AREA CALCULATIONS -ENITRE HOUSE
HEATED & COOLED OF:
FIRST FLOOR LIVING:GARAGE:
FRONT PORCH:BACK PORCH:
TOTAL OF:
HEATED & COOLED OB:
2934 SF
2934 SF628 SF00 SF224 SF
3786 SF
3046 SF
FLOOR PLAN NOTES:
1. THE CONTRACTOR AND SUBCONTRACTOR(S) SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH THE CONTRACT DOCUMENTS AND SHALL IMMEDIATELY REPORT ALL QUESTIONABLE CONDITIONS TO THE DESIGNER BEFORE STARTING THE WORK.
2. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
3. COORDINATE ALL PORTIONS OF THE WORK.4. DIMENSIONS SHOWN ON FLOOR PLAN ARE STUD DIMENSIONS - FROM FACE
OF STUD TO FACE OF STUDE UNLESS OTHERWISE NOTED.5. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE WINDOW
FOR EMERGENCY EGRESS. ALL EGRESS WINDOWS TO MEET LOCAL CODES AND REGULATIONS.
6. PROVIDE SAFETY GLASS IN ALL THE FOLLOWING LOCATIONS: ANY BATHROOM WINDOWS WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 60" ABOVE THE F.F.E., ALL STAIR CASES, ALL WINDOWS WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 12" ABOVE THE F.F.E., AND ALL EXTERIOR DOORS WITH GLAZING.
7. WINDOWS TO BE SCREWED AND INSTALLED TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
8. ALL BOTTOM PLATES, INTERIOR AND EXTERIOR, TO BE TREATED LUMBER.9. WALLS LESS THAN 5' TO PROPERTY LINE ARE REQUIRED TO HAVE A ONE
HOUR FIRE RATING. 10. BATHROOM EXHAUST FANS SHOULD BE TERMINATED AT LEAST 10" ABOVE
INSULATION OR VENTED THROUGH ROOF IF SPRAY FOAM IS USED. 11. SHOWER WALLS MUST USE CEMENT BACKER BOARD WHEN TILE IS
INSTALLED.
A4' - 0"L=
B1' - 8"L=
BRACED WALL PANEL
ALTERNATE BRACED WALL PANEL
LAMINATED BEAM
SEE WALL BRACING DETAILS ON SHEET A3
WALL PANEL BRACING
9' x7' OH DR
9' x7' OH DR
(2) 2068
3060 SH
GARAGE15' - 0" X 24' - 0"9' FLAT CEILING GARAGE
15' - 0" X 24' - 0"9' FLAT CEILING
GREAT ROOM15' - 2" X 21' - 0"
9' CLGLVP FLOOR
BDRM #211' - 10" X 9' - 5"9' FLAT CEILING
CARPET
BATH9' CLGLVP
BDRM #312' - 0" X 10' - 4"VAULTED CLG
CARPET
MASTER BEDRM12' - 0" X 13' - 2"VAULTED CEILING
CARPET
WIC
BATH9' CEILING
LVP FLOOR
KITCHEN & DININGAREA
13' - 10" X 21' - 0"CATHEDRAL CEILING
LVP FLOOR
ATTIC STAIR LOCATION TBD ON SITE
ATTIC STAIR LOCATION TBD ON SITE
3060 SH 2860 SH 2860 SH
3080 BN DR
2868
3050 3050
3068
2468
FR
IDG
E
LAMINATED BEAM
LAMINATED BEAM
1HR FIRE WALL, RE: 2/A1 and 3/A1
WIC
20
68
2850
SH
DW
SEATSEAT
GREAT ROOM15' - 2" X 21' - 0"
9' CLGLVP FLOOR
KITCHEN & DININGAREA
13' - 10" X 21' - 0"CATHEDRAL CLG
LVP FLOOR
MASTER BEDRM12' - 0" X 13' - 2"VAULTED CLG
CARPET
BATH9' CLG
LVP FLOOR
