contrator orbit – rlr · the orbit rlr series is our led recessed multi-spot. ... item number nbr...
Post on 08-Jul-2018
217 Views
Preview:
TRANSCRIPT
2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com
DESCRIPTION
The Orbit RLR series is our LED recessed multi-spot. Whether you’re designing a completely new commercial venue or planning a renovation, the Orbit RLR offers the flexibility for either of those options with the same housing. This is the ideal fixture for commercial office, residential, retail, restaurant and hotel lighting projects that require the beauty of recessed lighting.
SPECIFICATIONS
Non-IC new construction or existant ceiling
Material: Diecast aluminum Optical compartment and metal backboxInstallation: Integral wire connection box Integral transformer for T-bar & drywall ceiling availableAdjustable: Universal joint for independent adjustment of each gimbal
head, horizontal 356°, vertical 56°
LAMP/DRIVER
Per lamp* S1 LED 23W 2200lm at 3000K, 80+ CRI or 1800lm at 3000K, 90+ CRI
S2 LED 33W 3000lm at 3000K, 80+ CRI or 2400lm at 3000K, 90+ CRI
S3 LED 45W 4300lm at 3000K, 80+ CRI or 3600lm at 3000K, 90+ CRI
S4 LED 52W 5000lm at 3000K, 80+ CRI or 4100lm at 3000K, 90+ CRI
Driver Integral electronic, dimmable with 0-10VDC dimmers Estimated lifespan of over 50,000 hours to L70
* Lumens are based on 36° flood beam angle.DIMMER LISTLutron Diva® DVTV
Diva® DVSCTVDiva® DVSTVDiva® DVSCSTVNova® NFTV
Leviton IllumaTech IP7 seriesPhilips Sunrise-SRI200ZTUNV
The fixture dimmer compatibility table shown above is for dimming functionality only. The dimmers listed in this chart may not comply to ICES 005 class A or B standards. To confirm ICES 005 compliance please contact the dimmer manufacturer.
REFLECTOR POSITIONINg guIDE
One individual reflector per gimbal. Please specify in the ordering guide.
** The first reflector is always positioned next to the junction box.
1** 32
1** 32 4
1** 1** 2
ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe
005ICES
Approvals: CSA Certified to C22.2 #250, UL1598ICES 005
yr
warranty
Project:
Contractor:
2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com
RLR L
Serieslamp configuration
lamp type
lumen package delivered(per lamp)***
CRI Voltage****Housingcolour
Trim colour
Gimbal colour
Colour temperature
Reflectors (one per gimbal)Option
1 2 3 4
RLR 1 - 1 lamp2 - 2 lamps3 - 3 lamps4 - 4 lamps
L - led S1 - 2200 lm (23W)
S2 - 3000 lm (33W)
S3 - 4300 lm (45W)
S4 - 5000 lm (52W)
80 - 80+ CRI90 - 90+ CRI
A - 120VH - 347V
B - blackW***** - White
B - blackS - SilverW - White
B - blackS - SilverW - White
27K - 2700K30K - 3000K35K****** - 3500K40K - 4000K
S - SpotM - med.F - Flood
S - SpotM - med.F - Flood
S - SpotM - med.F - Flood
S - SpotM - med.F - Flood
DIM1 - 0-10V dC dimming driver
*** Please see lumen table for detailed CRI. Approximate delivered lumens. **** For other voltages, please consult factory. ***** Use with white gimbal only. ****** 3500K, 80+ CRI.
ORDERINg guIDE
OPTIONAL PLASTER FRAME Order separately
Item number Nbr of lamps dim. A dim. b dim. C dim. dPF-Rg/RF-1 1 lamp 7.28" 7.4" 8.27" 10.30"PF-Rg/RF-2 2 lamps 7.28" 14.76" 15.75" 10.30"PF-Rg/RF-3 3 lamps 7.28" 21.26" 22.25" 10.30"PF-Rg/RF-4 4 lamps 7.28" 27.76" 28.74" 10.30"
LuMEN CRI TABLE80 90
S1 2200 lm 1800 lmS2 3000 lm 2400 lmS3 4300 lm 3600 lmS4 5000 lm 4100 lm
Note: Lumen information is based on 36° flood beam reflector and 3000K colour temperature. Please refer to IES files for more information.
