Better with VIAVI
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 2
Agenda
▪ Introduction by Synergix & VIAVI
▪ Fiber Certification:
▫ Inspect Before You Connect (IBYC™) and the risks of not doing it
▫ Cut your Tier 1 Test and Certification time in half
▫ Making Tier 2 Certification simple and easy even for novice technicians
▪ Break
▪ Service Activation & SLA Validation
▫ Validating the Quality of Service (QoS) and delivering KPIs
▪ Hands-on and time to discuss your requirements with our Experts!
▪ Lunch and end of Workshop
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 3
Enterprise Test & Certification
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 4
$900Min FY15 Revenue
7 Continents where we serve
customers
45Global Offices
3,200Expert Employees
Industry’s Largest Manufacturer
of test & certification solutions
Trusted Partnerof service providers and enterprises worldwide
Viavi Solutions
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 5
Viavi End-to-End Visibility
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 6
Technology Leadership
▪ Leading edge solutions utilized by the most advanced networks on the planet▪ Collaboration with NEMs and large service providers provide unique insight and experience to develop
solutions that are years ahead of current enterprise standards
EnterpriseWireline Service Providers
Wireless Service Providers
New Equipment Manufacturers
Cloud Providers
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 7
Technology Leadership
▪ Technologies such as 100/400 Gb and testing parallel optics connectivity (MPO) are front and center of Viavitechnology development
▪ Technology intelligence beyond the regular demands of the enterprise market
Viavi Test & Certification Innovation
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 8
Technology Leadership
▪ Active member of all major standards groups and bodies▪ We have a seat at the table and a voice in the conversation
as these standards are set, including:
European Telecom Standards Institute
Alliance for Telecommunications
Industry Solutions
✓ TIA-568✓ IEC 61280-4-1✓ ISO-11801✓ TIA-526-7✓ IEC-61300-3-35
Fiber Certification
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 10
In a recent study by NTT-Advanced Technology, 98% of installers (blue) and 80% of network owners (red) reported that issues with connector contamination was the greatest cause of network failure.
Causes of Network Failure
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 11
Dirt Damages Fiber!
▪ Once embedded debris is removed, pits and chips remain in the fiber.
▪ These pits can also prevent transmission of light, causing back reflection,insertion loss and damage to other network components.
Most connectors are not inspected until the problem is detected… AFTERpermanent damage has already occurred.
Mating dirty connectors embeds the debris into the fiber.
Core
Cladding
Back Reflection Insertion LossLight
DIRTPITS(permanent damage)
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 12
Contamination and Signal Performance
Fiber Contamination and Its Effect on Signal PerformanceCLEAN CONNECTION
Back Reflection = -67.5 dBTotal Loss = 0.250 dB
1
DIRTY CONNECTION
Back Reflection = -32.5 dBTotal Loss = 4.87 dB
3
Clean Connection vs. Dirty ConnectionThis OTDR trace illustrates a significant decrease in signal performance when dirty connectors are mated.
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 13
Inspect Before You Connectsm
Follow this simple “INSPECT BEFORE YOU CONNECT” process to ensure fibre end faces are clean prior to mating connectors.
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 14
Standards and Zones
▪ ZONES are used to prioritize evaluationcriteria.
Zone A: Core ZoneZone B: Cladding ZoneZone C: Adhesive ZoneZone D: Contact Zone
▪ Different failure criteria for defects andscratches are specified for each zone:
• Quantity and Size• Location relative to core
Zone A
Zone DZone B
IEC 61300-3-35 – “Fibre Optic Connector Endface Visual and Automated Inspection” has recently been published as an interoperability standard for connector manufacturers and users.
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 15
Proactive vs. Reactive Inspection
PROACTIVE INSPECTION:Visually inspecting fibre connectors at every stage of handling BEFORE mating them.
Connectors are much easier to clean prior to mating, before embedding debris into the fibre.
REACTIVE INSPECTION:Visually inspecting fibre connectors AFTER a problem is discovered, typically during troubleshooting.
By this time, connectors and other equipment may have suffered permanent damage.
Dirty Fibre PRIOR to MatingFibre AFTER Mating and Numerous Cleanings
Dirty Fibre PRIOR to MatingFibre AFTER Cleaning
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 16
FiberChek Probe: Inspection Requirements today
▪ Connect to other devices Bluetooth, WiFi, and USB▪ Pair with Mobile Devices using with the
FiberChekMOBILE app▫ Available for both iOS & Android
▪ Integrate with multiple Test Devices▪ Automated Pass/Fail Analysis▪ Generate Certification Reports
PC/Laptop
Certifier40G
SmartClass Fiber TBERD 2K/4K/6K Android & iOS DevicesHST-3000
MTS 5800 OneExpert
CellAdvisor
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 17
OLTS-85…What is it?
