See us online: UK- www.killeshalprecast.co.uk | RoI- www.killeshal.com
kilform
Specials made to order
civil product range
JUNCTION BOXES• ESB• CCTV• Eircom
• Services• Lighting• Risers
DUCT CHANNELS AND COVERS• Gas Line Cover Slabs• ESB• Railways
• Headwalls
ROAD GULLY AND LIDS• Untrapped Gully• Trapped Gully• Large Trapped Gully
• Gully Risers• Cast Iron Free Flow Lids
MARKER POSTS, SLABS AND PLATES• Round Top Marker Post• Flat Top Marker Post• Square Head Marker Post• Electrical Marker Post
• Duct Marker Post• Duct Marker Blocks• Hydrant and Water Plates• Earth Rod Box
MISCELLANEOUS• Retaining Wall Blocks• Lamp Post Base
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
fast delivery on ex-stock items to any postcode nationwide
Tel: 080 0393367 Email: sales@killeshalprecast.co.uk
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
JUN
CT
ION
BO
XE
S
REFERENCE SIZE MM A x B x C HOLES 4 WAY HOLES 3 WAY HOLES 2 WAYHOLES
KNOCK OUTWEIGHT
KG
J/B 3 640 x 1110 x 800 • 535
J/B 4 640 x 1110 x 800 • 646
J/B 5 960 x 1270 x 895 • 1066
J/B 9 440 x 590 x 400 • 90
J/B 10 440 x 590 x 400 • 45
J/B 11 420 x 540 x 220 • 46
J/B 12 850 x 850 x 950 • 826
J/B 15 890 x 1450 x 950 • 1215
J/B 18 1150 x 1150 x 850 • 1046
J/B 21 1150 x 1450 x 850 • 1200
J/B 24 450 x 700 x 650 • 328
J/B 25 1000 x 1600 x 1040 • 1515
J/B 26 1290 x 1310 x 1150 • 1600
J/B 27 1190 x 1210 x 870 • 1113
J/B 28 740 x 1210 x 900 • 758
J/B 29 740 x 1210 x 900 • 851
J/B 30 1075 x 1150 x 1050 • 1155
J/B 31 875 x 950 x 900 • 795
J/B 33 800 x 1400 x 895 • 870
J/B 34 1090 x 1110 x 1000 • 1088
J/B 35 1075 x 1150 x 1050 • 838
PAGE
2
JUNCTION BOXES
Technical Queries: UK Tel. 0800 0393367 | RoI Tel. 057 9353018
STANDARDS NOTICE: Killeshal Precast Services Boxes are manufactured to comply withEN1917:2004 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced.
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
JUN
CT
ION
BO
XE
S
PAGE
3
COLOUR CODE BURIED PLASTIC PIPING I.S. 370: 2007Electricity ducting
Public lightingStreet furniture / signal below 125 Volt
Gas pipeBuried potable water
SewerStorm and road drain smooth external wall duct
Storm and road drain corrugatedTelecom / fibre optic smooth external wall duct
Telecom / fibre optic corrugated dUd only-Maximum pipe outside diameter 175 mm
Any colourexcept
Red or Yellow
• Reinforced walls.• eircom approved.• Easily knockout polystyrene cable entry
point/can be supplied with 12/no x 150mmdia straight through entry points (4/no or1. no side wall, 4/no on each cable end).
• Easily manoeuvred with lifting eyes.
Ref: eircom J/B 3
eircom JUNCTION BOX 28 eircom JUNCTION BOX 29• 740 x 1210 x 900mm • 740 x 1210 x 900mm
Ref: eircom J/B 4
Other sizes available contact Killeshal’s customer service on UK: 0800 0393367Irl / Intl.: +353 57 9353 018
Ref: eircom J/B 28 Ref: eircom J/B 29
eircom JUNCTION BOX 3 eircom JUNCTION BOX 4• 640 x 1110 x 800mm • 640 x 1110 x 800mm
Junction Boxes Section***Colour may very depend on application
See more: UK- www.killeshalprecast.co.uk | RoI- www.killeshal.com
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
STANDARDS NOTICE:Killeshal Precast Services Boxes are manufactured to comply with EN1917:2002 / AC:2008 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced.
