipped with scroll compressor for quiet operation
Smooth running, low vibration, low operating sound.
Quiet Operation
Outdoor unitSound level
59 dB
380V 415V
RG125AUY1RUR05NY1
59 dB
60 dB
60 dBRG125AUY1RUR06NY1
3
DUCT CONNECTION TYPE
FLOOR STANDING TYPEDIRECT AIR BLOW TYPE
AIR COOLED PACKAGED AIR CONDITIONERS
RUR10NY1FVGR10NV1
RUR10NY1FVPGR10NY1
Enhanced varieties of factory modification and optional accesories
Standard modelFactory modification
Auto restart
Floor Standing Type
Fac
tory
Mod
ifica
ion
Direct Air Blow
DuctConnection
Type
Duct Type
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Central control adaptor kit (external terminal for ON/OFF , abnormal)1 DAT107A55
Opt
ion
–
Modify wiring for central control adapter kit (DAT107A55) installation
Change fan motor and pulley
Discharge grill plenum chamber
Side discharge grillon discharge plenum chamber
Lower drain pan
Front suction high efficiency filter chamber
Suction grill for front suction high efficiency filter chamber
Fresh air inletFresh air inlet
Rear suction
Drain pump
BRC1C62LCD remote controller2
DCS601C51intelligent Touch Controller2
DCS302CA61Central remote controller2
DCS301B61Unified ON/OFF controller3
DST301BA61Schedule timer3
KRCS01-1Remote sensor (thermistor for suction air)3
BRC1NU64Remote controller
Remote sensor(Thermistor for suction air)
All fresh air application
Low outdoor temp.15ºC application and long pipe 70m application
Front suction base flange for front suction high efficiency filter chamber
Contact sales for more infomation
Note: 1Wiring modification is needed on floor stand model to connect with central control ADP kit.2Need to use central control adapter kit for option connection.3Central control adapter kit and LCD remote controller is necessary for option connection.
Equipped with scroll compressor for quiet operation
Smooth running, low vibration, low operating sound.
Quiet Operation
Outdoor unitSound level
59 dB
380V 415V
RUR05NY1
59 dB
60 dB
60 dBRUR06NY1
DurabilityHeat exchange fins provided with anti-corrosion treatmentTo achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
(Applies to all outdoor units)
(Applies to RUR05N/06N)
Previous 20HP outdoor unit
Installation space is saved thanks to a more compact outdoor unit. This also makes it easier to install.
Space savings
RUG10AUY1 X 2RUR20NY1
(20HP)
NEW
2,560mm690mm
1,240mm765mm
space savedcompared to
previous model
53%
Refrigerant pre charged for up to 7.5 metres
Design flexibilityDesigned for long refrigerant piping. 50 m maximum length and 30 m maximum level difference to cover medium- and large-scale building needs.
Outdoor unit roof installation possible for plenty of leeway.
Allowable refrigerant pipe length and level difference
Max. leveldifference Pre-charged 1 Max. length
30 m7.5 m 50 m(Equivalent length 70 m)
Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the indicated length.
4-direction piping affords more freedom of layoutPiping can be run from the front, bottom, right or rear surface according to how the unit is installed.
In case of RUR08–20N, piping can be drawn out in two directions-front, and under side.
Max. length
Max. level difference
RUR05NY1-20NY1
Easy operationDigital remote control comes standard with indoor unit.
Temperature setting is possible by button operation. The set temperature is conveniently displayed on the LED.
