Midea Is Your Idea
2007
GD Midea Commercial Air-conditioning Equipment Co., Ltd.
Add: Midea Industrial City, Shunde, Foshan, Guangdong, 528311, P.R.China
Tel: +86-757-26339642 Fax: +86-757-26339337
E-mail: mcac@midea.com.cn
Http: //www.midea.com.cn
Http: //www.mdvchina.com (customer service)
Midea Air ConditionersChiller System
1 2
N433
E U ROV EN TCERTIFIED PERFORMANCE
TUV Rheiniand Group Production inspected
L I S T E D
TUV Rheiniand
gepruftesicherheit
NRTL/CISO 14001: 1996
Certificate No.:CC1417
068
CERTIFIEDCOMPANYCERTIFIED
COMPANY
ISO 9001 : 2000Certificate No.: CC 454
068
I NTERN AT IONAL CONFORMI TY C ERT I F ICAT I
ONPR
OGRA
MSAUDI ARABIAN STANDARDS ORGANIZAT
I ON
Midea produced its first Air
Conditioner in 1985. Currently
we are the leader of Air
conditioner manufacturing
and export. Midea has been
exporting Air Conditioners for
the last 16 years, and during
this time Midea has cultivated
strong partnerships with
hundreds of overseas
companies.
Midea is dedicated to
continuous improvement. Over
1000 engineers work together
to push the improvement of
AC technology. Every year
over 300 new products are
developed and 100 new
patents are filed. New products
account for 30% of total sales
volume and 35% of gross
profit.
Our vertically integrated
supply chain enables us to
achieve maximum efficiency
in production and product
development.
We p rov ide G loba l
technical training and a
comprehensive online
customer service. All our
customers from over 110
countries and regions
receive top quality service
at all times.
Our goal is to deliver the
highest quality products to
our costumers. Quality is one
of the core competencies of
Midea.
Midea Creates A Better Life
geprufteSicherheit
..
Dry expansion evaporator:
Single-compressor: 40RT~245RT
Dual-compressor: 280RT~490RT
Flooded type evaporator:
Single-compressor: 120RT~255RT
Dual-compressor: 290RT~510RT
R123 single-stage compression: 200RT~800RT
R123 dual-stage compression: 900RT~1200RT
R134a single-stage compression: 350RT~1100RT
R134a dual-stage compression: 1200RT~2000RT
Digital scroll or constant speed scroll: 30~520kW Constant speed scroll:185kW~1480kW
100kW~145kW
2007 Midea Commercial A/C Model Line Up[ L ] Centrifugal Chiller system
[ C ] Water-cooled Screw Chiller system
[ A ] Air-cooled Modular Chiller System
[ W ] Water-Cooled Package Unit
3 4
[ K ] Air Handling Unit & Fan Coil Unit
62-7
1Air Handling Unit
Fan Coil Unit
Single wall
horizontal type
Single
wall vertical type
Dual
wall horizontal type
Dual
wall vertical type
Wall-mounted type
[ S ] Water-Source Heat Pump
54-6
1
5.0-14.0kW
Water source
high static pressure duct
Water source
low static pressure duct
Water source
four way cassette
35kW
[ R ] Heating Water System
49-5
3
35kW17.5kW9kW7kW
45-4
8
5-21
22-3
334
-44
60kW~80kW
Concealed
floor standing
Expoded
floor standing
Duct typeOne way
cassette
Four way
cassette
Four way cassette
(compact)
CentrifugalChiller system[ L ] Series
Centrifugal Chiller system
7 8
Brief introduction of R-134a series
R-134a series hermetic centrifugal chiller system, are developed to replace the current
CFC centrifugal chiller series for the project national scheme of China ozone layer consuming
material gradually falling into disuse. The series take the environmental friendly refrigerant
HFC-134a as refrigerant. On august 1999, the first sample170H-6P centrifugal chilled
system gained the approval as national class new product, professional team's appraisal:
unit's main technical performance is advanced among the same kind of products, with
friendly environmental quality and excellent energy-saving effect, the market prospect is
expansive.
HOW TO READ THE MODELS ?
M H C - A S 650 S / A N3
Midea
Centrifugal Chiller
Compression Quantity:A Single Compressor
D Dual Compressor
Compression-stage:S Single-stage Compression
D Dual-stage Compression
Power Type:A 6000V/50Hz/3PhB 10000V/50Hz/3PhC 380V/50Hz/3Ph
Compressor Type:H HemeticS Semi-hermeticO Opening
Heavy Commercial Chiller System
Refrigerant Type:N3 R134a
N5 R123
- R22
Nominal Cooling Capacity (USRT)
Reliable gearing & long-span operationLess moving parts in compressor and high quality components guarantee a common lifespan over 20 years.The propeller is made of peculiar cast aluminium alloy and proved to be of sufficient mechanical strength and high erosion resistance after high precision dynamic balance test and over-speed test.The keyless connection between propeller and axis avoids the stress concentration and accessional unbalance of rotor. It will improve the reliability considerably. The technology obtained the national patent, the patent serial number is ZL01256825.2.Peculiar design of high precision helical gear counteracts the axial thrust force caused by propeller, reduces the gearing's load and makes the transmission smoothly. Hermetic motor is cooled efficiently by evaporative refrigerant ejecting. Therefore, it ensures unit safety and long lifespan and also can prevent the refrigerant from leakage.
The pneumatic part of compressor is designed through NREC pneumatic software which is one of themost advanced design softwares in the world. Adopts high-efficiency and three-dimension hermetical impeller designed for refrigerant HCFC-123/HFC-134a, avoids performance fluctuation caused by gap change between semi-open impeller and scroll-case.The heat transfer pipes of condenser and evaporator adopt high efficiency heat transfer pipes designed individually according to boil principle and concreting principle, improve gross heat transfer coefficient and as well as be able to realize the heat transfer with small temperature difference.The optimal matching of advanced compressor with new-style & high-efficiency heat exchanger guarantees a high efficiency unit.Special designed guide vane can adjust refrigerant mass flow to fulfil partial load requirement, and by pre-regulating gas entering direction, refrigerant can flow into the propeller in optimal angle and unit efficiency is improved greatly.
Centrifugal Chiller system
Adopt new-type environmental friendly refrigerantR-123 series centrifugal chiller system take HCFC-123 as refrigerant. HCFC-123 is an optimal choice considering ozone depleting, greenhouse effect and energy effect.R-134a series centrifugal chiller system take HCFC-134a as refrigerant. HCFC-134a is the green refrigerant accepted internationally, without destructive effect to ozone, and accords to the standards of international environmental protection pact and national scheme of china consume ozone material gradually falling into disuse.
Features
Advanced technology & high efficiency
Propellor overspeed test on overspeed experiment device of German Schenk
An extra high-efficiency cooler in condenser subcools liquid refrigerant and improves the efficiency.The energy saver between double stage compressors reduces unit power consumption by 5%, so as to increase cooling capacity of refrigerant per mass unit and compressed quantity of refrigerant entering into the first stage reduces, otherwise, refrigerant at intermediate pressure between evaporator and condenser will flash and the refrigerant between stages cooled by flash gas will improves unit*s efficiency. Optimize the pipe arrangement, reduce the refrigerant friction loss, and guarantee excellent operation efficiency.
Reliable lubricating systemThe closed oil pump immersed in oil can send the pressure oil to the surface of each high-speed gear.Plate oil cooler cooled with refrigerant ensures the oil pumped by oil pump to be cooled to a low temperature.Impurity in oil is filtered by high precision papery filter. ensures the dynamic pressure oil film forming on high-speed gearing, and filter core can be replaced conveniently.The high oil box on top of compressor ensures the oil quantity used for gearing when emergent power-off occurs, and avoids the gearing from abrasion.
Wide range of adjustable capacityThe chiller system of medium & large capacity adopts non-
vane pressure enlarger and inlet guard vane, hence enlarge
cooling adjusting range, and the unit's coolingcapacity can
be adjusted optionally from 10% to 100% at a invariable
cooling water inlet temperature.
Inlet guide vane
9 10
Centrifugal Chiller system
Low noise & stable runningAll the gears are rectified in height and width in order to reduce the mesh noise.The double-layer noise proof structure of gear box minimizes the noise level.Flux passage with optimized design reduces the noise level and refrigerant flow speed. Noise-proof device fixed on the inlet of condenser can reduce the refrigerant flow impact noise. The special design of compressor assembled with hermetic motor cooling by refrigerant saves the connecting and hermetic device between motor and compressor which is necessary for unclosed motor, and reduces damageable process, as well as reduces the motor outline dimension and motor noise.The unit's mean-time to failure can be more than five years.
Reliable performance testReliable performance testThe assemblage of propeller with gear is tested in dynamic balance experiment with an over-speed which is 120% of the rated.Heat exchanger and power saver are strictly tested by pressure experiment according the national norm JB4750 defined by pressure container for refriferation quipment. Must carry out gas seal test and vacuum test after whole unit is assembled.The performance test is operated on special experiment table according to national standard, strictly tested each norm, and can't leave factory until it fulfil the design demand. balance test on Schenck Dynamic balancing
machine (Germany)
ApprovalDesign, manufacture and experiment of unit are all according to the national standard GB/T 18430.1-2001 vapor compression cycle Water chilling (heat pump) packages and JB 4750 pressure container for refrigerating device.Our company has obtained ISO 9001 certification, and it is the first to obtain environment product approval in national trade.
Wider applicationBe able to customize special centrifugal compressor with large cooling capacity and dual-compressor according to user's demand, capacity of single unit can reach up to 4000RT.Be able to design high-voltage products of 6000v or 10000v, reduces the impact to electric network, as well as save the transformer, has wider application.Be able to design non-standard products based on actual temperature of water inlet and outlet, so as to achieve the best energy-saving effect, fulfil user's demand.
11 12
Standing-by interface Malfunction display interface Coefficient display interface
Advanced Micro-computer control systemThe special designed micro-computer control system can optimize control logic, improve operation
efficiency, is reliable with long-term running.
Touchpad display makes the operation easy and direct.
Operation data and malfunction alarms can be displayed on the indicator, so to monitor unit instantly.
The micro-computer control system can execute more than 30 control and protection actions and record
the latest 10 error parameters, main control unit adopting advanced import components which have better
disturbance resistance and guarantee the units work safely and reliably.
The built-in RS422 communication port can realize central control. It also can connect with user's PC,
and realizes remote control start, operation and stop.