▪ Optical Loss Test Set▫ Complete Tier 1 fiber testing to TIA/ISO/IEC standards▪ Measure Length, Optical Loss, & Check Polarity▪ SM, MM (EF), and Quad versions
▫ Kits include Local & Remote units▪ Full control at both the local & remote ends▪ Remote communicates results back to local
▪ Provides FULL endface inspection at BOTH ends▫ Includes Patch Cord Microscope versions▫ P5000i Probe microscope▫ Reporting via FiberChek PRO and J-Report
▪ Part of the SmartClass Fiber product family▫ Turns any user into a fiber-smart technician▫ Powerful and easy-to-use▫ Makes it easy for technicians to do the job correctly
▪ Ideal for customer’s that do not need copper certification▫ Certifier40G for those that need copper
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 18
Provides Complete Tier 1 Fiber Certification
• Tier 1 fiber certification
• Measure Length• Measure Loss (2 fibers, 2 wavelengths)
• Ensures Loss does not exceed a “limit”(AKA loss budget)• Check Polarity
• Ensure transmit & receive ends are correct
• Document results
• End-face inspection is also a requirement
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 19
▪ Complete Tier 1 Fiber Testing (including Inspection)▫ Length▫ Loss▫ Polarity▫ Fiber end-face Inspection
▪ Optimize Workforce Efficiency▫ User control from both Local & Remote units▫ Shared archiving between Local & Remote units▫ Fully automated Pass/Fail Analysis Testing▫ Intuitive Touch-Screen User Interface▫ Integrated Inspection for both Bulkheads & PatchCords▫ Tests multiple connector types▫ Light weight – hands free carrier available▫ Instant on (from sleep mode)▫ 3 year calibration cycle▫ Power meter and Light source applications
▪ Certification Reporting▫ Integrates with FiberChekPRO
Value Proposition Summary
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 20
What is in a Kit?
▪ Two OLTS-85 Tier-1 Optical Loss Instrument – SM, MM, or Quad. Each with:▫ Single mode TX connector – SC▫ Multimode TX connector – FC▫ Shared Rx Connector – LC▪ All connectors are standard SmartClass Fiber Interchangable connectors▪ Available in most other common connectors
▫ PS4 Power supply for SCF▫ RBP2 Rechargeable Battery Pack▫ USB cable USB-A to Micro-USB▫ Hands-free carrier
▪ SC-3 Soft Shoulder Case, for SmartClass Fiber▪ Quick Start Guide▪ Mating sleeve for "LC/LC" ▪ Test Reference Cords (TRCs) for testing installed LC fiber cabling
▫ (Single mode and Multimode as appropriate)▫ SC TRCs available
▪ PCM version has duplex LC Patch Cord Microscope FMAE adapter▫ FMAE adapters in all other common connectors available
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 21
Summary of Reference Methods
Light Source Power MeterTRC TRC
One cord
Two cord
Three cord
▪ Difference is the number of bulkhead (coupler) connections included in theloss measurement.
▪ Use the method recommended by your local standards OR by your vendor!▪ For link testing, 1 cord method is universally recommended
Losses included in measurement based on reference method
Fiber System under Test
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 22
Industry Overview: Testing Enterprise networks
Growth of technicians working with fiber• New to Fiber / New to industry
• Frequent contractor turnover
New industry practices & architectures utilizing MPO connectors• Strict Loss Budgets <.5db loss per connection
• No room for mistakes
• Plug & Play Cassettes / PON / POLAN
Connectivity Requirements are Standardized• IEC 61282-15 (technical report: MPO testing)
• IEC-61300-3-35 (fiber connector end face quality)
• TIA 568/ IEC 11801 (fiber premises cabling)
• TIA 942 / IEC 24764 (datacenters)
Companies transitioning techs to mobile/tablets and cloud storage• Less expensive / Portable
• Can perform multiple job related functions (Phone / email / job tickets, store results, etc.)
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 23
Why inspection is essential for MPO
Particle of Dirt
Air Gap
12
3
45
6
7
89
1011
12
Dirt
Back Reflection
Insertion Loss
Contaminated
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 24
Image property of CommScope
1 contaminated MPO connector = exponential problems
Back = MPO
Front = Simplex
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 25
100% Autonomous portable MPO end face inspection
• Fully autonomous operation• No need for any additional devices• Built-in fiber end face analysis• Integrated touch screen display with live fiber viewing• On-Board storage: up to 100 connectors (1,200+ fibers)• Battery life ~6 hours (typical duty cycle)
• Can also connect to external devices via WiFi• PC/laptop• Android™• iOS• Viavi test mainframes TBD
• USB connection also available• Connect to PC/Laptop• Device Charging
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 26
Industry’s fastest MPO inspection workflow▪ Automatic results for all 12 MPO fibers in < 12 seconds!
