DOC-3012-01Document Revision 01.00.02
February 2012
C1G CMTS
Hardware Installation Guide
© 2012 Casa Systems, Inc.All rights reserved. Licensed software products are owned by Casa Systems or its suppliers and are protected by United States copyright laws and international treaty provisions.
The information regarding the product in this manual is subject to change without notice. All statements, information, and recommendations in this manual are believed to be accurate but are presented without warranty of any kind, express of implied. Users must take full responsibility for their application of the product.
In no event shall Casa or its suppliers be liable for any indirect, special, consequential, or incidental damages, including, without limitation, lost profits or loss or damage to data arising out of the use or inability to use this manual, even if Casa or its suppliers have been advised of the possibility of such damages.
Safety and Regulatory Agency Compliance
The C1G complies with the safety and regulatory agency standards listed below when installed in accordance with this guide.
Product Safety
Representative samples of this product have been evaluated by a Nationally Recognized Test Laboratory (NRTL) and meet the applicable U.S., Canadian, and International safety standards:
• ANSI/UL 60950-1 - UL Standard for Safety for Information Technology Equipment Safety.
• EN/UL/IEC/CAN/CSA C22.2 No. 60950-1 - Standard for Safety for Information Technology Equipment Safety.
• EN60950-1
Grounding
The C1G is grounded from the DC power module to the chassis and through the ground (GND) wire in the AC power cord that connects to the DC module. There is no separate grounding connection.
EMC
The C1G has been tested and meets the following requirements:
• EN-55022, Class A
• EN-55024
• FCC Part 15 Class A, CISPR Class A
Electrical HazardBefore powering up the DC-powered C1G, make sure the earth ground terminal on the power module is connected to the Protective Earth (PE) of the building.
FCC Declaration of Conformity
We declare under our sole responsibility that:
Product Name: C1G
To which this declaration relates, is in conformity with the following standards or other documents:
• ANSI C63.5-1992 Methods of Measurement
• Federal Communications Commission 47 CFR Part 15, Subpart B
• 15.107 (b) Class A Conducted Limits
• 15.109 (b) Class A Radiated Emission Limits
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by Casa Systems, Inc. may void the users’ authority to use this equipment.
CE Declaration of Conformity
Equipment: C1G
Name and address of applicant:
Casa Systems, Inc.100 Old River RoadSuite 110Andover, MA 01810USA
Name and address of manufacturer:
Casa Systems, Inc.100 Old River RoadSuite 110Andover, MA 01810USA
Rating and principal characteristics:
AC: 5A, 100-240V~, 60/50Hz
DC: -48VDC (X2), 9A
Model / Type Ref.: C1G
As sample of the product has been tested and found to be in conformity with the:
73/23/EEC (Low Voltage, 89/336/EEC (EMC) Directives
Standards used:
EN60950-1
FCC Part 15, Subpart B, Class A
EN55022, Class A Conducted Emissions
EN55022, Class A Radiated Emissions
EN55024
EN-61000-3-2, Harmonics
EN-61000-3-3, Flicker
EN-61000-4-2, ESD
EN-61000-4-3, Radiated Susceptibility
EN-61000-4-4, Electronic Fast Transients
EN-61000-4-5, Surge
EN-61000-4-6, Conducted RF Susceptibility
EN-61000-4-11, Voltage Dips and Interruptions
We, herewith declare,
Casa Systems, Inc.100 Old River RoadSuite 110Andover, MA 01810USA
That the above listed product complies with the appropriate basic safety and health requirements of the EC Directive based on its design and type, as brought into circulation by us. In case of alteration of the product, not agreed upon by us, this declaration will lose its validity.
Date/Authorized Signature ____________________________________________
Title of Signatory ___________________________________________________
Company: Casa Systems, Inc.
Year CE mark first applied: 2012
vii
Contents
Safety and Regulatory Agency ComplianceProduct SafetyGroundingEMCFCC Declaration of ConformityCE Declaration of Conformity
Preface
About this guide ................................................................................................... viiRevision history.............................................................................................. vii
Safety information and symbols...........................................................................viiiContacting Casa ................................................................................................... ix
Corporate facility ............................................................................................. ixTechnical Support ........................................................................................... ixTechnical documentation ................................................................................ ix
Conventions used in Casa documentation ............................................................ xTypographical conventions .............................................................................. xAcronyms ........................................................................................................ xi
Chapter 1. Casa C1G hardware overview
About this chapter ............................................................................................. 1-1.
C1G system overview ....................................................................................... 1-1.
Network capabilities .................................................................................... 1-2.
C1G chassis ...................................................................................................... 1-2.
Front and rear views ................................................................................... 1-2.
Figure 1-1.Casa C1G CMTS front view ................................................ 1-3Figure 1-2.Casa C1G CMTS rear view.................................................. 1-3
C1G system components .................................................................................. 1-4.
Casa Systems C1G CMTS
ContentsHardware Installation Guideviii
Table 1-1. C1G components ................................................................. 1-4DC power supplies ...................................................................................... 1-5.
Figure 1-3.C1G AC power connectors and cables ............................... 1-5Integrated fan assemblies ........................................................................... 1-6.
Console and network interfaces .................................................................. 1-6.
DOCSIS MAC interface .............................................................................. 1-6.
System status LEDs .......................................................................................... 1-7.
Table 1-2. C1G LED indications ............................................................ 1-7
Chapter 2. Installing the C1G hardware
About this chapter ............................................................................................. 2-1.