Adopts the PLC controller of CQM1-Japanese Omilong series to precisely control temperature.
The control system adopts EL highlight touchpad display of GP-477 series produced by Japanese DIGITAL,
and the moving picture will display operation interface, and operates each control by slight touch refer
to wok condition indicator.
In central monitor system, the micro-computer is connected with the CPU modules of multi sets of
centrifugal chiller systems micro-computer control system (PC-LXZ-H) through RS422 port, can control
maximum 32 sets of centrifugal refrigerators and the water pump, cooling tower and other accessories.
Features
Centrifugal Chiller system
R-123 single-stage series (200-400RT)
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
R123 single-stage series (500-800RT)
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
MHC-AS(500-800)H/A(B)(C)N5
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant ejecting
380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
R123 charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unit dimensions
700
700
2461
211.5
423
84
2
DN300
529
107
2
DN300
455
1100
76
14330
14900
5450
1890
2950
800
800
2813
241.9
484
85
2
DN300
604
107
2
DN300
515
1100
76
14700
15500
5450
1890
2950
600
600
2110
181
362
144
3
DN250
452
53
2
DN250
385
920
76
12285
13080
4620
1890
2950
500
500
1755
151
302
141
3
DN250
378
53
2
DN250
320
920
45
11920
12590
4620
1890
2720
MHC-AS(200-400)H/A(B)(C)N5
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant ejecting
380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
200
200
703
60.5
121
136
4
DN150
150
72
3
DN150
150
250
250
879
75.5
151
142
4
DN150
183
76
3
DN150
180
300
300
1055
90.7
181.4
143
4
DN150
226
78
3
DN150
200
350
350
1230
105
212
134
4
DN200
264
50
3
DN200
235
400
400
1406
120
242
143
4
DN200
302
54
3
DN200
260
R123 charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unitdimensions
540
45
8090
8300
3560
1580
2430
540
45
8290
8500
3560
1580
2430
700
45
8490
8700
3560
1580
2430
700
45
9870
8300
4552
1580
2430
700
45
10090
8300
4552
1580
2430
13 14
Centrifugal Chiller system
R-123 dual-stage series (900-1200RT) R134a single-stage series (350-500RT)
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
MHC-AS(350-500)H/A(B)(C)N3
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant ejecting R134a charging volume
380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
R134a charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unit dimensions
450
450
1582
136
272
106
3
DN200
340
83.1
3
DN200
308
550
63
9930
9420
4310
1775
2460
500
500
1758
151
302
106
3
DN200
378
85
3
DN200
350
565
63
10130
9700
4310
1775
2460
400
400
1406
120
242
115
3
DN200
302
81.4
3
DN200
274
450
63
9440
8810
4310
1620
2395
350
350
1230
105
212
114
3
DN200
265
82.2
3
DN200
244
420
63
9210
8510
4310
1620
2395
D
E
F
G
H
J
K
L
Supportmm
mm
mm
mm
mm
mm
mm
mm
3340
1420
510
490
460
790
760
1060
3340
1420
510
490
460
790
760
1060
3340
1575
510
500
510
855
790
1140
3340
1575
510
500
510
855
790
1140
Connect pipesetting
dimensions
15 16
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
MHC-AD(900-1200)H/A(B)(C)N5
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant liquid ejecting-evaporating
380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
R123 charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unit dimensions
1100
1100
3867
332
665
102
2
DN300, PN1.0
818
94
2
DN350, PN1.0
650
1970
71
24300
25850
6285
2190
3522
1200
1200
4220
363
726
102
2
DN300, PN1.0
839
98
2
DN350, PN1.0
710
2150
71
24700
26550
6285
2190
3522
1000
1000
3516
302
605
102
2
DN300, PN1.0
744
94
2
DN350, PN1.0
595
1780
71
23900
25100
6285
2190
3522
900
900
3165
272
544
102
2
DN300, PN1.0
669
94
2
DN350, PN1.0
573
1600
71
23400
24280
6285
2190
3522
Centrifugal Chiller system
R-134a single-stage series(550-650RT)
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
MHC-AS(550-650)H/A(B)(C)N3
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant ejecting R134a charging volume
380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
R134a charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unit dimensions
650
650
2285
196
393
112
3
DN250
490
92
3
DN250
428
700
83
13590
13340
4390
1965
2666
600
600
2110
181
362
112
3
DN250
452
92
3
DN250
402
670
83
13360
13040
4390
1965
2666
550
550
1934
166
332
112
3
DN250
415
92
3
DN250
372
640
83
13160
12770
4390
1965
2666
D
E
F
G
H
J
K
L
Supportmm
mm
mm
mm
mm
mm
mm
mm
3340
1730
585
540
620
940
877
1277
3340
1730
585
540
620
940
877
1277
3340
1730
585
540
620
940
877
1277
Connect pipesetting
dimensions
R-134a single-stage series (700-850RT)
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
MHC-AS(700-850)H/A(B)(C)N3
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant ejecting R134a charging volume
380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
R134a charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unit dimensions
850
850
2988
257
514
110
2
DN300
627
81
2
DN300
563
890
83
16230
15650
6013
2020
2830
800
800
2813
242
484
94
2
DN250
604
78
2
DN250
527
760
83
15060
14560
5638
1890
2646
750
750
2637
226
454
92
2
DN250
567
75
2
DN250
495
760
83
14890
14310
5638
1890
2646
D
E
F
G
H
J
K
L
Supportmm
mm
mm
mm
mm
mm
mm
mm
4740
1690
495
540
440
920
860
1280
4740
1690
495
540
440
920
860
1280
5040
1820
610
590
510
980
992
1448
Connect pipesetting
dimensions
700
700
2461
211
424
92
2
DN250
529
72
2
DN250
464
700
83
14650
13990
5638
1890
2646
4740
1690
495
540
440
920
860
1280
17 18
Centrifugal Chiller system
R-134a single-stage series (900-1100RT)
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
MHC-AS(900-1100)H/A(B)(C)N3
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant ejecting R134a charging volume
380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
R134a charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unit dimensions
1100
1100
3516
332
664
109
2
DN300
830
95
2
DN300
724
1000
102
17720
17500
6013
2180
2830
1000
1000
3516
302
605
86
2
DN300
735
78
2
DN300
651
950
102
17290
16070
6013
2020
2830
950
950
3340
287
574
105
2
DN300
696
81
2
DN300
610
950
102
16820
16070
6013
2020
2830
D
E
F
G
H
J
K
L
Supportmm
mm
mm
mm
mm
mm
mm
mm
5040
1820
610
590
510
980
992
1448
5040
1820
610
590
510
980
992
1448
5040
1940
610
590
510
1050
935
1448
Connect pipesetting
dimensions
900
900
3164
272
544
108
2
DN300
658
81
2
DN300
584
890
102
16560
16070
6013
2020
2830
5040
1820
610
590
510
980
992
1448
R-134a double-stage series (1200-2000RT)
Remarks:1. cooling water inlet/outlet temperature :12/7OC chilled water inlet/outlet temperature: 32/37OC waterside fouling factor : 0.086m2OC/kW2. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JB/T81-94. Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa. 3. The listed data in those samples may change, please refer to factory drawings offered by our company for standard.
19 20
MHS-AD(1200-2000)H/A(B)(C)N3
Cooling water flow
Cooling waterpressure drop
Number of pass
Connect pipenominal diameter
Chilled water flow
Chilled waterpressure drop
Number of pass
Connect pipenominal diameter
Capacity
Power supply
Coolingsystem Refrigerant liquid ejecting-evaporating380/6000/10000-3-50
Evaporator
Condenser
Motor
Unit Model
Refrigerating capacity
RT
kW
104kcal/h
m3/h
mm
m3/h
mm
kW
V-ph-HZ
KPa
KPa
R134a charge volume kg
kg
kg
kg
mm
mm
mm
Lubricant oil charge volume
Unit weightUnit transport Weight
Unit running weight
Length (A)
Width (B)
Height (C)
Unit dimensions
2000
2000
7032
605
1210
110
2
DN400
1465
88
2
DN400
1228
1600
150
29500
32100
6150
3200
3270
1800
1800
6329
544
1088
106
2
DN400
1320
86
2
DN400
1108
1500
150
28800
30800
6150
3200
3270
1650
1650
5800
500
998
104
2
DN350
1208
86
2
DN350
1014
1250
150
28150
29350
6150
3160
3120
D
E
F
G
H
J
K
L
Supportmm
mm
mm
mm
mm
mm
mm
mm
1230
1030
750
715
600
1330
1160
1740
1330
1030
820
765
650
1380
1260
1840
1330
1030
820
765
650
1380
1260
1840
Connect pipesetting
dimensions
1500
1500
5274
453
907
103
2
DN350
1096
85
2
DN350
922
1150
125
25600
27750
6150
3000
3120
1230
930
750
715
600
1280
1140
1660
1350
1350
4747
408
816
108
2
DN350
987
83
2
DN350
830
1080
125
24600
26400
6150
2900
3070
1130
930
700
660
600
1230
1140
1660
1200
1200
4219
363
726
108
2
DN350
874
83
2
DN350
740
1020
125
23700
25500
6150
2900
3070
1130
930
700
660
600
1230
1140
1660
Centrifugal Chiller system
Water-cooledScrew Chiller system
[ C ] Series
Notices for orderUsers should offer technical requirements as follow:
Cooling capacity
Inlet temperature of chilled water
Outlet temperature of chilled water
Inlet/outlet temperature of cooling water
Cooling/chilled water side fouling factors for special requirement (m2.0C/kW)
Whether there is different piping azimuth comparing with the sample
Voltage level of main motor
Special control requirements
Cooling/chilled water pressure for special requirement
Special instructionUser should self-supply base steel plate and cables between start cabinet and motor.
We suggest utilizing special refrigerant filler and charger to avoid refrigerant loss and leakage.
We supply two types of refrigerant fillers and chargers and relative refrigerant storages for user,
which is not belong to supply scope of our company, please contact with sale department of our
company for order.
