User ManualCityLink
B4008 Rev. M
© Nera Networks AS
Section I : Equipment Description
Section II : ODU Type I Installation
Section III : ODU Type II Installation
Section IV : ODU Type III Installation
Section V : IDU Installation
Section VI : Preparations for Operation
Section VII : Configuration with NEW-NMS
Section VIII : Fast Ethernet Configuration
Section IX : Troubleshooting
Section X : Appendices
2 B4008 Rev. M
CityLink
This section applies only to CE marked equipment
0889WARNING:Use of this equipment requires a separatelicense to be applied for by the operator.
DECLARATION OF CONFORMITY (INFORMAL)
English Hereby, Nera Networks AS, declares that this CityLink is in compliance with theessential requirements and other relevant provisions of Directive 1999/5/EC.
Finnish Nera Networks AS vakuuttaa täten että CityLink tyyppinen laite on direktiivin 1999/5/EYoleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Dutch Hierbij verklaart Nera Networks AS dat het toestel CityLink in overeenstemming is metde essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EGBij deze verklaart Nera Networks AS dat deze CityLink voldoet aan de essentiële eisenen aan de overige relevante bepalingen van Richtlijn 1999/5/EC.
French Par la présente Nera Networks AS déclare que l’appareil CityLink est conforme auxexigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.Par la présente, Nera Networks AS déclare que ce CityLink est conforme aux exigencesessentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables.
Swedish Härmed intygar Nera Networks AS att denna CityLink står I överensstämmelse med deväsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv1999/5/EG.
Danish Undertegnede Nera Networks AS erklærer herved, at følgende udstyr CityLink overhold-er de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF
German Hiermit erklärt Nera Networks AS, dass sich dieser CityLink in Übereinstimmung mitden grundlegenden Anforderungen und den anderen relevanten Vorschriften der Rich-tlinie 1999/5/EG befindet“. (BMWi)Hiermit erklärt Nera Networks AS die Übereinstimmung des Gerätes CityLink mit dengrundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie1999/5/EG. (Wien)
Refer to Declaration of Conformity for further details.
B4008 Rev. M 3
CityLink
4 B4008 Rev. M
CityLink
B4008 Rev. M 5
CityLink
6 B4008 Rev. M
CityLink
B4008 Rev. M 7
CityLink
WARNING!
DO NOT remove or insert theTransmitter Unit with DC power on.
Power to the OutDoor Unit (ODU) is carried onthe coaxial cable between the InDoor Unit(IDU) and the ODU. Before connecting orremoving the cable, ensure that the primarypower to the IDU has been switched off.
WARNING!
This equipment contains components which aresensitive to "ESD" (Electro Static Discharge).
It is therefore essential that whenever disassem-bling the equipment and/or handling PC boards,special precautions to avoid ESD have to bemade.
These precautions include personnel grounding,grounding of work bench, grounding of tools andinstruments as well as transport and storage inspecial antistatic bags and boxes.
CLASS 1 LASER PRODUCT
IEC825-2: 1993
CAUTION!
The Optical Interface must only be serviced byqualified personnel, who are aware of thehazards involved to repair Laser products.
When handling Laser products the followingprecautions must be taken:
Never look directly into an open connectoror optical cable
Before disconnecting an optical cable, thepower should be switched off. If this is notpossible, the cable must be disconnectedfrom the STM-1 output before it is discon-nected from the STM-1 input.
When the cable is reconnected it must beconnected to the STM-1 input before it isconnected to the STM-1 output.
CAUTION!Exposure to strong high frequency electromag-netic fields may cause thermal damage topersonnel. The eye (Cornea and lens) is easilyexposed.
Any unnecessary exposure is undesirable andshould be avoided.
In Radio-Relay communication installations,orderly setup for normal operation, the generalRF radiation level will be well below the safetylimit.
In the antennas and directly in front of them theRF intensity normally will exceed the dangerlevel, within limited portions of space.
Dangerous radiation may be found in theneighbourhood of open waveguide flanges orhorns where the power is radiated into space.
To avoid dangerous radiation the followingprecautions must be taken:
During work within and close to the frontof the antenna; make sure that transmitterswill remain turned off.
Before opening coaxial - or waveguideconnectors carrying RF power, turn offtransmitters.
Consider any incidentally open RFconnector as carrying power, untilotherwise proved. Do not look into coaxialconnectors at closer than reading distance(30 cm). Do not look into an open wave-guide unless you are absolutely sure thatthe power is turned off.
Use of controls or adjustments or perform-ance of procedures other than those specifiedherein may result in hazardous radiationexposure.
8 B4008 Rev. M
CityLink
List of Revisions
Rev. Date What is changed
C 01-10-05 ODU Type II Installation introducedD 01-12-18 ODU Type III Installation introducedE 02-02-28 Section II; 13 & 15GHz ODU included.
Section IV; Additional info on installation added.Section VII Chapter 5.2 Switch Criteria changed.Section IX: Additional info about connectors and interfacesin Appendix 1
F 02-05-07 Fast Ethernet introducedSection VII; New subchapter 5.1.5 Reconfiguring a 1+0IDU for use in Hot StandBy Configuration
G 02-09-18 21x2Mbit/s (CityLink ADM) introduced.Section VIII: Updated bitmaps in Ch. 16.6 and 16.8.
H 02-10-07 Frequency tuning of 13GHz Transceiver included (Section IIChapter 5.0).
I Not usedJ 02-12-19 Section V: New chapter 4.0 Installation of 21x2Mbit/s
Tributary UnitK 03-05-23 Section II: Chapter 5.0; new frequency (Table II-5)
Installation of ODU Type I on Type III suspension introducedSection IV: New subchapter: Mounting the transceiver(without antenna) to a column.Section VIII: Changed bitmaps in Ch. 16.1, 16.2, 16.6 and16.8, Changes in Ch. 8.9.1 and 8.9.2. New commandsincluded in Ch. 3.0 and 4.0.Section X: New alarms in Alarm list
L 03-11-25 DMD IDU introduced. ADM STM-1 and DS3/E3 ext.boardsintroduced . New optical interfaces (2NYD5392A and2NYD5368A) introduced.
M 04-10-26 New Version of NEW. (Section VII and VIII)Added info about System Configuration (Section I)Added info about IP Routing (Section VII)Section X: Improved description of Power Connector
B4008 Rev. M 9
CityLink
Table of Contents SECTION I Equipment Description .................. 21
1.0 Introduction ................................................................. 22
2.0 IDU ................................................................................ 242.1 IDU Description ................................................... 242.2 Hot Standby IDU Description............................... 262.3 Line Interface Boards .......................................... 282.4 Service Telephone .............................................. 282.5 21x2Mbit/s Extension Board (option) ................... 302.6 ADM STM-1 (X-Connect) Extension Board (option) 302.6 3xDS3/E3 and DS1 Extension Board (option) .... 322.6 Ethernet Extension Board (CityLink Fast Ethernet) 33
3.0 ODU .............................................................................. 343.1 ODU Type I Description ...................................... 343.2 ODU Type II Description ..................................... 363.3 ODU Type III Description ..................................... 38
4.0 Management ................................................................ 40
5.0 System Configurations ............................................... 405.1 1+0Configuration ................................................. 415.2 Hot Standby Configuration .................................. 425.3 1+1 Frequency Diversity ..................................... 425.4 Hot Standby Configuration – Dual Antenna ......... 435.5 Hot Standby Configuration – Dual Baseband ...... 445.6 2+0 Configuration ................................................ 455.7 Space Diversity ................................................... 465.8 Hybrid Space Diversity ........................................ 465.9 Radio Terminal Configurations ............................ 485.10 Radio Repeater Configurations ........................... 485.11 Radio Channel Identification ................................ 48
10 B4008 Rev. M
CityLink
4.0 ODU / Antenna Installation,Hot Standby Equipment and 2+0 Equipment ........... 70
SECTION II Installation of ODU Type I and Antenna................. 491.0 General ........................................................................ 50
1.1 Packing ............................................................... 501.2 Marking ................................................................ 501.3 Transportation ..................................................... 501.4 Radio Equipment Inventory Check ...................... 511.5 Preparation for Installation ................................... 511.6 Handling & Storage ............................................. 51
2.0 Installation Equipment required ................................ 522.1 Tools ................................................................... 522.1.1 Tools for Antenna Installation .............................. 522.1.2 Tools for IDU- ODU Cable /Connector Mounting. 522.2 Equipment external to the Radio Equipment ....... 53
3.0 ODU / Antenna Installation, 1+0 Equipment ............. 543.1 Installation of 0.6m and 0.45m Antenna ............. 543.1.1 Preparing the Suspension for ODU Mounting ..... 543.1.2 Mounting the Antenna to the Suspension ............ 553.1.3 Mounting the Branching Support Bracket ............ 563.1.4 Mounting the Rear Travers .................................. 573.1.5 Mounting the Suspension Support Bracket ......... 573.1.6 Mounting the Bend on the Branching Unit ........... 583.1.7 Installation of the Branching Unit ........................ 593.1.8 Attachment of the Sunshield Support .................. 593.1.9 Installation of the Flexible Waveguide ................ 603.1.10 Installation of the Sunshield ................................ 613.1.11 Mounting the Suspension/Antenna to
a Column or a Wall ............................................ 623.1.12 Mounting the ODU to the Antenna Assembly ..... 653.1.13 Pole Mount ......................................................... 673.2 Installation of 1.2m Antenna ............................... 683.2.1 Assembly of Branching Support Bracket ............ 683.2.3 Installation of Branching Unit,
Sun-shield and Flexible Waveguide .................... 69
B4008 Rev. M 11
CityLink
4.1 0.45m and 0.6m Antenna ................................ 704.1.1 Installation of Hot Standby (HSB) and 2+0
Dual Frequency Single Polarization Equipment . 704.1.1.1 Preparing the Suspension for ODU Mounting
and Mounting the Antenna to the Suspension . 704.1.1.2 Mounting the Branching Support Bracket ........ 704.1.1.3 Mounting the Rear Travers, Mounting the
Suspension Support Bracket and Mountingthe Feed on the Branching Unit ....................... 71
4.1.1.4 Installation of the HSB Branching Unit ............. 714.1.1.5 Installation of the Flexible Waveguide ............. 724.1.1.6 Installation of the Sunshield Support Bracket .. 734.1.1.7 Installation of the Sunshield............................. 734.1.1.8 Mounting the Suspension/ODU to a
Column or a Wall ............................................ 744.1.1.9 Mounting the ODU to the Antenna Assembly .. 744.1.1.10 Pole Mount ...................................................... 754.1.2 Installation of 2+0 Equipment
(Single Frequency Dual polarity) ..................... 764.1.2.1 Preparing the Suspension for ODU Mounting
and Mounting the Antenna to the Suspension . 764.1.2.2 Mounting the Branching Support Bracket, the
Rear Travers, the Suspension Support Bracketand the Feed on the Branching Units ................ 76
4.1.2.3 Installation of the Branching Units ................... 764.1.2.4 Installation of the Flexible Waveguide ............. 774.1.2.5 Installation of the Sunshield............................. 784.1.2.6 Mounting the Suspension/ODU to a
Column or a Wall ............................................ 794.1.2.7 Mounting the ODU to the Antenna Assembly .. 794.1.2.9 Pole Mount ...................................................... 804.2 1.2m Antenna .................................................. 814.2.1 Assembly of Branching Support Bracket ........ 814.2.2 Installation of Branching Unit, Sun-shield and
Flexible Waveguide ......................................... 824.2.2.1 Hot Standby and
2+0 Dual Frequency Single Polarization ......... 824.2.2.2 2+0 Single Frequency Dual Polarization ......... 83
12 B4008 Rev. M
CityLink
5.0 Frequency Tuning at 13GHz &15GHz Transceiver ... 84
6.0 Cable Connections ..................................................... 90
7.0 Antenna Alignment ...................................................... 90
SECTION III Installation ofODU Type II and Antenna .................. 91
1.0 General ........................................................................ 921.1 Packing ............................................................... 921.2 Marking ................................................................ 921.3 Transportation ..................................................... 921.4 Radio Equipment Inventory Check ...................... 931.5 Preparation for Installation ................................... 931.6 Handling & Storage ............................................. 93
2.0 Installation Equipment required ................................ 942.1 Tools ................................................................... 942.1.1 Tools for Antenna Installation .............................. 942.1.2 Tools for IDU- ODU Cable /Connector Mounting. 942.2 Equipment external to the Radio Equipment ....... 95
3.0 ODU Installation .......................................................... 963.1 Mounting the ODU to the Pole ............................. 963.2 Cable Connections.............................................. 97
4.0 Antenna and Waveguide Installation ........................ 984.1 0.6m Antenna ...................................................... 984.2 1.2m Antenna ...................................................... 994.3 2m Antenna ......................................................... 1004.4 2.4m .................................................................... 1014.5 3m ....................................................................... 102
B4008 Rev. M 13
CityLink
SECTION IV Installation ofODU Type III and Antenna ............ 103
1.0 General ........................................................................ 1041.1 Packing ............................................................... 1041.2 Marking ................................................................ 1041.3 Transportation ..................................................... 1041.4 Radio Equipment Inventory Check ...................... 1051.5 Preparation for Installation ................................... 1051.6 Handling & Storage ............................................. 105
2.0 Installation Equipment required ................................ 1062.1 Tools ................................................................... 1062.1.1 Tools for Antenna Installation and Adjustment .... 1062.1.2 Tools for IDU- ODU Cable /Connector Mounting. 1062.2 Equipment external to the Radio Equipment ....... 107
3.0 ODU / Antenna Installation, 1+0 Equipment ............. 1083.1 Mounting the Antenna to the Suspension ............ 1083.2 Mounting the Sunshield ....................................... 1093.3 Mounting the Suspension/Antenna to
a Column by using the U-bolts ............................ 1103.4 Mounting the Suspension/Antenna to
a Column by using the Clamps ........................... 1113.5 Mounting the Transceiver
(without Antenna) to a Column ............................ 1123.6 Mounting the Suspension/Antenna to a Wall ....... 1173.7 Mounting the ODU to the Antenna Assembly ...... 118
4.0 ODU / Antenna Installation, HSB and 2+0 Equipment 1214.1 Preparing the Suspension ................................... 1214.2 Mounting the Antenna to the Supension .............. 1224.3 Mounting the Hybrid Frame to the Antenna ......... 1234.3 Mounting the CityLink III ODUs to
the Antenna Assembly ........................................ 1254.4 Mounting the Transceiver
(without Antenna) to the Column ......................... 1264.5 Mounting the Suspension/Antenna to a Wall ....... 126
14 B4008 Rev. M
CityLink
5.0 Cable Connections ..................................................... 127
6.0 Antenna Alignment ...................................................... 1286.1 Azimuth and Elevation Adjustment ...................... 1286.2 Coarse adjustment. ............................................. 1286.3 Fine adjustment .................................................. 1286.4 Final Control ........................................................ 1296.5 Polarisation alignment ......................................... 129
SECTION V IDU Installation............................... 131
1.0 General ........................................................................ 1321.1 Packing ............................................................... 1321.2 Marking ................................................................ 1321.3 Transportation ..................................................... 1321.4 Radio Equipment Inventory Check ...................... 1331.5 Preparation for Installation ................................... 1331.6 Handling & Storage ............................................. 133
2.0 IDU Installation ............................................................ 1342.1. Mounting the IDU in an ANSI (19") or an ETSI Rack ... 1342.2 Cable Installation ................................................. 135
3.0 Hot Standby IDU Installation ...................................... 1363.1 Mounting the Hot Standby IDUs in a Rack ........... 1363.2 Interconnections in a Hot Standby System ......... 137
4.0 Installation of Optional Extension Boards ............... 138
5.0 IDU/ODU Cable Installation........................................ 141
6.0 Change of Fan-Cassette ............................................ 146
SECTION VI Preparations for Operation ........ 147
1.0 General ........................................................................ 148
B4008 Rev. M 15
CityLink
1.1 Equipment required ............................................. 1481.2 Connections ........................................................ 148
2.0 Power on ...................................................................... 1482.1 NEW-NMS/NEW-Configurator Startup and
connecting to Network Elements ........................ 1492.1.1 Starting NEW-NMS/NEW-Configurator with
Serial Connection (RS-232/ LCT). ...................... 1492.1.2 Starting NEW-NMS/NEW-Configurator with
TCP/IP Connection. ............................................ 1502.2 Initial configuration ............................................... 150
SECTION VII Configuration by NEW Configurator 151
1.0 General ........................................................................ 152
2.0 Element Node .............................................................. 1542.1 Element Id ........................................................... 1542.2 Available Functions ............................................. 1562.3 Notifications......................................................... 1572.4 NE Clock Page .................................................... 1592.5 Software Download ............................................. 1602.6 Software Versions ............................................... 161
3.0 Transmission Node..................................................... 1633.1 Section Termination ............................................ 1633.1.1 Section Termination, SW-version < R2A00 ........ 1633.1.2 Section Termination, SW-version ³ R2A00 ......... 1643.1.3 SSM - Synchronization Status Message ............. 1723.2 Alarm Indication Signal Insert .............................. 1733.3 Path Trace .......................................................... 176
4.0 Equipment Node ......................................................... 1784.1 Network Routing .................................................. 1784.2 IP Routing............................................................ 1814.2.1 General Settings ................................................. 1824.2.2 Active Routes ...................................................... 184
16 B4008 Rev. M
CityLink
4.2.3 Static Routes ...................................................... 1854.2.4 RIP Interfaces ..................................................... 1864.2.5 OSPF Interfaces ................................................. 1874.2.6 OSPF Areas........................................................ 1884.3 Communication Ports ......................................... 1894.3.1 DCC (Data Communication Channel) ................ 1894.3.2 NI (Network Interface) .......................................... 1914.3.3 LCT ..................................................................... 1934.3.4 Ethernet .............................................................. 1944.3.5 IP Settings ........................................................... 1954.3.6 IP Tunneling ........................................................ 1964.3.7 OSI TP4 Tunneling .............................................. 1974.4 Looping ............................................................... 1984.4.1 Main Looping ....................................................... 1984.4.2 64 Kbit/s Looping ................................................ 2004.4.3 2 Mbit/s Wayside Looping ................................... 2024.4.4 21x2Mbit/s Looping.............................................. 2054.4.5 DS3/E3 Looping .................................................. 2074.5 In Door Unit (IDU) ................................................ 2104.5.1 IDU Production Data ........................................... 2104.5.2 64 kbit/s Channels .............................................. 2114.5.3 2 Mbit/s Wayside Channel .................................. 2134.5.4 SOH X-Connect .................................................. 2154.5.5 Error Pulse Output .............................................. 2164.5.6 Auxiliary Output Configuration ............................. 2174.5.7 Diagnose ............................................................. 2194.5.8 Self Test .............................................................. 2204.5.9 BER Thresholds ................................................. 2204.5.10OSI Configuration ................................................ 2224.5.11Laser Control ...................................................... 2274.5.12IDU Replace Unit Wizard .................................... 2294.6 Out Door Unit (ODU)........................................... 2304.6.1 Type I ODU ......................................................... 2304.6.2 Type II ODU......................................................... 2354.6.3 Type III ODU ........................................................ 2474.6.4 Antenna Data ...................................................... 2524.6.5 ODU Replace Unit Wizard .................................. 253
5.0 CityLink ADM ............................................................... 254
B4008 Rev. M 17
CityLink
5.1 21x2 Mbit/s Extension Board ............................... 2545.1.1 Drop or Continue ................................................. 2545.1.2 PRBS Test - Check ............................................ 2585.1.3 PRBS Test - Generators ..................................... 2605.1.4 Production Data - 21x2Mbit/s Extension board ... 2625.2 DS3/E3 Extension Board .................................... 2635.2.1 DS3/E3 Configuration ......................................... 2635.2.2 DS3/E3 Frame Structure Configuration .............. 2655.3 ADM STM-1 Extension Board (X-Connect) ......... 2675.3.1 X-Connect Frame Structure Configuration .......... 2675.3.2 X-Connect Configuration ..................................... 268
6.0 Hot Standby ................................................................. 2706.1 General ............................................................... 2706.1.1 Functionality ........................................................ 2706.1.2 Element ID .......................................................... 2716.1.2 Looping Configuration ......................................... 2736.1.3 Hot Standby Configuration .................................. 2756.1.4 Hot Standby Switching Criteria ............................ 2766.1.4 Reconfiguring a Hot Standby IDU for
use in 1+0 Configuration ..................................... 2786.1.5 Reconfiguring a 1+0 IDU for
use in Hot StandBy Configuration ...................... 278
SECTION VIII CityLink Fast Ethernet Configuration 279
Hyperterminal & Telnet .................................................... 280
1.0 Hyperterminal & Telnet Commands .......................... 280
2.0 How to get this link alive ............................................ 2812.1 How to get this link alive, parameters .................. 2812.2 Testing ................................................................ 281
3.0 Top Level Commands ................................................ 2823.1 Top Level Commands, Example ......................... 283
18 B4008 Rev. M
CityLink
4.0 Submenu Commands.................................................. 2844.1 EEB Submenu .................................................... 2844.2 Baseband Submenu ........................................... 2854.3 Modem Submenu (part of IDU) ........................... 2864.4 Radio Submenu (part of ODU)............................ 2874.4.1 Radio Status, Example ....................................... 2884.4.2 Radio Commands, Example of Error Message .. 2884.5 SU Submenu (part of IDU) .................................. 2894.6 Security Submenu .............................................. 2894.7 Performance Submenu ....................................... 2904.8 Configuration Submenu ...................................... 2904.8.1 Management Settings ......................................... 2914.9 Test & Fault Submenu ........................................ 2914.10 Q1module Submenu ........................................... 292
5.0 Software Upgrade Procedure forthe CityLink Fast Ethernet Device ............................ 2935.1 How to download a file to the IDU: ....................... 2945.1.1 Using the Console FTP Client ............................. 2945.1.2 Using the Internet Explorer .................................. 2955.2 How to download a file to the ODU ..................... 296
NEW Network Management System ............................... 297
6.0 Start NEW-NMS & Connect........................................ 297
7.0 Network Element Configuration ................................ 300
8.0 Element Node .............................................................. 3028.1 Element Id ........................................................... 3028.2 NE Clock ............................................................. 3038.3 Software Versions ............................................... 3048.4 Production Data .................................................. 3058.5 SNMP Agent(s) Settings ..................................... 3068.6 Trap Table ........................................................... 3088.7 MIB II - System Group ......................................... 3098.8 MIB-II SNMP Group.............................................. 3118.9 Looping ............................................................... 3128.9.1 Main Traffic Loops ............................................... 313
B4008 Rev. M 19
CityLink
8.9.2 Wayside Loops ................................................... 3158.9.3 64 kbit/s Loops .................................................... 316
9.0 In Door Unit (IDU) ....................................................... 3179.1 64 kbit/s Channels .............................................. 3179.2 Ethernet Extension Board ................................... 3179.2.1 Ethernet Ports ..................................................... 3189.2.2 2 Mbit/s Ports ...................................................... 3199.3 Wayside Channel ................................................ 3209.4 Auxiliary Output ................................................... 3219.5 BER Thresholds ................................................. 3239.6 Laser Control ...................................................... 325
10.0 Out Door Unit (ODU) .................................................. 32710.1 Antenna Data ...................................................... 32710.2 Power Settings .................................................... 32810.3 Frequency Settings ............................................. 330
11.0 Performance ................................................................ 33211.1 G826 Performance.............................................. 33211.2 Port Performance ............................................... 33411.3 Repeater Performance ....................................... 335
12.0 Fault .............................................................................. 33612.1 NE Alarm Log ...................................................... 336
13.0 Security ........................................................................ 33713.1 Security Log ........................................................ 337
SNMP & MIB Description ................................................. 338
14.0 General ........................................................................ 338
15.0 Supported MIB’s ......................................................... 338
16.0 MIB Overview ............................................................. 33916.1 Unit ...................................................................... 34016.2 IDU ...................................................................... 341
20 B4008 Rev. M
CityLink
16.3 ODU .................................................................... 34216.4 Test Manager ...................................................... 34316.5 Performance Manager ........................................ 34416.6 Fault Manager ..................................................... 34516.7 Analogue Value ................................................... 34616.8 Security Manager ................................................ 346
SECTION IX Troubleshooting ......................... 347
1.0 General ........................................................................ 348
2.0 Description of Alarm LEDs ......................................... 3482.1 IDU Alarm LEDs .................................................. 3482.2 HSB-IDU Alarm LEDs and Switch Indicators ..... 3482.3 LEDs on Line Interface Plug-in Boards ............... 349
3.0 Troubleshooting by NEW-NMS Configurator .......... 3493.1 Introduction.......................................................... 3493.2 Information Acquisition ........................................ 3493.2.1 Polling ................................................................. 3493.2.2 Event Notification ................................................ 3503.3 Alarm Presentation.............................................. 3503.4 Visual Alarm Notification ...................................... 3513.4.1 Alarms on a Tree node/leaf in the Explorer view . 3513.4.2 Alarms on a Node symbol in the Map view .......... 3523.4.3 Viewing Alarms in the Current Alarms View ........ 353
SECTION X Appendices................................... 355
Appendix I: IDU / HSB-IDU Interface Description.................. 356
Appendix II: ODU Interface Description ................................. 370
Appendix III: Alarm List & Alarm Description .......................... 371
B4008 Rev. M 21
Equipment Description
EquipmentDescription
SECTION I
22 B4008 Rev. M
CityLink
1.0 IntroductionCityLink is a super compact SDH radio-relay transmission system with STM-1 capacity. The equipment is split mounted with one single coaxial cablebetween the InDoor Unit (IDU) and the OutDoor Unit (ODU). The ODU andantenna can be located up to 300 meter apart from the IDU. The equipmentis available in 1+0 (single), 2+0 or 1+1 hot standby configurations. Variousline and tributary interface options are available as plug-in modules. Theequipment is also prepared for 21x2Mbit/s terminal multiplexer functionality.
The network applications foreseen for this equipment are mainly for in-creased connectivity in urban area as well as closure of fiber optic rings.Additionally, in the fixed part of mobile networks, this equipment issuitable.
Built-in supervision enables easy installation and configuration, and sys-tem status and availability data may be recorded. Advanced managementwith standardized use of the Embedded Control Channel (ECC) allows foreasy access to this equipment. Broadband RF design enables easy channelselection.
B4008 Rev. M 23
Equipment Description
Key features• Easy installation• Frequency agility• 155 Mb/s Line interface plug-ins available:
Unbalanced 75Ω coaxialBalanced, Category 5 UTP, 100 ΩSingle Mode fiber opticMulti Mode fiber optic
• SW managed configuration of 32, 64 and 128 TCM modulation• SW managed configuration of STM-0 or STM-1 capacity• 21x2Mbits/s terminal multiplexer option• 3xDS3/E3 and DS1 option• ADM STM-1 option (STM-1 cross-connect)• Fast ethernet radio option• 64kbit/s and 2Mbit/s insert channels• Service Channel / Engineering Orderwire• Line extensions (2) for Service Channel• Built-in diagnostics with local and remote loopback• Available Configurations:
1+0 (Unprotected) (STM-1 & STM-0)1+1 (Hot Standby) (STM-1 & STM-0)2+0 Dual frequency, Single Polarisation (DF-SP) (2xSTM-1 & STM-0)2+0 Single frequency, Dual Polarisation (SF-DP) (2xSTM-1 & STM-0)
• High system gain• Automatic/Manual Transmitter Power Control (ATPC/MTPC)• Standardized use of the ECC• Embedded SNMP (Option)• 14, 28, 50 & 55 (56) MHz channel arrangements• 2MHz synchronization interfaces (SETS)• Interface for local and subnetwork management (LAN or RS-232)
24 B4008 Rev. M
CityLink
2.0 IDU2.1 IDU Description
Figures X-1 shows the IDU front layout. All the connectors are located onthe front for easy operation. In addition to the line interface, 2Mbit/swayside and 64kbit/s data channels are available. As options, a 21x2 Mbit/s terminal multiplexer, ADM STM-1 (X-Connect) or DS3/E3 can be config-ured by adding a second circuit board. The IDU is equipped with anintegrated supervisory system for local and remote configuration andcontrol. The supervisory system communicates with the ODU by use of anFSK modulated channel on the coaxial cable. The same coaxial cable alsocarries power to the ODU. For configuration and management purposes theIDU is equipped with two LCT interfaces for connection to the PC, one withRS-232 interface and one LAN TP interface. In addition NI interfaces forconnection to other IDUs or other Nera equipment are provided. A SETSfunction is incorporated into the unit, conforming to ITU-T rec. G.823 withbalanced 120Ω interface. The IDU has a connector for alarm input/outputfunctionality (ALM/AUX). Alarm and warning LEDs are located on righthand side of front. Located close to the power connector is a power indicatingLED.
Figure I-1 shows a block schematic view of the IDU with various optional lineinterface plug-in boards and also a 21x2 Mbit/s Extension Board. In radiotransmit direction, the 155 Mb/s input signal from the line interface board isfed to the “SORP” ASIC. It performs all the SOH processing and radioscrambling. Then, the TX FPGA encodes the signal by use of a convolutioncode and an optional Reed Solomom code. The signal is then mapped intoa “32TCM”, “64TCM” or “128TCM” constellation, as required. It alsoperforms the necessary pulse shaping by use of a digital FIR-filter. The signalis then digitally I-Q modulated, and the 350MHz IF signal is fed to the ODUinterface and applied to the IF coaxial connector. In receive direction the140MHz IF from the ODU will interface the IDU on the same connector. Thenecessary cable equalizing functions are provided in the ODU interface andthe equalized IF is presented to the coherent demodulator. From the demod-ulator the signal is fed to the RX FPGA, which perform slope equalization andreceive filtering. Then the “ATDEC” ASIC, performs Trellis decoding, by useof soft decision and the “Viterbi” algorithm for error correction. The optionalReed Solomon decoding is performed in the RX FPGA. The decoded signalis then fed to the SORP ASIC for radio descrambling and SOH processing,and is finally fed to the line interface board.
B4008 Rev. M 25
Equipment Description
Figure I-1 Block schematic view of the IDU
File
: ID
U-H
RQ
I.DSF
LAN
(10B
ASE-
T)
2 x
NI
48V
DC
2Mb/
s W
AYSI
DE
MO
DEM
TR
ANSC
EIVE
R C
OM
MU
NIC
ATIO
N
DC
C
REG
ULA
TED
OU
TPU
TS
ASIC
DC
/ DC
TRIB
UTA
RY
INTE
RFA
CE
BLO
CK
NO
. 2
FPG
A
21x2
Mb/
s LI
NE
INTF
C./A
DD
-DR
OP
EXT
EN
SIO
N B
D.
MAI
N B
D.
TX:
FPG
A
MAP
PER
ENC
OD
ER
FILT
ER
"SO
RP"
STM
-1O
VER
HEA
DAN
DR
ADIO
PRO
CES
SOR
2MH
z SY
NC
OD
U
2 x
64 K
b/s
ALAR
MS
LCT
V11/
G.7
03
INTE
RFA
CE
INTE
RPO
LATI
ON
MO
DU
LATI
ON
UPC
ON
VER
SIO
N
OD
UIN
TER
FAC
E
1 21
21x2
Mb/
sG
.703
G.7
03
ALM
/AU
XIN
TFC
.
155
Mb/
sLI
NE
INTE
RFA
CE
Opt
ical
MM
F ~2
Km
or E
lect
r. C
AT5
UTP
or E
lect
r. G
.703
TRIB
UTA
RY
DAT
AM
APPE
RN
O. 1
TRIB
UTA
RY
DAT
AM
APPE
RN
O. 1
ASIC
's
SU
PER
-V
ISO
RY
SYS
TEM
FIFO
BU
S
ASIC
"ATD
EC"
TREL
LIS
DEC
OD
ER
HSB
IDU
INTF
C.
SVC
EPH
ON
EIN
TER
FAC
E
PHO
NE
2 x
PHO
NE
EXT.
"E1"
"H2"
SYN
C.
INTE
RFA
CE
D/A
CO
NVE
RSI
ON
DO
WN
CO
NVE
RSI
ON
A/D
CO
NVE
RSI
ON
RX:
FPG
A
CAR
RIE
R R
EC.
DEM
APPE
RC
LOC
K R
EC
.
DEC
OD
ER
OSC
.SO
UR
CE
OSC
.SO
UR
CE
4x 3x87
.5 M
Hz
93.3
MH
z
2x
or O
ptic
al S
MF
~40K
mor
Opt
ical
SM
F ~1
5Km
or O
ptic
al S
MF
~80K
m
26 B4008 Rev. M
CityLink
2.2 Hot Standby IDU DescriptionFigure X-2 shows the HSB IDU front layout. The connectors on the frontare identical to the ones used on the IDU and is therefore not furtherdescribed here. Additionally, a second power connector is added forpower redundancy enabling separate battery courses. Figure I-2 shows ablock schematic view of the IDU with various optional line interface plug-in boards. Interconnection of data and control signals between IDUs (A andB) and HSB IDU is by means of a connector and special split cable. Thiscable is part of the HSB cable kit. In a 1+1 HSB system, all the customerinterfaces are towards the HSB IDU. These signals are disabled on the IDUin such a configuration. The same alarm and warning LEDs used on IDU isalso used here. Additionally, a second power indicating LED is locatedclose to the redundant power connector. Also, an array of four LEDs,located on the right hand side in close proximity to the alarm/warningLEDs, indicates switching status in transmit and receive direction.
B4008 Rev. M 27
Equipment Description
Figure I-2 Block schematic view of the HSB IDU(shown here with DS3/E3 Extension Board)
File: HSBIDU-HRQE.DRW
LAN (10BASE-T)
2 x NI
48V DC
2Mb/s WAYSIDEDCC
REGULATEDOUTPUTS
ASIC
DC / DC
TRIBUTARYINTERFACE
BLOCK
FPGA
3xE3/DS3 EXTENSION BD.
MAIN BD HSB IDU.
"SORP"SDH
OVERHEADAND
RADIOPROCESSOR
SYNC.2MHz SYNC
2 x 64 Kb/s
ALARMS
LCT
V11/G.703
INTERFACE
3x34/45 Mb/s
G.703INTERFACE
ALM/AUXINTFC.
155 Mb/sLINE
INTERFACE
TRIBUTARYDATA
MAPPERNO. 1
TRIBUTARYDATA
MAPPERNO. 1
ASIC's
SUPER-VISORYSYSTEM
FIFO BUS
IDU A INTFC. (R)
SVCEPHONE
INTERFACE
PHONE2 x PHONE EXT.
"E1"
"H1"
IDU B INTFC. (P)
Optical MMF ~2Km
or Electr. CAT5 UTPor Electr. G.703
or Optical SMF ~40Kmor Optical SMF ~15Km
or Optical SMF ~80Km
G.703
1.5 Mb/s WAYSIDE PHY
28 B4008 Rev. M
CityLink
2.3 Line Interface BoardsSix different versions of 155 Mb/s line interface boards are presentlyavailable as plug-in modules. These are:
• Electrical, 75Ω unbalanced interface bd. according toITU-T rec. G.703.
• CAT-5 UTP electrical interface bd. according toATM Forum rec. af-phy-0015.000.
• Multimode Fiber optical interface bd. according toANSI rec. T1.646 and T1.105.06 type “SR-0”.
• Singelmode Fiber optical interface bd. according toITU-T rec. G.957, type “S-1.1”.
• Singelmode Fiber optical interface bd. according toITU-T rec. G.957, type “L-1.1”.
• Singelmode Fiber optical interface bd. according toITU-T rec. G.957, type “L-1.2”.
In a 1+1 HSB system, the line interface board will only be used on the HSBIDU. All the interface boards have an input signal indicating LED.
2.4 Service TelephoneA service telephone with collective call is provided in both the IDU andHSB IDU. In a 1+1 HSB system, the customer interface connection mustbe towards the HSB IDU.
External connection to two other similar equipment can take place via twoRJ-45 ports on the front. Refer to Appendix I for connector pin-out anddescription and Figure I-3 for circuit diagram of the service channelinterface. The balanced interfaces have a nominal level of -6dBm and600Ω impedance. Connect OUT to INP and vice versa.
Service channel signalling is based on collective call. The DTMF-starsequence is used as collective call to interface with other Nera equipment.
If other equipment connected have a different calling system than DTMF-star, they may use CALL INP/CALL OUT. Station ground connected toCALL INP will start transmission of DTMF-star as well as activating abuzzer. A detected DTMF-star will activate the CALL OUT by opening anoptocoupler to station ground.
For Nera PDH-radio equipped with Service Board 2NF467A, CALL INPhas to be connected to CALL OUT and vice versa.
B4008 Rev. M 29
Equipment Description
Figure I-3 “Service Channel CALL" Circuit Diagram
CALL_OUT/CTRL_OUT
CALL_INP/CTRL_INP
2BAS1
6
31
2110k
1 BSR19APC3Q66Q1
2BYM12232
1k2 1
16 1
3
15 2 BSR19A1
1 3 14
1kPC3Q66Q
24 13 -48V
21 +3.3V10k
CTRLINPCALLINP/
212 CTRLOUT10kCALLOUT/
+5V
A control signal can be transferred over the radio hop. Station groundconnected to CTRL INP will set a signalling bit which is detected on theother side and activates CTRL OUT by opening an optocoupler to stationground. See Figure I-3. The control signal is used to control PABX-adapters and to switch off loudspeakers on Nera service boards withselective call (e.g. 2NF4688, 2NF533B and 2KNF232A). The controlsignal is transferred only if SOH-byte “E1”, “E2” or “F1” is used fortransmission of service channel.
For setup by NEW, refer to Section VII.
30 B4008 Rev. M
CityLink
2.5 21x2Mbit/s Extension Board (option)In Figure I-4, a block schematic depiction of a 21x2Mbit/s Extension Boardfunction are given. This function enables twenty-one 2Mbit/s channels tobe multiplexed/demultiplexed, enabling a terminal multiplex function. It ispossible to configure the unit to drop a certain number of 2Mbit/s channelswhile delivering the rest as a part of the STM-1 payload in a “drop-and-continue” configuration. In a standard terminal multiplexer configuration,the plug-in line interface board is omitted. The 2Mbit/s channels conform toITU-T rec. G.703, balanced 120Ω. Also provided on the same circuit boardis the option of using one of the 2Mbit/s channels as SETS reference clockinput/output, according to ITU-T rec. G.823.
In a 1+1 HSB system, this interface board will be mounted in the HSB IDU.In a 1+0 system it will be included in the IDU.
TRIBUTARYINTERFACE
BLOCKNO. 1
ASIC
21x2 Mb/s LINE INTFC./ADD-DROP EXTENSION BD.
1
21
21x2 Mb/sG.703
TRIBUTARYDATA
MAPPERNO. 1
TRIBUTARYDATA
MAPPERNO. 1
ASIC's
To/fromtheIDU'sSDH Overhead and Radio Processor(SORP)
Figure I-4 Block schematic view of the 21x2Mbit/s Extension Board
2.6 ADM STM-1 (X-Connect) Extension Board (option)The Extension Bd. ADM STM-1, which is a part of the Indoor unit in theNERA CityLink, is an optional ITU-T standard STM-1 interface implementedfor 155 Mbit/s signal entry and exit in a ring topology. The STM-1 entry signalinto the ring is split and transmitted to line and radio side in parallel. Signalsexiting the ring are received from line and radio side. These are up to 63xVC-12s from either side and they are protected, i.e. they shall be switchedindividually if a break somewhere in the ring occurs. Also, the system willhandle any allowed combination of VC-3s and VC-12s.
In Figure I-5, a block schematic of the STM-1 Extension Board functions isshown. The STM-1Extension Board will interface one STM-1 line signal inTx- and Rx-direction. The STM-1 interface is interchangeable in the following
B4008 Rev. M 31
Equipment Description
Figure I-5 Block schematic view of the ADM STM-1 Extension Board
TDM1RADIO
TDM1LINE
TDM1LINE
EXTENSIONBOARD
PLD14FPGA
SORPEXT BOARD
LINEINTERFACE
CARD
IDU CONN
way: In a slot in the STM-1Extension Board, a line interface board is inserted.Presently one type of board is implemented: The plug-in board compliantwith ITU-T G.703 CMI encoded 155 Mbit/s customer interface; 2LN24C. Agreen LED, located on the front of the board indicates presence of an inputsignal. The line interface board is mounted on the extension board prior tothis being mounted within the IDU cabinet. This means that the line interfaceboard will not be used as a plug-in type board in this application.
SOH processing and line scrambling /descrambling on the STM-1 interfaceare performed by the SORP ASIC. The TDM1 ASICs perform insertion,extraction, signal processing and cross-connection of data in the payloadof the STM-1 frame and also make error and performance measurements onVC-3 and error measurements on VC-12. The PLD14 FPGA makes perform-ance measurements on VC-12s embedded in the STM-1 datastreams fromtwo TDM1 ASICs. The measurement results are used to choose individualVC-12s from the two datastreams in TDM1 ASIC no.1 and TDM1 ASIC no.2.The selection is done by the SU in TDM1 ASIC no. 3. See Figure I-5.
TDM1 ASIC no 1——→PLD14 FPGA———————→TDM1 ASIC no 3 ————————→
TDM1 ASIC no 2 ————————-→
SORP ASIC no 2 —————————→
Line Interface Board ———————-→
32 B4008 Rev. M
CityLink
2.6 3xDS3/E3 and DS1 Extension Board (option)DS3 is a 45Mbit/s PDH standard used for the North American marked, E3 is34Mb/s PDH standard used for the European marked and the DS1 is a1.5Mbit/s PDH standard used for the North American marked. The 3xDS3/E3 and DS1 Ext. Bd., which is a part of the Indoor unit in the NERA CityLink,will perform add-drop of 3xDS3/E3 PDH channels to-from a STM-1 frame. Inadditional it will perform insertion and extraction of 1.5 Mbit/s wayside (DS1/T1).
In Figure I-6, a block schematic of the 3xDS3/E3 and DS1 Ext. Bd. functionsare shown. The 3xDS3/E3 and DS1 Ext. Bd. will interface three DS3/E3 andone DS1 line signal in Tx- and Rx-direction. The line interface circuit includes;cable equalizer, line coding and pulse shaping functions. This is performedby two Line Interface Unites (LIU), one for DS3/E3 an one for DS1. SOHoverhead and radio processor is located oh the motherboard in the IDU.
The PLD15 FPGA maps the 3xDS3/E3 into three VC3s, then into a VC4 andthen into a STM-1 signal and de-maps in the opposite direction. The STM-1 signal is locked to a 2.048 MHz input (SETS) coming from the motherboard.The TDM1 ASIC performs insertion, extraction and cross-connection ofdata in the payload of the STM-1 frame. Together, the two TDM1s and PLD15implement the core of a DS3/E3 add-drop multiplexer. The 1.5 Mbit/sWayside (DS1/T1) function is implemented in PLD15 and is independent ofthe TDM1 ASICs.