Dimension C
Dim
ensi
on D
Dimension C
Dim
ensi
on D
Ceiling opening(dimensions A & b)
1.18"
Dimension B
Dim
ensi
on A
0.5"
DIMENSIONS
ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe
005ICES
Approvals: CSA Certified to C22.2 #250, UL1598ICES 005
yr
warranty
Project:
Contractor:
2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com
PHOTOMETRY – 4895.1 LM / 80 CRI
PHOTOMETRY – 5303.9 LM / 80 CRI
PHOTOMETRY – 5026.7 LM / 80 CRI
PHOTOMETRY – 4183.8 LM / 90 CRI
RLR-1LS480-A/30K/FInput wattage: 52Total luminaire lumens: 4895.1lumens per watt: 94.14beam angle: Flood 36°
RLR-1LS480-A/30K/SInput wattage: 52Total luminaire lumens: 5303.9lumens per watt: 102beam angle: Spot 23°
RLR-1LS480-A/30K/MInput wattage: 52Total luminaire lumens: 5026.7lumens per watt: 96.67beam angle: Medium 27°
RLR-1LS490-A/30K/FInput wattage: 52Total luminaire lumens: 4183.8lumens per watt: 80.65beam angle: Flood 35.7°
Filename: RLR-1-LS4-80-30K-FManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4895.1
Max Candela: 10,764.0 at Horizontal: 0°, Vertical: 0°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702172-R1 config from
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 5 X 5
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 4,058.5 82.9%
0-40 4,815.7 98.4%
0-60 4,895.1 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,895.1 100%
90-180 0 0%
0-180 4,895.1 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 941.2 19.2% 90-100 0 0%
10-20 1,830.9 37.4% 100-110 0 0%
20-30 1,286.5 26.3% 110-120 0 0%
30-40 757.1 15.5% 120-130 0 0%
40-50 79.4 1.6% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .95
50 30 20
1.11 1.11 1.11
1.06 1.04 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.95
Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-F
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-F_rep.htm
Filename: RLR-1-LS4-80-30K-MManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 5026.7
Max Candela: 15,846.5 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702171-R1 config from
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 4,224.3 84%
0-40 4,950.6 98.5%
0-60 5,026.7 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 5,026.7 100%
90-180 0 0%
0-180 5,026.7 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,305.2 26.0% 90-100 0 0%
10-20 1,840.7 36.6% 100-110 0 0%
20-30 1,078.3 21.5% 110-120 0 0%
30-40 726.3 14.4% 120-130 0 0%
40-50 76.2 1.5% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-M
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-M_rep.htm
Filename: RLR-1-LS4-80-30K-FManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4895.1
Max Candela: 10,764.0 at Horizontal: 0°, Vertical: 0°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702172-R1 config from
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 5 X 5
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 4,058.5 82.9%
0-40 4,815.7 98.4%
0-60 4,895.1 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,895.1 100%
90-180 0 0%
0-180 4,895.1 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 941.2 19.2% 90-100 0 0%
10-20 1,830.9 37.4% 100-110 0 0%
20-30 1,286.5 26.3% 110-120 0 0%
30-40 757.1 15.5% 120-130 0 0%
40-50 79.4 1.6% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .95
50 30 20
1.11 1.11 1.11
1.06 1.04 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.95
Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-F
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-F_rep.htm
Filename: RLR-1-LS4-80-30K-MManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 5026.7
Max Candela: 15,846.5 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702171-R1 config from
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 4,224.3 84%
0-40 4,950.6 98.5%
0-60 5,026.7 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 5,026.7 100%
90-180 0 0%
0-180 5,026.7 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,305.2 26.0% 90-100 0 0%
10-20 1,840.7 36.6% 100-110 0 0%
20-30 1,078.3 21.5% 110-120 0 0%
30-40 726.3 14.4% 120-130 0 0%
40-50 76.2 1.5% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-M
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-M_rep.htm
Zonal lumen summaryZone lumens % Fixture