Supply scope of a set centrifugal chiller systemA centrifugal compressor (include speeding-up device)
A main motor (motor cooled with refrigerant)
An evaporator and condenser
A refrigerant purifier (only applicable to series of R-123 single and dual-stage unit)
One lubricating system
An electric control cabinet (self-supply cables between electric box start cabinet)
A start cabinet (will supplied by user when main motor voltage is 6000v or 10000v)
A power saver (available for R123 and R-134a dual-stage series)
21
Screw Chiller system
Advanced screw dual-compressor technologyAdopts advanced industrial generation * compressor with 5-6 asymmetry dentiform design, the mechanical
configuration of which is manufactured by CNC high precision screw rotor, each part is well-proportioned,
no gap matching, minimizes the friction resistance, guarantees quiet running and well duration. Comparing
with single screw compressor has the advantages of no clearance loss, high volume efficiency, low running
noise, less damageable parts, etc.
23 24
HOW TO READ THE MODELS ?
M H S - A F 650 S / A N3
Midea
Screw Chiller
Compression Quantity:A Single Compressor
D Dual Compressor
Evaporator Type:F Flooded Type
D Dry Type
Power Type:A 6000V/50Hz/3PhB 10000V/50Hz/3PhC 380V/50Hz/3Ph
Compressor Type:H HemeticS Semi-hermeticO Opening
Heavy Commercial Chiller System
Refrigerant Type:N3 R134a
N5 R123
- R22
Nominal Cooling Capacity (USRT)
Screw Chiller system
Four-step capacity adjustment
Stepless capacity adjustment
100%
75%
50%
25%
100%75%50%25%
Capacity output
Capacity demand
Variable volume adjustment, High efficiency & energy-savingOwning the biggest single compression ratio, the ratio can reach up to 18.Compressor with adjustable variable volume and special volume control valve for precise control enables to adjust compressor's refrigerant compressed amount precisely matching with load change. Realizes 4-stage capacity output control (25%, 50%, 75%, and 100%) and stepless capacity control (need special instruction for the function on order). The high precise adjustable volume directly saves user's operation cost.
Adopting the world-famous brand key components, ensures the unit running with reliability & safety.
Introduction of components
CompressorAdopts high efficiency screw compressor of generation * with 5-6 asymmetry dentiform, the screw rotor of which gained patent by improving the shape of German rotor GHH, proved having well balance, small vibration, low noise due to balance testing by balance machine. Heat efficiency of the rotor with main and subsidiary rotor adopting 5-6 dentiform increases by 10-12% and energy saves by 25%, comparing with Chinese normal screw rotor with 4-6 dentiform. The rotor shape also gained British and American patent.Adopts compressor bearing SKF from Sweden, the long lifespan of which ensure screw-type main unit to run continuously more than 50000 hours.
Oil separatorThe product comes from MANN of German, has reliable qualification, oil content can be controlled below 3ppm (oil content treated by oil-gas separator of common domestic like screw-type air compressor is not less than 8-10ppm). oil-gas separated amount is double of same kind of products, the large oil filtering area reduces refrigerant flux speed, and has better separating effect and long lifespan by adopting secondary reflux technology.
CondenserMidea screw chiller is equipped with high efficiency shell and tube condenser, it is constructed by seamless steel tube with anti-corrosive treatment, the pressurization is 1.9Mpa, and the pressurization of water pipe side is 1.0Mpa. water pipe constructed with seamless integrally finned copper attains optimal heat exchange efficient, two return passages of water flow and the straight water pipe is easy for cleaning and maintenance, both end covers are made of iron, the covers attached with protection valve and snuffle valve and etc are removable, makes it available for altering water piping arrangement. The condenser is mounted with devices as protection valve and snuffle valve, etc.
EvaporatorThe pressurization of direct expanding shell and tube evaporator wrapped with heat insulating and flameproof material is 1.4Mpa, the inner refrigerant evaporation pipe of which is constructed with seamless steel pipe together with internal-screw cooling fin, guarantees a high efficient heat transmission, the pressurization is 1.0 MPa. Water flowing along refrigerant pipe outside and the installation of the flashing PP makes chilled water to flow up-down along the chilled water clapboard, improves heat transmission efficiency.
Refrigeration cycleConsists of the high pressure check-valve, expansive valve, electromagnetic valve, bulbiform valve, display panel, water indicator, dry filter, etc. Each multiple evaporator inside has independent refrigerant cycle pipes, avoiding system imbalance.
25 26
Item123456789
Item1011121314151617
ContentsFilterRefrigerant (low pressure)MotorOil filterBearingCompressor rotorBearingDischarge pipeRefrigerant (high pressure mix with oil)
ContentsLubricantOil separatorRefrigerant (high pressure)CapillaryElectromagnetic valve (starting)Electromagnetic valve (50% energy output)Electromagnetic valve (75% energy output)Capability adjustment device
Refrigerant circulation and lubricating system
Screw Chiller system
Dry type (single compressor series)
27 28
Remarks:The cooling capacities above are tested on the following states.Evaporator inlet water 12OC, outlet water 7OCCondenser inlet water 30OC, outlet water 35OC
MHS-AD(85-140)S/CModel
Cooling capacity
Power input
Unit color
Dimension (L x W x H)
Compressor type
Compressor starting mode
Power supply
Fouling factor
Design working pressure
Capacity adjustment
Refrigerant type
No. of refrigerant circuits
Refrigerant flux adjustment device
Refrigerant weight
Condenser type
Condenser model and number
Condenser inlet pipe dimension
Condenser outlet pipe dimension
Cooling water flux volume
Evaporator type
Evaporator model and number
Evaporator inlet pipe dimension
Evaporator outlet pipedimension
Chilled water flux volume
Grey
'5-6 Asymmetry Dentiform Semi-hermetic Screw
Y-*
380V, 3N~50Hz
0.086m2 . 0C/kW
Water side pressure is 1.0MPa
50%,75%,100%
R22
1
Thermo-expansive valve
60
Shell and tube
UCW050A/2
Dry shell and tube
UCH050A/1
Protection deviceHigh/low pressure protections, over load protection,
phase sequence protection, water flux volume protection,oil level protection, discharge temperature protection.
Unit weight
Unit running weight
USRT
kW
kW
mm
kg
mm
mm
m3/h
mm
mm
m3/h
kg
kg
85
83
292
60
2970-850-1820
50
DN100
DN100
61
DN100
DN100
50
1830
2030
90
91
318
69
2970-850-1850
DN100
DN100
67
DN100
DN100
55
1870
2070
115
114
400
85
2990-850-1965
80
DN100
DN100
84
DN100
DN100
69
2250
2550
140
139
485
100
2995-1350-1465
90
DN100
DN100
101
DN125
DN125
83
2610
2910
Remarks:The cooling capacities above are tested on the following states.Evaporator inlet water 12OC, outlet water 7OCCondenser inlet water 30OC, outlet water 35OC
MHS-AD(40-70)S/CModel
Cooling capacity
Power input
Unit color
Dimension (L x W x H)
Compressor type
Compressor starting mode
Power supply
Fouling factor
Design working pressure
Capacity adjustment
Refrigerant type
No. of refrigerant circuits
Refrigerant flux adjustment device
Refrigerant weight
Condenser type
Condenser model and number
Condenser inlet pipedimension
Condenser outlet pipe dimension
Cooling water flux volume
Evaporator type
Evaporator model and number
Evaporator inlet pipe dimension
Evaporator outlet pipe dimension
Chilled water flux volume
Grey
'5-6 Asymmetry Dentiform Semi-hermetic Screw
Y-*
380V, 3N~50Hz
0.086m2 . 0C/kW
Water side pressure is 1.0MPa
50%,75%,100%
R22
1
Thermo-expansive valve
30
Shell and tube
UCW050A/2
Dry shell and tube
UCH050A/1
Protection deviceHigh/low pressure protections, over load protection,
phase sequence protection, water flux volume protection,oil level protection, discharge temperature protection.
Unit weight
Unit running weight
USRT
kW
kW
mm
kg
mm
mm
m3/h
mm
mm
m3/h
kg
kg
40
37
130
28
2520-800-1720
25
DN80
DN80
27
DN80
DN80
22
1160
1260
50
48
167
35
2540-800-1740
DN80
DN80
35
DN80
DN80
29
1320
1470
55
54
189
41
2940-800-1740
35
DN80
DN80
40
DN80
DN80
33
1400
1550
70
72
253
55
2940-800-1740
40
DN100
DN100
53
DN80
DN80
44
1670
1820
Dry type (single compressor series)
Screw Chiller system
Dry type (dual compressor series)
29 30
Remarks:The cooling capacities above are tested on the following states.Evaporator inlet water 12OC, outlet water 7OCCondenser inlet water 30OC, outlet water 35OC
MHS-DD(280-360)S/CModel
Cooling capacity
Power input
Unit color
Dimension (L x W x H)
Compressor type
Compressor starting mode
Power supply
Fouling factor
Design working pressure
Capacity adjustment
Refrigerant type
No. of refrigerant circuits
Refrigerant flux adjustment device
Refrigerant weight
Condenser type
Condenser model and number
Condenser inlet pipe dimension
Condenser outlet pipe dimension
Cooling water flux volume
Evaporator type
Evaporator model and number
Evaporator inlet pipe dimension
Evaporator outlet pipedimension
Chilled water flux volume
'5-6 Asymmetry Dentiform Semi-hermetic Screw
Y-*
380V, 3N~50Hz
0.086m2 . 0C/kW
Water side pressure is 1.0MPa
50%,75%,100%
R22
2
Thermo-expansive valve
120+180
Shell and tube
UCW050A/2
Dry shell and tube
UCH050A/1
Protection deviceHigh/low pressure protections, over load protection,
phase sequence protection, water flux volume protection,oil level protection, discharge temperature protection.
Unit weight
Unit running weight
USRT
kW
kW
mm
kg
mm
mm
m3/h
mm
mm
m3/h
kg
kg
280
277
970
200
3800-1540-1600
120+150
DN150
DN150
202
DN150
DN150
167
4630
5080
300
302
1057
218
3800-1540-1640
DN150
DN150
220
DN150
DN150
182
4870
5320
330
327
114
236
4100-1640-1700
150x2
DN150
DN80
238
DN150
DN150
197
5100
5600
360
359
1256
264
4600-1640-1760
180x2
DN200
DN200
262
DN200
DN200
216
5840
6340
Grey
180
179
628
132
3620-1350-1580
220
220
771
167
3620-1450-1700
Remarks:The cooling capacities above are tested on the following states.Evaporator inlet water 12OC, outlet water 7OCCondenser inlet water 30OC, outlet water 35OC
MHS-AD(165-245)S/CModel
Cooling capacity
Power input
Unit color
Dimension (L x W x H)
Compressor type
Compressor starting mode
Power supply
Fouling factor
Design working pressure
Capacity adjustment
Refrigerant type
No. of refrigerant circuits
Refrigerant flux adjustment device
Refrigerant weight
Condenser type
Condenser model and number
Condenser inlet pipe dimension
Condenser outlet pipe dimension
Cooling water flux volume
Evaporator type
Evaporator model and number
Evaporator inlet pipe dimension
Evaporator outlet pipedimension
Chilled water flux volume
Grey
'5-6 Asymmetry Dentiform Semi-hermetic Screw
Y-*
380V, 3N~50Hz
0.086m2 . 0C/kW
Water side pressure is 1.0MPa
50%,75%,100%
R22
1
Thermo-expansive valve
120
Shell and tube
UCW050A/2
Dry shell and tube
UCH050A/1
Protection deviceHigh/low pressure protections, over load protection,
phase sequence protection, water flux volume protection,oil level protection, discharge temperature protection.