Figure I-6 Block schematic view of the 3xDS3/E3 Extension Board
3xDS3/E3 and T1 EXT. BOARD
48 V
+3.3 V +1.5 V
TDM1 No. 1 LINE
TDM1 No. 2 RADIO
3xDS3/E3
DC/DC
T1 LIU
PLD15
IDU CONNECTOR
B4008 Rev. M 33
Equipment Description
2.6 Ethernet Extension Board (CityLink Fast Ethernet)In Figure I-7, a block schematic description of an Ethernet Extension Board(EEB) is given. This function enables 4 separate Ethernet channels 10BASE-T/100BASE-TX and 4 separate 2Mbit channels conforming to ITU-T rec.G.703. The EEB will treat all 8 channels separately, meaning that all dataentering on one channel will leave on the same channel on the other side ofthe radio hop. All channels are full duplex. The four Ethernet and four 2Mbit/s channels shares the STM-1 data capacity. The 2Mbit channels, if enabled,will always be guaranteed full bandwidth. The 4 Ethernet channels can beconfigured to either equally share the STM-1 data frame, or one channel canbe given priority. The EEB has a limited on board Ethernet package buffercapacity. This gives the ability to handle short time 100Mbit/s bursts on allfour channels without package loss. Also the EEB supports flow control,making it possible to configure a 400Mbit full duplex network withoutpackage loss, even though the radio hop is limited to STM-1 data rate.
To from IDUmain board
4x RJ45Ethernet
4x RJ452Mbit
Ethernet to/fromSTM1 and 2Mbitmapper/demapper
EthernetInterface
2/1.5MbitInterface
Figure I-7 Block schematic view of the Ethernet Extension Board
2 Mbit/sInterface
Ethernet to/fromSTM1 and 2Mbit/smapper/demapper
34 B4008 Rev. M
CityLink
3.0 ODU3.1 ODU Type I Description
The ODU Type I is an assembly of branching unit and transceiver unitmounted behind the antenna or on a mounting frame on a pole/column. TheODU is connected to the IDU with a single coaxial cable. The coaxial cableprovides Tx-IF, Rx-IF, signalling and power supply. For flexibility and easy
installation, the coaxial cable is con-nected to the transceiver through thebranching unit. The transceiver is at-tached to the branching with a snap onsystem. With this solution, the coaxialcable may remain connected duringtransceiver replacement. In 1+0 con-figuration the branching unit is for asingle transceiver and in Hot Standbyconfigurations the branching is for dualtransceivers. The ODU and the antennaare assembled very closely togethermaking it very compact. Neverthelessthe antenna can be separated from theODU by use of a flexible waveguide.
The branching unit contains RF channel filters, circulators and overvoltageprotection. The Hot Standby branching contains in addition a RF switch fortransmit direction and a RF power splitter for the receive direction.
The transceiver unit contains a microwave Tx/Rx module, a synthesisedlocal oscillator and a transceiver main board, all in a waterproof housing.The transceiver is based on dual frequency conversion in the transmitterand triple conversion in the receiver. This radio architecture with high IFfrequencies allows for use of wide band branching filters while stillmaintaining excellent spectrum purity in transmitter and high selectivityin receiver. The use of wide band branching filters allows for a wide choiceof remote channel frequency selection without changing hardware.
The microwave module is an integrated multi-chip module with GaAsHEMT MMICs for Power Amplifier and Low Noise Amplifier. Thenecessary LO frequencies for the frequency converters are generated ina low phase noise synthesiser unit. The channel frequency is remotelyprogrammed from the indoor unit. Transmit/receive IF-chain, control-circuits, signalling and power supply are integrated on the transceiver mainboard.
B4008 Rev. M 35
Equipment Description
Figure I-8 Block schematic view of the ODU Type I, 18GHz, in 1+0 configuration
TRA
NSC
EIVE
R U
NIT
140
MHz
350
MH
z
IF IN
/ O
UT
M /
T C
OM
DC
PW
R
BR
AN
CHIN
GU
NIT
TRA
NSC
EIVE
R M
AIN
BO
AR
DM
ICR
OW
AVE
MO
DU
LE
XN
AN
TEN
NA
UN
IT
PWR
SYN
THES
IZER
DUP
LEX
FREQ 7
GH
zFI
XED
21
0 M
Hz
PRE-
DIS
T
2 G
Hz
SYN
TH
UHF
LO
CAB
.EQ
.
IF IN /
OU
T
UHF
LO
CTR
L / M
/T C
OM
/ PO
WER
IF L
OO
P
350
MH
z
UH
FIF
350
MH
z
36 B4008 Rev. M
CityLink
3.2 ODU Type II DescriptionThe Type II of the ODU consists of a weatherproofbox containing the branching system. The ODUbox is mounted on a pole/column behind the anten-na. The Transceiver unit is a plug-in unit mounted inthe box. In 1+0 configuration the ODU box con-tains a 1+0 branching unit for a single transceiverand in Hot Standby configurations the ODU boxcontains a Hot Standby branching unit and dualtransceivers. The branching unit contains RF chan-nel filters and the diplexer. The Hot Standby branch-ing contains in addition an RF switch for transmitdirection and an RF power splitter for the receivedirection.
The transceiver unit contains 7 modules/sub-units;a microwave transmitter module, a receiver mod-ule, 3 local oscillators, an IF &controller board and a detector board. Thetransceiver is connected to the modem/IDU with a single coaxial cable thatcarries Tx-IF, Rx-IF and signalling (MTcom). Power is supplied througha separate connector (D-sub), and for the split mount case this power isseparated from the coaxial cable in the ODU container (box).
The transceiver utilises a single conversion scheme in the transmitter anda dual conversion in the receiver. In order to obtain an optimum spectrummask, the transmitter chain contains predistortion circuitry at IF beforethe microwave upconverter and power amplifier. Narrow channel filters inthe branching unit further reduces the spectrum mask. The second convert-er in the receive chain allows for an IF loop-back facility for diagnosticspurposes. LO frequencies for the microwave frequency converters aregenerated in synthesised DROs. The oscillators are by nature fixed infrequency, i.e. they can only be remotely programmed within a narrowrange. When necessary, the oscillators can be adjusted within a range ofapprox. 200 MHz with a mechanical screw (see Section VII Chapter4.5.2.3 for guidance). Power supply, transmit/receive IF-chain, signallingand controller (DSP) for the transceiver are integrated on the IF &control-ler board.
The branching unit contains narrow RF channel filters and circulators.
B4008 Rev. M 37
Equipment Description
Mul
ti-pl
exer
AG
C &
Cab
leeq
ualiz
erPr
edis
tort
ion
&A
GC
SSB
Upc
onve
rter
Pow
erA
mpl
ifier
LO, I
MD
mxr
Low
Noi
seA
mpl
ifier
IMR
Mix
erFL
TR &
AG
CD
SBM
ixer
FLTR
&A
GC
MT-
Com
.C
TRL
IMD
Det
.LO D
et.
DC
/DC
Tx IF
35
0 M
Hz
Rx
IF
140
MH
z
MTc
om 48V
350
MH
z
140
MH
z
Tx-
Syn
t.
Rx-
Syn
t.
IF-
Syn
t.
350
MH
z
Synt
hesi
zer U
nit
XMTR
Mod
ule
RC
VR M
odul
e
140
MH
z
210
MH
z
Tx L
O
Rx
LO
350
MH
z
IF lo
op
IF&
CTR
L B
d.
RF
out
RF
in
Figure I-9 Block schematic view of the ODU Type II, 7GHz, in 1+0 configuration
38 B4008 Rev. M
CityLink
3.3 ODU Type III DescriptionType III of the ODU consists of a singleODU (in 1+0 configuration) mountedbehind the antenna and attached to theantenna by means of four snap-onclamps. The ODU is connected to theIDU via a single coaxial cable whichcarries transmitter IF, receive IF andcontrol and monitoring signals, as wellas DC power. In 2+0 and 1+1 hot stand-by configurations both ODUs are at-tached by the same snap-on clamps to abranching hybrid. This hybrid can ei-ther be bolted directly to the antenna orvia a short length of flexible waveguide.The branching hybrid contains an RFsplitter and combiner.
The ODU consists of a weatherproof housing containing a microwavetransmit/receive module, a synthesised local oscillator module and an IFand control transceiver main board. The transceiver is based on a dual up-conversion and triple down-conversion scheme, which allows the use ofwide-band duplex filters and therefore a wide choice of remote channelfrequency selection. To optimise the transmitter spectrum the transmitteremploys pre-distortion at IF as well as cable equalisation to correct forvariable loss and slope in the cable.
The microwave transmit/receive module consists of a multi-chip moduleusing a set of GaAs HEMT MMICs, both for the transmitter poweramplifier and the low-noise receiver. The required local oscillator signalsare fed from the synthesised local oscillator module and up-convertedusing a diode multiplier. The channel frequency is remotely selected viathe IDU. Transmit/receive IF multiplexing, control and monitoring andpower supply functions are all integrated on the transceiver main board.
B4008 Rev. M 39
Equipment Description
MA
IN B
OA
RD
MIC
RO
WA
VE C
ON
VER
TER
210M
Hz
7-9
GH
zSY
NTH
EZIS
ER
TRA
NSC
EIVE
RA
NTE
NN
A
DIP
LEXE
RD
IPLE
XER
DU
PLEX
FREQ
.
UH
F LO
1 (L
O2) U
HF
LO2
(LO
1)
PRE-
DIS
T
SLO
PE
EQU
ALI
SER
Figure I-10 Block schematic view of the ODU Type III
40 B4008 Rev. M
CityLink
4.0 ManagementAn integrated supervision system makes the CityLink capable of function-ing as a Network Element (NE) in a managed SDH transmission network.Management and supervision of the CityLink can be performed in variousways from very simple alarm monitoring to standardised managementthrough optional built-in NE agents. Standardised use of QECC, accordingto ITU-T Rec. G.784, is provided.
As an option, the CityLink also supports embedded SNMP agent that canbe controlled by SNMP based manager supplied by the service provider.
For element and network management the NEW-NMS (Nera Element vieW- Network Management System) software provides the full range of manage-ment functionality; Fault, Performance, Security and Configuration.
The integrated SNMP agent provides interface to higher level NetworkManagement Systems.
The alternative interfaces available at the IDU are described in AppendixI; IDU Interface Description.
5.0 System ConfigurationsCityLink is available in the following configurations:
Frequency Band L6 – 11 GHz 13 – 15 GHz 18 – 23 GHz 26 – 38 GHz
1+0 (Unprotected) OK
1+1 (Hot Standby) OK
1+1 Frequency Diversity OK NA
1+1 (Hot Standby) – Dual Baseband OK OK OK NA
1+1 (Hot Standby) – Dual antenna TBD TBD TBD OK
2+0 Dual frequency – Single polarisation (DF-SP)
OK
2+0 Single frequency – Dual Polarisation (SF-DP)
NA NA 32 TCM only 32 TCM only 1
2+0 Alternating Polarisation (AP) OK 1
1+0 prepared for 2+0 OK
Table I-1 System Configurations
B4008 Rev. M 41
Equipment Description
155 Mb/s
SDH/SONETProcessing
STM-1/OC-3Plug-inLine Interface
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Indoor unit (IDU)
Management&
SNMP Agent
Antenna
Transceiver
Branching
Auxtraffic
Management
OptionalPlug-in
Multiplex Unit
Coaxial cable(up to 300 m)
Figure I-11 1+0 System Overview
5.1 1+0ConfigurationThis system consists of one indoor unit and one outdoor unit interconnectedwith a single coaxial cable.
Figure1-11 shows a 1+0 system overview. Each of the shaded area representsa function or unit. The IDU is a single unit with plug-in STM-1 line interfaceand the optional Multiplexer Unit. The ODU is assembled by transceiver andbranching.
Space Diversity and Hybrid Space Diversity is available as specified in thetable below.
Frequency Band L6 – 11 GHz 13 – 15 GHz 18 – 23 GHz 26 – 38 GHz
Space Diversity with IF combining 1+0,1+1 FD, HSB
OK NA NA NA
Hybrid Space Diversity (HSB) OK NA NA NA
Hybrid Space Diversity (1+1 FD) OK OK OK NA
Table I-2 Space Diversity Configurations
42 B4008 Rev. M
CityLink
5.2 Hot Standby ConfigurationIn Hot Standby configuration the IDU, the transceiver unit, and the coaxialcable between IDU and ODU are duplicated. The two transceivers share thesame branching unit/hybrid. A switch at radio frequency level, included inthe branching unit 1, allows for switching between the two transmitters. ASwitching Unit is placed between the two IDUs and performs hitlessswitching in the receive direction. The STM-1 line interface and Multiplexplug-in modules are mounted in this switching unit. Signal interconnectionbetween the IDUs and the switching unit is by a multi connector and a splitcable.
1) Some ODU types use a passive combiner/splitter at RF level.
Indoor unit (IDU)
Outdoor unit (ODU)
Coaxial cable(up to 300 m)
Antenna unit
SDH/SONETProcessing
STM-1/OC-3 Plug-inLine Interface
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management
TransceiverUnit
BranchingUnit
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management
TransceiverUnit
Optionalplug-in
Multiplex UnitAuxtraffic
Management Management
&SNMP Agent
SDH/SONET Processing
155Mbit/s
Figure I-12 1+1 Frequency Diversity and Hot Standby System Overview
5.3 1+1 Frequency DiversityA 1+1 Frequency Diversity system contains duplicated IDU and ODU anda 1+1 FD branching. (Dual polarised branching can also be used.). Aswitching Unit is placed between the two IDUs and performs hitlessswitching in the receive direction. The interface units are mounted in theswitching unit. Signal interconnection between the IDUs and the switchingunit is by a multi connector and a split cable.
B4008 Rev. M 43
Equipment Description
5.4 Hot Standby Configuration – Dual AntennaThe Hot Standby configuration is for 26-38 GHz also available with duplicat-ed antenna. There is no Tx-switch at radio frequency level and the standbytransmitter is muted. Both receivers are active and selection of receive signalis performed by the IDU-switch. This configuration gives better system gainas no HSB-hybrid loss is added.
Indoor unit (IDU)
Outdoor unit (ODU)
Coaxial cable(up to 300 m)
Antenna unit
SDH/SONETProcessing
STM-1/OC-3 Plug-inLine Interface
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management TransceiverUnit
BranchingUnit
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management
Optionalplug-in
Multiplex UnitAuxtraffic
Management Management
&SNMP Agent
SDH/SONET Processing
155Mbit/s
BranchingUnit
TransceiverUnit
Antenna unit
Figure I-13 Hot Standby-Dual Antenna System Overview
44 B4008 Rev. M
CityLink
5.5 Hot Standby Configuration – Dual BasebandA special variant of the Hot Standby system is the Dual baseband option.In this configuration both IDUs are equipped with STM-1 line interface units.The switching unit is not used in this configuration. The feature enables lineprotection when used with muxes with dual/protected interfaces
Outdoor unit (ODU)
Coaxial cable(up to 300 m)
Antenna unit
TransceiverUnit
BranchingUnit
TransceiverUnit
155 Mb/s
SDH/SONETProcessing
STM-1/OC-3Plug-inLine Interface
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management&
SNMP Agent
Auxtraffic
Management
155 Mb/s
SDH/SONETProcessing
STM-1/OC-3Plug-inLine Interface
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Indoor unit (IDU)
Management&
SNMP Agent
Auxtraffic
Management
Figure I-14 Hot Standby-Dual Baseband System Overview
B4008 Rev. M 45
Equipment Description
5.6 2+0 ConfigurationThe 2+0 system can be used in two types of configuration, using one or twopolarisations. Single Frequency – Dual Polarisation (SF-DP) and AlternatingPolarisation (AP) utilise both polarisations in order to double the capacity.Dual Frequency – Single Polarisation (DF-SP) requires two channels in orderto transmit 2xSTM-1. With this configuration, adjacent channels cannot beused. Figure I-15 and Figure I-16 show block diagrams of the 2+0 configu-rations.
155 Mb/s
SDH/SONETProcessing
STM-1/OC-3Plug-inLine Interface
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Indoor unit (IDU)
Management&
SNMP Agent
SDH/SONETProcessing
STM-1/OC-3 Plug-inLine Interface
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Indoor unit (IDU)
Management&
SNMP Agent
Outdoor unit (ODU)
Coaxial cable(up to 300 m)
Antenna
Transceiver
Branching
Auxtraffic
Management
Auxtraffic
Management
OptionalPlug-in
Multiplex Unit
OptionalPlug-in
Multiplex Unit
Transceiver
Branching
Coaxial cable(up to 300 m)
H-pol
V-pol155 Mb/s
Figure I-15 Single Frequency - Dual Polarisation / AlternatingPolarisation
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Indoor unit (IDU)
Management&
SNMP Agent
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Indoor unit (IDU)
Management&
SNMP Agent
Outdoor unit (ODU)
Coaxial cable(up to 300 m)
Antenna
Transceiver
Branching
Transceiver
Auxtraffic
Management
Auxtraffic
Management
OptionalPlug-in
Multiplex Unit
OptionalPlug-in
Multiplex Unit
STM-1/OC-3Plug-inLine Interface
STM-1/OC-3Plug-inLine Interface
155 Mb/s
155 Mb/s
Figure I-16 Dual Frequency - Single Polarisation
46 B4008 Rev. M
CityLink
5.7 Space DiversitySpace diversity with IF combining is available in the frequencies from L6 to11GHz. It can be used in combination with all other configurations. The figurebelow shows a 1+1 Frequency Diversity or HSB system.
Outdoor unit (ODU)
MainAntenna
Main Branching
SDAntenna
SDTransceiver
SD Branching
SDTransceiver
Indoor unit (IDU)
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management
Coaxial cable(up to 300 m)
WG
STM-1/OC-3 Plug-inLine Interface
Optionalplug-in
Multiplex UnitAuxtraffic
Management Management
&SNMP Agent
SDH/SONET Processing
155Mbit/s
Figure I-17 Space Diversity
5.8 Hybrid Space DiversityHybrid Space Diversity using standard XCVRs without IF combining isavailable for 1+1 FD and HSB.In HSB configuration the splitter in the receiver branch is omitted and eachreceiver is connected to separate antennas. The transmitters are using themain antenna. Waveguide is needed from the ODU to the SD antenna. Theconfiguration is available for L6-11 GHz systems.
B4008 Rev. M 47
Equipment Description
Outdoor unit (ODU)
MainAntenna
Main Branching
SDAntenna
Transceiver
SD Branching
Transceiver
Indoor unit (IDU)
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management
SDH/SONETProcessing
Mod
ulat
orD
emod
ulat
or
DC
pow
er fe
edin
g&
over
volta
gepr
otec
tion
Management
Coaxial cable(up to 300 m)
WG
STM-1/OC-3 Plug-inLine Interface
Optionalplug-in
Multiplex UnitAuxtraffic
Management Management
&SNMP Agent
SDH/SONET Processing
155Mbit/s
In 1+1 system hybrid diversity is implemented by using two antennas at oneof the sites. At this site one channel is connected to each antenna. In principleit is two 1+0 ODU operating at differnet frequencies. At the other site normal1+1 FD system is used.
Figure I-18 HSB Hybrid Space Diversity
UserInterfaces
IDU
IDU
Switch
1+0ODU
1+0ODU
IDU
IDU
SwitchUserInterfaces1+1
ODU
f1
f2
Figure I-19 1+1 Hybrid Space Diversity
48 B4008 Rev. M
CityLink
This page is intentionally left blank.
5.9 Radio Terminal ConfigurationsThe radio channel can be configured with RS- or MS-termination accordingto ITU-T Rec.G.783.Figure 1-20 shows examples of various configurations. MST configurationrequires the optional SETS function.
RRT RRT RRTRRT
RS RS RS
MS MSMS
MS Other MSequipment
Other MSequipment
Figure I-20 Configuration Examples
5.10 Radio Repeater ConfigurationsA radio repeater is built by using two terminals. The interface between theterminals is at STM-1. The repeater can be configured with RS-terminationaccording to ITU-T Rec. G.783.
5.11 Radio Channel IdentificationThe radio channel is identified by two allocated bits in the media specific byte(MS#3) in the SOH. The channel identification can be configured by the user.
B4008 Rev. M 49
ODU Type I Installation
Installation ofODU Type I and Antenna
SECTION II
50 B4008 Rev. M
CityLink
1.0 GeneralThis section assumes that pre-planning of the link has been performed, i.e.path budgeting & survey to ensure good line-of sight between the two linkends.
1.1 PackingAny sensitive product, i.e. IDU and Printed Circuit Boards, are packed inspecial antistatic handling bags or boxes.
It is therefore essential that whenever unpacking or disassembling theequipment and or handling printed circuit boards etc., special precautionsto avoid ESD (Electro Static Discharge) should be taken, such as usingwrist grounding or corresponding protection.
The equipment is packed in sealed plastic bags which are equipped withrequired moisture protection.
All equipment is further packed in special designed cases prepared fortransportation.
Dimensions and weight of each case are specified in the "Packingspecifications" issued for the respective shipment.
1.2 MarkingMarking is done according to customers requirements. If such informa-tion is unavailable, the equipment is marked in the following way:
Customer addressContract No.Site Name (if known)Case No.
1.3 TransportationThe transport containers are prepared for shipment by air, truck, railwayand sea, suitable for handling by fork-lift trucks and slings.
The cargo must be kept dry during transport and storage.For sea-transport, deck-side shipment is not permitted and carrier-ownedcargo containers should be used.
B4008 Rev. M 51
ODU Type I Installation
1.4 Radio Equipment Inventory CheckLook for damage on the cases. Ensure that correct quantities of goods havearrived, according to the packing list in each package/unit.
Check also that the part description on the outside of each box corre-sponds to the components required for the installation, i.e. correct antennaand frequency, ODU frequency band and sub-band, IDU configuration.
Report any damages or missing items to Nera ASA by e-mail or fax. A shortdescription of damages, preferably including photographs, should be sentas soon as possible.
1.5 Preparation for InstallationComplete the required civil works. Transport all the equipment to site.Unpack the equipment and inspect for damage during transit to site andmake sure that the correct quantities of goods have arrived.
Units with static discharge protection should not be unpacked until theequipment installation takes place. Ensure you are grounded at a control-led ESD point before and during insertion, and during any subsequentunpacking of the unit.
1.6 Handling & StorageIt is recommended that components are stored and transported to theinstallation site in their original packing cases. If items are unpacked forstorage, they should be handled with care and protected during transpor-tation by similar protective materials.
The equipment is an electronic device which should be handled with care.It should be stored in dry, cool conditions, out of direct sunlight. Amoisture absorbing bag is taped inside the transportation unit to minimisecondensation during transportation. This is to be removed at installation.
No maintenance is required when stored according to particulars above.
To avoid damage to the sealing components and unwanted moist in theinterconnection interfaces, the transportation protection lids on the branch-ing and the transceiver must be kept on until mounting of waveguidecomponents and connection of the transceiver to the branching unit.
52 B4008 Rev. M
CityLink
2.0 Installation Equipment required2.1 Tools
The tools needed to install the equipment are listed in the following sub-chapters.
2.1.1 Tools for Antenna Installation• 2 pcs Combination Wrench 13 mm• 2 pcs Combination Wrench 16 mm• 2 pcs Combination Wrench 17 mm• 1 pc Torque Wrench 16 mm, 40 - 50 Nm
2.1.2 Tools for IDU- ODU Cable /Connector Mounting• 1 Hacksaw, fine-toothed• 1 Soldering Iron, 50-150W• Solder 36/37 RMA flux core• Cloth• 1 Knife• 1 Flat file, fine• 1 Wire brush• 1 Tape rule (or caliper)• 1 Heat gun, 1000W• 1 Cutting pliers
for hexagon coupling nut :• 1 Wrench 1/2" (13mm)• 1 Wrench 9/16" (15mm)• 1 Wrench 11/16" (18mm)• 1 Wrench 13/16" (21mm)
B4008 Rev. M 53
ODU Type I Installation
2.2 Equipment external to the Radio EquipmentIn addition to the necessary radio equipment & antenna the followingitems are needed:
• Coaxial cable between IDU and ODU. See Section V, chapter 5 foradvise on which cable to use.
• At least two N-type connectors suitable for termination of theselected coaxial cable.
• Suitable waveguide & flanges between antenna and branching unit ifremote mount option is used.
• Cable to ground the ODU.• Cable to ground the IDU.• Cable to power the IDU.• Cable to connect the PC, running the configuration & set-up program,
to the IDU.• Cable ties to secure cable runs.• Cables for user interfaces.
54 B4008 Rev. M
CityLink
3.0 ODU / Antenna Installation, 1+0 Equipment3.1 Installation of 0.6m and 0.45m Antenna
3.1.1 Preparing the Suspension for ODU Mounting
Bracket
Loosen this nut one turn.
Rotate the bracket 1800 byturning this bolt CW.
B4008 Rev. M 55
ODU Type I Installation
3.1.2 Mounting the Antenna to the SuspensionAll the described nuts and washers are included in the antenna assemblyand come attached to the antenna.
4ea M8 Nuts and washers
56 B4008 Rev. M
CityLink
3.1.3 Mounting the Branching Support Bracket
M8x25
BRANCHINGSUPPORTBRACKET
B4008 Rev. M 57
ODU Type I Installation
REAR TRAVERS
M8x25
M8x25
SUSPENSIONSUPPORTBRACKET
3.1.4 Mounting the Rear Travers
3.1.5 Mounting the Suspension Support Bracket
58 B4008 Rev. M
CityLink
FEED
3.1.6 Mounting the Bend on the Branching Unit
M3 STUDS,NUTS ANDWASHERS
O-RING
B4008 Rev. M 59
ODU Type I Installation
3.1.8 Attachment of the Sunshield Support
Grounding point.See Section V Chapter 5.0 Fig. V-8
3.1.7 Installation of the Branching Unit
M8 STUDS,NUTS ANDWASHERS
BRANCHINGUNIT
SUNSHIELDSUPPORT
M8x30SCREW,NUT ANDWASHERS
M8x30 SCREW,NUT ANDWASHERS
60 B4008 Rev. M
CityLink
3.1.9 Installation of the Flexible Waveguide
M3 STUDS,NUT ANDWASHERS
2 O-RINGS
M3 ALLENSCREWS,NUT ANDWASHERS
R220 FLEXIBLEWAVEGUIDE
O-RING
B4008 Rev. M 61
ODU Type I Installation
3.1.10 Installation of the Sunshield
SUNSHIELD
M4x16 SCREWS,NUTS ANDWASHERS
M6x25 SCREWS,NUTS, LARGE WASH-ERS AND WASHERS
M4 ALLEN SCREW(FOUND MOUNTEDON THE BRANCHINGUNIT)
(PLACING OFLARGE WASHER)
62 B4008 Rev. M
CityLink
U-BOLTS(ABZ5479 forcolumndiameterØ115mm,ABZ5480 forcolumndiameterØ75mm)
3.1.11 Mounting the Suspension/Antenna to a Column or a Wall3.1.11.1 Mounting the Suspension/Antenna to a Column by
using the U-bolts
M10 Nuts, washers and lockwashers, 4eaTorque: 25-30Nm
B4008 Rev. M 63
ODU Type I Installation
3.1.11.2 Mounting the Suspension/Antenna to a Column byusing the Clamps
CLAMPS, 2ea(ABZ5481)
M10 Nuts and washers, 4eaTorque: 35Nm
Column diameter:60-115mm
64 B4008 Rev. M
CityLink
M10 Expansionbolts (typedependant onthe nature of thewall
M10 Nuts and washers
3.1.11.3 Mounting the Suspension/Antenna to a Wall
B4008 Rev. M 65
ODU Type I Installation
3.1.12 Mounting the ODU to the Antenna AssemblyBefore mounting the ODU to the antenna assembly, it is necessary toremove the protection lid from the antenna feed. See below.
First remove the nuts usinga 5,5mm wrench.
Then remove the set screwsusing a 1,5 mm allen key.
Protection lid
66 B4008 Rev. M
CityLink
B4008 Rev. M 67
ODU Type I Installation
BRANCHINGSUPPORTBRACKET
CLAMP
3.1.13 Pole Mount3.1.13.1 Assembly of Branching Support Bracket
3.1.13.2 Installation of Branching Unit and Sun-shield
M8
M4
BRANCHING UNIT
SUN-SHIELD
M12 (Torque 19 NM)
Grounding point.See Section V Chapter 5.0 Fig. V-8
68 B4008 Rev. M
CityLink
105m
m ±
5
3.2 Installation of 1.2m AntennaThis chapter only descibes how to install the CityLink branching supportbracket and the branching unit. For further instructions please refer to thehandbook supplied with the antenna (H2602; Installation Procedure for1.2m Antenna).
For installation of the transceiver, see Chapter 3.1.7.
3.2.1 Assembly of Branching Support Bracket
BRANCHINGSUPPORTBRACKET
HORIZONTALGIRDER
VERTICALGIRDER
HORIZONTALGIRDER
BRANCHINGSUPPORTBRACKET
Make sure that the distance between the top of the branching supportbracket and the horizontal girder is 105mm ±5mm.
B4008 Rev. M 69
ODU Type I Installation
3.2.3 Installation of Branching Unit,Sun-shield and Flexible Waveguide
NOTE!Most antennas are delivered with a bimetallic shim. This MUST NOT bemounted for 18-26GHz equipment as the ODU, the flexible waveguideand the antenna all have aluminium waveguide connectors. Flexiblewaveguides for 13-15GHz have silver plated brass flanges and thebimetallic shim MUST be used (copper side facing flex-wg).
Mount gasket(s) between the antenna feed and the flexible waveguideand also gasket(s) between the flexible waveguide and the branchingunit. If the installation is placed in a very corrosive environment, furtherprotection can be achieved by adding silicon rubber.
M4 M8
BRANCHING UNITSUN-SHIELD
FLEXIBLEWAVEGUIDE
ANTENNAFEED
FLEXIBLEWAVEGUIDE
70 B4008 Rev. M
CityLink
4.0 ODU / Antenna Installation,Hot Standby Equipment and 2+0 Equipment
4.1 0.45m and 0.6m Antenna
4.1.1 Installation of Hot Standby (HSB) and2+0 Dual Frequency Single Polarization Equipment
4.1.1.1 Preparing the Suspension for ODU Mounting andMounting the Antenna to the SuspensionPlease refer to Chapters 3.1.1 and 3.1.2 (this Section).
4.1.1.2 Mounting the Branching Support Bracket
M8x25
BRANCHINGSUPPORTBRACKET
B4008 Rev. M 71
ODU Type I Installation
4.1.1.3 Mounting the Rear Travers, Mounting the SuspensionSupport Bracket and Mounting the Feed on theBranching UnitPlease refer to Chapters 3.1.4 to 3.1.6 (this Section).
4.1.1.4 Installation of the HSB Branching Unit
BRANCHING UNIT
M8x25STUDS,NUTSANDWASHERS
72 B4008 Rev. M
CityLink
4.1.1.5 Installation of the Flexible Waveguide
M3 STUDS,NUT ANDWASHERS2 O-RINGS
M3 ALLENSCREWS,NUT ANDWASHERS
R220 FLEXIBLEWAVEGUIDE
O-RING
B4008 Rev. M 73
ODU Type I Installation
4.1.1.6 Installation of the Sunshield Support BracketPlease refer to Chapter 3.1.8 (this Section).
4.1.1.7 Installation of the Sunshield
SUNSHIELD
M4x16 SCREWS,NUTS ANDWASHERS
M6x25 SCREWS, NUTS,LARGE WASHERS ANDWASHERS
M4 ALLEN SCREW(FOUND MOUNTEDON THE BRANCHINGUNIT)
(PLACING OFLARGE WASHER)
74 B4008 Rev. M
CityLink
4.1.1.8 Mounting the Suspension/ODU to a Column or a WallPlease refer to Chapter 3.1.11 (this Section).
4.1.1.9 Mounting the ODU to the Antenna AssemblyBefore mounting the ODU to the antenna assembly, it is necessary toremove the protection lid from the antenna feed. Please refer to Chapter3.1.12 (this Section) for details.
B4008 Rev. M 75
ODU Type I Installation
4.1.1.10 Pole Mount4.1.1.10.1 Assembly of Branching Support Bracket
4.1.10.1.2 Installation of Branching Unit and Sunshield
BRANCHINGSUPPORTBRACKET
CLAMP
M8
M4
BRANCHING UNIT
SUN-SHIELD
M12 (Torque 19 NM)
Grounding point.See Section V Chapter 5.0 Fig. V-9
76 B4008 Rev. M
CityLink
4.1.2 Installation of 2+0 Equipment(Single Frequency Dual polarity)
4.1.2.1 Preparing the Suspension for ODU Mounting andMounting the Antenna to the SuspensionPlease refer to Chapters 3.1.1 and 3.1.2 (this Section).
4.1.2.2 Mounting the Branching Support Bracket, Mounting theRear Travers, Mounting the Suspension SupportBracket and Mounting the Feed on the Branching UnitsPlease refer to Chapters 3.1.3 to 3.1.6 (this Section).
M8 STUDS,NUTS ANDWASHERS
4.1.2.3 Installation of the Branching Units
B4008 Rev. M 77
ODU Type I Installation
4.1.2.4 Installation of the Flexible Waveguide
M3 STUDS,NUT ANDWASHERS
2 O-RINGS
M3 ALLENSCREWS,NUT ANDWASHERS
R220 FLEXIBLEWAVEGUIDE
O-RING
M3 ALLENSCREWS,NUT ANDWASHERS
M3 STUDS,NUT ANDWASHERS
2 O-RINGS
78 B4008 Rev. M
CityLink
4.1.2.5 Installation of the SunshieldM6x25 SCREWS,NUTS, LARGE WASH-ERS AND WASHERS
M4 ALLEN SCREW(FOUND MOUNTEDON THE BRANCHINGUNIT)
(PLACING OFLARGE WASHER)
M4 ALLEN SCREW(FOUND MOUNTEDON THE BRANCHINGUNIT)SUNSHIELDS
B4008 Rev. M 79
ODU Type I Installation
4.1.2.6 Mounting the Suspension/ODU to a Column or a WallPlease refer to Chapter 3.1.11 (this Section).
4.1.2.7 Mounting the ODU to the Antenna AssemblyBefore mounting the ODU to the antenna assembly, it is necessary toremove the protection lid from the antenna feed. Please refer to Chapter3.1.12 (this Section) for details.
80 B4008 Rev. M
CityLink
4.1.2.9.2 Installation of Branching Units and Sunshields
M8
M4
BRANCHING UNITS
SUN-SHIELDS
Grounding point.See Section V Chapter 5.0 Fig. V-9
4.1.2.9 Pole Mount4.1.2.9.1 Assembly of Branching Support Bracket
BRANCHINGSUPPORTBRACKET
CLAMPM12 (Torque 19 NM)
B4008 Rev. M 81
ODU Type I Installation
4.2 1.2m AntennaThis chapter only descibes how to install the CityLink branching supportbracket and the branching unit. For further instructions please refer to thehandbook supplied with the antenna (H2602; Installation Procedure for1.2m Antenna).
For installation of the transceiver, see Chapter 4.1.5.
4.2.1 Assembly of Branching Support Bracket
87m
m ±
5
BRANCHINGSUPPORTBRACKET
HORIZONTALGIRDER
VERTICALGIRDER
HORIZONTALGIRDER
BRANCHINGSUPPORTBRACKET
Make sure that the distance between the top of the branching supportbracket and the horizontal girder is 130mm ±3mm.
130m
m ±
3m
m
82 B4008 Rev. M
CityLink
4.2.2 Installation of Branching Unit, Sun-shield and FlexibleWaveguide
4.2.2.1 Hot Standby and 2+0 Dual Frequency Single Polarization
FLEXIBLEWAVEGUIDE
BRANCHING UNIT
M4 M8
SUN-SHIELD
NOTE!Most antennas are delivered with a bimetallic shim. This MUSTNOT be mounted for CityLink installations as the ODU, theflexible waveguide and the antenna all have aluminium waveguideconnectors.
Mount gasket(s) between the antenna feed and the flexiblewaveguide and also gasket(s) between the flexible waveguideand the branching unit. If the installation is placed in a verycorrosive environment, further protection can be achieved byadding silicon rubber.
Grounding point.See Section V Chapter 5.0Fig. V-9
B4008 Rev. M 83
ODU Type I Installation
4.2.2.2 2+0 Single Frequency Dual Polarization
FLEXIBLEWAVEGUIDES
BRANCHING UNITS
M4M8
SUN-SHIELDS
Grounding point.See Section V Chapter 5.0Fig. V-9
NOTE!Most antennas are delivered with a bimetallic shim. This MUSTNOT be mounted for 18-26GHz equipment as the ODU, theflexible waveguide and the antenna all have aluminiumwaveguide connectors. Flexible waveguides for 13-15GHz havesilver plated brass flanges and the bimetallic shim MUST beused (copper side facing flex-wg).
Mount gasket(s) between the antenna feed and the flexiblewaveguide and also gasket(s) between the flexible waveguideand the branching unit. If the installation is placed in a verycorrosive environment, further protection can be achieved byadding silicon rubber.
84 B4008 Rev. M
CityLink
5.0 Frequency Tuning at 13GHz &15GHz TransceiverThis chapter gives a short description of how to set and change frequencychannel on the transceiver. To perform this operation it is necessary toremove the cover and mount the transceiver to a branching connected toan IDU. A PC (where Nera software NEW is installed) and power arefurther connected to the IDU. A voltage meter and a screwdriver must alsobe available.
• Switch on the power at the system• Set wanted frequency in New.
Tables II-1 to II-9 give the relation between selected channel, duplex, TXHigh/Low and RX High/Low. The illustration on the next page gives anoverview of the tuning voltage connectors (VT TX and VT RX) and tuningscrews.
WARNING!This equipment contains components which are sensitive to"ESD" (Electro Static Discharge). It is therefore essential thatwhenever disassembling the equipment and/or handling PCboards, special precautions to avoid ESD have to be made.
This includes personnel grounding, grounding of work bench,grounding of tools and instruments. For the tuning process,it is also recommended to use a ceramic screw driver.
• Measure the tuning voltage VT TX continuously while adjusting thetuning screw. First turn the tuning screw CCW as far as it goes. Thenadjust it CW until VT TX reaches the correct voltage:
For 15GHz Transceiver; 4±0.5[V]For 13GHz Transceiver; 3±0.5[V]
• Measure the tuning voltage VT RX continuously when adjusting thetuning screw. First turn the tuning screw CCW as far as it goes. Thenadjust it CW until VT TX reaches the correct voltage:
For 15GHz Transceiver; 4±0.5[V]For 13GHz Transceiver; 3±0.5[V]
After tuning VT TX and VT RX to the correct voltage, the transceiver isconfigured to the correct frequency channel. Inspect the gasket andreplace the cover with use of correct torque (1.25Nm).