0-30 4058.5 82.9%0-40 4815.7 98.4%0-60 4895.1 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4895.1 100%90-180 0 0%0-180 4895.1 100%
Zonal lumen summaryZone lumens % Fixture
0-30 4366.8 82.3%0-40 5188.1 97.8%0-60 5303.9 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 5303.9 100%90-180 0 0%0-180 5303.9 100%
Zonal lumen summaryZone lumens % Fixture
0-30 4224.3 84%0-40 4950.6 98.5%0-60 5026.7 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 5026.7 100%90-180 0 0%0-180 5026.7 100%
Zonal lumen summaryZone lumens % Fixture
0-30 3468.8 82.9%0-40 4115.9 98.4%0-60 4183.8 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4183.8 100%90-180 0 0%0-180 4183.8 100%
ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe
Filename: RLR-1-LS4-80-30K-SManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 5303.9
Max Candela: 20,955.9 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702205-R1 config from
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 4,366.8 82.3%
0-40 5,188.1 97.8%
0-60 5,303.9 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 5,303.9 100%
90-180 0 0%
0-180 5,303.9 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,682.5 31.7% 90-100 0 0%
10-20 1,692.2 31.9% 100-110 0 0%
20-30 992.2 18.7% 110-120 0 0%
30-40 821.3 15.5% 120-130 0 0%
40-50 115.8 2.2% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.15 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-S
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-S_rep.htm
Filename: RLR-1-LS4-80-30K-SManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 5303.9
Max Candela: 20,955.9 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702205-R1 config from
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 4,366.8 82.3%
0-40 5,188.1 97.8%
0-60 5,303.9 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 5,303.9 100%
90-180 0 0%
0-180 5,303.9 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,682.5 31.7% 90-100 0 0%
10-20 1,692.2 31.9% 100-110 0 0%
20-30 992.2 18.7% 110-120 0 0%
30-40 821.3 15.5% 120-130 0 0%
40-50 115.8 2.2% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.15 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-S
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-S_rep.htm
Filename: RLR-1-LS4-90-30K-FManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4183.8
Max Candela: 9,200.0 at Horizontal: 0°, Vertical: 0°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702172-R1
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 5 X 5
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 3,468.8 82.9%
0-40 4,115.9 98.4%
0-60 4,183.8 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,183.8 100%
90-180 0 0%
0-180 4,183.8 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 804.4 19.2% 90-100 0 0%
10-20 1,564.9 37.4% 100-110 0 0%
20-30 1,099.5 26.3% 110-120 0 0%
30-40 647.1 15.5% 120-130 0 0%
40-50 67.9 1.6% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .95
50 30 20
1.11 1.11 1.11
1.06 1.04 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.95
Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-F
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-F_rep.htm
Filename: RLR-1-LS4-90-30K-FManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4183.8
Max Candela: 9,200.0 at Horizontal: 0°, Vertical: 0°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702172-R1
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 5 X 5
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 3,468.8 82.9%
0-40 4,115.9 98.4%
0-60 4,183.8 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,183.8 100%
90-180 0 0%
0-180 4,183.8 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 804.4 19.2% 90-100 0 0%
10-20 1,564.9 37.4% 100-110 0 0%
20-30 1,099.5 26.3% 110-120 0 0%
30-40 647.1 15.5% 120-130 0 0%
40-50 67.9 1.6% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .95
50 30 20
1.11 1.11 1.11
1.06 1.04 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.95
Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-F
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-F_rep.htm
Project:
Contractor:
2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com
PHOTOMETRY – 4296.4 LM / 90 CRI PHOTOMETRY – 4533.2 LM / 90 CRI
