autopump catalog...long ap2-bottom inlet short ap2-bottom inlet 2” top inlet ap pumps long ap2-top...
Post on 02-Nov-2020
7 Views
Preview:
TRANSCRIPT
AutoPump ® CatalogThe Original Automatic Air-Powered Pumps
Sites Around the World
Complete Systems
Featuring the AP andAP4+ Series
AAuuttooPPuummpp®®
AutoPump Automatic Air-Powered Pumps
Automatic air-powered pumps o�er exceptional capabilities in the severe pumping conditions found at manyland�ll and remediation sites. QED’s patented AutoPump originated the automatic air-powered pump conceptin 1986 and have lead the industry ever since. AutoPumps were designed speci�cally to handle di�cultconditions reliably and safely, including hydrocarbons, land�ll lechates and condensates, solvents, suspendedsolids, silts, corrosives, and high viscosities, along with high temperatures and frequent starts and stops.Air-powered AutoPumps are proven worldwide at thousands of sites, which is why AutoPumps are the No. 1choice of professionals based on reliability, durability, performance range and technical support.
Unlike electric pumps, air-powered AutoPumps use no high-speed motors, bearings or impellers, soAutoPumps don’t heat up, sieze up or get ground up. Liquid shearing is typical of electric pumps, creatingoil-water emulsions that reduce the performance of downstream treatment equipment. AutoPumps cause farless liquid shearing than electric submersible pumps so downstream treatment systems can perform better.Air-powered also means eliminating the dangers and costs of electricity at and in the well. Finally,AutoPumps actually have a built-in control system - they pump when there is liquid present and shut downwhen the level is drawn down, without the need for any sensors in the well or controls at the surface.
Application Excellence
Experience and ExpertiseThe AutoPump specialists at QED have unsurpassed experience in both typical and special applications,providing the quality and care that makes a di�erence. Call us at 1-800-624-2026 for prompt, professionalassistance, or visit our web site at www.qedenv.com to access product and application information.
The superiority of the AutoPump design is based on four key strengths:high clearance �uid pathwaysusing air as the motive forcematerials of construction matched to site conditionsa simple yet rugged operating mechanism
Remediation applications and land�ll �uids pumping are very challenging. QED is dedicated to providing acomprehensive approach to meeting the speci�c needs of each site and well, taking into account manyfactors beyond just �ow rate and depth, such as:
Preferred inlet position- top or bottomPump length to match water column and meet drawdown requirementsA broad range of materials of construction to match �uid properties and temperatureJacketed tubing sets, bundled hose and quick-connect options to ease installation and serviceA wide variety of standard and custom wellhead completions to �t site needs
AutoPump ®
Table of Contents
2
3
4
62
63
64
65
66
67
Inside Back Cover
5
6-9
10-13
14-17
18-21
22-25
26-29
30-33
34-37
38-41
42-45
46-49
50-53
54-57
58-61
Long AP4 + Bottom Inlet Pump
Short AP4 + Bottom Inlet Pump
Low-Drawdown AP4 + Bottom Inlet Pump
Long AP4 + Top Inlet Pump
Short AP4 + Top Inlet Pump
Low-Drawdown AP4 + Top Inlet Pump
How AutoPumps Work
Long AP3 Bottom Inlet Pump
Short AP3 Bottom Inlet Pump
Why AutoPumps Are Better
Guide to AutoPumps Selection
Complete Systems
Long AP3 Top Inlet Pump
Short AP3 Top Inlet Pump
Long AP2 Bottom Inlet Pump
Short AP2 Bottom Inlet Pump
Long AP2 Top Inlet Pump
Short AP2 Top Inlet Pump
Tubing and Hose
Well Caps
Flow Counters
Air Supply
Tank-Full Shuto�
Application Data Sheet
Warranty
AutoPump ®
How AutoPumps Work
Fill Cycle Discharge Cycle
The �uid pushes the inlet check valveopen and �uid enters the pump.
With the air inlet open, air pressurebuilds up within the pump body. Thiscauses the �uid inlet check valve toclose and forces the �uid to bedisplaced up and out of the �uid outlet.
As the �uid level falls, the �oat movesdownward to the bottom of its stroke.
In this lower position, the �oat triggersthe lever assembly to close the airsupply and open the air exhaust valve.And a new cycle begins.
Note: This illustration is for a bottom �lling format. Atop loader is also available with both the inlet anddischarge at the top of the pump.
AutoPump Reliability
The AutoPump operating cycle diagrams and explanation above tell just part of the story of AutoPump
technology. Engineering an automatic pump to function in clear water is just the start. The real secrets
of AutoPump durability and reliability are based on over 18 years of site experience in di�cult pumping
applications. AutoPumps are designed to resist chemical attack, abrasive wear, mechanical wear,
solids deposits, viscous �uids and elevated temperatures. The entire air valve control mechanism has
been re�ned in many subtle ways to survive these severe pumping conditions, using special materials,
tolerances, and safety factors to provide years of trouble-free cycling. AutoPumps are the �rst of their
kind, �rst in design experience, and �rst in reliability and durability.
2
As the �uid level rises, air is expelled
In this upper position, the �oattriggers a lever assembly, whichcloses the air exhaust valve and
opens the air inlet allowing air toenter and pressurize the pump.
through the exhaust air valveand the internal �oat rises to
the top of its stroke.
AP
4+
AutoPum
p
3
AutoPump®
1.800.624.2026 F 1.734.995.1170 info@qedenv.com www.qedenv.com
Why AutoPumps Are Better
2355 Bishop Circle West Dexter, MI 48130 USA
Superior float.
QED-developed unique “Easy Fittings”
For quick disconnect/reconnect without the need to shorten pump tubing
or remove/replace tubing clamps.
Superior body. Light weight, won’t corrode, won’t dent.
Same standard 5-year warranty. No other pneumatic pump manufacturer
even comes close.
Maximum flow rate over 14 gpm.
Easy pump disassembly. Removing four bolts allows removal
of the pump casing.
Easy O-ring fit due to precision tolerance casing I.D.
Inlet check plug design durability has been proven at thousands of sites in over 40 countries.
Easily removable float retainer.
Superior materials choice. Most of the AutoPump’s internal components are available in a variety of materials to fit site specific conditions.
QED originated the concept of jacketed tubing to make pump installation/removal easier.
The same time-proven, reliable, air valve assembly that has made the AP4 the industry’s preferred choice since 1986.
Air efficiency Saves up to $300/year in energy costs compared to other pneumatic pumps.
AutoPump ®
Guide to AutoPump Selection
AutoPumps Model Pg# Out. Diameter Overall Lengthin/cm in/cm
Max. Flow 1 Max. Depth Act. Levelgpm/lpm ft/m in/cm
53 / 135
2.3 / 8.82 300 / 91.4 35 / 892 / 7.57 300 / 91.4 20 / 51
300 / 91.4 52 / 132300 / 91.4 31 / 78
1 Consult for higher �ow requirements2 High Pressure Option for 4” AP pumps3 Optional radial inlet model provides 11.5” / 29 cm actuation level4 Optional 2.63” (6.68cm) OD available
4
Quick Guide to AutoPump SelectionAn important advantage of an AutoPump system is the wide range of choices to truly match site needs. Belowis a quick guide to the major con�gurations and options o�ered in the AutoPump line, to help you determinewhich models are best for your project. Of course, you can just call us at 1-800-624-2026, or email us atinfo@qedenv.com, for fast, personal service by our application specialists.
As a general guideline, pump model selection is usually based on the following primary application criteria.They are presented in the common sequence of consideration, but special site needs may alter the priority.
Maximum �ow and depth - pump model, depth, submergence and drive pressure determine themaximum �ow rate that can be achieved; see speci�c pump curves for detailed �ow information
Pump Diameter - to �t the well ID; also, larger diameter pumps deliver higher �ow rates, all otherfactors being equal
Inlet Position - top or bottom inlet; a top inlet enhances removal of LNAPLs, while bottom inletsprovide the highest �ow rates and greatest solids-handling capacity for DNAPL, dissolved and land�ll �uids
Actuation Level - minimum height of liquid needed to actuate the pump, also equal to the minimumdrawdown level; low-drawdown models are optimized for maximum drawdown
Materials of construction - many models are available in upgraded materials for special applications,such as extremes of pH, suspended solids, high temperatures and aggressive solvents
InletPosition
3” Bottom Inlet AP PumpsLong AP3-Bottom InletShort AP3-Bottom Inlet
3”Top Inlet AP PumpsLong AP3-Top InletShort AP3-Top Inlet
2” Bottom Inlet AP PumpsLong AP2-Bottom InletShort AP2-Bottom Inlet
2” Top Inlet AP PumpsLong AP2-Top InletShort AP2-Top Inlet
Long AP3B 54Short AP3B 58
BottomBottom
2.63 / 6.682.63 / 6.68
52 / 13242 / 107
Long AP3T 62Short AP3T 66
TopTop
3.4 / 8.64 4
3.4 / 8.64 457 / 14547 / 119
Long AP2B 70Short AP2B 74
BottomBottom
1.75 / 4.451.75 / 4.45
55 / 13933 / 85
Long AP2T 78Short AP2T 82
TopTop
1.75 / 4.451.75 / 4.45
57 / 14435 / 89
1.9 / 7.21.6 / 6.0
31 / 79175 / 53.3 22 / 56
7.3 / 27.6 220 / 676 / 22.7
5.4 / 20 220 / 674.8 / 18.1 175 / 53.3 42 / 107
5
AutoPump®
Complete Systems
Complete AutoPump® systems offer the greatest assurance of a smooth installation, dependable perfor-mance and easy maintenance. Common system components include:
In-well hose and tubing - see page 86
Barbs, quick-connects and other fitting options - see page 87
Wellhead completion caps and flanges - see page 87
Cycle counters - see page 88
Air system filter/regulators - see page 89
Call or visit www.qedenv.com for prompt assistance with all of the above.
Basic Pump Systems
Basic System Bottom Inlet Pump Basic System Top Inlet Pump
Fluid Discharge
Air Supply From Compressor
Water
Barb Fittings
Cycle Counter
AP4 Bottom Inlet
Note:Support Harness andrope omitted for clarity
AutoPump ®
AP4+B Bottom Inlet, Long
14 gpm (60 lpm)*
3.5 in (8.9 cm)
53 in. (135 cm) o�ered to handle even the most severe remediation and
2.
3.
4.
5. Five-year warranty
* Consult for higher �ow requirements
6
Description
The AP4 + Bottom Inlet Long AutoPump provides maximumcapabilities and �ow in a bottom inlet pump for 4” (100 mm)diameter and larger wells. The base model delivers �owrates up to 14 gpm (53 lpm)*, and optional versions are
land�ll pumping applications. The AP4+ Long Bottom InletAutoPump is complemented by the most comprehensiveselection of accessories to provide a complete system tomeet site-speci�c requirements. Call QED for prompt, no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe AP4 + Bottom Inlet Long AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s speci�cally to handle uniquepumping needs at remediation and land�ll sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle di�cultpumping challenges that other pumps can’t, such as hydro-carbons, solvents, suspended solids, corrosives, tempera-ture extremes, viscous �uids and frequent start/stop cycles.Beyond just the pump, AutoPump systems o�er the mostcomplete range of tubing, hose, connectors, wellhead capsand accessories to help your installation go smoothly. Thissuperior pumping heritage, application experience and supportback up every AutoPump you put to work on your project.
Max. Flow
O.D.
Length
Advantages
1. The original automatic air-powered well pump, provenworldwide over 18 years
The highest �ow rates anddeepest pumping capabilities inthe industry
Patented, proven design forsuperior reliability anddurability, even in severeapplications
Handles solids, solvents,hydrocarbons corrosiveconditions, viscous �uids andhigh temperatures beyond thelimits of electric pumps
7
AutoPump®
Bottom Inlet, Long AP4+BPump Dimensions Specifications & Operating Requirements
Long and short AP4+ AutoPumps are warranted for five(5) years: 100% materials and workmanship first three(3) years; 50% materials and workmanship for the fourth(4th) and fifth (5th) years.
Low-Drawdown AutoPumps are warranted for one (1) year.
Application Limits(Base model)AP4+ AutoPumps are designed to handlethe application ranges described below.For applications outside these ranges,consult QED about AP4 upgrades.
Maximum Temperature: 150°F (65°C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
Length Overall, w / Extended ScreenWeight
Max. Flow RatePump Volume / Cycle
Min. Actuation Level
Standard PumpMax. Depth
Air Pressure RangeAir Usage
High Pressure PumpMax. Depth
Air Pressure Range
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material2
Sizes - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrades available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
4" - Long AP4+ Bottom InletBottom3.5 in. (8.9 cm)53 in. (135 cm)56 in. (142 cm)16 lbs. (7.3 kg)14 gpm (53 lpm) - See Flow Rate Chart*0.58 - 0.78 gal (2.2 - 3.0L )35 in. (89 cm)
250 ft. (76 m)5 - 120 psi (0.4 - 8.4 kg/cm2)0.4-1.1 scf / gal. (3.0-8.5 liters of air /fluid liter) - See Air usage chart
425 ft. (130 m)5 - 200 psi (0.4 - 14.1 kg/cm2)
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, UHMWPE3, BrassStainless Steel, Viton, Acetal, PVDF4
Brass or Stainless SteelBarbs or Quick Connects
Nylon1 in. (25 mm) or 1-1/4 in. (32 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) ODNitrile3/4 in. (19 mm) or 1 in. (25 mm) ID3/8 in. (9.5 mm) ID1/2 in. (13 mm) ID
3 UHMWPE - Ultra High Molecular Weight Polyethylene
4 PVDF - Polyvinylidene Fluoride
*Consult for higher flow requirements
Len
gth
wit
h S
tan
dar
d S
cree
n 4
1" (
104
cm)
Act
uat
ion
Lev
el 2
7" (
69 c
m)
Len
gth
wit
h O
pti
on
al E
xten
ded
Scr
een
Att
ach
ed 4
4."