Safety guidelines for C1G installation ............................................................... 2-1.
Electrical equipment guidelines .................................................................. 2-2.
Required tools ................................................................................................... 2-2.
Unpacking the system ....................................................................................... 2-2.
Shipping contents ....................................................................................... 2-3.
Installing the system in a rack ........................................................................... 2-3.
System ventilation at the installation site .................................................... 2-3.
Installation procedure .................................................................................. 2-3.
Figure 2-1.Installing rack mounting hardware and power module support . ............................................................................................2-5Figure 2-2.C1G system with rack mounting kit ..................................... 2-6Figure 2-3.Sample C1G CMTS rack installation.................................... 2-6
Installing the optional wall mount ...................................................................... 2-7.
Figure 2-4.C1G wall mount bracket installation ..................................... 2-7Using the standalone dual power module pocket ............................................. 2-8.
Figure 2-5.Standalone dual power module pocket assembly ................ 2-8
Chapter 3. Connecting and starting the C1G
Connecting the Gigabit Ethernet ports .............................................................. 3-2.
Installing SFP modules ............................................................................... 3-2.
Figure 3-1.Sample SFP module ............................................................ 3-2Connecting Ethernet to the SFP ................................................................. 3-3.
Casa Systems C1G CMTS
ContentsHardware Installation Guide ix
Figure 3-2.Connecting Gigabit Ethernet ports....................................... 3-3Removing Ethernet cables and the SFP module .........................................3-4.
Connecting to the console port ..........................................................................3-4.
Figure 3-3..RS-232 pinouts on console port.......................................... 3-5Figure 3-4.C1G console port connections............................................. 3-6
Connecting the RF I/O ports ..............................................................................3-7.
Figure 3-5.Connecting the upstream and downstream ports. ............... 3-7Connecting the DC power modules ...................................................................3-8.
Figure 3-6.Connecting redundant DC power ........................................ 3-9Starting the C1G CMTS ...................................................................................3-10.
Table 3-1. C1G LED indications.......................................................... 3-10
Appendix A. C1G hardware specifications
Physical, electrical, and environmental ........................................................... A-2.
Table A-1. C1G CMTS specifications.................................................... A-2Safety and regulatory compliance .................................................................... A-3.
Product safety ............................................................................................. A-3.
Grounding ................................................................................................... A-3.
EMC ............................................................................................................ A-3.
Immunity ......... ............................................................................................ A-3.
Chassis components and capacities ................................................................ A-4.
Table A-2. C1G capacities..................................................................... A-4DOCSIS QAM interface specifications ............................................................. A-5.
Table A-3. DOCIS QAM specifications.................................................. A-5DOCSIS upstream interface specifications ...................................................... A-6.
Table A-4. C1G DOCSIS upstream specifications ................................ A-6C1G component ordering ................................................................................ A-6.
Table A-5. C1G components ................................................................. A-6
Casa Systems C1G CMTS
vii
Preface
About this guide
The Casa Systems – C1G CMTS Hardware Installation Guide covers the initial hardware installation for the Casa C1G CMTS. This guide is intended for system administrators, engineers, and operators who are responsible for installing and managing the C1G. Users who perform these tasks should also be familiar with power and protective earth (PE) cabling, electronic circuitry, wiring practices, and safety precautions.
For information on configuring the CMTS software running on the C1G, refer to the Casa Systems – CMTS Software Configuration Guide and the Casa Systems – CMTS Network Solutions Guide.
The following topics are covered in this guide:
Revision history
• 01.00.02 — New issue of the Casa Systems – C1G CMTS Hardware Installation Guide.
For information about See
C1G CMTS hardware Chapter 1.
Installing the C1G Chapter 2.
Connecting the hardware Chapter 3.
Technical specifications Appendix A.
Casa Systems C1G CMTS
PrefaceHardware Installation Guideviii
Safety information and symbols
The following symbols that appear in this guide. Before working on equipment, be aware of the hazards involved with electrical circuitry and standard safety practices that can help prevent accidents.
Warning: This symbol means the task may present an electrical hazard that could cause bodily injury. Before you work on any equipment, you must be aware of the hazards involved with electrical circuitry, and familiarize yourself with standard practices for preventing accidents.
Caution: This symbol means that you must be careful. In this situation, performing tasks incorrectly could result in equipment damage or loss of data.
Danger: This symbol means that a task may present physical danger associated with lifting and moving physical equipment. This includes bodily injury and damage to system hardware.
Note: This symbol provides important or supplemental information about a task that you are performing.
Casa Systems C1G CMTS
PrefaceHardware Installation Guide ix
Contacting Casa
Corporate facilityCasa Systems, Inc.100 Old River RoadAndover, MA 01810Tel.: 978-688-6706World Wide Web: www.casa-systems.com
Technical SupportIn the United States: Tel: 978-699-3045E-mail: support@casa-systems.com
Technical documentationCasa Systems provides the following documentation set in PDF format, viewable using Adobe Reader 5.0 or later. These PDF files are available from the Casa FTP site at ftp://support.casa-systems.com.
• Casa Systems – C2200 CMTS Quick Installation
• Casa Systems – C2200 CMTS Hardware Installation Guide
• Casa Systems – C3200 CMTS Quick Installation
• Casa Systems – C3200 CMTS Hardware Installation Guide
• Casa Systems – C1G CMTS Quick Installation
• Casa Systems – C1G CMTS Hardware Installation Guide
• Casa Systems – C10G/C10200 CMTS Quick Installation
• Casa Systems – C10G CMTS Hardware Installation Guide
• Casa Systems – C10200 CMTS Hardware Installation Guide
• Casa Systems – CMTS Software Configuration Guide
• Casa Systems – CMTS Network Solutions Guide
• Casa Systems – CMTS Debugging and Diagnostics Reference
• Casa Systems – CMTS Release Notes
Casa Systems C1G CMTS
PrefaceHardware Installation Guidex
• Casa Systems – C1G CMTS Release Notes
Conventions used in Casa documentation
Typographical conventions
Note: Casa Systems provides updates to the manuals on a regular basis. Log on to the Casa FTP site for the latest files in PDF format.
Key Convention Function Example
Boldface font Commands and keywords are in boldface.
Type abc, then press [ENTER]
Italic font Arguments for which you supply values are in italics.
number
brackets [ ] Elements in square brackets are optional.
[portNumber]
braces {x | y | z} Indicates a required argument with a choice of values; choose one.
{enabled | disabled}
brackets [x | y | z] Indicates an optional argument with a choice of values; choose one.
[abc | 123]
vertical bar | Separates parameter values. Same as “or.”
{TCP | TLS}
String A non-quoted set of characters. Do not use quotation marks (“”)around the string as the string will include the quotation marks.
abc
Screen font CLI sessions and information the system displays are in screen font.
Boldface screen font Information you must enter is in boldface screen font.
Italic screen font Arguments for which you supply values are in italic screen font.
number
Casa Systems C1G CMTS
PrefaceHardware Installation Guide xi
Acronyms
Casa Systems manuals contain the following industry-standard and product-specific acronyms:
AAA Authentication, Authorization, AccountingARP Address Resolution ProtocolCMTS Cable Modem Termination SystemDBC Dynamic Bonding ChangeDCU DOCSIS Control and UpstreamDDM DOCSIS Data ManagerDOCSIS Data Over Cable Service Interface SpecificationDHCP Dynamic Host Configuration ProtocolDQM DOCSIS QAM moduleGigE Gigabit EthernetHFC Hybrid fiber coaxialICMP Internet Control Message ProtocolIP Internet ProtocolMIB Management Information BaseNTP Network Time ProtocolPCMM Packet cable multimedia
^ The symbol ^ represents the key labeled CTRL (control). The key combination ^D in a screen display means hold down the CTRL key while pressing the D-key.
< > Non-printing characters such as passwords are in angle brackets in contexts where italics are not available. Angle brackets are also used for variables.
!,# An exclamation point (!) or a pound sign (#) at the beginning of a line of code indicates a comment line.
# This is a comment.
Key Convention Function Example
Casa Systems C1G CMTS
PrefaceHardware Installation Guidexii
PIM Protocol Independent MulticastQAM Quadrature Amplitude ModulationSNR Signal to Noise RatioSTB Set Top BoxTCP Transmission Control ProtocolTOS Type of serviceUCC Upstream channel changeUPS Uninterruptable power supplyURL Uniform resource locatorVoIP Voice over IPVLAN Virtual local area network
Casa Systems C1G CMTS
1-1
Chapter 1. Casa C1G hardwareoverview
About this chapterThis chapter describes the Casa C1G CMTS hardware and components.
C1G system overviewThe Casa Systems C1G Cable Modem Termination System CMTS) is a new class of cable edge device that combines a third generation DOCSIS CMTS and IPTVdevice that allows cable operators to deliver digital video services over an economical and compact platform. Cable ISPs can remotely deploy the C1G in distributed locations (such as apartment towers) with Layer-2 switching capability on top of DOCSIS 3.0 to provide data and IPTV services.
Topic Page
C1G system overview 1-1
Network capabilities 1-2
C1G chassis 1-2
Front and rear views 1-2
C1G system components 1-4
DC power supplies 1-5
Integrated fan assemblies 1-6
Console and network interfaces 1-6
DOCSIS MAC interface 1-6
System status LEDs 1-7
Casa Systems C1G CMTS
C1G chassisHardware Installation Guide1-2
Network capabilitiesThe C1G consists of a base system with one DOCSIS MAC interface consisting of one downstream DQM QAM and up to two upstream DCU interfaces.
The single DOCSIS QAM interface provides DOCSIS packet processing and QoS, DOCSIS downstream MAC, PHY, and RF up-conversion over 8 channels using one physical output port. The single DOCSIS Control and Upstream (DCU) interface includes DOCSIS packet processing, DOCSIS upstream MAC, and burst mode receivers over 4 channels per each physical port (2).
A standard configuration for channel bonded deployment can be utilizing both upstream channels and the single downstream channel, 8DSx8US for a 1:1 channel ratio for up to 400 Mbps downstream bandwidth in Annex A.
For complete information on the C1G features and capabilities, see the Casa Systems C1G CMTS Data Sheet.
C1G chassisThe C1G chassis is a 1RU enclosure that can be positioned on any flat surface or installed in a standard 19-inch equipment rack in an AC power environment. Rack mounting hardware components are included with the chassis to facilitate mounting in the many rack variations available today.