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
4
JUN
CT
ION
BO
XE
S
JUNCTION BOX 12
JUNCTION BOX 15 JUNCTION BOX 18 JUNCTION BOX 21
• MANHOLE BOX 850 x 850 x 950mm
• MANHOLE BOX890 x 1490 x 950mm
• MANHOLE BOX1150 x 1150 x 850mm
• MANHOLE BOX1150 x 1450 x 850mm
Ref: J/B 12
Ref: J/B 15 Ref: J/B 18 Ref: J/B 21
Base Ref: J/B 23
Frame Ref: J/B 22
Frame Ref: J/B 19
Base Ref: J/B 20
Frame Ref: J/B 16
Base Ref: J/B 17
Frame Ref: J/B 13
Base Ref: J/B 14
ESB MINI PILLAR JUNCTION BOX 5• 960 x 1270 x 895mm
Ref: J/B 5***
• Reinforced walls.• 100 mm shoulder to facilitate
increasing the depth.• Drainage Sump.• Easily manoeuvred.• Multiple cable entry points.• Integrated, reinforced base.
Ref: J/B 24***
***Colour may very depend on application see page 2
See us online: UK- www.killeshalprecast.co.uk | RoI- www.killeshal.com
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
• 450 x 700 x 650mm
JUNCTION BOX 24
MANHOLE BOXES from KILLESHAL Precast Concrete LtdContact us or more information at:Irl / Intl.: +353 57 9353 018 UK Freephone: 0800 039 3367
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
5
JUN
CT
ION
BO
XE
S
TABLE FOR J/B 25, J/B 26, J/B 27
BLINDING AND EMBEDDING REQUIREMENTS IN ACCORDANCE WITH HD 25/95
SUBGRAGE DBR%
SUB-BASE THICKNESSMM
EDGE DISTANCE FROM BOXTO EDGE BLINDING MM
SUB-BASE MATERIAL
>5 225 225 GRANULAR MATERIAL (TYPE2)
5<CBR<3 300 300 GRANULAR MATERIAL (TYPE2)
3<CBR<2 350 300 GRANULAR MATERIAL (TYPE2)
<2 600-1000 300
600MM OF CAPPING (6F1 OR 6F2) OVERLAID BY A
GRANULAR SUB-BASE (TYPE2)UP TO 400MM IF REQUIRED
JUNCTION BOX 25• 1000 x 1600 x 1040mm
Ref: J/B 25***
• Reinforced concrete walls.• Preformed cable entry
points.• Integrated reinforced base.• Base incorporating sump.• Easily manoeuvred with
lifting hooks.• Ironmongery fitted.
NRA RCD/500/54 JUNCTION BOX 26• 1290 x 1310 x 1150mm
• Reinforced concrete walls.• Preformed cable entry points.• Integrated reinforced base.• Splayed base to aid stability.• Easily manoeuvred.• Base incorporating sump.
Ref: J/B 26***
JUNCTION BOX 27• 1190 x 1210 x 870mm
Ref: J/B 27***
***Colour may very depend on application see page 2
For J/B 25 without base see J/B 33
For J/B 26 without base see J/B 34
For J/B 27 without base see J/B 35
High adjusting riser to suit see J/B 502
High adjusting riser to suit see J/B 502
Technical Queries: UK Tel. 0800 0393367 | RoI Tel. 057 9353018
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
JUN
CT
ION
BO
XE
S
PAGE
6
JUNCTION BOX 31 JUNCTION BOX 30• 875 x 950 x 900mm • 1075 x 1150 x 1050mm
Ref: J/B 501
Ref: J/B 30***
JUNCTION BOX RISER J/B 501 JUNCTION BOX RISER J/B 502• 875 x 950 x 150mm
To suit: - J/B 31 - J/B 30
• 1090 x 1110 x 100mmTo suit: - J/B 26 - J/B 27 - J/B 34 - J/B 35
Ref: J/B 31***
JUNCTION BOX 33• 800 x 1400 x 895mm
Ref: J/B 33***
Ref: J/B 34***
Ref: J/B 35***
Ref: J/B 502***Colour may very depend on application see page 2
For J/B 30 withoutbase see J/B 31
High adjusting riserto suit see J/B 501
For J/B 31 withbase see J/B 30
High adjusting riserto suit see J/B 501
JUNCTION BOX 35• 1075 x 1150 x 1050mm
For J/B 35 with base see J/B 27
High adjusting riser to suit see J/B 502
JUNCTION BOX 34• 1090 x 1110 x 1000mm
For J/B 34 with base see J/B 26
High adjusting riser to suit see J/B 502
For J/B 33 with base see J/B 25