WIC WIC
30
68
FR
IDG
E
2868
3068
3080 BN DR
PANTR
Y
2868
(2) 2068
2868
2868
2868
2850
SH
3050 3050
3068
2850
SH
PANTR
Y
24683068
30
68
2868
5FT
FIB
ER
GLASS
2868
2868
2868
(2) 2068
(2) 2068
BEDRM #211' - 10" X 9' - 5"
9' CLGCARPET
BEDRM #312' - 0" X 10' - 4"CATHEDRAL CLG
CARPET
BATH9' CLGLVP
3'X7' C/O 3'X7' C/O
20
70
C/O
20
70
C/O
20
70
C/O
20
70
C/O
5FT
FIB
ER
GLASS
2850
SH
BACK PORCH
9' CLGBACK PORCH
9' CLG
0' - 3 1/2"
3' - 5" 7' - 5" 3' - 5 1/8"
0' - 7 5/8"
3' - 5" 7' - 4 1/2" 3' - 4 1/2"
29' - 4 1/4"
13' -
5 1
/2"
4' -
5 1
/2"
6' -
3 1
/2"
0' -
3 1
/2"
17' - 0 1/2"
10' -
9 1
/2"
2' -
7"
9' -
9 1
/2"
3' -
6"
24' -
9"
24' -
2 1
/2"
0' -
3 1
/2"
75' -
11"
3' - 8 1/2" 12' - 3 1/2" 14' - 0 1/4" 13' - 3 1/2" 12' - 4" 3' - 8 1/2"0' - 3 1/2"
59' - 7 3/4"
6' -
3 1
/2"
4' -
5 1
/2"
13' -
5 1
/2"
24' -
9"
3' -
6"
9' -
9 1
/2"
2' -
7"
10' -
9 1
/2"
0' -
3 1
/2"
0' - 3 1/2" 15' - 1 1/2" 29' - 0 3/4" 15' - 2"
7' -
11 1
/2"
1' -
10
"2' -
3"
22' -
6"
3' - 3 1/2" 3' - 8" 5' - 7 1/2" 4' - 5"
2' -
10"
10' -
7 1
/2"
2' -
6 1
/2"
10' -
11"
4' - 1 1/2" 5' - 8" 3' - 8" 3' - 7"
5' - 0 1/2" 4' - 1 1/2" 3' - 1 1/2"
3' - 6 1/2"
3' - 2" 4' - 1 1/2" 5' - 1 1/8"
3' - 6 1/2"
5' -
3 1
/2"
4' - 3 1/2" 7' - 10 1/2" 3' - 10" 3' - 4" 10' - 0 5/8"
8' -
9 1
/2"
7' -
9"
6' - 0" 6' - 2" 3' - 10"
2' - 3 1/2"
5' -
2 1
1/16
"21' -
4"
A4' - 0"
L=
A4' - 0" L=
A4' - 0"
L=
A4'
- 0"
L=
A4' - 0" L=
A4'
- 0"
L=A
4' -
0"L=
A4'
- 0"
L=
A4'
- 0"
L=
A4'
- 0"
L=
A4' - 0"L=
A4' - 0"L=
A4' - 0"L=
A4' - 0"
L=
A4' - 0"
L=
A4' - 0"
L=A
4' - 0"L=
A4' - 0"
L=
A4' - 0" L=
B1' - 8" L=
B1' - 8" L= B1' - 8" L=
B1' - 8" L=
3080 BN DR
3' - 10"
3080 BN DR
3' - 1"
20
68
3' - 1"
AREA CALCULATIONS -EACH SIDE
HEATED & COOLED OF:
FIRST FLOOR LIVING:GARAGE:
FRONT PORCH:BACK PORCH:
TOTAL OF:
HEATED & COOLED OB:
1467 SF
1467 SF314 SF00 SF112 SF
1893 SF
1523 SF
1/2" GYP. BOARD
2X4 STUD @16" O.C., STAGGER STUDSR22 INSULATION TO FILL CAVITY
1/2" GYP. BOARD
R22 INSULATION TO FILL CAVITY
NO PENETRATIONS THRU FIRE WALL ALLOWED
*FIRE WALL SHOULD RUN VERTICALLY FROM f.f.E. UP TO ROOF DECK
0' - 0 5/8"
0' - 3 1/2"
0' - 0 5/8"
5/8" TYPE X GYP. BD. EACH SIDE
1/2" GYP. BOARD
R22 INSULATION TO FILL CAVITY
1/2" GYP. BOARD
R22 INSULATION TO FILL CAVITY
NO PENETRATIONS THRU FIRE WALL ALLOWED
0' - 0 5/8"
0' - 3 1/2"
0' - 0 5/8"
5/8" TYPE X GYP. BD. EACH SIDE
5/8" TYPE X GYP. BD. EACH SIDE UP TO ROOF DECK
NO PENETRATIONS THRU FIRE WALL ALLOWED
CEILING JOIST
AT
TS
XETE FO
SA
REG
IS
TERED ARCHITEC
TWAHS
ARB
RAAS
D
55 82
M.