▫ Auto Focus + Pan + Capture + Analyze▪ Intuitive user interface for technicians of any skill level▪ View results for each individual fiber▪ Reduce complexities of scrolling to each individual fiber
The ONLY True Automated Pass/Fail MPO inspection solution
I just thought I would get all of the MPO reference/test cords cleaned and ready to go. THIS IS A
NIGHTMARE. I can honestly say I hate testing MPO cable. I get one clean and the next one is dirty,
then I get that one clean and the first one is dirty again. - Field Contractor
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 27
Industry’s fastest MPO inspection workflow
Step Time
Focus Image 0:04
Scroll/Pan to fiber 0:04
Test ONE fiber 0:03
Save 0:02
TOTAL (1 fiber) 0:13
TOTAL (12 fibers) 2:36
Legacy MPO Inspection Process Sidewinder MPO Inspection Process
Step Time
Focus Image 0:01
Scroll/Pan all fibers 0:05
Tests all 12 fibers 0:05
Save 0:01
TOTAL (12 fibers) 0:12
Test 100 MPO Connectors in ~ 4.3 hours Test 100 MPO Connectors in 20 minutes
x12 Press Button
28
Product Overview: MPOLx
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 29
The industry’s first true Tier 1/Basic MPO certification tester
MPOLx is the first native MPO test solution…• …to measure length + loss + polarity + end face inspection together• …with full control and visibility at both the source and meter• …to provide dual-wavelength sources (850/1300 & 1310/1550)• …with built in microscope for MPO trunk cables & patch-cords
MPOLSOptical Light Source
MPOLP Optical Power Meter
Technology Leadership
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 30
Intuitive user interface for technicians of any skill level
▪Create & Manage Test Profiles*▫ Loss & Length Limits▫ Reference methods▫ Wavelengths
▪ Initiate auto tests & view results▫ Length, Loss & Polarity on a single screen▫ Complete test results in <6 seconds▫ Additional views with MPO test details
▪View & manage label lists▪ Inspect fiber end faces▪Store & Recall test results• 3.5” Color touch screens
• Available on source & meter• Both source and meter show the
same information
* or get test assignments directly from CERTiFi
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 31
View detailed test results for each individual fiber
• Test limits• Individual loss values & margins• Color coded results
• Green = PASS• Grey = WARN• Red = FAIL
• Both numeric and graphical result views• Latest firmware includes Light Source/Power
Meter
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 32
MPO Channel Selection & Polarity results
• Individual channel selection for specific fibers of an MPO• Test to 40GBASE-SR4 limits that don’t require testing all 12
lanes.
• View detailed Polarity results for individual MPO fibers• Polarity Types (A, B, or C) with visual example• Compare actual vs. expected polarity
40G BASE-SR4 Lane Assignments
33
VIAVI Tier-2 Portfolio
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 34
Viavi Portfolio: Tier-2 certification of SM and MM fibersTest, troubleshoot and document LANs/WANs, Enterprise networks and Data Centers
SmartOTDRE126B-PC
T-BERD/MTS-2000/4000with QUAD or MM
OTDR Module
T-BERD/MTS-6000A with EVO A OTDR
Module
Ultra-short event and attenuation dead-zones enable to precisely locate events and faults on short fiber links (EVO A)
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 35
New High Resolution Multimode OTDR Module
▪ New Multimode OTDR module for T-BERD/MTS-6000/8000 platforms with high performance features
Module type EDZ (m) ADZ (m) DR (dB RMS) at 1ns
E8123Av (850 nm/1300nm) MM: 0.2 MM: 0.4 / 1 16
Green trace = 8123AV
Blue trace = TraditionalOTDR
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 36
Viavi Tier 2 Test SolutionsSpecifications & Order Information
SmartOTDRE126B-PC
T-BERD/MTS-2000/4000 w\ QUAD / MM OTDR Modules
T-BERD/MTS-6000AV2 w\ EVO A
OTDR ModulesEnterprise-SLM Ready
Dead Zones (EDZ/ADZ) SM: 0.9 / 2.5 m SM: 0.9 / 4 mMM: 0.8 / 4 m
SM: 0.6 / 2 mMM: 0.2 / 1.5 m
Dynamic RangeSM (1310/1550 nm)MM (850/1300 nm)
SM: 40/40 dB SM: 40/38 dBMM: 26/24 dB
SM: 40/40 dBMM: 24/24 dB
Other applications Access/FTTH FTTA/DAS Metro/FTTHEncircled Flux Source N/A x
MPO Cassettes Front/Back Connector Measurement
x x
37
Enterprise-SLM features
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 38
Single fiber OTDR testing
Load an Enterprise SmartConfigTM file
Pre-defined configurations with set of labels or blank label scheme
1
2 Complete additional information (Fiber types (IOR), Launch / receive cables, Alarm thresholds (standards or users), Site properties, Report format, Label structure, File naming convention)
▪ No test configuration is required likeon traditional OTDR devices: range,pulsewidth, acquisition time ….
