assured contactless seriesuts-10-2t p28 bts-2-1t p29 stmb10 p26 stfb12 p26 ax1 p27 ax4 p27 hs1 p24...
Post on 12-Aug-2020
3 Views
Preview:
TRANSCRIPT
Assured
Reliable
Contactless
Assured
Reliable
Contactless
Contactless Series Contactless Series
Magnetic Proximity Switches P.1 ~
Ferrous Proximity Switches P.11 ~
Contactless Touch Switches P.15 ~
Switch Catalogue
-Contents- ● Magnetic Proximity Switches……P1~4
● “Magbase” for High Accuracy Positioning……P7~8
● “Mag” for Magnetic Proximity Switches……P5~6
AH002-S / AH002-D
P2
AH003-S / AH003-D
P2
AH004 / AH004H
P2
AH013-S
P3
AH024
P3
AHM024
P3
AH023
P3
AH012-BS
P3
CAA-N1CAB-N1CAP-P1CAP-N1 P4
AG001
P7
AG001H
P7
AG002
P8
AG002H
P8
AG003
P8
AG003H
P8
AG004
P8
AG004H
P8
AG011/AG011-K
P8
AG001K
P5
AG001KH
P5
AG002K
P6
AG002KH
P6
AG003K
P6
AG003KH
P6
AG004K
P6
AG004KH
P6
AG0304
P6
AG05015
P6
● Cable Options
● Switches for Air Cylinders……P9~10
● Ferrous Proximity Switches……P11~12
● Door Sensors……P13~14
● Contactless Touch Switches……P15~29
UTS-10-2T
P28
BTS-2-1T
P29
STMB10
P26
STFB12
P26
AX1
P27
AX4
P27
HS1
P24
STB30
P25
STM14
P25
STR10
P25
PM4
P21
PM5
P21
PM6
P22
STF15
P23
STS8
P23
STM10-S/STM10-D
P19
STM8
P19
STM8L
P20
STM6
P20
MR1A-HU
P17
MS1A-HUE
P17
N308
P18
N6
P18
P16
P13
AR001/AR001(B)
ADH02/ADG02/ADG02X/ADH02X
P12
AR011/AR011(B)
P12
AR101/AR101(B)
P12
AR002/AR002(B)
P12
AH006
P10
AH007
P10
AH008
P10
● Cable connector
1
Circuit system CNC-3
Circuit system CNC-2Circuit system CNC-1
Circuit system CNC-5
Circuit system CNC-4
Circuit system CNC-6
DC5 ~ 24V
Output 1
Output 2
Output 1
Output 2
■AH002-D
DC5 ~ 24V
■AH002-S
DC5 ~ 24V
■AH004(H) ■AH023-S ■AH003-S ■AH013-S
DC5 ~ 24V
■AH003-D
DC5 ~ 24V
■AH024 ■AHM024 ■AH023
■AH012-BS
High sensitivityHigh precisionPolarity selection
“Mag” “Magbase”
Other magnetic objects
Hall-effect magnetic
sensor
Sensitive proximity action
Mag
DC5 ~ 24V
Sensing pole
Magnetic sensitivity
Response time
Supply voltage
Maximum supply current
Output form
Maximum output current
Cable length
Voltage resistance
Insulation resistance
Degree of protection
General specifications
Magnetic Proximity Switches
Connection examples(circuit diagrams)
Features
S-pole ( ) 2.5 ~ 4 mT (25 ~ 40 Gauss)
5μ sec max.
DC 5 ~ 24V
8 mA per sensing circuit
NPN Normally Open
( )
Standard length :1m
2×1011Ω min. against case
-20 ~ +85℃
20 ~ 95% RH
( ) Equivalent to IP67
Note: Standard sensing zone is S-pole side, and the color of 3-wire cable is gray for the standard type. The cable color is black for N-pole type(with some exceptions).
Normally Closed or PNP output available with optional cable
Amplifiable to 80mA with optional cable (refer to P4)
Mechanism
Although our products are designed to ensure safety and address risks, in case that a switch malfunction or failure is expected to lead to serious risks to life or property, please be advised to expand further safety gear such as the incorporation of dual circuit.
(1)Prevention of reverse connection…Please observe the circuit diagrams so as to ensure correct connections. Reverse connection of power supply is strictly prohibited.
(2)Relay drive…When driving a relay, please connect a freewheel diode in parallel.
(1)Clamping torque…Please observe the value of torque designated for each switch.(2)Cable handling… Do not subject the connecting part between cable and switch-head to tension(tensile strength as 20N at max.,
the bending radius as 7mm at least).
● Precautions for safety use
● Correct wiring
● Mounting the switch
Precautions
ON, when sensing object approaching
Measures for condensation / in-water operation to be consulted separately
Sensing circuit
Sensing circuit
Sensing circuit
Sensing circuit
Sensing circuit
Sensing circuit
Sensing circuit
Sensing circuit
LoadLoad
Load
Load
Load
Load
LoadLoad
Brown
Brown
Black
Black
Blue
Blue
Brown
Black
Blue
Green Red
Red
Brown
Black
Blue
Red
Brown
Black
Blue
Red
Orange
Brown
Black
Blue
Orange
N-pole detection is optionally available with some exceptions
(refer to P4)
1,000V AC, for 1 min. between current-carrying parts and case
Operating temperature range
Operating humidity range
15 mA per sensing circuit
2
Do not drive a M3 screw in too tightly. It is recommendable to bond the screw in order to prevent loosening.
18
10.5 5.5
5 4.8
M306.2
9.7
21
95.5 5
Mounting side
Sensing face
Sensing face
Sensing face
Sensing face
Sensing face
Sensing face
18
Indicator
Sensing face
φ3(max.)
φ3(max.)
6
2.5 5.6
2-φ2.2 φ0.9×3
3.5
1.5 8
8.6
12
4.3 6.6
2-φ2.2
4.22.3
1.5 8
7.8
12
5.8
5.4
φ2.6
5.4
5.6
4.70.4 3.3
02.2
5.6
10.8
M2.5
6.2
5
Mounting bracket-1 Mounting bracket-2
φ2.6
5.4
5.6
0.4
3.3
9.9
10.8
M2.5
7.5
2.8
Model Dimensions(mm) Specifications
AH002-S / AH002-D-S:Single/-D:Double
-S:Single/-D:Double
Case
Mounting
Indicator
Circuit diagram
GF reinforced PBT : Green
2-M2 Screw fastening torque 0.3N・m
Upward, Sideway(Refer to the dimensions)
Not included
φ 0.9 wire ×3, Length 0.3m
CNC -1(Refer to P1)
Case
Mounting
Built-in switch
Indicator
Circuit diagram
GF reinforced PBT : Black
Dedicated mounting bracket
Not included
Single:3-wire, gray Double:4-wire, black
Single:CNC -1(Refer to P1) Double:CNC -6(Refer to P1)
Case
Mounting
Built-in switch
Indicator
Circuit diagram
GF reinforced PBT : Green
M3 ×0.5 Screw fastening torque 1N・m
Single:3-wire, gray Double:4-wire, black
Single:CNC - 3(Refer to P1) Double:CNC - 5(Refer to P1)
* When ordering, please indicate either“Mounting Bracket-1” or “Mounting Bracket-2”.