Unit weight
Unit running weight
USRT
kW
kW
mm
kg
mm
mm
m3/h
mm
mm
m3/h
kg
kg
165
163
572
118
2995-1380-1550
100
DN125
DN125
119
DN125
DN125
98
1160
1260
DN125
DN125
131
DN125
DN125
108
1320
1470
150
DN150
DN150
162
DN150
DN150
133
1400
1550
245
245
859
180
3620-1460-1700
180
DN150
DN150
179
DN150
DN150
148
1670
1820
Dry type (single compressor series)
Screw Chiller system
31 32
Dry type (dual compressor series) Flooded type (single compressor series)
Remarks:The cooling capacities above are tested on the following states.Evaporator inlet water 12OC, outlet water 7OCCondenser inlet water 30OC, outlet water 35OC
Model
Current (A)
Capacity adjustment method
Capacity adjustment range (%)
Power supply
Automatic
25%,50%,75%,100% step or stepless adjustment
R22
380V, 3N~50Hz
Unit weight (kg)
Unit running weight (kg)
cooling water inlet/outlet temperature:12/7 OC.chilled water inlet/outlet temperature:30/35 OC.
waterside fouling factor:0.086m2 OC/kW.
120
120
420
77
140
Number of pass
Chilled water flow (t/h)
Chilled water pressure
drop (kpa)
Diam. of inlet/outlet
water pipe (mm)
Number of pass
Cooling water flow (t/h)
Cooling water
pressure drop (kpa)
Diam. of inlet/outlet
Water pipe (mm)
Same technique parameter
Condensor
Evaperator
145
145
510
94
163
170
171
600
110
195
190
188
660
122
218
215
214
750
139
250
235
233
820
152
276
255
256
900
166
300
210
3
86
220
3
104
230
3
123
240
3
136
250
3
156
270
3
167
280
3
185
85
DN125
85
DN125
85
DN125
85
DN150
85
DN150
85
DN150
85
DN150
80
DN125
80
DN125
80
DN125
80
DN150
80
DN150
80
DN150
80
DN150
3
72
3
88
3
103
3
114
3
129
3
141
3
155
3500
1160
1900
3050
3300
3500
1310
1900
3500
3800
3500
1310
1950
3700
4050
3600
1410
2000
3850
4250
3600
1460
2000
4150
4560
3600
1460
2100
4550
5030
3600
1510
2100
5100
5550
Length (A)(mm)
Width (B)(mm)
Height (C)(mm)
Dimensions
MHS-AF(120-255)S/C
USRT
kW
kW
Cooling capacity
Power input
Type
Charge volume (kg)Refrigerat
Remarks:The cooling capacities above are tested on the following states.Evaporator inlet water 12OC, outlet water 7OCCondenser inlet water 30OC, outlet water 35OC
MHS-DD(400-490)S/CModel
Cooling capacity
Power input
Unit color
Dimension (L x W x H)
Compressor type
Compressor starting mode
Power supply
Fouling factor
Design working pressure
Capacity adjustment
Refrigerant type
No. of refrigerant circuits
Refrigerant flux adjustment device
Refrigerant weight
Condenser type
Condenser model and number
Condenser inlet pipe dimension
Condenser outlet pipe dimension
Cooling water flux volume
Evaporator type
Evaporator model and number
Evaporator inlet pipe dimension
Evaporator outlet pipe dimension
Chilled water flux volume
'5-6 Asymmetry Dentiform Semi-hermetic Screw
Y-*
380V, 3N~50Hz
0.086m2 . 0C/kW
Water side pressure is 1.0MPa
45%,75%,100% 42%,75%,100% 50%,75%,100%
R22
2
Thermo-expansive valve
90+100
Shell and tube
UCW050A/2
Dry shell and tube
UCH050A/1
Protection deviceHigh/low pressure protections, over load protection,
phase sequence protection, water flux volume protection,oil level protection, discharge temperature protection.
Unit weight
Unit running weight
USRT
kW
kW
mm
kg
mm
mm
m3/h
mm
mm
m3/h
kg
kg
400
400
1399
299
4800-1640-1810
90x2
DN200
DN200
293
DN200
DN200
241
6240
6790
425
425
1487
312
4800-1690-1865
DN200
DN200
310
DN200
DN200
256
6490
7090
440
441
1542
334
4800-1740-1865
100x2
DN200
DN200
323
DN200
DN200
265
6620
7220
490
491
1718
360
4800-1740-1865
120x2
DN200
DN200
358
DN200
DN200
295
6930
7630
Grey
Air-cooled ModularChiller System
[ A ] Series
Screw Chiller system
33
Flooded type (dual compressor series)
Remarks:The cooling capacities above are tested on the following states.Evaporator inlet water 12OC, outlet water 7OCCondenser inlet water 30OC, outlet water 35OC
Automatic
25%,50%,75%,100% step or stepless adjustment
R22
380V, 3N~50Hz
Unit weight (kg)
Unit running weight (kg)
cooling water inlet/outlet temperature:12/7 OC.chilled water inlet/outlet temperature:30/35 OC.
waterside fouling factor:0.086m2 OC/kW.
290
290
1020
188
326
Number of pass
Chilled water flow (t/h)
Chilled water pressure
drop (kpa)
Diam. of inlet/outlet
water pipe (mm)
Number of pass
Cooling water flow (t/h)
Cooling water
pressure drop (kpa)
Diam. of inlet/outlet
Water pipe (mm)
Same technique parameter
Condensor
Evaperator
340
341
1200
220
390
375
375
1320
244
436
430
427
1500
278
500
460
461
1620
304
552
510
512
1800
332
600
340
2
208
400
2
246
420
2
271
450
2
309
500
2
334
520
2
370
85
DN200
85
DN200
85
DN200
85
DN200
85
DN200
85
DN200
80
DN200
80
DN200
80
DN200
80
DN200
80
DN200
80
DN200
2
176
2
206
2
228
2
258
2
278
2
310
4500
14600
1900
5850
6360
4500
1510
1950
6780
7350
4600
1560
2000
7750
8420
4600
1660
2000
8470
9230
4600
1710
2100
9250
10150
4600
1760
2100
9480
10420
Length (A)(mm)
Width (B)(mm)
Height (C)(mm)
Dimensions
ModelMHS-DF(290-510)S/C
Cooling capacity
Power input
USRT
kW
kW
Current (A)
Capacity adjustment method
Capacity adjustment range (%)
Power supply
Type
Charge volume (kg)Refrigerat
Air-cooled Modular Chiller System
General introductionAir-cooled heat-pump unit is a kind of central air conditioner which adopts air as the cooling (heating) source
and water as cooling (heating) medium. As a sort of integrated equipment, it need no cooling tower cooling
water pump boiler and corresponding auxiliary parts such as pipe system etc, which makes the structure
simpler, saves installation space, convenient maintenance and energy saving. Thus it is very suitable for
areas that are short of water. Air-cooled heat-pump unit is the first priority in the engineering design for the
following conditions:
Hot summer and cold winter.
No heating boiler and heating-supply pipe system.
Heating supply pipe system is unstable or the supplying time is short.
Need air-conditioning whole year.
Midea Commercial Digital scroll air-cooled heat-pump modular unit is designed and produced on the
basement of sufficiently absorbing the top technology in AC areas, adopting self-control components with
high quality which made by world famous producers. Moreover, after improvement, unit can run more
efficiently and more stably.
Midea Commercial air-cooled heat-pump modular unit can be used widely in civil construction of AC
engineering and industrial engineering, such as hotel, villa, restaurant, hospital, factory, etc. It is a wise
choice for areas where water is insufficient or there are strict limits on noise level and surroundings.
30kW 65kW 185kW
35 36
Accessories
Model Name Function Dimension (WxHxD)mm
KJR-08B1/E Wire controller
Control on & off and the running parameter of unit. At most can control 8 modules.
120x120x15 (front)+
87x55x48 (back)
WFS-1001-H Target-type flowmeter
Check the status of water flow and control the whole system... One unit only need one flowmeter.
1 inch screw thread (connect in the water pipe)
M G A - D 65 W / S N2
MDV
Product CategoryA Modular Air-cooled Chiller System
P Water-cooled Package Unit
H Heating Water System
Compressor TypeD Digital Scroll Compressor
F Fixed Speed Scroll Compressor
Power SupplyS 380V~, 50Hz, 3Ph
Outdoor Unit
Light Chiller System
RefrigerantN1 R410A N2 R407C
- R22
Cooling Capacity (Kw)
HOW TO READ THE MODELS ?
Air-cooled Modular Chiller System
System featuresModular design, flexible combination.
There are 3 types (30kw, 65kw, 200kw) and 5 basic units.
The maximum of the system is consisted of one main unit and 7 auxiliary units, and the capacity can be
up to 1480kW.
Adopts Digital Scroll compressor, capacity can be adjusted. (200kw module just adopt fix-speed scroll
compressor.)
High reliability and efficiency.
Easy connection between main unit and auxiliary unit.
Intelligentized control. Strong Micro-computer automatic control function, more than twelve self-protect
and self-diagnose functions.
AdvantagesModular design, easy for capacity extension
Adopting modular design, numbers of modules can be assembled by connecting each own inlet & outlet
pipeline in series. The integrated system has a bigger capacity. The min. capacity is 30kW and the max. is
1480 kW. Furthermore, any of unit can be set as main unit, so both the design and installation are very
flexible. Convenient combination, auto control, available capacity adjustment
Digital and constant module unit can be
combined by simple pipe and signal wiring
connection. The capacity output can be
adjusted and the load of different module unit
can be distributed uniformly by control system.