▪ Enterprise-SLM automatically sets theoptimum acquisition parameters
▪ SmartConfig keeps setup consistencyaccross installers / contractors
▪ Simple 3-steps operation
3
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 39
Project Management
Configure
•Load a pre-defined or existingproject
•Create project on-board using a listof Cable Ids / Labels
Measure•Start OTDR acquisition, analyzeand view SLM results
Control•Visualize and control pass/failstatus of all tested fibers and labels
Report
•Report OTDR fiber results (.sor &.pdf)
•At project closure generate acomprehensive summary report
▪ Task Management:▫ Manage tasks over multiple
days▫ See percentage of tests
completed▪ Manage up to 1000 fibers to be
Tier-2 certified▪ Automatically save test results
with labels from the list▪ See percentage of job
completed▪ Mandatory for MPO and duplex
cables
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 40
Multi-fiber/channel OTDR testing
Using a pre-defined or existing Project Creating a Project
Load a Project file containing a list of labels to be tested and test profile
1 Load Config. ENTERPRISE_Custom_List1
2
3
In the Project view select the label or fiber to be tested.
2 Pre-set configuration andparameters are used
3 In the Project view select thelabel or fiber to be tested.
4 5
In one of the setup menu, Import Label List from a .csv file
Modify the setup menus (Acquisition,Alarms, Site Info / Fiber Count & File)
4
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 41
Fiber Count
Fiber Count is a necessary setting to create the project
Simplex (single fiber strand)
Duplex (dual fiber strand)
MPO (8/12)
MPO (12/12)
MPO (20/24)
MPO (24/24)
Example of project with custom label list and Fiber Count set to MPO (8/12)
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 42
Transmission over Multimode Fiber
1 GbE10 GbE
MPO
MPO
MPO
MPO
MPO
MPO
Dup
lex
LC
DuplexLC
40 GbE
100 GbE
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 43
Result View – OTDR and SLM Summary View
Total link loss and ORL
Summary of faulty events
Intuitive icon-based map view
Global P/F Verdict
Total link length
“Event diagnostic” key suggests corrective actions for resolving fiber problems when a fault is detected.
Toggle between OTDR trace view and
SLM map view
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 44
Result View – SLM Event View
Detailed results for each event(location, loss and reflectance per tested
wavelength)
Event identification and analysis with a clear P/F verdict
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 45
Tier 2 Certification Report Example
Endface Inspection (pass/fail to IEC std)
General OTDR Settings
OTDR Alarm Thresholds (per
TIA/IEC std)
OTDR Link Performance Summary
OTDR Schematic Link View
OTDR Detailed Trace(s)
OTDR Detailed Event Table
General Report & Job Information
w/ Pass/Fail indication
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 46
Tier-2 Project Summary Report Example
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 47
40G/100G MPO-based System - Link Measurement
20m
laun
chca
ble
20m receivecable
50m
50m
3m 3m10m
- Native MPO link- Use launch and receive cables – 20m typical
Enterprise-SLM verifies the integrity of the link and ensures properinstallation of MPO fiber sections and individual connections
48
CERTiFi
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 49
CERTiFi is a cloud-based solution for teams who design, build, test, and certify the structured cabling in enterprise networks. Powered by the Viavi Solutions StrataSync™ platform, CERTiFi empowers every team
member with the information needed to complete tasks accurately and on time.
With CERTiFi, team members establish alignment at every stage of their project - from creating design requirements and assigning tasks, to performing tests and analyzing project metrics in real-time. Manage
your projects with confidence and equip your team to succeed with CERTiFi.
Certification represents completion of project when building Enterprise networksIt is what the contractor provides their customer as a record of their work
The name CERTiFi reinforces Viavi’s ability to help customers achieve their objectives
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 50
• Manage projects with confidence at every stage• Align your team and project requirements in one place• Increase team workflow with cloud connectivity• Track project status and analyze results from anywhere• Enhance your test tools for greater productivity• Generate detailed certification reports
What can CERTiFi do for me?