(113
cm
)
Inlet
Air Supply
Exhaust
O.D. 3.5" (89 mm)
Liquid Discharge
AutoPump ®
AP4+B Bottom Inlet, Long
Flow Rates 1
18 68.1 18 68.1
16 60.6 16 60.6
14 53 14 53
12 AIR INLET PRESSURES 45.4 12 AIR INLET PRESSURES 45.4
10 37.9 10 37.9
8 30.3 8 30.3
6 22.7 6 22.7
4 15.1 15.14
2 7.6 2 7.6
0 020 40 60 80 100 120 140 160 180 200 0 406.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61
18 68.1 18 68.1
16 60.6 16 60.6
14 53 14 53
12 AIR INLET PRESSURES 45.4 12 AIR INLET PRESSURES 45.4
10 37.9 10 37.9
8 30.38 30.3
6 22.7 6 22.7
4 15.1 4 15.1
2 7.6 2 7.6
0 0 00 20 40 60 160 180 200
6.1 12.2 30.5 54.9 61
18 68.1 18 68.1
16 60.6 16 60.6
14 53 14 53
12 AIR INLET PRESSURES 45.4 12 AIR INLET PRESSURES 45.4
10 37.9 10 37.9
8 30.3 30.38
6 22.7 6 22.7
4 15.1 4 15.1
7.62 7.6 2
0 00 20 40 160 180 200
0 20 40 60 80 100 120 140 160 180 200 6.1 12.2 30.5 54.9 616.1 12.2 30.5 54.9 61
1FLOW RATES MAY VARY WITH SIT E CONDITIONS. CALL FOR TECH NICAL ASSISTANCE.
8
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD 6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm 2100 PSI
7 Kg/cm 2
40 PSI3 Kg/cm 2
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
70 PSI5 Kg/cm 2
70 PSI5 Kg/cm 2
0FT.Meters
0FT.DEPTH
IN WELL 206.1 12.2
DEPTH IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONSGALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE100 PSI7 Kg/cm 2
100 PSI7 Kg/cm 2
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
70 PSI5 Kg/cm 2
0FT.Meters
DEPTH IN WELL
DEPTH IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm 2
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2
18.3 24.4
70 PSI5 Kg/cm 2
36.6 42.7 48.8
70 PSI5 Kg/cm 2
36.6 42.7 48.8
0FT.Meters
0FT.Meters
DEPTH IN WELL
DEPTH IN WELL
40 PSI3 Kg/cm 2
40 PSI3 Kg/cm 2
40 PSI3 Kg/cm 2
40 PSI3 Kg/cm 2
0
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
70 PSI5 Kg/cm 2
80 100 120 14036.6 42.7 48.818.3 24.4
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
60 80 100 120 14018.3 24.4
60 80 100 120 140 160 180 20018.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
3/4 inch (19 mm)Inside Diameter Discharge Hose
(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose
(Equivalent to 1.25-Inch O.D. Tubing)
0 20 40 60 80 100 120 140 160 180 200 FT.6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
9
AutoPump®
Bottom Inlet, Long AP4+BAir Consumption
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
70 PSI
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
5 Kg/cm 2
DEPTH IN WELL
STANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
STANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
100 PSI7 Kg/cm 2
70 PSI5 Kg/cm 2
40 PSI23 Kg/cm
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
AutoPump ®
AP4+B Bottom Inlet, Short
13 gpm (49 lpm)
3.5 in (8.9 cm)
41 in. (104 cm)
o�er the most complete range of tubing, hose, connectors,
2.
3.
4.
5. Five-year warranty
* Consult for higher �ow requirements
10
Description
The AP4 + Bottom Inlet Short AutoPump provides maximumcapabilities and �ow in a bottom inlet pump for 4” (100 mm)diameter and larger wells with shorter water columns and/orthe need to pump down to lower water levels, compared tofull-length pumps. It is o�ered in optional versions tohandle even the most severe remediation and land�llpumping applications, and delivers �ow rates up to 13 gpm(49 lpm)*. The AP4 + Short Bottom Inlet AutoPump iscomplemented by the most comprehensive selection ofaccessories to provide a complete system to meet site-speci�c requirements. Call QED for prompt, no-obligationassistance on your pumping project needs.
The AutoPump HeritageThe AP4+ Bottom Inlet Short AutoPump is part of thefamous AutoPump family of original automatic air-poweredpumps, developed in the mid 1980s speci�cally to handleunique pumping needs at remediation and land�ll sites.Over the years they’ve proven their durability at thousandsof sites worldwide. AutoPumps are designed to handledi�cult pumping challenges that other pumps can’t, suchas hydrocarbons, solvents, suspended solids, corrosives,temperature extremes, viscous �uids and frequent start/stop cycles. Beyond just the pump, AutoPump systems
wellhead caps and accessories to help your installation gosmoothly. This superior pumping heritage, applicationexperience and support back up every AutoPump you putto work on your project.
Max. Flow
O.D.
Length
Advantages
1. The original automatic air-powered well pump, provenworldwide over 18 years
The highest �ow rates anddeepest pumping capabilities inthe industry
Patented, proven design forsuperior reliability anddurability, even in severeapplications
Handles solids, solvents,hydrocarbons corrosiveconditions, viscous �uids andhigh temperatures beyond thelimits of electric pumps
11
AutoPump®
Bottom Inlet, Short
Pump Dimensions Specifications & Operating RequirementsL
eng
th w
ith
Sta
nd
ard
Scr
een
41"
(10
4 cm
)
Act
uat
ion
Lev
el 2
7" (
69 c
m)
Len
gth
wit
h O
pti
on
al E
xten
ded
Scr
een
Att
ach
ed 4
4."
(113
cm
)
Inlet
Air Supply
Exhaust
O.D. 3.5" (89 mm)
Liquid Discharge
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
Length Overall, w / Extended ScreenWeight
Max. Flow RatePump Volume / Cycle
Min. Actuation Level
Standard PumpMax. Depth
Air Pressure RangeAir Usage
High Pressure PumpMax. Depth
Air Pressure Range
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material2
Sizes - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrades available2 Applies to QED supplied tubing;
other tubing sources may not conform to QED fittings.
4" - Short AP4+ Bottom InletBottom3.5 in. (8.9 cm)41 in. (104 cm)44 in. (112 cm)13 lbs. (5.9 kg)13 gpm (49 lpm)* - See Flow Rate Chart0.22 - 0.36 gal (.83 - 1.36L )27 in. (69 cm)
250 ft. (76 m)5 - 120 psi (0.4 - 8.4 kg/cm2)0.4-1.5 scf / gal. (1.5 - 5.7 liters of air /fluid liter) - See air usage chart
425 ft. (130 m)5 - 200 psi (0.4 - 14.1 kg/cm2)
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, UHMWPE3, BrassStainless Steel, Viton, Acetal, PVDF4
Brass or Stainless SteelBarbs or Quick Connects
Nylon1 in. (25 mm) or 1-1/4 in. (32 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) ODNitrile3/4 in. (19 mm) or 1 in. (25 mm) ID3/8 in. (9.5 mm) ID1/2 in. (13 mm) ID
3 UHMWPE - Ultra High Molecular Weight Polyethylene4 PVDF - Polyvinylidene Fluoride
*Consult for higher flow requirements
Long and short AP4+ AutoPumps are warranted for five(5) years: 100% materials and workmanship first three(3) years; 50% materials and workmanship for the fourth(4th) and fifth (5th) years.
Low-Drawdown for the AutoPumps are warranted for one(1) year.
Application Limits(Base model)AP4+ AutoPumps are designed to handlethe application ranges described below.For applications outside these ranges,consult QED about AP4 upgrades.
Maximum Temperature: 150°F (65°C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
AP4+B
AutoPump ®
AP4+B Bottom Inlet, Short
Flow Rates 1
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivilant to 1.25-Inch O.D. Tubing)
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD 6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD18 68.1 18 68.1
16 60.6 16 60.6
14 53 5314
12 AIR INLET PRESSURES 45.4 12 AIR INLET PRESSURES 45.4
10 37.9 10 37.9
8 30.3 8 30.3
6 22.7 6 22.7
4 15.1 4 15.1
2 7.6 2 7.60 0
0 40 0 40
18 68.1 18 68.116 60.6 16 60.6
14 53 14 53
12 AIR INLET PRESSURES 45.4 12 AIR INLET PRESSURES 45.410 37.9 10 37.9
8 30.3 8 30.36 22.7
6 22.74 15.1
4 15.12 7.6
2 7.60 0
0 0
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD18 68.1 10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
18 68.116 60.6
16 60.614 53
531412 AIR INLET PRESSURES 45.4
12 AIR INLET PRESSURES 45.410 37.9
10 37.98 30.3
22.78 30.3
66
4 15.122.7
4 15.12 7.6
07.62
0 20 40 180 200 06.1 12.2 30.5 54.9 61 0 20 40 180 200
6.1 12.2 30.5 54.9 61
1FLOW RATES MAY VARY WITH SIT E CONDITIONS. CALL FOR TECH NICAL ASSISTANCE.
12
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE100 PSI7 Kg/cm 2
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
40 PSI3 Kg/cm 2
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
0FT.
0FT.20
6.1 12.2DEPTH IN WELL
206.1 12.2
DEPTH IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE100 PSI7 Kg/cm 2
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2 40 PSI
3 Kg/cm 2
DEPTH IN WELL DEPTH
IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm 2 100 PSI
7 Kg/cm 2
40 PSI3 Kg/cm 2
0FT.Meters
70 PSI5 Kg/cm 2160
36.6 42.7 48.8DEPTH IN WELL
0FT.Meters
16036.6 42.7 48.8
DEPTH IN WELL
70 PSI5 Kg/cm 2 70 PSI
5 Kg/cm 2
70 PSI5 Kg/cm 2 40 PSI
3 Kg/cm 2
70 PSI
60 80 100 120 14018.3 24.4 60 80 100 120 140
18.3 24.4
70 PSI5 Kg/cm 2 5 Kg/cm 2
60 80 100 120 140 160 180 20018.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
60 80 100 120 140 160 180 20018.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
3/4 inch (19 mm)Inside Diameter Discharge Hose
(Equivalent to 1-Inch O.D. Tubing)
0 20 40 60 80 100 120 140 160 180 200 FT.6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters 0 20 40 60 80 100 120 140 160 180 200 FT.
6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
13
AutoPump®
Bottom Inlet, Short
IN WELL DEPTH
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATESTANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
40 PSI23 Kg/cm
70 PSI25 Kg/cm
100 PSI7 Kg/cm 2
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
STANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
100 PSI7 Kg/cm 2
70 PSI5 Kg/cm 2
40 PSI3 Kg/cm 2
Air Consumption
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
AP4+B
AutoPump ®
LDAP4+B Low-Drawdown, Bottom Inlet
7.0 gpm (26.5 lpm)
3.5 in (8.9 cm)
25 in. (63.5 cm)
2.
3.
4.
5. One-year warranty
14
Description
The AP4+ Low-Drawdown Bottom Inlet AutoPump providesmaximum capabilities and �ow in a bottom inlet pump for4” (100 mm) diameter and larger wells with very shortwater columns and/or the need to pump down to as lowas 11.5 inches (29 cm) above the bottom. It is o�ered inoptional versions to handle even the most severe remediationand land�ll pumping applications, and delivers �ow rates upto 7 gpm (26.5 lpm). The AP4 + Low Drawdown Bottom InletAutoPump is complemented by the most comprehensiveselection of accessories to provide a complete system tomeet site speci�c requirements. Call QED for prompt,no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe AP4+ Low-Drawdown Bottom Inlet AutoPump is part ofthe famous AutoPump family of original automatic air-powered pumps, developed in the mid 1980s speci�callyto handle unique pumping needs at remediation and land�llsites. Over the years they’ve proven their durability atthousands of sites worldwide. AutoPumps are designed tohandle di�cult pumping challenges that other pumps can’t,such as hydrocarbons, solvents, suspended solids,corrosives, temperature extremes, viscous �uids andfrequent start/stop cycles. Beyond just the pump,AutoPump systems o�er the most complete range oftubing, hose, connectors, wellhead caps and accessoriesto help your installation go smoothly. This superiorpumping heritage, application experience and support backup every AutoPump you put to work on your project.
Max. Flow
O.D.
Length
Advantages
1. The original automatic air-powered well pump, provenworldwide over 18 years
The highest �ow rates anddeepest pumping capabilities inthe industry in a low drawdownbottom-�ll pump
Patented, proven design forsuperior reliability anddurability, even in severeapplications
Handles solids, solvents,hydrocarbons corrosiveconditions, viscous �uids andhigh temperatures beyond thelimits of electric pumps
15
AutoPump®
Low-Drawdown, Bottom Inlet
Low-Drawdown AP4+ AutoPumps warranted for one (1)year: 100% materials and workmanship.
Specifications & Operating RequirementsPump Dimensions
Liquid Discharge
Inlet
* Optional radial inlet model provides11.5" (29 cm) actuation level
Air Supply
Exhaust
O.D. 3.5" (89 mm)
Leng
th w
ith S
tanda
rd S
cree
n 25"
(63.5
cm)
Act
uatio
n Le
vel *
13"
(33.
2 cm
)
Leng
th w
ith O
ption
al Ex
tende
d Scr
een A
ttach
ed 28
" (71
cm)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
Length Overall, w / Extended ScreenWeight
Max. Flow RatePump Volume / Cycle
Max. DepthAir Pressure Range
Min. Actuation Level
Air Usage
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type Tube & Hose Options
Tubing Material2Sizes - Liquid Discharge
Pump Air SupplyAir Exhaust
Hose MaterialSizes - Liquid Discharge
Pump Air SupplyAir Exhaust
1Material upgrades available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
4" - Low-Drawdown AP4+ Bottom InletBottom ( standard plug type check valve)3.5 in. (8.9 cm)25 in. (63.5 cm)28 in. (71.1 cm)11 lbs. (5.0 kg)7 gpm (26.5 lpm)0.11 - 0.16 gal (.42 - .61L)250 ft. (76 m)5 - 120 psi (0.4 - 8.4 kg/cm2)13 in. (33.2 cm) standard outlet11.5 in. (29 cm) w/ radial inlet.32 - 2.86 scf/gal (2.2 - 21.5 liters of air/fluidliter) See air usage chart0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, UHMWPE3, BrassStainless Steel, Viton, Acetal, PVDF4
Brass or Stainless SteelBarbs or Quick Connects
Nylon1 in. (25 mm) or 1-1/4 in. (32 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) ODNitrile3/4 in. (19 mm) or 1 in. (25 mm) ID3/8 in. (9.5 mm) ID1/2 in. (13 mm) ID
3 UHMWPE - Ultra High Molecular Weight Polyethylene
4 PVDF - Polyvinylidene Fluoride
Application Limits(Base model)AP4+ AutoPumps are designed to handlethe application ranges described below.For applications outside these ranges,consult QED about AP4 upgrades.