AH004
AH004H
Lineup of Magnetic Proximity Switches
AH003-S / AH003-D
AH004 / AH004H
Cable specifications
Cable specifications
Cable specifications
Magnet sensing direction
Single:AH002-S Double:AH002-D Differential distance:1.5 ± 0.3(mm)
Single:Red Double:Output 1…Green,
Output 2…Red
Single: AH003-S Double: AH003-D Differential distance : 1.5 ± 0.3(mm)
3
The clamping torque for M7 nut is 0.3N・m. Do not clench the nut too tightly. It is recommendable to bond the screw in order to prevent loosening.
The clamping torque for M9 nut is 0.5N・m. Do not clench the nut too tightly. It is recommendable to bond the screw in order to prevent loosening.
The clamping torque for M12 nut is 2N・m. Do not clench the nut too tightly. It is recommendable to bond the screw in order to prevent loosening.
The clamping torque for M9 nut is 0.5N・m. Do not clench the nut too tightly. It is recommendable to bond the screw in order to prevent loosening.
(16)
26
38
1214
Sensing face
M12×1 Cable φ2.8×1m
Nut 3t
Indicator
(11.4)
M7×0.75
Sensing face
21
102
10 φ6.2
Cable φ2.8×1m
(13.6)
Sensing face
Cable φ2.8×1m
M9×1Nut 2t
25
Indicator1412
(13.6)
Sensing face
Cable φ2.8×1m
M9×1Nut 2t
25
Indicator1412
(13.6)
Sensing face
Cable φ2.8×1m
M9×1Nut 2t
25
Indicator1412
Case
Mounting
Indicator
Circuit diagram
SUS303 Screw type
M9×1 Screw fastening torque 8N・m
Refer to below
Red
3-wire, gray (Black for N-pole type)
CNC-2(Refer to P1)
Case
Mounting
Indicator
Circuit diagram
GF reinforced PBT : Black
M12 ×1 Screw fastening torque 2N・m
Refer to below
Red
3-wire, gray (Black for N-pole type)
CNC-2(Refer to P1)
Case
Mounting
Indicator
Circuit diagram
Response speed
GF reinforced PBT : Green
M9 ×1 Screw fastening torque 0.5N・m
Red
3-wire, black
CNC - 4(Refer to P1)
90μ sec max.
DC 24V 80mA
Case
Mounting
Indicator
Circuit diagram
GF reinforced PBT : Black
M9×1 Screw fastening torque 0.5N・m
Refer to below
Red
3-wire, gray (Black for N-pole type)
CNC-2(Refer to P1)
Case
Mounting
Indicator
Circuit diagram
GF reinforced PBT : Gray
M7×0.75 Screw fastening torque 0.3N・m
Not included
3-wire, gray (Black for N-pole type)
CNC-1(Refer to P1)
Model Dimensions(mm) Specifications
AH013-S
AH024
AHM024(All SUS screw type case)
AH023
AH012-BS(High output type)
Model Magnetic sensitivity
AH024 2.5 ~ 4 mT
AH024H(High sensitivity) 0.8 ± 0.15 mT
AH024HN(High sensitivity・N-pole) 0.9 ± 0.15 mT
Model Magnetic sensitivity
AH023 2.5 ~ 4 mT
AH023H(High sensitivity) 0.7 ± 0.15 mT
AH023HN(High sensitivity・N-pole) 0.8 ± 0.15 mT
Model Magnetic sensitivity
AHM024 2.5 ~ 4 mT
AHM024H(High sensitivity) 0.8 ± 0.15 mT
AHM024HN(High sensitivity・N-pole) 0.9 ± 0.15 mT
Cable specifications
Cable specifications
Magnetic sensitivity
Cable specifications
Cable specifications
Magnetic sensitivity
Cable specifications
Magnetic sensitivity
Maximum load capacity
4
Freewheel diode
Model Dimensions(mm) Connection examples(circuit diagrams)
22
φ2.8
29.5
24
28
Sensor side
Sensor side
Sensor side
Sensor side
2.6
7
7
CAA-N1(Add indicator)
CAB-N1(N.O.→N.C.)
CAP-P1 (NPN→PNP)
CAP-N1
Cable Options Connected along the cable pathway of ASA sensors or switches, the cable optionsavails current amplification and conversion of signals.
CAA-N1
CAB-N1
CAP-P1
CAP-N1
SensorBrown
Black DC12 ~24V
Blue
CAA-N1
Load
Brown
BlackRed
DC12 ~ 24V
Blue
CAP-N1
Indicator
Indicator
Indicator
Brown
Black DC12 ~24V
DC12 ~24V
Blue
CAP-P1
Red
Freewheel diode
Sensor
Sensor
Sensor
Sensing circuit
Brown
Black
Blue
CAB-N1 Freewheel diode
Signal inversion
New Series
Specifications
Features
Lineup of Cable Options
Sensing circuitSensing circuit
Sensing circuit
Load
Load
Load
Mode Function Output form IndicatorMaximum load
N.O. : Normally Open N.C. : Normally Closed
Add indicatorNPN N.O.
DC24V / 15mA
Red LED
N.O.→N.C. conversion Current amplification
NPN N.C.
DC24V / 80mA (freewheel diode embedded)
NPN→PNP conversion Current amplification
PNP N.O.
DC24V / 80mA (freewheel diode embedded)
Current amplificationNPN N.O.
DC24V / 80mA (freewheel diode embedded)
5
Magnetic property
con tac t l e ss sw i t ch
Gap h(mm)
Model Dimensions(mm)
2-φ3.2×13.61t
36
16
5
8
14.6
7.5
3
2-φ3.2×13.61t
36
16
5
8
4.59.6
12.6
-15 -10 -5 5 10 15
1mT
2mT
3mT
30
25
20
15
10
5
0
Gap h(mm)
0
Sensing area
Distance x(mm)
30
25
20
15
10
5
0
1mT
2mT
3mT
-15 -10 -5 5 10 150
Sensing area
Distance x(mm)
Sensing area
Mag
S
N
Magnetic field
Magnetic proximity switch
“Mag”and“Magbase”are magnetic objects designed suitable for Magnetic Proximity Switches.
The combination of Magnetic proximity switch and “Mag”
AG001K
AG001KH
Features
Lineup of “Mag”
SummaryIn case of combination of Magnetic proximity switch
and“Mag”, the sensing area is globular shape as
indicated in the figure. Through this shape, magnetic
proximity switches have stable position sensing
ability against any directional approaching. The
extent of sensing area is fixed by choice of Mag (that
is magnetic intensity)and Magnet proximity switch
(that is magnetic sensitivity).
Model“AG0304”and“AG05015”are bare rare-earth
magnets. They are suitable for mounting on a
compact-sized unit with less installation space.
Magnet property is measured under condition that the sensing face keeps being parallel to x-axis.
“Mag”for Magnetic Proximity Switches
Mag : wider and longer sensing area Magbase : high accuracy sensing
6
Magnetic property
20
15
10
5
0
1mT
2mT3mT
Gap h(mm)
-15 -10 -5 5 10 150
Sensing area
Model Dimensions(mm)
con tac t l e ss sw i t ch
Oval hole for 2-M2.5,2.6
1411
4.8
09
3.40.8
6.4
18
16.7
93
6.2
4.86.23.8
2.7
8.7
14
18
6.2
0.8
2-2.2×4
1.3
2.9 13
3.4
7
5.4 7.4
Magnetic center
φ3
4
2-2.2×4
1.3
3.5 13
2.8
7
4.8 6.8
Magnetic center
φ5
1.5
2-φ3.2×7.8
1t
23
10
8
14.6
7.5
3
5
2-φ3.2×7.8
1t
23
10
58
4.59.6
12.6
Gap h(mm)
10
8
6
4
2
0
-2-4-6 2 4 60
Sensing area
2mT
1mT 3mT
Distance x(mm)
16
14
12
10
8
6
4
2
0-2-4-6-8 2 4 6 80
Sensing area
1mT
3mT
2mT
(No orientation)
Gap h(mm)
Distance x(mm) Distance x(mm)
16
14
12
10
8
6
4
0
Gap h(mm)
-2-4-6-8-10 2 4 6 8 100
Sensing area
2mT
3mT
1mT
Distance x(mm)
16
14
12
10
8
6
4
0
Gap h(mm)
-2-4-6-8-10 2 4 6 8 100
Sensing area
1mT
2mT
3mT
Distance x(mm)
Distance x(mm)
1mT2mT
0
10
20
30
2010-10-20
3mT
0
Gap h(mm)
Sensing area
AG002K
AG002KH
AG003K
AG003KH
AG004K
AG004KH
AG0304
AG05015
AG0304 AG05015
Note:Please keep the product away from such objects / equipments which may be harmed by strong magnetism.