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 51
Design Projects with Online UI
Assign Tasks Directly to Team Members
Upload Test Parameters Directly to Test Devices
Deploy Tasks to Instruments with the CERTiFi Mobile App
Generate Certification Reports
Analyze Real-Time Metrics
Access Information from Anywhere
Test to Configured Design Requirements
Manage projects with confidence at every stage
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 52
▪Web-based interface allows login accessfrom anywhere▪Design and manage multiple projects▪Create templates for labeling▪Organize test hierarchies▪Add attachments
▫ Drawings, maps, photos▫ Scope of work docs▫ Import from AutoCAD and other sources
▪Use test profiles to manage acceptancecriteria▪Use pre-populated vendor specs or
customize your own requirements
Design
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 53
Design Assign
▪ Assign projects to other team members▫ Project Managers▫ Field technicians
▪ Technician receives assignmentnotifications on their mobile device
▫ Uses the CERTiFi Mobile App▫ Available for both iOS and Android
▪ CERTiFi mobile allows users to:▫ View test requirements▫ View label configurations▫ View attached files▫ Deploy specific tests to field instruments via
WiFi (iOS) or Bluetooth (Android)
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 54
▪ Instruments with deployed tasks have alltest criteria onboard:▫ Label lists▫ Acceptance Criteria▫ Notes
▪Technician performs the connectivityrequired for reference and for test
▪Enrich test data with notes, pictures, andvideos
▪Results automatically sync to cloud throughthe mobile device that deployed the task
Design Assign Test
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 55
▪Site leads can view project status and testresults on mobile device
▪Project designer can view progress fromthe web interface:▫ Project dashboards▫ Test results
▪Provide real time feedback to fieldtechnicians throughout the project
Design Assign Test Analyze
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 56
Product Solution Description
Web Interface
Mobile App
Instruments
Cable sets pushed to mobile app(label and instrument configuration)
• Create projects• Create “cable sets (tasks)” by associating “label lists” with “test profiles”
• Create “label lists”• Create “test profiles”
• Assign “Cable sets” to project team membersProject Manager
Technician • Connect to system under test – perform any and all connectivity required – for reference and for test
• Notification of activity assignment(s)• Instrument(s) required to perform task
• Push configuration from cloud to instrument
• View progress dashboards• Store results if off-line• Enrich data with notes, pictures, videos• Upload results to cloud (automatic)
• Progress dashboards,test reports, test results
Existing instruments – connected to Mobile App via low configuration wireless
Certifier OLTS-85 MTS/TB-2000 Future
Project Manager,
One of our unique solutions
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 58
ONMSi: Fiber Monitoring Solutions
Monitored Fiber
XCable cut
Optical Fault
Location sent to the
Customer by Email or SNMP
Automatic and Accurate Fault location in a few minutes
instead of hours
59
SLA Validation using the MTS-5800
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 60
Four Market Segments for Metro
Transport & Central Office Business
Services
Data CenterMobility
Long Haul and Metro networks
Install & troubleshooting services to businesses
Install & maint. of mobile backhaul & fronthaul
DC interconnect & maintenance
Business Drivers• Add more metro capacity to
support video, mobile, and cloudservices
Pain Points• Dealing with new line rates• Determining if optics and cables
are capable of supporting 100G+services
Business Drivers• Reduced time to revenue• Decrease downtimePain Points• Lack of test gear & tech knowledge
for new service offerings• Slow SP mentality in a speedy cloud
world
Business Drivers• More capacity and more coveragePain Points• Many different things to test: fiber,
OTDR, CPRI, PTP, timing• Not able to test timing and sync
which will make LTE-A/5G fail
Business Drivers• Need to back up data center quickly
and retrieve data quicklyPain Points• Taking hand-off from SPs and
cross-connecting to customers• Qualification of optics and cabling• Measuring intra-DC BER
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 61
Viavi Recommended Best Practice Workflows
Multiple Class of Service (COS) Workflow
RFC 6349 TrueSpeedLayer 4 TCP Throughput
J-ProofLayer 2 Control Plane
Transparency Test:
Y.1564 SAMCompleteEthernet KPI for Multiple
ServicesOR
RFC 2544 for single stream
QuickCheckBasic Connectivity Test
Ethernet layer workflows
Enhanced RFC 2544
QuickCheck SAMComplete TrueSpeed
Optics Self-TestOTN Check
PTP Check
Sell our workflows: Consistency across protocols, simplicity
OTN activation workflow
PTP 1588 Time Error testworkflow
Pluggable Optics Test workflow
CPRI Transport Test workflow CPRI Check
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 62
Reduce OpEx with Ethernet Service Activation Testing
TrueSAM
RFC-6349TrueSpeed
Validates TCP Throughput and User Experience
J-ProofValidates Layer 2 Control plane Transparency – CDP, SDP, etc.
RFC-2544Validates KPI for single stream
No control-plane or user experience validation
Not Testing Ethernet orTesting with L1 or Ethernet BERT
No way to validate KPI or auto-negotiation settings
Testing with Just a Ping
No way to validate KPI or auto-negotiation settings
Y.1564 SAMCompeteValidates KPI for multiple Class of
Service (COS) applicationsNo CP or user experience validation
Virtualized functionality reduces OpEx even more!
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 63
OPERATIONAL EFFICIENCY
ETHERNET SERVICE ACTIVATION
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 64
MARKET TRENDS – CHALLENGES WE SEE TODAY
Increasing Service Differentiation and Application Awareness• Structured with multi-Virtual-links• Many requirements to test above layer 2/3: data throughput, VOIP, Video
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 65
TESTING THE ETHERNET SERVICES
4
321
765
IP
Ethernet
HTTP, FTP, E-mail, Sharepoint, Communicator, Facebook, YouTube, etc
Customer Experience Throughput
TCP RFC 6349 TrueSpeedTM
Network ThroughputY.1564
& RFC 2544
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 66
DIFFERENTIATED SERVICES NEED DIFFERENTIATED TESTING
Enhanced RFC-2544 with
J-Quickcheck
Y.1564SamComplete™
RFC-6349TrueSpeed™
Experience your Network Like your Customer Does
Prove KPIs for differentiated services like VoIP, Video, Data
Verify basic performance characteristics
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 67
• Save time by automating the first fewsteps of the M&P
• Available as a standalone test or…• Integrated into both RFC-2544 and
Y.1564 tests• One screen test setup determines:
– Correct auto-negotiation settings– Connectivity and loopback with the far end– Performs a quick throughput test
QUICKCHECKSAVE TEST TIME IF A MAJOR CONFIGURATION PROBLEMEXISTS
RFC-6349TrueSpeed
Layer 4 TCP Throughput
Enhanced RFC-2544
Y.1564SAMComplete
QuickCheck Basic
Connectivity Test
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 68
• The industry standard serviceactivation test for Ethernet andIP services
• Measure Key PerformanceIndicators and Bandwidth Profile– Throughput– Latency– Packet Jitter– Frame Loss– Committed Burst Size - CBS
• Fully automated with reportgeneration
ENHANCED RFC-2544CUTS TEST TIME IN HALF
RFC-6349TrueSpeed
Layer 4 TCP Throughput
Enhanced RFC-2544
Ethernet KPI Verification
Y.1564SAMComplete
QuickCheck Basic
Connectivity Test
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 69
• Multiple service Ethernet and IPservice activation test
• Measure Key PerformanceIndicators and Bandwidth Profile– CIR, EIR (Throughput)– Frame Delay – FD (Latency)– Frame Delay Variation – FDV (Jitter)– Frame Loss Rate - FLR– Committed Burst Size – CBS– Policing
• Fully automated with reportgeneration
Y.1564 SAMCOMPLETEACHIEVES 33% REDUCTION IN TEST TIME
RFC-6349TrueSpeed
Layer 4 TCP Throughput
Enhanced RFC-2544
Y.1564SAMComplete
QuickCheck Basic
Connectivity Test
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 70
RFC-2544 Y.1564 SAMComplete
Main Application Turn up new backbone link or end-to-end connection
Turn up new Ethernet router connection(s) with per service
KPIs - Parameters Measured
Throughput LatencyFrame Loss RateBurstabilityViavi Extra: Packet Jitter Viavi Extra: CBS
Throughput – CIR/EIR Latency – Frame Delay (FD) Frame Loss Rate (FLR)Packet Jitter – Frame Delay Variation (FDV)Burstability – CBS
Key Focus One stream (address pair) maximum transport performance
Multiple streams (address pairs) tests policers and shapers on router/switch
CBS: Committed Burst SizeKPI: Key Performance Indicators
CIR: Committed Information Rate EIR: Excess Information Rate
RFC-2544 & Y.1564 COMPARISON
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 71
▪ Prequalify customer quality of experience (QoE)▪ Standardized TCP throughput test▪ Repeatable test to measure:
– Application throughput (usingTCP)– MTU size– Round trip delay/time (RTT)– Optimal TCP window size– TCP Efficiency– Buffer Delay
RFC-6349 TRUESPEEDELIMINATE FINGER POINTING WITH A REPEATABLE TCPTEST
RFC-6349TrueSpeed
Layer 4 TCP Throughput
Enhanced RFC-2544
Y.1564SAMComplete
QuickCheckBasic ConnectivityTest
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 72
WHICH RESULT WILL YOU GET?
RFC-2544
Jitter
Latency
Burst Tolerance
Throughput
Frame Loss
Y.1564
SaaS
TCP EfficiencyBuffer DelayTCP Window size Optimization Policing/Shaping
RFC-6349
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 73
1) Service Activation / Turn-Up– Verify service meets SLA at L2/L3 with RFC-2544 or Y.1564– Verify optimal TCP Performance– Keep records for future comparison
2) In-Service Troubleshooting– Customer calls complaining of poor throughput– Dispatch field engineers with TCP Truespeed-enabled testers to fault find and to fix– OR activate a virtual test function and begin testing without anyone going
anywhere!