B4008 Rev. M 85
ODU Type I Installation
GND VT TX
Rx HighTx HighRx LowTx Low
VT RX
86 B4008 Rev. M
CityLink
Duplex frequency: 490 MHzChannel spacing: 28MHz
10L15L01A 10L15U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 14417 Low 1’ 14907 Low 1’ 14907 Low 1 14417 Low2 14445 Low 2’ 14935 Low 2’ 14935 Low 2 14445 Low3 14473 Low 3’ 14963 Low 3’ 14963 Low 3 14473 Low4 14501 Low 4’ 14991 Low 4’ 14991 Low 4 14501 Low5 14529 Low 5’ 15019 Low 5’ 15019 Low 5 14529 Low6 14557 Low 6’ 15047 Low 6’ 15047 Low 6 14557 Low7 14585 Low 7’ 15075 Low 7’ 15075 Low 7 14585 Low8 14613 Low 8’ 15103 Low 8’ 15103 Low 8 14613 Low9 14641 Low 9’ 15131 Low 9’ 15131 High 9 14641 Low
10 14669 High 10’ 15159 Low 10’ 15159 High 10 14669 Low11 14697 High 11’ 15187 Low 11’ 15187 High 11 14697 High12 14725 High 12’ 15215 High 12’ 15215 High 12 14725 High13 14753 High 13’ 15243 High 13’ 15243 High 13 14753 High14 14781 High 14’ 15271 High 14’ 15271 High 14 14781 High15 14809 High 15’ 15299 High 15’ 15299 High 15 14809 High16 14837 High 16’ 15327 High 16’ 15327 High 16 14837 High
Duplex frequency: 420 MHzChannel spacing: 28MHz
10L15L01A 10L15U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 14515 Low 1’ 14935 Low 1’ 14935 Low 1 14515 Low2 14543 Low 2’ 14963 Low 2’ 14963 Low 2 14543 Low3 14571 Low 3’ 14991 Low 3’ 14991 Low 3 14571 Low4 14599 Low 4’ 15019 Low 4’ 15019 Low 4 14599 Low5 14627 Low 5’ 15047 Low 5’ 15047 Low 5 14627 Low6 14655 Low 6’ 15075 Low 6’ 15075 Low 6 14655 Low7 14683 High 7’ 15103 Low 7’ 15103 Low 7 14683 High8 14711 High 8’ 15131 High 8’ 15131 High 8 14711 High9 14739 High 9’ 15159 High 9’ 15159 High 9 14739 High
10 14767 High 10’ 15187 High 10’ 15187 High 10 14767 High11 14795 High 11’ 15215 High 11’ 15215 High 11 14795 High12 14823 High 12’ 15243 High 12’ 15243 High 12 14823 High13 14851 High 13’ 15271 High 13’ 15271 High 13 14851 High14 14879 High 14’ 15299 High 14’ 15299 High 14 14879 High15 14907 High 15’ 15327 High 15’ 15327 High 15 14907 High
Duplex frequency: 728 MHzChannel spacing: 28MHz
10L15L01A 10L15U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 14515 Low 1’ 15243 High 1’ 15243 High 1 14515 Low2 14543 Low 2’ 15271 High 2’ 15271 High 2 14543 Low3 14571 Low 3’ 15299 High 3’ 15299 High 3 14571 Low4 14599 Low 4’ 15327 High 4’ 15327 High 4 14599 Low
Table II-1
Table II-2
Table II-3
B4008 Rev. M 87
ODU Type I Installation
Duplex frequency: 315 MHzChannel spacing: 28MHz
10L15L01A 10L15U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 14662 Low 1’ 14977 Low 1’ 14977 Low 1 14662 Low2 14690 High 2’ 15005 Low 2’ 15005 Low 2 14690 High3 14718 High 3’ 15033 Low 3’ 15033 Low 3 14718 High4 14746 High 4’ 15061 Low 4’ 15061 Low 4 14746 High5 14774 High 5’ 15089 Low 5’ 15089 Low 5 14774 High6 14802 High 6’ 15117 Low 6’ 15117 Low 6 14802 High7 14830 High 7’ 15145 High 7’ 15145 High 7 14830 High8 14858 High 8’ 15173 High 8’ 15173 High 8 14858 High9 14886 High 9’ 15201 High 9’ 15201 High 9 14886 High
Duplex frequency: 420 MHzChannel spacing: 14MHz
10L15L01A 10L15U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 14515 Low 1’ 14935 Low 1’ 14935 Low 1 14515 Low2 14529 Low 2’ 14949 Low 2’ 14949 Low 2 14529 Low3 14543 Low 3’ 14963 Low 3’ 14963 Low 3 14543 Low4 14557 Low 4’ 14977 Low 4’ 14977 Low 4 14557 Low5 14571 Low 5’ 14991 Low 5’ 14991 Low 5 14571 Low6 14585 Low 6’ 15005 Low 6’ 15005 Low 6 14585 Low7 14599 Low 7’ 15019 Low 7’ 15019 Low 7 14599 Low8 14613 Low 8’ 15033 Low 8’ 15033 Low 8 14613 Low9 14627 Low 9’ 15047 Low 9’ 15047 Low 9 14627 Low
10 14641 Low 10’ 15061 Low 10’ 15061 Low 10 14641 Low11 14655 Low 11’ 15075 Low 11’ 15075 Low 11 14655 Low12 14669 High 12’ 15089 Low 12’ 15089 Low 12 14669 Low13 14683 High 13’ 15103 Low 13’ 15103 Low 13 14683 High14 14697 High 14’ 15117 Low 14’ 15117 Low 14 14697 High15 14711 High 15’ 15131 High 15’ 15131 High 15 14711 High16 14725 High 16’ 15145 High 16’ 15145 High 16 14725 High17 14739 High 17’ 15159 High 17’ 15159 High 17 14739 High18 14753 High 18’ 15173 High 18’ 15173 High 18 14753 High19 14767 High 19’ 15187 High 19’ 15187 High 19 14767 High20 14781 High 20’ 15201 High 20’ 15201 High 20 14781 High21 14795 High 21’ 15215 High 21’ 15215 High 21 14795 High22 14809 High 22’ 15229 High 22’ 15229 High 22 14809 High23 14823 High 23’ 15243 High 23’ 15243 High 23 14823 High24 14837 High 24’ 15257 High 24’ 15257 High 24 14837 High25 14851 High 25’ 15271 High 25’ 15271 High 25 14851 High26 14865 High 26’ 15285 High 26’ 15285 High 26 14865 High27 14879 High 27’ 15299 High 27’ 15299 High 27 14879 High28 14893 High 28’ 15313 High 28’ 15313 High 28 14893 High29 14907 High 29’ 15327 High 29’ 15327 High 29 14907 High30 14921 High 30’ 15341 High 30’ 15341 High 30 14921 High
Table II-4
Table II-6
Duplex frequency: 644 MHzChannel spacing: 28MHz
10L15L01A 10L15U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 14515 Low 1’ 15159 High 1’ 15159 High 1 14515 Low2 14543 Low 2’ 15187 High 2’ 15187 High 2 14543 Low3 14571 Low 3’ 15215 High 3’ 15215 High 3 14571 Low4 14599 Low 4’ 15243 High 4’ 15243 High 4 14599 Low5 14627 Low 5’ 15271 High 5’ 15271 High 5 14627 Low6 14655 Low 6’ 15299 High 6’ 15299 High 6 14655 Low7 14683 High 7’ 15327 High 7’ 15327 High 7 14683 High
Table II-5
88 B4008 Rev. M
CityLink
Duplex frequency: 490 MHzChannel spacing: 14MHz
10L15L01A 10L15U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 14417 Low 1’ 14907 Low 1’ 14907 Low 1 14417 Low2 14431 Low 2’ 14921 Low 2’ 14921 Low 2 14431 Low3 14445 Low 3’ 14935 Low 3’ 14935 Low 3 14445 Low4 14459 Low 4’ 14949 Low 4’ 14949 Low 4 14459 Low5 14473 Low 5’ 14963 Low 5’ 14963 Low 5 14473 Low6 14487 Low 6’ 14977 Low 6’ 14977 Low 6 14487 Low7 14501 Low 7’ 14991 Low 7’ 14991 Low 7 14501 Low8 14515 Low 8’ 15005 Low 8’ 15005 Low 8 14515 Low9 14529 Low 9’ 15019 Low 9’ 15019 Low 9 14529 Low
10 14543 Low 10’ 15033 Low 10’ 15033 Low 10 14543 Low11 14557 Low 11’ 15047 Low 11’ 15047 Low 11 14557 Low12 14571 Low 12’ 15061 Low 12’ 15061 Low 12 14571 Low13 14585 Low 13’ 15075 Low 13’ 15075 Low 13 14585 Low14 14599 Low 14’ 15089 Low 14’ 15089 Low 14 14599 Low15 14613 Low 15’ 15103 Low 15’ 15103 Low 15 14613 Low16 14627 Low 16’ 15117 Low 16’ 15117 Low 16 14627 Low17 14641 High 17’ 15131 Low 17’ 15131 High 17 14641 Low18 14655 High 18’ 15145 Low 18’ 15145 High 18 14655 Low19 14669 High 19’ 15159 High 19’ 15159 High 19 14669 Low20 14683 High 20’ 15173 High 20’ 15173 High 20 14683 High21 14697 High 21’ 15187 High 21’ 15187 High 21 14697 High22 14711 High 22’ 15201 High 22’ 15201 High 22 14711 High23 14725 High 23’ 15215 High 23’ 15215 High 23 14725 High24 14739 High 24’ 15229 High 24’ 15229 High 24 14739 High25 14753 High 25’ 15243 High 25’ 15243 High 25 14753 High26 14767 High 26’ 15257 High 26’ 15257 High 26 14767 High27 14781 High 27’ 15271 High 27’ 15271 High 27 14781 High28 14795 High 28’ 15285 High 28’ 15285 High 28 14795 High29 14809 High 29’ 15299 High 29’ 15299 High 29 14809 High30 14823 High 30’ 15313 High 30’ 15313 High 30 14823 High31 14837 High 31’ 15327 High 31’ 15327 High 31 14837 High32 14851 High 32’ 15341 High 32’ 15341 High 32 14851 High
Table II-7
Duplex frequency: 266 MHzChannel spacing: 28MHz
10L13L01A 10L13U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 12765 Low 1’ 13031 High 1’ 13031 High 1 12765 Low2 12793 Low 2’ 13059 High 2’ 13059 High 2 12793 Low3 12821 Low 3’ 13087 High 3’ 13087 High 3 12821 Low4 12849 Low 4’ 13115 High 4’ 13115 High 4 12849 Low5 12877 Low 5’ 13143 High 5’ 13143 High 5 12877 Low6 12905 Low 6’ 13171 High 6’ 13171 High 6 12905 Low7 12933 Low 7’ 13199 High 7’ 13199 High 7 12933 Low8 12961 Low 8’ 13227 High 8’ 13227 High 8 12961 Low
Table II-8
B4008 Rev. M 89
ODU Type I Installation
Duplex frequency: 266 MHzChannel spacing: 14MHz
10L13L01A 10L13U01ATXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
TXCh.
TXFreq.
TXDRO
RXCh.
RXFreq.
RXDRO
1 12758 Low 1’ 13024 High 1’ 13024 High 1 12758 Low2 12772 Low 2’ 13038 High 2’ 13038 High 2 12772 Low3 12786 Low 3’ 13052 High 3’ 13052 High 3 12786 Low4 12800 Low 4’ 13066 High 4’ 13066 High 4 12800 Low5 12814 Low 5’ 13080 High 5’ 13080 High 5 12814 Low6 12828 Low 6’ 13094 High 6’ 13094 High 6 12828 Low7 12842 Low 7’ 13108 High 7’ 13108 High 7 12842 Low8 12856 Low 8’ 13122 High 8’ 13122 High 8 12856 Low9 12870 Low 9’ 13136 High 9’ 13136 High 9 12870 Low10 12884 Low 10’ 13150 High 10’ 13150 High 10 12884 Low11 12898 Low 11’ 13164 High 11’ 13164 High 11 12898 Low12 12912 Low 12’ 13178 High 12’ 13178 High 12 12912 Low13 12926 Low 13’ 13192 High 13’ 13192 High 13 12926 Low14 12940 Low 14’ 13206 High 14’ 13206 High 14 12940 Low15 12954 Low 15’ 13220 High 15’ 13220 High 15 12954 Low16 12968 Low 16’ 13234 High 16’ 13234 High 16 12968 Low
Table II-9
90 B4008 Rev. M
CityLink
6.0 Cable ConnectionsPlease refer to Section V Chapter 5.0.
7.0 Antenna AlignmentPlease refer to Section IV Chapter 6.0.
B4008 Rev. M 91
ODU Type II Installation
Installation ofODU Type II and Antenna
SECTION III
92 B4008 Rev. M
CityLink
1.0 GeneralThis section assumes that pre-planning of the link has been performed, i.e.path budgeting & survey to ensure good line-of sight between the two linkends.
1.1 PackingAny sensitive product, i.e. IDU and Printed Circuit Boards, are packed inspecial antistatic handling bags or boxes.
It is therefore essential that whenever unpacking or disassembling theequipment and or handling printed circuit boards etc., special precautionsto avoid ESD (Electro Static Discharge) should be taken, such as usingwrist grounding or corresponding protection.
The equipment is packed in sealed plastic bags which are equipped withrequired moisture protection.
All equipment is further packed in special designed cases prepared fortransportation.
Dimensions and weight of each case are specified in the "Packingspecifications" issued for the respective shipment.
1.2 MarkingMarking is done according to customers requirements. If such informa-tion is unavailable, the equipment is marked in the following way:
Customer addressContract No.Site Name (if known)Case No.
1.3 TransportationThe transport containers are prepared for shipment by air, truck, railwayand sea, suitable for handling by fork-lift trucks and slings.
The cargo must be kept dry during transport and storage.For sea-transport, deck-side shipment is not permitted and carrier-ownedcargo containers should be used.
B4008 Rev. M 93
ODU Type II Installation
1.4 Radio Equipment Inventory CheckLook for damage on the cases. Ensure that correct quantities of goods havearrived, according to the packing list in each package/unit.
Check also that the part description on the outside of each box corre-sponds to the components required for the installation, i.e. correct antennaand frequency, ODU frequency band and sub-band, IDU configuration.
Report any damages or missing items to Nera ASA by e-mail or fax. A shortdescription of damages, preferably including photographs, should be sentas soon as possible.
1.5 Preparation for InstallationComplete the required civil works. Transport all the equipment to site.Unpack the equipment and inspect for damage during transit to site andmake sure that the correct quantities of goods have arrived.
Units with static discharge protection should not be unpacked until theequipment installation takes place. Ensure you are grounded at a control-led ESD point before and during insertion, and during any subsequentunpacking of the unit.
1.6 Handling & StorageIt is recommended that components are stored and transported to theinstallation site in their original packing cases. If items are unpacked forstorage, they should be handled with care and protected during transpor-tation by similar protective materials.
The equipment is an electronic device which should be handled with care.It should be stored in dry, cool conditions, out of direct sunlight. Amoisture absorbing bag is taped inside the transportation unit to minimisecondensation during transportation. This is to be removed at installation.
No maintenance is required when stored according to particulars above.
To avoid damage to the sealing components and unwanted moist in theinterconnection interfaces, the transportation protection lids on the branch-ing and the transceiver must be kept on until mounting of waveguidecomponents and connection of the transceiver to the branching unit.
94 B4008 Rev. M
CityLink
2.0 Installation Equipment required2.1 Tools
The tools needed to install the equipment are listed in the following sub-chapters.
2.1.1 Tools for Antenna Installation• 2 pcs Combination Wrench 13 mm• 2 pcs Combination Wrench 16 mm• 2 pcs Combination Wrench 17 mm• 1 pc Torque Wrench 16 mm, 40 - 50 Nm
2.1.2 Tools for IDU- ODU Cable /Connector Mounting• 1 Hacksaw, fine-toothed• 1 Soldering Iron, 50-150W• Solder 36/37 RMA flux core• Cloth• 1 Knife• 1 Flat file, fine• 1 Wire brush• 1 Tape rule (or caliper)• 1 Heat gun, 1000W• 1 Cutting pliers
for hexagon coupling nut :• 1 Wrench 1/2" (13mm)• 1 Wrench 9/16" (15mm)• 1 Wrench 11/16" (18mm)• 1 Wrench 13/16" (21mm)
B4008 Rev. M 95
ODU Type II Installation
2.2 Equipment external to the Radio EquipmentIn addition to the necessary radio equipment & antenna the followingitems are needed:
• Coaxial cable between IDU and ODU. See Section V, chapter 5 foradvise on which cable to use.
• At least two N-type connectors suitable for termination of theselected coaxial cable.
• Suitable waveguide & flanges between antenna and branching unit ifremote mount option is used.
• Cable to ground the ODU.• Cable to ground the IDU.• Cable to power the IDU.• Cable to connect the PC, running the configuration & set-up program,
to the IDU.• Cable ties to secure cable runs.• Cables for user interfaces.
96 B4008 Rev. M
CityLink
3.0 ODU Installation3.1 Mounting the ODU to the Pole
The ODU can be mounted to a Ø75mm or a Ø115mm pole, see figurebelow.
2 x M10 NUTS ANDWASHER
SUN-SHIELD
U-BOLTS
Waveguide Flange type:PDR84
B4008 Rev. M 97
ODU Type II Installation
ODU BOTTOM VIEW:3.2 Cable Connections
Pressureequalizer
AGC Connector
IDU - ODU Cable Connector, N-50WFor details please see Figure V-7.
Ground connection. Attach ground-ing cable (10mm2) to this point withthe M6 nut and washers.
98 B4008 Rev. M
CityLink
4.0 Antenna and Waveguide Installation4.1 0.6m Antenna
Shim Copper/Aluminium
Copper side Alu side
Flange Adapter(NL2007 only)
B4008 Rev. M 99
ODU Type II Installation
4.2 1.2m Antenna
100 B4008 Rev. M
CityLink
4.3 2m Antenna
B4008 Rev. M 101
ODU Type II Installation
4.4 2.4m
102 B4008 Rev. M
CityLink
4.5 3m
317±20
B4008 Rev. M 103
ODU Type III Installation
Installation ofODU Type III and Antenna
SECTION IV
104 B4008 Rev. M
CityLink
1.0 GeneralThis section assumes that pre-planning of the link has been performed, i.e.path budgeting & survey to ensure good line-of sight between the two linkends.
1.1 PackingAny sensitive product, i.e. IDU and Printed Circuit Boards, are packed inspecial antistatic handling bags or boxes.
It is therefore essential that whenever unpacking or disassembling theequipment and or handling printed circuit boards etc., special precautionsto avoid ESD (Electro Static Discharge) should be taken, such as usingwrist grounding or corresponding protection.
The equipment is packed in sealed plastic bags which are equipped withrequired moisture protection.
All equipment is further packed in special designed cases prepared fortransportation.
Dimensions and weight of each case are specified in the "Packingspecifications" issued for the respective shipment.
1.2 MarkingMarking is done according to customers requirements. If such informa-tion is unavailable, the equipment is marked in the following way:
Customer addressContract No.Site Name (if known)Case No.
1.3 TransportationThe transport containers are prepared for shipment by air, truck, railwayand sea, suitable for handling by fork-lift trucks and slings.
The cargo must be kept dry during transport and storage.For sea-transport, deck-side shipment is not permitted and carrier-ownedcargo containers should be used.
B4008 Rev. M 105
ODU Type III Installation
1.4 Radio Equipment Inventory CheckLook for damage on the cases. Ensure that correct quantities of goods havearrived, according to the packing list in each package/unit.
Check also that the part description on the outside of each box corre-sponds to the components required for the installation, i.e. correct antennaand frequency, ODU frequency band and sub-band, IDU configuration.
Report any damages or missing items to Nera ASA by e-mail or fax. A shortdescription of damages, preferably including photographs, should be sentas soon as possible.
1.5 Preparation for InstallationComplete the required civil works. Transport all the equipment to site.Unpack the equipment and inspect for damage during transit to site andmake sure that the correct quantities of goods have arrived.
Units with static discharge protection should not be unpacked until theequipment installation takes place. Ensure you are grounded at a control-led ESD point before and during insertion, and during any subsequentunpacking of the unit.
1.6 Handling & StorageIt is recommended that components are stored and transported to theinstallation site in their original packing cases. If items are unpacked forstorage, they should be handled with care and protected during transpor-tation by similar protective materials.
The equipment is an electronic device which should be handled with care.It should be stored in dry, cool conditions, out of direct sunlight. Amoisture absorbing bag is taped inside the transportation unit to minimisecondensation during transportation. This is to be removed at installation.
No maintenance is required when stored according to particulars above.
To avoid damage to the sealing components and unwanted moist in theinterconnection interfaces, the transportation protection lids on the branch-ing and the transceiver must be kept on until mounting of waveguidecomponents and connection of the transceiver to the branching unit.
106 B4008 Rev. M
CityLink
2.0 Installation Equipment required2.1 Tools
The tools needed to install the equipment are listed in the following sub-chapters.
2.1.1 Tools for Antenna Installation and Adjustment• 2 pcs Combination Wrench M8, 13 mm• 2 pcs Combination Wrench M10, 16 mm• 2 pcs Combination Wrench M6, 10 mm• 1 pc Combination Wrench 10 mm• 1 pc Torque Wrench, M16, 24 mm, 120 Nm
2.1.2 Tools for IDU- ODU Cable /Connector Mounting• 1 Hacksaw, fine-toothed• 1 Soldering Iron, 50-150W• Solder 36/37 RMA flux core• Cloth• 1 Knife• 1 Flat file, fine• 1 Wire brush• 1 Tape rule (or caliper)• 1 Heat gun, 1000W• 1 Cutting pliers
for hexagon coupling nut :• 1 Wrench 1/2" (13mm)• 1 Wrench 9/16" (15mm)• 1 Wrench 11/16" (18mm)• 1 Wrench 13/16" (21mm)
B4008 Rev. M 107
ODU Type III Installation
2.2 Equipment external to the Radio EquipmentIn addition to the necessary radio equipment & antenna the followingitems are needed:
• Coaxial cable between IDU and ODU. See Section V, chapter 5 foradvise on which cable to use.
• At least two N-type connectors suitable for termination of theselected coaxial cable.
• Suitable waveguide & flanges between antenna and branching unit ifremote mount option is used.
• Cable to ground the ODU.• Cable to ground the IDU.• Cable to power the IDU.• Cable to connect the PC, running the configuration & set-up program,
to the IDU.• Cable ties to secure cable runs.• Cables for user interfaces.
108 B4008 Rev. M
CityLink
3.0 ODU / Antenna Installation, 1+0 Equipment3.1 Mounting the Antenna to the Suspension
All the described nuts and washers are included in the antenna assemblyand come attached to the antenna.
4ea M8 Nuts, washersand lock washers
SUSPENSION (3AB5158A)
ANTENNA(0,3m 0,45m and 0,6m)
B4008 Rev. M 109
ODU Type III Installation
3.2 Mounting the SunshieldThe Sunshield, screws, nuts and washers are found in the kit AZZ5495.
M6 Nuts, washersand lock washers(4ea)
M6 Screws (4ea)
SUNSHIELD
110 B4008 Rev. M
CityLink
U-BOLTS(ABZ5479 forcolumndiameterØ115mm,ABZ5480 forcolumndiameterØ75mm)
3.3 Mounting the Suspension/Antenna to a Column byusing the U-bolts
M10 Nuts, washers and lockwashers, 4eaTorque: 25-30Nm
B4008 Rev. M 111
ODU Type III Installation
CLAMPS, 2ea(ABZ5481)
M10 Nuts and washers, 4eaTorque: 35Nm
Column diameter:60-115mm
3.4 Mounting the Suspension/Antenna to a Column byusing the Clamps
112 B4008 Rev. M
CityLink
STEP 1 Mounting the Brackets on the Frame
4ea M8x20 screws8ea Flat washers4ea Lock washers4ea M8 Nuts(Kit:ABZ5774)
Bracket(Kit: ABZ5774)
Bracket(Kit: ABZ5774)
3.5 Mounting the Transceiver(without Antenna) to a Column
B4008 Rev. M 113
ODU Type III Installation
STEP 2 Attaching the Frame to the Column
2ea M10 U-bolts(Kit: ABZ5774)
4ea M10 Flat washers8ea M10 Nuts(Kit:ABZ5774)
114 B4008 Rev. M
CityLink
STEP 3 Mounting the Sunshields
Sunshields(Kit: ABZ5779)
2ea M5x12 screws8ea M5 flat washers4ea M5 lock washers4ea M5 nuts(Kit: ABZ5774)
B4008 Rev. M 115
ODU Type III Installation
STEP 4 Mounting the Transceiver
1+0 Configuration
1+1/HSB Configuration
116 B4008 Rev. M
CityLink
STEP 5 Mounting the Flexible Waveguide
1+0 Configuration
1+1/HSB Configuration
Mounting flange forflexible waveguide
Mounting flange forflexible waveguide
B4008 Rev. M 117
ODU Type III Installation
M10 Expansionbolts (typedependant onthe nature of thewall
M10 Nuts and washers
3.6 Mounting the Suspension/Antenna to a Wall
Ø10mm Pre-drilled holes
118 B4008 Rev. M
CityLink
3.7 Mounting the ODU to the Antenna AssemblyBefore mounting the ODU to the antenna assembly, it is necessary toremove the protection lid from the antenna feed. See below.
First remove the nuts usinga 5,5mm wrench.
Then remove the set screwsusing a 1,5 mm allen key.
Protection lid
B4008 Rev. M 119
ODU Type III Installation
LATCHES (4ea, onein each corner)
After adjustment;M16 torque = 110-120NmFor adjustment seeChapter 6.0.
To unlock the latches,push this handle forward
For correctpolarisation;see nextpage
120 B4008 Rev. M
CityLink
PolarizationThe electrical field is always orthogonal to the two opposing sides of thetwo broad sides of the rectangular waveguide.It is important to mount the ODU to the antenna with the right orientation.The arrows on the ODU's handle shall indicate the polarisation (vertical orhorizontal).
POLARIZATIO
NPO
LARIZATION
POLARIZATION POLARIZATION
UP
DOWNWaveguide feed withhorizontal polarisation
Waveguide feed withvertical polarisation
ODU orientation forvertical polarisation
ODU orientation forhorizontal polarisation
UP
DOWN
B4008 Rev. M 121
ODU Type III Installation
Bracket
Loosen this nut one turn.(See also Chapter 6.0)
Rotate the bracket 1800 byturning this bolt CW.
4.0 ODU / Antenna Installation,HSB and 2+0 Equipment
4.1 Preparing the Suspension for HSB and 2+0 Mounting
122 B4008 Rev. M
CityLink
4ea M8 Nuts and washers
4.2 Mounting the Antenna to the Supension
B4008 Rev. M 123
ODU Type III Installation
4.3 Mounting the Hybrid Frame to the Antenna
STEP 1Note! Mounting sequence is important!
2ea M8 Set screws, nuts,washers and lock washers
124 B4008 Rev. M
CityLink
M8 Screws,nuts and washers
STEP 2Note! Mounting sequence is important!
M8 Screws,nuts and washers
B4008 Rev. M 125
ODU Type III Installation
4.3 Mounting the CityLink III ODUs to the Antenna Assembly
LATCHES (1 in eachcorner of each ODU)
126 B4008 Rev. M
CityLink
4.4 Mounting the Transceiver(without Antenna) to the ColumnPlease refer to Chapter 3.5 (this Section).
4.5 Mounting the Suspension/Antenna to a WallPlease refer to Chapter 3.6 (this Section).
B4008 Rev. M 127
ODU Type III Installation
5.0 Cable Connections
ODU BOTTOM VIEW:
Pressure equalizer
AGC Connector.In a 1+1 configuation,this connector is usedfor interconnectionbetween the two ODUs.
Ground connection. Attachgrounding cable (10mm2) tothis point with the M6 nut andwashers.
IDU - ODU Cable Connector, N-50WFor details please see Figure V-7.
128 B4008 Rev. M
CityLink
6.0 Antenna Alignment
Azimuth Adjustment• Unlock securing nut approx. 1 turn before azimuth adjusting• Adjust azimuth• Lock securing nut after adjustment
Elevation Adjustment• Unlock securing nut approx. 1/2 turn before elevation adjusting• Adjust elevation• Lock securing nut after adjustment
6.1 Azimuth and Elevation Adjustment
Torque: 110-120Nm
Torque: 110-120Nm
6.2 Coarse adjustment.Adjust both antennas to correct direction as possible by using magneticcompass or optical sight.
6.3 Fine adjustmentFine adjustment is achieved by setting up a connection between theantennas. When the connection is established a readout of the AGC voltagecan be used to align the antennas. Loosen the antenna in both elevation andazimuth according to figure and adjust both azimuth and elevation untilmaximum signal is recived. Try a few times in each direction. The antennashould be turned so much that the first sidelobes are seen, thereby ensurethat the antenna is aligned on the mainlobe.
When the antenna is aligned in both azimuth and elevation the polarizationof the feed shall be realigned.
Finally ensure that all bolts and nuts are properly mounted and tighten.
The same procedure shall than be repeated on the opposite antenna.
B4008 Rev. M 129
ODU Type III Installation
6.5 Polarisation alignmentAlign the antenna approximately in both elevation and azimuth. Then usea water level to align the polarisation of the antenna feed to correctpolarisation according to figures below. Loosen the six M8 nuts that aresecuring the feed to the reflector and rotate the feed according to readoutof the water level. When the feed is in correct alignment, tighten the sixM8 nuts properly (do not overtight the nuts). Then the ODU can bemounted and the antenna has to be aligned. If the antenna has to be rotatedseveral degrees in azimuth or elevation, the polarisation has to be rea-ligned according to prior procedures.
Use these stud screws for aligning the feed with water level.
When the H mark is in upwards position, this shows that the antenna is Horizontal Polarized
Water level
Horizontal Polarisation:
6.4 Final ControlWhen all adjustments are performed, check that the input level agrees withthe calculated level. If the input level is to low, realign the antenna oncemore. Finally ensure that all bolts and nuts are properly mounted andtighten.
130 B4008 Rev. M
CityLink
Use these stud screws for aligning the feed with water level.
When the V mark is in upwards position, this showes that the antenna are Vertical Polarised
Water level
Vertical Polarisation:
B4008 Rev. M 131
IDU Installation
SECTION V V V V VIDU Installation
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR INP
G.703
OUT
-48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER 2
155 Mb/s LINE
PWRINP
G.703
OUT12
RXDIRARXDIRB
TXDIRATXDIRB
POWER 1
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR
132 B4008 Rev. M
CityLink
1.0 GeneralThis section assumes that pre-planning of the link has been performed, i.e.path budgeting & survey to ensure good line-of sight between the two linkends.
1.1 PackingAny sensitive product, i.e. IDU and Printed Circuit Boards, are packed inspecial antistatic handling bags or boxes.
It is therefore essential that whenever unpacking or disassembling theequipment and or handling printed circuit boards etc., special precautionsto avoid ESD (Electro Static Discharge) should be taken, such as usingwrist grounding or corresponding protection.
The equipment is packed in sealed plastic bags which are equipped withrequired moisture protection.
All equipment is further packed in special designed cases prepared fortransportation.
Dimensions and weight of each case are specified in the "Packingspecifications" issued for the respective shipment.
1.2 MarkingMarking is done according to customers requirements. If such informa-tion is unavailable, the equipment is marked in the following way:
Customer addressContract No.Site Name (if known)Case No.
1.3 TransportationThe transport containers are prepared for shipment by air, truck, railwayand sea, suitable for handling by fork-lift trucks and slings.
The cargo must be kept dry during transport and storage.For sea-transport, deck-side shipment is not permitted and carrier-ownedcargo containers should be used.
B4008 Rev. M 133
IDU Installation
1.4 Radio Equipment Inventory CheckLook for damage on the cases. Ensure that correct quantities of goods havearrived, according to the packing list in each package/unit.
Check also that the part description on the outside of each box corre-sponds to the components required for the installation, i.e. correct antennaand frequency, ODU frequency band and sub-band, IDU configuration.
Report any damages or missing items to Nera ASA by e-mail or fax. A shortdescription of damages, preferably including photographs, should be sentas soon as possible.
1.5 Preparation for InstallationComplete the required civil works. Transport all the equipment to site.Unpack the equipment and inspect for damage during transit to site andmake sure that the correct quantities of goods have arrived.
Units with static discharge protection should not be unpacked until theequipment installation takes place. Ensure you are grounded at a control-led ESD point before and during insertion, and during any subsequentunpacking of the unit.
1.6 Handling & StorageIt is recommended that components are stored and transported to theinstallation site in their original packing cases. If items are unpacked forstorage, they should be handled with care and protected during transpor-tation by similar protective materials.
The equipment is an electronic device which should be handled with care.It should be stored in dry, cool conditions, out of direct sunlight. Amoisture absorbing bag is taped inside the transportation unit to minimisecondensation during transportation. This is to be removed at installation.
No maintenance is required when stored according to particulars above.
134 B4008 Rev. M
CityLink
Figure V-2 Mounting the IDU in a Rack
Figure V-1 Mounting the Mechanical Adapters for ANSI or ETSI Rack
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR INP
G.703
OUT
-48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER 2
155 Mb/s LINE
PWRINP
G.703
OUT12
RXDIRARXDIRB
TXDIRATXDIRB
POWER 1
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR
ETSI RackAdapter
M6x12WASHER
FLAT WASHER
ANSI RackAdapter
2.0 IDU Installation2.1. Mounting the IDU in an ANSI (19") or an ETSI Rack
Mount the relevant mechanical adapters provided in the IDU package byusing the M3-6mm TORX screws also provided in the IDU package. Thelong adapters are for ETSI Rack, while the short are for ANSI Rack. SeeFigure V-1.Position the IDU in the rack and secure it by using the four M6-12mmscrews provided in the IDU package. See Figure V-2.
B4008 Rev. M 135
IDU Installation
2.2 Cable Installation Route, secure if necessary with cable ties, and terminate ground cable
between the IDU safety ground post and a nearby local safety groundpoint. Use the 6mm2 cable (2.5m long) included in the grounding kit.Refer to Figures X-1 and X-2 (Section X, Appendix 1) for the IDUsafety ground post location.
Route, secure if necessary with cable ties, the terminated IDU/ODUcable and connect to the ODU port of the IDU. See Chapter 5.0 (thisSection) for further details.
NOTE!Max torque = 5Nm when mounting the IDU/ODU cable.
Route and secure the power cable. The CityLink requires DC power(-40,5 to -57V) via a 2-pin connector. Refer to Figure X-7 (SectionX, Appendix 1) for a pinout of the connectors. It is recommended touse the supplied power cable, UWMK5051. The cable is left un-connected in one end. The black conductor must be connected to 0V(station gnd) and the blue conductor must be connected to -48V. Afterconnecting the cable to the power supply, measure polarity on powerconnector terminals.
Dependent on the purchased configuration of the IDU, route and attachall cables except the power cable. Refer to Section X, Appendix 1 forwiring details.
136 B4008 Rev. M
CityLink
Figure V-4 Mounting the Hot Standby IDUs in an ETSI Rack
3.0 Hot Standby IDU Installation(2+0 IDU installation is similar to ordinary IDU installation, see Ch. 2.0)
3.1 Mounting the Hot Standby IDUs in a RackMount the relevant mechanical adapters provided in the IDU package byusing the M3-6mm TORX screws also provided in the IDU package.SeeFigure V-1 (Chapter 2.1).Position the IDUs in the rack and secure them by using the four M6-12mmscrews provided in each IDU package. See Figures V-3 & V-4.
Figure V-3 Mounting the Hot Standby IDUs in an ANSI Rack
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFCCALL ALM & AUX LCT
NI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR INP
G.703
OUT
-48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFCCALL ALM & AUX LCT
NI 2
NI 1
CRITICALMAJORMINORWARNING
POWER 2
155 Mb/s LINE
PWRINP
G.703
OUT12
RXDIRARXDIRB
TXDIRATXDIRB
POWER 1
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR INP
G.703
OUT
-48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER 2
155 Mb/s LINE
PWRINP
G.703
OUT12
RXDIRARXDIRB
TXDIRATXDIRB
POWER 1
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR INP
G.703
OUT
-48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER 2
155 Mb/s LINE
PWRINP
G.703
OUT12
RXDIRARXDIRB
TXDIRATXDIRB
POWER 1
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFCCALL ALM & AUX LCT
NI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJOR
MINORWARNING
POWER
155 Mb/s LINE
PWR
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER
155 Mb/s LINE
PWR
ODU -48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJOR
MINORWARNING
POWER
155 Mb/s LINE
PWR
-48VDC
64kb/sG.703
2Mb/sWayside
SVCEExt. 1
Phone
64kb/sV.11
2MHzSync.
SVCEExt. 2
10BaseTLAN
IDU - HSB INTFC CALL ALM & AUX LCTNI 2
NI 1
CRITICALMAJORMINORWARNING
POWER 2
155 Mb/s LINE
PWRINP
G.703
OUT12
RXDIRARXDIRB
TXDIRATXDIRB
POWER 1
IDU A
IDU B
HSB-IDU
M6x12WASHER
FLAT WASHER
IDU A HSB-IDU
IDU B
M6x12
WASHERFLAT WASHER
B4008 Rev. M 137
IDU Installation
3.2 Interconnections in a Hot Standby SystemInterconnections between the IDUs in a Hot Standby system are done bymeans of a Y-cable. The cabel connectors are marked respectively IDU A,HSB-IDU and IDU B and this indicates which IDU they shall be connectedto. See Figure V-5.
Figure V-5 Interconnections in a Hot Standby System
IDU A
IDU B
HSB IDU
Y-Cable
WARNING!If the Y-cable connectors marked with IDU A and IDU B areswapped, the IDUs must always be rebooted after this opera-tion.
NOTE!Max torque = 5Nm when mounting the IDU/ODU cable.
138 B4008 Rev. M
CityLink
4.0 Installation of Optional Extension Boards
Step 1Remove the four screws that holds the lid
Step 2Use a flat screwdriver to carefully remove the lid.
WARNING!This equipment contains components which are sensitive to "ESD"(Electro Static Discharge). It is therefore essential that wheneverdisassembling the equipment and/or handling PC boards, special pre-cautions to avoid ESD have to be made.
This includes personnel grounding, grounding of work bench,grounding of tools and instruments.
B4008 Rev. M 139
IDU Installation
Step 3Remove screws and bushings (2ea) from the spacers and also the threescrews from the IDU front as shown below.
Step 4Remove the blindplates from the front of the IDU.
140 B4008 Rev. M
CityLink
Step 6Mount the new front using the three screws removed in Step 4 (only twoscrews for the 21x2Mbit/s Extension Board).
Step 7Remount the lid.
Step 5Mount the extension board. Press the extension board towards the IDU'sfront and push the rear edge downwards until you are able to mount thescrews and bushings in the spacers.
B4008 Rev. M 141
IDU Installation
5.0 IDU/ODU Cable InstallationBoth ends of the cable must be terminated with N-male connectors. Werecommend to use cables with outer conductor of solid corrugatedcopper.
For other cable types, the cable and all necessary installation materials mustbe arranged by the purchaser.
Cable length limitations are dependent upon cable type used. The tablebelow show limtations for some cables. Cable lenghts include cable ties.SeeTable V-1.
Table V-1 Cable length limitation due to different DC resistance
Table V-2 Selected Coax Cables and Connector Kits
Cable Type
DC resistance R
If the length is 100 m minimum voltage to
IDU must be
If the length is 200 m minimum voltage to
IDU must be
If the length is 300 m minimum voltage to
IDU must be
Bending radius
90 m (-40.5 V)* 100 m (-40.7 V) Dev. 0.2V
200 m (-43.5 V)
FSJ1-50A See Note 1
16.3 Ω/km
300 m (-46.0 V)
25 mm
180 m (-40.5 V)* 200 m (- 40.8 V) Deviation 0.3 V
LDF1-50 See Note 2
8,48 Ω/km
300 m (- 42.5 V)
75 mm
160 m (-40.5 V)* 200 m (-41.1 V) Deviation 0.6 V
LCF14-50J See Note 3
9.6 Ω/km
300 m (-42.9 V)
40 / 120 mm single / rptd
LCF38-50J See Note 4
5.0 Ω/km 50 / 95 mm single / rptd
*) Standard (ETSI) specified minimum supply voltage to IDU is –40,5 V
IDU to ODU Coax Cable
1 Cable Kit 100 m LCF14-50 100 m ¼” Coax Cable including 200 Cable Ties 85W5147-100 2 Cable Kit 150 m LCF14-50 150 m ¼” Coax Cable including 300 Cable Ties 85W5147-150 3 Cable Kit 200 m LCF14-50 200 m ¼” Coax Cable including 400 Cable Ties 85W5147-200 4 N-Connector Kit Connectors for IDU & ODU and Cable Grounding 87K5148-N 5 Preparation Tool for LCF14 Easy cable preparation for connector attachment 85W5147-TL For cable run 200 –300 m:
6 Cable & Connector Kit 300 m LCF38-50
300 m 3/8” Coax Cable including 600 Cable Ties and Connectors for ODU & IDU including jumper cable and Cable Grounding Kit
85W5011-K300
7 Extra Connector Kit Connectors for ODU & IDU including jumper cable and Cable Grounding Kit
87K5013-1A
8 Preparation Tool for LCF38 Easy cable preparation for connector attachment 85W5011-TL
Notes:1. Not selected as standard stock item.2. Standard cable kits are available as 100 m and 200 m3. Standard cable kits are available as 100 m, 150 m and 200 m4. Standard cable kits are available as 250 m and 300 m. Standard version ofLCF38-50 (6.7 Ω/km) can not be used. Only the cable type LCF38-50 with solidcopper inner conductor must be used (RFS part no. 152 225 11).
142 B4008 Rev. M
CityLink
• Avoid excessive bending. Run the cable where it is reasonable wellprotected and will not rub against sharp edges or overly abrasivesurfaces.
• The N-connectors should be tightened to the IDU and ODU accordingto the manufacturers installation instructions (provided with theconnectors) but with a max torque of 5Nm on the IDU.
• Leave enough slack in the cable termination to the ODU to allowantenna re-positioning.
• The cable connection to the ODU should be made weatherproofusing the cable connector weatherproof sleeve provided in theinstallation kit. See Figure V-7.
See Figure V-6 for Cable Arrangement.
B4008 Rev. M 143
IDU Installation
Figure V-6 Cable Arrangement, Mandatory Items
Item Description Part No. Remarks1 Coax Cable1a Cable Tie
See Table V-1,-2a & -2b
Supplied as Cable Kit,cable with ties (2 per m).
2a Connector, N-male, straight for ODU2b Connector, N-male, angle for IDU2c Grounding Kit for coax cable
See Table V-2a & -2b
Supplied as Connector Kit.
3a Grounding Cable for ODU3b Grounding Cable for IDU3c Grounding Jumper Cable IDU/SW
UWA7 Supplied as separate kit UWA7.
4 DC Power Supply Cable UWMK5051 Included in IDU connection kit and HSBIDU interconnection kit.
NOTE 1Weather protec-tion kit ABZ278(See Figure V-7)
Grounding point. (See Figure V-8)
ODU
Antenna
Equipment Earthing Bar
Buried Earthing Network
IDU B
IDU A
3a
4
1
1
3b
3c
2b
2a
Tower Structure
2c
1a
HSB-IDU
144 B4008 Rev. M
CityLink
Figure V-7 Coax Cable Connection
CABLE CONNECTION
OUTDOOR UNIT ODU
BOTTOM OFBRANCHING UNIT
PROTECTION SLEEVE97E12A-1
N - CONNECTOR
SEALING75N06D-1
HOSE CLAMP 97Z6A-5
BOTTOM OFBRANCHING UNIT
PROTECTIONSLEEVE
N - CONNECTORfemale, chassis
N - CONNECTORmale, cable
HOSE CLAMP
APPLY SEALING COMPOUND HERE
(NOTE 1)
1. Slide the Protection Sleeve and the Hose Clamp over the connector and onto the cable.
2. Connect the cable to the ODU. Press the protection sleeve over the connector and tighten theconnector by hand (using the sleeve gives a good hand-grip when tightening).
3. Pull the protection sleeve backwards and apply Sealing Compound (Plast 2000) onto the top end ofthe sleeve. Press the sleeve upwards and over the connector until it stops into the groove around theODU connector‘s nut and washer.
4. Adjust the clamp diameter with a screwdriver and slide in the clamp between the sleeve and theODU‘s cooling ribs and place it over the connector head.Tighten the clamp with a screwdriver.
NOTE:ALL CODED ITEMS AREINCLUDED IN KIT ABZ278
B4008 Rev. M 145
IDU Installation
Figure V-8 Branching Unit Grounding Point
Attach grounding cable (10mm2) to thispoint with the M8 nut and washers.
Figure V-9 Hot Standby and2+0 DF-SP Branching Unit Grounding Point
Attach grounding cable (10mm2) to thispoint with the M6 nut and washers.
WARNING!Do not use the Branching Unit's sealing screws for groundingpurpose.
WARNING!Do not use the Branching Unit's sealing screw for groundingpurpose.
146 B4008 Rev. M
CityLink
This page is intentionally left blank.
6.0 Change of Fan-CassetteFan cassette (if equipped) is located on the right hand side of the IDU. Thecassette may be replaced on live unit, without traffic interrupt. Withdraw oldcassette by pulling on knob on front of unit and replace with new unit.
Some combinations of circuit boards requires the use of fan-cassette in orderto control heat. In case a fan-cassette is to be installed in a unit not previouslyhaving one, a blind front cover will have to be unscrewed and discardedbefore installing a new cassette.
B4008 Rev. M 147
Preparations for Operation
Preparationsfor
Operation
SECTION VI
148 B4008 Rev. M
CityLink
1.0 GeneralThis section assumes that the radio terminal has been installed accordingto the guidelines in Sections II - V.
1.1 Equipment required• Voltmeter for AGC voltage monitoring (with cable to connect to
BNC-connector)• Cable for connection between AGC monitoring point and voltmeter.