Lineup of “Mag”
7
Model Dimensions(mm) Magnetic property
con tac t l e ss sw i t ch
AH002-D Double switch
Magbase
Output BOutput ADifferentiate distance
Case(shown in section)
Iron plateMagbase
Magnetic field Magnetic proximity switch
SN
NS
NS
SN
Sensing area
Magnet
Gap
2-φ3.2×13.61t
36
16
5
8
14.6
7.5
3
2-φ3.2×13.61t
36
16
5
8
4.59.6
12.6
20 18 16 14 12 10 8 6 4 2 0-14 -12 -10 -8 8 10 12 140
0.5mT
1mT
1mT
0.5mT
Gap h(mm)
Distance x(mm)
9
8
7
6
5
4
3
2
1
0-11-12 -10 -9 -8 8 9 10 11 120
2mT
3mT
4mT
4mT
3mT
2mT
Gap h(mm)
Distance x(mm)
Sensing area Sensing area
AG001
AG001H
The combination of Magneticproximity switch and “Magbase”
As shown in the figure,“Magbase” is an array of 3 magnets
disposed on an iron plate with each polarity alternated(patented).
By using“Magbase”instead of“Mag”, the effect of gap
change on the sensing area can be minimized. As the
arrayed magnets make the magnetic gradient neighboring
the boundary of the sensing area dense,“Magbase” is
capable of an extraordinary precise repeatability of the
operating point compared to“Mag”.
Since magnetic proximity switches are small in size and
have no magnetic interaction between switches, they can be
closely disposed. Taking the advantages of these benefits,
a double switch incorporates a switch with dual operational
points in a single casing.
A double switch can detect both the origin point of a servo
system and overrun, thus contributive to a downsizing of
machine unit and a reduction in assembling cost.
“Magbase” forHigh Accuracy Positioning
Patented in Japanand the US
“Magbase”readily realized an extraordinary precise repeatability never before possible with traditional proximity sensors and magnetoresistance elements.
Lineup of “Magbase”
Model “AH002-D”, “AH003-D”
8
Model Dimensions(mm) Magnetic property
con tac t l e ss sw i t ch
Mounting hole for M4 sideways adjustable within the range of ±3mm
956
30
90
AG011
AG011-K(Powerful type)
Center of the upper surface of “Magbase” Sensing face
h+
X+
2-φ3.2×7.8
1t
23
10
8
14.6
7.5
3
5
2-φ3.2×7.8
1t
23
10
5
8
4.59.6
12.6
Oval hole for 2-M2.5, 2.6
1411
4.8
09
3.40.8
6.4
18
16.7
93
6.2
4.86.23.8
2.7
8.7
14
18
6.2
0.8
2-2.2×4
1.3
2.9 13
3.4
7
5.4 7.4
Magnetic center
Magnetic center
2-2.2×41.3
3.5 13
2.8
7
4.8 6.8
40
30
20
10
00-25-30-35-40 40353025
2mT
3mT
4mT
4mT
3mT
2mT
Gap h(mm)
Distance x(mm)
70
60
50
40
30
20
10
00-30-40-50 504030
0.5mT
1mT
1mT
0.5mT
Gap h(mm)
Distance x(mm)
Sensing areaSensing area
60
50
40
30
20
10
00-20-25-30-35 35302520
0.5mT
1mT
1mT
0.5mT
Gap h(mm)
Distance x(mm)
40
30
20
10
00-15-20-25-30 30252015
2mT
3mT
4mT
4mT
3 mT
2mT
Gap h(mm)
Distance x(mm)
Sensing area Sensing area
5
4
3
2
1
0-3 -2 -1 1 2 30
0.5mT
1mT
1mT
0.5mT
Gap h(mm)
Distance x(mm)
3
2
1
0-3 -1-2 21 30
2mT
3mT
4mT
4mT
3mT
2mT
Gap h(mm)
Distance x(mm)
Sensing area Sensing area
12 11 10 9 8 7 6 5 4 3 2 1 0
-7-8 -6 -5 -4 4 5 6 7 800.5mT
1mT
1mT
0.5mT
Gap h(mm)
Distance x(mm)
6
5
4
3
2
1
0-6 -5 -4 -3 3 4 5 60
2mT
3mT
4mT
4mT
3mT
2mT
Gap h(mm)
Distance x(mm)
Sensing area Sensing area
12 11 10 9 8 7 6 5 4 3 2 1 0
-6-7 -5 -4 -3 3 4 5 6 70
0.5mT
1mT
1mT
Gap h(mm)
Distance x(mm)
6
5
4
3
2
1
0-6 -5 -4 -3 3 4 5 60
2mT
3mT
4mT
4mT
3mT
2mT
Gap h(mm)
Distance x(mm)
0.5mT
Sensing area Sensing area
Conditions under which magnetic property is measured The distribution of the magnetic
force of “Magbase”was measured under the conditions described. The figures are not guaranteed values but average values.
AG004
AG004H
AG011 AG011-K(Powerful type)
AG002
AG002H
AG003
AG003H
Magnetic property
9
Figure-1. In case of polarized magnetic switches
Figure-2. In case of non-polar magnetic switches
N S
Stroke
S-pole sensing area
N-pole sensing area
Operating curve
Gap
(ON length)
Circumference face of a magnet
N-pole sensor (head-side)
Gap between magnet and sensor
Ring Magnet
S-pole sensor (rod-side)
Operating curve
Ring magnet
N S
N S
Head-side sensor
Gap between magnet and sensor
Rod-side sensor
Stroke
(Sensing area)
Brown
BlackRed
Blue
Indicator
DC5~24V
Sensing circuit
Load
Switches for Air Cylinders detect the movement of magnetic field which is emitted from a magnet mounted on air cylinder piston. These switches are capable of stable and high precision operations because of having a operating point on steep area of the operating curve. N-pole and S-pole sensors shall be used in combination.
Conventional switches use non-polar “magnetoresistance element” or “magnetic
coils”. In the case of non-polar sensor, the sensor head should face the magnetic
field lines to detect the intensity of the magnetism ; the operating curve becomes the
pattern shown in the figure-2. As the curve takes a chevron pattern with its midpoint
as the peak, the operating points at along the ascent and descent slopes are
distant. Furthermore since the slopes are shelving, it is difficult for conventional
switches to get a due accuracy or stability.
Switches for Air CylindersHigh precision, Reliable, Contactless
Built-in switch
Response time
Power supply
Output form
Operating temperature range
Detection sensitivity
Degree of protection
Case material
Cable material
Single
5μ sec
DC 5 ~ 24V
NPN Normally open (15mA max.)