The unit system can adjust output according
to requirement without energy waste.
37 38
Since traditional air cooled chiller system adjusts energy output by turning ON/OFF the compressor, the
capacity output is not accurate as Digital Scroll compressor. Midea modular air-cooled chiller system
combines digital scroll compressor with constant speed compressor, which can steplessly adjust the capacity
output from 0.5 to 100%. In the state of partial capacity loading, the system can adjust the capacity output
precisely according to each indoor unit's requirement.
A dopt digital scroll technology, new air-cooled modular design
Energy output for traditional modular air cooled chiller system
(0%) OFF
(100%) ON
Energy output for digital modular air cooled chiller system
25%
75%
100%
50%
0.5%
capacity output2.6 130 260 390 520kw
Ratio
65kw digital model 65kw fixed model
195KW260KW
325KW390KW
520KW
130KW
100%
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
45%
40%
35%
30%
25%
20%
15%
10%
65KW
455KW
Capacity output ratio %
Indoor unit capacity need
+ + =
1480kW185kW
520kW65kW
+ + =
Air-cooled Modular Chiller System
PMV refrigerant flow adjustment Traditional modular chiller adopts thermo-expansion valve for adjusting, but it cannot adjust refrigerant flow accurately and also will be delay. So it makes the room temperature fluctuating too much that users may be uncomfortable.
High efficient heat exchangerFor the 30 or 65kw module, we use plate heat-exchanger, and for the 200 kw module, we use shell-and-tube heat-exchanger.
Chiller water outlet temperature can be adjusted Water outlet temperature can be adjusted according to customers' demand. In cooling mode, the adjustable ranges from 70C to 120C, and in heating mode, it ranges from 450C to 500C.
Simple controlThe wire connection is very simple between modules. The signal wiring connection between two units of 65kW module is finished before launch. The two-cores Shielded Twisted Pair is used for signal wire. Each unit can be controlled and monitored by the wiring controller that just connects to main unit.
Strong and reliable control systemStepless capacity modulation, more efficiencyOperation mode controlAutomatic and uniform adjusting function among multi compressorsAnti-frost and anti-cold air function in heating modeAnti-freezing function of water system in winterSelf-protection and Self-diagnosis function:
Compressor low and high pressure protection
Phase sequence protection
Anti-frost protection on cooling mode
Anti-frost protection in winter
Start continually protection
Compressor over current protection
Compressor discharge temp. protection
Unit Anti-overheat protection
Auxiliary heater protection
Ensure compressor operate on proper temp. range.
Prevent compressor from damaging by wrong phase sequence
Prevent evaporator, water pipe or other parts from damaging by low evaporator temp.
Prevent evaporator, water pipe or other parts from damaging by low ambient temp.
Water flow switch protection
Prevent compressor from damaging by continually start which come of malfunction
Prevent compressor from burning out by over current on abominable weather.
Ensure compressor operate in a good condition.
Prevent compressor from burning out for running on lacking refrigerant or oil.
Prevent auxiliary heater from damaging by over high temperature.
Prevent unit from damaging by lack of water.
Sensor malfunction protection Ensure sensor collect correct information so that control system will not make wrong action.
Specification
Notes:1. Each module is packed separately and the packing size refers to one module only.2. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.3. Nominal capacities are based on the following conditions: Cooling condition: chilled water inlet/outlet: 12OC/7OC. Outdoor temp:35OC(DB)/24OC(WB) Heating condition: warm water inlet/outlet: 40OC/45OC. Outdoor temp:7OC(DB)/6OC(WB)4. Water side fouling factor: 0.086m2 . OC/kw.
MGA-D(30-240)W/S(N2) or MGA-F(30-240)W/S(N2)
380V 3N~ 50Hz
Wire control. Manual or automatic startup, the running status display and malfunction alarm, etc.
High/low-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection.
Both R22 and R407C are available
29.4
Welding, stainless steel, plate heat exchanger
1.0
133mm
Fin coil
1514
1820
L x W x H (1620 x 1034 x 2041)
Model
Cooling Capacity
Heating Capacity
Cooling input
Heating input
Power supply
Control type
Safety protection device
Main module + auxiliary module
Compressor input kW
Refrigerant
Refrigerant
Water system
Air sideheat-exchanger
Dimension
Total weight
Packing
Optional auxiliary heater
kW
1000 kcal/h
kW
1000 kcal/h
kW
kW
kg
Water flow volume m3/h
Water resistance loss kPa
Waterside heat-exchanger
Max. Pressure MPa
Water inlet/outlet pipeline diameter
Type
Air flow volume 103m3/h
Fan motor input kWL mm
W mm
H mm
kg
mm
kw
30
30
25.8
32
27.5
10
9.8
1+0
9
4.5x2
5.2
12
0.7x1
850
7.5
440
60
60
51.6
64
55
20
19.5
1+2
18
4.5x4
10.3
24
0.7x2
2300
15
880
90
90
77.4
96
82.6
30
29.3
1+3
27
4.5x6
15.5
36
0.7x3
2450
22.5
1320
120
120
103.2
128
110.1
40
39.0
1+4
36
4.5x8
20.6
48
0.7x4
4600
30
1760
150
150
129
160
137.6
50
48.8
1+5
45
4.5x10
25.8
60
0.7x5
5750
37.4
2200
180
180
154.8
192
165.1
60
58.8
1+6
54
4.5x12
30.9
72
0.7x6
6900
45
2640
210
210
180.6
224
192.7
70
68.3
1+7
63
4.5x14
36.0
84
0.7x7
8050
52.5
3080
240
240
206.4
256
220.2
80
78.0
1+8
72
4.5x16
41.2
96
0.7x8
9200
60
3520
39 40
Air-cooled Modular Chiller System
Specification
Notes:1. Each module is packed separately and the packing size refers to one module only.2. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.3. Nominal capacities are based on the following conditions: Cooling condition: chilled water inlet/outlet: 12OC/7OC. Outdoor temp:35OC(DB)/24OC(WB) Heating condition: warm water inlet/outlet: 40OC/45OC. Outdoor temp:7OC(DB)/6OC(WB)4. Water side fouling factor: 0.086m2 . OC/kw.
MGA-D(270-480)W/S(N2) or MGA-F(270-480)W/S(N2)
380V 3N~ 50Hz
Wire control. Manual or automatic startup, the running status display and malfunction alarm, etc.
High/low-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection.
Both R22 and R407C are available
29.4
Welding, stainless steel, plate heat exchanger
1.0
133mm
Fin coil
1514
1820
L x W x H (1620 x 1034 x 2041)
Model
Cooling Capacity
Heating Capacity
Cooling input
Heating input
Power supply
Control type
Safety protection device
Main module + auxiliary module
Compressor input kW
Refrigerant
Refrigerant
Water system
Air sideheat-exchanger
Dimension
Total weight
Packing
Optional auxiliary heater
kW
1000 kcal/h
kW
1000 kcal/h
kW
kW
kg
Water flow volume m3/h
Water resistance loss kPa
Waterside heat-exchanger
Max. Pressure MPa
Water inlet/outlet pipeline diameter
Type
Air flow volume 103m3/h
Fan motor input kWL mm
W mm
H mm
kg
mm
kw
270
270
23.2
288
247.5
90
87.8
1+8
81
4.5x18
46.4
108
0.7x9
12450
67.5
3960
300
300
258
320
275
100
97.5
1+9
90
4.5x20
51.5
120
0.7x10
13900
75
4400
330
330
283.8
352
302.5
110
107.3
1+10
99
4.5x22
56.7
132
0.7x11
25350
82.5
4480
360
360
309.6
384
330
120
117.0
1+11
108
4.5x24
61.8
144
0.7x12
16800
90
5280
390
390
335.4
416
357.5
130
126.8
1+12
117
4.5x26
67.0
156
0.7x13
18250
97.5
5720
420
420
361.2
448
385
140
136.5
1+13
126
4.5x28
72.1
168
0.7x14
19700
105
6160
450
450
387
480
412.5
150
146.3
1+14
135
4.5x30
77.3
180
0.7x15
21150
112.5
6600
480
480
412.8
512
440
160
156.0
1+15
144
4.5x32
82.4
192
0.7x16
22600
120
7040
Specification
Notes:1. Each module is packed separately and the packing size refers to one module only.2. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.3. Nominal capacities are based on the following conditions: Cooling condition: chilled water inlet/outlet: 12OC/7OC. Outdoor temp:35OC(DB)/24OC(WB) Heating condition: warm water inlet/outlet: 40OC/45OC. Outdoor temp:7OC(DB)/6OC(WB)4. Water side fouling factor: 0.086m2 . OC/kw.
MGA-D(65-520)W/S(N2) or MGA-F(65-520)W/S(N2)
380V 3N~ 50Hz
Wire control. Manual or automatic startup, the running status display and malfunction alarm, etc.
High/low-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection.
Both R22 and R407C are available
29.4
Welding, stainless steel, plate heat exchanger
1.0
133mm
Fin coil
2492
1820
L x W x H (2612 x 1034 x 2041)
Model
Cooling Capacity
Heating Capacity
Cooling input
Heating input
Power supply
Control type
Safety protection device
Main module + auxiliary module
Compressor input kW
Refrigerant
Refrigerant
Water system
Air sideheat-exchanger
Dimension
Total weight
Packing
Optional auxiliary heater
kW
1000 kcal/h
kW
1000 kcal/h
kW
kW
kg
Water flow volume m3/h
Water resistance loss kPa
Waterside heat-exchanger
Max. Pressure MPa
Water inlet/outlet pipeline diameter
Type
Air flow volume 103m3/h
Fan motor input kWL mm
W mm
H mm
kg
mm
kw
65
65
55.9
69
59.3
21.5
21
1+0
18.5
4.5x4
11.2
24
0.7x2
850
15
700
130
130
111.8
138
118.7
43
42
1+1
37
4.5x8
22.4
48
0.7x4
2300
30
1400
195
195
167.7
207
178.0
64.5
63
1+2
55.5
4.5x12
33.6
72
0.7x6
3450
40
2100
260
260
223.6
276
237.4
86
84
1+3
74
4.5x16
44.8
96
0.7x8
4600
60
2800
325
325
279.5
345
296.7
107.5
105
1+4
92.5
4.5x20
56.0
120
0.7x10
5750
75
3500
390
390
335.4
414
356.0
129
126
1+5
111
4.5x24
67.2
144
0.7x12
6900
90
4200
455
455
391.3
483
415.4
150.5
147
1+6
129.5
4.5x28
78.4
168
0.7x14
8050
105
4900
520
520
447.2
552
474.7
172
168
1+7
148
4.5x32
89.6
192
0.7x16
9200
120
5600
41 42
Remarks:1. For the 30kw and 65kw system, if electrical two-way valve used for all terminals and they are all closed when main unit is operating, the plate exchanger may be damaged. So pass-by adjusting valve should be set in the system.2. If there is no any pass-by adjusting valve in the system, the number of fan coil with two-way water valve should not over 50%.