1.2 ConnectionsSee Appendix I for a more detailed description of connectors.
Verify the following:• Correct line interface plug-in board is installed.• Cable for main traffic is connected.• Connection of IDU safety ground. Use min. 10 mm2 cable.• Coaxial cable between IDU and ODU is connected.• Cable between IDU and the PC running the configuration & set-up
program is connected. NOTE: RJ-45 modular plugs used on patchcables etc. must mechanically comply with Federal CommunicationsCommission - Part 68 (FCC-68).
Optionally the following connections may be used:• ALM/AUX connector for parallel alarm inputs and outputs.• 2x64kbit/s connector for 64kbit/s serial channels utilising bytes in
the Section Overhead.• NI-1 and/or NI-2 connectors for interface to other Nera equipment.• 2Mbit/s WAYSIDE connectors for interface to 2Mbit/s wayside
traffic channel utilising bytes in the Section Overhead.• 2MHz SYNC connectors for synchronisation purposes.• Handset and extension connectors.• LAN Interface connectors.
2.0 Power onApply power to the IDU by connecting the power cable. The radio linkstart-up procedure and self-diagnostics will start to execute.
When power is applied to the IDU the system will perform self test, thiswill take a few seconds.
B4008 Rev. M 149
Preparations for Operation
2.1 NEW-NMS/NEW-Configurator Startup andconnecting to Network ElementsThe NEW-NMS/NEW-Configurator (Nera Element vieW-Network Man-agement System/ -Configurator) program must be installed on a PCsatisfying the following minimum requirements:
• NT4.0/Win95/Win98 operating system• Pentium 133MHz processor• 32MB memory• 200MB disk size• 1 COM port• CD-ROM drive
Follow carefully the program installation instructions to make sure theprogram is successfully installed.
The element viewer can monitor the Network Elements (NEs) using aserial connection (RS-232) or a TCP/IP connection (or both for differentnetwork elements). Apply all external connections to the PC before theprogram is started.
A serial connection must be used the first time the network manager/configurator is connected to the CityLink, because the IP address must beset in the CityLink, before a TCP/IP connection can be established.
2.1.1 Starting NEW-NMS/NEW-Configurator withSerial Connection (RS-232/ LCT).Apply the serial cable to one of the serial ports of the PC and the LCT portof the CityLink. Start the program. A Log on dialog box pops up. Log onto the network with your user id and password.
Note!NEW-NMS' security system has initially one user account:
User ID: adminPassword: adminpasswd
It is strongly recommended to change this password!
The program has an auto discover function which automatically discoversNEs connected to the serial ports of the PC when starting. If some NEs areconnected to the serial ports of the PC, the network topology is automat-ically discovered and presented in the Explorer view. Press Add to includediscovered elements in the network topology of the program. The autodiscover function can also be manually executed by selecting Discover
150 B4008 Rev. M
CityLink
from the File menu. When discovering the network manually, the programlooks for NEs at the open ports listed in the Communication dialog box(select Communication from the Configuration menu).
2.1.2 Starting NEW-NMS/NEW-Configurator withTCP/IP Connection.(Assumes the TCP/IP address is configured in the CityLink )Apply Ethernet connections to both the CityLink and PC. Start theprogram. A Log on dialog box pops up. Log on to the network with youruser id and password.
Note!NEW-NMS' security system has initially one user account:
User ID: adminPassword: adminpasswd
It is strongly recommended to change this password!
The program does not know the IP-address of the network element so theconnection must be manually established. To configure a TCP/IP connec-tion to the network element, select Communication from the Configu-ration menu. Press the Add button and type the IP address of the NE inthe address field of the dialog box which pops up. Press OK to save thechanges, and OK to close the Communication Configuration dialog box.Select Discover from the File menu. Press Add to include discoveredelements in the network topology of the program. The accepted networkelements will be discovered and presented in the Explorer view.
2.2 Initial configurationWhen the program has established contact with the CityLink, someconfigurations must be set before antenna alignment can be performed.
A Configuration Wizard will guide you through the initial configurations.Start the Wizard by selecting the network element in the Explorer view.Then select Configuration > Wizard from the right mousebutton contextmenu. Follow the Wizard instructions.
All the configuration settings are described in Section VII; Configuration.
You are now ready to proceed with antenna alignment. Please refer toSection IV Chapter 6.0 (ODU Type I & III) or the installation manual forthe actual antenna (ODU Type II)
B4008 Rev. M 151
Configuration with NEW-Configurator
Configuration byNEW Configurator
SECTION VII
152 B4008 Rev. M
CityLink
1.0 GeneralThis section assumes that the Preparations for Operation described inSection VI has been performed for the complete radio link hop.
Configuration of the Network Elements is done from the Explorer Viewwhich can be launched by selecting Explore Net from the View menu.
Configuration of Network Elements is achieved using a set of property-sheets. The property-sheets are modeless, so configuration of severaldifferent modules can be displayed simultaneously.
To open the configuration property-sheets:Press the Right mouse-button on the Network Element node/leaf youwant to view/change the current configurations. A dynamic menu pops up.Open the Configuration sub-menu and select the configuration-specificmenu item.
The configuration property sheets can also be launched by selecting/marking an NE node/leaf in the Explorer View and then selecting theconfiguration-specific menu item under the Edit sub menu in the Config-uration menu.
The property-sheets are divided into two categories by means of function-ality:
Configuration Property sheets with Multiple Settings:The program retrieves the current settings from the NE when the property-sheet is opened. No message is sent to the element and no data is modifiedin NEW’s data structure before the user presses one of the property-sheetbuttons:
Figure VII-1 Buttons on Configuration property sheets with multiple settings
Buttons:Get: Retrieves the current settings from the NE.Set: Sends the current settings to the NE.Close: Closes the property-sheet without saving or setting any dataHelp: Displays help for the active property-page.
.
B4008 Rev. M 153
Configuration with NEW-Configurator
••••• To change the settings:1 Get the current settings from the NE by pressing Get.
The current NE settings are automatically retrieved when the property-sheet is opened.
2 Alter the settings.3 Press Set to send the changes to the NE.
Configuration Property sheets with Single Interactive Settings:The program retrieves the current NE settings when the property-sheet isopened. Has no Get, Set or Save buttons; All functional buttons are placedin the property-pages. A message is sent to the Network Element imme-diately when a control is changed or a button is pressed.
Property-sheet buttons:
Figure VII-2 Buttons on Configuration property sheets withsingle interactive settings
Buttons:Close:Closes the property-sheet.Help: Displays help for the active property-page.
Figure VII-3 Configuration property sheet information field
All property-pages have an information field at the bottom reflecting thecurrent status of the data shown in the property-page and the date and timethe property sheet data was retrieved from the network element.
154 B4008 Rev. M
CityLink
2.0 Element Node2.1 Element Id
The CityLink Element Id property sheet shows some main informationabout the Network Element like name, type, serial number and differentaddresses. The fields with white background can be altered by users withproper user privileges. The gray fields are non editable.
The Element Id configuration sheet can be opened from the Configura-tion context menu of the Element node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit Element Id from the Configura-tion menu.
Figure VII-4 Element ID Configuration Sheet
B4008 Rev. M 155
Configuration with NEW-Configurator
Fields: Description:Serial number: The serial number of the NE. (Not editable)NE type: The type of NE. (Not editable)Name: The name of the NE (max. 32 characters)Section address: The section address of the NE. (1-254)NE address: The NE address (1-128). Used for identification of
NEs within a section.MAC address: The Media Access Control address of the NE.
Used for OSI-Management. (Not editable)NSAP address: The Network Service Access Point address of the NE.
Used for OSI-Management.IP address The Internet Protocol address of the NE.Hot standby: This field is checked if the NE is a hot standby element.
To change the settings:1 First, get the current settings from the NE by pressing Get.
(The settings are automatically retrieved from the NE when theproperty-sheet is opened.)
2 Alter the settings you want to change.3 Press Set to send the changes to the NE.
156 B4008 Rev. M
CityLink
2.2 Available FunctionsThe available functions property sheet shows the functions available at thenetwork element. All these functions are additional CityLink functions.The user has paid extra to get these functions. Contact your Nera equip-ment supplier to order functions. You will get an encrypted authenticationstring in return.
The Available Functions configuration sheet can be opened from theConfiguration context menu of the Element node in the Explorer view.The sheet can also be invoked by selecting (highlighting) the Elementnode in the Explorer view and then selecting Edit Available Functionsfrom the Configuration menu.
Figure VII-5 Available Functions Configuration Sheet
Fields: Description:Automatic transmitted ATPC is a function for effectively reducingpower control (ATPC) interference probabilities..IP stack The NE has an integrated IP stack.
Synchronous equipment Synchronous equipment timing source istiming source (SETS) available.Simple network management An SNMP management agent is available.protocol (SNMP)
64 Kbit/s channels Two 64 Kbit/s channels can be inserted intothe STM-1 Section Overhead (SOH ).
2 Mbit/s wayside channel One 2Mbit/s wayside channel can be insertedinto the STM-1 Section Overhead (SOH ).
Alarm auxiliary function A unit containing an auxiliary alarm unitand an auxiliary output unit is available.
STM-1
B4008 Rev. M 157
Configuration with NEW-Configurator
2.3 NotificationsThe NE can send notifications to NEW when specific events occur. Whenusing notifications, NEW gets new information faster than if only pollingis used. Polling should however be used in addition to notifications. TheNE keeps individual notification settings for each NEW that is logged onto the NE, such that the settings made from one NEW only apply to thatNEW. Note that the settings will be reset to default when NEW logs on tothe NE or when the IDU is reset.
A notification is enabled when the corresponding checkbox is checked ( ).
The Notifications configuration sheet can be opened from the Configu-ration context menu of the Element node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit Notifications from the Config-uration menu.
Figure VII-6 Notifications Configuration Sheet
158 B4008 Rev. M
CityLink
Fields: Choices: Description:
Event s Alarm When checked, Alarm notifications will be
sent from the NE to the program. Security When checked, Security notifications will
be sent from the NE to the program. Switching When checked, Switching notifications will
be sent from the NE to the program.
Alarm (When the Alarm Events is disabled,severity these functions are inactive)
Critical When checked, Alarm notifications will besent from the NE to the program if Criticalalarms occur.
Major When checked, Alarm notifications will besent from the NE to the program if Majoralarms occur.
Minor When checked, Alarm notifications will besent from the NE to the program if Minoralarms occur.
Warning When checked, Alarm notifications will besent from the NE to the program if Warningsoccur.
B4008 Rev. M 159
Configuration with NEW-Configurator
2.4 NE Clock PageThe NE Clock sheet lets you synchronize the Network Element Date/Timewith the NEW-NMS / PC Date/Time. (The NE Clock is set to the samedate/time as the PC Clock).
The NE Clock configuration sheet can be opened from the Configurationcontext menu of the Element node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit NE Clock from the Configura-tion menu.
Fields: Description:The NE's Clock: The Date and Time retrieved from the
Network Element.Difference from The difference between the PC clock and the
Network Element Clock.
Figure VII-7 NE Clock Configuration Sheet
160 B4008 Rev. M
CityLink
2.5 Software DownloadCityLink Application software can be downloaded through the NEW-NMS/NEW-Configurator program.
The SW Download configuration can be started from the Configurationcontext menu of the Element node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit SW Download from the Config-uration menu.
To download new NE application code:1. The process of downloading starts with selecting the file containing
the application code. The file has extension: .bin. When a .bin-file isselected, a dialog box will appear.
2. Verify that the correct version of the code file is chosen. Press Cancelif wrong code file is chosen.
3. Press Start Download4. Wait until the download is finished.
New application software is now downloaded at the NE. Now the NE muststart to use the new software. The new software will not start to executeuntil it is activated. This is done from the SW Version property sheet.
B4008 Rev. M 161
Configuration with NEW-Configurator
2.6 Software VersionsThe SW versions property sheet shows the software revisions and theirstatus. The IDU contains two application code memory banks for both theSU (IDU) and the Transceiver (ODU). Both the IDU and the ODU useapplication code from one bank, while the other bank is available for SWdownload. New software can be downloaded (see Chapter 2.5 SWDownload) in the unused bank while the IDU or ODU is executing the codeof the other bank. The user may also select which bank to execute theapplication from if both banks contain valid software.
The ODU contains an application code software bank in addition to the twobanks in the IDU. The ODU software is copied from the active IDU bankto the ODU bank during the ODU boot process.
The SW Versions configuration sheet can be opened from the Configu-ration context menu of the Element node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit SW Versions from the Config-uration menu.
Figure VII-8 SW Version Configuration Sheet
162 B4008 Rev. M
CityLink
Fields: Description:SW Component Name of the softwareBank Software locationRevision Software revisionStatus Idle:Software is not being executed.
Active:Software is being executed.Loading: SW is downloading to this bank.Invalid: Incomplete or invalid SW; SW bankhas not been used or a SW download hasfailed.Not contact with unit: The IDU does nothave contact with the unit containing this SW.
To activate a memory bank:1 Select the unused bank (status: Idle) by clicking the left mouse button.2 Press the Set Active button
The NE will be reset and when it starts, the application code of the chosenbank will be executed.
B4008 Rev. M 163
Configuration with NEW-Configurator
3.0 Transmission Node3.1 Transmission Configuration (Section Termination)3.1.1 Section Termination, SW-version < R2A00
The CityLink Section Termination sheet shows the channel configurationof the network element. For CityLink systems, the number of the differentchannel settings is fixed. Only the Channel Termination can be changed.The Section Termination configuration sheet can be opened from theConfiguration context menu of the Transmission node in the Explorerview. The sheet can also be invoked by selecting (highlighting) theTransmission node in the Explorer view and then selecting Edit SectionTermination from the Configuration menu.
Fields: Description:Regular channels: The Number of Regular Channels.Protection channels: The Number of Protection Channels.Regular co. channels: The Number of Regular Co. Channels.Protection co. channels: The Number of Protection Co. Channels.Channels: List of NE Channels with the channel properties.
Channel Name of the channel.Termination MS (Multiplexer section) or RS (Regenerator Sec-
tion) (Double-click the field to edit).The MS and RS are parts of the STM-1 Sectionoverhead. Together MS and RS form the total SOH.
Figure VII-9 Section Termination Configuration Sheet
To change the settings:1. Get the current settings from the NE by pressing Get.2. Alter the settings you want to change. To change the Termination
settings, double-click in the appropriate cell in the list. A Combo-boxwhere you can select RS or MS is then displayed
3. Press Set to send the changes to the NE.
164 B4008 Rev. M
CityLink
3.1.2 Transmission Configuration, SW-version ≥≥≥≥≥ R2A00The Transmission Configuration sheet is used to set the transmissionstandard and termination on the element. When the applied termination isdifferent from RST, the sheet is also used to configure the SETS functionality.
A CityLink element may support different extension boards. This includesthe DS3/E3 Extension Board, the STM-1 Extension Board or the 21x2Mbit/s tributary board. Each element will, however, only support one extensionboard at a time. From the Transmission Configuration sheet the user canenable the functionality of the specific extension board. The 21x2Mbit/sextension board assumes a frame structure which contains 63 E1s. To enablethis board, select the termination to be Lower Order Path Termination -LOPT. If the DS3/E3 Extension Board or the STM-1 Extension Board ismounted, the frame structure must be set explicitly.
The Transmission Configuration configuration sheet can be opened fromthe Configuration context menu of the Transmission node in the Explorerview. The sheet can also be invoked by selecting (highlighting) the Trans-mission node in the Explorer view and then selecting Edit TransmissionConfiguration from the Configuration menu.
Figure VII-10 Section Termination Configuration Sheet
B4008 Rev. M 165
Configuration with NEW-Configurator
Fields: Description:Termination Enabling The type of termination this element shall
support. Legal values are:• RST• MST• Lower Order Path Termination - LOPT• Enable X-Connect (available only if X-
Connect Extension Board is equipped)• Enable DS3/E3 (available only if DS3/E3
Extension Board is equipped)Note: If this setting is changed and applied tothe element, the equipment will perform a soft-ware reset.
Transmission Standard The Transmission System used. Legal values are:• SDH• SONET
Element Type The type of «timing element» we’re supposed tobe. This is important in a network where SETS isapplied. Legal values are:
• SEC• SSU Local (G.812 Local)• SSU Transit (G812 Transit)• PRC
SSU Clock Source This field will only be enabled whenever theElement Type is set to either SSU (G.812Local) or SSU (G.812 Transit). The SSU is an
external clock regenerator or filter that will remove jitter fromthe clock on its input. It will then output a regenerated clock on itsoutput. The SSU is connected to the element via the
2MHz synch RJ-45 plug on the front of the IDU.The clock source can be one of the following:
• LINE• RADIO• Any dropped 2Mbit/s• LINE EXT
The last option will only be available if the X-Connect Extension Board is present.
166 B4008 Rev. M
CityLink
SSU Squelch Level This field will only be enabled whenever theElement Type is set to either SSU (G.812 Local) orSSU (G.812 Transit). If the quality of the clock sourcechanges to a quality that is below this «qualitysquelch» level, the 2MHz synch output to the SSUwill be squelched. This in turn will cause the SSU toenter holdover mode (or free-running), i.e. the clockquality it sends to the 2MHz synch input will have aG.812 quality (ref. ITU-T Recommendation G.812)that is based upon the internal oscillator in the SSU.Legal squelch levels are:
• Better or equal G.813• Better or equal G.812 Local• Better or equal G.812 Transit• Equal G.811
Clock Priority This is the first column in the Clock Priority list view.This field will only be enabled whenever the ElementType is set to SEC. This is just a number specifyingthe priority of the rows where 1 is the higher priority.The user can not change anything in this column.
Clock Source This is the second column in the Clock Priority listview. This field will only be enabled whenever theElement Type is set to SEC. If e.g. the user doubleclicks the first cell in this column, a combobox will beshown over the cell. The user can than select fromwhere the clock to this priority list item shall be taken.This can also be done for the 2nd and 3rd cell in thiscolumn. The 4th cell, on the other hand, is the internaloscillator which will be used whenever the element isin holdover mode. This cell can’t be altered. Legalvalues are:
• LINE• RADIO• 2MHz Synch• LINE EXT
Note: Only one of the priority list items can beconfigured to take its clock source from a 2Mbit/stributary at the time. This is due to HW constraints.
B4008 Rev. M 167
Configuration with NEW-Configurator
Clock Quality This is the third column in the Clock Priority list view. Thisfield will only be enabled whenever the Element Type is setto SEC. If the Clock Source field for a specific priority listitem is set to either STM-1 LINE or STM-1 RADIO, thecorresponding cell in this column will be set to SSM andwill be grayed out (i.e. disabled). This means that the contentof the S1-byte (located in the MSOH) will inform the elementof which clock quality the traffic in the specific directions isclocked with. If the Clock Source field for a specific prioritylist item is set to be taken from the 2MHz Synch input, or itis to be taken from a 2Mbit/s tributary, their clock qualityaren’t embedded in the traffic in any way. This meansthat the user will have to set their clock qualities manually.In these cases, the cell in question in this column will beenabled and the user can set the quality. Legal values are:
• G.813• G.812 Local• G.812 Transit• G.811
In addition to these, SSM will also be present in the list butcan not be selected.Note: Ref. ITU-T for more information regarding thedifferent G.8xx recommendations.
Enabled This is the fourth column in the Clock Priority list view.This field will only be enabled whenever the Element Typeis set to SEC. If a specific priority list item has this cellchecked it will be present in the clock priority scheme. Ifnot it is ignored.
Active Priority This is the fifth column in the Clock Priority list view. Thisfield presents the currently active clock. The field isupdated each time the “GET” button is pressed.
Note: If the user, by means of the Drop or Continue dialog, removes any ofthe tributaries in the list above, they will automatically be removed fromthe list!
Buttons:SSM Dialog: This button will only be visible when the in user level of the
logged in user is equal to or greater than Administrator. Itwill spawn a new dialog that will poll for the SSM in bothradio- and line direction of the STM-1 traffic.
168 B4008 Rev. M
CityLink
Get: Click this button to retrieve the current settings from theNE. Any modifications done to the GUI elements will belost and the «dirty» token will be removed.
Set: Click this button to send the settings to the NE. Anymodifications done to the GUI elements will be applied
the NE and the «dirty» token will be removed.Close: Click this button to close the property sheet.Help: Press this button to get help on the current property sheet.
For help on an item, click at the top of the dialog box,then click the item.
A brief description of the different terminations:RST:This is the default setting on the element when delivered from the factory.With this configuration the SDH structure is ignored, i.e. it can be anythingbecause the virtual containers will not be accessed. The equipment willmonitor and re-generate B1 pulses. M1 REI and B2 will only be monitored.Figure VII-11 shows the Transmission Configuration dialog when thissetting is applied.Note: When the element is RST, all the SETS elements of the dialog aredisabled. This is because SETS only is used when the element is configuredas MST or Lower Order Path Termination - LOPT. Even though the SETSfunctionality is disabled, the user can see the last applied MST settings.
Figure VII-11 Transmission Configuration, RST
B4008 Rev. M 169
Configuration with NEW-Configurator
Figure VII-12 Transmission Configuration, MST
MST:With this configuration the SDH structure is ignored, i.e. it can be anythingbecause the virtual containers will not be accessed. The equipment willmonitor and regenerate B1-, M1 REI- and B2-pulses. Figure VII-12 showshow the dialog looks when this setting is applied.
Figure VII-13 Transmission Configuration, LOPT
Lower Order Path Termination - LOPT:With this configuration the SDH structure is assumed to have a VC-12mapping and the the equipment will monitor and regenerate B1, M1 REI, B2and BIP-2 pulses. Figure VII-13 shows how the dialog looks when this settingis applied.
170 B4008 Rev. M
CityLink
Enable X-Connect:To enable the X-Connect functionality, select “Enable X-Connect” from the“Termination enabling” combo box and press the “SET” button. The SDHstructure may be configured from the “Frame Structure” page.
Enable DS3/E3:To enable the DS3/E3 functionality, select “Enable DS3/E3” from the“Termination enabling” combo box and press the “SET” button. The SDHstructure may be configured from the “Frame Structure” page.
Figure VII-14 Transmission Configuration, Enable X-Connect
Figure VII-15 Transmission Configuration, Enable DS3/E3
B4008 Rev. M 171
Configuration with NEW-Configurator
Enable 21x2:This functionality is only available with new target software. To enable the21x2 functionality, select “Enable 21x2” from the “Termination enabling”combo box and press the “SET” button. The SDH structure may be config-ured from the “Frame Structure” page.
Figure VII-16 Transmission Configuration, Enable 21x2
172 B4008 Rev. M
CityLink
Fields: Description:Direction From which STM-1 direction the S1 byte is monitored.
This can be either Line or RadioLast change Will show the last time the specific S1 byte changed it’s
value.S1 byte The current content of the specific S1 byte.Description A human readable interpretation of the S1 byte. These can
be:
3.1.3 SSM - Synchronization Status MessageThe SSM sheet is used to monitor the received S1-byte in the two STM-1 directions; LINE and RADIO.
The SSM - Synchronization Status Message configuration sheet can beopened from the Section Termination sheet by clicking the SSM Dialogbutton on this sheet.
Note: The SSM Dialog button will only be visible for Administratorusers in the Section Termination sheet.
Figure VII-17The SSM Configuration Sheet
B4008 Rev. M 173
Configuration with NEW-Configurator
3.2 Alarm Indication Signal Insert(For advanced users)The Path Trace functionality and the AIS (Alarm Indicator Signal) function-ality are used for verifying that the received STM-1 frames are the frames wewant to receive (correct routing, frequency alignment...). This is done byeither inserting a fixed byte or a user defined ASCII string in the J0 slot in theRSOH, or a two bit RF ID symbol at the transmit end. This is done from thepath trace sheet. The RF ID functionality is only available at the Radio side.The radio that receives the STM-1 frames must have the same Trace string(J0) or RF ID defined in the AIS insert sheet. If there is a mismatch, an AIScan be inserted. An AIS can also be inserted if the HBER threshold isexceeded.
The AIS Insert configuration sheet can be opened from the Configurationcontext menu of both the Transmission Radio and Line Rx nodes in theExplorer view. The sheet can also be invoked by selecting (highlighting)one of the Transmission Radio and Line Rx nodes in the Explorer viewand then selecting Edit AIS Insert from the Configuration menu.
S1 byte SDH synchronization quality level description0000 Quality unknown (existing sync network)0001 Reserved0010 G.8110011 Reserved0100 G.812 transit0101 Reserved0110 Reserved0111 Reserved1000 G.812 local1001 Reserved1010 Reserved1011 Synchronous equipment timing source (SETS)1100 Reserved1101 Reserved1110 Reserved1111 Do not use for synchronization
174 B4008 Rev. M
CityLink
Fields: Subfields: Description:
Insert AIS when An AIS is inserted when the Viterbi HBERViterbi HBER threshold is exceeded. (See Chapter 4.4.9threshold exceeded for setting of BER threshold.)
Insert AIS when An AIS is inserted when there is a mismatchtrace mismatch between the Trace String set in the Path Trace
sheet and Trace String set on this sheet.
Insert AIS when An AIS is inserted when there is a mismatchRF ID mismatch between the RF ID set in the Path Trace
sheet and RF ID bit set on this sheet.The RF ID functionality is only available atthe Radio node.
AIS remove delay 1 - 200 seconds
Regeneratorsectiontrace (J0) Not used The Regenerator Section Trace String is not
used.Fixed byte The Regenerator Section Trace String is one
byte ( =8 bit) long.
Figure VII-18 AIS Insert Configuration Sheet
B4008 Rev. M 175
Configuration with NEW-Configurator
Fields: Subfields: Description:
User message The Regenerator Section Trace String is a user de- (ASCII) fined message ASCII (sixteen bytes =128bits long)Expected: The ASCII string or fixed byte to be compared with
received J0 in RSOH. If mismatch, AIS will beinserted if the Insert AIS when trace mismatchbox is checked. The Expected field normally con-tains the same values as the Trace string in the Pathtrace property sheet at the transmit end of the path.
Received: The ASCII string or fixed byte in received J0 inRSOH.
Status: The status of the Regenerator Section Trace:• OK: Expected and received Regenerator
Section Trace are identical.• RS-TIM alarm: (Regenerator Section Trace
Identifier Mismatch) Mismath betweenexpected and received RS Trace.
• LOF error: Loss of frame alarm on receivedSTM-1 signal. Thus, J0 is not available. Alarmstatus, OK or RS-TIM alarm will be latched.
• CRC error: CRC error in received RegeneratorSection Trace. (Only in User Message mode)
• Invalid: Not valid User Message received.
RF ID: (The RF ID functionality is only available at theRadio node)
Not used/Used: RF_ID MS3 bit on/offExpected: The value to be compared with the RF ID byte in
the received SOH. If mismatch, AIS will be in-serted if the Insert AIS when RF ID mismatchbox is checked. The Expected field normallycontains the same values as the RF ID value in thePath Trace property sheet at the transmit end ofthe path.
Received: The received RF ID value.Status: The status of the RF ID:
• OK: Expected and received RF ID values areidentical.
• RF-ID alarm: Mismatch between expected andreceived RF ID values.
• Invalid: Not valid RF ID value received.
176 B4008 Rev. M
CityLink
Figure VII-19 Path Trace Configuration Sheet
3.3 Path Trace(For advanced users)The Path Trace functionality and the AIS (Alarm Indicator Signal) function-ality are used to test that the received STM-1 frames are the frames we wantto receive (correct routing, frequency alignment. . . . ). This is done by eitherinserting a fixed byte or an user defined ASCII sting in the J0 slot in the RSOH,or a two bit RF ID symbol at the transmit end. This is done from the path tracesheet. The RF ID functionality is only available at the Radio side. The radiothat receives the STM-1 frames must have the same Trace string (J0) or RFID defined in the AIS insert sheet. If there is a mismatch, an AIS can beinserted. An AIS can also be inserted if the HBER threshold is exceeded.
The Path Trace configuration sheet can be opened from the Configurationcontext menu of both the Transmission Radio and Line Tx nodes in theExplorer view. The sheet can also be invoked by selecting (highlighting) theone of the Transmission Radio and Line Tx nodes in the Explorer view andthen selecting Edit Path Trace from the Configuration menu.
B4008 Rev. M 177
Configuration with NEW-Configurator
Fields: Subfields Description:Regenerator sectiontrace string
Enabled When checked the specific TraceString is sent in the J0 byte.
Fixed byte The Regenerator Section TraceString is one byte ( =8bit) long.
User message The Regenerator Section Trace (ASCII) String is a user defined message
ASCII (sixteen bytes =128bits long)Trace string Specifies the data (Fixed byte or
User Message) to be inserted intothe J0 byte.
RF IDNot used/Used RF_ID MS3 bit on/off
Two bit combination.
178 B4008 Rev. M
CityLink
4.0 Equipment Node4.1 Network Routing
The active and initial routing tables map incoming messages that areaddressed to other NEs, to different communication ports.
The active routing table is used by the IDU to route messages to other NEs,using the best path detected. The IDU regularly searches for connectedNEs through all enabled communication ports to detect any changes in thenetwork topology. This table is initialised with the initial routing entrieswhen the IDU is rebooted (and when the initial routing table is configuredby the user) and then evolves towards an optimal routing table.
The initial routing table is used after the IDU has been booted. This tableis used as a starting point for the routing mechanism, and will thus, ifproperly set, decrease the time the NE uses to create a sufficient activerouting table. Initial routing entries can be manually added and activerouting entries can be copied to the initial table.
The Routing Table configuration sheet can be opened from the Config-uration context menu of the Equipment node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the Equipment nodein the Explorer view and then selecting Edit Routing Table from theConfiguration menu.
B4008 Rev. M 179
Configuration with NEW-Configurator
Figure VII-20Routing Table Configuration Sheet,Active Tab (top) and Initial Tab (bottom)
180 B4008 Rev. M
CityLink
Fields: Description:Auto/Manual If Auto, the router may update the entry in the active
routing table automatically based on shortest path/lowest weight. If Manual, the entry is never changed bythe router and fixed route configuration is used.
Section The Section number of the addressed NE (1-128).NE The NE address of the destination NE. If this number is
255, section routing is used. That means that this routingentry is used for all NEs in the specified section.Possible values: 1...62 (and broadcast address 255).
Port The communication port of which the messages are to berouted through. Possible values:• NI1• NI2• DCC Line• DCC Radio• OSI TP4 tunnel 1 (Server)• OSI TP4 tunnel 2 (Server)• OSI TP4 tunnel 1 (Client)• OSI TP4 tunnel 2 (Client)• TCP/IP tunnel 1 (Server)• TCP/IP tunnel 2 (Server)• TCP/IP tunnel 1 (Client)• TCP/IP tunnel 2 (Client)
Weight A computed weight that gives an indication of thecommunication capacity to the destination networkelement. A high number denotes a longer response time.
Buttons:Add: Displays the Add Routing Entry dialog box where a new
initial routing entry can be configured.Edit: Displays the Edit Routing Entry dialog box where the
selected initial routing entry can be configured.Delete: Deletes the selected routing entries.Add to static: Copies the selected routing entries to the initial routing
table.
B4008 Rev. M 181
Configuration with NEW-Configurator
4.2 IP Routing
Static RoutesMaximum 20 static routes can be configured on a Nera OSPF router.
Active RoutesAn Nera OSPF router supports approximately 200 active routes.
OSPF areasIt is not recomended to have more than 25 OSPF routers per OSPF area.Each area may export up to 8 address ranges.
Fixed configuration optionsThe Nera OSPF implementation is not a dedicated router implementation andas such some parameters that would normally be configurable are fixed. Forinteroperability with other equipment it is however sometimes important thatthe configuration of external equipment match these values.
Name ValueInject default route into stub area YESRouter dead interval 40 secHello interval 10 secRetransmit delay 1 secRetransmit interval 5 secAuthentication NO
LimitationsThis implementation supports a basic implementation of OSPF v.2 (RFC2823). It does not support virtual links and MD5 authentication.
Other optionsThis implementation supports a rudimentary mechanism for distribution ofstatic and RIP2 routes. The implementation also supports exporting routesto RIP2.
182 B4008 Rev. M
CityLink
Figure VII-21 IP Routing Configuration Sheet,General Settings
4.2.1 General SettingsThe general settings page allows the user to control the general use of theOSPF and RIP 2 protocols for the selected NE. Enabling of protocols onspecific interfaces are performed in the Rip Interfaces and OSPF Interfacesproperty pages.
B4008 Rev. M 183
Configuration with NEW-Configurator
Property page controls:
OSPF Protocol: Select parameter settings for OSPF routing protocol.Enable: Enables the NE to handle OSPF routing.Redistribute RIP: Allows OSPF to redistribute routing
information from RIP v2 routingprotocol.
Redistribute Static: Allows OSPF to redistribute staticrouting information.
Default Cost: Setting of default cost value used forOSPF protocol.
The “Redistribute” options allow the OSPF protocol to passthe routing information of other routing protocols.For information to be passed between the OSPF and RIPprotocols, the current NE must have both protocols enabled.
RIP Protocol: Select parameter settings for RIP routing protocol.Enable: Enables the NE to handle RIP routing.Redistribute OSPF: Allows RIP to redistribute routing infor-
mation from OSPF routing protocol.Redistribute Static: Allows RIP to redistribute static routing
information.Default Metric: Setting of default metric value used for
RIP protocol.
The “Redistribute” options allow the RIP protocol to pass therouting information of other routing protocols.For information to be passed between the OSPF and RIPprotocols, the current NE must have both protocols enabled.
IP Configurable List of interfaces available on the current NE for the OSPFInterfaces: and RIP protocols (IP enabled interfaces).
Interfaces may be enabled for IP in the Communication Portspage for the specific interface (e.g. NI interface on CityLink).
184 B4008 Rev. M
CityLink
4.2.2 Active RoutesMonitor active routes for current NE from this page.
Figure VII-22 IP Routing Configuration Sheet, Active Routes
B4008 Rev. M 185
Configuration with NEW-Configurator
4.2.3 Static RoutesEdit static routes regarding IP Routing using this page.
Figure VII-23 IP Routing Configuration Sheet, Static Routes
Property page controls:
Add: Add a new static route to the list using the appearing dialog.Edit: Select a row and press ‘Edit’ to open the ‘Edit Static Route’ dialog.
In this dialog the settings for the selected route may be changed.Delete: Deletes the selected row(s) from the list.
Note! Changes to the Static Routes are not transferred to the NE before ‘Set’is pressed.
186 B4008 Rev. M
CityLink
4.2.4 RIP InterfacesEdit RIP Interfaces for current NE from this page.
Note!In order to edit the ‘RIP areas’ settings, the RIP protocol must be disabledin the General Settings page.
Figure VII-24 IP Routing Configuration Sheet, RIP Interfaces
Property page controls:Add: Add a new RIP interface to the list using the appearing dialog.Edit: Select a row and press ‘Edit’ to open the ‘Edit RIP Interface’ dialog.
In this dialog the settings for the selected interface may bechanged.
Delete: Deletes the selected row(s) from the list.
Note! Changes to the RIP Interfaces are not transferred to the NE before ‘Set’is pressed.
B4008 Rev. M 187
Configuration with NEW-Configurator
4.2.5 OSPF InterfacesEdit OSPF Interfaces for current NE from this page.
Note!In order to edit the ‘OSPF Interfaces’ settings, the OSPF protocol must bedisabled in the General Settings page.
Figure VII-25 IP Routing Configuration Sheet, OSPF Interfaces
Property page controls:Add: Add a new OSPF interface to the list using the appearing dialog.Edit: Select a row and press ‘Edit’ to open the ‘Edit OSPF Interface’
dialog. In this dialog the settings for the selected interface may bechanged.
Delete: Deletes the selected row(s) from the list.
Note! Changes to the OSPF Interfaces are not transferred to the NE before‘Set’ is pressed.
188 B4008 Rev. M
CityLink
4.2.6 OSPF AreasEdit settings for ‘OSPF areas’ for current NE from this page.
Note!In order to edit the ‘OSPF Areas’ settings, the OSPF protocol must bedisabled in the General Settings page.
Figure VII-26 IP Routing Configuration Sheet, OSPF Interfaces
Property page controls:Add: Add a new OSPF area to the list using the appearing dialog.
Note! Use ‘Edit’ dialog to add new network ranges to existing areas.Edit: Select a row and press ‘Edit’ to open the ‘Edit OSPF Area’ dialog.
In this dialog the settings for the area which the row belongs to maybe changed.
Delete: Deletes the selected row(s) from the list.If a network range row is selected, only the network range is deleted.In all other cases, the entire area is deleted.
Note! Changes to the OSPF areas are not transferred to the NE before ‘Set’is pressed.
B4008 Rev. M 189
Configuration with NEW-Configurator
4.3 Communication Ports4.3.1 DCC (Data Communication Channel)
The CityLink DCC (Data Communication Channel) is used to communicatebetween the Supervisory Unit of the Network Element and Supervisory Unitsof other Network Elements through the SOH of the STM-1 traffic.
There are two DCC ports. DCC Line at the line side and DCC Radio at the radioside. The DCC Radio is always enabled. Nera Stack will always be enabledat DCC Radio.
The Communication Ports configuration sheet can be opened from theConfiguration context menu of the Equipment node in the Explorer view.Press the DCC tab to view/change the DCC settings. The sheet can alsobe invoked by selecting (highlighting) the Equipment node in the Explor-er view and then selecting Edit Communication Ports from theConfiguration menu.
Fields: Choices: Description:
Figure VII-27 DCC Tab in Communication Ports Configuration Sheet
190 B4008 Rev. M
CityLink
Enabled Switches the DCC communication portson/off.
Channel: The Channel where the DCC areinserted in the SOH.
Ch. 1-Ch XX CityLink has only one channel. Thisfield will always be ‘Ch. 1’ at CityLink.
DirectionLine DCC Line is inserted the line side of the
radio.Radio DCC Radio is inserted the radio side of
the radio.Timeslot: Shows which timeslot in the SOH the
DCC channels use. The user can changethe used timeslot by pressing SOH. TheSDH Frame Section Overhead Dialogbox will appear.
StackNera NERA Stack.
Nera stack is always enabled on theradio side (DCC Radio).
QECC QECC StackTCP/IP TCP/IP Stack
LAPD Data link layer for the QECC protocol.For more information refer to ITU-TG.784 and ITU-T Q.921.
Network side Server for the LAPD requests.User side Client for the LAPD requests.
PPP: (Point to Point Protocol) Data linklayer for the TCP/IP protocol.(currently not implemented)
Active mode (currently not implemented)Demand dial (currently not implemented)Direct mode (currently not implemented)Passive mode (currently not implemented)
B4008 Rev. M 191
Configuration with NEW-Configurator
4.3.2 NI (Network Interface)The CityLink NI (Network Interface) ports (NI-1 and NI-2) are used to connectthe Supervisory Unit of the Network Element to Supervisory Units of otherNetwork Elements. The NI ports on the front panel of the CityLink IDU areused to connect the Network Elements. The NI ports can be set to a varietyof different configurations.
The NI 2 port, in the CityLink Radio, can be Enabled only if the Ethernetfunction is Disabled, and vice versa.
The Communication Ports configuration sheet can be opened from theConfiguration context menu of the Equipment node in the Explorer view.Press the NI tab to view/change the NI settings. The sheet can also beinvoked by selecting (highlighting) the Equipment node in the Explorerview and then selecting Edit Communication Ports from the Config-uration menu.
Figure VII-28 NI Tab in Communication Ports Configuration Sheet
192 B4008 Rev. M
CityLink
Fields: Choices: Description:Enabled Enables the NI portFunction CityLink The functionality of the NI port.
NL29x NI The baud rate and stack areNL29x Qx grayed/whitened to indicate whichPDH Synchronous settings are necessary for thePDH Asynchronous different functionalities.V.11 contra dir masterV.11 contra dir slaveV.11 co dirQ1 V.11NL29x V.11 contradir slave
Baudrate The baud rate (symbols pr. second)of the NI port. If the field is grayed,no baud rate is necessary to set.
1200 to 200000 BaudStack
Nera NERA Stack.OSI OSI Stack
LAPD Data link layer for the QECCprotocol. For more informationrefer to ITU-T G.784 and ITU-TQ.921.
Network side Server for the LAPD requests.User side Client for the LAPD requests.
PPP: (Point to Point Protocol) Data linklayer for the TCP/IP protocol.(currently not implemented)
Active mode (currently not implemented)Demand dial (currently not implemented)Direct mode (currently not implemented)Passive mode (currently not implemented)
B4008 Rev. M 193
Configuration with NEW-Configurator
Fields: Choices: Description:Baudrate: 1200 - 115200 Baudrate. The default baudrate is 115200.
4.3.3 LCTThe LCT port is the serial port (RS-232) that can be used to communicate witha PC executing NEW-NMS. In this sheet the baud rate of the LCT port canbe changed.
WARNING!If you are communicating with the NE through the LCT (Serial) port and youchange the LCT baud rate you will loose contact with the NE until youconfigure the NEW-NMS communication settings to the same baud rateas the NE baud rate.
The Communication Ports configuration sheet can be opened from theConfiguration context menu of the Equipment node in the Explorer view.Press the LCT tab to view/change the LCT settings. The sheet can also beinvoked by selecting (highlighting) the Equipment node in the Explorerview and then selecting Edit Communication Ports from the Config-uration menu.
Figure VII-29 LCT Tab in Communication Ports Configuration Sheet
194 B4008 Rev. M
CityLink
4.3.4 EthernetIn the CityLink Radio the Ethernet port can be Enabled only if the NI 2 portis Disabled, and vice versa. See chapter 4.3.2.
The Communication Ports configuration sheet can be opened from theConfiguration context menu of the Equipment node in the Explorer view.Press the Ethernet tab to view/change the Ethernet settings. The sheet canalso be invoked by selecting (highlighting) the Equipment node in theExplorer view and then selecting Edit Communication Ports from theConfiguration menu.
Fields: Choices: Description:Enabled Toggles Ethernet on/offStack OSI TP4 OSI Stack
TCP/IP TCP/IP Stack. Must be selected if IPTunneling is enabled.
Figure VII-30 Ethernet Tab in Communication Ports Configuration Sheet
B4008 Rev. M 195
Configuration with NEW-Configurator
4.3.5 IP SettingsThe IP Settings sheet lets you view the IP address of the NE and configurethe subnet mask and default gateway. The IP address can be set in theElement Id property sheet.
Fields: Description:IP address Shows the Internet Protocol (IP) address of the NE.Subnet mask Type the Subnet Mask number obtained from your
network administrator. This number, combined withthe IP address, identifies which network your NE is on.
Default gateway For each adapter, type the correct IP address of thedefault gateway used for forwarding packets to othernetworks or subnets. This address should be providedby the network administrator and is required for nodeson internetworks. If this is not provided, IP functionalitywill be limited to the local subnet unless a route isspecified with the TCP/IP route command.