WHEN TO DO TCP/TRUESPEED ?
74
PRODUCT PORTFOLIO : RAMPING UP 1G SERVICES ANDBEYOND…
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 75
SMARTCLASS-4800 COVERS THE NEEDS
SC 4800 Mainframe▪ Can be programmed with different SW Test
Options that enhance the functionality of the instrument
▪ Two versions▪ Ethernet up to 1GE Only▪ Ethernet up to 1GE + T1/E1 (Includes
ISDN PRA)
P5000iFiber Microscope
MP-60/80Power Meter
Viavi Manufactured Accessories
Viavi Purchased AccessoriesTo our Spec
SW Test OptionsApplied directly on Mainframe
RFC 2544
QuickCheck Y.1564
TrueSpeed PTP Check
Automated Test Suites
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 76
TWO MODEL : SC-4800 ANDSC-4800P
100M & 1G Optical Ethernet
10/100/1000MElectrical Ethernet
T1 & E1
100M & 1G Optical Ethernet
10/100/1000MElectrical Ethernet
SC-48001GE only
SC-4800P1GE + E1/T1
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 77
SMARTCLASS-4800 CAPABILITIES OVERVIEW
4 Packages :• SC4800-GIGE-NOPT includes GE, multiple streams, IPv4
• SC4800-GIGE includes GE, multiple streams, IPv4 with 1310nm Optic
• SC4800P-GIGE-T1/E1-NOPT includes GE, multiple streams, IPv4, T1/E1
• SC4800P-GIGE-T1/E1 includes GE, multiple streams, IPv4, T1/E1 with 1310nm Optic
Ethernet Line Rate Interfaces includes :• Layer 2 and Layer 3 Loopback• Line Rate Traffic Generation of Layer 2 or Layer 3 (IPv4) traffic• Analysis of key performance indicators (KPIs):
• Throughput/Committed Information Rate• Frame Loss• Round Trip Delay• Jitter• Committed Burst Size
• Automated test suites for Ethernet activation:• QuickCheck, RFC-2544 and Y.1564• Multiple Stream traffic generation• Ping and Traceroute test applications17
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 78
Multi touch screen For AdvancedControl of 5800v2
Test Interface PanelExternal Devices2 x USB1 x RJ4510/100/10001PPS2.5mm Headset JackPower Connector
Web Browser
3G/LTE Data via dongle
MTS-5800V2OVERVIEW – ‘MAINFRAME’
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 79
T-BERD/MTS 5800v2 Platform – Always 10G-ready – 3 Versions
Single Port Mainframe(5811P)
Dual Port Mainframe(5822P)
Supported Line Rates:
• DSx/PDH - E1, DS1, E3, DS3, E4, STS-1,STM-1e
• 10/100/1000Base-T Ethernet
• 1GE & 10GE Ethernet LAN/WAN
• SONET/SDH - STM-1-64 & OC3-192
• Fibre Channel - 1,2,4,8,10,16G FC
• CPRI/OBSAI 614M – 10.1G
• OTN - OTU1/2/1e/2e (Dual Port required),ODU0, ODU Mux, ODU Flex
• High Accuracy Timing applications Dual Port Mainframe(5882)
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 80
Enhanced Cable Diagnostics – Testing Shielded Ethernet Outdoors
▪ TB/MTS 5800-EPP – Ethernet Peering Partner – is used on the far end tocomplete shield ground & wiremap test
▪ TB/MTS 5800-EPP (Ethernet Peering Partner) is a layer 1 traffic reflector▫ Supports reflecting RFC 2544, Y.1564 or QuickCheck Tests over the cable
▪ All cable diagnostic test results are integrated with Job Manager
3 main test
1. Cable Length – is the cable under 100 meters2. Cable Wiremap – are pin-outs correct3. Shield ground continuity test – did I crimp it
down correctly?
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 81
Enhanced Cable Diagnostics – Indoor Applications
F1
F2
F3
▪ Troubleshoot cable length
▪ Troubleshoot wiremap problems including polarity and skew
▪ Run QuickCheck, RFC 2544 or Y.1564 BERT tests to troubleshoot and validate L1 10/100/1000 performance
▪ Full TB/MTS test set Features include RFC 6349 (TCP), Top Talk Analysis, VoIP, etc.