Maximum Temperature: 150°F (65°C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
LDAP4+B
AutoPump ®
LDAP4+B Low-Drawdown, Bottom Inlet
Flow Rates 1
9 34.1 9 34.1
8 AIR INLET PRESSURES 30.3 8 AIR INLET PRESSURES 30.3
7 26.5 26.57
6 22.7 6 22.7
18.9 18.95 5
4 15.1PSI 4 15.12
3 11.4 3 11.4
7.6 7.62 2
1 3.8 1 3.8
0 00 20 40 60 80 180 200 0 20 40 60 80 100 120
6.1 12.2 18.3 24.4 30.5 36.6140
6.1 12.2 18.3 24.4 54.9 61 42.7
9 34.1 9 34.1
8 30.3 8 30.3
7 AIR INLET PRESSURES 26.5 7 AIR INLET PRESSURES 26.5
6 22.7 6 22.7
5 18.9 5 18.9
4 15.1 4 15.12
32
3 11.4 11.4
2 7.6 2 7.62
1 3.8 1 3.8
0 00 20 40 60 80 180 200 140 160 180 200
6.1 12.2 18.3 24.4 54.9 61 42.7 48.8 54.9 61 Meters
9 34.1 9 34.1
8 30.3 8 30.3
7 AIR INLET PRESSURES 26.5 7 AIR INLET PRESSURES 26.5
6 22.7 6 22.7
18.95 5 18.9
4 15.1 4 15.12 2
3 11.4 3 11.4
7.62 2 7.6
1 3.8 1 3.8
0 0140 160 180 200 FT.
42.7 48.8 54.9 61 Meters
00 20 0 20 40 60 80 100 120
6.1 12.2 18.3 24.4 30.5 36.6140 160
6.1 12.2 42.7 48.8 54.9 61 Meters
1FLOW RATES MAY VARY WITH SIT E CONDITIONS. CALL FOR TECH NICAL ASSISTANCE.
16
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD 6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 7 Kg/cm 2
100 PSI7 Kg/cm
40 PSI3 Kg/cm 2
70 PSI5 Kg/cm 2
40 PSI3 Kg/cm 2
70 PSI5 Kg/cm 2
0FT.Meters
0160 180 200 FT.
48.8 54.9 61 Meters
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
140 16042.7 48.8
DEPTH IN WELL
DEPTH IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONSGALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm
100 PSI7 Kg/cm
40 PSI3 Kg/cm
40 PSI3 Kg/cm 270 PSI
5 Kg/cm 270 PSI
5 Kg/cm 2
0FT.Meters
0FT.140 160
42.7 48.8DEPTH IN WELL
DEPTH IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm
100 PSI7 Kg/cm
40 PSI3 Kg/cm 2
40 PSI3 Kg/cm 270 PSI
5 Kg/cm 270 PSI
5 Kg/cm 2
0180 200 FT.DEPTH
IN WELL DEPTH IN WELL
100 12030.5 36.6
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
100 120 0 20 40 60 80 100 12030.5 36.6
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
6.1 12.2 18.3 24.4 30.5 36.6
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
40 60 80 100 12018.3 24.4 30.5 36.6
3/4 inch (19 mm)Inside Diameter Discharge Hose
(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose
(Equivalent to 1.25-Inch O.D. Tubing)
17
AutoPump®
Low-Drawdown, Bottom Inlet
GALLON PUMPED(SCF/GAL)
IN WELL DEPTH
STANDARDCUBIC FEET OF AIRPER
(STD L/LITER)
601.6 2.21 3.81
.3
20.2
.4
.5
4036.624.4 30.5
80 100 120
.8
.7
.6
.9
1.0
1.3
1.2
1.1
1.4
1.5
9.457.24 8.84081041 061
Meters61
2.2
FT.1.5
200
3.0
3.7
6.0
4.5
5.2
6.7
7.5
9.7
9.0
8.2
10.5
11.2
STANDARDAPPROXIMATE
LITER PUMPED
LITER OF AIR
2.6
2.1
1.7
1.6
1.8
1.9
2.0
2.2
2.3
2.4
2.5
2.7
2.8
2.9
19.4
15.7
PER12.7
13.5
12
14.2
15
16.5
17.2
18.7
18.0
20.2
20.9
21.7
7 Kg/cm100 PSI
2
270 PSI
5 Kg/cm
40 PSI3 Kg/cm 2
IN WELL DEPTH
PER
(SCF/GAL)GALLON PUMPED
CUBIC FEET OF AIRSTANDARD
.2
6.63 7.245.034.422.21 3.816.120 14040 60 80 100 120
1.5
Meters54.9 61180 200 FT.160
48.8
.5
.3
.4
3.7
2.2
3.0
.8
.6
.7
6.0
4.5
5.2
11.21.5
9.01.2
1.1
.9
1.0
8.2
6.7
7.5
1.3
1.4
9.7
10.5
LITER OF AIR13.51.8
1.6
1.7
(STD L/LITER)LITER PUMPED12
PER12.7
2.1
1.9
2.0
15.7
STANDARD14.2APPROXIMATE
15
2.4
2.2
2.3
18.0
16.5
17.2
2.7
2.5
2.6
20.2
18.7
19.4
2.8
2.9
20.9
21.7
100 PSI7 Kg/cm 2
70 PSI5 Kg/cm 2
3 Kg/cm 240 PSI
Air Consumption
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
LDAP4+B
AutoPump ®
AP4+T Top Inlet, Long
10 gpm (38 lpm)
3.5 in (8.9 cm)
57 in. (145 cm) o�ered in optional versions to handle even the most severe
o�er the most complete range of tubing, hose, connec-
2.
3.
4.
5. Five-year warranty
* Consult for higher �ow requirements
18
Description
The AP4+ Top Inlet Long AutoPump provides maximumcapabilities and �ow in a top inlet pump for 4” diameterand larger wells needing an elevated inlet, such as pumpingtotal �uids from wells contaminated with LNAPLs. It is
remediation and land�ll pumping applications, and delivers�ow rates up to 10 gpm*. The AP4 + Long Top InletAutoPump is complemented by the most comprehensiveselection of accessories to provide a complete system tomeet site-speci�c requirements. Call QED for prompt, no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe AP4 + Top Inlet Long AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s speci�cally to handle uniquepumping needs at remediation and land�ll sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle di�cultpumping challenges that other pumps can’t, such ashydrocarbons, solvents, suspended solids, corrosives,temperature extremes, viscous �uids and frequent start/stop cycles. Beyond just the pump, AutoPump systems
tors, wellhead caps and accessories to help your installa-tion go smoothly. This superior pumping heritage, applica-tion experience and support back up every AutoPump youput to work on your project.
Max. Flow
O.D.
Length
Advantages
1. The original automatic air-powered well pump, provenworldwide over 18 years
The highest �ow rates anddeepest pumping capabilities inthe industry
Patented, proven design forsuperior reliability anddurability, even in severeapplications
Handles solids, solvents,hydrocarbons corrosiveconditions, viscous �uids andhigh temperatures beyond thelimits of electric pumps
19
AutoPump®
Top Inlet, Long
Pump Dimensions Specifications & Operating Requirements
Inlet
Air Supply
Exhaust
O.D. 3.5" (89 mm)
Liquid Discharge
Len
gth
to
To
p o
f F
itti
ng
s 5
7" (
145
cm)
Act
uat
ion
Lev
el 5
2" (
132
cm)
AP4+ AutoPumps are warranted for five (5) years: 100%materials and workmanship for the first three (3) years;50% materials and workmanship for the fourth (4th) andfifth (5th) years.
Standard Application Limits(standard model)AP4+ AutoPumps are designed to handlethe application ranges described below.For applications outside these ranges,consult QED.
Maximum Temperature: 150°F (65°C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
WeightMax. Flow Rate
Pump Volume / CycleMin. Actuation Level
Standard PumpMax. Depth
Air Pressure RangeAir Usage
High Pressure PumpMax. Depth
Air Pressure Range
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material2
Sizes - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrages available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
4" - Long AP4+ Top InletTop3.5 in. (8.9 cm) OD57 in. (145 cm) OD18 lbs. (8.7 kg)10 gpm (38 lpm) - See Flow Rate Chart0.58 - 0.78 gal (2.2 - 3.0L )52 in. (132 cm)
250 ft. (76 m)5 - 120 psi (0.4 - 8.4 kg/cm2)0.35-1.1 scf / gal. (3.0-8.4 liters of air / fluid liter)
425 ft. (130 m)5 - 200 psi (0.4 - 14.1 kg/cm2)
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, Acetal, BrassStainless Steel, Viton, Acetal, PVDF3
Brass or Stainless SteelBarbs or Quick Connects
Nylon1 in. (25 mm) or 1-1/4 in. (32 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) ODNitrile3/4 in. (19 mm) or 1 in. (25 mm) ID3/8 in. (9.5 mm) ID1/2 in. (13 mm) ID
3 PVDF - Polyvinylidene Fluoride
AP4+T
AutoPump ®
AP4+T Top Inlet, Long
Flow Rates 1
18 68.1 18 68.1
16 60.6 16 AIR INLET PRESSURES 60.6
14 53 14 53
12 AIR INLET PRESSURES 45.4 12 45.4
10 37.9 10 37.9
8 30.3 8 30.3
6 22.7 6 22.7
4 15.1 4 15.1
2 7.6 2 7.6
0 0 00 20 40 0 20 40 60 80 100 120 140 160 180 200 FT.
6.1 12.2 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
18 68.1 18 68.1
16 60.6 16 60.6
14 53 14 AIR INLET PRESSURES 53
12 AIR INLET PRESSURES 45.4 12 45.4
10 37.9 10 37.9
8 30.3 8 30.3
6 22.7 6 22.7
4 15.1 4 15.1
2 7.6 2 7.6
0 0 0 00 20 40 60 80 100 120 140 160 180 200 FT.
12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
18 68.1 1818 68.168.1
16 60.6 1616 60.660.6
14 53 1414 AIR INLET PRESSURES 5353
12 AIR INLET PRESSURES 45.4 1212 45.445.4
37.910 1010 37.937.9
8 30.3 88 30.330.3
6 22.7 66 22.722.7
15.14 44 15.115.1
2 7.6 22 7.67.6
0 00 000 20 40 160 180 200 0 20 40 60 80 100 120 140 160 180 200
6.1 12.2 30.5 54.9 61 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61
1FLOW RATES MAY VARY WITH SIT E CONDITIONS. CALL FOR TECH NICAL ASSISTANCE.
20
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD 6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm 2
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2
40 PSI3 Kg/cm 2
70 PSI5 Kg/cm 2
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
0FT. DEPTH
IN WELL DEPTH IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONSGALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm 2
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2
40 PSI3 Kg/cm 2
70 PSI5 Kg/cm 2
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
DEPTH IN WELL
DEPTH IN WELL
GALLONS
PER
MINUTE
WITH
3/4-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
19 mm
I.D. HOSE
GALLONS
PER
MINUTE
WITH
1-INCH
I.D. HOSE
APPROXIMATE
LITERS
PER
MINUTE
WITH
25.4 mm
I.D. HOSE
100 PSI7 Kg/cm 2
100 PSI7 Kg/cm 2
70 PSI5 Kg/cm 240 PSI
3 Kg/cm 270 PSI5 Kg/cm 2
36.6 42.7 48.8
0FT.Meters
DEPTH IN WELL
FT.Meters
DEPTH IN WELL
70 PSI5 Kg/cm 2
70 PSI5 Kg/cm 2
40 PSI3 Kg/cm 2
6.1
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
6.1
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
60 80 100 120 14018.3 24.4
60 80 100 120 140 160 180 20018.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
3/4 inch (19 mm)Inside Diameter Discharge Hose
(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose
(Equivalent to 1.25-Inch O.D. Tubing)
0 20 40 60 80 100 120 140 160 180 200 FT.6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 61 Meters
21
AutoPump®
Top Inlet, Long
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
70 PSI
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
5 Kg/cm 2
IN WELLDEPTH
STANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
STANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
40 PSI23 Kg/cm
70 PSI5 Kg/cm 2
100 PSI7 Kg/cm 2
Air Consumption
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
AP4+T
22
AutoPump®
Top Inlet, Short
Max. Flow
O.D.
Length
9 gpm (34 lpm)
3.5 in (8.9 cm)
42 in. (107 cm)
Description
The AP4+ Top Inlet Short AutoPump provides maximumcapabilities and flow in a top inlet pump for 4” (100 mm)diameter and larger wells with shorter water columns andthe need for an elevated inlet, such as pumping total fluidsfrom wells contaminated with LNAPLs. It is offered inoptional versions to handle even the most severeremediation and landfill pumping applications, and deliversflow rates up to 9 gpm (34 lpm)*. The AP4+ Short Top InletAutoPump is complemented by the most comprehensiveselection of accessories to provide a complete system tomeet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe AP4+ Top Inlet Short AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s specifically to handle uniquepumping needs at remediation and landfill sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle difficultpumping challenges that other pumps can’t, such ashydrocarbons, solvents, suspended solids, corrosives,temperature extremes, viscous fluids and frequent start/stop cycles. Beyond just the pump, AutoPump systemsoffer the most complete range of tubing, hose, connectors,wellhead caps and accessories to help your installation gosmoothly. This superior pumping heritage, applicationexperience and support back up every AutoPump you put towork on your project.
*Consult for higher flow requirements
Advantages
1. The original automatic air-powered well pump, provenworldwide over 18 years
2. The highest flow rates anddeepest pumping capabilities inthe industry
3. Patented, proven design forsuperior reliability anddurability, even in severeapplications
4. Handles solids, solvents,hydrocarbons corrosiveconditions, viscous fluids andhigh temperatures beyond thelimits of electric pumps
5. Five-year warranty
AP4+T
23
AutoPump®
Top Inlet, Short
Pump Dimensions Specifications & Operating Requirements
AP4+ AutoPumps are warranted for five (5) years: 100%materials and workmanship for the first three (3) years;50% materials and workmanship for the fourth (4th) andfifth (5th) years.