Figure VII-31 IP Settings Tab in Communication Ports Configuration Sheet
The Communication Ports configuration sheet can be opened from theConfiguration context menu of the Equipment node in the Explorer view.Press the IP Settings tab to view/change the NI settings. The sheet canalso be invoked by selecting (highlighting) the Equipment node in theExplorer view and then selecting Edit Communication Ports from theConfiguration menu.
196 B4008 Rev. M
CityLink
4.3.6 IP TunnelingA connection can be set up between two NEs through another network,using the Internet Protocol. This is called IP Tunneling. Two connections,IP Tunnel 1 and IP Tunnel 2, can be configured. Ethernet must be enabledwith TCP/IP Stack in order to use IP tunnels. Internet Protocol (IP)-address, Section address and NE address are used for set up of IP tunnelsto other NEs. The IP tunnel must only be set up at one side of the tunnel.
The Communication Ports configuration sheet can be opened from theConfiguration context menu of the Equipment node in the Explorer view.Press the IP Tunneling tab to view/change the IP Tunneling settings. Thesheet can also be invoked by selecting (highlighting) the Equipment nodein the Explorer view and then selecting Edit Communication Portsfrom the Configuration menu.
Fields: Choices: Description:Enabled On/Off Toggles IP Tunneling on/off.Remote section address The section address of the NE addressed
through the IP tunnel.Remote NE address The NE address of the NE addressed
through the IP tunnel.Remote IP address The Internet Protocol (IP) address of
the NE addressed through the IP tunnel.
Figure VII-32 IP Tunneling Tab in Comm. Ports Configuration Sheet
B4008 Rev. M 197
Configuration with NEW-Configurator
4.3.7 OSI TP4 TunnelingA connection can be set up between two NEs through another network,using the OSI protocol. This is called OSI Tunneling. Two connections,OSI TP4 Tunnel 1 and OSI TP4 Tunnel 2, can be configured. Ethernet mustbe enabled with OSI Stack in order to use OSI TP4 Tunneling.Network Service Access Point (NSAP)- address, Section address and NEaddress are used for set up of IP tunnels to other NEs.
The Communication Ports configuration sheet can be opened from theConfiguration context menu of the Equipment node in the Explorer view.Press the OSI TP4 Tunneling tab to view/change the OSI TP4 Tunnelingsettings. The sheet can also be invoked by selecting (highlighting) theEquipment node in the Explorer view and then selecting Edit Com-munication Ports from the Configuration menu.
Fields: Choices: Description:Enabled: On/Off Toggles OSI Tunneling on/offRemote section address: Shows the section address of the NE
addressed though OSI TP4 TunnelRemote NE address: Shows the SU address of the NE
addressed though OSI TP4 TunnelRemote NSAP address: 0 to 20 bytes
Figure VII-33 OSI TP4 Tunneling Tab in Comm. Ports Configuration Sheet
198 B4008 Rev. M
CityLink
4.4 LoopingThe loop settings are divided into five categories: Main traffic looping,2Mbit/s Wayside traffic looping, 64kbit/s looping, 21x2Mbit/s looping andDS3/E3 looping.
4.4.1 Main LoopingThe Looping configuration sheet can be opened from the Configurationcontext menu of the Equipment node in the Explorer view. Press theMain tab to view/change the Main looping settings. The sheet can also beinvoked by selecting (highlighting) the Equipment node in the Explorerview and then selecting Edit Looping from the Configuration menu.
Figure VII-34 Looping Configuration Sheet
B4008 Rev. M 199
Configuration with NEW-Configurator
Fields: Description:Loop buttons: One button for each loop where the arrow indicates
which way the signal is looped. The colour of the looparrows describes the status of the loop:Blue: The status of the loop is unknown. Loop informa-tion has not been retrieved from the NE, or a loop messagehas just been sent to the NE and the GUI (Graphical UserInterface) is waiting for a response from the NE. (Theloop settings have not been confirmed by the NE). Notethat the loop cannot be toggled when the status is unknown.Black: The loop is off (inactive)Red: The loop is on (active)
Loops will be Displays the time of which all main traffic loops in the NEautomatically will be cleared. This time is set by the user when activatingcleared after: a loop.
The different main traffic loops (from left to right in Figure 34):• 4. SORP, LT output to LR input loop, far-end (IDU)• 1. SORP LR output to LT input loop, near-end (IDU)• 14. IF loop, near-end (IDU)• 15. IF loop, near-end (ODU)• 16. RF loop, near-end (ODU)
Buttons:Close: Closes the property sheet.Help: Press this button to get help on the current property sheet page. For
help on an item, click at the top of the dialog box, then click the item.
200 B4008 Rev. M
CityLink
4.4.2 64 Kbit/s LoopingThe Looping configuration sheet can be opened from the Configurationcontext menu of the Equipment node in the Explorer view. Press the 64Kbit/s Looping tab to view/change the looping settings. The sheet canalso be invoked by selecting the Equipment node in the Explorer view andthen selecting Edit Looping from the Configuration menu.
Figure VII-35 Looping Configuration Sheet. 64kbit/s Tab
B4008 Rev. M 201
Configuration with NEW-Configurator
Fields:Loop buttons: One button for each loop where the arrow indicates
which way the signal is looped. The colour of the looparrows describes the status of the loop:••••• Blue: The status of the loop is unknown. Loop informa-tion has yet not been retrieved from the NE, or a loopmessage has just been sent to the NE and the GUI iswaiting for a response from the NE. (The loop settingshave not yet been confirmed by the NE). Note that theloop cannot be toggled when the status is unknown.• • • • • Black: The loop is off (inactive)• • • • • Red: The loop is on (active)• • • • • Grey: The corresponding 64kbit/s channel is not enabled.
The different 64Kbit/s loops: (Figure VII-35 describes the loops)• 40. 64Kbit/s G.703 (near end)• 41. 64Kbit/s G.703 (far end)• 42. 64Kbit/s V.11 (near end)• 43. 64Kbit/s V.11 (far end)
Buttons:Close: Closes the property sheet.Help: Press this button to get help on the current property sheet page. For
help on an item, click at the top of the dialog box, then click the item.
202 B4008 Rev. M
CityLink
4.4.3 2 Mbit/s Wayside LoopingThe Looping configuration sheet can be opened from the Configurationcontext menu of the Equipment node in the Explorer view. Press the 2Mbit/s Wayside tab to view/change the looping settings. The sheet canalso be invoked by selecting (highlighting) the Equipment node in theExplorer view and then selecting Edit Looping from the Configura-tion menu.
Figure VII-36 Looping Configuration Sheet, Wayside Tab
B4008 Rev. M 203
Configuration with NEW-Configurator
Fields:Loop buttons: One button for each loop where the arrow indicates
which way the signal is looped. The colour of the looparrows describes the status of the loop:••••• Blue: The status of the loop is unknown. Loop informa-tion has yet not been retrieved from the NE, or a loopmessage has just been sent to the NE and the GUI iswaiting for a response from the NE. (The loop settingshave not yet been confirmed by the NE). Note that theloop cannot be toggled when the status is unknown.• • • • • Black: The loop is off (inactive)• • • • • Red: The loop is on (active)• • • • • Grey: The corresponding 2Mbit/s channel is not enabled.
The different wayside loops: (Figure VII-36 describes the loops)• 30. Wayside near end loop.• 32. Wayside far end loop.
204 B4008 Rev. M
CityLink
PRBS Settings:PRBS Generator: Generates a PRBS signal that can be inserted into the
transmit direction of the wayside channel.Arrow buttons: Press a button to insert the PRBSsignal from the generator to the wayside channel.There is one button for normal PRBS insert and onebutton for inverted PRBS insert. Red=enabled,black=disabled, blue=unknown status,grey=wayside disabled.
PRBS Check: Counts PRBS errors (An error is detected when thesignal differs from the expected PRBS signal).Errors can be counted at the receive direction of thewayside channel.Arrow buttons: Press a button to enable the errordetection for the desired traffic direction. There isone button for normal PRBS check and one buttonfor inverted PRBS check. Red=enabled,black=disabled, blue=unknown status,grey=wayside disabled.Count: The total number of deviations detectedbetween the received signal and expected PRBSsignal.Rate: The number of deviations detected betweenthe received signal and expected PRBS signal persecond.Reset button. Resets the cumulative counter.Status:
· OK: Error check is valid.· 2Mbit/s Wayside disabled: Wayside channelis not enabled (See the 2Mbit/s Wayside propertysheet).· Counter overflow: The error check is not validbecause the counter has exceeded its limit (=232)and wrapped around.
Sync loss: The error check is not valid due to syncloss on the PRBS sequence.
Buttons:Reset: Resets the PRBS Counter (includes the PRBS Rate)Close: Closes the property sheet.Help: Press this button to get help on the current property sheet page.
For help on an item, click at the top of the dialog box, thenclick the item.
B4008 Rev. M 205
Configuration with NEW-Configurator
4.4.4 21x2Mbit/s Looping (IDU: EMDK42A, 21x2Mbit/sExtension board: 2NCS635A)It is possible to set loops on each individual dropped 2Mbit/s. These loopsare further explained later in this chapter. It is only possible to set one kindof loop at the time on a specific 2Mbit/s tributary.
The Looping configuration sheet can be opened from the Configurationcontext menu of the Equipment node in the Explorer view. Press the21x2Mbit/s tab to view/change the tributary looping settings. The sheetcan also be invoked by selecting (highlighting) the Equipment node in theExplorer view and then selecting Edit Looping from the Configura-tion menu.
Figure VII-37 Looping Configuration Sheet, 21x2Mbit/s Tab
206 B4008 Rev. M
CityLink
Fields: Description:2Mbit/s The physical port number on the 21x2Mbit/s tributary
board.Loop type The user can select between three different loops.
Legal values are:• None• 2Mbit-In → 2Mbit-Out Near End• TMX → DXC Near End• 2Mbit-Out → 2Mbit-In Far End
Remaining time This is a status field for the remaining time the loopwill be present. When the time has expired, i.e. theloops is switched off, this field will be set to Loopcleared.
ON/OFF This column will contain cells that functions as check-boxes. If the user clicks a cell that isn’t checked, aLoop Timer dialog will be launched (see Figure VII-38). The user can set the duration of the loop from thisdialog. If the Loop type is None for a specific loopitem, the user can’t check this loop item’s checkbox.
Note: If the user, by means of the Drop or Continue dialog, removes anyof the tributaries in the list above, they will automatically be removedfrom the list! This means that the number of loop items in the list (eightin the figure above) will not be constant, but will be the same as in theDrop or Continue dialog.
Figure VII-38 The Loop Timer Dialog Box
B4008 Rev. M 207
Configuration with NEW-Configurator
To change the settings:1 First, double-click the desired cell in the Looping type column. Acombobox with the available loops will be shown over the cell.2 Select a looping type from the combobox’s drop down list. Click
anywhere outside the cell in question to apply the setting. 3 Click on the ON/OFF checkbox of the loop item in question. A Loop
Timer dialog will be launched (see Figure VII-38).4 In the Loop Timer dialog set the desired expire time for the loop item
in question and close this dialog by clicking the OK button.5 The checkbox of the loop item in question will now have been checked.
The Remaining time cell of the loop item in question will be updatedevery 5th second with the remaining time of the loop.
6 To clear a loop just click the checked checkbox of the loop item inquestion.
Note: Every altered setting to any item in the list will be applied thetarget immediately.
4.4.5 DS3/E3 LoopingThe DS3/E3 card includes three PDH ports, each of which supports looping.The card supports Far End Loop, Near End Loop, PRBS insertion and PRBSverification. The loops are available when the PDH Ports on the DS3/E3 cardhave been configured to add or drop traffic.
A PRBS signal can be inserted on all three PDH ports instead of the regulartraffic. The incoming PRBS signal can then be checked in order to verify thequality of the communication path. To check the quality of the signal, a PRBScounter is configured to count the errors on one of the PDH Ports in one ofthe DS3/E3 directions. An error is detected when the signal differs from theexpected PRBS signal.
The DS3/E3 card has one PRBS generator that can be muxed into eitherinbound or outbound direction on one or more ports simultaneously. ThePRBS generator can be inverted. For E3 the PRBS polynom is 223 - 1 and forDS3 the PRBS polynom is 215 -1. The PRBS checker is available at one of thePDH ports in either inbound or outbound direction and can also checkinverted PRBS signals.
208 B4008 Rev. M
CityLink
The Looping Configuration Property sheet can be opened from the Config-uration context menu of the Equipment node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Equipment node in theExplorer view and then selecting Edit Looping from the Configurationmenu .
Property page controls:Loop buttons: One button for each loop where the arrow indicates which way
the signal is looped. The colour of the loop arrows describesthe status of the loop:Blue: The status of the loop is unknown. Loop information
has not been retrieved from the NE, or a loop messagehas just been sent to the NE and the GUI is waiting fora response from the NE. (The loop settings have notbeen confirmed by the NE). Note that the loop cannotbe toggled when the status is unknown.
Black:The loop is off (inactive)Red: The loop is on (active)
Figure VII-39 Looping Configuration Sheet, DS3/E3
B4008 Rev. M 209
Configuration with NEW-Configurator
PRBS Generator: Generates a PRBS signal that can be inserted into oneor both directions of the PDH Port.Arrow buttons: Press a button to insert the PRBS
signal from the generator to the PDHPort. Red=enabled, black=disabled,blue=unknown status.
Inverted: When checked, the generated PRBSsignal is inverted.
PRBS Check: Counts PRBS errors. Errors can be counted on one ofthe PDH ports in one of the DS3/E3 directions at a time.Arrow buttons: Press a button to enable the error
detection for the desired trafficdirection. Red=enabled, black=disabled, blue=unknown status.
Inverted: When checked, an inverted PRBSsignal is expected.
Count: The total number of deviationsdetected between the receivedsignal and expected PRBS signal.
Rate: The number of deviations detectedbetween the received signal andexpected PRBS signal per second.
Reset button: Resets the cumulative counter.Status: • OK: Error check is valid.
• Counter overflow: The error checkis not valid because the counterhas exceeded its limit (=232) andwrapped around.
• Sync loss: The error check is notvalid due to sync loss on the PRBSsequence.
Message info field: Displays status of data exchange between GUI andNE. Loop status is updated regularly (5 secondinterval) as long as this property sheet is open.
210 B4008 Rev. M
CityLink
Fields: Description:Article code: The Article CodeSerial no: The Serial number.HW revision: Hardware revisionMAC address: The Media Access Control address of
the NE.Production date: The date when the article was produced.Test date: The date when the article was tested.FAT date: The date when the Factory Acceptance
Test was found to be satisfactory.
4.5 In Door Unit (IDU)4.5.1 IDU Production Data
The IDU production data property sheet shows the production serialnumbers and the production and test dates of the IDU. Only an administra-tor can change the settings.This sheet is also used for calibrating the Optical Line interface. Calibra-tion is only needed when the optical unit is beginning to get old.
The IDU Production Data configuration sheet can be opened from theConfiguration context menu of the IDU node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the IDU node in theExplorer view and then selecting Edit Production Data from theConfiguration menu.
Figure VII-40 IDU Production Data Configuration Sheet
B4008 Rev. M 211
Configuration with NEW-Configurator
4.5.2 64 kbit/s ChannelsTwo 64 kbit/s channels can be inserted into the SOH. Each of the 64 kbit/schannel will occupy one byte of the SOH frame. Press the SOH Frame buttonto select which bytes of the SOH that are used by the 64 kbit/s Channels.One channel is the V.1l. This channel has to be of type V.11 Contra. Theother is the G.703 Channel. This channel can be either G.703 Co orG.703 Contra. Both channels can be retrieved from and inserted into theline and radio side independently.
The 64 kbit/s Channels configuration sheet can be opened from theConfiguration context menu of the IDU node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the IDU node in theExplorer view and then selecting Edit 64 kbit/s Channels from theConfiguration menu.
Figure VII-41 64 kbit/s Channels Configuration Sheet
212 B4008 Rev. M
CityLink
Fields: Choices: Description
Status:Enabled Enables the 64 kbit/s Channel.Disabled Disables the 64 kbit/s Channel.
Type: Choose linecode for 64 kbit/s Channel.V.11 Contra (Channel V.11)G.703 Co (Channel G.703)G.703 Contra (Channel G.703)
Direction: Choose the direction the 64 kbit/s RxChannel should be extracted from.
Line 64 kbit/s Rx is inserted fromline SOH frames.
Radio 64 kbit/s Rx is inserted fromradio SOH frames.
Timeslot: Shows which timeslot in the SOH the64 kbit/s Rx Channel occupy.
B4008 Rev. M 213
Configuration with NEW-Configurator
4.5.3 2 Mbit/s Wayside ChannelA 2 Mbit/s channel can be inserted in the SOH in either line-direction or radio-direction. The 2 Mbit/s channel will occupy 33 bytes (32 bytes data + 1 bytealignment information) of the SOH. Press the SOH Frame button to viewwhich bytes of the SOH that are used by the 2 Mbit/s Wayside Channel. The2 Mbit/s channel uses the Rx and Tx connection at the front panel of the IDU.Rx is received data and Tx is sent data.
The 2 Mbit/s Wayside configuration sheet can be opened from the Configu-ration context menu of the IDU node in the Explorer view. The sheet can also beinvoked by selecting the IDU node in the Explorer view and then selecting Edit
2 Mbit/s Wayside from the Configuration menu.
Figure VII-42 2 Mbit/s Wayside Channel Configuration Sheet
Fields: Options: Description:Status Enabled Enables the Wayside Channel
Disabled Disables the Wayside ChannelDirection Choose the direction the Wayside Rx channel
should be extracted from.Line The Wayside channel is extracted from line
SOH. When the rate is set to DS1, the Linedirection is not available.
Radio The Wayside channel is extracted from radioSOH.
214 B4008 Rev. M
CityLink
Rate Choose the rate of the Wayside channel.This field is only available when the NEsupports DS1 Wayside functionality. If not,the rate is assumed to be E1.
E1 2 Mbit/sDS1 1.5 Mbit/s
Coding Choose the coding of the Wayside channel.This field is only available when the NEsupports DS1 Wayside functionality. If not,the coding is assumed to be of type HDB3.
HDB3 Only available for E1AMI Only available for DS1B8ZS Only available for DS1
Sensitivity This field is only available when the NE isequipped with the DS3/E3 Extension Boardand the DS1 rate is selected
-30dB Only available for DS1-36dB Only available for DS1
Cable Length This field is only available when the NE isequipped with the DS3/E3 Extension Boardand the DS1 rate is selected
133-266 feet266-399 feet399-533 feet533-655 feet-7.5dB CSU-15dB CSU-22dB CSU
Buttons:SOH frame Press this button to view which timeslots in the SOH
the Wayside channel occupies.
B4008 Rev. M 215
Configuration with NEW-Configurator
4.5.4 SOH X-ConnectTwo 64kbit/s (one SOH timeslot) cross-connections can be set up. Thecross-connections bypass the SORP so that the SOH time-slots are sentfrom the Line receive unit directly to the Radio transmit unit.
The SOH X-Connect configuration sheet can be opened from the Config-uration context menu of the IDU node in the Explorer view. The sheet can alsobe invoked by selecting (highlighting) the IDU node in the Explorer view andthen selecting Edit X-Connect from the Configuration menu.
Figure VII-43 SOH X-Connect Configuration Sheet
Fields: Description:Enabled/Disabled Switches SOH X-Connect on/offLine timeslot The time slot to bypass the SORP.Radio timeslot The destination time slot.
216 B4008 Rev. M
CityLink
Fields: Choices: Description:Enabled/Disabled Toggles Error Pulse Output On/OffSource Only one source
at a time.FEC radio The output pin reflects the FEC on
the Viterbi asic.B1 line The output pin reflects the B1 on
the Line Receive side of the SORP.B2 line The output pin reflects the B2 on the
Line Receive side of the SORP.B1 radio The output pin reflects the B1 on the
Radio Receive side of the SORP.B2 radio The output pin reflects the B2 on the
Radio Receive side of the SORP.
4.5.5 Error Pulse OutputFor test purposes.The SORP and Viterbi asics give error pulses when they recognize errors. Thenumber of error pulses per second is a measurement of the quality of thereceived signals. These error pulses can be sent out on the ALM/AUX port.
The Error Pulse Output configuration sheet can be opened from theConfiguration context menu of the IDU node in the Explorer view. The sheetcan also be invoked by selecting the IDU node in the Explorer view and thenselecting Edit Error Pulse Output from the Configuration menu.
Figure VII-44 Error Pulse Output Configuration Sheet
B4008 Rev. M 217
Configuration with NEW-Configurator
4.5.6 Auxiliary Output ConfigurationThe auxiliary output function must be enabled in the Available Functionsproperty sheet (see Chapter 2.2, this Section) to use the function.There are four configurable auxiliary output pins in the ALM/AUX port.The pins are connected to a relay, which can either be controlled manually,or triggered automatically on a user selectable set of alarms.The Auxiliary Output Configuration sheet can be opened from theConfiguration context menu of the IDU node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the IDU node in theExplorer view and then selecting Edit Auxiliary Output from theConfiguration menu.
Figure VII-45 Auxiliary Output Configuration Sheet
Controls: Choices: Description:Output control Manual Control Set the usage of the aux.outputradio buttons or pin. (This will be disabled if the
Alarm Trigger CityLink does not supportalarm triggers.)
Manual relay Closed or Open If the aux. output is set tostatus radio manual control, these buttonsbuttons will be enabled, and can be used
to manually control the state ofthe relay.
218 B4008 Rev. M
CityLink
Controls: Choices: Description:Equipment tree Displays and selects the alarms
available for alarm triggers.This will be disabled if the aux.output is set to manual control.
Alarm trigger list Displays the alarm triggersconfigured. This will be dis-abled if the aux. output is set tomanual control.
Add alarm button Adds the currently selectedalarm in the equipment tree tothe alarm trigger list. If there isno selection, or if the selectedtree node doesn’t correspond toan alarm, nothing happens.Disabled if the output is onmanual control.
Remove Removes the currently selectedalarm button alarm from the alarm trigger list.
Disabled if the output is onmanual control.
Alarm triggered Closed or Open If the aux. output is set to alarmradio buttons triggered control, these buttons
will be enabled, and can be usedto control the state of the relaywhen the alarm conditions areraised.
Buttons:Get: Press this button to retrieve the current settings from the NE.
(The settings are automatically retrieved from the NE when thedialog box is opened).
Set: Press this button to update the element with any changes made toany of the Auxiliary Output pages in the dialog box.
Close: Closes the dialog box.Help: Press this button to get help on the current property sheet. For help
on an item, click at the top of the dialog box, then click the item.
B4008 Rev. M 219
Configuration with NEW-Configurator
4.5.7 DiagnoseThe Diagnose function retrieves data about memory, boot errors and warnings,boot version and number of resets of the SU of the NE. Press Get to retrieve thedata from the NE. The diagnose tests are performed at IDU reset. (Note that theViterbi decoder and SORP1 are only tested at cold reset)
The Diagnose configuration sheet can be opened from the Configurationcontext menu of the IDU node in the Explorer view. The sheet can also beinvoked by selecting (highlighting) the IDU node in the Explorer view andthen selecting Edit Diagnose from the Configuration menu.
Figure VII-46 Diagnose Configuration Sheet
Module Status CommentsCPLD OK/Not OK A write/read test sequence was performed
at last reset/startup.RTC OK/Low bat/ A write/read test sequence was performed
Not running at last reset/startup.LCD OK/Not OK A write/read test sequence was performed
at last reset/startup.DRAM OK/Not OK A write/read test sequence was performed
at last reset/startup.SRAM OK/Not OK A write/read test sequence was performed
at last reset/startup.Code FLASH OK/Not OK A write/read test sequence was performed
at last reset/startup.Boot FLASH OK/Not OK A write/read test sequence was performed
at last reset/startup.Viterbi Decoder OK/Not OK A write/read test sequence was performed
at last startup.SORP OK/Not OK A write/read test sequence was performed
at last startup.
220 B4008 Rev. M
CityLink
4.5.8 Self TestThe Self Test function uses a two step procedure for testing the IDU. Thefirst test sets a CMI loop, while the second test sets an IF loop. For bothloops, a PRBS is created in the SORP and errors are counted andsynchronization losses are registered as the signal returns from the loops.Press Test to start the Self Test.
WARNING!When performing a Self Test the STM-1 traffic will be destroyed.
The Self Test dialog box can be opened from the Configuration contextmenu of the IDU node in the Explorer view. The dialog box can also beinvoked by selecting (highlighting) the IDU node in the Explorer view andthen selecting Edit Self Test from the Configuration menu.
Figure VII-47 Selt Test Dialog Box
4.5.9 BER ThresholdsThe Viterbi decoder is a component using a Viterbi low complexity algorithmfor decoding/error correcting the received bit-sequence in the NE. TheViterbi error rate is used as a quality measurement for the radio hop.
When the Viterbi error rate exceeds certain values, alarms are generated.The threshold values decide when alarms are generated. The thresholdvalues can be changed by the user.
Alarm Id Default value Alarm severityHBER Indicator for BER > 1e-3 MAJORLBER Indicator for LBER > 1e-6 MINOREW-BER Indicator for EW-BER > 1e-10 WARNING
B4008 Rev. M 221
Configuration with NEW-Configurator
Fields: Choices: Description:HBER 1.0·10-3 - 1.0·10-10 Error bit rate
A Major alarm is generated when the Viterbierror rate exceeds the HBER threshold value.AIS is inserted when the HBER thresholdvalue is exceeded.
LBER 1.0·10-3 - 1.0·10-11 Error bit rateA Minor alarm is generated when the Viterbierror rate exceeds the LBER threshold value.
EW 1.0·10-3 - 1.0·10-12 Error bit rate.A Warning is generated when the Viterbierror rate exceeds the Error Warningthreshold value.
Figure VII-48 BER Threshold Configuration Sheet
Internal proportions: HBER > LBER > EW
The BER Threshold configuration sheet can be opened from the Configu-ration context menu of the Radio node under the IDU node in the Explorer view.The sheet can also be invoked by selecting (highlighting) the Radio nodeunder the IDU node in the Explorer view and then selecting Edit BERThreshold from the Configuration menu.
222 B4008 Rev. M
CityLink
4.5.10 OSI ConfigurationThe OSI configuration has to be set to get OSI traffic on your LAN, routedthrough the Nera network.
4.5.10.1 OSI Line CodingChoose the scheme for the encoding of the binary data stream in thecommunication channels. The two ends of a communications line must beconfigured with the same Line Encoding in order to communicate!
Figure VII-49 OSI Configuration Sheet, Line Coding Tab
Fields: Description:NI1: The line coding for the NI1 interface. Can be NRZ or NRZI.NI2: The line coding for the NI2 interface. Can be NRZ or NRZI.DCC Line: The line coding for the DCC Line interface.
Can be NRZ or NRZI.DCC Radio: The line coding for the DCC Radio interface.
Can be NRZ or NRZI.
B4008 Rev. M 223
Configuration with NEW-Configurator
4.5.10.2 OSI ParametersConfigure the OSI parameters for the different communication channels.To enable OSI for the different channels, do this at the appropriateCommunication ports configuration page. Link state protocol buffer sizeapply to all channels.
Figure VII-50 OSI Configuration Sheet, Parameters Tab
224 B4008 Rev. M
CityLink
Fields: Subfield: Description:
NSAP Address Area ID Subnet address.Host ID End system address.End Selector Type of service. Always 01.
Link state Transmitted buffer length size of ISprotocol hello-packets.(512-1492 bytes)buffer size
Parameters MTU size Maximum Transmission Unit size.(512-1497 bytes)
Default Metric Cost of path.LAPD Role: Client/Server role
The two ends of a communications linemust be configured with the oppositeroles in order to communicate!
OSI Enabled This control is checked if OSI isenabled for the respective interface.This is set in the NI or DCC Commu-nication Ports Configuration pages
B4008 Rev. M 225
Configuration with NEW-Configurator
4.5.10.3 OSI Routing TableThis page shows the OSI Routing Table contained in the IDU. The listshows Host Id and Metric for all entries in the table. To get an updatedRouting Table, press the Get Button.
Figure VII-51 OSI Configuration Sheet, Routing Table Tab
Fields: Description:Host Id End system address.Metric Cost of path.
226 B4008 Rev. M
CityLink
Figure VII-52 OSI Configuration Sheet, Interface Information Tab
4.5.10.4 OSI Interface InformationThere will be one line in the table for each channel enabled for OSI.
Fields: Description:Id Numbering of interfaces in the networkInterfaceName Network userMedia Type of mediaStatus Indication of connection status (Up or Down)MTU Size Maximum transmission unit size
B4008 Rev. M 227
Configuration with NEW-Configurator
Figure VII-503 Laser Control Configuration Sheet
4.5.11 Laser ControlThe optical port may or may not have implemented Automatic LaserShutdown (ALS). This is a function designed for eye safety purposes,according to ITU-T rec. G.958. When implemented, ALS may be enabledor disabled.
When ALS is not implemented or enabled the laser must be turned on/offmanually.
When ALS is enabled, the laser automatically will restart after a waitingtime period (selectable), when having previously been turned off. (If thesection of operation is not connected or Loss Of Optical Signal from farend is detected, the laser will again be turned off after 2 sec.) The waitingperiod is by default set to 1 minute.
The Laser Control configuration sheet can be opened from the Config-uration context menu of the Optical Line node under the IDU node inthe Explorer view. The sheet can also be invoked by selecting (highlight-ing) the Optical Line node under the IDU node in the Explorer view andthen selecting Edit Laser Control from the Configuration menu.
228 B4008 Rev. M
CityLink
Fields: Buttons: Description:
ALS:Enabled/Disabled Toggles ALS On/OffWaiting Time (1.0 - 5.0 minutes ) Specifies waiting
time before the laser is turned on. Ifsection of operation is connected andoptical signal from far end is present,laser will remain on, if not laser willbe turned off after 2 seconds.
Get Retrieves Laser Control settingsfrom the NE.
Set Sends Laser Control settings to the NE.Restart (2 Seconds) Manually restart the laser for
2 seconds.Restart (90 Seconds) Manually restart the laser for
90 seconds for testing purposes.
ManualControl: (ALS disabled or not implemented)
On Manually turn the laser on.Off Manually turn the laser off.Status: Shows the status of the Laser Unit.
B4008 Rev. M 229
Configuration with NEW-Configurator
4.5.12 IDU Replace Unit WizardThe Replace Unit Wizard simplifies the process of replacing an IDU. Thewizard copies configuration data from “old” IDU to the “new” IDU.
Note:• The NEW program must be directly connected to the LCT port on the
IDU (serial communication).• The “old” NEs configuration data is copied to the “new” IDU,
including Element ID. Thus the addresses of the “new” IDUbecome equal to the addresses of the “old” IDU.
• Available Functions data is not copied. The “new” IDU may haveother optional functions available than the “old” IDU.
The wizard describes each step in the replacement process.
Figure VII-54 The IDU Replace Unit Wizard
230 B4008 Rev. M
CityLink
4.6 Out Door Unit (ODU)4.6.1 Type I ODU4.6.1.1 Frequency Settings
The Duplex Distance between the Rx and Tx band is fixed. The user can setthe Tx frequency by clicking on the frequency slots. Since the duplexdistance is fixed the Rx frequency will be automatically set. The corre-sponding Tx and Rx frequency must be set in the opposite NE.
Note! Dual Frequency - Single Polarisation (DF-SP) requires two chan-nels in order to transmit 2xSTM-1. With this configuration, adjacentchannels can not be used.
NEW NMS/Configurator receives the frequency plan from the NE.When no NE is connected (off-line), no frequency plan will be shown.
The output power is automatically muted when the frequency setting isexecuted.
The Frequency configuration sheet can be opened from the Configura-tion context menu of the ODU node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the ODU node in the Explorerview and then selecting Edit Frequency from the Configurationmenu.
Figure VII-55 Frequency Configuration Sheet
B4008 Rev. M 231
Configuration with NEW-Configurator
Fields: Description:Frequency Select the desired frequency plan. The frequencyplan plan must correspond to your transceiver.Coding The coding function used in the modulator/
demodulator. These coding functions may beselectable depending on frequency plan:TCM (Trellis coded modulation) and TCM + RS(Trellis coded modulation and Reed Solomon).
Modulation The modulation scheme used with this frequencyplan
Data Rate The data rate(s) supported by this frequency plan.The available data rates may also be dependent onradio type, radio software version and coding.
Channel Spacing (MHz) The distance between the channels in this freq-uency plan
Duplex Distance (MHz) The distance between the TX and the RX carrierfrequency.
Innermost Spacing (MHz)The distance between the highest selectable freq-quency in the lower half of the plan and the lowestselectable frequency in the upper half og the plan.
TX Frequency (GHz) The used TX Carrier frequencyRX Frequency (GHz) The used RX Carrier frequencyTX (min) (GHz) TX Lower sideband frequency for this frequency
planTX (max) (GHz) TX Upper sideband frequency for this frequency
planRX (min) (GHz) RX Lower sideband frequency for this frequency
planRX (max) (GHz) RX Upper sideband frequency for this frequency
plan
••••• To change the settings:1. Get the current settings from the Network element by pressing Get. (The
settings are automatically retrieved from the NE when the property-sheetis opened)
2. Alter the settings by clicking the frequency band you want to transmityour TX data. The RX frequency is automatically updated since theduplex Distance is fixed.
3. Press Set to send the changes to the NE.
232 B4008 Rev. M
CityLink
4.6.1.2 ODU Transceiver - Power ConfigurationThe Transceiver Power Configuration sheet lets the user set some OutputPower settings, some RF Input warning thresholds and ATPC settings.
ATPC (Automatic Transceiver Power Control) is a function for effective-ly reducing the interference probability in your network. The output powerfrom the transceiver is automatic controlled. If the regulation loop for theATPC stops functioning, an alarm is generated. This alarm can be delayed.
The output power is automatically muted when the frequency setting isexecuted.
The Power configuration sheet can be opened from the Configurationcontext menu of the ODU node in the Explorer view. The sheet can alsobe invoked by selecting (highlighting) the ODU node in the Explorer viewand then selecting Edit Power from the Configuration menu.
Figure VII-56 Power Configuration Sheet
B4008 Rev. M 233
Configuration with NEW-Configurator
Fields: Denomination: Description:
RF input level dBm The upper threshold value for whenwarning, high to generate an RF input level
warning (Alarm no. 1504)
RF input level dBm The lower threshold value for whenwarning, low to generate an RF input level
warning (Alarm no. 1504)
ATPC dBm Set the power level to use when analarm level ATPC alarm occurs.
ATPC dBm The wanted input level when ATPCreference level is activated.
Mute Mutes the output power. No outputoutput power power is sent.
Maximum dBm Maximum output power foroutput power transmitting
Manual dBm The output power level used whenoutput level ATPC is not activated
ATPC status ATPC Disabled/ Enabled
ATPC mode ATPC can operate in four different modes:Automatic Regulation: The trans-ceiver automatically regulates thetransmitter powerMinimum Output: A min. amount ofpower is used for transmitting.Maximum Output: A max. amount ofpower is used for transmitting.Freeze Output Power: A fixed amountof power is used for transmitting.
ATPC Seconds The ATPC alarm can be delayed fromalarm delay 1 to 15 seconds.
234 B4008 Rev. M
CityLink
Figure VII-57 ODU Production Data Configuration Sheet
4.6.1.3 ODU Production DataThe ODU production data property sheet shows the production serialnumbers and the production and test dates of the ODU. Only an adminis-trator can change the settings.
The ODU Production Data configuration sheet can be opened from theConfiguration context menu of the ODU node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the ODU node in theExplorer view and then selecting Edit Production Data from theConfiguration menu.
Fields: Description:Article code: The article codeSerial no: The serial number.HW revision: Hardware revisionSales order: The purchase order.Production date: The date when the article was produced.Test date: The date when the article was tested.FAT date: The date when the Factory Acceptance Test was
found to be satisfactory.SAT date: The date when the Site Acceptance Test was
found to be satisfactory.
B4008 Rev. M 235
Configuration with NEW-Configurator
4.6.2 Type II ODU4.6.2.1 RF Power
The XCVR Unit provides a set of RF power control functions:• RF input alarm thresholds can be set such that an alarm is raised when
the input level exceeds the upper or lower limits.• ATPC (Automatic Transmitter Power Control) is a function for effec-
tively reducing the interference probability in the network. When ATPCis enabled, the output power from the transmitter is automaticallycontrolled according the received input power on the other side of thehop. The ”ATPC” alarm is generated if the ATPC regulation loop fails.This alarm can be optionally delayed.
• If ATPC is not enabled, the transmitted output level can be set. Thetransmitter can also be muted.
The RF Power property sheet is used to display/configure the RF Powercontrol settings.
Figure VII-58 RF Power Configuration Sheet
236 B4008 Rev. M
CityLink
Fields:Mute output power: When checked the output power is muted.Maximum output level (dBm): The transmitter’s maximum output power.Manual Transmit Output Power (MTPC): ATPC is disabled. Constantmanual output level is used.Automatic Transmit Output Power (ATPC): ATPC is enabled. Outputlevel is automatically adjusted using the specified ATPC settings.Alarm Thresholds:
• RF-INPUT-WARNING, high (dBm): If the RF input level exceedsthis value the ”RF-INPUT-WARNING” alarm is raised.
• RF-INPUT-WARNING, low (dBm): If the RF input level goesbelow this value the ”RF-INPUT-WARNING” alarm is raised.
MTPC:• Manual output level (dBm): The output power used when ATPC is
disabled.ATPC:
• Reference input level (dBm): The desired input level. If ATPC isenabled on the transmitter across the hop, that transmitter will regulateits output power such that the received input level at this receiver isequal to the reference level.
• Default output level (dBm): The output power to be used if the ATPCregulation loop fails. (The ”ATPC” alarm is raised).
• Alarm delay (s): The delay (in seconds) before the ATPC alarm israised after the ATPC regulation loop fails.
Message info field: Displays status of data exchange between GUI andNE.
B4008 Rev. M 237
Configuration with NEW-Configurator
4.6.2.2 Frequency SettingsThe Frequency property sheet displays the frequency settings for thetransceiver unit. Available frequency plans and their parameters are storedin a table in the NEW-NMS database. If the wanted frequency plan cannotbe found in the combo box, please contact Nera for upgrading the databasetable. When frequency data is retrieved from the NE, the data are matchedagainst frequency plans stored in your database system. If a match is foundthe appropriate frequency plan is selected, otherwise a frequency plan canbe selected from the combo box.
To change the frequencies:1. Select a frequency plan from the combo box.2. Select a TX frequency by pressing a button in the frequency plan. The
RX frequency will be calculated from TX frequency and the duplexdistance.
3. Send the new settings to the NE. (Press the Set button in the propertysheet). A message box will be displayed asking whether to apply thecontrary frequencies to the other side of the hop (if the remote NE ispresent in NEW).
Figure VII-59 Frequency Configuration Sheet
238 B4008 Rev. M
CityLink
Fields:Frequency Plan:
• Selected plan: The currently selected frequency plan. The graphicalpresentation of the plan contains channel buttons that can be used to set
the TX and RX frequencies for the selected channel in the list.• Modulation: modulation method: 32TCM, 64TCM or 128 TCM.• Channel spacing: The distance in MHz between two consecutive
channels.• Data rate: STM-1 or STM-0.
Current Setting:• TX frequency (GHz): The Transmitter frequency.• RX frequency (GHz): The Receiver frequency.
Transceiver limits: The frequency band limits of the transceiver.Status: Frequency status:
• OK: Frequency settings are OK.• Frequency shifting: The frequencies are changed on both sides of the
hop. If no connection is established within 10 seconds the frequencieswill be reverted.
Message info field: Displays status of data exchange between GUI andNE.
B4008 Rev. M 239
Configuration with NEW-Configurator
4.6.2.3 DRO TuningThe XCVR Unit’s DRO Tuning property sheet is used to enable and disableDRO Tuning mode for the individual XCVR unit. The tuning of the DROfrequency is performed manually on the XCVR unit. See Chapter 4.6.2.2.
Fields: Description:DRO Tuning Mode:
• Disabled: DRO Tuning mode is disabled for both DRO’s• TX Tuning: Enables DRO Tuning mode for TX DRO• RX Tuning: Enables DRO Tuning mode for RX DRO
Status TX: Displays information concerning frequency lockand screw direction for TX DRO
Status RX: Displays information concerning frequency lockand screw direction for RX DRO
Disabled
Tx tuning
Rx tuning
Figure VII-60 DRO Tuning Configuration Sheet
240 B4008 Rev. M
CityLink
Figure VII-61 DRO Tuning Procedure
Tx Tuning
Rx Tuning
4.6.2.3 DRO Tuning Procedure
B4008 Rev. M 241
Configuration with NEW-Configurator
4.6.2.3.1 Frequency SettingHighlight the actual Transceiver unit to be tuned. Right click and chooseConfiguration and Frequency.
Transceiver Unit Ch1
See Chapter 4.6.2.2 for setting of frequency.
Figure VII-62 Selecting in Explorer View the Transceiver to be tuned
Figure VII-63 Frequency Configuration Sheet
242 B4008 Rev. M
CityLink
4.6.2.3.2 DRO TuningHighlight the actual Transceiver unit to be tuned. Right click and chooseConfiguration and DRO Tuning
Tx tuning
Disabled
Rx tuning
Tx tuning
Select Tx tuning in the DRO Tuning Mode field. Press the Set button.
Figure VII-64 Selecting DRO tuning from the Explorer View
Figure VII-65 DRO Tuning Configuration Sheet
B4008 Rev. M 243
Configuration with NEW-Configurator
The red arrow indicates which way to adjust the DRO. In addition, theAlarm LED on the front of the Transceiver will blink when the DRO mustbe turned clockwise. If the Alarm LED is OFF, the DRO must be turnedcounter-clockwise. When the Alarm LED is ON, the Synthesizer is inlock. Press the Set button to update the window.
Figure VII-66 DRO Tuning Configuration Sheet, Tx tuning
244 B4008 Rev. M
CityLink
Rx Tuning
Disabled
Tx tuning
Rx tuning
Select Rx tuning in the DRO Tuning Mode field. Press the Set button.
Figure VII-67 DRO Tuning Configuration Sheet
B4008 Rev. M 245
Configuration with NEW-Configurator
The red arrow indicates which way to adjust the DRO. In addition, theAlarm LED on front of the Transceiver will blink when the DRO must beturned clockwise. If the Alarm LED is OFF, the DRO must be turnedcounter-clockwise. When the Alarm LED is ON the Synthesizer is in lock.Press the Set button to update the window.
Figure VII-68 DRO Tuning Configuration Sheet, Rx tuning
246 B4008 Rev. M
CityLink
4.6.2.4 Production DataThe different boards/units contain some production information. Thisinformation is displayed in the Production Data property sheet.