2
DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM
CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464
806.777.0421
DATE:
DR
AW
ING
S P
RE
PA
RE
D B
Y:
SA
RA
@C
LE
AR
VIE
WC
US
TO
MH
OM
ES
.CO
M
MA
ILIN
G A
DD
RE
SS
:P
O B
OX
64
75
6
LU
BB
OC
K,
TX
79
46
4
SA
RA
BR
AD
SH
AW
, AIA
OF
FIC
E A
DD
RE
SS
:1
05
07
QU
AK
ER
AV
E.
SU
ITE
10
1L
UB
BO
CK
, T
X 7
94
23
PH
ON
E:
80
6.4
45
.12
55
A1FLOOR PLAN
07-10-17
SP
EC
DU
PLE
XS
TO
NE
BR
IDG
E -
LO
T #
124
2026
102
ND
ST
RE
ET
LUB
BO
CK
, TX
SIGNED:07-10-17
DUPLEX
1/4" = 1'-0"1
FLOOR PLAN
1" = 1'-0"2
DUPLEX 1HR FIRE WALL - PLANDETAIL
1" = 1'-0"3
DUPLEX 1HR FIRE WALL - SECTIONDETAIL
No. Revision Date1 Revision 1 Date 1
F.F.E.0' - 0"
10' PLATE HIEGHT10' - 0"
9' PLATE HIEGHT9' - 0"
2860 SH 2860 SH3060 SH3060 SH 9' x7' OH DR 9' x7' OH DR
COMPOSITE SHINGLE
BRICK
BRICK
6"
12"
CEDAR HEADER
CEDAR HEADER
8"
12"
8"
12"
6"
12"6"
12"
3068 2850 SH2850 SH
6"
12"
30682850 SH 2850 SH
6"
12"
COMPOSITE SHINGLE
BRICK
306830503050 3050 30503068
COMPOSITE SHINGLE
BRICK
6"
12"
AT
TS
XETE FO
SA
REG
IS
TERED ARCHITEC
TWAHS
ARB
RAAS
D
55 82
M.
2
DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM
CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464
806.777.0421
DATE:
DR
AW
ING
S P
RE
PA
RE
D B
Y:
SA
RA
@C
LE
AR
VIE
WC
US
TO
MH
OM
ES
.CO
M
MA
ILIN
G A
DD
RE
SS
:P
O B
OX
64
75
6
LU
BB
OC
K,
TX
79
46
4
SA
RA
BR
AD
SH
AW
, AIA
OF
FIC
E A
DD
RE
SS
:1
05
07
QU
AK
ER
AV
E.
SU
ITE
10
1L
UB
BO
CK
, T
X 7
94
23
PH
ON
E:
80
6.4
45
.12
55
A2ELEVATIONS
07-10-17
SP
EC
DU
PLE
XS
TO
NE
BR
IDG
E -
LO
T #
124
2026
102
ND
ST
RE
ET
LUB
BO
CK
, TX
SIGNED:07-10-17
DUPLEX
1/4" = 1'-0"1
FRONT - NORTH
3/16" = 1'-0"2
LEFT - EAST
3/16" = 1'-0"3
RIGHT - WEST
3/16" = 1'-0"4
BACK - SOUTH
No. Revision Date
CRICKET DIMENSIONS
ROOF SLOPE H
12 - 12 1/2 OF W
8 - 12 1/3 OF W
6 - 12 1/4 OF W
4 - 12 1/6 OF W
3 - 12 1/8 OF W
H
ROOF LINE
1" M
IN. AIR
SPAC
E
W
FLUE LINERPLAN VIEW
ELEVATION VIEW
CLR
.0
' -
2"
MIN.
1' - 4"
INTERIOR LOAD BEARING WALL
MIN
.
1' -
0"
CONCRETE SLAB-ON-GRADE PER CITY OF LUBBOCK REQUIREMENTS
#3 TIES @ 32" O.C.