Air-cooled Modular Chiller System
Specification
Notes:1. Each module is packed separately and the packing size refers to one module only.2. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.3. Nominal capacities are based on the following conditions: Cooling condition: chilled water inlet/outlet: 12OC/7OC. Outdoor temp:35OC(DB)/24OC(WB) Heating condition: warm water inlet/outlet: 40OC/45OC. Outdoor temp:7OC(DB)/6OC(WB)4. Water side fouling factor: 0.086m2 . OC/kw.
Pipe system connectionSketch of (30, 65kw) module connection
Sketch of 200kw module connection Single module:
Multi modules (we recommend the following two types:)
Water flow switch
Cutoff valve
Water drain valve
Check valve
Adjusting valve
Flow gauge
Filter
Themometer
Pressure gauge
Soft connector
Water pump
Expansion tank
Module
Water pump(main)
Water pump (auxiliary)
Bleeder pipe Bleeder supplier
Water inlet
Water outlet
43 44
BA
Evaporator
No.8 Module No.1 Module(main)
Evaporator
Waterflowswitch
Temp.sensorof totalwater outletWater pipe
Water pump
Evaporator
No.8 Module No.1 Module(main)
Evaporator
Water flowswitch
Temp.sensorof totalwater outlet
Water pump Water pipe
waterdrainvalve
overflow water
connet PCBbox of O# unit
water pump
water flowswitch
thermometer
water supply valve
pressuregauge
expansion tank
auxilaryheater
cut-off valve
Fan coil
Main
modular
Auxiliary
modular1
Auxiliary
modular7Y shape
filtersoft
connectsoft
connect
water drain valve
automaticallygas dischargevalve
MGA-F(200-1600)W/S(N2)
380V 3N~ 50Hz
Wire control.
High/low-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection.
R22
15
Shell-and-tube, high efficiency heat-exchanger
1.0
Fin coil
2060
2430
L x W x H (3450 x 2250 x 2700)
Model
Cooling Capacity
Heating Capacity
Cooling input
Heating input
Power supply
Control type
Safety protection device
Main module + auxiliary module
Compressor input kW
Refrigerant
Refrigerant
Water system
Air sideheat-exchanger
Dimension
Total weight
Packing
Optional auxiliary heater
kW
1000 kcal/h
kW
1000 kcal/h
kW
kW
kg
Water flow volume m3/h
Water resistance loss kPa
Waterside heat-exchanger
Max. Pressure MPa
Water inlet/outlet pipeline diameter
Type
Air flow volume 103m3/h
Fan motor input kWL mm
W mm
H mm
kg
mm
kw
200
185
159
200
172
62
60
1+0
56
70
31.8
78
1.0x6
3210
3000
2720
400
370
318
400
344
124
120
1+1
112
140
63.6
156
1.0x12
7920
6000
5440
600
555
477
600
516
186
180
1+2
168
210
95.4
234
1.0x18
12600
9000
8160
800
740
636
800
688
248
240
1+3
224
280
127.2
312
1.0x24
17340
12000
10880
1000
1100
955
1200
1032
310
300
1+4
280
350
159.0
390
1.0x30
22050
15000
13600
1200
1295
1114
1400
1204
372
360
1+5
336
420
190.8
468
1.0x36
26760
18000
16320
1400
1480
1273
1600
1376
434
420
1+6
392
490
222.6
546
1.0x42
31470
21000
19040
1600
1480
447.2
1273
1600
496
480
1+7
446
560
254.4
624
1.0x48
36180
24000
21760
100 100 150 150 200 200 200 250
Water-Cooled Package Unit
Water-Cooled Package Unit
[ W ] Series
MGP-F35W/S MGP-F100W/S~MGP-F145W/S
FeaturesThe system adopt compliance scroll compressor with high efficiency, low noise level, stable performance
& high reliability.
Adopt advanced parallel system just as multi system, each compressor will run according to the load of
the system. It can save a lot of energy when operation at partial load;
Shell-tube condenser efficiently reduces the water jam and makes it easier to do clearance of water
system;
Microcomputer control technology makes the water pump and cooling tower can be easily controlled;
The touch screen make it is easy to operation;
The kinds of protection function makes the system safety and rhathymia;
The strong protection and malfunction detect makes the system easy for debugging and maintenance;
Polyester treatment technics, makes the beautiful appearance and good anti- erode ability;
Refrigerant: R22, R407CApply site: Factory, supermarket, restaurant, multiple shop and recreation.
Capacity range: 35kW-145kW
46
MGP-F60W/SMGP-F80W/S
Water-Cooled Package Unit
Dimension
Left side
Cooling water outlet
Cooling water inlet
Emergency drainage
MGP-F100W/SMGP-F120W/SMGP-F135W/SMGP-F145W/S
Air outlet
Top sideMGP-F35W/SMGP-F60W/SMGP-F80W/S
Air outlet
Top side
47 48
W1090142014201912191219121912
H1839183918391839183918391839
G1160149014901982198219821982
F1130146014601952195219521952
E410478478482482482482
D1055105510551055105510551055
C377558558434434434434
B///
632632632632
A241235235206206206206
ModelMGP-F35W/SMGP-F60W/SMGP-F80W/SMGP-F100W/SMGP-F120W/SMGP-F135W/SMGP-F145W/S
Unit: mm
Backside
Filter
Condenser drainage
585
Face
Pressure gauge
Installation hole(4- 15)
Touch screen
FG
H
W
Model
Type
Start-up modeCompressor Output
power
Lubricatingoil
Refrigeration
Wind-wheel
Fan motorMotor
Driving mode
Air volume
Static pressure
WaterVolume
Waterresistance
Diameterof inlet
wate pipeDiameterof outletwate pipe
Over-load protection, high/low pressure protection, anti-frost protection,and inner temp. Protection of compressor, phase-sequence
Cooling capacity
Rated power
EER
Rated current
Outlet of evaporator
Outlet of plate
Height(before/after)
length(before/after)
width(before/after)
Net/Cross weight
Protection device
High pressure protection
Low pressure protection
Noise
MGP-F120W/S
380V,3N~50Hz
Scroll
Direct start-up
1
MGP-F35W/S
35
8.75
4
17.8
3.6x2
1.8x2
8x1
1.5
6500
147
7.5
9806
40(1-1/2")
25(1")
25(1")
1839/2047
1090/1250
1055/1230
430/470
24
0.3
60
40(1-1/2")
1
MGP-F60W/S
60
15.2
3.95
30.9
3.05x4
1.8x4
8x2
2.8
11000
147
12.9
9806
65(2-1/2")
65(2-1/2")
25(1")
25(1")
1839/2047
1420/1640
1055/1230
690/723
24
0.3
62
25(1")
25(1")
1839/2047
1420/1640
1055/1230
700/733
24
0.3
66
1
MGP-F80W/S
4.0x4
1.8x4
9x2
3
14000
147
16.5
9806
65(2-1/2")
65(2-1/2")
80
19
3.95
37.2
2
MGP-F100W/S
3.05x6
1.8x6
8x3
Mineral oil
R22
Strap
5.3
18200
147
22.1
9806
65(2-1/2")
65(2-1/2")
25(1")
25(1")
1839/2047
1912/2152
1055/1230
820/870
24
0.3
70
100
23.8
4.07
45
2
8.0x3
3.0x3
9.0x3
5.5
20600
147
26.7
9806
65(2-1/2")
65(2-1/2")
25(1")
25(1")
1839/204
1912/21527
1055/1230
830/880
24
0.3
71
120
29.5
3.97
58.5
2
MGP-F135W/S
9.5x3
3.3x3
9.5x3
5.5
20600
230
28.8
9806
65(2-1/2")
65(2-1/2")
25(1")
25(1")
1839/2047
1912/2152
1055/1230
840/890
24
0.3
71
135
34.1
3.9
62.5
2
MGP-F145W/S
10.5x3
3.3x3
9.5x3
5.5
22000
250
30.9
9806
65(2-1/2")
65(2-1/2")
25(1")
25(1")
1839/2047
1912/2150
1055/1230
850/900
24
0.3
72
145
3.9
37.2
68.2
kW
kW
kW
W/W
A
kW
Standard
LType
kg
m3/h
Pa
Pa
mm/inch
mm/inch
mm/inch
mm/inch
mm
mm
mm
kg
kgf/cm2
kgf/cm2
dB(A)
m3/h
Power supply
CoolingWater Side
Specification
Heating Water System
[ R ] Series
Integrated design of main unit and tank makes it very conveniently using only by connecting the water inlet and outlet pipes.
Integrative
50
Based on reverse Carnot cycle principle, heating water system is one of the most advanced water heater with the highest COP. Heating water system generally consists of compressor, evaporator, expansion valve, strainer, accumulator tank, condenser, water tank.
Overview of heating water system
17.5kW 35kW
Compressor
Heat exchanger for air
Expansion Valve
Heat exchanger for water
Cool water
Water tank
Low temp.
High temperature Hot water
Hot waterAir inlet
The sketch of system connection
9.0kW7kW
Integrative
R407C R22
Heating Water System
51 52
Heating water system is environmentally friendly and low energy consuming.
Environmental Protection
Less additional operation charge; No need for transportation and storage of
fuel; simple maintenance and reparation.
COP up to 4.0.
Economical
Heating water system does not need storage of fuel and fuel pipe, therefore,
it is free of fuel leakage, fire and explosion.
The unit has multi-protection functions: high-pressure protection, low-pressure
protection, overflow and overload protection for compressor, startup delay,
water switch, water temperature overhigh protection and water level protection
of water tank.
Safety
Automatic intelligent controlling system defrosts automatically in cold winter.
Outdoor installation; no special equipment room needed.