Low-Drawdown AutoPumps are warranted for one (1) year.
Inlet
Air Supply
Exhaust
O.D. 3.5" (89 mm)
Liquid Discharge
Len
gth
to
To
p o
f F
itti
ng
s 4
2" (
107
cm)
Act
uat
ion
Lev
el 3
7" (
94 c
m)
Standard Application Limits(standard model)AP4+ AutoPumps are designed to handlethe application ranges described below.For applications outside these ranges,consult QED.
Maximum Temperature: 150°F (65°C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
WeightMax. Flow Rate
Pump Volume / CycleMin. Actuation Level
Standard PumpMax. Depth
Air Pressure RangeAir Usage
High Pressure PumpMax. Depth
Air Pressure Range
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material2
Sizes - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrages available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
4" - Short AP4+ Top InletTop3.5 in. (8.9 cm)42 in. (107 cm)17 lbs. (7.8 kg)9 gpm (34 lpm) - See Flow Rate Chart0.22 - 0.36 gal (.83 - 1.36L )37 in. (94 cm)
250 ft. (76 m)5 - 120 psi (0.4 - 8.4 kg/cm2)0.35-1.5 scf / gal. (2.4-11.3 liters of air /fluid liter) - See Air Usage Chart
425 ft. (130 m)5 - 200 psi (0.4 - 14.1 kg/cm2)
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, Acetal, BrassStainless Steel, Viton, Acetal, PVDF3
Brass or Stainless SteelBarbs or Quick Connects
Nylon1 in. (25 mm) or 1-1/4 in. (32 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) ODNitrile3/4 in. (19 mm) or 1 in. (25 mm) ID3/8 in. (9.5 mm) ID1/2 in. (13 mm) ID
3 PVDF - Polyvinylidene Fluoride
AP4+T
24
AutoPump®
00
12.2400
6.120 FT.
Meters200
61180
54.980 140120100
30.560
18.3 42.736.624.4 48.8160
2
4
7.6
15.1
IN WELL DEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
12
10
45.4
37.9
68.118
16
14
60.6
53
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
15.14
2
0
7.6
0
8
6
30.3
22.7
12
10
45.4
37.9
16
14
60.6
53
PER LITERS45.412
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
18
12.26.1
68.1
Meters8.84 9.45 1642.736.630.524.418.30 4020
2
0
FT.
0
7.6
2001801601401201008060
70 PSI25 Kg/cm
IN WELL DEPTH
WITH
MINUTE
PER
I.D. HOSE
19 mm
3/4-INCH
I.D. HOSE 6
4 15.1
22.7
WITH
MINUTE 10
8
37.9
30.3
APPROXIMATEGALLONS
16
14
60.6
53
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD18 68.1
MINUTE
I.D. HOSE
3/4-INCH
WITH
PER
GALLONS
PER
I.D. HOSE
19 mm
WITH
MINUTE
LITERS
APPROXIMATE
MINUTE
I.D. HOSE
3/4-INCH
WITH
PER
GALLONS
PER
I.D. HOSE
19 mm
WITH
MINUTE
LITERS
APPROXIMATE
AIR INLET PRESSURES
40 PSI3 Kg/cm 2 25 Kg/cm
70 PSI
7 Kg/cm 2100 PSI
40 PSI3 Kg/cm 2
5 Kg/cm 270 PSI
7 Kg/cm 2100 PSI
AIR INLET PRESSURES
40 PSI3 Kg/cm 2
100 PSI27 Kg/cm
AIR INLET PRESSURES
1FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Top Inlet, Short
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
Flow Rates1
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
8
4
0
2
6
12
10
14
16
18
206.1
4012.2
6018.3
8024.4
10030.5
12036.6
14042.7
16048.8
18054.9
20061
30.3
22.7
7.6
0
15.1
FT.Meters
53
37.9
45.4
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
60.6
68.1
0
31.75 mm
O.D. TUBING
LITERS
PER
MINUTE
WITH
APPROXIMATE
1.25-INCH
O.D. TUBING
GALLONS
PER
MINUTE
WITH
DEPTH IN WELL
4
0
2
6
8
10
12
18
14
16
15.1
0
7.6
22.7
30.3
37.9
45.4
68.1
53
60.6
DEPTH IN WELL
4
0
2
6
8
10
12
18
14
16
15.1
0
7.6
22.7
30.3
37.9
45.4
68.1
53
60.6
DEPTH IN WELL
206.1
0 16048.824.4 36.6 42.718.3
6030.5100 120 1408040
12.2 54.9180
61200
MetersFT.
206.1
0 16048.824.4 36.6 42.718.3
6030.5100 120 1408040
12.2 54.9180
61200
MetersFT.
O.D. TUBING
1.25-INCH
WITH
MINUTE
PER
GALLONS
PER
O.D. TUBING
31.75 mm
MINUTE
WITH
LITERS
APPROXIMATE
O.D. TUBING
1.25-INCH
WITH
MINUTE
PER
GALLONS
PER
O.D. TUBING
31.75 mm
MINUTE
WITH
LITERS
APPROXIMATE
AIR INLET PRESSURES
27 Kg/cm100 PSI
25 Kg/cm70 PSI40 PSI
3 Kg/cm 2
AIR INLET PRESSURES
27 Kg/cm100 PSI
240 PSI
3 Kg/cm 2
AIR INLET PRESSURES
27 Kg/cm100 PSI
2
40 PSI3 Kg/cm 2
5 Kg/cm70 PSI
5 Kg/cm70 PSI
AP4+T
25
AutoPump®
IN WELL DEPTH
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
MetersFT.
36.618.31.6 2.21 24.4 30.5 48.842.7 54.9 61
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATESTANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
40 PSI23 Kg/cm
70 PSI25 Kg/cm
100 PSI7 Kg/cm 2
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
MetersFT.
36.618.31.6 2.21 24.4 30.5 48.842.7 54.9 61
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
STANDARDCUBIC FEET OF AIR PERGALLON PUMPED(SCF/GAL)
70 PSI5 Kg/cm 2
100 PSI7 Kg/cm 2
40 PSI3 Kg/cm 2
Air Consumption
Top Inlet, Short
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
AP4+T
26
AutoPump®
Advantages
Max. Flow
O.D.
Length
6.4 gpm (24 lpm)
3.5 in (8.9 cm)
29 in. (74 cm)
Description
The Low-Drawdown AP4+ Top Inlet AutoPump providesmaximum capabilities and flow in a top inlet pump for 4”(100 mm) diameter and larger wells with very short watercolumns and/or the need to pump down to as low as 24inches (62 cm) above the bottom. It is offered in optionalversions to handle even the most severe remediation andlandfill pumping applications, and delivers flow rates up to6.4 gpm (24 lpm). The Low Drawdown AP4+ Top InletAutoPump is complemented by the most comprehensiveselection of accessories to provide a complete system tomeet site-specific requirements. Call QED for prompt, no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe Low-Drawdown AP4+ Top Inlet AutoPump is part of thefamous AutoPump family of original automatic air-poweredpumps, developed in the mid 1980s specifically to handleunique pumping needs at remediation and landfill sites.Over the years they’ve proven their durability at thousandsof sites worldwide. AutoPumps are designed to handledifficult pumping challenges that other pumps can’t, suchas solvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
1. The original automatic air-powered well pump, provenworldwide over 18 years
2. The highest flow rates anddeepest pumping capabilities inthe industry in a low drawdowntop-fill pump
3. Patented, proven design forsuperior reliability anddurability, even in severeapplications
4. Handles solids, solvents,corrosive conditions, viscousfluids and high temperaturesbeyond the limits of electricpumps
5. One-year warranty
Low-Drawdown, Top InletLDAP4+T
27
AutoPump®
Pump Dimensions Specifications & Operating Requirements
Low-Drawdown AP4+ AutoPumps are warranted for one(1) year: 100% material and workmanship.
Standard Application Limits(standard model)AP4+ AutoPumps are designed to handlethe application ranges described below.For applications outside these ranges,consult QED.
Maximum Temperature: 150°F (65°C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
Inlet
Air Supply
Exhaust
O.D. 3.5" (89 mm)
Liquid Discharge
Len
gth
to
To
p o
f F
itti
ng
s 2
9" (
74 c
m)
Act
uat
ion
Lev
el 2
4" (
62 c
m)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
WeightMax. Flow Rate
Pump Volume / CycleMax. Depth
Air Pressure RangeMin. Actuation Level
Air Usage
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material2
Sizes - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrages available2 Applies to QED supplied tubing;
other tubing sourcesmay not conform to QED fittings.
4" - Low-Drawdown AP4+ Top InletTop3.5 in. (8.9 cm)29 in. (74 cm)11 lbs. (5.0 kg)6.4 gpm (24 lpm)0.11 - 0.16 gal (.42 - .61L)250 ft. (76 m)5 - 120 psi (0.4 - 8.4 kg/cm2)24 in. (62 cm).31 - 2.85 scf/gal (2.2 - 21.5 liters of air/fluid liter) see air usage chart0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, Acetal, BrassStainless Steel, Viton, Acetal, PVDF3
Brass or Stainless SteelBarbs or Quick Connects
Nylon1 in. (25 mm) or 1-1/4 in. (32 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) ODNitrile3/4 in. (19 mm) or 1 in. (25 mm) ID3/8 in. (9.5 mm) ID1/2 in. (13 mm) ID
3 PVDF - Polyvinylidene Fluoride
Low-Drawdown, Top Inlet LDAP4+T
28
AutoPump®
Low-Drawdown, Top Inlet
00
18.9MINUTE 5
48.842.736.612.26.1 18.3 24.4 30.5 Meters9.45 16 IN WELL 160140120400 20 8060
0100 FT.200180 DEPTH
0
1 3.8
2I.D. HOSE7.6
I.D. HOSE
3/4-INCH
WITH
WITH15.14
3 19 mm11.4
MINUTE
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
GALLONS
PER LITERS6PER
22.7
7 APPROXIMATE26.5
8 30.3
9 34.1
48.842.736.612.26.1 18.3 24.4 30.5 Meters9.45 16 IN WELL16014012040 806020 100
00
0FT.200180 DEPTH
1 3.8
2 I.D. HOSE7.6
18.95
I.D. HOSE
3/4-INCH
WITH
WITH
3 19 mm11.4
4MINUTE
15.1
GALLONS
MINUTE
PER LITERS22.76
PER
7APPROXIMATE
26.5
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
8 30.3
9 34.1
Meters8.84 9.45 1642.736.6 IN WELL12.2 24.418.3 30.56.116014012040 8060 1000 20 FT.200180 DEPTH
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
1 3.8
2I.D. HOSE7.6
3/4-INCH
I.D. HOSE
WITH
3 19 mm11.4
4 WITH15.1MINUTE
26.57GALLONS
MINUTE
PER LITERS22.76
5PER18.9
APPROXIMATE
8 30.3
9 34.1
3 Kg/cm40 PSI
2 70 PSI25 Kg/cm
7 Kg/cm 2100 PSI
AIR INLET PRESSURES
3 Kg/cm 240 PSI
70 PSI5 Kg/cm 2
27 Kg/cm100 PSI
AIR INLET PRESSURES
25 Kg/cm70 PSI
3 Kg/cm 240 PSI
100 PSI27 Kg/cm
AIR INLET PRESSURES
00
18.9MINUTE 5
48.842.736.612.26.1 18.3 24.4 30.5 Meters9.45 16 IN WELL 160140120400 20 8060
0100 FT.200180 DEPTH
0
1 3.8
2 7.6 I.D. HOSE
I.D. HOSE
1-INCH
WITH15.1 WITH4
3 25.4 mm11.4
MINUTE
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
GALLONS
PER LITERS6 22.7
PER
7APPROXIMATE
26.5
8 30.3
9 34.1
48.842.736.612.26.1 18.3 24.4 30.5 Meters9.45 16 IN WELL 160140120
040 80600 20 100
0FT.200180 DEPTH
1 3.8
2 I.D. HOSE7.6
5 18.9
1-INCH
I.D. HOSE
WITH
WITH
3 11.4 25.4 mm
4MINUTE
15.1
MINUTE
GALLONSGALLONS
PER LITERS22.76
PER
7 26.5APPROXIMATE
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
8 30.3
9 34.1
Meters8.84 9.45 1642.736.6 IN WELL 12.26.1 24.418.3 30.51601401200 4020 8060 100 FT.200180 DEPTH
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
1 3.8
2I.D. HOSE7.6
1-INCH
I.D. HOSE
WITH
3 25.4 mm11.4
4 WITH15.1MINUTE
26.57GALLONS
MINUTE
PER LITERS22.76
5PER18.9
APPROXIMATE
8 30.3
9 34.1
40 PSI3 Kg/cm 2
5 Kg/cm70 PSI
2
7 Kg/cm100 PSI
2
AIR INLET PRESSURES
3 Kg/cm240 PSI
5 Kg/cm270 PSI
27 Kg/cm100 PSI
AIR INLET PRESSURES
23 Kg/cm40 PSI
25 Kg/cm70 PSI
100 PSI27 Kg/cm
AIR INLET PRESSURES
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
Flow Rates1
LDAP4+T
29
AutoPump®
Low-Drawdown, Top Inlet
IN WELL DEPTH
.2 1.5160
48.81.6 2.21 3.81 24.4 30.5 36.6 42.7021 04100108060402
Meters54.9 61180 200 FT.
.3
.4
.5
2.2
3.0
3.7
.7
.6
.8
5.2
4.5
6.0
1.0
.9
1.1
7.5
6.7
8.2
1.8 LITER OF AIR13.5
1.5 11.2
1.2
1.3
1.4
9.0
9.7
10.5
GALLON PUMPED1.6(SCF/GAL)
PER1.7
(STD L/LITER)LITER PUMPED12
PER12.7
STANDARDCUBIC FEET OF AIR
1.9
2.0
2.1
APPROXIMATESTANDARD14.2
15
15.7
2.3
2.2
2.4
17.2
16.5
18.0
2.8 20.9
2.6
2.5
2.7
19.4
18.7
20.2
2.9 21.7
7 Kg/cm100 PSI
70 PSI2
2
5 Kg/cm
40 PSI3 Kg/cm 2
IN WELL DEPTH
.2 1.5160
48.836.61.6 2.21 3.81 24.4 30.5 42.720 14040 60 80 100 120
Meters54.9 61180 200 FT.