COMPACTED FILL
6 MIL VAPOR RETARDER, OVERLAP 6" AND TAPE PER MFR. RECOMENDATION
2-#4 BARS CONT. SET ON REBAR CHAIRS
UNIFORMED CONTINUOUS FOOTING
CLR.0' - 3"
MIN.
1' - 4"
FOR ONE AND TWO-STORY CONSTRUCTION
2X FRAMING AS REQUIRED
GARAGE DOOR OPENING
SLO
PE
MIN.
1' - 0"
FACE BRICK
CONCRETE CURB
FOOTING SHALL BE CONTINUOUS AT GARAGE DOOR OPENING
9
A3
Sim
0' - 5 1/2"
MIN
.
1' -
0"
MIN.
1' - 4"
STUD LINE
CLR
.0
' -
3"
CONTINUOUS FOOTING BEYOND (REINFORCEING CONTINUOUS THROUGH SPREAD FOOTING)
MIN
.
2' -
0"
4-#4 BARS EACH WAY
COMPACTED FILL
(X VARIES)
2' - 6"
0' -
4"
0' - 2"
CHAMFER OR TOOLED EDGE
EXPANSION JOINT FILLER MATERIAL WITH CAULKING
#3 U-SHAPED DOWELS @ 32" O.C.
SLOPE
6"
6"#3 BAR CONT.
CLR
.0
' -
2"
0' - 5 1/2"
MIN
.
1' -
0"
MIN.
1' - 4"
MIN.
0' - 8"
8" MIN.
INSULATION
STUD LINE
FACE BRICK WITH BRICK TIES @ 24" O.C. MAX EACH WAY (BRICK TIES TO SUPPORT NO MORE THAN 2.67 SQUARE FEET OF BRICK AREA
BUILDING WRAP
THROUGH WALL FLASHING
MORTAR NET
WEEP HOLES @ 33" O.C. MAX
FILL GRAVITY WITH GROUT
CLR
.0
' -
3"
CLR.0' - 3"
UNIFORM CONTINUOUS FOOTING
MIN
.
2' -
0"
LAP SHEATHING OVER JOINT
CONCRETE SLAB-ON-GRADE PER CITY OF LUBBOCK REQUIREMENTS
#3 TIES @ 24" O.C.
2-#4 BARS CONT. TOP AND BOTTOM (LAP 18" AT SPLICES)
6 MIL VAPOR RETARDER
COMPACTED FILL
10"
10"
2' - 6"
1' - 0"1' - 0"1' -
0"
0' -
4"
MINIMUM (3) #4 BARS
#4 BARS @ 16" O.C.
CONT. REINF. IN SHELTER WALLS PER PLAN DETAIL
ALTERNATE DIRECTION ON EVERY OTHER BENT #4 BAR
CONCRETE FLOOR SLAB
2'-8"
N.T
.S.
FURRING STRIPS AND INTERIOR FINISHES (TYP.)
MAX DOOR SIZE 3'-0", MAY SWING IN OR OUT
6" CMU MIN.
#4 VERTICAL BAR IN EACH CELL
GROUT ALL CELLS SOLID
REINFORCE BOND BEAM ABOVE DOOR W/(2) #4 HORIZONTAL BARS
10 GA. METAL DOOR FRAME
TEE ANCHOR (4) PER JAMB
GROUT SOLID
AT
TS
XETE FO
SA
REG
IS
TERED ARCHITEC
TWAHS
ARB
RAAS
D
55 82
M.
2
DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM
CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464
806.777.0421
DATE:
DR
AW
ING
S P
RE
PA
RE
D B
Y:
SA
RA
@C
LE
AR
VIE
WC
US
TO
MH
OM
ES
.CO
M
MA
ILIN
G A
DD
RE
SS
:P
O B
OX
64
75
6
LU
BB
OC
K,
TX
79
46
4
SA
RA
BR
AD
SH
AW
, AIA
OF
FIC
E A
DD
RE
SS
:1
05
07
QU
AK
ER
AV
E.
SU
ITE
10
1L
UB
BO
CK
, T
X 7
94
23
PH
ON
E:
80
6.4
45
.12
55
A3DETAILS
07-10-17
SP
EC
DU
PLE
XS
TO
NE
BR
IDG
E -
LO
T #
124
2026
102
ND
ST
RE
ET
LUB
BO
CK
, TX
SIGNED:07-10-17
DUPLEX
1/4" = 1'-0"1
BRACED WALL PANEL - A 1/4" = 1'-0"
2BRACED WALL PANEL - B
1/4" = 1'-0"3
BRACED WALL PANEL - C 1/4" = 1'-0"
4BRACED WALL PANEL - D
1/2" = 1'-0"5
IRC WALL BRACING PROVISIONS
1 1/2" = 1'-0"6
CRICKET DIMENSIONS
3/4" = 1'-0"7
FOOTING - INTERIOR LOADBEARING WALL
3/4" = 1'-0"8
FOOTING - SPOT FOOTING ATGARAGE DOOR CORNER - PLAN
3/4" = 1'-0"9
FOOTING - SPOT FOOTING ATGARAGE DOOR CORNER -SECTION
3/4" = 1'-0"10
FOOTING - TYPICAL TWO POUREXTERIOR FOOTING
3/4" = 1'-0"11
SAFEROOM DETAIL - FOOTING 3/4" = 1'-0"
12SAFEROOM DETAIL - PLAN
No. Revision Date
GFI
WP
TV
M
W
G
WH
WD WHW
D
TV
TV
TV
TV
TV
TV
TV
TV
ELECTRICAL NOTES:
1. ELECTRICAL COMPONENTS & EQUIPMENT SHALL MEET OR EXCEED ALL N.E.C. AND LOCAL CODES.
2. INSTALLATIONS SHALL COMPLY WITH ALL ENTITIES HAVING JURISDICTION.3. CONTRACTOR SHALL OBTAIN OWNER APPROVAL FOR ALL FIXTURE
SELECTIONS AND LOCATIONS.4. VERIFY APPLIANCE AND EQUIPMENT ELECTRICAL REQUIREMENTS.5. VERIFY SECURITY SYSTEM & INTERCOM W/BUILDER.6. VERIFY CABLE/DATA/TELEVISION JACK LOCATIONS PRIOR TO
INSTALLATION. 7. VERIFY ALL FLOOR OUTLETS AS PER OWNER.8. VERIFY ALL LIGHTING IN KITCHEN, BREAKFAST, & LIVING ROOM.9. VERIFY ALL STEREO, INTERCOM, & COMPUTER WIRERING AS PER OWNER.10. VERIFY ALL OUTLETS ON EXTERIOR OF HOUSE.11. ALL EXTERIOR ELECTRICAL OUTLETS/FIXTURES TO BE WEATHER PROOF. 12. VERIFY ALL OUTLETS IN SOFFITS. 13. VERIFY ALL EXTERIOR TREE LIGHING & LANDSCAPE LIGHTING.14. PROVIDED LIGHTING THROUGHOUT ATTIC.15. VERIFY ELECTRICAL FOR ATTIC FANS.16. FIELD VERIFY LOCATION OF POWER TO BE BROUGHT TO HOUSE.17. ELECTRICAL AND LIGHTING LAYOUT IS REFERENCE ONLY. FINAL LAYOUT
TO BE VERIFIED BY CONTRACTOR PRIOR TO PERFORMING WORK.
SPOT LIGHT
2 LIGHT FLUORESCENT
CHANDELIER
FAN
CEILING MOUNTED FIXTURE
RECESSED CAN
VANITY LIGHT
110 OUTLET
220 OUTLET
HOSE BIB
FLOOR OUTLET
4 LIGHT FLUORESCENT
110 OUTLET - GROUND FAULT INTERUPT
110 OUTLET - WATER PROOF
HEAT/VENT/LIGHT COMBINATION
VENT/LIGHT COMBINATION
TELEPHONE JACK
TV/DATA JACK
SPOT LIGHT MOTION ACTIVATED
WALL SWITCH
SHOWER FIXTURE
THERMOSTAT
DOORBELL CHIME
PRE-WIRE GARAGE DOOR OPENER
WALL MOUNTED FIXTURE
WALL WASH RECESSED CAN
GAS BARB
ELECTRCAL LEGEND
ELECTRICAL SPECIFICATIONS:
1. PROVIDE UPLIGHTING ON TIMER IN GARAGE2. PROVIDE EAVE OUTLETS ON TIMER IN GARAGE3. PROVIDED UPLIGHTING AS PER CLEARVIEW SPECS
AT
TS
XETE FO
SA
REG
IS
TERED ARCHITEC
TWAHS
ARB
RAAS
D
55 82
M.
2
DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM
CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464
806.777.0421
DATE:
DR
AW
ING
S P
RE
PA
RE
D B
Y:
SA
RA
@C
LE
AR
VIE
WC
US
TO
MH
OM
ES
.CO
M
MA
ILIN
G A
DD
RE
SS
:P
O B
OX
64
75
6
LU
BB
OC
K,
TX
79
46
4
SA
RA
BR
AD
SH
AW
, AIA
OF
FIC
E A
DD
RE
SS
:1
05
07
QU
AK
ER
AV
E.
SU
ITE
10
1L
UB
BO
CK
, T
X 7
94
23
PH
ON
E:
80
6.4
45
.12
55
E1ELECTRICAL
PLAN
07-10-17
SP
EC
DU
PLE
XS
TO
NE
BR
IDG
E -
LO
T #
124
2026
102
ND
ST
RE
ET
LUB
BO
CK
, TX
SIGNED:07-10-17
DUPLEX
1/4" = 1'-0"1
ELECTRICAL PLAN
No. Revision Date
WH
WD WHW
D
FOOTING NOTES:
FOLLOWING ARE ADDITIONAL COMMENT TO BUILDERS AS A REMINDER TO CONSIDER WHEN SELECTING FOUNDATION DETAILS:
1. ON LOTS THAT REQUIRE MORE THAN TWO FEET OF FILL AT ANY POINT, CHECK WITH THE INSPECTION DEPARTMENT FOR DIRECTION AS TO NEEDS FOR ENGINEERED FOUNDATION DETAILS.
2. REQUIREMENT OF SAND FILL3. REQUIREMENT OF VAPOR RETARDER4. REQUIREMENT OF PROPER FILL MATERIAL AND COMPACTION OF ALL
TRENCHES IN FOUNDATION.5. CONSIDER WHERE CONCENTRATED LOAD POINTS WILL OCCUR AND
CONSIDER ADDITIONAL CONCRETE SUPPORT AT THOSE LOCATIONS.6. ADJUST FOOTINGS AT ZERO LOT LINES NOT TO ENCROACH ON
ADJACENT LOT.7. CONSIDER FOOTINGS AND FOUNDATION DETAILS AT BASEMENT
LOCATIONS AND IT'S IMPACT ON MAIN FLOOR FOUNDATION ABOVE.8. NOTE REQUIREMENTS FOR TERMITE TREATMENT9. BUILDER SHOULD BE KNOWLEDGEABLE ABOUT EXISTING NATURAL
SOILS, INFORMATION FROM DEVELOPER OR PERFORM TEST TO DETERMINE SOILS INFORMATION PRIOR TO CONSTRUCTION ON LOT.
FR
IDG
E
FR
IDG
E
DW
DW
5FT
FIB
ER
GLASS
5FT
FIB
ER
GLASS
RECESSFLOOR 4" RECESS
FLOOR 4"
3' - 8 1/2" 12' - 7" 13' - 8 3/4" 13' - 3 1/2" 12' - 7 1/2" 3' - 8 1/2"
59' - 7 3/4"
10' -
9 1
/2"
40
' -
11"
13' -
2"
11' -
0 1
/2"
75' -
11"
15' - 1 1/2" 29' - 4 1/4" 15' - 2"
11' -
0 1
/2"
13' -
2"
40
' -
11"
10' -
9 1
/2"
1' - 10 1/2"
17' - 0"
1' - 10 1/2"
17' - 0 1/2"
4' -
6 1
3/16
"
1' -
6"
3' -
0 1
3/16
"
13' - 0 1/2" 0' - 11 3/4" 13' - 0"
18' -
3 1
/2"
19' -
9 1
/2"
9' - 3"
9' - 3"
5' - 11 1/4"
17' -
11 1
/4"
18' -
10 1
/2"
21' -
3 1
/2"
4' - 5 1/4"
12' - 3 3/4"
8' -
4 1
5/16
"
4' -
7"
2' -
5"
10' -
2 1
/4" 15
' -
4 1
/4"
15' -
11"
12' -
11 1
/4"
2' -
5 1
/4"
22' - 4 3/16" 7' - 1 5/16"
4' -
7 1
/4"
1' - 10"
3' - 7 1/2" 3' - 5"
5' - 6"
5' - 6 1/2" 3' - 5 1/2" 3' - 8 1/4"
1' - 10 1/4"
4' - 5 1/4"
12' - 3 3/4"
17' -
11 1
/4"
5' - 11 1/4"
6' -
9 1
1/16
"
19' -
7 1
/2"
8' -
4 1
5/16
"
3' - 1 3/4"
2' -
5"
4' -
7"
6' -
0"
16' - 10 1/4" 16' - 10 3/4"
6' -
0"
SLOPE AS PER SPEC SLOPE AS PER SPEC
96' - 6
1/2"
RECESSFLOOR 4"
RECESSFLOOR 4"
3' - 1"
6' -
0"
3' - 1 1/2"
6' -
0"
AT
TS
XETE FO
SA
REG
IS
TERED ARCHITEC
TWAHS
ARB
RAAS
D
55 82
M.