1453
6789
210
1
2
3
5
6
7
89
Note.1
Note.1
4
1 Power
3 Temperature setting
2 Temperature scale
4 Mode setting
5 Next setting
6 Fan indicator lamp
7 Cool indicator lamp
9 Compressor 1 indicator lamp
10 Temperature sensor
8 Compressor 2 indicator lamp
1 On/Off button
3 Temp. setting up
2 Fan button
4 Temp. setting down
5 Mode button
6 LED display
7 Compressor operation lamp.
8 Fan operation lamp.
9 Cool operation lamp.
Note.1 It cannot be used for FVPGR10–20NY1
(Standard accessory)Floor standing type
(optional accessory)Duct type
4
lvory White
14 to 25
21 to 46
Ivory white Hermetically sealed scroll type
4.5
RUR10NY1
5HP
12,600
14.7
RUR05NY1
50,000
421,480
421,480
1,870X750X51090 90
2.5 (Charged for 7.5 m)
1,345X900X32092 105 203 206
8HP
20,200
23.5
RUR08NY1
80,000
1,91054
1,870X950X510107
4.5 (Charged for 7.5 m)
1,680X930X765
10HP
25,200
29.3100,000
2,830
59/54/50 59/54/50 60/56/51 61/57/52
80
1,870X1,170X510143
6.0 (Charged for 7.5 m)
30
50 (equivalent length 70 m)
Cooling capacity 1, 3 kWBtu/hkcal/h
kWPower consumption 1
ModelName
Indoorunit
Indoor unitOutdoor unit
Sound level (H/M/L) 2 dBADirect Drive 3 SpeedDrive
Refrigerant charge (R-410A) kgSound level 2 dBA
Dimensions (HXWXD) mmMachine weight kg
Machine weight kg
Operation range °CDB
Operation range °CWB
RefrigerantPiping
mmIndoor unit
Max. installation level difference
mm
Outdoor unit
mmLiquid Gas
Liquid Gas
Air flow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Dimensions (HXWXD)
Colour
mm
Max. interunit piping length mm
Power supply 380–415 V, 50 Hz, 3 Phase, 4 Wires
kWMotor outputCompressor Type
POLYOL ESTERDAPHNE FVC68D1.4 1.8 3.3LCharge
Refrigerantoil
Model
Note : 1Rated cooling capacities are based on the following conditions : Return air temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.3Capacity includes indoor fan motor heat.
o/ 9.5 (Brazing)o/ 19.1 (Brazing)
o/ 9.5 (Flare)o/ 19.1 (Flare)
o/ 12.7 (Brazing)o/ 22.2 (Brazing) o/ 28.6 (Brazing)
o/ 12.7 (Flare)o/ 22.2 (Brazing) o/ 28.6 (Brazing)
mmmm
RefrigerantPiping
mmIndoor unit mm
Outdoor unit
mmLiquid Gas
Liquid Gas
mm
mmmm
PS 1B Internal thread
lvory White
Ivory white Hermetically sealed scroll type
9.0
29.3100,000
802,830
1,740X1,170X510150
6.0 (Charged for 7.5 m)
1,680X930X765206 243 319 322 329
46.9160,000
4,240120
1,680X1,240X765
50,400
58.6200,000
5,720162
180 240
30
50 (equivalent length 70 m)
Cooling capacity 1, 3 kWBtu/hkcal/h
Indoorunit
Sound level 2 dBAExt. Static Pressure Pa(mmH2O) 15
Belt DriveDrive
Refrigerant charge (R-410A) kg
Dimensions (HXWXD) mmMachine weight kg
Machine weight kg
Operation range °CDB
Operation range °CWB
Max. installation level difference
Air flow rate (H) m3/mincfm
Outdoorunit
Colour
Dimensions (HXWXD)
Colour
mm
Max. interunit piping length mm
Power supply 380–415 V, 50 Hz, 3 Phase, 4 Wires
kWMotor outputCompressor Type
o/ 12.7 (Brazing)o/ 28.6 (Brazing)
o/ 12.7 (Flare)o/ 28.6 (Brazing)
PS 1B Internal thread
RUR20NY1
10HP
RUR10NY1
15HP
RUR15NY1
20HPModelName
Indoor unitOutdoor unit
Fan
Fan
----------
6HP
RUR06NY1
o/ 26.0 (Hole)
----------
POLYOL ESTER3.3 5.0 6.5
13HP
RUR13NY1
18HP
RUR18NY1
LChargeRefrigerantoil
Model
15,1005.5 8.6 11.26.4
Starting currentPower factor
17.660,000
1,870X750X510
9.0 10.4 14.4 18.9Running current A72.7 80.9 118.2 135.0A88.2 88.8 85.9 85.5%
Starting currentPower factor
Running current A
3.5 (Charged for 7.5 m)59 60 6159
dBA380V415V 60 61 6260
30,200
35.2120,000
1,870X1,170X720
4.5 (Charged for 7.5 m)
45,400
11.4 17.8
61 62 6362 63
52.8180,000
19.2 29.0 40.424.3 34.6
% 85.7 88.6 88.688.5 88.4A 129.5 130.3 146.3118.0 143.4
1,870X1,470X720
8.0 (Charged for 7.5 m)
o/ 15.9 (Brazing)o/ 34.9 (Brazing)
o/ 15.9 (Flare)o/ 34.9 (Brazing)
FVGR05NV1 FVGR08NV1 FVGR10NV1
FVPGR10NY1 FVPGR15NY1 FVPGR20NY1
FVGR06NV1
FVPGR13NY1 FVPGR18NY1
4.5 6.7 9.0
5.0+5.0 6.7+6.7 7.5+7.5 9.0+9.0
Sound level 2 dBA 61 62 6361dBA
380V415V 62 63 64
636462
14 to 25
21 to 46
DUCT CONNECTION TYPE
DIRECT AIR BLOW TYPEFLOOR STANDING TYPE
FLOOR STANDING TYPE
25,200 40,300
kWPower consumption 1 24.814.9 21.2
Drain
Drain
Drain
Drain
5