-20 ~ +85℃
AH006 3.5 ~ 5mT AH007, 008 3.5 ~ 8.5mT
Equivalent to IP67
GF reinforced PBT(Black as standard)
Heat-resistant vinyl-insulated sensor cable; 1m(standard)
Features
In case of the conventional product
Connection example(circuit diagram)
Specifications
Patent applied for
10
Bracket 3 (dedicated nut included)
Air cylinder
Switch Switch
Air cylinder
Bracket 4 (commercial M3 nut to be used)
Note: For reverse mount, all brackets can be set flipped horizontally and switches can be caracoled back and forth.
Examples of the use of bracket 3 and 4.
Groove for bracket
Sensing pole is indicated
Indicator
Sensing face
φ2.85.5
2.5
5.6
12.5
20
6.1
4.8
5.1
Sensing face
Sensing pole is indicated.R2
205.5
6.5
φ2.8Indicator
Setscrew2.5
2.7
φ4 groove of air cylinder
φ2.8
(Without indicator)
Setscrew
φ4 groove of air cylinder
14.5
φ4
Sensing face(N)
Sensing face(S)
6.5
approx.100 227
N
SIndicator
[Rectangular, indicator built-in type]
Model
AH006-S
AH006-N
Sensing pole
S-pole
N-pole
Note: Both S and N sensing are available with this model. The factory set disposition of S-pole is downside. When setting N-pole downside, please reinsert a setscrew from the reverse side.
[φ4 groove, inversion type]
Model
AH007
AH007-LED
Sensing pole
Two-pole functional
Two-pole functional
[φ4 groove, indicator built-in type]
Model
AH008-S
AH008-N
Sensing pole
S-pole
N-pole
When adopting only one switch for one side (either rod side or head side) of air cylinder, you might not be certain whether to use N or S-pole typed switch. Since magnets of marketed air cylinders usually have N-pole magnetism at rod side (S-pole at head side), please choose a switch with opposite magnetism(refer to figure-1, P9). Before purchase, please check the direction of cylinder’s magnetism, as the polarization of some cylinders is inversed. A reverse connection of +(brown) and OV(blue) of power supply is strictly prohibited as it might cause a damage of the product.
●
●
Precautions
Model Dimensions(mm)
AH006
AH007
AH008
Lineup of Switches for Air Cylinders
11
con tac t l e ss sw i t ch
N
S
N
S
Spring
Sensing face Housing(nonmagnetic material)
S-pole sensing circuit
Ferromagnetic object
Magnetism
N
S
N
S
Ring magnet
With indicator Without indicator
Brown
Black
Blue
DC 5~24V
Brown
Load
Load
Sensing circuit
Sensing circuit
Black
Blue
RedDC 5~24V
Ferrous Proximity SwitchesProximity switches for detecting ferromagnetic materials such as ferrous metals.Not react to such materials as aluminum or nonmagnetic stainless steel.
When a ferromagnetic object such as ferrous metals approaches the sensing face, magnet is pulled toward the object. Then, the sensing circuit detects S-pole and the switch is activated.
Sensors are deactivated because magnet is being pushed by springs and the detection circuit is within the N-pole magnetic field.
When ONWhen OFF
Supply voltage
Output form
Maximum load current(DC24V)
Operating temperature range
Operating humidity range
Degree of protection
Cable length
Operation indicator
DC 5 ~ 24V
NPN Normally open
-20 ~ +85℃
20 ~ 95% RH
Equivalent to IP67
1m(Standard)
Included(AR101, AR002)
Option(AR001, AR011)
Mechanism
Connection examples(circuit diagrams) General specifications
The models with B as trailing character mean Normally closed.15mA(Amplifiable to 80mA with optional cable), refer to P4
12
Model Dimensions(mm)
con tac t l e ss sw i t ch
Indicator
Sensing direction8±2
φ5
4.5
9
2-φ2.6
3749
15 18
4.5
2.5
9
63
2-φ2.3
Mounting bracket (SUS) demountable
6.3 7
124
Sensing face
6.3
4 8.3
Hex 13 nut
M10×0.75
Sensing face
22.82.5
914
■ Mounting bracket for AR002
IndicatorSensing face
M2
6.521
φ2.8
4.5
7
Sensing face downside
2-φ3.5
Sensing face upside
2127
2.5 8T 0.6
SUS, brass screw
AR001AR001(B)
AR011AR011(B)
AR101AR101(B)
AR002AR002(B)
Model
Maximum sensing distance [mm] Sensing axis : horizontal
Response time
Case material
Model
Maximum sensing distance [mm] Sensing axis : horizontal
Response time
Case material
Model
Maximum sensing distance [mm] Sensing axis : horizontal
Response time
Case material
AR 001/AR 001(B)
Iron wire φ0.5 1.0
High speed steel drill φ1 1.5
Iron□10×t 0.3 2.2
Iron□10×t1 1.5msec
Heat resistant ABS
AR 002/AR 002(B)
Iron□30×t10 6.5
Iron□30×t1 4.5
Iron, M5 nut 2.7
Iron□10×t 2 2msec
Grass-fiber reinforced PBT
AR 011/AR 011(B)
Iron wire φ0.5 1.0
High speed steel drill φ1 2.0
Iron□10×t 0.3 2.4
Iron□10×t1 1.8msec
SUS303
AR101/AR101(B)
Iron wire φ0.5 1.0
High speed steel drill φ1 2.0
Iron□10×t0.3 3.0
Iron□10×t1 1.8msec
SUS304 for sensing part Heat resistant ABS for body
Specifications
Model Operation
AR011
AR011-LED ( ) AR011(B)
AR011(B)-LED ( )
N.O.
N.C.
Operation
N.O.
N.C.
Model Operation
AR101
AR101(B)
N.O.
N.C.
Model Operation
AR002
AR002(B)
N.O.
N.C.
Model
AR001
AR001-LED ( ) AR001(B)
AR001(B)-LED ( )
Lineup of Ferrous Proximity Switches
Model
Maximum sensing distance [mm] Sensing axis : horizontal
Response time
Case material
Model
Maximum sensing distance [mm] Sensing axis : horizontal
Response time
Case material
Indicator along the lead wire
Indicator along the lead wire
Indicator along the lead wire
Indicator along the lead wire
13
con tac t l e ss sw i t ch
L
Brown
Load
Sensing circuit
Black
Blue
DC 5~24V
Door SensorsSturdy, Highly-sensitive, Reliable
DC 5 ~ 24V
NPN Normally open (15mA)
5μ sec
Refer to the right table
-20 ~ +85℃
GF reinforced PBT (Black)
Equivalent to IP67
Ferrite magnet embedded
Power supply
Output form
(Cable option)
Response time
Sensing distance
Operating temperature range
Case material
Cable material
Degree of protection
Door“Mag”
ADH02 ADG02 15
12
5 (Iron made door with φ12 hole)
15 (Nonmagnetic door)
ADH02X ADG02X
ADH02 ADG02 Example of door embedding
Door“Mag” Sensor Functional diagramSensing distance ・ L(mm)*
* The actual detecting distance can be longer depending on the surrounding conditions(iron material, etc). The materials of nonmagnetic door include aluminum, SUS304, glass, wood and resin. You have free choice on the way to combine a “Mag” and a sensor; e.g. a“Mag”with lateral magnetic face and upward detecting sensor, the opposite combination, and so forth.
ADH02
ADG02 ADG02X
ADH02X
Commodity Model
Sensor ADH02
Sensor ADH02X
Door“Mag” ADG02
Door“Mag” ADG02X
* Note:a letter of “L” to be suffixed to the number of models with which the cable extends from the left-hand side against the sensing side.