RLR-1LS490-A/30K/MInput wattage: 52Total luminaire lumens: 4296.4lumens per watt: 82.62beam angle: Medium 27°
RLR-1LS490-A/30K/SInput wattage: 52Total luminaire lumens: 4533.2lumens per watt: 87.18beam angle: Spot 23°
Zonal lumen summaryZone lumens % Fixture
0-30 3610.5 84%0-40 4231.3 98.5%0-60 4296.4 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4296.4 100%90-180 0 0%0-180 4296.4 100%
Zonal lumen summaryZone lumens % Fixture
0-30 3732.3 82.3%0-40 4434.3 97.8%0-60 4533.2 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4533.2 100%90-180 0 0%0-180 4533.2 100%
ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe
Filename: RLR-1-LS4-90-30K-MManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4296.4
Max Candela: 13,544.0 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702171-R1
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 3,610.5 84%
0-40 4,231.3 98.5%
0-60 4,296.4 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,296.4 100%
90-180 0 0%
0-180 4,296.4 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,115.6 26.0% 90-100 0 0%
10-20 1,573.2 36.6% 100-110 0 0%
20-30 921.7 21.5% 110-120 0 0%
30-40 620.8 14.4% 120-130 0 0%
40-50 65.1 1.5% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-M
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-M_rep.htm
Filename: RLR-1-LS4-90-30K-MManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4296.4
Max Candela: 13,544.0 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702171-R1
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 3,610.5 84%
0-40 4,231.3 98.5%
0-60 4,296.4 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,296.4 100%
90-180 0 0%
0-180 4,296.4 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,115.6 26.0% 90-100 0 0%
10-20 1,573.2 36.6% 100-110 0 0%
20-30 921.7 21.5% 110-120 0 0%
30-40 620.8 14.4% 120-130 0 0%
40-50 65.1 1.5% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.14 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-M
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-M_rep.htm
Filename: RLR-1-LS4-90-30K-SManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4533.2
Max Candela: 17,911.0 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702205-R1
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 3,732.3 82.3%
0-40 4,434.3 97.8%
0-60 4,533.2 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,533.2 100%
90-180 0 0%
0-180 4,533.2 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,438.0 31.7% 90-100 0 0%
10-20 1,446.3 31.9% 100-110 0 0%
20-30 848.0 18.7% 110-120 0 0%
30-40 701.9 15.5% 120-130 0 0%
40-50 99.0 2.2% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.15 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-S
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-S_rep.htm
Filename: RLR-1-LS4-90-30K-SManufacturer: Stanpro
Luminaire: RLR-L
Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S
Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V
Distribution: Direct Type - Downlight
Lamp Output: Total luminaire Lumens: 4533.2
Max Candela: 17,911.0 at Horizontal: 0°, Vertical: 1°
Input Wattage: 52
Luminous Opening: Circular (Dia: 2.75")
Test: S1702205-R1
Test Lab: Spectra Lux Industries Inc.
Photometry : Type C
CIE Class: Direct
Cutoff Class: Full Cutoff
Nema Type: 4 X 4
Zonal Lumen SummaryZone Lumens % Luminaire
0-30 3,732.3 82.3%
0-40 4,434.3 97.8%
0-60 4,533.2 100%
60-90 0 0%
70-100 0 0%
90-120 0 0%
0-90 4,533.2 100%
90-180 0 0%
0-180 4,533.2 100%
Lumens Per ZoneZone Lumens % Total Zone Lumens % Total
0-10 1,438.0 31.7% 90-100 0 0%
10-20 1,446.3 31.9% 100-110 0 0%
20-30 848.0 18.7% 110-120 0 0%
30-40 701.9 15.5% 120-130 0 0%
40-50 99.0 2.2% 130-140 0 0%
50-60 0 0.0% 140-150 0 0%
60-70 0 0.0% 150-160 0 0%
70-80 0 0.0% 160-170 0 0%
80-90 0 0.0% 170-180 0 0%
Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%
RCC %: 80 70 50 30 10 0
RW %:
RCR: 0
1
70 50 30 0
1.19 1.19 1.19 1.19
1.15 1.12 1.10 1.08
70 50 30 0
1.16 1.16 1.16 1.00
1.12 1.10 1.08 .96
50 30 20
1.11 1.11 1.11
1.06 1.05 1.03
50 30 20
1.06 1.06 1.06
1.02 1.01 1.00
50 30 20
1.02 1.02 1.02
.99 .98 .97
0
1.00
.96
Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-S
1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-S_rep.htm
Project: