cast into footings
Post on 18-Dec-2021
8 Views
Preview:
TRANSCRIPT
Project: New ResidenceClient: Harley TruongDrawn: Harley Truong
Address: 10 Anderson St Chifley Canberra
Block: 1
Scale @ A3 1:100
Drawing No C02.7
Sec: 3
Date: 2.11.13
Revision: 12
Slab plan - House 1A
Revision Date Checked Approved 12 2.11.13 HT HT11 18.10.13 HT HT10 1.8.13 HT HT
0 5
north
100
450
24570
450
2400 753050mm SETDOWN
400
800
8790
7590
50505050
20
150
120
FOR CONSTRUCTION9mm PLYWOOD CLADDINGTO GARAGE
3740
450
450
450
450 5520560045056004505600
8240
450
1FOOTINGSScale: 1 : 100
2SLABScale: 1 : 100
ASECTIONScale: 1 : 20
MIN 450mm WIDE x 450mm DEEP20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS
1800
2395
6000
120
400LAP
2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANE TYPMIN 200um
DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP
18210
7350
DAMP PROOF MEMBRANEMIN 200um POLYTHENE
120mm 32MPa CONCRETE DRIVEWAY SL82 TOP AND BOTTOM
BDRIVEWAYScale: 1 : 20
120mm WITH 150mmEDGE THICKENING32MPa SLABSL82 TOP AND BOTTOMON MIN 200umPOLYTHENE.STEEL TROWEL FINISH
120
120
6180
350
900 TYP
REFER PLUMBING PLAN C2.29FOR LOCATION OF SLAB PENETRATIONS
100mm 32MPa SLABSL82 TOP ON MIN 200umDPM
STEEL TROWEL FINISH
UNDISTURBED SOIL
'OZONE' SIP PANELS 15mm UNTREATED OSB 90mm PIR FOAM 15mm UNTREATED OSB
TO BE INSTALLED TOMANUFACTURER SPECSWITH 3mm x 55mm RINGSHAFT NAILS AT 150mm CNTRSTO TOP AND BOTTOM PLATES AND STUDS
FFL HOUSE
20mm CORK FLOORING
70
A
2500
100mm 32MPa SLABSL82 TOP ON MIN 200umDPM
STEEL TROWEL FINISH
* H3 TREATED SOLE PLATE* H3 TREATED BOTTOM PLATE* COAT BOTTOM 150mm OF OSBWITH BRUSH ONCHEMICAL PRESERVATIVE
WALL CLADDING 19mm SCYON BATTEN 8mm SCYON MATRIX
XPS FOAM MIN 220kPa COMPRESSIVE STRENGTH @ 10% DEFLECTION3 x 50mm LAYERS(CERTIFICATION ON FIT-FOR-PURPOSETO BCA REQUIRED BY SUPPLIER)
50
MIN 80mmEXPOSED SLABEDGE FOR TERMITEINSPECTION ASPER AS3660.1
100
COMPACTEDFILL
50mm WET AREASLAB SETDOWN
M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN
WALLS INSTALLED FIRSTAND THEN USED AS FORMWORK FOR HOUSE AND GARAGE SLABS
150MIN
MIN 150
N12PERIMETERBAR TYP
N12 PERIMETER BARWITH MIN
600mm LAPS TYP
2000 TYP
2000 TYP
FFL GARAGE
B
SL82 TOPALCORALUMINIUMSLIP JOINT300um TYP
2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANEMIN 200um TYP
DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP
MIN 450mm DEEP x 450mm WIDE 20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS
ALCORALUMINIUMSLIP JOINT300um TYP
100TYP
1750
200 x 160 x 12mmGALV BASE PLATES CAST INTO FOOTINGSWITH 4 X M12 THREADEDRODS
VAPOUR PERMEABLEMEMBRANE
M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN,100mm PROTUDING ABOVE FOOTING
60 TYP
Project: New ResidenceClient: Harley TruongDrawn: Harley Truong
Address: 10 Anderson St Chifley Canberra
Block: 1
Scale @ A3 1:100
Drawing No C02.8
Sec: 3
Date: 2.11.13
Revision: 4
Slab plan - House 1B
Revision Date Checked Approved 4 2.11.13 HT HT3 18.10.13 HT HT2 1.8.13 HT HT
0 5
north
100
450
22170
450
2400753050mm SETDOWN
400
800
8790
7590
50505050
20
150
120
FOR CONSTRUCTION9mm PLYWOOD CLADDINGTO GARAGE
3740
450
450
450
4503120 5600 450 5600 450 5600
5840
450
1FOOTINGSScale: 1 : 100
2SLABScale: 1 : 100
ASECTIONScale: 1 : 20
MIN 450mm WIDE x 450mm DEEP20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS
2395
3600
120
400LAP
2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANE TYP
DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP
18210
7350
DAMP PROOF MEMBRANEMIN 200um POLYTHENE
120mm 32MPaCONCRETE DRIVEWAYSL82 TOP AND BOTTOM
BDRIVEWAYScale: 1 : 20
120mm WITH 150mmEDGE THICKENING32MPa SLABSL82 TOPAND BOTTOMON MIN 200umPOLYTHENE.STEEL TROWEL FINISH
120
120
100mm 32MPa SLABSL82 TOP ON MIN 200um DPM
STEEL TROWEL FINISH
UNDISTURBED SOIL
'OZONE' SIP PANELS 15mm UNTREATED OSB 90mm PIR FOAM 15mm UNTREATED OSB
TO BE INSTALLED TOMANUFACTURER SPECSWITH 3mm x 55mm RINGSHAFT NAILS AT 150mm CNTRSTO TOP AND BOTTOM PLATESAND STUDS
MIN 450mm WIDE x 450mm DEEP 20MPa STRIP FOOTING WITH4-11 T-M TOP AND BOTTOMAND 300mm HIGH STEEL CLIPSAT 900mm CTRS
FFL HOUSE
20mm CORK FLOORING
70
A
2500
100mm 32MPa SLABSL82 TOP ON MIN 200umDPM
STEEL TROWEL FINISH
* H3 TREATED SOLE PLATE* H3 TREATED BOTTOM PLATE* BRUSH BOTTOM 150mm OF OSBWITH CHEMICAL PRESERVATIVE
SLOPE GROUNDAWAY FROMFOOTINGS
WALL CLADDING 19mm SCYON BATTEN 8mm SCYON MATRIX
XPS FOAM MIN 220kPa COMPRESSIVE STRENGTH @ 10% DEFLECTION3 x 50mm LAYERS(CERTIFICATION ON FIT-FOR-PURPOSETO BCA REQUIRED BY SUPPLIER)
50
MIN 80mmEXPOSED SLABEDGE FOR TERMITEINSPECTION ASPER AS3660.1
100
COMPACTEDFILL
50mm WET AREASLAB SETDOWN
M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN
WALLS INSTALLED FIRSTAND THEN USED AS FORMWORK FOR HOUSE AND GARAGE SLABS
150MIN
MIN 150
N12PERIMETERBAR TYP
N12 PERIMETER BARWITH MIN
600mm LAPS TYP
2000 TYP
2000 TYP
FFL GARAGE
B
SL82 TOPALCORALUMINIUMSLIP JOINT300um TYP
2 IN 1TERMITE BARRIER,DAMP PROOFMEMBRANE TYP200um
DAMP PROOF MEMBRANEMIN 200um POLYTHENE TYP
ALCORALUMINIUMSLIP JOINT300um TYP
100TYP
1800
350
900 TYP
1750
200 x 160 x 12mmGALV BASE PLATES CAST INTO FOOTINGSWITH 4 X M12 THREADEDRODS
60 TYP
M10 GALV THREADEDROD CAST INTO FOOTINGSAT 900mm CTRS, 200mm DEEP MIN,100mm PROTUDING ABOVE FOOTING
REFER PLUMBING PLAN C2.30FOR LOCATION OF SLAB PENETRATIONS
VAPOUR PERMEABLEMEMBRANE
3780