Front and rear viewsThe C1G front enclosure supports dual AC power inputs, status and alarm LEDs, three internal cooling fans, rack mount points on the chassis sheet metal, integrated console RS-232 RJ45 serial port, 10/100/1000 Ethernet auto-negotiation port, and one GigE copper or fiber SFP port, as illustrated in Figure 1-1 and Figure 1-2.
Casa Systems C1G CMTS
C1G chassisCasa C1G hardware overview 1-3
Figure 1-1. Casa C1G CMTS front view
The C1G rear enclosure provides access to the GigE network interfaces, DQM QAM downstream interface (DS) with F-connector, and two DCU upstream interfaces (US) with F-connectors, as illustrated in Figure 1-2.
Figure 1-2. Casa C1G CMTS rear view
RS-232 local console port(RJ45) AC power input
plugs (A, B)
Power ON/OFF switch
Alarm and Status LEDs
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
System cooling fans (3)
CASA
DQM QAMdownstreamRF output
DCU upstreamRF burst receiver inputs GigE 0
DS US0 US1G0
Copper orfiber SFP
GigE 1
G1
Casa Systems C1G CMTS
C1G system componentsHardware Installation Guide1-4
C1G system componentsTable 1-1 lists the C1G components and order numbers.
Table 1-1. C1G components
Component Order number
C1G DC-powered chassis with integrated fan assembly and DC power modules (2)
C1G-CHASSIS-SFP-SFP
C1G DC power module (2 required for power redundancy (AC power cord is country specific.)
C1G-POWER-MODULE-<country>
Pluggable devices
GigE Small Form Factor Pluggable (SFP) (RJ-45 socket, copper)
SFP-CP
GigE Small Form Factor Pluggable (SFP) (LC socket, fiber optic)
SFP-LC
Caution: Casa C1G is provided in sealed chassis. All C1G-related maintenance is to be performed ONLY by Casa-trained personnel. DO NOT open the unit, as this will void the product warranty and possible service agreements.
Please contact Casa Technical Support for more information.
Casa Systems C1G CMTS
C1G system componentsCasa C1G hardware overview 1-5
DC power suppliesThe C1G ships with a dual DC power module, as illustrated in Figure 1-3. Each DC power module converts 110 to 240VAC to the chassis using the appropriate country cords. Two DC power modules are necessary for C1G power redundancy.
Figure 1-3. C1G AC power connectors and cables
AC power inputplugs (A, B)
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
AC power cords
Removable power plug to AC power source(country cord specific)
Casa Systems C1G CMTS
C1G system componentsHardware Installation Guide1-6
Integrated fan assemblies Three integrated fan assemblies provide cooling air to the chassis from the front of the system where the air is directed across the internal components. The air exits through openings at the rear of the chassis.
Console and network interfacesC1G network interfaces (Figure 1-1 and Figure 1-2) provide Layer 3 packet routing and forwarding as well as system management functionality using the following components:
• Up to two GigE (G0 and G1) ports to accept and transmit video streams in the form of MPEG2 transport streams from a video-on-demand (VoD) server or from IP networks. The port uses an industry-standard small form-factor pluggable (SFP) module for either fiber or copper interface cabling.
• RS-232 local console serial I/O port (RJ45 connector)
DOCSIS MAC interfaceThe DOCSIS QAM interface (DQM) supports DOCSIS packet processing, QoS, DOCSIS downstream MAC, PHY, and RF up conversion, serving as the RF downstream interface between the cable headend and DOCSIS-based cable modems. The DQM interface is a single interface that supports 8 QAM channels.
The DOCSIS Control & Upstream (DCU) interface supports RF burst receiving, signal demodulation, DOCSIS upstream MAC, PHY, as well as packet processing and QoS, serving as the RF upstream interface between the cable headend and DOCSIS-based cable modems. The DCU interface provides two physical upstream ports, with each port supporting 4 channels.
Casa Systems C1G CMTS
System status LEDsCasa C1G hardware overview 1-7
System status LEDsStatus LEDs are present on the front and back of the system, as follows:
• Front panel system status
• Front panel system alarm
• GigE interfaces — G0 (GigE0) and G1 (GigE1)
Table 1-2. C1G LED indications
Location LED Color Indication
Front panel Status Green System turned on; running normally.
Black (off) No power condition; system off.
Alarm Black Normal operation; no alarms present while system status remains in the green state.
Red Error condition detected.
GigE port G0 and G1
(L)ink status
Green Ethernet link up and connected.
Black (off) Ethernet link down; no connection
(A)ctivity Green Ethernet link is transmitting or receiving data.
Black No network activity currently present on link.
Casa Systems C1G CMTS
2-1
Chapter 2. Installing the C1Ghardware
About this chapterThis chapter covers the C1G CMTS basic installation.
Safety guidelines for C1G installationThis section provides general safety guidelines during equipment installation and operation.
Topic Page
Safety guidelines for C1G installation 2-1
Electrical equipment guidelines 2-2
Required tools 2-2
Unpacking the system 2-2
Shipping contents 2-3
Installing the system in a rack 2-3
System ventilation at the installation site 2-3
Installation procedure 2-3
Installing the optional wall mount 2-7
Using the standalone dual power module pocket 2-8
Warning: Only trained and qualified personnel should install, replace, or service this equipment.
Do not work on the system or connect or disconnect cables during lightning activity.
Casa Systems C1G CMTS
Required toolsHardware Installation Guide2-2
Electrical equipment guidelines
Be sure to follow these important electrical guidelines:
• Always unplug or disconnect the power cable before installing or removing the unit.
• Locate the emergency power-off switch for the room in which you are working. If an electrical accident occurs, turn off the power immediately.
• Do not work alone if potentially hazardous conditions exist.
• Never assume that power is disconnected from a circuit. Always check.
• If an electrical accident occurs, proceed as follows:
— Use caution; do not become a victim yourself.
— Turn off power to the system.
— If possible, send another person to get medical aid. Otherwise, assess the condition of the victim and then call for help.
— Determine whether the person needs rescue breathing or external cardiac compressions; then take appropriate action.
Required toolsThe following tools are necessary for C1G installation:
• #2 Phillips screwdriver for rack mounting hardware
• Level, power drill and bits, and mounting hardware for the optional wall mounting kit and the optional standalone dual power module pocket.
Unpacking the systemWhen the system arrives at your installation site, you will need to carefully unpack the system and other items included with the shipment. Check the shipping box for any exterior damage.
Note: If damage is present, notify the shipping company and Casa Systems immediately for a return material authorization, if necessary.
Casa Systems C1G CMTS
Installing the system in a rackInstalling the C1G hardware 2-3
Shipping contents
The following items are included with the C1G:
• Technical documentation CD-ROM
• Rack mounting hardware (brackets, screws, and power module support mount)
• Console cable for local system management
• DC power modules with AC power cables (as ordered for the destination country)
• Small form-factor pluggable (SFPs) modules for Ethernet connections
Installing the system in a rack The C1G is designed as a free-standing unit, but can be optionally installed in a standard 19-inch mounting rack using Casa-supplied rack mounting hardware with the dual power module support.,
System ventilation at the installation site
When installing equipment, ensure adequate ventilation is available. Inadequate ventilation will result in higher than normal operating temperatures and may result in degraded operation. Always ensure the system receives sufficient airflow such that it will operate within the specified operating temperature range.
Installation procedure
Use the following procedure to install the C1G rack mounting hardware. The hardware kit consists of steel mounting brackets (4), flathead screws (17), and the dual power module support. Installing the dual power module support provides the correct chassis width for installing the C1G in a standard rack.
Caution: Caution must be exercised when rack-mounting this or any other type of equipment. Ensure that all equipment is properly secured using the specified hardware. Equipment must be installed in a safe manner to prevent overloading, tipping over, or other unsafe conditions.
Casa Systems C1G CMTS
Installing the system in a rackHardware Installation Guide2-4
1. Locate the rack mounting hardware kit included in the shipping box.
2. Referring to Figure 2-1 (Step 1), attach the dual power module support bracket to the C1G using three (3) screws. Tighten the screws until snug.
3. Using two (2) screws, attach the appropriate right-angle bracket to the back of the support bracket. See Figure 2-1 (Step 2).
4. Using six (6) screws, attach the dual power module right angle bracket to the left side of the C1G and to the back of the support. See Figure 2-1 (Step 3).
5. Using three (3) screws, attach the support to the left-front right-angle bracket. See Figure 2-1 (Step 4).
6. Using three (3) screws, attach the right-front right-angle bracket directly to the C1G. See Figure 2-1 (Step 5).
7. When ready, lift the system up to the desired height in the rack and secure the system to the rack using four screws.
Note: Each mounting bracket in the kit is unique and each will properly align with their intended mounting points. You will not be able to mismatch any of the brackets during the kit installation.
Note: You must provide the four screws that attach the C1G CMTS to the rack since the requirements for these screws will vary depending on the specifications from the rack manufacturer.
Casa Systems C1G CMTS
Installing the system in a rackInstalling the C1G hardware 2-5
Figure 2-1. Installing rack mounting hardware and power module support
Top viewC1G system
Rack mountingbracket andscrews.
Top viewC1G system
DC powermodule bay
DC powermodule bay
Dual power module support
1. Using three screws, attach the dual power module support bracket.
2. Using two screws, attach the power module right-angle bracket to the front of the support.
3. Using six screws, attach the power module right-angle bracket to the back of the support, then to the C1G.
4. Using three screws, attach the support to the front right-angle bracket.
5. Using three screws, attach the right-angle rack mounting bracket to the C1G.
Front
Front
Casa Systems C1G CMTS
Installing the system in a rackHardware Installation Guide2-6
Figure 2-2 shows the complete rack mounting kit installation. Figure 2-3 illustrates a sample rack installation with multiple C1G systems.
Figure 2-2. C1G system with rack mounting kit
Figure 2-3. Sample C1G CMTS rack installation
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
1. To populate rack, start from the first available postion from the bottom of the rack.
2. Install four screws (two per mounting ear) and turn clockwise to tighten.
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
Casa Systems C1G CMTS
Installing the optional wall mountInstalling the C1G hardware 2-7
Installing the optional wall mountCasa provides a C1G wall mounting option for installations where a computer rack is not readily available or feasible, or if the installation space is limited. The C1G wall mounting components attach to any flat wall surface. Since the system is mounted flush (similar to hanging a picture on a wall) with approximately 0.30 inches of clearance between the unit and the wall, you only need to ensure adequate mounting points and a surface area large enough for the system and the system cabling.
There are currently two wall mounting options:
1. The standard wall mount kit, and
2. The standard wall mount with a remote standalone dual power module holder. See “Using the standalone dual power module pocket.”
Figures 2-4 illustrate the wall mount bracket installation.
Figure 2-4. C1G wall mount bracket installation
Top viewC1G system Using three screws, attach the right-angle rack
mounting brackets to the C1G; attach one on the right and one on the left.
FrontTo mount, you will need a level, power drill and bits, mounting bolts or screws, appropriately-sized washers, and wall anchors for the type of wall at your installation location. Casa does not include this hardware due to the many variationsavailable for differing types of wall construction.
Casa Systems C1G CMTS
Using the standalone dual power module pocketHardware Installation Guide2-8
Using the standalone dual power module pocketThe standalone dual power module pocket allows you to mount the C1G power modules at a location near the C1G chassis. You can use this standalone design for any type of installation, as shown in Figure 2-5.
Figure 2-5. Standalone dual power module pocket assembly
Power module support pocket
Power module supportwith module inserted.
1. Insert the power modules into the module supports.
Casa Systems C1G CMTS
Using the standalone dual power module pocketInstalling the C1G hardware 2-9
To mount the standalone dual power module pocket assembly, you will need a level, power drill and bits, mounting bolts or screws, appropriately-sized washers, and wall anchors for the type of wall at your installation location. Casa does not include this hardware due to the many variations available for differing types of wall construction.
Casa Systems C1G CMTS
3-1
Chapter 3. Connecting and startingthe C1G
This chapter covers the procedures for connecting the C1G and starting the system. It includes the following topics:
Topic Page
Connecting the Gigabit Ethernet ports 3-2
Installing SFP modules 3-2
Connecting Ethernet to the SFP 3-3
Removing Ethernet cables and the SFP module 3-4
Connecting to the console port 3-4
Connecting the RF I/O ports 3-7
Connecting the DC power modules 3-8
Starting the C1G CMTS 3-10
Casa Systems C1G CMTS
Connecting the Gigabit Ethernet portsHardware Installation Guide3-2
Connecting the Gigabit Ethernet portsThe network uplink connections are made through the GigE Ethernet (GigE) ports.
The GigE ports labeled G0 and G1 support IEEE 802.3z and IEEE 802.3ab specifications for 1000BASE-T/-X (1000 Mbps) transmission over fiber-optic cables and standard CAT5/CAT6 cables. These ports also support auto-sensing and auto-negotiation of the proper transmission mode (half duplex or full duplex) with an attached device.
GigE port G0 uses an SFP (Small Form-factor Pluggable) module.
Installing SFP modules
The GigE ports labeled G0 and G1 require the insertion of an SFP module (SFP-CP copper or SFP-LC fiber), as illustrated in Figure 3-1. The following warning applies to fiber-optic SFPs.
Figure 3-1. Sample SFP module
To insert an SFP module into port GigE G0:
Warning: Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments.
Casa Systems C1G CMTS
Connecting the Gigabit Ethernet portsConnecting and starting the C1G 3-3
1. For optical SFP modules, locate the transmit (TX) and the receive (RX) markings that identify the topside of the SFP module.
2. Align the back (receive) end of the SFP module with the front faceplate, then insert the module into the G0 port until you feel the connector snap into place.
3. Remove the dust plugs from the optical ports, and store them for later use.
Connecting Ethernet to the SFP
To connect Ethernet cables to the SFPs in ports G0 and G1, insert the Ethernet cable into the front (transmit) end of the SFP module, as illustrated in Figure 3-2.
Figure 3-2. Connecting Gigabit Ethernet ports
Note: On some modules, the TX and RX markings might be replaced by arrowheads. These point out of the module connector to signify the transmit direction, and into the connector to indicate the receive direction.
GigE 0
DS US0 US1G0
Copper orfiber SFP
GigE 1
G1
Insert Ethernet RJ-45 (copper) or LC (fiber optic) connectors into SFP.
Casa Systems C1G CMTS
Connecting to the console portHardware Installation Guide3-4
Removing Ethernet cables and the SFP module
To remove an SFP module:
1. Remove the cable from the front end of the SFP module in G0 or G1. To release the lock on the SFP, pull the SFP module release lever down until it stops.
2. Slide the module out of the receptacle.
Replace the dust plugs on the optical ports for protection.
Connecting to the console port
The console port provides local administrative access to the C1G and the command-line interface (CLI) over a serial EIA-561 RS232D connection with a DTE interface using a male RJ-45 plug. Attaching a terminal or PC allows you to connect to the system CLI for initial setup at the deployed location.
To connect a terminal or PC to the RJ-45 console port, you need a DB-9 to DB-9 serial crossover cable and the supplied RJ-45 to DB-9 adapter.
Figure 3-3 illustrates the RJ-45 and lists the pin/signal information.
Casa Systems C1G CMTS
Connecting to the console portConnecting and starting the C1G 3-5
Figure 3-3. .RS-232 pinouts on console port
A console connection kit is shipped with each C1G system. The kit includes the following components:
• One standard Category 5 UTP RJ-45-to-RJ-45 cable
• One RJ-45 to DB-9 adapter
• One DB9-to-DB9 serial crossover console cable (also called a null modem cable)
Use these components to connect the console port to a terminal or PC, as illustrated in Figure 3-4.
1. Connect one end of the RJ-45 cable to the serial RJ-45 port.
2. Connect the other end of the cable to the RJ-45-to-DB-9 adapter.
3. Connect the adapter to the appropriate serial port on the PC or terminal to complete the console port cable connection.