*
New Series
Features
Specifications Sensing distance
Connection example(circuit diagram)
Refer to P4 for N.C. 80mA, indicator, etc.
Heat-resistant vinyl-insulated sensor cable: 1m
● Compact-sized, highly-sensitive door sensors. ● High reliability and long functional life because of lack of physical contact.
● Any fast moving object detectable. ● Even in the case of incorporation into iron-made doors, capable of practical use by having a φ12 hole to let magnetism work.
14
con tac t l e ss sw i t ch
ADH02X (Sensor)
ADG02X (Door“Mag”)
ADH02 (Sensor)
ADG02 (Door“Mag”)
M4 tap model (option)
Tap hole for M4
M4 screw
Clamping torque:0.5N・m
Magnetism, lateral side(S-pole)
Magnetism, upward (S-pole)
14
R5
6
ADG02
ADH02
ADG02X
ADH02X
1414
34
28
2-φ3.6
(For M3 screw)
14
The side a cable extends (standard)φ2.8
34
28
3.8
2-φ3.6
(For M3 screw)
14
14
6
R5
Upward sensing
3
Sensing directionL mode(option) (ADH02XL)
2-φ3.6 (For M3 screw)
14
34
28 3.2
The side a cable extends (standard)φ2.8
Door Sensors
Door“Mag”
Mounting Examples of Door Sensors
Note: 1. The clamping torque for M3 screw is 0.8N・m. 2. The mounting hole can be changed to M4 screw hole at the user’s option. (A change to M4 screw can prevent the unit from being demounted easily as the screw head comes under the surface level.) The clamping torque for M4 screw is 0.5N・m. A nut can be used to tighten up the screw.
15
con tac t l e ss sw i t ch
S N
SpringMagnet
Magnetic sensing circuitHousing(nonmagnetic material)
Contact Probe Slide guide
Brown
Black
Blue
DC 5~24V
Load
Brown
Black
Blue
DC 5~24V
Relay
Output 2
Output 1
Brown
Orange
Black
Blue
DC 5~24V
Sensing circuit
Sensing circuit
Sensing circuit
Load
Load
Sensing circuit
Contactless Touch Switches
An external input pushing or pulling the probe moves the magnet back or forth, respectively. Sensing the magnet’s movements, the magnetic sensing circuit induces ON / OFF action and functions as a touch switch.
Supply voltage
Output form
(Cable Option)
Speed of IC response
Operating temperature range
Operating humidity range
Indicator along the cable
MechanismDC 5 ~ 24V
NPN N.O. or N.C.
Refer to P4
5μ sec
-20 ~ +85℃
20 ~ 95% RH
Approx.100mm from the switch head
Without LED:15mA max. With LED:12mA max.
Single Double
Connection with sequencer, etc.
Connection with a relay, etc.
4 Patents applied for
● Long lasting, stable operation even under frequent use because of lack of physical contact. ● Capable of very high precision in repeatability of operating point. ● The configuration separating moving parts from sensing part enables environment resistance. ● Can be customized to a model of limited operational force.
Features
General specifications
Connection examples (circuit diagrams)
N.O. as standard without notice( )
16
con tac t l e ss sw i t ch
Sensing position
1
Stopper
1
Stopper
1
Stopper
Touch Sensor, Sensor for bottom dead center
Example of mounting in stop wall
Example of using stop nut
Example of using stop block
34
Hot-melt protection
Cable connectorIt is recommendable to use a cable connector when the cable path is long, or a separation of cable path is necessitated. We employ Sumitomo 3M’s sensor connector, namely Mini-Clamp Connector, and have the loose wires coated with hot-melt resin. The connector has high reliability and prevents connect failure when jointing/releasing.
Option
Although our products are designed to ensure safety and address risks, in case that a switch malfunction or failure is expected to lead to
serious risks to life or property, please be advised to expand further safety gear such as the incorporation of dual circuit.
(1)Prevention of reverse connection…Please observe the circuit diagrams so as to ensure correct connections. Reverse connection of
power supply is strictly prohibited.
(2)Relay drive…When driving a relay, please connect a freewheel diode in parallel.
(1)Clamping torque…Please observe the value of torque designated for each switch.
(2)Cable handling…Do not subject the connecting part between cable and switch-head to tension(tensile strength as 20N at max., the
bending radius as 7mm at least).
● Precautions for safety use
● Correct wiring
● Mounting the switch
Precautions
Cable connector(joint state)
Examples for Application of Screw-type Switches
● Connector jointed
● Connector released
17
con tac t l e ss sw i t ch
4.8
7.4
4
47 ± 0.3 (O.P.)
2 - φ2.2 × 3.2
13.8 55.3 φ2.8
(1.4)
OUT(Black) Ov(Blue) +v(Brown)
1.8 13.1
44 ± 0.2 (O.P.)
φ1.4
4.8
3.2
φ2.8
2 - φ2.2 × 3.2
5.3
7.2
2.6
Rubber seal
OUT(Black) Ov(Blue) +v(Brown)
72.80.3
2.6
φ1.4
φ4
0.4
1.27
1.27
6.4
0.77.710
9.5 ± 0.2
10
(O.P.)
+v Ov OUT
OUT O +
Contactless Touch Switch
Micro Switch
Micro Switch
● Operating temperature range for rubber-sealed models:10℃~60℃
●Operating temperature range for rubber-sealed models:10℃~60℃
Dimensions(mm)
Dimensions(mm)
■ Button type
■ Lever type
±0.02mm
Heat resistant ABS
Nitrile rubber
Repeatable precision
Case material
Rubber seal material
±0.02mm
Heat resistant ABS
Nitrile rubber
1m
Repeatable precision
Case material
Rubber seal material
Cable length
Not included
Included
Not included
Included
0.6
0.8
0.3
0.4
0.15
0.1
N
Button type
Lever type
Standard modeRubber seal Low operation force
Rubber sealOperation force
H : Standard J : Low operation force
U : with seal Blank : without seal
Operation
MS1 A - H U EOperating part
E : Lever type Blank : Button type
MR1 A- H URubber sealOperation force
H : Standard J : Low operation force
U : with seal Blank : without seal
Model
A : N.O. B : N.C.
A : N.O. B : N.C.
Operation
Patented
*Note:Low operation force type is not available with rubber-sealed models.
Specifications
Model
Maximum operation force
*
*Note:Low operation force type is not available with rubber-sealed models.
*
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
Specifications
18
con tac t l e ss sw i t ch
7
(8)
φ1.1
φ1.61
φ4
R1.5 6 2
NT 19Cable φ2.8×1m
M6×0.5Clamping torque : 2N・m max.
3~4-wire of φ3 max.
Cable length(1m as standard)
φ1.5
(φ1.0)
φ0.8
(φ0.4)
Hole φ3.1 Mounting plate 1~1.5t
83
Toothed washerM3 Nut
0.5±0.15 LPT
(Length of operating point)
22.5
8
5 (Stroke)
Contactless Touch Switch
Needle Switch
Dimensions(mm)
Dimensions(mm)
1.4mm
0.3~0.6mm
0.1mm max.
0.3N
0.002mm
0.01 max.
SUS303
IP65
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD]
Operation force
Sensitivity of operating point
Stability of operating point(error margin)
Case, nut, shaft
Degree of protection
0.06mm
5mm
0.25N
SUS
Repeatable precision
Stroke
Operation force
Needle material
Needle Switch
Note: Do not apply force of more than 15N.