Convenience
Famous brand compressor and plate heat exchanger equipped.
Quintuple antirust technique ensures excellent durability.
Durability
Within the temperature range from -10 to 400C, the heating water system can
work all year around, and perform well against bad weather.
Widely applicable
•
•
•
•
•
•
•
•
•
•
Installation sketch for single unit
Pipe choice
valvevalvevalvevalvevalvevalve
valvevalvevalvevalvevalvevalve
Heat p
ump
w
ater heater
Heat p
ump
w
ater heater
Heat p
ump
w
ater heater
Heat p
ump
w
ater heater
Heat p
ump
w
ater heater
Heat p
ump
w
ater heater
ON/OFF
Water tank
Drain valve
Pipe union
Pressure meter
Water pump Cutoff valve Water supply
Heat p
ump
w
ater heater
Filter
To user
Number of unit (set)
Pipe diameter (inch) 12
141-~1-1
411~1- 1-~212
1~3 4~6 7~9 10~12 13~16
2~3 3~4
Installation sketch for multi units
Water SourceHeat Pump
[ S ] Series
53
Model
Heating capacity
Rated power
Rated current
Hot water volume
Max power
Max current
380V 3N ~ 50HZ
kW
kW
A
m3/h
kW
A
Specification, power supply
Controlling method
Compressor (power x quantity)
Refrigerant
Refrigerant charge
Specification of
water system
MGH-F35W/S
35
9.0
16.6
1.0
11.8
20.2
MGH-F17.5W/S
17.5
4.5
8.6
0.5
5.8
9.8
Manual,Auto and failure alarm
R22/R407C
4.25kW x 2 4.25kW x 1
2300g x 2 2200g x 1
Outlet water temp
Heat exchanger(water side)
Diameter,water inlet pipe
Diameter,water outlet pipe
Max compression resistance
Type
Motor power
Type of air outlet
Length
Width
Height
kg
dB(A)
60 (default)
DN25
DN25
1.0Mpa
Heat exchanger
(gas side)
Demension
Weight
Noise level
250W x 2
Vertical air discharge
1290mm
750mm
1540mm
290
58
150W x 2
Side air discharge
940mm
340mm
1245mm
135
54
MGH-F9W
9.0
2.3
11.0
0.26
3.1
14.8
2.2kW x 1
1300g x 1
220V 1N ~ 50HZ
stainless steel plate heat exchanger
innergroove copper pipe,hydrophilic aluminum coil
DN20
DN20
1.0Mpa
DN15
DN15
1.0Mpa
125W
Vertical air discharge
555mm
555mm
840mm
77
52
MGH-F7W
7.0
2.0
10.0
0.16
2.3
14.0
1.9kW x 1
1000g x 1
DN15
DN15
0.8Mpa
100W
Side air discharge
900mm
530mm
1200mm
70
50
tube-tube heat exchanger
Specification
Heating Water System
Water Source Heat Pump
System sketch map
Save energy, environmental, healthy as the thematic of today's AC market, AC industry come into a new
stage. The Midea split water source heat pump unit can meet more and more requirement of the thematic,
and become the new start of AC industry.
Water Circle TypeShare the flow water in the water pipe as cooling/heating source. It can adopt crude water source as river
water, sea water, lake water, etc, even industry waste water or sewage can be adopted as the cooling/heating
source.
Example: 1. Electronic Water handler 2. Water circle pump 3. Soft connector 4. valve
5. water filter 6. cooling tower 7. water expansion tank
55 56
2 3 4
7
6
51
Top floor
Vertical pipe
N Floor
First floor
Other heatsource
Horizontal pipe AC system
Copper pipe Copper pipe Copper pipe
HOW TO READ THE MODELS ?
M S H - 12 W / S
Midea
H: Heating And CoolingC: Cooling Only
Nominal Capacity: kW
Outdoor Unit
Water Source Heat Pump
Power SupplyS: 380V~, 50Hz, 3Ph
- 220-240V~, 50Hz, 1Ph
Water Source Heat Pump
Stable and reliable Simple system design, reliable performance.
Water cooled heat exchange, high efficiency and stable operation.
Easy enlarge the capacity, Save investmentIt can invest and install the system for some building by stages while do not affect the project design
and save early days investment.
Set aside water pipe connector on public water source, so that easy for enlarging the capacity.
Various of indoor unitVarious of indoor unit, flexible equipment selection.
The system can be installed in covert place, do not affect the holistic layout of the building.
Water source low static pressure duct
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWdB(A)kgW(mm)D(mm)H(mm)m3/hmm
DN(mm)DN(mm)
CoolingHeatingNoise levelweight
Input
380V-50Hz-3N
Indoor unitDimension
R22
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Ari volumeGas PipeLiquid Pipe
14704902401250
16104902401700
16104902401800
MTA2-48HR14.015.0
3.53.6
43/3836
19.012.72032
MTA2-48CR14.0/
3.5/
43/3836
19.012.72032
MTA2-42HR12.014.0
3.23.3
43/3836
19.012.72032
MTA2-42CR12.0/
3.2/
43/3836
19.012.72032
MTA2-24HR7.18.0
1.92.0
42/3830
15.99.532032
MTA2-24CR7.1/
1.9/
42/3830
15.99.532032
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWdB(A)kgW(mm)D(mm)H(mm)m3/hmm
DN(mm)DN(mm)
CoolingHeatingNoise levelweight
Input
220V-50Hz
Indoor unitDimension
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Ari volumeGas PipeLiquid Pipe
12474902401000
14704902401250
MTA2-18CR5.0/
1.3/
41/3726
12.76.352032
MTA2-18HR5.06.0
1.31.4
41/3726
12.76.352032
MTA2-24CR7.1/
1.9/
42/3830
15.99.532032
MTA2-24HR7.18.0
1.92.0
42/3830
15.99.532032
R22
57 58
FeaturesEnvironmental-friendly and save energyAdopt the ground water, lake water, etc, do not
pollute the environment.
Water cooled type with high heat exchange ratio.
It is very suitable for some place where requirement
heating and cooling at the same time.
Remarks:1. Cooling condition: Indoor temperature: 27OC(DB)/19OC(WB), water inlet temperature: 30OC;2. Heating condition: Indoor temperature: 20OC(DB), water inlet temperature: 20OC;
Ultra thin body, space saving and easy installation.Quiet operation, low noise.
Installed in the ceiling, and save much sapce.Four directions and large scale of air flow, create a much more comfortable space.
Water Source Heat Pump
Water source four way cassette Water source high static pressure duct
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWdB(A)kgW(mm)D(mm)H(mm)m3/hmm
DN(mm)DN(mm)
CoolingHeatingNoise levelweight
Input
380V-50Hz-3N
Indoor unitDimension
R22
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Ari volumeGas PipeLiquid Pipe
840/950840/950230/461020
840/950840/950300/461800
840/950840/950300/461800
MCA-48HR14.015.0
3.53.6
44/3835/6
19.012.72032
MCA-48CR14.0/
3.5/
44/3835/6
19.012.72032
MCA-42HR12.014.0
3.23.3
41/3635/6
19.012.72032
MCA-42CR12.0/
3.2/
41/3635/6
19.012.72032
MCA-24HR7.18.0
1.92.0
39/3525/6
15.99.532032
MCA-24CR7.1/
1.9/
39/3525/6
15.99.532032
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWdB(A)kgW(mm)D(mm)H(mm)m3/hmm
DN(mm)DN(mm)
CoolingHeatingNoise levelweight
Input
220V-50Hz
Indoor unitDimension
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Ari volumeGas PipeLiquid Pipe
840/950840/950230/461020
840/950840/950230/461020
MCA-18HR5.06.0
1.31.4
39/3425/6
12.76.352032
MCA-18CR5.0/
1.3/
39/3425/6
12.76.352032
MCA-24CR7.1/
1.9/
39/3525/6
15.99.532032
MCA-24HR7.18.0
1.92.0
39/3525/6
15.99.532032
R22
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWdB(A)kgW(mm)D(mm)H(mm)m3/hmm
DN(mm)DN(mm)
CoolingHeatingNoise levelweight
Input
220V-50Hz
Indoor unitDimension
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Ari volumeGas PipeLiquid Pipe
8506603801200
8506603801600
MHA-18HR5.06.0
1.31.4
44/3952
12.76.352032
MHA-18CR5.0/
1.3/
44/3952
12.76.352032
MHA-24CR7.1/
1.9/
44/3952
15.99.532032
MHA-24HR7.18.0
1.92.0
44/3952
15.99.532032
R22
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWdB(A)kgW(mm)D(mm)H(mm)m3/hmm
DN(mm)DN(mm)
CoolingHeatingNoise levelweight
Input
380V-50Hz-3N
Indoor unitDimension
R22
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Ari volumeGas PipeLiquid Pipe
8506603801600
12006603803200
12006603803200
MHA-48HR14.015.0
3.53.6
44/4067
19.012.72032
MHA-48CR14.0/
3.5/
44/4067
19.012.72032
MHA-42HR12.014.0
3.23.3
44/4067
19.012.72032
MHA-42CR12.0/
3.2/
44/4067
19.012.72032
MHA-24HR7.18.0
1.92.0
44/3952
15.99.532032
MHA-24CR7.1/
1.9/
44/3952
15.99.532032
59 60
Remarks:1. Cooling condition: Indoor temperature: 27OC(DB)/19OC(WB), water inlet temperature: 30OC;2. Heating condition: Indoor temperature: 20OC(DB), water inlet temperature: 20OC;
Remarks:1. Cooling condition: Indoor temperature: 27OC(DB)/19OC(WB), water inlet temperature: 30OC;2. Heating condition: Indoor temperature: 20OC(DB), water inlet temperature: 20OC;
Quite high external static pressure, long distance air supply.Fresh air drawing, healthier and more comfortable for you.