4. Power on the PC or terminal.
5. Configure the PC terminal emulation software or the terminal for the following default settings:
• 115200 baud
Pin Signal
1 RTS Request to Send 2 DTR Data Terminal Ready 3 TXD Transmit Data (OUT)4 GND Ground 5 CTS Clear to Send6 RXD Receive Data (IN)7 DCD Data Carrier Detect8 DSR Data Set Ready
1
RJ-45 socket on SMM
8
Casa Systems C1G CMTS
Connecting to the console portHardware Installation Guide3-6
• 8 data bits
• No parity generation or checking
• 1 stop bit
• No flow control
Figure 3-4. C1G console port connections
RJ-45 to DB-9adapter
RJ-45 to RJ-45 cable
Terminal or PCwith DB-9serial port.
RS-232 local console port(RJ45)
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
Casa Systems C1G CMTS
Connecting the RF I/O portsConnecting and starting the C1G 3-7
Connecting the RF I/O ports Connect the RF I/O upstream and downstream ports to the HFC network, as illustrated in Figure 3-5:
1. Attach the 75-ohm F-connector on one end of the cable to the RF connector on the faceplate of RF I/O module.
2. Attach the other end of the cable to the equipment that acts as a gateway to the HFC network, using the appropriate type of connector for your HFC distribution equipment.
Figure 3-5. Connecting the upstream and downstream ports.
Caution: When connecting the cable F-connector to the RF connector on the RF I/O module, ALWAYS use a torque wrench to set the tightness to 15 inch-lbs (1.7 Newton-meters) Do not simply hand-tighten the F-connectors. F-connectors that are too loose can cause RF leakage. F-connectors that are too tight can damage the RF port electronics.
Secure RG6 F-connectorsto upstream and downstreamports. Tighten to 15 inch-lbs of torque.
DQM QAMdownstreamRF output
DCU upstreamRF burst receiver inputs
DS US0 US1G0
10/100M 1000M
Casa Systems C1G CMTS
Connecting the DC power modulesHardware Installation Guide3-8
Connecting the DC power modulesLocate the two DC power modules included with the C1G. The modules provide redundant 12V DC power to the system by converting the each 120VAC voltage source. The DC power modules are designed to fit and drop into the dual power module support attached to the left side of the system, as covered in Chapter 2, “Installing the C1G hardware.”
Perform the following steps:
1. Without the power cords installed, insert and place the two DC power modules into the power supply bays and at the same time, route the cables that go to the A and B power inputs through the hole provided in the rack-mount sheet metal
2. Plug-in the A and B inputs to the C1G.
3. At the back of the system, plug in the two AC power cords.
4. When ready, plug in the power cords into the AC power outlets.
Figure 3-6 shows the redundant power module hookups.
Casa Systems C1G CMTS
Connecting the DC power modulesConnecting and starting the C1G 3-9
Figure 3-6. Connecting redundant DC power
Removable power plug to AC power source(country cord specific)
Top viewC1G system
DC powermodule bays
Front
DC power inputplugs (A, B)
10101
�
CASA SYSTEMSC1G
l
0PWR A PWR B
CASA
AC power cordto power source
Route cablesthrough sheet metal
Power ON/OFF switch
Casa Systems C1G CMTS
Starting the C1G CMTSHardware Installation Guide3-10
Starting the C1G CMTS After installing the C1G and connecting the required cables, perform a visual check of all connections and then check that:
• All network interface cables are connected.
• The console terminal is turned on.
You are now ready to power on the system for the first time using the procedures below. The first time you power the system on, the system software will automatically upload default configuration loaded in the C1G.
1. At the C1G, press the toggle switch to the ON ( | ) position. Listen for the fans. You should immediately hear them operating.
2. Verify all LEDs are lighting properly. The green status LED on the system front panel should be lit. See Table 3-1.
The console screen should display a system banner followed by a system prompt:
CASA-C1G>
See the Casa Systems – CMTS Software Configuration Guide for information on configuring the system for your network.
Refer to the Casa Systems – C1G CMTS Release Notes for information on the currently-supported C1G capacities.
Table 3-1. C1G LED indications
Location LED Color Indication
Front panel Status Green System turned on; running normally.
Black (off) No power condition; system off.
Alarm Black Normal operation; no alarms present while system status remains in the green state.
Red Error condition detected.
GigE port G0, G1
(L)ink status
Green Ethernet link up and connected.
Black (off) Ethernet link down; no connection
(A)ctivity Green Ethernet link is transmitting or receiving data.
Black No network activity currently present on link.
Casa Systems C1G CMTS
A-1
Appendix A. C1G hardwarespecifications
This appendix covers the hardware specifications for the Casa C1G CMTS and all installed components. For additional specifications related to DOCSIS and IP features, refer to the Casa Systems C1G CMTS Data Sheet.
Topic Page
Physical, electrical, and environmental A-2
Safety and regulatory compliance A-3
Chassis components and capacities A-4
DOCSIS QAM interface specifications A-5
DOCSIS upstream interface specifications A-6
C1G component ordering A-6
Casa Systems C1G CMTS
Physical, electrical, and environmentalHardware Installation GuideA-2
Physical, electrical, and environmental
Table A-1. C1G CMTS specifications
Parameter Specification
Physical
Dimensions Height: 1.75 in. (44.4 mm)Width: 8.75 in. (223 mm)Depth: 15 in. (379 mm)
Mounting standard 1 RU, 19 inches with DC power module support and rack-mounting hardware installed
Weight 6 lbs (2.72 kg)
LEDs Alarm, system status
Electrical
Input AC power consumption
Voltage<150W nominal110 to 240 VAC
DC power module to chassis
Voltage12 VDC (redundant)
Environmental
Temperature Operating: 0° to 50° CStorage: -40° to 70° C
Humidity Relative: 5%° to 95%Storage: 5% to 95%
Altitude Operating: Sea level to 6562 ft (2000M)Storage: Sea level to 15,748 ft (4800M)
Casa Systems C1G CMTS
Safety and regulatory complianceHardware Installation Guide A-3
Safety and regulatory compliance
The C1G complies with the safety and regulatory agency standards listed below when installed in accordance with this guide.
Product safety
Representative samples of this product have been evaluated by a Nationally Recognized Test Laboratory (NRTL) and meet the applicable U.S., Canadian, and International safety standards:
• ANSI/UL 60950-1 - UL Standard for Safety for Information Technology Equipment Safety.
• EN/UL/IEC/CAN/CSA C22.2 No. 60950-1 - Standard for Safety for Information Technology Equipment Safety.
• EN60950-1
Grounding
AC-power source is grounded through the ground (GND) wire in the AC power cord. There is no separate grounding connection.
DC power to the chassis is grounded through the DC power module.
EMC
The C1G has been tested and meets the following requirements:
• EN55022, Class A
• EN55024
• FCC Part 15 Class A, subpart B, CISPR Class A
Immunity
• EN61000-4
Casa Systems C1G CMTS
Chassis components and capacitiesHardware Installation GuideA-4
Chassis components and capacities
Table A-2. C1G capacities
Component Description
Chassis 1 rack unit (RU), industry standard 19-inch rack mountable
AC power source (2) 100 to 240 VAC to each DC power conversion module
DC power supply (2) 12 VDC power to the chassis per DC power module
Front panel LEDS Alarm, system status
Rear panel LEDs RF port status
System fans • Three integrated 1RU-compatible cooling fans for redundancy
• Front to back air flow
• Single-speed operation
Interfaces • Two GigE interface (copper or fiber SFP) with Link and Activity LEDs
• One RS-232 console port (RJ45); max serial data rate at 115 Kbps
• 2x1 Gbps switching capacity
• One downstream interface per system
• Two upstream interfaces system
DOCSIS QAM downstream interface
• 1 port per system
• 8 QAM downstream channels per port
• QAM mode:Annex A: 8 MHzAnnex B: 6 MHzAnnex C: 6 MHz
• QAM constellation:Annex A & C: 64, 128, 256Annex B: 64, 256
DOCSIS upstream interface • 1 to 2 ports per system
• 4 upstream channels per port
• Modulation: QPSK, 16,32,64, QAM
Casa Systems C1G CMTS
DOCSIS QAM interface specificationsHardware Installation Guide A-5
DOCSIS QAM interface specifications
Table A-3. DOCIS QAM specifications
Component/Parameter Specification
Number of ports 1 per system
Number of channels 8 channels per port
QAM modulation Annex A, B or C
QAM constellations 64, 128, & 256 QAM
Data rates (DOCSIS) 27 Mbps @ 64 QAM38 Mbps @ 256 QAM
Data rates (EuroDOCSIS) 36 Mbps @ 64 QAM51 Mbps @ 256 QAM
Connector F-type, 75 ohm
Frequency range (edge) 48 to 999 MHz
Frequency accuracy +/- 5 ppm
Frequency step size 5 kHz
Channel width 6 to 8 MHz (tunable)
Maximum output per channel 61 dBmV @ 1-ch/port57 dBmV @ 2-ch/port53 dBmV @ 4-ch/port
Output step size 0.1 dB
Return loss 50 ~ 870 MHz, 14 dB 870 ~ 1002 MHz 10 dB
Modulation error rate 43 dB (equalized)
Wideband noise -73dBc
Casa Systems C1G CMTS
DOCSIS upstream interface specificationsHardware Installation GuideA-6
DOCSIS upstream interface specifications
C1G component ordering
Table A-4. C1G DOCSIS upstream specifications
Component Specification
Number of ports 2 per system
Number of channels 4 channels per port
Modulation QPSK, 8, 16, 32 and 64 QAM
Data rate/channel 0.32 - 30.72 Mbps
Input frequency range 5 - 42 MHz (DOCSIS)5 - 65 MHz (EuroDOCSIS)5 - 55 MHz (J-DOCSIS)
Connector F-type, 75 ohm
Input range -4 to 26 dBmV
Table A-5. C1G components
Component Order number
C1G DC-powered chassis with integrated fan tassembly and DC power modules (2); dual SFP
C1G-CHASSIS-SFP-SFP
C1G DC power module (2 required for power redundancy (AC power cord is country specific)
C1G-POWER-MODULE-<country>
Pluggable devices
GigE Small Form Factor Pluggable (SFP) (RJ-45 socket, copper)
SFP-CP
GigE Small Form Factor Pluggable (SFP) (LC socket, fiber optic)
SFP-LC
Casa Systems C1G CMTS
C1G CMTSHardware Installation Guide
© 2012 Casa Systems, Inc.All rights reserved.
DOC-3012-01
Document Revision 01.00.02February 2012
Printed in United States of America
100 Old River RoadSuite 100Andover, MA 01810USA978-688-6706
top related