Fields: Description:Article code: Uniquely identifies the type of board/unit.Serial no.: The serial number of the board/unit.HW revision: The hardware revision.Production date: When the production process was completed for
this board/unit.Test date: When this product was tested by the factory test-
department.Message info field: Displays status of data exchange between GUI and
NE.
Figure VII-69 Production Data Configuration Sheet
B4008 Rev. M 247
Configuration with NEW-Configurator
4.6.3 Type III ODU4.6.3.1 RF Power
The XCVR Unit provides a set of RF power control functions:• RF input alarm thresholds can be set such that an alarm is raised when
the input level exceeds the upper or lower limits.• ATPC (Automatic Transmitter Power Control) is a function for effec-
tively reducing the interference probability in the network. When ATPCis enabled, the output power from the transmitter is automaticallycontrolled according the received input power on the other side of thehop. The ”ATPC” alarm is generated if the ATPC regulation loop fails.This alarm can be optionally delayed.
• If ATPC is not enabled, the transmitted output level can be set. Thetransmitter can also be muted.
The RF Power property sheet is used to display/configure the RF Powercontrol settings.
Figure VII-70 Power Configuration Sheet
248 B4008 Rev. M
CityLink
Fields:Mute output power: When checked the output power is muted.Maximum output level (dBm): The transmitter’s maximum outputpower.Manual Transmit Output Power (MTPC): ATPC is disabled. Constantmanual output level is used.Automatic Transmit Output Power (ATPC): ATPC is enabled. Outputlevel is automatically adjusted using the specified ATPC settings.Alarm Thresholds:
• RF-INPUT-WARNING, high (dBm): If the RF input level exceedsthis value the ”RF-INPUT-WARNING” alarm is raised.
• RF-INPUT-WARNING, low (dBm): If the RF input level goesbelow this value the ”RF-INPUT-WARNING” alarm is raised.
MTPC:• Manual output level (dBm): The output power used when ATPC is
disabled.ATPC:
• Reference input level (dBm): The desired input level. If ATPC isenabled on the transmitter across the hop, that transmitter will regulateits output power such that the received input level at this receiver isequal to the reference level.
• Default output level (dBm): The output power to be used if the ATPCregulation loop fails. (The ”ATPC” alarm is raised).
• Alarm delay (s): The delay (in seconds) before the ATPC alarm israised after the ATPC regulation loop fails.
Message info field: Displays status of data exchange between GUI andNE.
B4008 Rev. M 249
Configuration with NEW-Configurator
4.6.3.2 Frequency SettingsThe Frequency property sheet displays the frequency settings for thetransceiver unit. Available frequency plans and their parameters are storedin a table in the NEW-NMS database. If the wanted frequency plan cannotbe found in the combo box, please contact Nera for upgrading the databasetable. When frequency data is retrieved from the NE, the data are matchedagainst frequency plans stored in your database system. If a match is foundthe appropriate frequency plan is selected, otherwise a frequency plan canbe selected from the combo box.
To change the frequencies:1. Select a frequency plan from the combo box.2. Select a TX frequency by pressing a button in the frequency plan. The
RX frequency will be calculated from TX frequency and the duplexdistance.
3. Send the new settings to the NE. (Press the Set button in the propertysheet). A message box will be displayed asking whether to apply thecontrary frequencies to the other side of the hop (if the remote NE ispresent in NEW).
Figure VII-71 Frequency Configuration Sheet
250 B4008 Rev. M
CityLink
Fields:Frequency Plan:
• Selected plan: The currently selected frequency plan. The graphicalpresentation of the plan contains channel buttons that can be used to setthe TX and RX frequencies for the selected channel in the list.
• Modulation: modulation method: 32TCM or 128 TCM.• Channel spacing: The distance in MHz between two consecutive
channels.• Data rate: STM-1 or STM-0.
Current Setting:• TX frequency (GHz): The Transmitter frequency.• RX frequency (GHz): The Receiver frequency.
Transceiver limits: The frequency band limits of the transceiver.Status: Frequency status:
• OK: Frequency settings are OK.• Frequency shifting: The frequencies are changed on both sides of the
hop. If no connection is established within 10 seconds the frequencieswill be reverted.
Message info field: Displays status of data exchange between GUI andNE.
B4008 Rev. M 251
Configuration with NEW-Configurator
4.6.3.3 Production DataThe ODU production data property sheet shows the production serialnumbers and the production and test dates of the ODU. Only an adminis-trator can change the settings.
The ODU Production Data configuration sheet can be opened from theConfiguration context menu of the ODU node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the ODU node in theExplorer view and then selecting Edit Production Data from theConfiguration menu.
Figure VII-72 Production Data Configuration Sheet
Fields: Description:Article code: The article codeSerial no: The serial number.HW revision: Hardware revisionSales order: The purchase order.Production date: The date when the article was produced.Test date: The date when the article was tested.FAT date: The date when the Factory Acceptance Test was
found to be satisfactory.SAT date: The date when the Site Acceptance Test was
found to be satisfactory.
252 B4008 Rev. M
CityLink
Figure VII-73 Antenna Data Configuration Sheet
4.6.4 Antenna DataThis sheet shows some main characteristics of the antenna. Only theAntenna code can be altered. The antenna data are stored in a database file.
The Antenna Data configuration sheet can be opened from the Configu-ration context menu of the Antenna node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Antenna node in theExplorer view and then selecting Edit Antenna from the Configura-tion menu.
Fields: Description:Antenna code The antenna code. Unique code for each antenna type.Gain The antenna gain (dB). Gain is a measurement of the
antenna's ability to transform electrical signals toelectromagnetic waves.
Diameter The physical antenna diameter. [meter]Polarization The polarization direction of the antenna.Front/Back ratio Front/Back Ratio. Ratio between the gain in forward
direction and the gain in backward direction.Frequency range The frequency range where the antenna can be expected
to operate successfully.
B4008 Rev. M 253
Configuration with NEW-Configurator
4.6.5 ODU Replace Unit WizardThe Replace Unit Wizard simplifies the process of replacing an ODU. Thewizard copies configuration data from “old” ODU to the “new” ODU.
The wizard describes each step in the replacement process.
Figure VII-74 The ODU Replace Unit Wizard
254 B4008 Rev. M
CityLink
5.0 CityLink ADM5.1 21x2 Mbit/s Extension Board5.1.1 Drop or Continue
The Drop or Continue sheet is used to drop or remove a 2Mbit/sstream(E1). The 21x2Mbit/s extension board supports 21 physical 2Mbit/sports. The user can assign any VC-12, out of the 63 available in the STM-1 structure, to a specific 2Mbit/s port on this board. From which direction thedrop is to be taken must also be configurated.
The Drop or Continue configuration sheet can be opened from theConfiguration context menu of the 21x2 Extension board node in theExplorer view. The sheet can also be invoked by selecting (highlighting)the 21x2 Extension board node in the Explorer view and then selectingEdit Drop or Continue from the Configuration menu.
Note: Even though the 21x2Mbit/s extension board is present in theequipment this dialog will not be shown if the 21x2Mbits/s extensionboard isn’t enabled. This enabling must be done in the SectionTermination dialog which can be opened from the Configurationcontext menu of the Transmission node in the Explorer view.
Figure VII-75 The Drop or Continue Configuration Sheet
B4008 Rev. M 255
Configuration with NEW-Configurator
Fields: Description:Port Number The physical port number on the 21x2Mbit/s extension
board.VC-12 Number The VC-12 number that the 2Mbit/s PDH stream
attached to the Port Number shall be routed to/from(the numbers in the parenthesis is the VC-12 given inKLM notation). It is possible to re-use a given VC-12 aslong as the Direction is different.
Direction This parmeter indicates which direction the VC-12 is tobe routed to/from. It can either be line or radio.
Configured Check this to add a drop or uncheck it to remove a drop.If the checkbox is checked a new dialog will be launched.This dialog is used to select the VC-12 Number and theDirection. This dialog is explained in chapter 4.13.1.1.
Note1: If the user, by means of the VC-12 Selector Dialog, specifies aVC-12 and a direction that is already in use, the setting will not beapplied!Note2: If one attempts to remove a dropped VC-12 that is in use by theclock synchronization in the Section Termination, the removing will berejected!
Buttons:Clear selected item(s): With the mouse one can select one or several
items in the listview. When items are selected,this button will be enabled. Click the button ifyou wish to uncheck the selected items. Mod-ifications that leads to a mismatch between thedialog settings and the settings on the NE willbe tagged with a «dirty» token; *.
Get: Click this button to retrieve the current settingsfrom the NE. Any modifications done to theGUI elements will be lost and the «dirty» tokenwill be removed.
Set: Click this button to send the settings to the NE.Any modifications done to the GUI elementswill be applied the NE and the «dirty» tokenwill be removed.
Close: Click this button to close the property sheet.Help: Press this button to get help on the current
property sheet. For help on an item, click atthe top of the dialog box, then click the item.
256 B4008 Rev. M
CityLink
5.1.1.1 VC-12 SelectorThis dialog is used to select a specific VC-12 from the 63 available in theSTM-1 payload. In addition to the VC-12 number, the direction fromwhich the specific VC-12 is routed to/from is also specified.
This dialog will be launched immediately after the user has checked anitem in the Drop or Continue dialog.
Fields: Description:VC-12 # The VC-12 number. It must be in the interval [1,63].K The first of the three numbers in the KLM number-
ing scheme. The number must be in the interval [1,3].Note that the user can either enter the K numberdirectly or use the up/down buttons to traverse thenumber range.
L The second of the three numbers in the KLM num-bering scheme. The number must be in the interval[1,7]. Note that the user can either enter the Lnumber directly or use the up/down buttons to traversethe number range.
M The third of the three numbers in the KLM number-ing scheme. The number must be in the interval [1,3].Note that the user can either enter the M numberdirectly or use the up/down buttons to traverse thenumber range.
Drop From Line If selected, the VC-12 will be routed to/from the lineinterface of the NE.
Drop From Radio If selected, the VC-12 will be routed to/from theradio interface of the NE.
Figure VII-76 The VC-12 Selector Dialog Box
B4008 Rev. M 257
Configuration with NEW-Configurator
Sub Network SNCP performs path protection switching (calledConnection dedicated protection) which manages all traffics byProtection - SNCP a path. Working traffic is transmitted in one direc-
tion, and protection traffic in opposite directionaround the ring, and traffic is selected at each end ofthe path. So, SNCP supports multiple rings, andoffers suitable solution for access and metro net-work where hub node terminates most varioustraffics. SNCP can also transmit signal to only onedirection, west or east, and the products can be usedas 1+0 Linear ADM mode as well as SNCP mode.
Buttons:OK: Click this button to close the dialog and apply the setting.Cancel: Click this button to close the dialog without applying the setting.
258 B4008 Rev. M
CityLink
5.1.2 PRBS Test - CheckThe PRBS Test - Check sheet is used to set up which of the dropped2Mbit/s tributaries that shall check a given PRBS. Only one 2Mbit/stributary can perform this test at the time.
The PRBS Test - Check configuration sheet can be opened from theConfiguration context menu of the 21x2 Extension board node in theExplorer view. The sheet can also be invoked by selecting (highlighting)the 21x2 Extension board node in the Explorer view and then selectingEdit PRBS Test from the Configuration menu.
Figure VII-77 The PRBS Test Check Configuration Sheet
B4008 Rev. M 259
Configuration with NEW-Configurator
Fields: Description:2Mbit/s The physical port number on the 21x2Mbit/s tributary board.Direction Used to set from which Direction the tributary board shall
check PRBS. To change the setting, the user must double-click the Direction cell in question. When this happens, acombobox will be displayed in the cell and the user canselect a new setting for the cell.
Inverted If this checkbox is checked, it will be assumed that thereceived PRBS is inverted. If not checked, it’s assumed tonot be inverted.
Clear If this checkbox is checked the Count cell will be clearedwhen Set button is clicked.
Check Only one tributary can be set to check PRBS at the time. Thismeans that only one item in the list above can be active at thesame time. In the figure above this is item-1. Item-2 throughitem-8 aren’t active. If e.g. the radio button in item-1 in thefigure is clicked (the one that is active), it will be cleared. Inthis case none of the tributaries will check PRBS.
Count This cell will contain the number of error pulses. It’s a 2^16bits wrap-around counter. If the Status cell is Sync Loss,this counter will not count but instead be set to «—». If theStatus cell is No Sync Loss, this counter will count errors.
Status The status of the counter.
Note: If the user, by means of the Drop or Continue dialog, removes anyof the tributaries in the list above, they will automatically be removedfrom the list!
260 B4008 Rev. M
CityLink
5.1.3 PRBS Test - GeneratorsThe PRBS Test - Generators sheet is used to set up which of the dropped2Mbit/s tributaries that shall generate PRBS. All tributaries can insertPRBS simultaneously.
The PRBS Test - Generators configuration sheet can be opened from theConfiguration context menu of the 21x2 Extension board node in theExplorer view. The sheet can also be invoked by selecting (highlighting)the 21x2 Extension board node in the Explorer view and then selectingEdit PRBS Test from the Configuration menu.
Figure VII-78 The PRBS Test Generators Configuration Sheet
B4008 Rev. M 261
Configuration with NEW-Configurator
Fields: Description:2Mbit/s The physical port number on the 21x2Mbit/s
tributary board.Direction Used to set in which Direction the tributary
board shall insert a PRBS. To change the settingthe user must double click the Direction cell inquestion. When this happens, a combobox willbe displayed in the cell and the user can select anew setting for the cell. Legal values are:
• 2Mbit/s• STM-1• 2Mbit/s & STM-1• Both off
Insert If this checkbox is checked a PRBS will beinserted in the direction(s) specified byDirection.
Insert inverted PRBS If this checkbox is checked all checked tribu-taries in the list will be inserted inverted PRBS.If not checked it’s assumed to not be inverted.
Note: If the user, by means of the Drop or Continue dialog, removes anyof the tributaries in the list above, they will automatically be removedfrom the list!
262 B4008 Rev. M
CityLink
5.1.4 Production Data - 21x2Mbit/s Extension board(2NCS635A)Production data for the 21x2Mbit/s extension board, displayed on a separatepage in the Production Data configuration sheet. Only an administrator canchange the settings.
The Production Data configuration sheet can be opened from the Con-figuration context menu of the IDU- or Switch node in the Explorer view.The sheet can also be invoked by selecting (highlighting) the IDU- orSwitch node in the Explorer view and then selecting Edit ProductionData from the Configuration menu. Then the production data is locatedunder the Tab named 21x2Mbit/s Extension Board.
Fields: Description:Article Code The Article Code of the card/unit.Serial no. The Serial number of the card/unit.HW revision Hardware revision of the card/unit.Production date The date when the article was produced.Test date The date when the article was tested.
B4008 Rev. M 263
Configuration with NEW-Configurator
5.2 DS3/E3 Extension Board5.2.1 DS3/E3 Configuration
The DS3/E3 functionality allows the operator to connect two Virtual Contain-ers (VC) in different ports. The connections are identified by using thebackground colour of the ports together with the KLM address of the virtualcontainer. The background colour of a virtual container identifies the sourceport, while the KLM address identifies the source address.
As an example consider the marked VCs in Figure VII-79. The VC on the LinePort is connected with the VC having a KLM address of 1,2,1 on the RadioPort. While the VC on the Radio Port is connected with the VC having a KLMaddress of 1,1,1 on the Line Port.
SNCP functionality is available on the DS3/E3 Port and is identified with asplit cell.
Traffic Looping is achieved by connecting VCs on the same port and is onlyavailable for the line - and radio port. The DS3/E3 port does not support trafficlooping, but does however support test looping. DS3/E3 looping is onlyavailable on the connected when the port has been configured to add/droptraffic.
The DS3/E3 Configuration sheet can be opened from the Configurationcontext menu of the DS3/E3 Extension Board node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the DS3/E3 ExtensionBoard node in the Explorer view and then selecting Edit DS3/E3 from theConfiguration menu .
264 B4008 Rev. M
CityLink
Buttons:SNCP: Press this button to establish an SNCP connection. The SNCP
functionality will apply to the same virtual container on allports. SNCP is available on the DS3/E3 Port.
Source: To establish a connection, select a virtual container from oneof the ports. Press this button to set the selected container asthe source.
Destination: Select a virtual container from one of the ports and press thisbutton to set the selected container as the destination.
Disconnect: Select a virtual container which already has an establishedconnection. Press this button to remove the connection.
Cancel: Press this button to undo the current operation.Get: Press this button to retrieve the current settings from the
NE. (The settings are automatically retrieved from theNE when the dialog box is opened).
Set: Press this button to send the settings to the NE.Close: Closes the property sheet.Help: Press this button to get help on the current property sheet. For
help on an item, click at the top of the dialog box, then clickthe item.
Figure VII-79 DS3/E3 Configuration Sheet
B4008 Rev. M 265
Configuration with NEW-Configurator
5.2.2 DS3/E3 Frame Structure ConfigurationThe operator may configure the frame structure on the three ports. Each portconsists of three TUG-3’s ( SDH Multiplex Structure). Each TUG-3 containseither a VC-3 structure or a VC-12 structure. The virtual containers on theports are identified using KLM notation:
Figure VII-80 Virtual Containers
266 B4008 Rev. M
CityLink
Figure VII-81 DS3/E3 Frame Structure Configuration Sheet
Buttons:VC-3: Sets the current structure to VC-3.VC-12: Sets the current structure to VC-12.Get: Press this button to retrieve the current settings from the
NE. (The settings are automatically retrieved from theNE when the dialog box is opened).
Set: Press this button to send the settings to the NE.Close: Closes the property sheet.Help: Press this button to get help on the current property sheet. For
help on an item, click at the top of the dialog box, then clickthe item.
SDH: This button indicates that the transmission standard is set toSDH.
SONET: This button indicates that the transmission standard is set toSONET.
B4008 Rev. M 267
Configuration with NEW-Configurator
5.3 ADM STM-1 Extension Board (X-Connect)5.3.1 X-Connect Frame Structure Configuration
The operator may configure the frame structure on the three ports. For moreinfo, please refer to Chapter 5.2.2 (this Section)
The Frame Structure Configuration property page is available from theTransmission Configuration property sheet. Select “Enable X-Connect”from the “Termination Enabling” combo box in the “Termination and SETS”property page. The Transmission Configuration property sheet can beopened from the Configuration context menu of the transmission node in theExplorer view. The sheet can also be invoked by selecting (highlighting) thetransmission node in the Explorer view and then selecting Edit Transmis-sion Configuration from the Configuration menu .
Figure VII-82 Frame Structure Configuration Sheet
Buttons:VC-3: Sets the current structure to VC-3.VC-12: Sets the current structure to VC-12.
268 B4008 Rev. M
CityLink
Figure VII-83 X-Connect Frame Structure Configuration Sheet
5.3.2 X-Connect ConfigurationThe X-connect functionality allows the operator to connect two VirtualContainers (VC) in different ports. The connections are identified by usingthe background colour of the ports together with the KLM address of thevirtual container. The background colour of a VC identifies the source port,while the KLM address identifies the source address.
As an example consider the marked VCs in the figure below. The VC on theLine Port is X-connected with the virtual container having a KLM addressof 1,2,1 on the Radio Port. While the VC on the Radio Port is X-connectedwith the VC having a KLM address of 1,1,1 on the Line Port.
SNCP functionality is available on the Line Port and is identified with a splitcell.
Looping is achieved by connecting VCs on the same port (Traffic Looping).
The X-Connect Configuration sheet can be opened from the Configurationcontext menu of the X-Connect Extension Board node in the Explorer view.The sheet can also be invoked by selecting (highlighting) the X-ConnectExtension Board node in the Explorer view and then selecting Edit X-Connect from the Configuration menu .
B4008 Rev. M 269
Configuration with NEW-Configurator
Buttons:SNCP: Press this button to establish an SNCP connection. The SNCP
functionality will apply to the same virtual container on allports. SNCP is available on the Line Port.
Source: To establish a connection, select a virtual container from oneof the ports. Press this button to set the selected container asthe source.
Destination: Select a virtual container from one of the ports and press thisbutton to set the selected container as the destination.
Disconnect: Select a virtual container which already has an establishedconnection. Press this button to remove the connection.
Cancel: Press this button to undo the current operation.
270 B4008 Rev. M
CityLink
Figure VII-84 Hot Standby Explorer view
6.0 Hot Standby6.1 General
A CityLink Hot Standby system consists of two InDoor Units connected toan IDU Switch and two OutDoor Units connected to the a HSB branchingunit. The IDU switch performs switching in the Rx direction, while thebranching unit has an RF-switch in the Tx direction.
6.1.1 FunctionalityThe IDU switch will perform most of the normal tasks of an IDU, with the twoIDUs maintaining modem functionality. Thus, configuration of line inputs,wayside channels etc will be handled on the switch, while modem-specificfunctionality (e.g Viterbi error pulses) is found on the IDU. Some function-ality, like auxiliary outputs, are found in both places.
B4008 Rev. M 271
Configuration with NEW-Configurator
6.1.2 Element IDThe CityLink Element ID property sheet shows some main information aboutthe Network Element like name, type, serial number and different addresses.The enabled fields can be altered by users with proper user privileges.
The Element ID configuration sheet can be opened from the Configurationcontext menu of the Element node in the Explorer view. The sheet can alsobe invoked by selecting (highlighting) the Element node in the Explorer viewand then selecting Edit Element ID from the Configuration menu.
Figure VII-85 Element ID Configuration Sheet
272 B4008 Rev. M
CityLink
Fields: Description:Serial number: The serial number of the NE. (Not editable)NE type: The type of NE. (Not editable)Name: The name of the NE (max. 32 characters)Section address: The section address of the NE. (1-254)NE address: The NE address (1-128). Used for identification of
NEs within a section.MAC address: The Media Access Control address of the NE.
Used for OSI-Management. (Not editable)NSAP address: The Network Service Access Point address of the NE.
Used for OSI-Management.IP address The Internet Protocol address of the NE.1+1 Hot Standby: Select this option in order to set up a hot standby
element. A list of choices are displayed in the droplist;Standard, SD Combiner (Space Diversity Combiner),SD Hybrid (Space Diversity Hybrid) andDual Antenna.
1+1 Freq. Diversity: Select this option in order to set up a frequencydiversity element. A list of choices are displayed in thedroplist; Standard, SD Combiner (Space DiversityCombiner) and SD Hybrid (Space Diversity Hybrid)
To change the settings:1 First, get the current settings from the NE by pressing Get.
(The settings are automatically retrieved from the NE when theproperty-sheet is opened.)
2 Alter the settings you want to change.3 Press Set to send the changes to the NE.
B4008 Rev. M 273
Configuration with NEW-Configurator
Figure VII-86 HSB Looping Configuration Sheet
6.1.2.1 HSB Main LoopingThe Looping configuration sheet can be opened from the Configurationcontext menu of the Equipment node in the Explorer view. Press the Main tabto view/change the Main looping settings. The sheet can also be invokedby selecting (highlighting) the Equipment node in the Explorer view and thenselecting Edit Looping from the Configuration menu.
6.1.2 Looping ConfigurationWhen opening the Looping Sheet on a HSB NE, the pages for main, waysideand 64Kbit looping will apply for both IDUs. If a loop is set on the IDU andthe system switches, the signal will still be looped.
274 B4008 Rev. M
CityLink
Fields:Loop buttons: One button for each loop where the arrow indicates
which way the signal is looped. The colour of the looparrows describes the status of the loop:Blue: The status of the loop is unknown. Loop informa-tion has not been retrieved from the NE, or a loop messagehas just been sent to the NE and the GUI is waiting for aresponse from the NE. (The loop settings have not beenconfirmed by the NE). Note that the loop cannot be toggledwhen the status is unknown.Black: The loop is off (inactive)Red: The loop is on (active)
Loops will be Displays the time of which all main traffic loops in the NEautomatically will be cleared. This time is set by the user when activatingcleared after: a loop.
The different main traffic loops(from left to right in the respective blocks in Figure 70):• 4S. SORP LT output to LR input loop, far-end (IDU Switch)• 1S. SORP LR output to LT input loop, near-end (IDU Switch)• 12S. SORP RT output to RR input loop, near-end (IDU Switch)• 14A. IF loop, near-end (IDU A)• 15A. IF loop, near-end (ODU A)• 16A. RF loop, near-end (ODU A)• 14B. IF loop, near-end (IDU B)• 15B. IF loop, near-end (ODU B)• 16B. RF loop, near-end (ODU B)
Buttons:Close: Closes the property sheet.Help: Press this button to get help on the current property sheet page. For
help on an item, click at the top of the dialog box, then click the item.
6.1.2.2 HSB 64Kbit/s LoopingPlease refer to Chapter 4.4.2 (this Section).
6.1.2.3 HSB Wayside LoopingPlease refer to Chapter 4.4.3 (this Section).
!
"#$%%%&%
"'! ( )*#$ ) !"
!
! (! )+*#$ ) !"
,(*-+ "' .( !" #
/) &* &
B4008 Rev. M 277
Configuration with NEW-Configurator
Automatic Switch ModeThe IDU switch checks the state of both channel A and channel B regularly.This task decides whether an Rx switch is needed or not. Similarly, the Txswitching is controlled by the ODU. For the Tx switching to work, theconnected IDU signals the ODU when at least one of the switching criteriaare present on the IDU.
In automatic switch mode the following rule constrain switching:A channel switch is performed if, and only if, the channel switched to, hasno switch conditions true.
On IDU A and IDU B, a dedicated task is continuously checking whether theRx or Tx switch criteria status has changed, and if so, notifies the IDU switchand ODU about the change.
Currently, bi-directional switching is not implemented in automatic mode.
Switching algorithmThe following algorithm is applied in automatic switching mode:Compute the total severity factor of each branch (SA, SB) using the followingformula:
SCenabled1is 1 if the switching criteria “RF Input Alarm” is enabled (checked),else it is 0. SCactive1 is 1 if the alarm/category “RF Input alarm” is active(present) on the element, else it is 0.If SA = SB, switch to the preferred branch (The preferred branch is set in theHot Standby Config page)If SA > SB, switch to SB if branch A is active.If SB > SA, switch to SA if branch B is active.
Manual Switch ModeIn manual switch mode, bi-directional switching is performed only as a resultof a Q1 message from external management software (e.g. NEW-NMS).
Currently, unidirectional switching is not implemented in manual mode.
278 B4008 Rev. M
CityLink
6.1.4 Reconfiguring a Hot Standby IDU foruse in 1+0 ConfigurationAn IDU that has been used in a HSB configuration will continue to beconfigured as a HSB element until explicitly reconfigured. To do this, firstdisconnect the IDU from the switch. Then use NEW-NMS to connect tothe element with a serial cable. NEW-NMS’ explorer view should nowdisplay an equipment tree with a single node. Bring up the Element IDdialog from the Configuration menu, and disable the Hot Standby check-box. When the element is next power cycled, it will start up in 1+0 configu-ration. This can be verified with the Element ID dialog.
6.1.5 Reconfiguring a 1+0 IDU foruse in Hot StandBy ConfigurationIf the IDU used in a 1+0 is to be prepared for an IDU in a HSB system, it isvery important to do the following procedure :
1.Connect the HSB cable between the IDUs and the switch2.Power up the HSB IDU3.Power up the IDU A and IDU B
The IDUs will now be automatically reconfigured as IDUs used in a HSBsystem.
WARNING!If the Y-cable connectors marked with IDU A and IDU B areswapped, the IDUs must always be rebooted after this opera-tion.
B4008 Rev. M 279
Fast Ethernet Configuration
CityLink Fast EthernetConfiguration
SECTION VIII
280 B4008 Rev. M
CityLink
Login as admin with the password; adminpasswd
Hyperterminal & Telnet
1.0 Hyperterminal & Telnet Commands• First time configuration with hyper-terminal to IDU's LCT-
port.– Settings on com port; 9600, 8, 1, none.– Terminal emulation; VT100.
• Normal operation via IP.– Telnet session to IP-address on management port or one of the four
ethernet port’s.
Figure VIII-1 Starting up and logging in
Note!NEW-NMS' security system has initially one user account:
User ID: adminPassword: adminpasswd
It is strongly recommended to change this password!
B4008 Rev. M 281
Fast Ethernet Configuration
2.1 How to get this link alive, parameters• Enable IP as described in Chapter 4.8.1 (this Section). Enable IP on
one of the four traffic port’s and do settings from NEW-NMS.– Frequency on both elements must match (Tx to Rx).– Maximum output power.– Tune antennas for maximum Rx-levels.
• Verify that transmission is OK over the hop.– Enable and test on a 2Mb/s or connect with computers on the LAN.
LA N 1
LAN 2
LAN 3
LA N 4
City
Link
IDUF as t
E the rne tT ribu ta ryM odu le
2 (1 .5 ) M b /s c ircu it 1 - 4
LA N 1
LA N 2
LA N 3
LA N 4
City
Link
IDU F ast
E the rne tT ribu ta ryM odu le
2 (1 .5 ) M b /s c ircu it 1 - 4
EthernetExtension
Board(EEB)
EthernetExtension
Board(EEB)
2.2 Testing• How to verify transmission quality and capacity ?
– One way to do this is to set up two computers and do a file transfer(FTP) between them over the hop.
One PC working as FTP-server and one as FTP-client, check thetime for transfer of the file and calculate throughput.
Do not have any HUBs connected during this test.
– Stability of the equipment and hop will be easiest monitored onBER test with pattern-generator on a 2Mb/s.
2.0 How to get this link aliveWhere to start– Status?– Do we want a IP connection to the IDU? If you have NEW-NMS, then
the answer is yes.Enable IP one of the four traffic port’s and do all settings fromNEW-NMS.
Figure VIII-2 Radio Connection
282 B4008 Rev. M
CityLink
3.0 Top Level CommandsAfter logon you should have this text on your screen;
Welcome to CityLink.Copyright (c) Nera ASA.CityLink>
Then type help and press enter:
Welcome to CityLink.Copyright (c) Nera ASA.CityLink> helpHelp:
The following commands are available:
Command Functionalarms lists alarmscls clear screencoldstart shutdown the system and make a cold start of the systementer enter submenuenv list environment variablesexit exit submenugettime display system timezone, time and datehelp get help on commandslist list available commandsping ping the specified hostquit quit shellreboot shutdown the system and rebootsettime set system timezone, time and datetracert trace route to target
Use "help <command>" to get help on specific command.
Example for usage of "Help":
CityLink> help gettimegettime: display system timezone, time and dateUsage: gettime
CityLink>
B4008 Rev. M 283
Fast Ethernet Configuration
3.1 Top Level Commands, ExampleCityLink (radio)> alarmsActive alarms: TIME ID NAME CLASS STATE
Modem. 2001.11.19 11.04.50 1104 E-WARNING WARNING Raised 2001.11.19 11.04.50 1103 LBER MINOR Raised 2001.11.19 11.04.50 1102 HBER MAJOR Raised
Baseband 2001.11.19.11.04.50 32808 LOS_RR MAJOR Raised 2001.11.19.11.04.50 32809 LOF_RR MAJOR Raised 2001.11.19.11.04.50 32811 MS-AIS_INSERT_RR MAJOR Raised
EEB 2001.11.19.11.04.50 32785 ETHERNET_PORT_2 INFO Raised 2001.11.19.11.04.50 32786 ETHERNET_PORT_3 INFO Raised 2001.11.19.11.04.50 32787 ETHERNET_PORT_4 INFO Raised
PerfManager 2001.11.19.11.15.01 3000 G826-15MIN-B1 WARNING Raised 2001.11.20.00.00.01 3003 G826-24HOUR-B1 WARNING Raised
CLIServer 2001.11.20.14.35.20 32782 CONSOLE_USER_LOGGED_IN INFO Raised
284 B4008 Rev. M
CityLink
4.0 Submenu CommandsThe command structure is top level commands and submenu commands.Top level commands are also available at submenu levels.The following submenus are available by typing enter and then submenu:
4.1 EEB SubmenuConfiguration of Ethernet module– Enable LAN ports– Select the important LAN port– Enable 2Mbit/s ports
Submenu commands:Submenu Function Security
Leveleeb monitor and control of EEB passivebaseband perform baseband module commands passivemodem perform modem module commands passiveradio monitor and control of ODU passivesu monitor and control of SU passivesecurity perform security administration passiveperform monitor and control of Performance data passiveconfig Lists and modifies configuration settings passivetest perform test function commands passivefault Query and manipulate alarms and alarm settings activeq1module Lists and modifies q1 and nnp protocol settings master
EEB submenu commands:Command Functionautopartition enable / disable autopartitioneebstatus show GT-48350 link/partition statusget2mbport get 2MBit E1/T1 port state (from SW Version R1C0
this command has been replaced by gettribport)getethmode get Ethernet ports speed and duplex modegettribmode get tributary E1/T1 ports modegettribport get tributary E1/T1 port stategetethport get Ethernet port stategetflowctrl get flow control for Ethernet portlistportmib list the MIB-statistics of a portselectpriport select priority Ethernet portset2mbport set 2MBit E1/T1 port state (from SW Version R1C0
this command has been replaced by settribport)
B4008 Rev. M 285
Fast Ethernet Configuration
4.2 Baseband SubmenuConfiguration of IDU– Enable 2Mbit/s Wayside– Enable 64kbit/s channels
Baseband submenu commands:Command Functionget64kg703 get g703 enable/disableget64kv11 get v11 enable/disablegetlaser get current laser stategetwayside get wayside enable/disableresetbaseband reset eeb moduleset64kg703 set g703 enable/disableset64kv11 set v11 enable/disablesetlaser sets the laser statesetwayside set wayside enable/disablestartlaser starts the laser
If Flow control is set this will cause a feedback to the “sender” if the porthave to much to do. In this case you will avoid lost or dumped packages andyou may see an improvement of the throughput if “sender” support flowcontrol!
setethmode set Ethernet port speed and duplex modesettribmode set tributary E1/T1 ports modesettribport set tributary E1/T1 port statesetethport set Ethernet port state
286 B4008 Rev. M
CityLink
4.3 Modem Submenu (part of IDU)validberlevels– BER = Bit Error Ratio, Number of errored bit’s divided on total number
of bits.High BER = 1x10-3
Low BER = 1x10-6
Early Warning (BER) = 1x10-9
Settings of FIR and SERF index are set from factory! Do not change them!Contact Nera to get FIR and SERF index if necessary.
Modem submenu commandsCommand Functiongetberlevels get HBER, LBER and ER levelsgetfirindex get current fir tap indexgetserfindex get current serf set indexresetmodem reset modemsetberlevels set HBER, LBER and EW levelssetfirindex set current fir tap indexsetserfindex set current serf set indextempcomp get temperature compensation datavalidberlevels show valid HBER, LBER and ER levels
Remember to use NEW-NMS or NEW-Configurator when changingfrequency plan used on the system, because then these setting will becorrect.
B4008 Rev. M 287
Fast Ethernet Configuration
4.4 Radio Submenu (part of ODU)Configuration of ODU– Set frequency, normally done during installation. However, this will be
necessary to set for spare parts.
Radio submenu commands:Command Function Usage Security
Leveldownloadodusw transfer ODU SW No parameters master
from IDU to ODUdrotuning get/set ODU DRO drotuning [disable | tx | rx] master
tuning mode/statusgetatpc get Automatic- No parameters passive
PowerControl settingsgetfrequency get tx and No parameters passive
rx frequencygetmutestate get radio mute state No parameters passivegetrfpower get rf output No parameters passive
and input powergetrfwarning get RfInputLevel- No parameters passive
Warning up anddown
radiostatus display all No parameters passiveradio settings
reloadfreq transfer current No parameters masterfrequency settingsto ODU
setatpc set Automatic- setatpc <state | rxref | almoutlevel | almdelay> masterPowerControl state: state <enable | disable>functions rxref: rxref <level in dBm>
almoutlevel: almoutlevel <level in dBm> almdelay: almdelay <delay in seconds>
setfrequency set tx and setfrequency <txfreq> <rxfreq> masterrx frequency
setmutestate set radio mute state setmutestate < on | off> mastersetrfpower set rf output power setrfpower <‘OutputPower in dBm’> mastersetrfwarning set RfInputLevel- inputwarning <WarningLevelUp> master
Warning up and <WarningLevelDown>down
288 B4008 Rev. M
CityLink
4.4.2 Radio Commands, Example of Error MessageCityLink (radio)> setfrequency 22190000 23198000
Frequency out of range!
TxFrequency: 23198000 kHzRxFrequency: 22190000 kHzTxFreq.Min : 23086000 kHzTxFreq.Max : 23534000 kHzRxFreq.Min : 22078000 kHzRxFreq.Max : 22526000 kHzDuplexDistance: 1008000 kHz
CityLink (radio)> setfrequency 23198000 22190000
4.4.1 Radio Status, ExampleCityLink (radio)> radiostatusRadio Configuration
ODU:RF input = -113.00 dBmODU:RF output = 14.00 dBmODU:+48V = 48.00 VRadio Muted = 0Loop status = 0Loop capability = 3Transceiver S/N = 96Radio Type = 1Transceiver Type = 10Boot Code Version = 1A0App. Code Version = 4D2App. Code Date = 2001-12-04 17:04:55
Radio Alarms.Alarm : 1502 LOS_RF_INPUTAlarm : 1504 RF_INPUT_WARNING
Tx Frequency = 23198000 kHzRx Frequency = 22190000 kHzLast FrqShift = OkTx Frequency Min = 23086000 kHzTx Frequency Max = 23534000 kHzRx Frequency Min = 22078000 kHzRx Frequency Max = 22526000 kHzDuplex Distance = 1008000 kHzRf Output Power = 15 dBmRf Output Power Max = 18 dBmRf Output Power Min = 8 dBmRf Input Warning Low = -60 dBmRf Input Warning Up = -35 dBmATPC state = 0ATPC Rx Ref Level = -10 dBmATPC alm Out Level = 15 dBmATPC alarm Delay = 12 sec.
B4008 Rev. M 289
Fast Ethernet Configuration
4.5 SU Submenu (part of IDU)Important issues for maintenance and troubleshooting could be to inves-tigate RF-input level and DC-level in ODU.
SU submenu commands:Command Functiongetanaloge list analogue sensor measurementsgetauxinput list aux port inputs signals and configuartiongetauxoutput list aux port outputs signals and configurationgetfan get fan statussetauxinput configure aux port inputs signalssetauxoutput configure aux port outputs signals
4.6 Security SubmenuIt is important to limit the valid range of IP-addresses to reduce possibilityof “hacking”. It is also recommended to customize the SNMP password(community strings), also in NEW-NMS.
Security submenu commands:Command Functionadduser make a new user accountchangename change «current user» description namechangepwd change «current user» passwordchangesnmppwd change SNMP password (community string)deleteuser delete user accountgetiprange list secure IP rangesgetlog list security loggetsnmppwd list SNMP password (community strings)getuser list usersresetlog resetlog deletes all entries in security logresetsecurity reset security to factory settingssetiprange set secure IP rangesetusername set User description namesetuserpwd set User passwordwho list users logged on
290 B4008 Rev. M
CityLink
4.7 Performance SubmenuThe Performance submenu shows the quality on your received signal fromopposite Citylink.
Perform submenu commands:Command Functiongetfec list FEC countergetg826 list G.826 performance valuesgetpulses list error pulsesgetthreshold list G.826 Thresholdsperformstatus list all performance parameters availableresetfec reset FEC counterresetg826 reset G.826 performance valuesresetpulses reset error pulsessetthreshold set G.826 Thresholds
4.8 Configuration SubmenuConfiguration of the CL Element– Set system type.– Set section and station address, name etc...– Important to execute command "setinterface" in order to enable
management via IP.
Config submenu commands:Command Functionaddroute Adds routes to the routing tableauthenticate Authenticates access keys to enable licensed functionallitydeleteroute Deletes routes from the routing tableeebni Sets or gets state on EEB network interfacegetsysmode Gets the system operation modeinventory Prints inventory datalistnetconfig Lists the network configurationlistroute Lists the routing tablelistsysconfig Lists current system configurationsetantennatype Sets the antennatypesetgateway Sets the default gatewaysetinterface Sets the IP address and netmask of an interfacesetsectionaddr Sets the section addresssetstationaddr Sets the station addresssetstationname Sets the station namesetsysconfig Sets system configurationsetsysmode Sets the system operation mode
B4008 Rev. M 291
Fast Ethernet Configuration
4.9 Test & Fault SubmenuTest submenu commands:Command Functiongetloop get current looping statesetloop toggle looping state on/off
Fault submenu commands:Command Functionalarmlog lists alarmlog entriesclearalarm clears an alarmmaskalarm masks an alarmraisealarm raises an alarmunmaskalarm unmasks an alarm
4.8.1 Management SettingsCityLink (config)> setinterface helpUsage: setinterface <if#> < [<ipaddress> <netrmask>] | [<disable>]>
if# : Interface no (1-5)ipaddress : IP Addressnetmask : Subnet Maskdisable : Disable Interface if#
CityLink (config)> setinterface 02 192.168.1.1 255.255.248.0
CityLink (config)> setgateway 192.168.7.15
CityLink (config)> listnetconfig
Network interfaces.# Address Netmask Description01 192.168.0.32.1 255.255.255.255 Management port02 192.168.1.1 255.255.248.0 EEB interface 103 Disabled EEB interface 204 Disabled EEB interface 305 Disabled EEB interface 4
Default gateway : 192.168.7.15
snmpagent Enables or disables the SNMP agentstationinfo Lists Station/Section infoupdatesw Updates the system software
292 B4008 Rev. M
CityLink
4.10 Q1module SubmenuQ1module submenu commands:Command Functionlistinterface List the nnp interfaceslistroutes Lists the nnp routing tablesetaddress Set the Q1 address of the element
B4008 Rev. M 293
Fast Ethernet Configuration
5.0 Software Upgrade Procedure forthe CityLink Fast Ethernet Device
1. Download software file to IDU via ftp (1). Note: the filename must bein 8.3 (xxxxxxxx.eee) format. See Chapter 5.1 (this Section)
2. Log in on console or telnet session to the IDU and in the “config”submenu issue the command “updatesw [filename]”, where [filename]is substituted for the name given to the file in step 1.
3. After the file is loaded to flash, reboot the IDU.
Figure VIII-3
294 B4008 Rev. M
CityLink
5.1 How to download a file to the IDU:[host] : is either the host name for your IDU or the IP address inxxx.xxx.xxx.xxx format.
5.1.1 Using the Console FTP ClientIn a dos prompt go to the folder where your file is stored. Issue thecommand “ftp [host]” and log in with your administrator password. On theftp client prompt issue the following commands:
“bin” to enable binary transfers.“hash” to toggle printing `#' for each buffer transferred“put [filename]” to transfer the file.“bye” or “quit” to exit the ftp client.