High adjusting riser to suit see J/B 502
Riser if requiredfor high adjustment
Riser if requiredfor high adjustment
Customer Service: UK Tel. 0800 0393367 | RoI Tel. 057 9353018
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
7
DU
CT
CH
AN
NE
LS
AN
D C
OV
ER
S
SPILLWAY CHANNEL 116
HEADWALLS
• 343 to 450 x 710 x 895 x 1000mm
• 1820 x 1037 x 2000mm
DUCT CHANNEL 117•
DUCT CHANNEL 114 DUCT CHANNEL 115
• 170 x 440 x 1000mm • 170 x 280 x 1000mm
Ref: D/CH 115Ref: D/CH 114
Ref: D/C 228
GAS LINE COVER SLABS
• 1450 x 100mm • 1450 x 150mm • 1450 x 200mm
Ref: D/C 199Ref: D/C 242
Ref: D/CH 116Ref: M/127
Other sizes availablecontact Killeshal’scustomer service on 0800 0393367
DUCT COVERRef: D/C 260
DUCT COVERRef: D/C 262
See us online: UK- www.killeshalprecast.co.uk | RoI- www.killeshal.com
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
340 x 448 x 1000mm
Ref: D/CH 117
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
8
UNTRAPPED GULLY• UNTRAPPED GULLY (800x380x445mm)
Ref: G/1Ref: G/1 + G/R 104 + C/250 (G/9)Ref: G/1 + G/R 104
TRAPPED GULLY• TRAPPED GULLY (800x500x375mm)
Ref: G/2 Ref: G/2 + G/R 104Ref: G/2 + G/R 104 + C/250 (G/9)
LARGE TRAPPED GULLY• LARGE TRAPPED GULLY (805x585x450mm)
Ref: G/5 G/R 103 + C/250 (G/9)Ref: G/5 + Ref: G/5 +
G/R 102 + C/400 (G/10)
RO
AD
GU
LLY
AN
D L
IDS
GULLY RISERS• 970x970x85mm • 750x650x100mm
To suit:- G/5
• 750x650x100mmTo suit:- G/5
• 610x610x100mmTo suit:- G/1- G/2
CAST IRON FREE FLOW LIDS• 527x527x100mm
To suit:- G/5
• 515x395x75mmTo suit:- G/1- G/2- G/5
Ref: G/R 102 Ref: G/R 104Ref: G/R 103 Ref: D/400 (G/10) Ref: D/250 (G/9)Ref: G/R 101
See us online: UK- www.killeshalprecast.co.uk | RoI- www.killeshal.com
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
PAGE
9
MARKER POSTS AND SLABS• marker posts are placed at or behind location points for services such as
AV/SV, hydrant chambers, water and gas chambers, electric cable junctions andfield markers as markers for emergency services or service engineers
• buried hazard warning marker slabs which shadow electricity lines andgas pipes, helping to avoid breaches and health and safety incidents
For Line Drainage See Pre-Fabricated Drainage System Catalogue
PLATES• HYDRANT PLATES • WATER PLATES
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
MA
RK
ER
PO
ST
S &
PLA
TE
S
Ref: M/POST 113 Ref: M/POST 114 Ref: M/POST 115
RETAINING WALL BLOCKS LAMP POST BASE• 1400 x 695 x 795mm • 700 x 700 x 700mm
Ref: M/112
Ref: IR/11
MIS
CE
LLA
NE
OU
S
• DUCT MARKER BLOCK(300x300x225mm)
• DUCT MARKER BLOCK(300x300x225mm)
• DUCT MARKER BLOCK(300x300x225mm)
• EARTH ROD BOX(325x325x150mm)
*Made to suit each individual requirements *Full range of plates available
• ROUND TOP(300x100x1090mm)*Plates see below
• FLAT TOP(270x80x1220mm)*Plates see below
• SQUARE HEAD(75x100x1230mm)*Plates see below
• DUCT(110x140x1600mm)
Ref: M/POST 101 Ref: M/POST 102 Ref: M/POST 111Ref: M/POST 116
See us online: UK- www.killeshalprecast.co.uk | RoI- www.killeshal.com
UK Tel: 0800 0393367 - Rep. Irl Tel: 057 9353018
Ref: M/123
Technical Queries: UK Tel. 0800 0393367 | RoI Tel. 057 9353018
R . I OFFICETel: +353 (0)57 9353018
Email: sales@killeshal.comWeb: killeshal.com
UK OFFICETel: 0800 0393367
Email: sales@killeshalprecast.co.ukWeb: killeshalprecast.co.uk
top related