A : N.O. B : N.C.
N3 08 - L 100 - DLength of operating point(mm) Built-in switch
20, 30, 40, 50, 75, 100, 150 Other options, 1000 max.
S : Single D : Double (differential distance 1.5±0.3)
Needle’s diameter
08 : φ0.8 04 : φ0.4
N6 A - 60 - LEDOperation Cable indicatorNT(mm)
40, 60, 80, 100 Blank : without indicator LED : with indicator
Specifications
Model
Model
Specifications
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
19
con tac t l e ss sw i t ch
24
204
φ2
2.5
Rubber seal
R2.5 M8×0.75
Cableφ2.8×1m
10Rubber Seal
Structure
13
(15)
R4
φ2.2
Rubber seal 2.5
9.5 17.5
27
M10×0.75
Cable, 1M as standard 3 to 4-wire of φ3 max.
Contactless Touch Switch
M10 Touch Switch
*The standard double is N.O.+N.C. combination as per the left figure.
STM10-0.4A+1.2B(Notation of optional model)
〈Standard double〉
Operating point 2
Output under N.O. Output under N.C.
Operating point 1
* When specifying the positioning of operating point 2, the max. pitch shall be 1.6 with an error margin of ±0.15.
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD]
Operation force *Note:Do not apply force of more than 30N.
Sensitivity of operating point
Stability of operating point( )
Clamping torque
Degree of protection
Material of Case, nut, axis
1.5 mm
0.4~0.7 mm
0.1mm max.
0.3N
0.002 mm
0.01mm
5N・m max.
Equivalent to IP67
SUS303
Stroke[FT]
Idle margin to operation[PT] S:Single switch D:Double point 1
Double point 2
Hysteresis[MD]
Operation force *Note:Do not apply force of more than 25N.
Sensitivity of operating point
Stability of operating point( )
Clamping torque
Degree of protection
Material of Case, nut, axis
3 mm max.
0.3 ± 0.15mm 0.3 ± 0.15mm 1.0 ± 0.15mm
0.1mm max.
2N
0.002 mm
0.01mm max.
15N・m
Equivalent to IP67
SUS303
M8 Touch Switch
STM8- B- LEDOperation Cable indicator
Blank : without indicator LED : with indicator
STM10- S BBuilt-in switch
S:Single D:Double
Operation
Single Blank : N.O. B : N.C. Double Blank : N.O.+N.C.
Blank : N.O. B : N.C.
N.O.+N.O. , N.C.+N.C. are also available
Strong Case・Outdoor-safe type
Dimensions(mm)
Dimensions(mm)
Specifications
Model
Specifications
Model
Addition to the series
error margin
error margin
Stroke 3
1±0.15
0.3±0.15(N.O.)
(N.C.)
Operating point 1
Operating point 2
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
20
con tac t l e ss sw i t ch
Cableφ2.8×1m
7
(8)
21
18.52.5
φ1.4
2M6×0.5
Rubber seal
R1
35
305
φ2.7
2.5
Rubber seal
R3M8×0.75
Cableφ2.8×1m
10
M6 Touch Switch
Contactless Touch Switch
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD]
Operation force *Note:Do not apply force of more than 30N.
Sensitivity of operating point
Stability of operating point( )
Clamping torque
Degree of protection
Material of Case, nut, axis
3 mm
0.4 ~ 0.7 mm
0.1mm max.
0.8N
0.002 mm
0.02 mm
5N・m max.
Equivalent to IP65
SUS303
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD]
Operation force *Note:Do not apply force of more than 30N.
Sensitivity of operating point
Stability of operating point( )
Degree of protection
Clamping torque
Material of Case, nut, axis
1.2 mm
0.4 ~ 0.7mm
0.1mm max.
0.3N
0.002 mm
0.01mm
Equivalent to IP67
2N・m max.
SUS303
M8 Long Touch Switch
STM6- B- LEDOperation
Blank : N.O. B : N.C.
Cable indicator
Blank : without indicator LED : with indicator
Blank : N.O. B : N.C.
STM8L- - LEDOperation Cable indicator
Blank : without indicator LED : with indicator
Dimensions(mm)
Dimensions(mm)
Specifications
Model
Specifications
Model
error margin
error margin
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
21
2
3
4
Operating point 1
0.5 a
b
c
0 ≦ a < b < c ≦ (Stroke -0.5) The accuracy of a,b,c positioning is ±0.1mm.
2
3
4
Operating point 1
0.5 a
b
c
0 ≦ a < b < c ≦ (Stroke -0.5) The positioning adjustable by users.
HEX17
(19.6)
54 5.5
Ball contact type
M14×0.5Ball R1.5
Rubber boot
6(Stroke)
Boot protector
32.5
5532.5
3
φ6
φ6.5
Plane contact type
φ13
3 to 6-wire cable φ4(max.)
59
M14×0.5
R1.5 Rubber boot φ8
(Stroke) 6
4.536.5
3
φ6
19.6
17 Adjustment screw
(a dedicated screwdriver included)
38
1
Indicator(NO.1~4)
3 to 6-wire cable φ4(max.)
Contactless Touch Switch
PM4 type Touch Sensor
PM5 type Touch Sensor
6mm
0.5~1.5N
4μm
0.01mm
0.08mm
5μ sec max.
1~4
Stainless steel(SUS303)
20N・m
Nitrile rubber
1m
Stroke
Operation force
Operation sensitivity
Repeatable precision
Hysteresis
Response speed
Operating point
Material of case and nut
Clamping torque
Rubber boot material
Cable length
Precautions● The touch angle of the stroke axis against sensing object should be 5° or less. ● Do not apply rolling force to the contact part(0.1N・m max.)
● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the sensor.
Precautions● The touch angle of the stroke axis against sensing object should be 5° or less. ● Do not apply rolling force to the contact part(0.1N・m max.) ● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the sensor. ● As the adjustment screw part at the back end of the case has fine and precision mechanics, due attention and careful handling are required to prevent functional impairments.
*The size of indicator varies in proportion to the number of switches.
6 mm
0.5~1.5 N
4μm
0.01mm
0.08mm
5μ sec max.
1~4(Setting range:0~4mm each)
Stainless steel(SUS303)
20N・m
φ3 carbide ball
1m
Stroke
Operation force
Operation sensitivity
Repeatable precision
Hysteresis
Response speed
Indicator
The number of switches
Material of case and nut
Clamping torque
Tip shape
Cable length
PM4- 6 S -M4 - 0.8 - 2.5 - 4.0Stroke(mm) Shape of the contact part
S : SUS ball C : Carbide ball P : Carbide plane
6
The number of switches
Location of operating points(mm)
1~4
a b c
PM5- 6 C - 3Carbide tipφ3 ball
Dimensions(mm)
Dimensions(mm)
Model
Specifications
Specifications
Model
Stroke(mm)
6
The number of switches
1~4
LED display unit along the cable, approx. 120mm distant from the sensor head
22
2
3
4
Operating point 1
0.5 a
b
c
0 ≦ a < b < c ≦ (Stroke -0.5) The positioning adjustable by users.
59
M14×0.5
(Stroke)
(Chamfer)
6
36.519 2
3
φ6
M2.5×5
19.6
17
5 Adjustment screw
(a dedicated screwdriver included)
38
1
Indicator(NO.1~4)
*The size of indicator varies in proportion to the number of switches.
Probes to replace (please purchase commercial products)
Precautions● When installing a probe, hold the tip with 5mm spanner, and screw the probe into the case firmly.● Do not apply a torque of more than 1N・m to the connection between the probe axis and the case.
PM6- 6 - 2
Contactless Touch Switch
PM6 type Touch SensorProbe-changeable type
Dimensions(mm)
Specifications
Model
Stroke(mm)
6
The number of switches
1~4
6 mm
0.5~1.5 N
4μm
0.01mm
0.08mm
5μ sec max.
1~4(Setting range:0~4mm each)
Stainless steel(SUS303)
20N・m
M2.5×0.45 Female screw
1m
Stroke
Operation force
Operation sensitivity
Repeatable precision
Hysteresis
Response speed
Indicator
The number of switches
Material of case and nut
Clamping torque
Tip shape
Cable length
LED display unit along the cable, approx. 120mm distant from the sensor head
Addition to the series
23
con tac t l e ss sw i t ch
Cable φ2.8×1m
22.5
4.5 7.5 7.5
5.5 3
11
Cable φ2.8×1m
2-φ3.5
φ7φ2.2
310
0
12.4
15.5
15+0-0.3
φ2, Tip R2.5
26.7
12 446.7
10
(Operating point)
+0.3-0
03
8
12
8
φ2.6
(for M2.5)
φ2.6×3.2
Seal section
Flat Switch
Slim Switch
Contactless Touch Switch
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD]
Operation force *Note:Do not apply force of more than 15N.
Sensitivity of operating point
Stability of operating point(error margin)
Degree of protection
Case material
Axis material
3mm
0.4~0.7mm
0.1mm max.
0.5N
0.002mm
0.01mm
Equivalent to IP65
Die casting zinc alloy
SUS303
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD]
Operation force *Note:Do not apply force of more than 15N.
Sensitivity of operating point
Stability of operating point(error margin)
Degree of protection
Case material
Axis material
3mm
0.3~0.6mm
0.1mm max.
0.7N max.
0.002mm
0.01 max.
Equivalent to IP67
Die casting zinc alloy
SUS303
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the switch.
Precautions● Because of the possible damage, do not push the button over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the switch.
STF15- - LED
STS8- - LED
Dimensions(mm)
Dimensions(mm)
Model
Specifications
Model
Specifications
Operation
Blank : N.O. B : N.C.
Blank : N.O. B : N.C.
Cable indicator
Blank : without indicator LED : with indicator
Operation Cable indicator
Blank : without indicator LED : with indicator
24
con tac t l e ss sw i t ch
Mounting pitch when disposing plural units side-by-side
Cable protector (option)
Operation indicator (option)
16 16 8
9
16 1
19.2 ±
0.3
(FP)
18 ±
0.2
(OP)
292-M4 mounting hole
4125.4 7
1521.5
(OF)
Contactless Touch Switch
Limit Switch
Power supply
Output form
Response speed
Degree of protection
Ambient temperature range
Case material
Material of chevron shaped lever
Material of flexural plate
Material of corrugated seal
Material of cable seal
Material of cable protector
1.2N max.
1.4mm max.
0.5mm max.
18± 0.2 mm
3.3mm max.
Precautions● Because of the possible damage, do not push the lever over the stroke range.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the switch.
Bare cable : blank
With cable protector : G
HS1 P - GOperation indicator
Without : blank With : P
Operation force
Idle margin to operation
Hysteresis
Operating position
Max. stroke
[OF]
[P T]
[MD]
[OP]
[ F T]
Dimensions(mm)
Model
SpecificationsDC 5 ~ 24V
NPN Normally open 15mA max.
5μ sec max.
Equivalent to IP67
0 ~100℃
Polyimide resin plate
Polyimide plate 0.75μm
Nitrile rubber
SUS304
Aluminum alloy Black alumite treatment
SUS304 Nitriding treatment(Hmv1300)
Features ● Contactless circuit
Superior reliability and long functional life compared to mechanical contact switches, durable more than 20 million operations.
● Shielded structure Immune to hostile environments, available under such conditions as pouring water / oil.
● Stable operation Because such parts susceptible to common troubles as hinges and sliding parts, are not exposed, stable operation can be assured.
● High sensibility The accuracy of the repeatability of operating point is ±0.02mm.
25
con tac t l e ss sw i t ch
4
9.6
φ10
0.9
R2
120°V shaped groove, Width 0.9 (for fixing set screw)
Lead φ0.9×3×0.3m
φ1.6
Section of seal at axis part
Rubber seal (EPDM)
Protector
19
5.50.4 ± 0.1 (OP)
18
5
φ4 ball
M14 - P1.5
(22)
φ30
18.5 ±
0.1
(OP)
18
2 - φ3.5, φ6 Depth of spot facing 4.5
21
Cable protector (option)
Stopper Switch
Stopper Switch
Mini Stopper Switch
Contactless Touch Switch
5μ sec max.
SUS304
Nitrile rubber
IP44
10kN
Response speed
Case material
Material of cable seal
Degree of protection
Static withstand load
5μ sec max.
SUS304
Nitrile rubber
SUS304
Equivalent to IP67
100kN
Response speed
Case material
Material of cable seal
Material of cable protector
Degree of protection
Static withstand load
Stroke[FT]
Sensing point(from the bottom)
Hysteresis[MD]
Operation force
Withstand load of stopper (Vicinity of the center with φ3 rod)
Withstand load of stopper (Vicinity of the center with φ10 rod)
Sensitivity of operating point
Stability of operating point( ) Degree of protection
Material of case and axis
*
0.7~1mm
10±0.2mm
0.1 max.
0.5N
80N (Static load)
1,000N (Static load)
0.003mm
0.02mm
Equivalent to IP67
SUS303
Precautions● Do not push the actuator over the stopper level due to risk
of damage.● Do not prod the seal part of STB30 with edged stuff due to
risk of damage.● Extremely strong magnetic field(more than 1,000 Gauss)
might cause malfunction of the switch.
Precautions● Do not push the actuator over the stopper level due to risk
of damage.● Extremely strong magnetic field(more than 1,000 Gauss)
might cause malfunction of the switch.
Precautions● Do not push the actuator over the stopper level due to risk
of damage.● Extremely strong magnetic field(more than 1,000 Gauss)
might cause malfunction of the switch. *Do not push the actuator face to the extent that the tip sinks under the level of protector’s surface.
STR10 - LED
STM14
STB30 - GDimensions(mm)
Dimensions(mm)
Model
Specifications
Model
Specifications
Operation
Blank : N.O. B : N.C.
Blank : N.O. B : N.C.
Blank : N.O. B : N.C.
Bare cable : blank
With cable protector : G
Model
Specifications
Operation
Operation Cable indicator
Blank : without indicator LED : with indicator
Dimensions(mm)
error margin
26
con tac t l e ss sw i t ch
φ3.5 ball
Threaded cap Chamfer 8
SUS303
9.311.712.9
φ12
φ9.2
When used as a ball plunger switch(STMB10□-H)
When used as a touch switch
φ2
0.1~0.2Actuator operates
also with a slide contact
Cable φ2.8×1m
13
(15)
φ6.5
φ3.5 ball2.5
1.2 17.52.520
Cable φ2.8×1m
M10×0.75Clamping torque:13N・m max.
( )
Cable indicator
LED : with indicator Blank : without indicator
Contactless Touch Switch
M10 Ball Plunger Switch
12 Ball Plunger Switch
1mm
0.3~0.6mm
0.1mm max.
0.002mm
0.01 max.
-20~+85℃
SUS
IP65
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD] Sensitivity of operating point
Stability of operating point(error margin)
Operating temperature range
Material of case, nut and ball
Degree of protection
1mm
0.3~0.6mm
0.1mm max.
0.002mm
0.01mm max.
-20~+85℃
SUS
IP65
Stroke[FT]
Idle margin to operation[PT]
Hysteresis[MD] Sensitivity of operating point
Stability of operating point(error margin)
Operating temperature range
Material of case and ball
Degree of protectionNote: When the movement of the ball lacks smoothness, take off the cap, clean the ball, moving-axis and spring, and reassemble the parts.
Operation Operation force(max.)
H : 5N J : 0.5N
STMB10 A - H - LED
STFB12 A - H - LED
Specifications
Model
Specifications
Model
Cable indicator
LED : with indicator Blank : without indicator
Operation
A : N.O. B : N.C.
A : N.O. B : N.C.
Operation force(max.)
H : 7N J : 0.5N
Dimensions(mm)
Dimensions(mm)
Examples of use
Addition to the series
Addition to the series
27
con tac t l e ss sw i t ch
Cable φ2.8×1m
328.5 40(15)
φ2.4Operation force
φ4
5(2.5)
+0
-0.03
φ14
Indicator along the cable
38
419
20
3
1
4 2
2-φ3.5
55
φ20
30.5
7.54.50
25
2026
Cable φ4×1m
Valve in ( ) for rod S
Operation force(max.)
H : 3N J : 0.5N
5mm, all-around(2.5mm for rod S)
1.5~2.5mm
Error margin of repeatability 0.1mm max.
H:2N, J:0.8N (Allowable operation force H:8N, J:5N) (Double valve for rod S)
Electrical responsiveness 5μ sec
Equivalent to IP67
SUS303
SUS303(Option:Jade ball)
Fix the φ14 part of the body with clamping fastener, etc.(set-direction; free).
Heat resistant vinyl chloride, sensor cable, 1m(standard)
Stroke[FT]
Operating point(OP)
Accuracy of operating point
Operation force(tip)
Response speed
Degree of protection
Case material
Material of axis and ball
Case mount
Cable
Probe Switch
Four-way Probe Switch
Contactless Touch Switch
four-way at 90 degree angle
All-around 3±0.5mm
1.5±0.5mm
Error margin of repeatability 0.015mm max.
H lever:3N, J lever:0.5N (Allowable operation force 5N)
Electrical responsiveness 5μ sec
4×NPN Normally open(15mA max.)
Equivalent to IP67
Zinc die-cast
Black:Phenol
Heat resistant vinyl chloride, 6-wire sensor cable, 1m(standard)
Operational option
Stroke[FT]
Operating point(OP)
Accuracy of operating point
Operation force (globe side)
Response speed
Output form
Degree of protection
Case material
Spherical grip
Cable
Precautions● Do not push the probe over the stroke due to risk of damage.● Do not roll the probe due to risk of damage.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the switch.
Rod length
L : 40 S : 15
AX1 L H - LED
AX4 H - LED
Specifications
Model
Specifications
Model
Dimensions(mm)
Dimensions(mm)
Cable indicator
LED : with indicator Blank : without indicator
Patents applied for
Return spring
H : Hard J : Soft
Cable indicator
LED : with indicator Blank : without indicator
Connection example (circuit diagram)
Precautions● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction
of the switch.
Brown
BlackOutput 1
DC
5~24V
Orange
Blue
Purple
Pink
Sensing circuit 1
Output 2
Sensing circuit 2
Output 3
Sensing circuit 3
Output 4
Sensing circuit 4
Load
28
con tac t l e ss sw i t ch
Brown
Black
Orange
Blue
DC+24V±10%
Output of tip senseN.O.
N.C.
Limit output
0V
Sensing circuit 1Sensing circuit 2
Load
■ UTS -10 - 2T
Load
DC+24V±10%
PT≒0.5mm >3.5mm
Stroke
Output of tip sense
N.O.
N.C.
Limit output
0V
-V
-V
+V
+V
ON
OFF
ON
OFF
Sensing circuit 1Sensing circuit 2
Load
Output of tip sense
Limit outputOutput position to be consulted
■ UTS -10 - 2F
Load
Brown
Black
Pink
Orange
Purple
Blue
14.6
24
42 28
18
324 - M6 Thread depth 6.5
10
87.5
Stroke
φ13 Carbide contact
54
55.5
M5 Air blow line entry
LED
Cable slot
Contactless Touch Switch
High-precision Tool Sensor
● Ultrahigh repeatable precisionBenefits of unique magnetic circuit and application of Hall IC realized the accuracy of 0.2μm(3σ)in repeatability of operating position. Perfect for evolutionary NC processing machines.
● Trouble free with non-contact structureContactless circuit structure assures operations free from any troubles caused by contact degradation. The installation is easy because the output can be relayed directly into e.g., sequencers without amplification along the path.
● Smooth and reliableBall slide system ensures smooth movement. Capable of low-profile mode, suited to small drills, etc, as well.
DC 24V ±10%
10 mm
0.2μm(3σ, 20℃)
Vertical and horizontal directions
1.8 N(Referential value)
0~+50℃(with no condensation)
Model
Supply voltage
Stroke
Repeatable precision
Application direction
Measuring force
Output form
Consumption current
Operating temperature range
Output capacity(DC24V)
Operational time lag
Precautions● Do not push the actuator over the stroke due to risk of damage.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the sensor.
Open collector with a pull-up
20mA max.
15 mA
5μ sec max.
12 mA
8μ sec max.
50mA max.
Open collector floating
UTS -10 - 2T UTS -10 - 2F
Specifications
Dimensions(mm)
Features
Connection examples(circuit diagrams)
29
Red
Brown
Black
Blue
DC 5~24V
Sensing circuit
Load
φ3.5
8.5
4.2
3.2
10
17.4LED
24.5
32 ±
0.1
11
0.4 ± 0.1
PT
OP
φ3.5
44
12
20 24 29
Ruby contact
M3 Mounting pitch
● Unprecedented ultra-low operation powerWith the measuring force as only 0.01N(1g-f), capable of measuring ultra-fine drills and probes without inclination.
● Repeatability of micron accuracyThe repeatable precision marks 2μm. Suitable also for diamond core tools because ruby is used for the actuator part as standard component.
● Trouble free with non-contact structureContactless circuit structure assures operations free from any troubles caused by contact degradation. The installation is easy because the output can be relayed directly into e.g., sequencers without amplification alog the path.
Features
Tool Sensor for Extra-Fine DrillsContactless Touch Switch
BTS-2-1T
DC 5~24V
2mm
2μm
Vertical
0.01N(1g・f)
NPN Open collector output×1
10mA max.
0~+50℃(with no condensation)
Model
Power supply
Stroke
Repeatable precision
Application direction
Measuring force
Output form
Consumption current
Operating temperature range
Precautions● Do not push the actuator over the stroke due to risk of damage.● Do not push the actuator to other directions than the stroke due to risk of damage.● Extremely strong magnetic field(more than 1,000 Gauss)might cause malfunction of the sensor.
Dimensions(mm)
Specifications Connection example(circuit diagram)
Printed using Soybean oil based ink. Printed on 100% recycled paper.
Techno Eight Kodaira Building 5-16-8, Ogawahigashi-cho, Kodaira-shi, 187-0031 Tokyo, Japan Tel. : 81-42-341-8551 Fax. : 81-42-341-8826 http://www.asadenshi.co.jp
*In the interest of improvements, the contents of this catalogue are subject to change without notice.*The catalogue prices do not include consumption tax.
2008.10
ASA Electronics Industry Co., Ltd.
top related