Figure VIII-4 Downloading using the Console FTP Client
B4008 Rev. M 295
Fast Ethernet Configuration
5.1.2 Using the Internet Explorer(This requires downloading the browsing enhancements from Microsoft)Go to the URL “ftp://[host]” and log in with your administrator password.Drag the software file from a local folder to the Internet explorer window.Close Internet explorer to terminate the connection
Figure VIII-5 Downloading using the Internet Explorer
296 B4008 Rev. M
CityLink
5.2 How to download a file to the ODU1. Download ODU software file to IDU via ftp. Ref. 5.1 above.2. Log in on console or telnet session to the IDU and in the “radio” submenu
issue the command “downloadodusw”.3. After the file is downloaded to ODU, ODU is automatically rebooted.
Figure VIII-6
B4008 Rev. M 297
Fast Ethernet Configuration
NEW Network Management SystemThe management and supervision of CityLink Fast Ethernet may beperformed in various ways depending on the actual application.• NERA’s NEW-NMS can work as an SNMP-manager and control and
supervise the radio-relay (described in the follwing chapters).• The CityLink Fast Ethernet may be treated as just another LAN device
and controlled and supervised via the built in SNMP agent (describeddirectly after the NEW-chapters).
• Interfaces: 10Base-T LAN port or one of the 4 Ethernet ports.
6.0 Start NEW-NMS & ConnectFirst set master as community name.The SNMP Settings configurationsheet can be opened from the Configuration menu. Use same commu-nity name as in Chapter 4.6 (this Section) Security Submenu.
Figure VIII-7 Setting Community Name in SNMP Settings
Add IP with SNMP checked or specify Search area and do a discover. Fordetails regarding adding elements and discover; see the NEW-NMSmanual (B1091).
298 B4008 Rev. M
CityLink
Fields: Description:Get: The community string used during discovery of SNMP
elements NOT defined in any search area.Set: Default Set community string for elements NOT defined
in any search area.SNMP: The UDP port used as destination port for discovery of
SNMP elements.Trap: UDP port used by NEW-NMS for receiving Traps.Start Address: Starting IP address of the range to be searched. Format of
the address must be xxx.xxx.xxx.xxx.Stop Address: Stop IP address of the range to be searched. Stop address
must be equal or greater than start address. Format of theaddress must be xxx.xxx.xxx.xxx.
Add an entry to the search area:1.Press the Add button, an entry is added to the list. By default start address
= «0.0.0.0», stop address = «0.0.0.0», read community = «public», andwrite community = «private».
2.To change the default values dobbel click the entry in question and enterthe wanted value.
3.To save your settings press OK.
Remove an entry from the search area:1.Select the entry from the list.2.Press the Remove button.3.To save your settings press OK.
B4008 Rev. M 299
Fast Ethernet Configuration
Figure VIII-8 Adding IP Address
300 B4008 Rev. M
CityLink
7.0 Network Element ConfigurationConfiguration of Network Elements is achieved using a set of property-sheets. The property-sheets are modeless, so configuration of severaldifferent modules can be displayed simultaneously.
••••• To open the configuration property sheets:Select the object you want to view or change either from the Explorer Viewor a Map View. Select a Configuration command either from the contextsensitive menu (right mouse-button) or from the Configuration Editmenu.
The property-sheets are divided into two categories by means of function-ality:
Figure VIII-9 Buttons on Configuration property sheets withmultiple settings
Configuration Property sheets with Multiple Settings:The program retrieves the current settings from the Network Element(NE) when the property-sheet is opened. No set-messages is sent to theelement and no data is modified in program’s data structure before the userpresses one of the property-sheet buttons:
Buttons:Set: Applies the current settings in the Network Element (NE).Get: Retrieves the current settings of the Network Element (NE).Close: Closes the property-sheet without saving or setting any data.Help: Displays help for the active property-page.
To change the settings:1 First, get the current settings from the NE by pressing Get. (The
settings are automatically retrieved from the NE when the property-sheet is opened).
2 Alter the settings you want to change.3 Press Set to send the changes to the NE.
B4008 Rev. M 301
Fast Ethernet Configuration
Configuration Property sheets with Single Interactive Settings:The program retrieves the current NE settings when the property-sheet isopened. Has no Get or Set buttons; All functional buttons are placed in theproperty-pages. A message is sent to the Network Element immediatelywhen a control is changed or a button is pressed.
Property-sheet buttons:
Figure VIII-11 Configuration property sheet information field
Figure VIII-10 Buttons on Configuration property sheets withsingle active settings
Buttons:Close: Closes the property-sheet.Help: Displays help for the active property-page.
All property-pages have an information field at the bottom reflecting thecurrent status of the data shown in the property-page and the date and timethe property sheet data was retrieved from the Network Element.
302 B4008 Rev. M
CityLink
8.0 Element Node8.1 Element Id
The CityLink Element Id property sheet shows main information about theNetwork Element like name, type, serial number and different addresses.The fields with white background can be altered by users with proper userprivileges The gray fields are non-editable.
The Element Id configuration sheet can be opened from the Configura-tion context menu of the Element node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit Element ID from the Configu-ration menu.
Figure VIII-12 Element ID Configuration Sheet
Fields: DescriptionSerial Number: The serial number of the NE. (Not editable)NE Type: The type of NE. (Not editable)Name: The name of the NE. (max. 32 characters)Section Address: The section address of the NE.NE Address: The NE address. Used to identify NEs within a
section.MAC Address: The Media Access Control address of the NE. (Not
editable)IP Address: The Internet Protocol address of the NE.
B4008 Rev. M 303
Fast Ethernet Configuration
8.2 NE ClockThe NE Clock sheet lets you synchronize the Network Element Date/Timewith the NEW-NMS/PC Date/Time. (The NE Clock is set to the same date/time as the PC Clock)
The NE Clock configuration sheet can be opened from the Configurationcontext menu of the Element node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit NE Clock from the Configura-tion menu.
Figure VIII-13 NE Clock Configuration Sheet
Fields: Description:The Element’s Clock: The Date and Time retrieved from the NE.Difference from The difference between the PC clock and theNEW-NMS (your PC): NE Clock
304 B4008 Rev. M
CityLink
8.3 Software VersionsThe software versions property sheet displays the software revisions andstatus of the SU and the available subunits
The SW Versions configuration sheet can be opened from the Configu-ration context menu of the Element node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit SW Versions from the Config-uration menu.
Fields: Description:SW Component: Software titleBank: Software locationRevision: Sofware revision. The field will display “unknown”
if the system has this unit present, but is unable toretrieve the information from it.
Status: Valid: Complete or valid software.
Figure VIII-14 SW Versions Configuration Sheet
B4008 Rev. M 305
Fast Ethernet Configuration
8.4 Production DataThe production data property sheet presents details about the HW compo-nents within CityLink Fast Ethernet.The Production Data configuration sheet can be opened from the Con-figuration context menu of the Element node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the Element node inthe Explorer view and then selecting Edit Production Data from theConfiguration menu.
Fields: Description:
InventoryName: The name of the HW component.InventorySerialNumber: The serial number of the HW component.InventoryVersion: The HW component version.
Figure VIII-15 Production Data Property Sheet
306 B4008 Rev. M
CityLink
8.5 SNMP Agent(s) SettingsThe SNMP Agent(s) property sheet shows the current SNMP settings. TheElement SNMP Settings configuration sheet can be opened from theConfiguration context menu of the Element node in the Explorer view.The sheet can also be invoked by selecting (highlighting) the Elementnode in the Explorer view and then selecting Edit SNMP Settings fromthe Configuration menu. All information presented in the configurationsheet is set locally and not retrieved from the element.
NOTE! In order for NEW-NMS to manage the SNMP element, the SNMPAgent settings configured locally must match the settings in the NEW-NMS. Please see the CityLink Fast Ethernet Agent Configuration.
NEW-NMS is using received traps for keeping an accurate element status.SNMP Traps are unreliable and no delivery guarantee is given, to over-come this weakness a query for number of traps sent from the SNMPelement must be performed from NEW-NMS at given time intervals. If thenumber of traps sent from the element is not equal to the number of trapsreceived from the element, traps have been lost and alarm synchronizationis needed.
Figure VIII-16 Element SNMP Settings Property Sheet
B4008 Rev. M 307
Fast Ethernet Configuration
Columns: Description:IP address The Internet Protocol address of the
NE (not editable).Set Community: The community string used when
setting information at the element(set request).
Get Community: The community string used whenretrieving information at the element(get/getNext request).
Port: Element UDP Port forGet/Getnext/Set
No. Receivers: Number of Managers set up to receivetraps from this element.(Not used)
••••• Edit values in the list:The values of the columns SetCommunity, GetCommunity, Port, andNo Trap receiving Managers can be modified:
1. Double click cell to be edited.2. Type new value.3. Click outside cell.4. To save your settings press Set.
308 B4008 Rev. M
CityLink
8.6 Trap TableThe trap table presents information about the managers currently regis-tered to receive traps.The Trap Table configuration sheet can be opened from the Configura-tion context menu of the Element node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit Trap Table from the Configu-ration menu.
Fields: Description:IP Address: IP address of the registered SNMP managertrap Port: Which port is used for sending Traps to managersLast access: Time the agent was last accessed by the SNMP manager
Figure VIII-17 Trap Table Configuration Sheet
B4008 Rev. M 309
Fast Ethernet Configuration
8.7 MIB II - System GroupThe System Info property page shows some of the MIB-II System Groupattributes. The fields with white background can be altered by users withproper user privileges. The gray fields are non-editable.
The MIB II Info configuration sheet can be opened from the Configurationcontext menu of the Element node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit MIB II Information from theConfiguration menu.
Figure VIII-18 System Info Property Sheet
310 B4008 Rev. M
CityLink
Fields: Description:Sys Description: A textual description of the entity. This value should
include the full name and version identification of thesystem’s hardware type, software operating-system,and networking software. It is mandatory that this onlycontain printable ASCII characters.
Sys OID: The vendor’s authoritative identification of thenetwork management subsystem contained in theentity. This value is allocated within the SMI.enterprises subtree (1.3.6.1.4.1) and provides an easyand unambiguous means for determining ‘what kind ofbox’ is being managed.
Name: The name of the Network Element.Location: The physical location of this node (e.g., ‘telephone
closet, 3rd floor’).Contact: The textual identification of the contact person for
this managed node, together with information on howto contact this person.
Sys Uptime: The time since the network management portion of thesystem was last re-initialized.
••••• To change the settings:In order for the user to change settings the Set Community name must beconfigured as described in SNMP Agent(s) settings.1 First, get the current settings from the NE by pressing Get. (The
settings are automatically retrieved from the NE when the property-sheet is opened).
2 Alter the settings you want to change.3 Press Set to send the changes to the NE.
B4008 Rev. M 311
Fast Ethernet Configuration
8.8 MIB-II SNMP GroupThe MIB-II SNMP property page presents the performance of the under-laying SNMP implementation on the managed entity and tracks things suchas the number of SNMP packets sent and received.A complete description of each field is available by holding the mousecursor over wanted item in the dialog and the description found in RFC-1213 will be displayed.
Figure VIII-19 MIB-II SNMP Property Sheet
Fields: Description:
OID Object IDentifier, uniquely defines a managed objects. Thesecan appear in two forms: numeric (i.e. 1.3.6. 1.2.1.11.1) and«human readable» (i.e. iso.org.dod.internet.mgmt.mib-2.snmp.snmpInPkts)NEW-NMS uses «human readable» form and will display theabove example as snmpInPkts.
Value Value contained in this OID.
312 B4008 Rev. M
CityLink
8.9 LoopingThe Looping configuration sheet can be opened from the Configurationcontext menu of the Element node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the Element node in theExplorer view and then selecting Edit looping from the configurationmenu.
The loop settings are divided into three categories: Main Traffic Loops,2Mbit/s Wayside traffic looping, and 64kbit/s looping.
Loops can be toggled on/off by pressing the loop-buttons placed on top ofa schematic bitmap. Only one loop can be active at any given time.The Loop Expire time has to be set to a time later than the current time.This time must not be more than 30 days from the current time. The loopwill stay active until the Loop Expire Time is exceeded even if thelooping page is closed.
When a loop button is pressed, but no response from the NE is received,the loop button is colored blue. When a loop is confirmed on, it is coloredred.
B4008 Rev. M 313
Fast Ethernet Configuration
8.9.1 Main Traffic Loops8.9.1.1 Radio Terminal
The different main traffic loops:All main traffic near end loops are swapped (port 1 → port 2, port 3 → port4).
Baseband Loop (far end) - Outgoing line traffic to incoming line traffic.Baseband Loop (near end) - Incoming line traffic to outgoing line traffic.IF Loop IDUIF Loop TransceiverRF Loop TransceiverEthernet Loop near end with swapE1/T1 loops near endE1/T1 loops far end
Figure VIII-20 Looping Configuration Sheet, Radio Terminal
Note! FAR end loop will break management traffic to other side.
314 B4008 Rev. M
CityLink
8.9.1.2 Line Terminal
The different main traffic loops:All main traffic near end loops are swapped (port 1 → port 2, port 3 → port4).
Ethernet Loop near end with swapE1/T1 loops near endE1/T1 loops far endLine TX SORP LR out to LT in loop endLine RX SORP LT out to LR in loop near end
Figure VIII-21 Looping Configuration Sheet, Line Terminal
Note! FAR end loop will break management traffic to other side.
B4008 Rev. M 315
Fast Ethernet Configuration
8.9.2 Wayside Loops
The different 2 Mbit/s Wayside Loops:Wayside Loop (far end)Wayside Loop (near end)
Figure VIII-22 Looping Configuration Sheet, Wayside Channel Tab
316 B4008 Rev. M
CityLink
The different 64kbit/s loops:64kbit/s Channel 1 Loop (far end)64kbit/s Channel 1 Loop (near end)64kbit/s Channel 2 Loop (far end)64kbit/s Channel 2 Loop (near end)
8.9.3 64 kbit/s Loops
Figure VIII-23 Looping Configuration Sheet, 64kbit/s Tab
B4008 Rev. M 317
Fast Ethernet Configuration
9.2 Ethernet Extension BoardThe main purpose of the Ethernet Extension Board (EEB) is to convertEthernet to/from STM-1 frames. The EEB also multiplexes 4 E1/T1 channelsinto the STM-1 frames.The EEB configuration sheet can be opened from the Configuration contextmenu of the IDU node in the Explorer view. The sheet can also be invokedby selecting (highlighting) the IDU node in the Explorer view and thenselecting Edit Ethernet Extension Board from the Configuration menu
9.0 In Door Unit (IDU)9.1 64 kbit/s Channels
Two 64 kbit/s channels can be inserted into the SOH. Each of the 64kbit/schannel will occupy one byte of the SOH frame. Both channels can beretrieved from and inserted into the line and radio side independently.The 64 kbit/s Channels configuration sheet can be opened from theConfiguration context menu of the IDU node in the Explorer view. The sheetcan also be invoked by selecting the IDU node in the Explorer view and thenselecting Edit 64 kbit/s Channels from the Configuration menu.
Fields: Choices: Description:
Status: Enabled Enables the 64 kbit/s ChannelDisabled Disables the 64 kbit/s Channel
Direction: Choose the direction the 64 kbit/s Rx channelshould be extracted from.
Line 64 kbit/s Rx is inserted from line SOH framesRadio 64 kbit/s Rx is inserted from radio SOH frames
Figure VIII-24 64kbit/s Channels Configuration Sheet
318 B4008 Rev. M
CityLink
9.2.1 Ethernet Ports
Figure VIII-25 Ethernet Ports Configuration Sheet
Fields: Description:portEthStatus This entry enables/disables the port.portEthFlowCtrl This entry controls flow control setting.portEthLinkStatus This entry shows the current link status.portEthPartitionStatus This entry shows the current partiton
status for the port.portEthLinkSpeed This entry controls the link speed for the
port.portEthLinkDuplex This entry controls the link duplex mode for
the port.portEthLinkFailureShutdown This entry controls the Link Failure
Shutdown mode for the port.When enabled port is forced shutdowndue to SDH alarm or remote ETH-port noLink.Note: Port is NOT forced shutdown asdescribed above if IP management isenabled on port.
B4008 Rev. M 319
Fast Ethernet Configuration
9.2.2 2 Mbit/s PortsConfiguration of tributary E1/T1 ports (2Mbit/s or 1.5Mbit/s).
Fields: Description:port2MBIndex Tributary E1/T1 port index .port2MBStatus Presents the status of the tributary E1/T1 port.
Figure VIII-26 2Mbit/s Ports Configuration Sheet
Priority Port Designates the prioritized port.(Guaranteed100Mb operation.)
Auto Partition Auto partition state for the EEB ethernetports.
Note :Ethernet Port fixed speed / duplex mode setting:1) Set user terminal equipment speed / duplex mode to Auto.2) On CityLink FastEthernet port sett required link speed.
Note: It is not recommended to use 10Mb Half duplex .
320 B4008 Rev. M
CityLink
9.3 Wayside ChannelA Wayside channel can be inserted in the SOH in either line-direction orradio-direction. The Wayside channel will occupy 33 bytes (32 bytes data+ 1 byte alignment information) of the SOH. The Wayside channel use theRx and Tx connection at the front panel of the IDU. Rx is received data andTx is sent data.The Wayside configuration sheet can be opened from the Configurationcontext menu of the IDU node in the Explorer view. The sheet can also beinvoked by selecting (highlighting) the IDU node in the Explorer view andthen selecting Edit Wayside from the Configuration menu.
Fields: Options: DescriptionStatus: Enabled Enables the Wayside Channel
Disabled Disables the Wayside ChannelDirection: Line Wayside Rx is extracted from line SOH
Radio Rx is extracted from radio SOH.
Figure VIII-27 Wayside Channel Configuration Sheet
B4008 Rev. M 321
Fast Ethernet Configuration
9.4 Auxiliary OutputThere are four configurable auxiliary output pins in the ALM/AUX port.The pins are connected to a relay, which can either be controlled manually,or triggered automatically on a user selectable alarm.The Auxiliary Output Configuration sheet can be opened from theConfiguration context menu of the IDU node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the IDU node in theExplorer view and then selecting Edit Auxiliary Output from theConfiguration menu.
Figure VIII-28 Auxiliary Output Configuration Sheet
322 B4008 Rev. M
CityLink
Controls: Choices: Description:
Output control radio Manual control Set the usage of the auxiliarybuttons: or output pin. (Disabled if the
Alarm triggered CityLink does not support alarmtriggers.)
Manual Relay status Closed or open If the auxiliary output is set toradio buttons manual control, these buttons
will be enabled, and can be usedto manually control the state ofthe relay.
Equipment tree - Displays and selects the alarmsavailable for alarm triggers. Thiswill be disabled if the auxiliaryoutput is set to manual control.
Alarm trigger list - Displays the alarm triggersconfigured. Disabled if theauxiliary output is set tomanual control.
Add alarm button - Adds the currently selectedalarm in the equipment tree tothe alarm trigger list. If there isno selection, or if the selectedtree node doesn’t correspondto an alarm, nothing happens.Disabled if the output is onmanual control.
Remove alarm button - Removes the currently select-ed alarm from the alarm triggerlist. Disabled if the output is onmanual control.
Alarm triggered relay Closed or Open If the auxiliary output is set tostatus radio buttons alarm triggered control, these
buttons will be enabled, and canbe used to control the state ofthe relay when the alarm-conditions are raised.
B4008 Rev. M 323
Fast Ethernet Configuration
9.5 BER ThresholdsThe Viterbi decoder is a component using a Viterbi low complexityalgorithm for decoding/error correcting the received bit-sequence in theNE. The viterbi error rate is used as a quality measurement for the radiohop.
When the Viterbi error rate exceeds certain values, alarms are generated.The threshold values decides when alarms are generated. The thresholdvalues can be changed by the user.
Alarm Id Default value Alarm severityHBER Indicator for BER >1exp-3 MAJORLBER Indicator for LBER >1exp-6 MINOREW-BER Indicator for EW-BER >1exp-10 WARNING
Internal proportions: HBER > LBER > EW
The BER Threshold configuration sheet can be opened from the Config-uration context menu of the Radio node under the IDU node in theExplorer view. The sheet can also be invoked by selecting (highlighting)the Radio node under the IDU node in the Explorer view and thenselecting Edit BER Threshold from the Configuration menu.
Figure VIII-29 BER Threshold Configuration Sheet
324 B4008 Rev. M
CityLink
Fields: Choices: Description:
HBER 1.0e-3 - 1.0e-10 Range.A Major alarm is generated when theViterbi error rate exceeds the High BERthreshold value. AIS is inserted when theHBER threshold value is exceeded.
LBER 1.0e-3 - 1.0e-11 Range.A Minor alarm is generated when theViterbi error rate exceeds the Low BERthreshold value.
EW 1.0e-3 - 1.0e-12 Range.A Warning is generated when theViterbi error rate exceeds the ErrorWarning threshold value.
B4008 Rev. M 325
Fast Ethernet Configuration
9.6 Laser ControlAvailable on CityLink Fast Ethernet Line Terminal only.
The optical port may or may not have implemented Automatic LaserShutdown (ALS). This is a function designed for eye safety purposes,according to ITU-T rec. G.958. When implemented, ALS may be enabledor disabled.
When ALS is not implemented or enabled the laser must be turned on/offmanually.
When ALS is enabled, the laser automatically will restart after a waitingtime period (selectable), when having previously been turned off. (If thesection of operation is not connected or Loss Of Optical Signal from farend is detected, the laser will again be turned off after 2 sec.) The waitingperiod is by default set to 1 minute.
The Laser Control configuration sheet can be opened from the Config-uration context menu of the Optical Line node under the IDU node inthe Explorer view. The sheet can also be invoked by selecting (highlight-ing) the Optical Line node under the IDU node in the Explorer view andthen selecting Edit Laser Control from the Configuration menu.
Figure VIII-30 Laser Control Configuration Sheet
326 B4008 Rev. M
CityLink
Fields: Buttons: Description:
ALS:Enabled/Disabled Toggles ALS On/OffWaiting Time (1.0 - 5.0 minutes ) Specifies waiting
time before the laser is turned on. Ifsection of operation is connected andoptical signal from far end is present,laser will remain on, if not laser willbe turned off after 2 seconds.
Get Retrieves Laser Control settingsfrom the NE.
Set Sends Laser Control settings to the NE.Restart (2 Seconds) Manually restart the laser for
2 seconds.Restart (90 Seconds) Manually restart the laser for
90 seconds for testing purposes.
ManualControl: (ALS disabled or not implemented)
On Manually turn the laser on.Off Manually turn the laser off.Status: Shows the status of the Laser Unit.
B4008 Rev. M 327
Fast Ethernet Configuration
10.0 Out Door Unit (ODU)10.1 Antenna Data
This sheet shows some main characteristics of the antenna. Only theantenna code can be altered. The antenna data are stored in a database file.The Antenna Data configuration sheet can be opened from the Configu-ration context menu of the Antenna node in the Explorer view. The sheetcan also be invoked by selecting (highlighting) the Antenna node in theExplorer view and then selecting Edit Antenna from the Configura-tion menu.
Figure VIII-31 Antenna Data Configuration Sheet
Fields: Description:Antenna code The antenna code. Unique code for each antenna type.Gain The antenna Gain. (dB) Gain is a measurement of the
antennas ability to transform electrical signals toelectromagnetic waves.
Polarization The polarization direction of the antenna.FB Front/Back Ratio. Ratio between the Gain in forward
direction and Gain in backward direction.Diameter The physical antenna diameter. [ Meter]Frequency range The frequency range where the antenna can be
expected to operate successfully.
328 B4008 Rev. M
CityLink
10.2 Power SettingsATPC (Automatic Transceiver Power Control) is a function for effective-ly reducing the interference probability in your network. The output powerfrom the transceiver is automatic controlled. If the regulation loop for theATPC stops functioning, an alarm is generated. This alarm can be delayed.The output power should be muted when the frequency setting is changed.The Power Settings configuration sheet can be opened from the Config-uration context menu of the ODU node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the ODU node in the Explorerview and then selecting Edit Power Settings from the Configurationmenu.
Figure VIII-32 Power Settings Configuration Sheet
B4008 Rev. M 329
Fast Ethernet Configuration
Fields: Denomination: Description:
RF-INPUT- dBm The upper threshold value for when toWARNING- generate a RF Input Level Warninghigh (Alarm nr. 1504).
RF-INPUT- dBm The lower threshold value for when toWARNING- generate a RF Input Level Warninglow (Alarm nr. 1504).
Manual dBm The output power level used when ATPCoutput level not is activated.
Mute output Mutes the output power. No output powerpower is sent.
Maximum dBm Maximum output power foroutput power transmitting.
Manual Disable ATPC.TransmitOutput Power(MTPC)
Automatic Enable ATPC.TransmitOutput Power(ATPC)
Reference dBm The wanted input level when ATPC isinput level activated.
Default dBm Set the Power Level to use when anoutput level ATPC alarm occurs.
ATPC alarm seconds The ATPC alarm can be delayed adelay certain number of seconds.
330 B4008 Rev. M
CityLink
10.3 Frequency SettingsThe Duplex Distance between the Rx and Tx band is fixed. The user can setthe Tx frequency by clicking on the frequency slots. Since the duplexdistance is fixed the Rx frequency will be automatically set. The corre-sponding Tx and Rx frequency must be set in the opposite NE.
NEW-NMS/-Configurator receives the frequency plan from the NE.When no NE is connected (off-line) no frequency plan will be shown.
The output power should be muted when the frequency setting is changed.
The Frequency configuration sheet can be opened from the Configura-tion context menu of the ODU node in the Explorer view. The sheet canalso be invoked by selecting (highlighting) the ODU node in the Explorerview and then selecting Edit Frequency from the Configurationmenu.
Figure VIII-33 Frequency Configuration Sheet
B4008 Rev. M 331
Fast Ethernet Configuration
Fields: Denomination: Description:Frequency plan Choose the wanted frequency plan.
The frequency plan must.correspond to your transceiver.
TX Frequency MHz The used Tx Carrier frequency.RX Frequency MHz The used Rx Carrier frequency.Coding TCM or TCM+RS The coding schemeModulation The modulation scheme used with
this frequency plan.Data rate STM-1 or STM-0Channel spacing MHz The distance between the channels
in this frequency plan.Duplex Distance MHz The distance between the Tx and
the Rx carrier frequency.Innermost MHz The distance between the highestspacing frequency in lower half and the low-
est frequency in the upper half ofthe frequency plan.
Compensation Digital filters in the Modem Boardfilter compensating for RF Filter and
branching characteristics.TX Frequency MHz Tx Lower sideband frequency forBand, Min this frequency plan.TX Frequency MHz Tx Upper sideband frequency forBand, Max this frequency plan.RX Frequency MHz Rx Lower sideband frequency forBand, Min this frequency plan.RX Frequency MHz Rx Upper sideband frequency forBand, Max this frequency plan.Status The result of the last frequency
change operation (unknown, ok,executing, failed).
Reset Modem When this item is checked themodem will be reset when applyingselected frequency data. Only to beused when changing frequency plan.
NOTE!Both the IDU and the ODU must be rebooted after a change of frequency and/or Reed Solomon code. This is done by disconnecting and reconnectingpower to the IDU.
332 B4008 Rev. M
CityLink
11.0 Performance11.1 G826 Performance
G.826 is an ITU-T quality recommendation for SDH networks.The Network Element has several registers for collecting G.826 perform-ance data. The G.826 data is divided into three categories; G.826 15min,G.826 Day and G.826 Month and they show the B1 measurements for 16periods of the category. (4 hours of 15min data, 16 days and 16 months areavailable in the NE).
The G-826 Performance configuration sheet can be opened from thePerformance context menu of the Element node in the Explorer view. Thesheet can also be invoked by selecting (highlighting) the Element node inthe Explorer view and then selecting Performance Registers from theMain menu.
Figure VIII-34 G-826 Performance Configuration Sheet
B4008 Rev. M 333
Fast Ethernet Configuration
Fields: Description:Time interval The interval of the measurement (15 min., day, month).Period The sequence number of the performance register.
Register 0 is the running measurement, register 1 is thelatest completed measurement.
SES Severely Errored Seconds. The number of one-secondperiods which contains > 30% errored blocks or at leastone Severely Disturbed.
UAS The number of UnAvailable Seconds. A period of un-available time begins at the onset of 10 consecutive SESevents. These ten seconds are considered to be a part ofthe unavailable time. A new period of available timebegins at the onset of ten consecutive non-SES events.These 10 seconds are considered to be part of availabletime.
BBE The number of Background Block Errors. An erroredblock not occurring as part of an SES.
ES Errored Second. The number of one second periodswith one or more errored blocks.
Start Time The start time of the measurement period.Status Status of the counter.
334 B4008 Rev. M
CityLink
11.2 Port PerformanceThe Repeater port information property sheet presents performance anderror statistics for the individual ports on the Network Element. Eachentry in the table contains information for a single port. The data aregathered from the RFC-2108 MIB.
The Port Performance configuration sheet can be opened from thePerformance context menu of the IDU node in the Explorer view.
Fields : Description:Readable frames Please refer to RFC-2108 MIB.Readable octets Please refer to RFC-2108 MIB.Runts Please refer to RFC-2108 MIB.Late events Please refer to RFC-2108 MIB.Autopartition Please refer to RFC-2108 MIB.Total errors Please refer to RFC-2108 MIB.
Figure VIII-35 Port Performance Configuration Sheet
B4008 Rev. M 335
Fast Ethernet Configuration
11.3 Repeater PerformanceThe Repeater Information Property sheet presents Ethernet performance.The figures presented are based on the performance of every port on theNetwork Element. Each entry in the table contains information about asingle non-trivial repeater.The data are gathered from the RFC-2108 MIB.
The Repeater Performance configuration sheet can be opened from thePerformance context menu of the IDU node in the Explorer view.
Fields: Description:Tx Collisions Please refer to RFC-2108 MIB.Total Frames Please refer to RFC-2108 MIB.Total errors Please refer to RFC-2108 MIB.Total octets Please refer to RFC-2108 MIB.
Figure VIII-36 Repeater Performance Configuration Sheet
336 B4008 Rev. M
CityLink
12.0 Fault12.1 NE Alarm Log
The NE Alarm Log property sheet displays the settings and content of theNE alarm log.The NE Alarm Log configuration sheet can be opened from the contextmenu of the Element node in the Explorer view. The sheet can also beinvoked by selecting (highlighting) the Element node in the Explorerview and then selecting NE Log Manager from the Fault menu.
When pressing View in the NE Alarm Log Manager, a dialog box isdisplayed prompting for the number of records to retrieve.
Controls: Options: Description:Log full action Wrap or Halt Actions to take when the log is full.Max. number - The number of entries theNE alarmof events log can hold.Number of events - Current number of log entries.
Figure VIII-37 NE Alarm Log Configuration Sheet
Figure VIII-38 Number of Records Dialog Box
B4008 Rev. M 337
Fast Ethernet Configuration
13.0 Security13.1 Security Log
CityLink Fast Ethernet has an internal security log that can contain up to1000 events. To view the local security log, select a CityLink Fast Ethernetobject (in a map or explorer view), and select the NE Security Logcommand either from the context menu or from the Security main menu.
Fields: Description:Security Log Index The index of the Security logSecurity log entry text A descriptive text of the event.Security log entry time The time of the event.
Figure VIII-39 Security Log
338 B4008 Rev. M
CityLink
SNMP & MIB Description
14.0 General• SNMP = Simple Network Management Protocol
– Open internet protocol, requires IP connection.• MIB = Media Information Base
– File describing all details about the equipment.– This file must be copied into SNMP-manager
15.0 Supported MIB’sThe CityLink Fast Ethernet embedded application supports the followingMIBs
Name Description Defined inNERA-FAST-ETHERNET-MIB Specific management Nera_Clip.mib
of CityLink FastEthernet devices.
NERA-MIB General management Nera.mibof Nera radioequipment.
SNMP-REPEATER-MIB General management/ RFC 2108monitoring ofrepeater units.
RFC1213-MIB (mib2) General management RFC 1213of network devices.
NERA-FAST-ETHERNET-MIB purposes:• To support common management task through SNMP.• To provide network management with an acceptable security level.• To support industry standard MIB definitions where appropriate.• To create a modular MIB design to reflect the modularity of the agent
software.• To facilitate future updates and configuration changes.• To conform to the established conventions of the “NERA-MIB” MIB.
B4008 Rev. M 339
Fast Ethernet Configuration
16.0 MIB OverviewThe MIB is separated into 8 sub-modules as shown below.
Figure VIII-40 MIB Overview
340 B4008 Rev. M
CityLink
16.1 UnitThis unit contains entries related to overall system properties. Thisincludes system time, status, transmission settings and managementaddressing
Figure VIII-41 MIB Sub-modules, Unit
B4008 Rev. M 341
Fast Ethernet Configuration
16.2 IDUThis module provides configuration and monitoring of IDU hardwareinterfaces. This includes the Ethernet ports, 2Mbit/s ports, 64kbit/s portsand the auxiliary port. The module also contains the global error levellimits for the IDUs data inputs.
Figure VIII-42 MIB Sub-modules, IDU
342 B4008 Rev. M
CityLink
16.3 ODUThis module contains the ODU specific control settings and operationalstatus. The ODU functional capabilities are obtainable through the “capa-bilities” sub module.
Figure VIII-43 MIB Sub-modules, ODU
B4008 Rev. M 343
Fast Ethernet Configuration
16.4 Test ManagerThis Module provides means to perform test functions on the equipment.The design provides an extensible way of generating traffic loops onvarious interfaces and test points. It is possible at run time to query forpossible loop settings and perform tests without previous knowledge ofthe test loops provided by the equipment.
Figure VIII-44 MIB Sub-modules, Test Manager
344 B4008 Rev. M
CityLink
16.5 Performance ManagerThe module provides means of access to traffic performance data. Thecurrent design only supports the G826 B1 measurement type but thelayout of the module makes feasible to extend this in future versions.
Figure VIII-45 MIB Sub-modules, Performance Manager
B4008 Rev. M 345
Fast Ethernet Configuration
16.6 Fault ManagerThis module is an extension to the fault management framework definedby the “NERA-MIB” specification. It supplies an extension to the previousfault log which is more configurable than the previous. In addition itsupplies new functionality where a manager can query all supported alarmtypes from the equipment and retrieve descriptions and node informationfor each one. This will reduce the linking between the managementsoftware and the agent considerable.
Figure VIII-46 MIB Sub-modules, Fault Manager
B4008 Rev. M 347
Troubleshooting
Troubleshooting
SECTION IX
348 B4008 Rev. M
CityLink
1.0 GeneralThis Section describes two ways of troubleshooting; by means of LEDSlocated at the In Door Unit's front panel and by means of NEW-NMSConfigurator.
2.0 Description of Alarm LEDs2.1 IDU Alarm LEDs
The functions of the alarm LEDs are as follows:CRITICAL Red Will be activated when one or more
critical alarms are activatedMAJOR Red Will be activated when one or more
major alarms are activatedMINOR Red Will be activated when one or more
minor alarms are activatedWARNING Orange Will be activated when one or more
warnings are activatedPOWER ON Green Will be on when main power is > 39V
2.2 HSB-IDU Alarm LEDs and Switch IndicatorsThe functions of the alarm LEDs are as follows:CRITICAL Red Will be activated when one or more
critical alarms are activatedMAJOR Red Will be activated when one or more
major alarms are activatedMINOR Red Will be activated when one or more
minor alarms are activatedWARNING Orange Will be activated when one or more
warnings are activatedPWR 1 Green Will be on when main power is > 39VPWR 2 Green Will be on when main power is > 39V
The functions of the Switch indicators are as follows:RX DIRA Green Will be on when receiving on A-branchRX DIRB Green Will be on when receiving on B-branchTX DIRA Green Will be on when transmitting on A-branchTX DIRB Green Will be on when transmitting on B-branch
B4008 Rev. M 349
Troubleshooting
2.3 LEDs on Line Interface Plug-in BoardsG.703 Line interface:Green LED is activated when input signal is present.
Multimode Fiber Line interface:Green LED is activated when input signal is present.
Singelmode Fiber Line interfaces (1310 Nm and 1550 Nm):Green LED is activated when input signal is present.
CAT-5 UTP Line interface:Bicolor LED. Emits red when input signal is present and loss of frame(LOF) alarm is activated. Emits green when input is normal and LOF is low.
3.0 Troubleshooting by NEW-NMS Configurator3.1 Introduction
Fault management is the process of locating and correcting networkproblems or faults. Fault management is possibly the most important taskin network management. It consists of identifying the occurrence of afault, isolating the cause of the fault and correcting it if possible. The faultmanagement increases the network reliability by giving the networkoperator a tool that quickly detects problems and initiates recoveryprocedures.
NEW contains functions for acquisition, presentation and storage ofalarms and events from the network to be managed.
3.2 Information AcquisitionIn order to detect faults, information must be gathered from the network.The state of the network is monitored using two different methods.
3.2.1 PollingThe various network elements should be polled on a regular basis, so thatchanges in Network Elements (NE) are detected and network connectivityis checked. Which NE to poll, the polling rate and what to be polled for aspecific NE is user definable.
350 B4008 Rev. M
CityLink
3.2.2 Event NotificationIn addition to polling, some NEs have the ability to spontaneously reportevents. The NEW will gather this information in addition to polling. Thisfeature will decrease the managers response time to network eventsconsiderably.
3.3 Alarm PresentationIn all views, where network information is presented, colors are used toindicate the alarm severity status of the NEs. To easily identify the statusof the NEs, all alarms are classified according to their severity. Each alarmseverity class has a color. In the different views, the NEs change colorsaccording to the color of their most severe alarm. The alarm classifica-tions are described in the table below.
Severity Colour Description(default)
Normal Green No alarms or warning have been reportedfrom the NE.
Warning Yellow Indicates the detection of a potential orimpending service-affecting fault, before anysignificant affects have been felt. Actionshould be taken to further diagnose andcorrect the problem in order to prevent itfrom becoming a more serious service-affecting fault.
Minor alarm Dark Yellow Indicates the existence of a non-service-affecting fault condition and that correctiveaction should be taken in order to prevent amore serious fault.
Major alarm Orange Signifies that a service-affecting conditionhas occurred and urgent corrective action isrequired.
Critical alarm Red The most severe alarm. It signifies that aservice-affecting condition has occurred andan immediate corrective action is required.
No contact Blue Indicates that no contact is achieved with theNE. The communication settings should bechecked in order to obtain contact with theelement.
Misconfigured Magenta The NE has not been properly configured.
B4008 Rev. M 351
Troubleshooting
3.4 Visual Alarm NotificationThere are four different ways of monitoring alarms in NEW. These methodsare described in the following subchapters. The NEW context sensitive helpsystem offers a more comprehensive support on all features in the NEWprogram.
3.4.1 Alarms on a Tree node/leaf in the Explorer viewThe Explorer View is opened by selecting Explore Net from the View Menu.Figure IX-1 shows an example of the Explorer view.
The Explorer View shows the Network information in a logical manner. EachNE is divided into two main branches; a Transmission branch and anEquipment branch. The sub-branches and leaves under the Transmissionbranch concern the transmission aspects of the NE. The sub-branches andleaves under the Equipment branch concern the physical equipment of theNE.
Figure IX-1 Example of Explorer View
352 B4008 Rev. M
CityLink
The Explorer view use the severity colours to indicate alarm events. Thealarms are presented in a hierarchical manner. The colour of the mostsevere alarm is inherited from the leaf where the alarm was identified, toall branch leaves up to the section symbol. E.g. the section and NE symbolswill always show the alarm colour of the most severe alarm identified inthe sub-branches in the Explorer view.
By pressing the right mouse button on any nodes/leaves in the ExplorerView and selecting Current Alarms from the context menu, a CurrentAlarm List (ref. Appendix III) is opened showing all alarms Hierarchicalbelow the selected leaf.
3.4.2 Alarms on a Node symbol in the Map viewThe Map View is opened by selecting Map Navigator from the ViewMenu. Follow the instructions in the Help file to create a map. Figure IX-2 shows an example of the view.
The Map View shows the Network information in a physical manner. EachNE is showed as an NE icon. Graphic-files can be added as backgroundimages in the view. NE icons grouped together with bindings formnetworks. The NE icons change their severity colours according to thecurrent most severe alarm of the NE.
Figure IX-2 Example of Map View
By pressing the right mouse button on a NE icon in the Map View andselecting Alarms from the context menu, a Current Alarm List (ref.Appendix III) is opened showing all alarms of the NE.
B4008 Rev. M 353
Troubleshooting
3.4.3 Viewing Alarms in the Current Alarms ViewThe Current Alarm View can be opened by selecting Current Alarms fromthe Fault Menu. Figure IX-3 shows an example of the Current Alarms List.Each alarm is listed as a row in the list as shown in Table IX-1.
The Current Alarms List can also be opened from both the Explorer Viewand the Map View by selecting Current Alarms from the right-mouse-button-click context menu. The filter is then automatically set up to showonly the alarms hierarchically below the node/leaf the alarm list wasopened from.
Figure IX-3 Example of Current Alarms
Fields DescriptionSeverity The severity of the alarmAlarm text A short description of the alarmNode The name of the node where the alarm occurred
Table IX-1 Fields in the Current Alarms List
Alarms can also be logged to files. Consult the NEW NMS Manual or theNEW NMS Help system for further information.
354 B4008 Rev. M
CityLink
4.0 Cable FaultIf a cable fault is indicated, it indicates that the microprocessor communica-tions between the IDU and ODU have failed. The fault is most probably withthe cable connection. It may be open or shorted. Disconnect the cable fromthe IDU and leave the ODU connected. Measure the DC cable resistancebetween the centre pin and the outer conductor of the N-type connectorterminating the cable by means of a multi-meter.
If resistance is in the order of some hundreds kΩΩΩΩΩ to a few MΩΩΩΩΩ:Probably no cable fault.Replace IDU or ODU, one at the time. If alarm persists, swap the replaced unitfor the original and replace the other unit.
If resistance is less than some hundreds kΩΩΩΩΩ:Probably cable or connector damage. Check the cable and connectors at bothends for defects or for reasons that would cause the problem. RemeasureDC resistance, now with both cable ends disconnected. The resistanceshould be “open circuit” and if not replace the entire cable run, terminatingwith new N-type connectors.
If resistance is immeasurable (high impedance):Typically reasons are connectors not terminated correctly or cable cut.Check the cable and connectors at both ends for defects or for reasons thatwould cause the problem. Remeasure DC resistance, with the outer endstill connected to the ODU. If still immeasurable impedance, replace theentire cable run, terminating with new N-type connectors.