2
DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM
CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464
806.777.0421
DATE:
DR
AW
ING
S P
RE
PA
RE
D B
Y:
SA
RA
@C
LE
AR
VIE
WC
US
TO
MH
OM
ES
.CO
M
MA
ILIN
G A
DD
RE
SS
:P
O B
OX
64
75
6
LU
BB
OC
K,
TX
79
46
4
SA
RA
BR
AD
SH
AW
, AIA
OF
FIC
E A
DD
RE
SS
:1
05
07
QU
AK
ER
AV
E.
SU
ITE
10
1L
UB
BO
CK
, T
X 7
94
23
PH
ON
E:
80
6.4
45
.12
55
F1FOUNDATION
PLAN
07-10-17
SP
EC
DU
PLE
XS
TO
NE
BR
IDG
E -
LO
T #
124
2026
102
ND
ST
RE
ET
LUB
BO
CK
, TX
SIGNED:07-10-17
DUPLEX
1/4" = 1'-0"1
FOUNDATION PLAN
No. Revision Date
25' FR
ONT S
ETB
ACK
5' SIDE SETBACK
5' SIDE SETBACK
6" / 12"
6" / 1
2"
6" / 12"
6" / 12"
6" / 12"
8" / 12"
6" / 1
2"
6" / 1
2"
6" / 12"
6" / 1
2"
6" / 1
2"
DR
IVEW
AY
15' R
EAR
SETB
ACK
FENCE L
INE
36' -
0"
SID
EW
ALK T
O M
ATCH E
XIS
TIN
G
8" / 1
2"
8" / 1
2"
8" / 12"
6" / 12"
6" / 1
2"
6" / 1
2"
60
' -
5 3
/4"
30
' -
2 1
/4"
13' - 10 3/16"
18' - 0"
123.48
71.57
114.40
70
.49
5.0
0
5.0
0
15.00
13.85
23.80
6" / 1
2"
AT
TS
XETE FO
SA
REG
IS
TERED ARCHITEC
TWAHS
ARB
RAAS
D
55 82
M.
2
DO NOT REPRODUCE WITHOUT WRITTEN PERMISSION FROM
CLEARVIEW CUSTOM HOMES, LLC.PO BOX 64756 LUBBOCK TX 79464
806.777.0421
DATE:
DR
AW
ING
S P
RE
PA
RE
D B
Y:
SA
RA
@C
LE
AR
VIE
WC
US
TO
MH
OM
ES
.CO
M
MA
ILIN
G A
DD
RE
SS
:P
O B
OX
64
75
6
LU
BB
OC
K,
TX
79
46
4
SA
RA
BR
AD
SH
AW
, AIA
OF
FIC
E A
DD
RE
SS
:1
05
07
QU
AK
ER
AV
E.
SU
ITE
10
1L
UB
BO
CK
, T
X 7
94
23
PH
ON
E:
80
6.4
45
.12
55
S1SITE PLAN
07-10-17
SP
EC
DU
PLE
XS
TO
NE
BR
IDG
E -
LO
T #
124
2026
102
ND
ST
RE
ET
LUB
BO
CK
, TX
SIGNED:07-10-17
DUPLEX
3/16
" =
1'-0
"1
SIT
E P
LAN
No. Revision Date
top related