Fan Coil Unit
[ K ] Series
Water Source Heat Pump
61
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWL/s
CoolingHeatingWater Volume
Input
220V-50Hz
Outdoorunit
Dimension
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Gas PipeLiquid Pipe
MSH-5W MSC-7W MSH-7W
R22
Waterresistance kPa
Noise levelweight
dB(A)kgW(mm)D(mm)H(mm)mmmmDN(mm)DN(mm)
MSC-5W5.0/
1.3/
0.36
423875434044712.76.352032
24
5.06.0
1.31.40.36
424075434044712.76.352032
24
7.1/
1.9/
0.51
424867434057415.99.532032
25
7.18.0
1.92.00.51
425067434057415.99.532032
25
ModelCooling CapacityHeating CapacityPower Supply
kWkW
kWkWL/s
CoolingHeatingWater Volume
Input
380V-50Hz-3N
Outdoorunit
Dimension
ConnectionPipe
Water Inlet/Outlet PipeCondenser Water PipeRefregeration
Gas PipeLiquid Pipe
R22
Waterresistance kPa
Noise levelweight
dB(A)kgW(mm)D(mm)H(mm)mmmmDN(mm)DN(mm)
MSC-7W/S7.1/
1.9/
0.51
424867434057415.99.532032
25
MSH-7W/S7.18.0
1.92.00.51
425067434057415.99.532032
25
MSC-12W/S12.0/
3.2/
0.91
457779034057419.012.72032
32
MSH-12W/S12.014.0
3.23.30.91
458079034057419.012.72032
32
MSC-14W/S14.0/
3.5/
1.02
457779034057419.012.72032
32
MSH-14W/S14.015.0
3.53.61.02
458079034057419.012.72032
25
Remarks:1. Cooling condition: Indoor temperature: 27OC(DB)/19OC(WB), water inlet temperature: 30OC;2. Heating condition: Indoor temperature: 20OC(DB), water inlet temperature: 20OC;
Entire system design, easier installation and save spacing.High efficiency heat-exchanging,hence brings high EER.Anti-corrosive cabinet, stable running and long life-span.
Air Handling Unit
Air Handling UnitAir Handling Unit & Fan Coil Unit
Brief introductionMidea fan coil unit be made from high quality galvanization, the beautiful and thin body makes it save a lot
of space and easy for installation. The big air volume makes a symmetrical room temperature so do not
get harm to people at the same time. The advanced technology and high quality material reduced the noise
level, it is widely used in marketplace, hospital, office, hotel, airport, etc.
Midea air handling unit have six series production as single wall horizontal type, single wall vertical type,
single wall-mounted type, dual wall horizontal type, dual wall vertical type and dual wall-mounted type. Air
flow volume ranges from 2000m3/h to 60000m3/h, cooling capacity ranges from 6kW to 985kW, heating
capacity ranges from 11kW to 1100kW.
Midea air handling unit has been tested by national AC quality supervise testing center, as low noise level,
high efficiency, stable operation and low power consumption make it as the advanced production in the
world, and it is recommended for users by CRAA (China Refrigeration And Air-Conditioner Industry Association).
As room AC, It is widely used in hotel, showplace, marketplace, office room, etc.; as industrial AC, it can
meet the requirement of electron, chemical plant, medical treatment, pharmacy, tobacco produce, food
produce, etc.
63 64
HOW TO READ THE MODELS ?Air Handling Unit
M K W1 - 040 W A - 1 Z 3 / M
Midea
W1: Single-wall air handling unitW2: Duble-wall air handling unit
Nominal airflow volume (x100m3/h)
Structure form of the unitW: horizontal type
Direction of pipe connectionZ: Left connectionY: Right connection
Supply air direction: type 1
K series Air Handling Unit
Design sequence code
Drawing off method of filter3: up draw off
Coil row quantity A: 4 rowsB: 6 rowsC: 8 rows
M K A - 300
Midea
A: Four way cassette typeB: Compact four way cassetteC: One way cassetteF1: Concealed floor standingF2: Expoded floor standing
Nominal airflow volume (CFM)
K series Fan Coil Unit
Fan Coil Unit
Air Handling Unit Fan Coil Unit
65 66
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKC-3003005003035513053010.133
850x235x4001080x310x460
2337
MKC-4004006303790642565314.533
850x235x4001080x310x460
2337
MKC-600600100057099660100527.135
1200x198x6551380x265x775
3138
One way cassette
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKA-60060010005709966010053835
840x310x9301020x330x930
3646
MKA-7507501250698511550120425.235
840x310x9301020x330x930
3646
MKA-850850140078601364013822738
840x310x9301020x330x930
3646
MKA-950950160089101501115413038
840x310x9301020x330x930
3646
MKA-120012002000112501906519284439
840x310x9301020x330x930
3646
MKA-150015002500139562282023884639
840x310x9301020x330x930
3646
Four way cassette
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKB-3003005003035513053010.133
580x245x580750x340x750
2130
MKB-4004006303790642565314.533
580x245x580750x340x750
2130
MKB-4504507104350648074018.334
580x245x580750x340x750
2130
MKB-5005008004835821085027.135
580x245x580750x340x750
2130
Four way cassette(compact)
Single wall vertical type AHU
Air handle volume: 2000~20000m3/h
Cooling capacity: 12~345kW
Heating capacity: 18~370kW
Dual wall horizontal type
Air handle volume: 2000~60000m3/h
Cooling capacity: 12~985kW
Heating capacity: 18~1100kW
Dual wall vertical type
Air handle volume: 2000~60000m3/h
Cooling capacity: 12~985kW
Heating capacity: 18~1100kW
Wall-mounted type
Air handle volume: 1500~5000m3/h
Cooling capacity: 6~260kW
Heating capacity: 11~290kW
Single wall horizontal type
Air handle volume: 2000~20000m3/h
Cooling capacity: 12~345kW
Heating capacity: 18~370kW
Fan Coil Unit
67 68
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKT-3003005003035513053010.133
808x240x4891110x340x570
2130
MKT-4504507104350648074018.334
808x240x4891110x340x570
2130
MKT-5005008004835821085027.135
1108x240x4891410x340x570
2130
MKT-60060010005790966010053835
1108x240x4891410x340x570
2130
MKT-4004006303790642565314.533
808x240x4891110x340x570
2130
Duct type
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKF1-150150250180020003756.333
550x212x545635x265x630
3034
MKF1-3003005002200260053010.135
750x212x545835x265x630
3539
MKF1-4004006802800320065314.535
750x212x545835x265x630
3539
MKF1-4504507603600400074018.335
950x212x5451035x265x630
3944
MKF1-250250425200024004208.234
550x212x545635x265x630
3034
Concealed floor standing
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKF2-150150250180020003756.333
880x225x6261025x285x810
3337
MKF2-3003005002200260053010.135
1000x225x6261145x285x810
3842
MKF2-4004006802800320065314.535
1000x225x6261145x285x810
3842
MKF2-4504507603600400074018.335
1200x225x6261335x285x610
4347
MKF2-250250425200024004208.234
880x225x6261025x285x810
3337
Exposed floor standing
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKT-7507501250698511550120425.235
1308x240x4891590x340x570
3438
MKT-850850140078601364013822738
1308x240x4891590x340x570
3438
MKT-950950160089101501115413038
1308x240x4891590x340x570
3438
MKT-120012002000112501906519284439
1573x240x4892130x340x570
4752
MKT-150015002500139562282023884639
1573x240x4892130x340x570
45055
MKT-200020003400189002835028484042
1599x367x6051613x381x619
4753
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKF1-5005008504500500027.13437
950x212x5451035x265x630
3944
MKF1-600600100056006300383539
1250x212x5451335x265x630
5055
MKF1-800800135071008000453840
1250x212x5451335x265x630
5055
MKF1-10001000170080009000603942
1250x212x5451335x265x630
5055
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Model
Air volume
Cooling CapacityHeating CapacityWater flowWater resistanceNoise levelNet dimensionPacking dimensionNet weightGross weight
CFMm3/hWWLPHkPadB(A)mm(WxHxD)mm(WxHxD)kgkg
MKF2-5005008504500500027.13437
1200x225x6261335x285x810
4347
MKF2-600600100056006300383539
1500x225x6261645x285x810
5560
MKF2-800800135071008000453840
1500x225x6261645x285x810
5560
MKF2-10001000170080009000603942
1500x225x6261645x285x810
5560
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Accessories
Accessories
Accessorial electric heater
SDS SeriesProduction feature
Adopt high efficiency electric heater, symmetrically heat;
It is tested under 10bar water pressure, high security;
Small body with high removability, easy for load;
It can be customized just according to customer's requirement.
A
B C D
E
C
D
E
SDS-15/S-A
SDS-18/S-A
SDS-27/S-A
SDS-30/S-A
SDS-45/S-A
SDS-54/S-A
SDS-60/S-A
SDS-72/S-A
SDS-75/S-A
SDS-90/S-A
SDS-100/S-A
SDS-120/S-A
SDS-144/S-A
SDS-150/S-A
SDS-175/S-A
SDS-180/S-A
SDS-200/S-A
ModelDimension (mm)
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
15KW
18KW
27KW
30KW
45KW
54KW
60KW
72KW
75KW
90KW
100KW
120KW
144KW
150KW
175KW
180KW
200KW
A
960
960
1260
1260
1160
1360
1360
1200
1200
1360
1520
1660
1960
1960
1660
1660
1960
B
350
350
350
350
400
450
450
480
480
530
530
600
600
600
650
650
650
C
280
280
280
280
335
390
390
390
390
440
440
492
540
540
598
598
598
D
159
159
203
203
219
245
245
273
273
325
325
426
426
426
480
480
480
E
130
130
180
180
180
220
220
240
240
240
240
240
240
240
280
280
280
Remark: The accessorial electric heater should be additional ordered.
Voltage(V) Input(kW)
70
Accessories
71
SDH SeriesProduction feature
Stainless steel structure, and filled in insulating material
between the shell and electric heat pipe, and also has high
anti-erode capability.
Adopt famous temperature controller can avoid destroy the
components.
Adopt high efficiency electric heater, symmetrically heat.
Cover
Waterproof cover Water outlet
Shell
Water inletElectric heater pipe
Inner flue
Heat preservation layer
Wire outlet Fixed holeDrainage valve
SDH-2-A
SDH-3-A
SDH-4-A
SDH-5-A
SDH-6-A
SDH-7/S-A
SDH-8/S-A
SDH-9/S-A
SDH-10/S-A
SDH-12/S-A
SDH-15/S-A
SDH-20/S-A
Model
220/380
220/380
220/380
220/380
220/380
380
380
380
380
380
380
380
2kW
3kW
4kW
5kW
6kW
7kW
8kW
9kW
10kW
12kW
15kW
20kW
350
350
400
400
450
450
410
410
510
510
560
560
*158mm 1.25''
*190mm 1.5''
Voltage (V) Input (kW)Total
length(mm) Diameter(mm) Water inlet/outlet
Remark: The accessorial electric heater should be additional ordered.