.3
.4
.5
2.2
3.0
3.7
.7
.6
.8
5.2
4.5
6.0
1.0
.9
1.1
7.5
6.7
8.2
LITER OF AIR1.8 13.5
1.5 11.2
1.2
1.3
1.4
9.0
9.7
10.5
GALLON PUMPED1.6(SCF/GAL)
PER1.7
(STD L/LITER)LITER PUMPED12
PER12.7
STANDARDCUBIC FEET OF AIR
1.9
2.0
2.1
APPROXIMATESTANDARD14.2
15
15.7
2.3
2.2
2.4
17.2
16.5
18.0
2.8 20.9
2.6
2.5
2.7
19.4
18.7
20.2
2.9 21.7
100 PSI7 Kg/cm 2
70 PSI25 Kg/cm
40 PSI3 Kg/cm 2
Air Consumption
3/4 inch (19 mm)Inside Diameter Discharge Hose(Equivalent to 1-Inch O.D. Tubing)
1 inch (25.4 mm)Inside Diameter Discharge Hose(Equivalent to 1.25-Inch O.D. Tubing)
LDAP4+T
30
AutoPump®
Bottom Inlet, LongAP3BMax. Flow
O.D.
Length
7.3 gpm (27.6 lpm)
2.63 in (6.68 cm)
52 in. (132 cm)
Description
The AP3B Bottom Inlet Long AutoPump is designed formoderate-duty remediation pumping applications with wellcasings 3” (75 mm) diameter and larger. Call QED for prompt,no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe AP3B Bottom Inlet Long AutoPump is part of thefamous AutoPump family of original automatic air-poweredpumps, developed in the mid 1980s specifically to handleunique pumping needs at remediation and landfill sites.Over the years they’ve proven their durability at thousandsof sites worldwide. AutoPumps are designed to handledifficult pumping challenges that other pumps can’t, suchas solvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
Advantages
1. Based on the original automaticair-powered well pump, provenworldwide over 18 years
2. Competitive flow rates andpumping capabilities
3. Patented, proven design forsuperior reliability and durability
4. Handles solids, some solvents,hydrocarbons and corrosiveconditions beyond the limits ofelectric pumps
5. Two-year warranty
31
AutoPump®
Bottom Inlet, Long AP3B
AP3 AutoPumps are warranted for two (2) years:100% materials and workmanship.
Pump Dimensions Specifications & Operating Requirements
Application LimitsAP3 AutoPumps are designed to handle the applicationrange described below. For applications outside thisrange, consider the AP4 and AP2 models.
Maximum Temperature: 120˚F (49˚C)pH Range: 4-9Some solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE
Liquid Discharge
Inlet
Air Supply
Exhaust
O.D. 2.63" (6.68 cm)
extended screen adds 5"
Len
gth
wit
h S
tan
dar
d S
cree
n 5
2" (
132
cm)
Act
uat
ion
Lev
el 3
1" (
79 c
m)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
Length Overall, w / Extended ScreenWeight
Max. Flow RatePump Volume / Cycle
Max. DepthAir Pressure Range
Min. Actuation LevelAir Usage
Min. Liquid Density
Standard Construction MaterialsPump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube OptionsTubing Material
Sizes1 - Liquid DischargePump Air Supply
Air Exhaust
1 Applies to QED supplied tubing;other tubing sources may not
conform to QED fittings.
3" - Long AP3 Bottom InletBottom2.63 in. (6.68 cm)52 in. (132 cm)57 in. (145 cm)11 lbs. (5.0 kg)7.3 gpm (27.6 lpm) - See Flow Rate Chart0.23 - 0.32 gal (0.87 - 1.21L )220 ft. (67 m)5 - 100 psi (0.4 - 7.0 kg/cm2)31 in. (79 cm)0.33-1.45 scf / gal. (2.5-10.8 liters of air /fluid liter) - See Air Usage Chart
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, UHMWPE2, BrassStainless Steel, Viton, Acetal, NylonBrass or Stainless SteelBarbs or Quick Connects
Nylon3/4 in. (19 mm) or 1 in. (25 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) OD
2 UHMWPE - Ultra High Molecular Weight Polyethylene
32
AutoPump®
Bottom Inlet, LongAP3B
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELL DEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.1910 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELL DEPTH
WITH
MINUTE
PER
O.D. TUBE
19 mm
3/4-INCH
O.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
MINUTE
3/4-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
3/4-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
AIR INLET PRESSURES
100 PSI27 Kg/cm
70 PSI25 Kg/cm3 Kg/cm 2
40 PSI
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
5 Kg/cm 270 PSI40 PSI
3 Kg/cm
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
25 Kg/cm70 PSI40 PSI
3 Kg/cm 2
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELL DEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.1910 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELL DEPTH
WITH
MINUTE
PER
O.D. TUBE
25 mm
1-INCH
O.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
25 Kg/cm70 PSI40 PSI
3 Kg/cm 2
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
5 Kg/cm 270 PSI40 PSI
3 Kg/cm 2
AIR INLET PRESSURES
100 PSI27 Kg/cm
70 PSI25 Kg/cm3 Kg/cm 2
40 PSI
FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
.75 inch (19 mm) O.D.Fluid Discharge Tubing
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Flow Rates1
33
AutoPump®
Bottom Inlet, Long AP3B
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
40 PSI23 Kg/cm
70 PSI5 Kg/cm 2
100 PSI7 Kg/cm 2
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
1.3
1.4
1.5
1.6
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED(SCF/GAL)
40 PSI23 Kg/cm
70 PSI5 Kg/cm 2
100 PSI7 Kg/cm 2
Air Consumption
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
.75 inch (19 mm) O.D.Fluid Discharge Tubing
34
AutoPump®
Bottom Inlet, ShortAP3BDescription
Max. Flow
O.D.
Length
6.0 gpm (22.7 lpm)
2.63 in (6.68 cm)
42 in. (106.6 cm)
The AP3 Bottom Inlet Short AutoPump is designed formoderate-duty remediation pumping applications with wellcasings 3” (75 mm) diameter and larger. It is designed forwells having shorter water columns and/or the need topump down to lower water levels, compared to full-lengthpumps. Complete system components such as tubing andhose sets, well caps, and flow counters are available for theAP3 Long Bottom Inlet AutoPump. Call QED for prompt, no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe AP3 Bottom Inlet Short AutoPump is part of thefamous AutoPump family of original automatic air-poweredpumps, developed in the mid 1980s specifically to handleunique pumping needs at remediation and landfill sites.Over the years they’ve proven their durability at thousandsof sites worldwide. AutoPumps are designed to handledifficult pumping challenges that other pumps can’t, suchas solvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
Advantages
1. Based on the original automaticair-powered well pump, provenworldwide over 18 years
2. Competitive flow rates andpumping capabilities
3. Patented, proven design forsuperior reliability and durability
4. Handles solids, some solvents,hydrocarbons and corrosiveconditions beyond the limits ofelectric pumps
5. Two-year warranty
35
AutoPump®
Bottom Inlet, Short AP3BPump Dimensions Specifications & Operating Requirements
AP3 AutoPumps are warranted for two (2) years:100% materials and workmanship.
Inlet
Air Supply
Exhaust
O.D. 2.63" (6.68 cm)
extended screen adds 5"
Liquid Discharge
Len
gth
wit
h S
tan
dar
d S
cree
n 4
2" (
107
cm)
Act
uat
ion
Lev
el 2
2" (
55.9
cm
)Model
Liquid Inlet LocationOD
Length Overall (pump & fittings)Length Overall, w / Extended Screen
WeightMax. Flow Rate
Pump Volume / CycleMax. Depth
Air Pressure RangeMin. Actuation Level
Air Usage
Min. Liquid Density
Standard Construction MaterialsPump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube OptionsTubing Material
Sizes1 - Liquid DischargePump Air Supply
Air Exhaust
1 Applies to QED supplied tubing;other tubing sources may not
conform to QED fittings.
3" - Short AP3 Bottom InletBottom2.63 in. (6.68 cm)42 in. (107cm)47 in. (117cm)10 lbs. (4.5 kg)6.0 gpm (22.7 lpm) - See Flow Rate Chart0.08 - 0.15 gal (.30 - 0.57L )175 ft. (53.3 m)5 -80 psi (0.4 - 5.6 kg/cm2)22 in. (56 cm)0.35 - 1.6 scf / gal. (2.6-12.0 liters of air /fluid liter) - See Air Usage Chart
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, UHMWPE*, BrassStainless Steel, Viton, Acetal, NylonBrass or Stainless SteelBarbs or Quick Connects
Nylon3/4 in. (19 mm) or 1 in. (25 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) OD
2 UHMWPE - Ultra High Molecular Weight Polyethylene
Application LimitsAP3 AutoPumps are designed to handle the applicationranges described below. For applications outside thisrange, consider the AP4 and AP2 models.
Maximum Temperature: 120˚F (49˚C)pH Range: 4-9Solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE
36
AutoPump®
Bottom Inlet, ShortAP3B
FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELLDEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.1910 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELLDEPTH
WITH
MINUTE
PER
O.D. TUBE
25 mm
1-INCH
O.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
AIR INLET PRESSURES
25.7 Kg/cm80 PSI
3 Kg/cm 240 PSI
AIR INLET PRESSURES
80 PSI25.7 Kg/cm
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
25.7 Kg/cm80 PSI40 PSI
3 Kg/cm 2
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELL DEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.19
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELL DEPTH
WITH
MINUTE
PER
O.D. TUBE
19 mm
3/4-INCH
O.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
MINUTE
3/4-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
3/4-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
3 Kg/cm 240 PSI 25.7 Kg/cm
80 PSI
AIR INLET PRESSURES
AIR INLET PRESSURES
80 PSI25.7 Kg/cm
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
40 PSI3 Kg/cm 2
25.7 Kg/cm80 PSI
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
.75 inch (19 mm) O.D.Fluid Discharge Tubing
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
Flow Rates1
37
AutoPump®
Bottom Inlet, Short AP3B
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
1.8 13.5
40 PSI23 Kg/cm
80 PSI5.7 Kg/cm 2
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
1.7 12.7
40 PSI23 Kg/cm
80 PSI5.7 Kg/cm 2
Air Consumption
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
.75 inch (19 mm) O.D.Fluid Discharge Tubing
38
AutoPump®
Top Inlet, LongAP3TMax. Flow
O.D.
Optional O.D.
Length
5.4 gpm (20 lpm)
3.4 in (8.64 cm)
2.6 in (6.68 cm)
57 in. (145 cm)
Description
The AP3T Top Inlet Long AutoPump is designed for moder-ate-duty remediation pumping applications with wellcasings 3” (7.62 cm) diameter and larger using available2.63 inch (6.68 cm) inlet. It is designed for applicationsrequiring an elevated inlet, such as pumping total fluidsfrom wells contaminated with LNAPLs. Call QED forprompt, no-obligation assistance on your pumping projectneeds.
The AutoPump HeritageThe AP3T Top Inlet Long AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s specifically to handle uniquepumping needs at remediation and landfill sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle difficultpumping challenges that other pumps can’t, such assolvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
Advantages
1. Based on the original automaticair-powered well pump, provenworldwide over 18 years
2. Competitive flow rates andpumping capabilities
3. Patented, proven design forsuperior reliability and durability
4. Handles solids, some solvents,hydrocarbons and corrosiveconditions beyond the limits ofelectric pumps
5. Two-year warranty
39
AutoPump®
Top Inlet, Long AP3TPump Dimensions Specifications & Operating Requirements
AP3 AutoPumps are warranted for two (2) years:100% materials and workmanship.
Body O.D. 2.63" (6.68 cm)
Inlet O.D. 3.4" (8.64 cm)Also Available (2.63" (6.68 cm)
Inlet
Air Supply
Exhaust
Liquid Discharge
Len
gth
to
To
p o
f F
itti
ng
s 5
7" (
145
cm)
Act
uat
ion
Lev
el 5
3" (
135
cm)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
WeightMax. Flow Rate
Pump Volume / CycleMax. Depth
Air Pressure RangeMin. Actuation Level
Air Usage
Min. Liquid Density
Standard Construction MaterialsPump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube OptionsTubing Material
Sizes1 - Liquid DischargePump Air Supply
Air Exhaust
1 Applies to QED supplied tubing;other tubing sources may not
conform to QED fittings.
3" - Long AP3 Top InletTop3.4 in. (8.64 cm) (2.63 in. Available)57 in. (145 cm)11.5 lbs. (5.3 kg)5.4 gpm (20.4 lpm) - See Flow Rate Chart0.23 - 0.32 gal (0.87 - 1.21L )220 ft. (67 m)5 - 100 psi (0.4 - 7.0 kg/cm2)53 in. (135 cm)0.41 -1.59 scf / gal.(3.0 - 11.9 liters of air /fluid liter) - See Air Usage Chart
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, Acetal, BrassStainless Steel, Viton, Acetal, NylonBrass or Stainless SteelBarbs or Quick Connects
Nylon3/4 in. (19 mm) or 1 in. (25 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) OD
Application LimitsAP3 AutoPumps are designed to handle the applicationranges described below. For applications outside thisrange, consider the AP4 and AP2 models.
Maximum Temperature: 120˚F (49˚C)pH Range: 4-9Solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE
40
AutoPump®
Top Inlet, LongAP3T
FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELLDEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.1910 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELLDEPTH
WITH
MINUTE
PER
O.D. TUBE
25 mm
1-INCH
O.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
AIR INLET PRESSURES
100 PSI27 Kg/cm
70 PSI25 Kg/cm3 Kg/cm 2
40 PSI
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
5 Kg/cm 270 PSI
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
25 Kg/cm70 PSI
40 PSI3 Kg/cm 2
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELL DEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.1910 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELL DEPTH
WITH
MINUTE
PER
O.D. TUBE
19 mm
3/4-INCH
I.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
MINUTE
3/4-INCH
I.D. TUBE
WITH
GALLONS
PER
PER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
3/4-INCH
I.D. TUBE
WITH
GALLONS
PER
PER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
O.D. TUBE
AIR INLET PRESSURES
100 PSI27 Kg/cm
70 PSI25 Kg/cm3 Kg/cm 2
40 PSI
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
5 Kg/cm 270 PSI40 PSI
3 Kg/cm 2
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
25 Kg/cm70 PSI
40 PSI3 Kg/cm 2
.75 inch (19 mm) O.D.Fluid Discharge Tubing
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Flow Rates1
41
AutoPump®
Top Inlet, Long AP3T
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
100 PSI7 Kg/cm 2
70 PSI5 Kg/cm 2
40 PSI23 Kg/cm
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
100 PSI7 Kg/cm 2
70 PSI5 Kg/cm 2
40 PSI23 Kg/cm
Air Consumption
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
.75 inch (19 mm) O.D.Fluid Discharge Tubing
42
AutoPump®
Top Inlet, ShortAP3TDescription
Max. Flow
O.D.
Length
4.8 gpm (18.1 lpm)
3.4 in (8.64 cm)
47 in. (119 cm)
The AP3T Top Inlet Short AutoPump is designed formoderate-duty remediation pumping applications with wellcasings 3” (7.62 cm) diameter and larger using available2.63 inch (6.68 cm) inlet. It is designed for applicationsrequiring an elevated inlet, such as pumping total fluidsfrom wells contaminated with LNAPLs. Call QED forprompt, no-obligation assistance on your pumping projectneeds.
The AutoPump HeritageThe AP3T Top Inlet Short AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s specifically to handle uniquepumping needs at remediation and landfill sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle difficultpumping challenges that other pumps can’t, such assolvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
Advantages
1. Based on the original automaticair-powered well pump, provenworldwide over 18 years
2. Competitive flow rates andpumping capabilities
3. Patented, proven design forsuperior reliability and durability
4. Handles solids, some solvents,hydrocarbons and corrosiveconditions beyond the limits ofelectric pumps
5. Two-year warranty
43
AutoPump®
Top Inlet, Short AP3TPump Dimensions Specifications & Operating Requirements
AP3 AutoPumps are warranted for two (2) years:100% materials and workmanship.
Body O.D. 2.63" (6.68 cm)
Inlet
Air Supply
Exhaust3/8" (9 mm) O.D.
Liquid Discharge
Len
gth
to
To
p o
f F
itti
ng
s 4
7" (
119
cm)
Act
uat
ion
Lev
el 4
2" (
107
cm)
Inlet O.D. 3.4" (8.64 cm)Also Available 2.63" (6.68 cm)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
WeightMax. Flow Rate
Pump Volume / CycleMax. Depth
Air Pressure RangeMin. Actuation Level
Air Usage
Min. Liquid Density
Standard Construction MaterialsPump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube OptionsTubing Material
Sizes1 - Liquid DischargePump Air Supply
Air Exhaust
1 Applies to QED supplied tubing;other tubing sources may not
conform to QED fittings.
3" - Short AP3 Top InletTop3.4 in. (8.64 cm) (2.63 in. Available)47 in. (119 cm)10 lbs. (4.5 kg)4.8 gpm (18.1 lpm) - See Flow Rate Chart0.08 - 0.15 gal (.30 - 0.57L )175 ft. (53.3 m)5 -80 psi (0.4 - 5.6 kg/cm2)42 in. (107 cm)0.43 -1.6 scf / gal.(3.2 - 12.0 liters of air /fluid liter) - See Air Usage Chart
0.7 SpG (0.7 g/cm3)
Fiberglass or Stainless SteelStainless Steel, Acetal, HDPE, BrassStainless Steel, Viton, Acetal, NylonBrass or Stainless SteelBarbs or Quick Connects
Nylon3/4 in. (19 mm) or 1 in. (25 mm) OD1/2 in. (13 mm) OD5/8 in. (16 mm) OD
Application LimitsAP3 AutoPumps are designed to handle the applicationranges described below. For applications outside thisrange, consider the AP4 and AP2 models.
Maximum Temperature: 120˚F (49˚C)pH Range: 4-9Solvents and Fuels: gasoline, diesel fuel, BTEX, MTBE
44
AutoPump®
Top Inlet, ShortAP3T
FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELLDEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.1910 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELLDEPTH
WITH
MINUTE
PER
O.D. TUBE
25 mm
1-INCH
O.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
1-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
25 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
40 PSI3 Kg/cm 2
25.7 Kg/cm80 PSI
AIR INLET PRESSURES
80 PSI25.7 Kg/cm
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
25.7 Kg/cm80 PSI
3 Kg/cm 240 PSI
AIR INLET PRESSURES
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2
4
7.6
15.1
IN WELL DEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
8
6
30.3
22.7
34.19
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELL DEPTH
WITH
MINUTE
PER
O.D. TUBE
19 mm
3/4-INCH
O.D. TUBE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
7 26.5
5 18.9
3 11.4
1 3.8
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
3
1
2
6
4
5
7
9
8
11.4
3.8
7.6
22.7
15.1
18.9
26.5
34.1
30.3
5 7 Kg/cm
MINUTE
3/4-INCH
O.D. TUBE
WITH
GALLONS
PER
PER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
MINUTE
3/4-INCH
O.D. TUBE
WITH
GALLONS
PERPER
19 mm
O.D. TUBE
MINUTE
WITH
APPROXIMATE
LITERS
280 PSI
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
80 PSI25.7 Kg/cm
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
3 Kg/cm 240 PSI 25.7 Kg/cm
80 PSI
AIR INLET PRESSURES
.75 inch (19 mm) O.D.Fluid Discharge Tubing
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Flow Rates1
45
AutoPump®
Top Inlet, Short AP3T
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
IN WELL DEPTH
1.7 12.7
40 PSI23 Kg/cm
80 PSI5.7 Kg/cm 2
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
80 PSI
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
5.7 Kg/cm 2
IN WELL DEPTH
1.8 13.5
40 PSI23 Kg/cm
Air Consumption
1.00 inch (25 mm) O.D.Fluid Discharge Tubing
.75 inch (19 mm) O.D.Fluid Discharge Tubing
46
AutoPump®
Bottom Inlet, LongAP2BDescription
Max. Flow
O.D.
Length
2.3 gpm (8.8 lpm)
1.75 in (4.45 cm)
55 in. (139 cm)
The AP2 Bottom Inlet Long AutoPump provides maximumcapabilities and flow in a bottom inlet pump for 2” (50 mm)diameter wells. It is offered in optional versions to handleeven severe remediation and landfill pumping applications,and delivers flow rates up to 2.3 gpm (8.8 lpm). The AP2Long Bottom Inlet AutoPump is complemented by the mostcomprehensive selection of accessories to provide acomplete system to meet site-specific requirements. CallQED for prompt, no-obligation assistance on your pumpingproject needs.
The AutoPump HeritageThe AP2 Bottom Inlet Long AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s specifically to handle uniquepumping needs at remediation and landfill sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle difficultpumping challenges that other pumps can’t, such assolvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
Advantages1. The original 2” automatic air-
powered well pump, provenworldwide over 15 years
2. The industry leader in reliability,durability, flow rate and depthcapability in an automatic pumpfor 2-inch wells
3. Handles solids, hyrocarbons,solvents, corrosive conditions,viscous fluids and landfill liquids
4. One-year warranty
47
AutoPump®
Bottom Inlet, Long AP2B
AP2 AutoPumps are warranted for one (1) year:100% materials and workmanship.
Pump Dimensions Specifications & Operating Requirements
Application Limits (base model)Base model AP2 AutoPumps are designed to handlethe application ranges described below. Forapplications outside this range, consult QEDabout AP2 upgrades.
Maximum Temperature: 150˚F (65˚C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
Liquid Discharge
Inlet
Air Supply
Exhaust
O.D. 1.75" (4.45 cm)
Act
uat
ion
Lev
el 3
5" (
88.9
cm
)
Len
gth
Ove
rall,
wit
h S
cree
n 5
5" (
140
cm)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
Length Overall, w / Extended ScreenWeight
Max. Flow RatePump Volume / Cycle
Max. DepthAir Pressure Range
Min. Actuation LevelAir Usage
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material
Sizes2 - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrades available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
2" - Long AP2 Bottom InletBottom1.75 in. (4.45 cm)55 in. (139 cm)57 in. (144 cm)7.8 lb (3.6 Kg)2.3 gpm (8.8 lpm) - See Flow Rate Chart0.14 - 0.17gal (0.53 - 0.64 L)300 ft (91.4 m)5 - 130 psi (0.4 - 9.2 kg/cm2)35 in. (88.9 cm)0.38 -1.45 scf / gal. (2.8 - 10.8 liters of air / fluid liter)See Air Usage Chart
0.7 SpG (0.7 g/cm3)
Stainless SteelStainless SteelStainless Steel, Viton, PVDF3
Brass or Stainless SteelBarbs or Quick Connects
Nylon5/8 in. (16 mm) OD3/8 in. (9.5 mm) OD1/2 in. (13 mm) ODNitrile1/2 in. (13 mm) ID1/4 in (6.4 mm) ID3/8 in. (9.5 mm) ID
3 PVDF - Polyvinylidene Fluoride
48
AutoPump®
Bottom Inlet, LongAP2B
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2 7.6
FT.20018040 80 14012010060 1600 20 DEPTH
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
DEPTH IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELL DEPTH
WITH
MINUTE
PER
I.D. HOSE
13 mm
1/2-INCH
I.D. HOSE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
4 15.1
3 11.4
1 3.8
3.8
7.6
15.1
11.4
1
2
4
3
3.8
7.6
15.1
11.4
1
2
4
3
1/2-INCH
I.D. HOSE
MINUTE
WITH
GALLONS
PER
13 mm
I.D. HOSE
PER
MINUTE
WITH
APPROXIMATE
LITERS
1/2-INCH
I.D. HOSE
MINUTE
WITH
GALLONS
PER
13 mm
I.D. HOSE
PER
MINUTE
WITH
APPROXIMATE
LITERSAIR INLET PRESSURES
7 Kg/cm 2100 PSI
25 Kg/cm70 PSI40 PSI
3 Kg/cm 2
40 PSI3 Kg/cm 2
5 Kg/cm 270 PSI
7 Kg/cm 2100 PSI
AIR INLET PRESSURES
100 PSI27 Kg/cm
70 PSI25 Kg/cm
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Flow Rates1
49
AutoPump®
Bottom Inlet, Long AP2BAir Consumption
IN WELL DEPTH
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
40 PSI23 Kg/cm
70 PSI5 Kg/cm 2
7 Kg/cm100 PSI
2
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
50
AutoPump®
Bottom Inlet, ShortAP2BDescription
Max. Flow
O.D.
Length
2.0 gpm (7.6 lpm)
1.75 in (4.45 cm)
33 in. (85 cm)
The AP2 Bottom Inlet Short AutoPump provides maximumcapabilities and flow in a bottom inlet pump for 2” (50 mm)diameter wells. It is offered in optional versions to handleeven severe remediation and landfill pumping applications,and delivers flow rates up to 2.0 gpm (7.6 lpm). The AP2Short Bottom Inlet AutoPump is complemented by the mostcomprehensive selection of accessories to provide acomplete system to meet site-specific requirements. CallQED for prompt, no-obligation assistance on your pumpingproject needs.
The AutoPump HeritageThe AP2 Bottom Inlet Short AutoPump is part of thefamous AutoPump family of original automatic air-poweredpumps, developed in the mid 1980s specifically to handleunique pumping needs at remediation and landfill sites.Over the years they’ve proven their durability at thousandsof sites worldwide. AutoPumps are designed to handledifficult pumping challenges that other pumps can’t, suchas solvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to workon your project.
Advantages1. The original 2” automatic air-
powered well pump, provenworldwide over 15 years
2. The industry leader in reliability,durability, flow rate and depthcapability in an automatic pumpfor 2-inch wells
3. Handles solids, hyrocarbons,solvents, corrosive conditions,viscous fluids and landfill liquids
4. One-year warranty
51
AutoPump®
Bottom Inlet, Short AP2BPump Dimensions Specifications & Operating Requirements
AP2 AutoPumps are warranted for one (1) year:100% materials and workmanship.
Liquid Discharge
Inlet
Air Supply
Exhaust
O.D. 1.75" (4.45 cm)
Act
uat
ion
Lev
el 2
0" (
51 c
m)
Len
gth
Ove
rall,
wit
h S
cree
n 3
3" (
84 c
m)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
Length Overall, w / Extended ScreenWeight
Max. Flow RatePump Volume / Cycle
Max. DepthAir Pressure Range
Min. Actuation LevelAir Usage
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material
Sizes2 - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrades available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
2" - Short AP2 Bottom InletBottom1.75 in. (4.45 cm)33 in (85 cm)35. in (89cm)5.4 lb (3.6 Kg)2.0 gpm (7.6 lpm)0.05 - 0.08 gal (0.19 - 0.30 L)300 ft (91.4 m)5 - 130 psi (0.4 - 9.2 kg/cm2)20 in. (51 cm).39-2.58 scf/gal (2.9-19.3 liters of air/fluid litersee air usage chart0.7 SpG (0.7 g/cm3)
Stainless SteelStainless SteelStainless Steel, Viton, PVDF3
Brass or Stainless SteelBarbs or Quick Connects
Nylon5/8 in. (16 mm) OD3/8 in. (9.5 mm) OD1/2 in. (13 mm) ODNitrile1/2 in. (13 mm) ID1/4 in (6.4 mm) ID3/8 in. (9.5 mm) ID
3 PVDF - Polyvinylidene Fluoride
Application Limits (base model)Base model AP2 AutoPumps are designed to handlethe application ranges described below. Forapplications outside this range, consult QEDabout AP2 upgrades.
Maximum Temperature: 150˚F (65˚C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
52
AutoPump®
Bottom Inlet, ShortAP2B
IN WELL 48.824.4 36.6 42.718.3 30.5 54.9 61 Meters6.1 12.2200
060 80200 40 160100 120 140 180
1
0DEPTH FT.
I.D. HOSE3.8
WITH
1/2-INCH
I.D. HOSE
2
MINUTE
PER 3
MINUTE
13 mm
WITH7.6
PER
LITERS11.4
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
4
GALLONS
15.1
APPROXIMATE
1 3.8
61200
0
30.524.418.36.1 12.2 48.836.6 42.7 54.9200 60 8040 160100 120 140 180
0
IN WELL MetersDEPTH FT.
1/2-INCH
I.D. HOSE
WITH
MINUTE
2 WITH
13 mm
I.D. HOSE
MINUTE7.6
PER
PER
GALLONS
3
4
LITERS11.4APPROXIMATE
15.1
20061
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
030.518.3 24.46.1 12.2 36.6 42.7 48.8 54.9
60 800
20 40 100 120 140 160 180IN WELL MetersDEPTH
0FT.
I.D. HOSE
1
1/2-INCH
WITH2
13 mm
3.8 I.D. HOSE
7.6 WITH
MINUTE
GALLONS
MINUTE
PER 3
4
APPROXIMATE
PER
11.4 LITERS
15.1
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
3 Kg/cm40 PSI
2
5 Kg/cm 270 PSI
27 Kg/cm100 PSI
AIR INLET PRESSURES
3 Kg/cm 240 PSI
5 Kg/cm70 PSI
2
7 Kg/cm 2100 PSI
AIR INLET PRESSURES
100 PSI27 Kg/cm
5 Kg/cm70 PSI
2
40 PSI23 Kg/cm
AIR INLET PRESSURES
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Flow Rates1
53
AutoPump®
Bottom Inlet, Short AP2B
121.6(SCF/GAL)
IN WELL DEPTH 80
24.41.6 2.21 3.81
.3
.26020 40
.4
.5
.8
.7
.6
.9
1.0
1.2
1.1
1.3
1.4
1.5
Meters5.03 6.63 169.457.24 8.84
2.2
1.5160100 120 140 FT.180 200
3.0
3.7
6.0
5.2
4.5
6.7
7.5
9.0
8.2
9.7
(STD L/LITER)
10.5
11.2
2.6
2.1
CUBIC FEET OF AIR
1.7GALLON PUMPEDPER
1.8
STANDARD 1.9
2.0
2.2
2.3
2.4
2.5
2.7
2.8
19.4
15.7
LITER OF AIRPERLITER PUMPED
12.7
13.5STANDARDAPPROXIMATE
14.2
15
16.5
17.2
18.0
18.7
20.2
20.9
7 Kg/cm100 PSI
2
5 Kg/cm70 PSI
2
40 PSI3 Kg/cm 2
Air Consumption
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
54
AutoPump®
Top Inlet, LongAP2TDescription
Max. Flow
O.D.
Length
1.9 gpm (7.2 lpm)
1.75 in (4.45 cm)
57 in. (144 cm)
The AP2 Top Inlet Long AutoPump provides maximumcapabilities and flow in a top inlet pump for 2” (50 mm)diameter wells requiring an elevated inlet, such as pumpingtotal fluids from wells contaminated with LNAPLs. It isoffered in optional versions to handle even severeremediation and landfill pumping applications, and deliversflow rates up to 1.9 gpm (7.2 lpm). The AP2 Long BottomInlet AutoPump is complemented by the most comprehen-sive selection of accessories to provide a complete systemto meet site-specific requirements. Call QED for prompt,no-obligation assistance on your pumping project needs.
The AutoPump HeritageThe AP2 Top Inlet Long AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s specifically to handle uniquepumping needs at remediation and landfill sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle difficultpumping challenges that other pumps can’t, such assolvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
Advantages1. The original 2” automatic air-
powered well pump, provenworldwide over 15 years
2. The industry leader in reliability,durability, flow rate and depthcapability in an automatic pumpfor 2-inch wells
3. Handles solids, hyrocarbons,solvents, corrosive conditions,viscous fluids and landfill liquids
4. One-year warranty
55
AutoPump®
Top Inlet, Long AP2TPump Dimensions Specifications & Operating Requirements
AP2 AutoPumps are warranted for one (1) year:100% materials and workmanship.
O.D. 1.75" (4.45 cm)
Liquid Discharge
Inlet
Air Supply
Exhaust
Len
gth
to
To
p o
f F
itti
ng
s 5
7" (
144
cm)
Act
uat
ion
Lev
el 5
2" (
132
cm)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
WeightMax. Flow Rate
Pump Volume / CycleMax. Depth
Air Pressure RangeMin. Actuation Level
Air Usage
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material
Sizes2 - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrages available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
2" - Long AP2 Top InletTop1.75 in. (4.45 cm)57 in. (144 cm)7.8 lbs. (3.6 kg)1.9 gpm (7.2 lpm) - See Flow Rate Chart0.14 - 0.17 gal (0.53 - 0.64l)300 ft (91.4 m)5 - 130 psi (0.4 - 9.2 kg/cm2)52 in. (132 cm)0.38 -1.57 scf / gal.(2.8 - 11.7 liters of air /fluid liter) - See Air Usage Chart
0.7 SpG (0.7 g/cm3)
Stainless SteelStainless SteelStainless Steel, Viton, PVDF3
Brass or Stainless SteelBarbs or Quick Connects
Nylon5/8 in. (16 mm) OD3/8 in. (9.5 mm) OD1/2 in. (13 mm) ODNitrile1/2 in. (13 mm) ID1/4 in (6.4 mm) ID3/8 in. (9.5 mm) ID
3 PVDF - Polyvinylidene Fluoride
Application Limits (base model)Base model AP2 AutoPumps are designed to handlethe application ranges described below. Forapplications outside this range, consult QEDabout AP2 upgrades.
Maximum Temperature: 150˚F (65˚C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
56
AutoPump®
Top Inlet, LongAP2T
00
12.2400
6.120 FT.
Meters20061
18054.9
80 14012010030.5
6018.3 42.736.624.4 48.8
160
2 7.6
IN WELL DEPTH
FT.20018040 80 14012010060 1600 20 DEPTH
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters9.45 1630.518.3 42.736.624.4 48.8 IN WELL
0 0
PER LITERS
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
12.26.1 Meters8.84 9.45 1642.736.630.524.418.30 4020
0FT.
02001801601401201008060
IN WELL DEPTH
WITH
MINUTE
PER
I.D. HOSE
13 mm
1/2-INCH
I.D. HOSE
WITH
MINUTE
APPROXIMATEGALLONS
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
4 15.1
3 11.4
1 3.8
3.8
7.6
15.1
11.4
1
2
4
3
3.8
7.6
15.1
11.4
1
2
4
3
1/2-INCH
I.D. HOSE
MINUTE
WITH
GALLONS
PER
13 mm
I.D. HOSE
PER
MINUTE
WITH
APPROXIMATE
LITERS
1/2-INCH
I.D. HOSE
MINUTE
WITH
GALLONS
PER
13 mm
I.D. HOSE
PER
MINUTE
WITH
APPROXIMATE
LITERSAIR INLET PRESSURES
7 Kg/cm 2100 PSI
25 Kg/cm70 PSI40 PSI
3 Kg/cm 2
AIR INLET PRESSURES
7 Kg/cm 2100 PSI
5 Kg/cm 270 PSI
40 PSI3 Kg/cm 2
AIR INLET PRESSURES
100 PSI27 Kg/cm
70 PSI25 Kg/cm
40 PSI3 Kg/cm 2
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Flow Rates1
57
AutoPump®
Top Inlet, Long AP2TAir Consumption
IN WELL DEPTH
.2
.3
.4
.5
.6
.7
.8
.9
20 40 60 80 100 120 140 160 180 200
1.1
1.0
1.2
STANDARDCUBIC FEET OF AIRPERGALLON PUMPED
1.3
1.4
1.5
1.6
(SCF/GAL)
MetersFT.
36.61.6 2.21 3.81 24.4 30.5 169.457.24 8.84
(STD L/LITER)LITER PUMPED
LITER OF AIRSTANDARD
PER
2.2
1.5
3.0
3.7
5.2
4.5
6.0
7.5
6.7
8.2
9.0
10.5
9.7
11.2
12
APPROXIMATE
40 PSI23 Kg/cm
70 PSI5 Kg/cm 2
7 Kg/cm100 PSI
2
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
58
AutoPump®
Top Inlet, ShortAP2TDescription
Max. Flow
O.D.
Length
1.6 gpm (6 lpm)
1.75 in (4.45 cm)
35 in. (89 cm)
The AP2 Top Inlet Short AutoPump provides maximumcapabilities and flow in a top inlet pump for 2” (50 mm)diameter wells having shorter water columns and/or theneed to pump down to lower water levels, compared tofull-length pumps. It is designed for applications requiringan elevated inlet, such as pumping total fluids from wellscontaminated with LNAPLs. It is offered in optionalversions to handle even the most severe remediation andlandfill pumping applications, and delivers flow rates up to1.6 gpm (6 lpm). The AP2 Long Bottom Inlet AutoPump iscomplemented by the most comprehensive selection ofaccessories to provide a complete system to meet site-specific requirements. Call QED for prompt, no-obligationassistance on your pumping project needs.
The AutoPump HeritageThe AP2 Top Inlet Short AutoPump is part of the famousAutoPump family of original automatic air-powered pumps,developed in the mid 1980s specifically to handle uniquepumping needs at remediation and landfill sites. Over theyears they’ve proven their durability at thousands of sitesworldwide. AutoPumps are designed to handle difficultpumping challenges that other pumps can’t, such assolvents, suspended solids, corrosives, temperatureextremes, viscous fluids and frequent start/stop cycles.Beyond just the pump, AutoPump systems offer the mostcomplete range of tubing, hose, connectors, caps andaccessories to help your installation go smoothly. Thissuperior pumping heritage, application experience andsupport back up every AutoPump you put to work onyour project.
Advantages1. The original 2” automatic air-
powered well pump, provenworldwide over 15 years
2. The industry leader in reliability,durability, flow rate and depthcapability in an automatic pumpfor 2-inch wells
3. Handles solids, hyrocarbons,solvents, corrosive conditions,viscous fluids and landfill liquids
4. One-year warranty
59
AutoPump®
Top Inlet, Short AP2TPump Dimensions Specifications & Operating Requirements
AP2 AutoPumps are warranted for one (1) year:100% materials and workmanship.
O.D. 1.75" (4.45 cm)
Liquid Discharge
Inlet
Air Supply
Exhaust
Len
gth
to
To
p o
f F
itti
ng
s 3
5" (
89 c
m)
Act
uat
ion
Lev
el 3
1" (
79 c
m)
ModelLiquid Inlet Location
ODLength Overall (pump & fittings)
WeightMax. Flow Rate
Pump Volume / CycleMax. Depth
Air Pressure RangeMin. Actuation Level
Air Usage
Min. Liquid Density
Standard Construction Materials1
Pump BodyPump Ends
Internal ComponentsTube & Hose Fittings
Fitting Type
Tube & Hose OptionsTubing Material
Sizes2 - Liquid DischargePump Air Supply
Air ExhaustHose Material
Sizes - Liquid DischargePump Air Supply
Air Exhaust
1 Material upgrages available2 Applies to QED supplied tubing;
other tubing sources may notconform to QED fittings.
2" - Short AP2 Top InletTop1.75 in. (4.45 cm)35 in. (89 cm)5.7 lbs (2.6 kg)1.6 gpm (6.0 lpm)
.05 - .08 gal (.19 - .30 l)300 ft (91.4 m)5 - 130 psi (0.4 - 9.2 kg/cm2)31 in. (78.7 cm)0.39 - 2.59 scf/gal (2.9 - 19.3 liters/fluid liter)See air usage chart
0.7 SpG (0.7 g/cm3)
Stainless SteelStainless SteelStainless Steel, Viton, PVDF3
Brass or Stainless SteelBarbs or Quick Connects
Nylon5/8 in. (16 mm) OD3/8 in. (9.5 mm) OD1/2 in. (13 mm) ODNitrile1/2 in. (13 mm) ID1/4 in (6.4 mm) ID3/8 in. (9.5 mm) ID
3 PVDF - Polyvinylidene Fluoride
Application Limits (base model)Base model AP2 AutoPumps are designed to handlethe application ranges described below. Forapplications outside this range, consult QEDabout AP2 upgrades.
Maximum Temperature: 150˚F (65˚C)pH Range: 4-9Solvents and Fuels: diesel, gasoline, JP1-JP6,#2 heating oils, BTEX, MTBE, landfill liquids
60
AutoPump®
Top Inlet, ShortAP2T
MINUTE
I.D. HOSE
13 mm
12.240200
6.1
060 FT.160100 120 140 18080 200
42.736.618.3 24.4 30.5 Meters168.84 9.45
0
1
I.D. HOSE
3.8
1/2-INCH2
WITH
MINUTE
7.6
DEPTH IN WELL
WITH
PER
APPROXIMATE
LITERS
MINUTE
13 mm
I.D. HOSE
10 FT. (300 cm) SUBMERGENCE OF PUMP HEAD
LITERS
APPROXIMATE
1/2-INCH
GALLONS
PER 3 11.4
4 15.1
4012.2
02006.1
0140
42.7120
36.660
18.380
24.4100
30.5FT.Meters
18054.9
16048.8 61
200
1
I.D. HOSE
3.8
11.4PER 3
WITH2
MINUTE
7.6
GALLONS
4 15.1
Meters18.36.1 12.2 54.936.6 42.7 48.824.4 30.5 61
2 FT. (60 cm) SUBMERGENCE OF PUMP HEAD
402000
14012060 80 1000
FT.180160 200
DEPTH IN WELL
WITH
PER
IN WELL DEPTH
6-INCH (15 cm) SUBMERGENCE OF PUMP HEAD
APPROXIMATE
LITERS
MINUTE
13 mm
I.D. HOSE
7.62
I.D. HOSE
1
1/2-INCH
3.8
MINUTE
WITH
PER 3 11.4GALLONS
4 15.1
WITH
PER
AIR INLET PRESSURES
100 PSI7 Kg/cm 2
25 Kg/cm70 PSI3 Kg/cm
40 PSI2
40 PSI3 Kg/cm 2 70 PSI
5 Kg/cm 2
100 PSI7 Kg/cm 2
AIR INLET PRESSURES
40 PSI3 Kg/cm 2 5 Kg/cm
70 PSI2
7 Kg/cm 2100 PSI
AIR INLET PRESSURES
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
1 FLOW RATES MAY VARY WITH SITE CONDITIONS. CALL FOR TECHNICAL ASSISTANCE.
Flow Rates1
61
AutoPump®
Top Inlet, Short AP2T
DEPTH IN WELL
9.71.3
4.5.6
36.6120
.3
02 04 06 08 0016.1 12.2 30.518.3 24.4
.2
.4
.5
2.2
140 FT.061 081 0029.45 1642.7 48.8 Meters
1.5
3.0
3.7
.8
.7
.9
1.1
1.0
1.2
6.0
5.2
6.7
8.2
7.5
9.0
APPROXIMATE
(SCF/GAL)
1.4
1.5
1.6GALLON PUMPED
STANDARDCUBIC FEET OF AIRPER
1.8
1.7
1.9
LITER PUMPED(STD L/LITER)
10.5
11.2
12
LITER OF AIR13.5
12.7 PER
14.2 STANDARD
2.3
2.0
2.1
2.2
2.5
2.4
2.6
17.2
15
15.7
16.5
18.7
18.0
19.4
2.8
2.7
20.9
20.2
40 PSI3 Kg/cm 2
70 PSI5 Kg/cm 2
100 PSI7 Kg/cm 2
Air Consumption
1/2 inch (13 mm)Inside Diameter Discharge Hose(Equivalent to 5/8-Inch O.D. Tubing)
62
AutoPump®
Tubing & Hose
QED offers the choice of jacketed nylon tubing or hose sets for downwelluse, and single tubes and hoses for surface runs to fit each project’s needs.The jacketed nylon tubing is an exclusive developed by QED that encloses allof the nylon tubes inside a strippable nylon outer cover, a convenient pack-age designed to provide lighter weight, increased chemical resistance,smoother handling and a smaller profile in the well. For applications wherethe tighter bend radius of hose is preferred, hose sets are offered in severalsizes. Other hose and tube materials are available for special applications.
The choice of hose and tube connection fittings used on pumps, caps andother components can make an important difference in the ease and qualityof installation and service on your project. That’s why QED offers a variety ofconnecting fitting types and materials, including quick-connects in both brassand stainless steel.
Note: All QED tube, hose and fitting combinations are engineered specificallyto provide user safety, high pullout strength, ease of installation, andleak tight connections for maximum assurance that the pumpingsystem goes in right and stays trouble-free. It is especially importantthat the mating diameters and the tolerances of fittings, tubes andhoses be carefully controlled to ensure a fit that is snug yet doesn’tdamage the hose or tube due to excessive stretching. Don’t trust yourproject to general purpose tubing, hose, and fittings that weren’tspecifically designed to work together.
AdvantagesAll dimensions of QED tube, hoseand fittings are carefully designedand controlled to ensure high flowcapacity, easy assembly, highpullout strength and leak-tightconnections
Innovative jacketed nylon tubing ishighly regarded by experiencedusers for its light weight, smoothprofile and ease of handling
QED offers an unmatched rangeof connector fitting options tomake installation and maintenanceeasier and more efficient
Model Type MaterialLiquid
DischargeSize
TypeAir
SuppySize
ExhaustSize
MaximumPressure
MaximumDepth
MinimumBend
Radius
HIFLOTUBE Jacketed 3-Tube set Nylon 12 1.25” OD 1/2” OD 5/8”OD 200 PSI 400 feet 8”(32 mm) (13 mm) (16 mm) (14 kg/cm2 (122 m) (20 cm)
STDTUBE Jacketed 3-Tube set Nylon 12 1” OD 1/2” OD 5/8”OD 200 PSI 400 feet 7”(25.4 mm) (13 mm) (16 mm) (14 kg/cm2) (122 m) (18 cm)
AP2TUBE 3-Tube set Nylon 12 5/8” OD 3/8”OD 1/2”OD 200 PSI 400 feet 2.5”(16 mm) (9.5 mm) (13 mm) (14 kg/cm2) (122 m) (6.5 cm)
HIPSIHOSE 3-hose set Nitrile 1” ID 3/8”ID 1/2”OD 300 PSI 600 feet 8”(25.4 mm) (9.5 mm) (13 mm) (21 kg/cm2) (183 m) (20 cm)
HIFLOHOSE 3-hose set Nitrile 1” ID 3/8”ID 1/2”OD 100 PSI 200 feet 8”(25.4 mm) (9.5 mm) (13 mm) (7 kg/cm2) (61 m) (20 cm)
STDHOSE 3-hose set Nitrile 3/4” ID 3/8”ID 1/2”OD 300 PSI 600 feet 7”(13 mm) (9.5 mm) (13 mm) (21 kg/cm2) (183 m) (18 cm)
AP2HOSE 3-hose set Nitrile 1/2” ID 1/4”ID 3/8”ID 300 PSI 600 feet 5”(13 mm) (6 mm) (9.5 mm) (21 kg/cm2) (183 m) (13 cm)
63
AutoPump®
AutoPump Well Caps
Hundreds of wellhead cap and flange combinations areavailable from QED on a standard and custom basis tofit site needs and ease installation and maintenance.The table below lists some of our most commonlychosen wellhead assemblies. Our assemblies are basedon the know-how gained through our 20 years experienceand thousands of installations. Besides connectingto the pump tubing or hose, wellheadassemblies have to be designed forsafety, equipment support strength,pump level adjustment, access for dataand sample collection, and durability.Call us for more detailed information.
Quick connect fittingavailable in brass orstainless steel
Compression fittingfor pass-through hoseor tubing. Available innylon
Custom flange
Vacuum seal well capwith brass quick connects,
filter regulator andpump cycle counter
WellheadAssembly
DescriptionFitting
Materials Well DiametersFitting Types(hose & tubing)
Non-sealing cap with open pass-through holes for hoses; allowseasy pump height adjustment withsupport rope/cable
Non-sealing cap with fittings forconnection to air supply and liquiddischarge lines
Sealing cap with fittings forconnection to air supply andliquid discharge lines
Sealing flange with fittings forconnection to air supply and liquiddischarge lines
Open-hole cap
Slip
Vacuum Seal
Flange
2”, 4”, 6”, custom(50, 100, 150 mm)
2”, 4”, 6”, custom(50, 100, 150 mm)
2”, 4”, 6”, custom(50, 100, 150 mm)
Custom
Brass, SS, poly
Brass, SS, poly
Brass, SS, poly
No fittings
quick-connects,compression fittings
quick-connects,compression fittings
quick-connects,compression fittings
Filter Regulatorsee page 89
Pump Cycle countersee page 88
Vacuum Cap Seal
64
AutoPump®
Flow Counters
Cycle CounterThe Cycle Counter detects and displays each AutoPump cycle via the pulse of air that occurs in the supply line.Since the liquid volume delivered by each pump cycle is relatively consistent for a given well condition, the totalliquid volume delivered can be monitored with these cycle counts. An important advantage of the Cycle Countermethod is its long-term reliability and low maintenance, since it requires no contact with the pumped fluid and noextra components in the liquid flow path. Cycle Counters can also be ordered with an electronic pulse output tosupport automated flow data collection.
Cycle Counter SpecificationsType: Magnetic piston/springReadout: Direct digital (remote option), non-resettableMaximum Pressure: 200 psi (14 kg/cm2)End options: NPT, barb, quick connect
65
AutoPump®
Air Supply
Filter regulatorsFilter regulators are recommended for each pump at the wellhead to economize on system airconsumption, allow control of pump flow rate, and reduce service needs caused by air system
debris and contaminants. These high quality filter regulators are coated on the inside toprevent corrosion from condensed moisture. All QED well caps and flanges include mountingprovisions for these filter regulators, and other mounting options are available.
Compressor SizingA compressed air supply is required to power AutoPumps. Estimation of the fluid flow ratesand air consumption of the AutoPumps and sizing the fluid lines, air lines, and air compres-
sor involves a number of factors. Our application specialists are ready to assist you.
The flow rates and air consumption for the AutoPumps can be compared by using the charts providedin this catalog for each model. The flow rate and air use curves in this catalog are based on pumpingto atmospheric pressure at the wellhead, and do not take into account any liquid piping systembackpressures due to elevation changes or fluid friction.
Finally, there are some initial guidelines for air compressors. Most importantly, follow all applicationguidelines of the compressor manufacturer. A piston compressor may be a start / stop type or a constant
run type. The tank (receiver) must be large enough, particularly for the start / stop type. The motor should not turn on moretimes an hour than recommended by the manufacturer. And start/stop compressors are typically assigned a 50% maximumduty cycle, meaning that the compressor is sized to provide twice the maximum air demand of the entire AutoPump system.
Rotary screw compressors are designed for constant operation, and so are sized to just slightly exceed the maximum airsupply requirement; it is recommended that rotary screw compressors not be grossly oversized because some types may bedamaged by continued operation at low partial capacity.
66
AutoPump®
Tank Full Shutoffs
QED’s Tank-Full Shutoff senses when your recovery tank is full and automatically shuts off the pump air supply.It is all pneumatic for safety, and includes two independent level detection methods for failsafe operation.The Tank-Full Shutoff threads into standard 2” NPT fittings on drums and tanks.
Tank Full Shutoff Specifications:Power Supply: Fully pneumaticLevel Sensor Type: Dual; Bubbler tube and float switchAir Usage: 0.7 scfm @ 80 psi (19.8 lpm @ 5.6 kg/cm2)Tank Connection: 2-inch male NPT
x xx xxx xx xxx
x xx xxx xx xxxx xx xx xxx xxx
xxxxxxxxxxx xxxxxxxxxxx
xxxxxxxxxxx xxxxxxxxxxx
0
1
0
TANK FULL
TANK FULLTANK FULL
SENSOR
RESETND CATOR
PRODUCTRECOVERY
OIL / WATER
TANKSURGE TANK
COMPRESSOR
SEPARATOR
Additional Single Sensor
Optional TFSOUnit Lengths Are
Available ForDifferent TankConfigurations
Air Supply To
Air Filters / Regulators
Pumps And / Or OtherControl Panels
TFSO Units Can Be Added
Standard TFSOUnit
Dual TFSO Sensor Hose
To The System
Wall MountingControl Panel12" x 14" x 11"
Dual-Sensor Tank-Full Shut-Off (TFSO) System
(30.5cm x 35.6 cm x 27.9 cm)(20 lbs.) (9.1 kg)
67
AutoPump®
Application Data Sheet
Address:
Name: Title:
Company:
Email:
Phone: FAX:
Address:
Company:
Site Name:
Project Ref:
Phone: FAX:
SITE INFORMATIONCUSTOMER INFORMATION
Site Information FormQED USE ONLY Quote Number
Today's Date
Sales Order NumberP.O. Box 3726 Ann Arbor, MI 48106-3726 USA 1-800-624-2026 FAX (734) 995-1170 info@qedenv.com www.qedenv.com
SENSORS REQUIRED APPLICATION TYPE
Tank-Full Shut-Off
High-Water Shut-Off
Fluid Level
Pump Cycle Counter
Total Fluids
DNAPL
Dual Pump
LNAPL
Condensate
Leachate
APPLICATION DESCRIPTION
Please attach sketch of site, well and equipment layout.
Properties of pumped fluids contaminants/viscosity/concentrations/pH/temperature/specific gravity/TDS ( . )attach additional information
Pumping Objectives ( ).attach additional information and diagrams
Note: Please note any special characteristic on illustration above
DAB
F
G
JDNAPL
LNAPL
Water
C
H
M
I
N
E
K
L
Well casing ID at wellheadWell casing ID at location of equipment
Well casing OD
Well casing to top of outer / vault casing
Vault DimensionsVault Depth
Desired fluid pumping rate
Casing MaterialsWell angle off vertical (% or degrees)Exhausting inside or outside the wellWell under vacuum (Hg or H2O)Any known material degradation (yes/no)
Depth to top of screen
Depth to top of LNAPL layer (if present)LNAPL thickness (if present)
Depth to static water level
Final drawdown level
Depth to bottom of the screen
Depth to bottom of the well
LNAPL removal rate (if present)
Water / Leachate removal rate
Sump length
DNAPL removal rate (if present)
DNAPL thickness (if present)
Maximum daily water table fluctuation
ABCDEFGHI
JKLMN
WELL IDENTIFICATION NUMBER
WELL DATA
The information provided on this form will be kept confidential by QED.
Environmental SystemsA division of Severn T ent Laboratories, Inc.
AutoPump®
Notes
AutoPump®
Warranty
AutoPump®
QED AutoPump Warranty Period Summary
Following is a summary of the warranty periods only for QED AutoPumps and accessories;this IS NOT the complete warranty. Contact QED for a copy of the complete warranty
1. AP4+ AutoPumps (Long and Short lengths; Top- and Bottom-Inlets)warranted for five (5) years: 100% materials and workmanship; AP4+ Low-DrawdownAutoPumps®
warranted for one (1) year: 100% materials and workmanship.
2. AP3 AutoPumps (Long and Short lengths; Top- and Bottom-Inlets)warranted for two (2) years: 100% materials and workmanship.
3. AP2 AutoPumps (Long and Short lengths; Top- and Bottom-Inlets)warranted for one (1) year: 100% materials and workmanship.
4. Hoses, Tubing, Fittings, Well Caps and Flangeswarranted for one (1) year: 100% materials and workmanship.There will be no warranty for application or material compatibility.
5. Pneumatic Data Modules / Logic Control Panelswarranted for one (1) year: 100% materials and workmanship.
6. Parts and Repairswarranted for ninety (90) days: 100% materials and workmanship; when repairs areperformed by QED or its appointed agent; from date of repair or for the full term ofthe original warranty, whichever is longer. Separately sold parts are warranted forninety (90) days: 100% materials and workmanship.
Beyond the Pumps…Success with a pumping system involves more than just the pumps.Over 20 years of specialized air-powered pumping experience onthousands of sites with a broad range of applications andgroundwater issues has allowed us to develop unequalled expertiseand problem solving capabilities.
QED technical experts will work with you on identifing the relevantsite information to assure meeting your remediation and landfillpumping objectives. The equipment will be selected to meet yoursite-specific application.
AccessoriesDownwell hose and tubing
An array of connectors and fittings for ease of installation and service
Mix of wellhead assemblies to meet site-specific needs
Fluid discharge and air supply piping layouts and components
Tank-full shut-off and other safety items and features
Pump cycle counters
Custom requirements
©2014 Thermo Fisher Scientific Inc. All rights reserved.
Australia: For customer service, call 1300-735-295 Visit us online at: www.thermofisher.com.auNew Zealand: For customer service, call 0800-422-469 Visit us online at: www.thermofisher.co.nz
top related