B4008 Rev. M 355
Appendices
Appendices
SECTION X
356 B4008 Rev. M
CityLink
Appendix I: IDU / HSB-IDU Interface Description
Figure X-1 CityLink IDU
POW
ERC
onne
ctor
: PO
WER
D-S
UB 2
-PIN
Cab
le :
UWM
K50
51
PHO
NE
Con
nect
or :
RJ-4
5 8-
PIN
Kit
: 4CZ
5
Hot
Sta
ndby
Inte
rcon
nect
ion
Con
nect
or :
68-P
IN V
HD
CI r
ecep
tacl
eC
able
: 87
W50
66-1
A
64kb
it/s
SER
VIC
E C
HA
NN
EL (G
.703
)C
onne
ctor
: R
J45
8-PI
NC
able
: U
WM
K307
7
LOC
AL C
RAF
T TE
RMIN
AL (R
S232
)C
onne
ctor
: D
-SU
B 9
-PIN
MAL
EC
able
: U
WM
K31
23
SAFE
TYG
RO
UND
OD
U IN
TER
FAC
EN
-TYP
E FE
MAL
E
ALAR
M &
AU
XILL
ARY
FUN
CTI
ON
SC
onne
ctor
: D-
SUB
25-
PIN
FEM
ALE
Cab
le :
UW
MK
3076
64kb
it/s
SER
VIC
E C
HA
NN
EL (V
.11)
Con
nect
or :
RJ4
5 8-
PIN
Cab
le :
UW
MK
3077
-48V
DC
64kb
/sG
.703
2Mb/
sW
aysi
deSV
CE
Ext.
1Ph
one
64kb
/sV.
112M
Hz
Sync
.SV
CE
Ext.
210
Bas
eTLA
NID
U -
HSB
INTF
CC
ALL
ALM
& A
UX
LCT
NI 2
NI 1
CR
ITIC
AL
MAJ
OR
MIN
OR
WA
RN
ING
POW
ER
155
Mb/
s LI
NE
2Mbi
t/s W
AYS
IDE
CH
AN
NEL
Con
nect
or :
RJ4
5 8-
PIN
Cab
le :
87W
5097
-2A,
10m
pat
ch c
able
2MH
z S
YNC
(Lat
er re
leas
e)
10 B
aseT
Eth
erne
tO
ff th
e sh
elf s
tand
ard
ethe
rnet
cab
le
SERV
ICE
CH
ANNE
L EX
TEN
SIO
N 1
Con
nect
or :
RJ-4
5 8-
PIN
Cab
le :
87W
5097
-1A
SER
VIC
E C
HAN
NEL
EXTE
NSI
ON
2C
onne
ctor
: RJ
-45
8-PI
NC
able
: 87
W50
97-1
A
Slot
for o
ptio
nal L
ine
Inte
rfac
e Pl
ug-In
Boa
rd
Ref
. Fig
. X-6
CO
LLEC
TIVE
CAL
L
Slot
for o
ptio
nal
Exte
nsio
n B
oard
PWR
NET
WO
RK
INTE
RFA
CE
(RS4
85)
Con
nect
or :
D-S
UB
9-P
IN F
EMAL
EC
able
: UW
MK
3078
, UW
MK
3079
B4008 Rev. M 357
Appendices
Figure X-2 CityLink HSB-IDU
POW
ERC
onne
ctor
: PO
WER
D-S
UB
2-P
INC
able
: U
WM
K50
51
PHO
NEC
onne
ctor
: R
J-45
8-P
INK
it : 4
CZ5
Hot S
tand
by In
terc
onne
ctio
nCo
nnec
tor :
68-
PIN
VH
DCI
rece
ptac
leCa
ble
: 87W
5066
-1A
64kb
it/s
SER
VIC
E C
HA
NN
EL (G
.703
)C
onne
ctor
: R
J45
8-PI
NC
able
: U
WM
K30
77
LOC
AL C
RAF
T TE
RM
INAL
(RS2
32)
Con
nect
or :
D-S
UB 9
-PIN
MAL
EC
able
: U
WM
K31
23
SAFE
TYG
RO
UND
ALAR
M &
AU
XILL
ARY
FUN
CTI
ON
SC
onne
ctor
: D
-SU
B 2
5-PI
N F
EMAL
EC
able
: UW
MK
3076
64kb
it/s
SER
VIC
E C
HA
NN
EL (V
.11)
Con
nect
or :
RJ4
5 8-
PIN
Cab
le :
UWM
K30
77
-48V
DC
64kb
/sG
.703
2Mb/
sW
aysi
deSV
CE
Ext.
1Ph
one
64kb
/sV.
112M
Hz
Sync
.SV
CE
Ext.
210
Bas
eTLA
NID
U -
HSB
INTF
CCA
LLAL
M &
AU
XLC
TN
I 2
NI 1
CR
ITIC
AL
MAJ
OR
MIN
OR
WA
RN
ING
POW
ER 2
155
Mb/
s LI
NE
1
2Mbi
t/s W
AYS
IDE
CH
AN
NEL
Con
nect
or :
RJ4
5 8-
PIN
Cab
le :
87W
5097
-2A,
10m
pat
ch c
able
2MH
z S
YNC
(Lat
er re
leas
e)
10 B
aseT
Eth
erne
tO
ff th
e sh
elf s
tand
ard
ethe
rnet
cab
le
SER
VIC
E C
HAN
NEL
EXT
ENSI
ON
1C
onne
ctor
: R
J-45
8-P
INC
able
: 87
W50
97-1
A
SERV
ICE
CHAN
NEL
EXT
ENSI
ON
2C
onne
ctor
: R
J-45
8-P
INC
able
: 87
W50
97-1
A
Slot
for o
ptio
nal L
ine
Inte
rfac
e Pl
ug-In
Boa
rd
Ref
. Fig
. X-6
RX
DIR
.AR
X D
IR.B
TX D
IR.A
TX D
IR.B
CO
LLEC
TIVE
CAL
L
Slot
for o
ptio
nal
Exte
nsio
n B
oard
POW
ER 1
2
PWR
NET
WO
RK
INTE
RFAC
E (R
S485
)C
onne
ctor
: D-
SUB
9-P
IN F
EMAL
EC
able
: U
WM
K30
78 ,
UW
MK
3079
358 B4008 Rev. M
CityLink
OD
U-4
8VD
C
64kb
/sG
.703
2Mb/
sW
aysi
deSV
CE
Ext.
1Ph
one
64kb
/sV.
112M
Hz
Sync
.SV
CE
Ext.
210
Bas
eTLA
NID
U -
HSB
INTF
CC
ALL
ALM
& A
UX
LCT
NI 2
NI 1
POW
ER
155
Mb/
s LI
NE
PWR
10B
ase-
T/10
0Bas
e-TX
T1/E
1SI
GNA
LSI
GNA
L
CR
ITIC
AL
MAJ
OR
MIN
OR
WA
RN
ING
POW
ERCo
nnec
tor :
PO
WER
D-S
UB
2-P
INCa
ble
: UW
MK
5051
PHO
NE
Not
use
d fo
r City
Link
Fas
t Eth
erne
t
Hot S
tand
by In
terc
onne
ctio
nNo
t use
d fo
r City
Link
Fas
t Eth
erne
t
NET
WO
RK
INTE
RFA
CE
(RS4
85)
Not
use
d fo
r City
Link
Fas
t Eth
erne
t
64kb
it/s
SER
VIC
E C
HA
NN
EL (G
.703
)Co
nnec
tor :
RJ4
5 8-
PIN
Cabl
e : U
WM
K30
77
LOC
AL
CR
AFT
TER
MIN
AL
(RS2
32)
Con
nect
or :
D-S
UB 9
-PIN
MAL
ECa
ble
: UW
MK3
123
SAFE
TYG
RO
UN
D
OD
U IN
TER
FAC
EN
-TYP
E FE
MAL
E
ALAR
M &
AU
XILL
ARY
FUNC
TIO
NS
Conn
ecto
r : D
-SUB
25-
PIN
FEM
ALE
Cabl
e : U
WM
K30
76
64kb
it/s
SER
VIC
E C
HA
NN
EL (V
.11)
Conn
ecto
r : R
J45
8-PI
NCa
ble
: UW
MK
3077
2Mbi
t/s W
AYS
IDE
CH
AN
NEL
Conn
ecto
r : R
J45
8-PI
NCa
ble
: 87W
5097
-2A,
10m
pat
ch c
able
2MH
z S
YNC
(Lat
er re
leas
e)
10B
aseT
Eth
erne
tO
ff th
e sh
elf s
tand
ard
ethe
rnet
cab
le
SER
VIC
E C
HA
NN
EL E
XTEN
SIO
N 1
Not
use
d fo
r City
Link
Fas
t Eth
erne
t
SER
VIC
E C
HA
NN
EL E
XTEN
SIO
N 2
Not
use
d fo
r City
Link
Fas
t Eth
erne
tCO
LLEC
TIVE
CA
LLN
ot u
sed
for C
ityLi
nk
Fast
Eth
erne
t
Slot
for o
ptio
nal L
ine
Inte
rfac
e Pl
ug-In
Boa
rd
Ref
. Fig
. X-6
10B
ase-
T/10
0Bas
e-TX
Eth
erne
tO
ff th
e sh
elf s
hiel
ded
twis
ted
pair
ethe
rnet
cab
le
TRIB
UTA
RY
T1/E
1 IN
TER
FAC
E (2
Mbi
t/s o
r 1.5
Mbi
t/s)
Conn
ecto
r : R
J45
8-PI
NCa
ble
: 87W
5097
-2A,
10m
pat
ch c
able
Figure X-3 CityLink Fast Ethernet IDU
B4008 Rev. M 359
Appendices
INPG.703
OUT
INP
MM Fiber
INP
SM FiberOUT INP
CAT-5 UTP
INP
Figure X-4 Optional Line Interface Plug-in Boards
155 Mbit/s STM-1G.703, 75ΩΩΩΩΩConnector : DIN47297, 1.0/2.3mmCable : UWMH3080
155 Mbit/s STM-1CAT-5, UTPConnector: RJ45 (FCC-8 compl.), 8-pin ConnectorCable alt.1: 87W5111-CAT5E02S, 2m straight patch cableCable alt.2: 87W5111-CAT5E02C, 2m crossed patch cable
1310 nm SMF and 1550 nm SMFOptical InterfaceConnector: LCCable: 87W5080-SCxx/LCxx/FCxx
1310 nm MMFOptical InterfaceConnector: MT-RJCable: 87W5078-SCxx/MTRJxx/STxx/FCxx
360 B4008 Rev. M
CityLink
Figure X-5 Optional Extension Boards Boards
Optional Extension Boards
TRIBUTARY
OUT IN OUT IN OUT IN
DS1-0 DS3/E3-1 DS3/E3-2 DS3/E3-3SIGNAL0123
Line ExtensionSTM1 / STS-3 (155Mb/s)
G.703INP OUT
21x2Mbit/s Extension Board:
STM1 Extension Board:
DS3/E3 Extension Board:
B4008 Rev. M 361
Appendices
Pin no. 8Pin no. 1
Pin no. 8 Pin no. 1
Power Connector
0V STATION GROUND
-48VDC
Figure X-6 IDU Power Connector Pinout
RJ-45 ConnectorsWith reference to Figure X-7, several connector pin-outs will be described.Note that the upper connector pins are reversed with respect to the lowerconnector pins, i.e. the lower plug is “mirrored”. Refer to Figure X-1-3 forlocation of 2-by-4 port RJ-45.
IN DOOR UNIT'SFRONT VIEW
Figure X-7 RJ-45 (P5001A-D) connector detail.
A B C D
U
L
IN DOOR UNIT'SFRONT VIEW
(FEMALE )
(MALE )
362 B4008 Rev. M
CityLink
64kbit/s G.703 Jack, RJ-45 Connector
Pin. no: Function:1UA TxD- (Neg. Tx. data)2UA TxD+ (Pos. Tx. data)3UA TxC+ (Pos. Tx. clock)4UA TxC- (Neg. Tx. clock)5UA RxD+ (Pos. Rx. data)6UA RxD- (Neg. Rx. data)7UA RxC+ (Pos. Rx. clock)8UA RxC- (Neg. Rx. clock)
Table X-1 64kbit/s G.703 Jack, 8-PIN Pinout
64kbit/s V.11 Jack, RJ-45 Connector
Pin. no: Function:1LA TxD- (Neg. Tx. data)2LA TxD+ (Pos. Tx. data)3LA TxC- (Neg. Tx. clock)4LA TxC+ (Pos. Tx. clock)5LA RxD- (Neg. Rx. data)6LA RxD+ (Pos. Rx. data)7LA RxC- (Neg. Rx. clock)8LA RxC+ (Pos. Rx. clock)
Table X-2 64kbit/s V.11 Jack, 8-PIN Pinout
2Mbit/s Wayside Jack, RJ-45 Connector
Pin. no: Function:1UB IND+ (Pos. Rx. data)2UB IND- (Neg. Rx. data)3UB shield4UB OUTD+ (Pos. Tx. data)5UB OUTD- (Neg. Tx data)6UB shield7UB Not Connected8UB Not Connected
Table X-3 2Mbit/s Wayside Jack, 8-PIN Pinout
B4008 Rev. M 363
Appendices
2.048 MHz SYNC Jack, RJ-45 Connector
Pin. no: Function:1LB INP+ (Pos. Rx. pulse)2LB INP- (Neg. Rx. pulse)3LB shield4LB OUTP+ (Pos. Tx. pulse)5LB OUTP- (Neg. Tx pulse)6LB shield7LB Not Connected8LB Not Connected
Table X-4 2.048 MHz SYNC Jack, 8-PIN Pinout
Service Channel Extension 1 and 2 Jacks, RJ-45 Connector
Pin. no: Function:1UC OE1_INP_A2UC OE1_INP_B3UC OE1_OUT_A4UC OE1_OUT_B5UC CALL_INP6UC CALL_OUT7UC CTRL_INP8UC CTRL_OUT
Table X-5 Service Channel Extension 1 Jack, 8-PIN Pinout
Pin. no: Function:1LC OE2_INP_A2LC OE2_INP_B3LC OE2_OUT_A4LC OE2_OUT_B5LC CALL_INP6LC CALL_OUT7LC CTRL_INP8LC CTRL_OUT
Table X-6 Service Channel Extension 2 Jack, 8-PIN Pinout
364 B4008 Rev. M
CityLink
Service Phone Jack, RJ-45 Connector
Pin. no: Function:1UD Not Connected2UD Not Connected3UD TELA4UD MIC+5UD MIC-6UD TELB7UD Not Connected8UD LOOP_OE
Table X-7 Service Phone Handset Connector, 8-PIN Pinout
10Base-T (“TP-LAN”) Jack, RJ-45 Connector (normal)
Pin. no: Function:1LD TPTX+ (Pos. Tx. data)2LD TPTX- (NEG. Tx. data)3LD TPRX+ (Pos. Rx. data)4LD Not Connected5LD Not Connected6LD TPRX- (Neg. Rx. data)7LD Not Connected8LD Not Connected
Table X-8 10Base-T, 8-PIN Pinout
10Base-T / 100Base-TX Jack, RJ-45 Connector (uplink)(Used only in Fast Ethernet configuration)
Pin. no: Function:1LD TPRX+ (Pos. Rx. data)2LD TPRX- (NEG. Rx. data)3LD TPTX+ (Pos. Tx. data)4LD Not Connected5LD Not Connected6LD TPTX- (Neg. Tx. data)7LD Not Connected8LD Not Connected
Table X-9 10Base-T / 100Base-TX, 8-PIN Pinout
B4008 Rev. M 365
Appendices
NI1 and NI2, Network Interface Connector Detail
PIN 1PIN 5
PIN 9 PIN 6
Figure X-9 “NI1” and “NI2” D-SUB 9 PIN Pinout
NI1 and NI2 D-SUB Signal Name Signal Description9-PIN FEMALE1 RxD- Data Input2 RxD+ Data Input3 GND Signal Ground.
Normally this pin shallnot be connected.
4 TxD+ Data Output5 TxD- Data Output6 RxC- Clock Input7 RxC+ Clock Input8 TxC+ Clock Output9 TxC- Clock Output
Table X-10 “NI1” and “NI2” D-SUB 9-PIN Pinout
IDU to HSB Interface ConnectorThe connector is 68 pin VHDCI receptacle. This is a shielded connectortype and the screen is terminated to chassis ground.
Pos. 35
Pos. 1Pos. 34
Figure X-8 IDU to HSB-IDU Interface Connector
IN DOOR UNIT'SFRONT VIEW
IN DOOR UNIT'SFRONT VIEW
PIN 34 PIN 1
PIN 35
366 B4008 Rev. M
CityLink
ALM & AUX Connector Detail
Figure X-10 “ALM & AUX” D-SUB 25-PIN Pinout
IDUFRONTVIEW
PIN 13 PIN 1
PIN 14PIN 25
ALM & AUX D-SUB Signal Name Signal Description 25-PIN FEMALE
1 USER1A Relay output 1A2 USER1B Relay output 1B3 USER2A Relay output 2A4 USER2B Relay output 2B5 USER3A Relay output 3A6 USER3B Relay output 3B7 USER4A Relay output 4A8 USER4B Relay output 4B9 ALM1 Alarm input 1 (TTL level)10 AGND Analog GND*11 ALM2 Alarm input 2 (TTL level)12 ALM3 Alarm input 3 (TTL level)13 AGND Analog GND*14 AGND Analog GND*15 ALM4 Alarm input 4 (TTL level)16 AGND Analog GND*17 ALM5 Alarm input 5 (relay input)18 AGND Analog GND*19 ALM6 Alarm input 6 (relay input)20 ALM7 Alarm input 7 (relay input)21 ALM8 Alarm input 8 (relay input)22 ERRP_V11+ Error pulses (V.11 output)**23 ERRP_V11- Error pulses (V.11 output)**24 ERRP_OPEN_COL Error pulses
open collector output25 ERRP_OPTO Error pulses opto
coupler driver outputTable X-11 “ALM & AUX” D-SUB 15-PIN Female Pinout
* Analog GND is floating relative scussi GND.** Selectable from NEW-NMS: B1, B2 or Trellis decoder.
See Section VII Ch.4.4.5.
B4008 Rev. M 367
Appendices
IDUFRONTVIEW
PIN 5PIN 1
PIN 6 PIN 9
LCT Connector Detail
Figure X-11 “LCT” D-SUB 9 PIN male, Pinout
LCT D-SUB Signal Name Signal Description9-PIN MALE1 NC Not Connected2 RxD City Link Data Input3 TxD City Link Data Output4 - Internally connected to pin 65 GND Signal ground6 - Internally connected to pin 47 - Internally connected to pin 88 - Internally connected to pin 79 NC Not connected
Table X-12 “LCT” D-SUB 9-PIN Pinout
368 B4008 Rev. M
CityLink
1D
1A 6A
6D
Figure X-13 21x2Mbit/s Connector Detail
21x2Mbit/s Extension board G.703 Connector DetailsFigures X-12 and X-13 shows the 4 connectors J1001 to J1004 and theirpinout. For location of the 4 connectors on the IDU; see Figur X-5.
For configuration of 21x 2.048 Mb/s input- and output- signals in connec-tors and cables , see Table X-13.
Figure X-12 The 21x2 Mb/s interface connectors from left to right,IDU front view.
J1001 J1002 J1003 J1004
IDUFRONTVIEW
B4008 Rev. M 369
Appendices
• Input, A / Output, A, refers to the positive pulse of the signal.• Input, B / Output, B, refers to the negative pulse of the signal.
Connector J1001 Connector J1002 Connector J1003 Connector J1004Pin noin
connec-tor
Colourcode ofpairs in
cable2 Mb/sCh. No
Signal 2 Mb/sCh. No
Signal 2 Mb/sCh. No
Signal 2 Mb/sCh. No
Signal
1A Ch.1 Input, A Ch.7 Input, A Ch.13 Input, A Ch.19 Input, A1B
White /Blue Ch.1 Input, B Ch.7 Input, B Ch.13 Input, B Ch.19 Input, B
1C Ch.1 Output, A Ch.7 Output, A Ch.13 Output, A Ch.19 Output, A1D
White /Orange Ch.1 Output, B Ch.7 Output, B Ch.13 Output, B Ch.19 Output, B
2A Ch.2 Input, A Ch.8 Input, A Ch.14 Input, A Ch.20 Input, A2B
White /Green Ch.2 Input, B Ch.8 Input, B Ch.14 Input, B Ch.20 Input, B
2C Ch.2 Output, A Ch.8 Output, A Ch.14 Output, A Ch.20 Output, A2D
White /Brown Ch.2 Output, B Ch.8 Output, B Ch.14 Output, B Ch.20 Output, B
3A Ch.3 Input, A Ch.9 Input, A Ch.15 Input, A Ch.21 Input, A3B
Red /Blue Ch.3 Input, B Ch.9 Input, B Ch.15 Input, B Ch.21 Input, B
3C Ch.3 Output, A Ch.9 Output, A Ch.15 Output, A Ch.21 Output, A3D
Red /Orange Ch.3 Output, B Ch.9 Output, B Ch.15 Output, B Ch.21 Output, B
4A Ch.4 Input, A Ch.10 Input, A Ch.16 Input, A N.c.4B
Red /Green Ch.4 Input, B Ch.10 Input, B Ch.16 Input, B N.c.
4C Ch.4 Output, A Ch.10 Output, A Ch.16 Output, A N.c.4D
Red /Brown Ch.4 Output, B Ch.10 Output, B Ch.16 Output, B N.c.
5A Ch.5 Input, A Ch.11 Input, A Ch.17 Input, A N.c.5B
Black /Blue Ch.5 Input, B Ch.11 Input, B Ch.17 Input, B N.c.
5C Ch.5 Output, A Ch.11 Output, A Ch.17 Output, A N.c.5D
Black /Orange Ch.5 Output, B Ch.11 Output, B Ch.17 Output, B N.c.
6A Ch.6 Input, A Ch.12 Input, A Ch.18 Input, A N.c.6B
Black/Green Ch.6 Input, B Ch.12 Input, B Ch.18 Input, B N.c.
6C Ch.6 Output, A Ch.12 Output, A Ch.18 Output, A N.c.6D
Black /Brown Ch.6 Output, B Ch.12 Output, B Ch.18 Output, B N.c.
Table X-13 Configuration of 21x 2Mbit/s input- and output- signals inconnectors and cables
ADM STM-1 Extension Board ConnectorsThe type and configuration of connectors used for the 155 Mbit/s customerline interface on the Extension Board are the same as used for the G.703 CMIencoded 155 Mb/s customer line interface on the main board in the IDU.
370 B4008 Rev. M
CityLink
Appendix II: ODU Interface Description
ODU/IDU Interface N-connector female for: Transmit and Receive IF,
Modem/Transceiver communication and power supply.
Branching / Antenna Interface PBR320 waveguide (38GHz). PBR220 waveguide (18GHz, 23GHz and 26GHz). PDR120 waveguide (for 13GHz). PBR140 waveguide (for 15GHz). PDR84 waveguide (for 7GHz and 8GHz). Grounding cable for Branching Unit.
B4008 Rev. M 371
Appendices
Appendix III:Alarm List & Alarm DescriptionAlarm Name Description Id Severity BASEBAND LOS Loss Of Signal:
- Optical or electrical CMI 1000 MAJOR
LOF Loss of Frame 1001 MAJOR MS-AIS Alarm indication signal detected.
MS termination only 1002 WARNING
MS-AIS-INS Alarm indication signal is inserted. 1003 MAJOR MS-RDI Remote defect indicator detected.
MS termination only 1004 WARNING
2M-WAYSIDE-INP 2Mbit wayside input is missing. 1005 MINOR 2M-WAYSIDE-AIS-INP 2Mbit wayside input AIS detected. 1006 WARNING TRELLIS-PLL Indicates that the Trellis coder is out of lock.(CNF35C
Asic) 1007 CRITICAL
RT-PLL The Sorp 38,88 MHz PLL is out of lock. 1008 CRITICAL 2M-SYNC Selected synchronisation for Line Transmit direction is
missing. 1009 MINOR
RS-TRACE-MISMATCH Mismatch between configured string and received string 1010 MAJOR LOC Loss of clock (SORP) 1011 CRITICAL BASEBAND DIRECTION RADIO TO LINE
LT-PLL The Line Transmit 155MHz PLL is out of lock. 1100 CRITICAL 2M-WAYSIDE-OUTP-AIS AIS is detected on the Wayside traffic output. 1101 WARNING HBER Indicator for BER > 1e-3 1102 MAJOR LBER Indicator for BER > 1e-6 1103 MINOR EW-BER Indicator for BER > 1e-10 1104 WARNING RF-ID Wrong RF-ID received compared to configuration. 1105 MAJOR MODULATOR IF-MOD Loss of IF 350MHz 1200 CRITICAL DEMODULATOR IF-DEM Loss of INCOMING 140MHz. 1300 CRITICAL OPTICAL INTERFACE TX-OUT The output power has increased 2dB, or the analoge
measurement of PO_MON is outside predefined limits 1400 CRITICAL
LASER-OFF The laser is off. It could be manual shutdown 1401 WARNING BIAS The laser bias is out of limits. Sign of age and degradation 1402 WARNING TRANSCEIVER IF-INP No IF into transceiver 1500 CRITICAL RF-OUT The output power is low 1501 MAJOR LOS-RF-INPUT No signal into receiver. 1502 MAJOR RF-INPUT-WARNING The RF level is either above the upward fading threshold
or The RF level is below the down fading threshold. 1504 WARNING
LO Local Oscillator is out of lock. 1505 MAJOR UNIT-ALM The transceiver is not responding 1506 MAJOR ATPC The regulation loop for the ATPC is not working. Software
generated alarm based on alarm condition on local LOF on Rx and remote LOF on Rx .
1507 MINOR
RF-MUTE The RF transmitter is muted. 1508 WARNING LOOPING-IF-EN The transceiver looping on IF is enabled 1509 WARNING LOOPING-RF-EN The transceiver on RF is enabled.
(If near-end and far end depends on the node where alarm is reported)
1510 WARNING
MISSING_LO_SYNCHRONIZATION XPIC LO synch missing 1511 CRITICAL LO-TUNING-WARNING The LO needs to be tuned 1512 WARNING HIGH_TEMP_POWER_TRANSISTOR 1513 WARNING RF_RX_LOW 1514 MAJOR RF_RX_HIGH 1515 MAJOR NO_CALIBRATION_DATA No calibration data 1516 MAJOR HSB_CABLE_BREAK The cable between the ODUs is broken. This will cause
the switch to perform the TX-switching. 1517 MAJOR
RF_TX_LOW 1518 MAJOR RF_TX_HIGH 1519 MAJOR IF_TX_LOW 1520 MAJOR IF_TX_HIGH 1521 MAJOR POWER_15 1522 WARNING POWER_NEG15 1523 WARNING POWER_6 1524 WARNING POWER_48 1525 WARNING
372 B4008 Rev. M
CityLink
Alarm Name Description Id SeveritySYNTH_HEADER 1526 MAJORSHF_LO 1527 MAJORUHF_TX_LO 1528 MAJORUHF_RX_LO 1529 MAJORDUPLEX_LO 1530 MAJORVHF_LO 1531 MAJORTX_SWITCH_MAN 1532 WARNING
OTHER ALMMEN-AT-WORK Software generated. Operator set men at work before
doing repairs.2000 WARNING
DROP-IN+48V The battery supply voltage is dropped below acceptablelimit
2001 WARNING
BELOW+3.3V Voltage from the DC-DC converter below limit 2002 WARNINGBELOW+5V Voltage from the DC-DC converter below limit 2003 WARNINGBELOW-5V Voltage from the DC-DC converter below limit 2005 WARNINGOVER-CURRENT Detects short current on ODU cable. 2006 MAJORWAYSIDE-LOOP FE Wayside looping Far End 2007 WARNINGWAYSIDE-LOOP NE Wayside looping Near End 2008 WARNINGPRBS-INSERTED PRBS inserted in wayside 2009 WARNINGLOOPING_EN Looping enabled 2010 WARNINGEVENT-LOG-EXC-LIMIT Event log has exceeded the capacity threshold 2011 WARNINGDOWNLOAD-IN-PROGRESS Download of software is under progress. 2012 WARNINGNEED_FREQUENCY A RF unit need to be configured with Tx and Rx
frequency.2013 MAJOR
SECURITY-LOG-EXC-LIMIT Security log has exceeded the capacity threshold 2014 WARNING64K-LOOPING-1 64 kb channel looping Channel1 2015 WARNING64K-LOOPING-2 64 kb channel looping Channel2 2016 WARNINGRTC-LOW BATTERY The battery that powers the Real Time clock is low 2017 WARNING/
MINOR onNL2000
BELOW+48V Voltage from the DC-DC converter below limit 2020 WARNINGBELOW+11V Voltage from the DC-DC converter below limit 2022 WARNINGBELOW+15V Voltage from the DC-DC converter below limit 2023 WARNINGBELOW-15V Voltage from the DC-DC converter below limit 2024 WARNINGMISSING-CALIBRATION-DATA Modem or transceiver are missing their calibration data in
flash2032 MAJOR
FAN-ALARM 2034 WARNINGDEFAULT_SYSTEM_PARAMETERS No system configuration stored in NV config, using default
(stm1,128TCM,28kHz)2035 CRITICAL
DEFAULT_ANALOGE_PARAMETERS No analoge configuration stored in flash, using predefineddefaults.
2036 MAJOR
FAN2-ALARM 2037 WARNINGHSB-RELAY IDUswitch/Transceiver relay mismatch 2200 CRITICALIDUA-ACTIVE Idu A is active in receiving direction 2201 INFOIDUB-ACTIVE Idu B is active in receiving direction 2202 INFOHSB-MANUAL The iduswitch is operated manually 2203 WARNINGCHANNEL-ACTIVE This ODU is active 2216 INFONEED-SW Board needs SW 2221 MAJORBOOT-MONITOR-IN-USE The transceiver is in boot monitor mode 2224 WARNINGBOOT-HW-ERROR-DETECTED Errors detected by boot code when startup. Reported to
app. code2225 MINOR
IDU_A_NEEDS_SW Reported from the IDU A 2226 WARNINGIDU_B_NEEDS_SW Reported from IDU B 2227 WARNINGHDLC_LOC_A The IDU switch has no RX-clock on port A 2228 MAJORHDLC_LOC_B The IDU switch has no RX-clock on port B 2229 MAJORHDLC_LOC The IDU(either A or B) has no RX-clock 2230 MAJORDROP-IN-48V-A The IDU switch power source 1 has a drop 2231 MAJORDROP-IN-48V-B The IDU switch power source 2 has a drop 2232 MAJOR
AUXILIARY ALARMSEXTERN-ALARM-1 Multipurpose port. Configured as
Alarm Output, Alarm Input or Remote Control.External alarm reported if port configured as alarm input.Alarm name configurable from management system.
2500 WARNING
EXTERN-ALARM-2 ref External alarm 1 2501 WARNINGEXTERN-ALARM-3 ref External alarm 1 2502 WARNINGEXTERN-ALARM-4 ref External alarm 1 2503 WARNING
B4008 Rev. M 373
Appendices
Alarm Name Description Id SeverityEXTERN-ALARM-5 ref External alarm 1 2504 WARNINGEXTERN-ALARM-6 ref External alarm 1 2505 WARNINGEXTERN-ALARM-7 ref External alarm 1 2506 WARNINGEXTERN-ALARM-8 ref External alarm 1 2507 WARNINGOUTPUT-ALARM-1 Output alarm reported if auxilary output port configured as
alarm output.2550 INFO
OUTPUT-ALARM-2 ref Output alarm 1 2551 INFOOUTPUT-ALARM-3 ref Output alarm 1 2552 INFOOUTPUT-ALARM-4 ref Output alarm 1 2553 INFO
SEVERITY ALARMS For alarm output functionCRITICAL-ALARM If any alarms with severity set to critical, this alarm is
raised. This can be combined in the alarm outputexpression.
2600 NA
MAJOR-ALARM If any alarms with severity set to major, this alarm israised. This can be combined in the alarm outputexpression.
2601 NA
MINOR-ALARM If any alarms with severity set to minor, this alarm israised. This can be combined in the alarm outputexpression.
2602 NA
WARNING-ALARM If any alarms with severity set to warning, this alarm israised. This can be combined in the alarm outputexpression.
2603 NA
PERFORMANCE ALARMS All software generatedG826-THRESHOLD-15MIN-B1 If the current 15 minute period exceeds the set threshold
for B1, this alarm is set(period 1). After a whole period hasexpired without exceeding the alarm threshold(period 2),the alarm will be cleared when the next periodstarts(period 3).
3000 WARNING
G826-THRESHOLD-15MIN-B2 If the current 15 minute period exceeds the set thresholdfor B2, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing. Only for MS termination.
3001 WARNING
G826-THRESHOLD-15MIN-REI If the current 15 minute period exceeds the set thresholdfor REI, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing. Only for MS termination.
3002 WARNING
G826-THRESHOLD-24Hour-B1 If the current 24 hour period exceeds the set threshold forB1, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1for method of clearing.
3003 WARNING
G826-THRESHOLD-24HOUR-B2 If the current 24 hour period exceeds the set threshold forB2, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1for method of clearing. Only for MS termination.
3004 WARNING
G826-THRESHOLD-24HOUR-REI If the current 24 hour period exceeds the set threshold forREI, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing. Only for MS termination.
3005 WARNING
G826-THRESHOLD-MONTH-B1 If the current month period exceeds the set threshold formonth, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing.
3006 WARNING
G826-THRESHOLD-MONTH_B2 If the current month period exceeds the set threshold formonth, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing. Only for MS termination.
3007 WARNING
G826-THRESHOLD-MONTH-REI If the current month period exceeds the set threshold forREI, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1for method of clearing. Only for MS termination.
3008 WARNING
TRESHOLD-15MIN-OOF If the current 15 minute period exceeds the set thresholdfor OOF, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing.
3015 WARNING
TRESHOLD-24HOUR-OOF If the current 24 hour period exceeds the set threshold forOOF, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing.
3016 WARNING
TRESHOLD-MONTH-OOF If the current month period exceeds the set threshold formonth, this alarm is set. Ref. G826-THRESHOLD-15MIN-B1 for method of clearing.
3017 WARNING
HIGHER ORDER POH ALARMS DescriptionHP-RDI Higher order Path Remote Defect Indicator 5050 WARNINGHP-TIM Higher order Path Trace Identifier Mismatch 5054 MAJOR
374 B4008 Rev. M
CityLink
Fast Ethernet AlarmsAlarm Name Description Id SeverityFTP_USER_LOGGED_IN FTP user logged in 32768 NORMALILLEGAL_DATE_OR_TIME Illegal Date or Time 32770 WARNINGIDU_TEMPERATURE1_HIGH SU Temperature 1 (CPU) exceeded high
limitWARNING32771
IDU_TEMPERATURE2_HIGH SU Temperature 2 (DC/DC) exceeded high limit 32772 WARNINGFAN1_MANUAL_STOP SU Fan 1 is set in manual stop 32773 WARNINGFAN2_MANUAL_STOP SU Fan 2 is set in manual stop 32774 WARNINGFAN1_NOT_RUNNING SU Fan 1 is not running 32775 MAJORFAN2_NOT_RUNNING SU Fan 2 is not running 32776 MAJORI2C_BUS_FAILURE SU internal problem at I2C bus 32777 WARNINGBASEBAND_DEVICE_INIT_FAILURE There was a hardware error in the baseband module
during startup of the IDU32778 MAJOR
MODEM_DEVICE_INIT_FAILURE There was a hardware error in the modem moduleduring startup of the IDU
32779 MAJOR
EEB_DEVICE_INIT_FAILURE There was a hardware error in the ethernet extensionboard module during startup of the IDU
32780 MAJOR
COMMAND_LINE_INIT_FAILURE There was a hardware error in the command lineinterface module during startup of the IDU
32781 WARNING
CONSOLE_USER_LOGGED_IN A user is currently using the command-line interfaceshell on the IDU via the LCT port
32782 NORMAL
TELNET_USER_LOGGED_IN A user is currently using the command-line interfaceshell on the IDU via the telnet
32783 NORMAL
ETHERNET_PORT_1 EEB Port 1 link lost. 32784 NORMALETHERNET_PORT_2 EEB Port 2 link lost. 32785 NORMALETHERNET_PORT_3 EEB Port 3 link lost. 32786 NORMALETHERNET_PORT_4 EEB Port 4 link lost. 32787 NORMALLOS_2MBIT_PORT_1 EEB LOS port 1. 32788 NORMALLOS_2MBIT_PORT_2 EEB LOS port 2. 32789 NORMALLOS_2MBIT_PORT_3 EEB LOS port 3. 32790 NORMALLOS_2MBIT_PORT_4 EEB LOS port 4. 32791 NORMALAIS_INPUT_2MBIT_PORT_1 EEB AIS input port 1. 32792 WARNINGAIS_INPUT_2MBIT_PORT_2 EEB AIS input port 2. 32793 WARNINGAIS_INPUT_2MBIT_PORT_3 EEB AIS input port 3. 32794 WARNINGAIS_INPUT_2MBIT_PORT_4 EEB AIS input port 4. 32795 WARNINGAIS_OUTPUT_2MBIT_PORT_1 EEB AIS output port 1. 32796 WARNINGAIS_OUTPUT_2MBIT_PORT_2 EEB AIS output port 2. 32797 WARNINGAIS_OUTPUT_2MBIT_PORT_3 EEB AIS output port 3. 32798 WARNINGAIS_OUTPUT_2MBIT_PORT_4 EEB AIS output port 4. 32799 WARNINGAIS_INSERT_2MBIT_PORT_1_RX EEB AIS insert port 1 input. 32800 WARNINGAIS_INSERT_2MBIT_PORT_2_RX EEB AIS insert port 2 input. 32801 WARNINGAIS_INSERT_2MBIT_PORT_3_RX EEB AIS insert port 3 input. 32802 WARNINGAIS_INSERT_2MBIT_PORT_4_RX EEB AIS insert port 4 input. 32803 WARNINGLOC_RT Loss of clock in the RT module of the baseband unit
(SORP)32804 CRITICAL
LOC_RR Loss of clock in the RR module of the baseband unit(SORP)
32805 CRITICAL
LOC_LT Loss of clock in the LT module of the baseband unit(SORP)
32806 CRITICAL
LOC_LR Loss of clock in the LR module of the baseband unit(SORP)
32807 CRITICAL
LOS_RR Loss of signal on radio receive (RR) 32808 MAJORLOF_RR Loss of frame on radio receive (RR) 32809 MAJORMS-AIS_RR Alarm indication signal detected on radio receive (RR) 32810 WARNINGMS-AIS_INSERT_RR Alarm indication signal is inserted on radio receive (RR) 32811 MAJORMS-RDI_RR Remote defect indicator detected on radio receive (RR) 32812 WARNINGLOS_LR Loss of signal on line receive (LR): - optical or electrical
CMI.32813 MAJOR
LOF_LR Loss of frame on line receive (LR) 32814 MAJORMS-AIS_LR Alarm indication signal detected on line receive (LR) 32815 WARNINGMS-AIS_INSERT_LR Alarm indication signal is inserted on line receive (LR) 32816 WARNINGMS-RDI_LR Remote defect indicator detected on line receive (LR) 32817 WARNINGMS-AIS_INSERT_RT Alarm indication signal is inserted on radio transmit
(RT)32818 MAJOR
MS-AIS_INSERT_LT Alarm indication signal is inserted on line transmit (LT) 32819 MAJORRS-TRACE-MISMATCH_RR Mismatch between configured string and received string
(RR)32820 MAJOR
RS-TRACE-MISMATCH_LR Mismatch between configured string and received string(LR)
32821 MAJOR
LOOP_MAIN Main traffic looping is active 32822 WARNINGLOOP_WAYSIDE Wayside channel looping is active 32823 WARNINGLOOP_64K 64 kb/s channel looping is active 32824 WARNINGSW_UPDATE_IN_PROGRESS A software update is in progress 32825 WARNINGFREQUENCY_SHIFT A frequency shift is in progress 32826 WARNING
B4008 Rev. M 375
Appendices
Alarm Name Description Id SeverityBELOW_11V_ODU Voltage from the DC-DC converter below limit 32827 WARNINGBELOW_3.3V_ODU Voltage from the DC-DC converter below limit 32828 WARNINGBELOW_48V_ODU Voltage from the DC-DC converter below limit 32829BELOW_-15V_ODU Voltage from the DC-DC converter below limit 32830 WARNINGBELOW_15V_ODU Voltage from the DC-DC converter below limit 32831 WARNINGBELOW_5V_ODU Voltage from the DC-DC converter below limit 32832 WARNINGFAN_ODU 32833 WARNINGFAN2_ODU 32834 WARNINGRX-LO 32835 MAJORTX-LO 32836 MAJORRX-LO-TUNING-WARNING 32837 WARNINGTX-LO-TUNING-WARNING 32838 WARNINGNEED-RX-DRO-TUNING 32839 WARNINGNEED-TX-DRO-TUNING 32840 WARNINGIDU-RESTARTED IDU has been Restarted 32841 INFONETWORK-INTERFACE-CHANGED Changed has been made to the network interface 32842 INFOTRIBUTARY ALARMSAIS-1 Alarm Indication Signal detected in VC-12 #1. 4200 WARNINGAIS-2 Ref: AIS-1 4201 WARNING
M M M MAIS-84 Ref: AIS-1 4283 WARNINGSIGNAL-LABEL-MISMATCH-1 Signal Label Mismatch detected on VC-12 #1. Is set
when the signal label in the LO-POH is set to un-equipped.
4284
SIGNAL-LABEL-MISMATCH-2 Ref: SIGNAL-LABEL-MISMATCH-1 4285 WARNING
M M M MSIGNAL-LABEL-MISMATCH-84 Ref: SIGNAL-LABEL-MISMATCH-1 4367 WARNINGLOS-1 Loss Of Signal in VC-12 #1. 4368 MAJORLOS-2 Ref: LOS-1 4369 MAJOR
M M M MLOS-84 Ref: LOS-1 4451 MAJORLP-RDI-1 Low order Path Remote Defect Indication in VC-12 #1. 4452 WARNINGLP-RDI-2 Ref: LP-RDI-1 4453 WARNING
M M M MLP-RDI-84 Ref: LP-RDI-1 4535 WARNINGLP-RFI-1 Low order Path Remote Failure Indication in VC-12 #1. 4536 WARNINGLP-RFI-2 Ref: LP-RFI-1 4537 WARNING
M M M MLP-RFI-84 Ref: LP-RFI-1 4619 WARNING