SC 4800Or
Any 5800TB/MTS5800-EPP
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 82
THE MTS-5800-100G: A COMPLETE SOLUTION
Complete solution for:– All rate testing 1.5M/2M to 112G– Dual ports up to 112Gb/s– Concurrent Protocol/BERT & Fiber Optics– High-accuracy sync & timing measurements
MTS-5800-100G
It reduces installation and troubleshooting time:• Fast service activation tools• 2 concurrent BERT tests up to 100G• 5 concurrent tests including FO, power Meter, fiber scope
ROI & investment protection by:• Providing flexible HW (FPGA) which supports 100GE/40GE, 32GFC, 25GE
and 10G CPRI and then 24G CPRI (to come)• Providing module expansion (OTDRs, TEM, OSA)
Areas – where it is used1. Operator Service Activation2. Troubleshooting3. NEMS Installation Teams4. Data Center Interconnect5. Internet Content Providers6. Labs and factories
82
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 83
THE MTS-5800-100G OVERVIEW: HARDWARE
QSFP+/28SFP+/28 CFP4RJ45
RJ48c
MiniBNC
GPSAntenna
Clk In/Out
1 PPSRef In
Ext Clk In
Timing Connectors
Clk In/Out (1PPS in/Out) OWD In Ref PTP In Ref 2MHz In DUT10MHz In DUT1PPS In DUT
1PPS In 1PPS In Ref
Ext Clk T1/E1 Ref In 2MHz Ref In 10MHz Ref In SyncE Ref In
Only 1 HW variant, always upgradable
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 84
GPSAntenna (OWD)
Clk In/Out(OWD In Ref, PTP In Ref, 2MHz In DUT,10MHz In DUT,1PPS In DUT)
1 PPSRef In
Ext Clk In (T1/E1, 2/10MHz,SyncE)
2x QSFP28 / QSFP+ 100GE / 40GE OTU4 / OTU3
1x CFP4100GE/OTU4
2x SFP28/ SFP+
RJ45 10/100/1000(use copper SFP on port 1)
RJ48c T1/E1
Mini-BNC T3/STS-1e E3/E4
2x SFP+/SFP281-10G Ethernet LAN/WAN/BaseT 25GE OTN 1-1e/2e/2STM-1-64 & OC3-192Fibre Channel: 1,2,4,8,10,16G, 32G FCCPRI 614M – 10.1G (24G to come)
MTS-5800-100G PLATFORM :MULTIPLE INDEPENDENT CONCURRENTAPPLICATIONS
One variant : Always upgradable to dual-port
– Dual ports up to 112Gb/s• Dual 100GE including RS-FEC, Dual OTU4 bulk• Dual 25GE and 32GFC• Dual any rate, any combination
– Concurrent Protocol/BERT & Fiber Optics
MTS 5800-100GDual-port view
Enhanced RFC 2544
QuickCheck SAMComplete
TrueSpeedOptics Self-Test
OTN Check
PTP Check
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 85
BACKGROUND: 100GE OPTICS = QSFP-28 /CFP4
Client optics• Smaller optics are a 100G network enabler: lower power, lower cost and higher density• QSFP28 provides smallest size & lower cost potential
CFP
CFP4CFP2
NowLR4
LR4 & SR10SR10
CXP
QSFP28
10G I/O
10 physicalelectrical lanes CFP
CFP2
4 physical electrical lanes
25G I/Oor
10G I/O
4 physical electrical lanes
25G I/OQSFP28
CFP4
MTS-5800-100G supports both QSFP28 & CFP4
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 86
Interface Reach Medium Parallelism Standard RS-FEC
100GBASE-ER4 40 km SMF 4 λ / dir IEEE 802.3ba NoER4-Lite 20-25km SMF 4 λ / dir Variation on
802.3baPotentially
100GBASE-LR4 10 km SMF 4 λ / dir IEEE 802.3ba NoCWDM4 2 km SMF 4 λ / dir CWDM4 MSA YesCLR4 2 km SMF 4 λ / dir CLR4 Alliance OptionalPSM4 500 m SMF 4 fibers / dir PSM4 MSA YesSWDM4 100 m MMF 4 λ / dir SWDMAlliance Yes100GBASE-SR4 70 m
100 mOM3 MMF OM4 MMF
4 fibers / dir IEEE 802.3bj Yes
100GBASE-SR10 100 m125 m
OM3 MMF OM4 MMF
10 fibers / dir 802.3ba No
MTS-5800-100G supports the newer interfaces using RS-FEC
5800-100G
CSAM
BACKGROUND: 100GE CLIENT INTERFACES
© 2018 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information 87
▪ 1U rackmount system with dual ports up to 100G▪ GUI and automation interface shared with the T-BERD/MTS 5800-100G
MAP-2100 Main Attributes
FeaturesAvailable with AC power; DC (-48V Dual) version plannedLCD display for IP address and boot progressManagement RJ-45 access via front or optionally backServiceable fan trayOptional optical switch 1x4 LC DUAL (SW support on roadmap)System access via VNC (encryption available) and SCPI automationOption for secure environment access through port 22 only, encryption support