daq status for cosmic-ray test in ral

Post on 08-Jan-2016

44 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

DAQ Status for cosmic-ray test in RAL. Contents Status Setup for cosmic-ray test bench Schedule. Hideyuki Sakamoto MICE Phone meeting 12 th July 2007. Scheme for DAQ. DATE (Data Acquisition and Test Environment) framework. Need to build modified readout program for MICE in DATE. - PowerPoint PPT Presentation

TRANSCRIPT

DAQ Status for cosmic-ray test in RAL

Hideyuki Sakamoto

MICE Phone meeting

12th July 2007

Contents• Status• Setup for cosmic-ray test bench • Schedule

Scheme for DAQ

• DATE (Data Acquisition and Test Environment) framework.

• Need to build modified readout program for MICE in DATE.– Other part (e.g. data format, eventBuilding) will use default one.

– Readout program is prepared for each modules.• VLSB module made by FNAL

• TDC/ADC module made by CAEN

• Sub-framework (readout+initializing) is under preparing by James.

Status

• New RHB is coming today, taking data with test charge injection/cosmic-ray.– Threshold: 100,120,160,200,240– Bias ON & Heater ON– Try heater current to be low by heating cryostat with OXFORD temperature controller.

• Started working on DATE from last week.– Yesterday, once success to starting readout program in DATE.

…fail at 2nd try…– Should be finished in next week at RAL.

• Readout code is under implementing.– Sub-framework is almost done?– Command lists are replaced from AFEII to AFEIIt.

– Can be tested at stand alone.– Linux driver for SBS(bit3) dataBLIZZARD to test in Imperial.– In next week, test will also be done in RAL.. (using CAEN)

Threshold 100It seems LHB RHB compared with previous version for Excel sheet.

Threshold 120Increase noise

Threshold 160Increase noise

Threshold 200Decrease noise

Threshold 240Decrease/Same? noise

Bias ON - threshold 160 - w/o charge injection

test_pulse_033_old-excel_thre160_heater_on_bias_on

OLD version (afeIIt_vlsb_daq_810.c.xls) Previous RHB

Bias ON - threshold 200 - w/o charge injection

test_pulse_032_old-excel_thre200_heater_on_bias_on

OLD version (afeIIt_vlsb_daq_810.c.xls) Previous RHB

Bias ON - threshold 240 - w/o charge injection

test_pulse_031_old-excel_thre240_heater_on_bias_on

OLD version (afeIIt_vlsb_daq_810.c.xls) Previous RHB

Comment for today’s result

• Noise rate seems to be reproduced as previous RHB.

• Noise rate seems to be reversed at threshold 160 by eye.– This may not true.

• For treatment of heater current, it is better to compare with the same RHB, so taking data with default setting with this new RHB.

Possible reason for RHB noise

• Remember that we do not see ANY noise with test charge injection data.

• Let’s check this fact by taking data as changing triggering rate.– This will be done by LED pulse injection.

– If we take data with high rate, we cannot not see any noise as LED data.

– It not, there is problem at the setting of self trigger mode.

• Our goal is to identify/remove the noise.– If heater current is the reason, then we should see any changeable results

from it.

– We should check it by taking data with the default setting as previous.

Run parameters

Run#, #/events,

File name

Configuration

Specify PCs for DAQ

Run options Staring data taking

Start/Stop/Abort

This is copy from ALICE web-page.

Slow progress for DATE

Last week Yesterday Goal in RAL?

Yesterday, reach to goal, but 2nd try was failed….=> finish in next week at RAL!

VLSB data format for new firmware (ver. “ce”)

Old Version “cc” New Version “ce”

Header First 4/5 lines (variable) 7 dummy lines (fix?)

+ Trigger location (line#8&9)

+ Discriminator hit map (line#10-17)

Body Channel address/ADC(128) Channel address/ADC(128)

Footer 2/3 lines 0 line?

TOTAL 135 145

12345678910

11

12

13

14

15

16

17

18

19

20

23

21

24

25

26

27

28

29

30

31

32

22

32-bit VLSB data

ADC ADCCounter Status bit

10 lines are added for debug information. “ce” is soon available.

-- Need to check header length to kwame --

Check numbers for cosmic-ray test

• 2 VME crates– Slow control will be separated from DAQ crate.

• 8 AFEIIt boards– To readout 5 stations, we need 3200 channels in total.

• 8 VLSB modules– 1 VLSB is needed to readout 1 AFE board

• 1 ADC & TDC module– Used for readout defining counter

To readout 5 stations….

Upside Define counter

Downside Define counter

Low energy filter block

Light shield box embedded 5 stations

2channles for TDC/ADC

2channles for TDC/ADC

3200(640 x5) channels for VLSB

Patch panel

Requires 4 for TDC/ADC & 3200 for VLSB

How many channels are used?

#1 #2#3

#4#5

8 AFEIIt boards = 8 VLSB modules

How about VLSB modules?This cabling is virtual.

Setup for test bench (R12)

V27

18

MIL

155

3

V27

18

V12

70

V17

24

VL

SB

VL

SB

VL

SB

VL

SB

VL

SB

VL

SB

VL

SB

VL

SB

V97

7

DAQ(LDC/GDC)

Slow control/Monitoring

Optical cable

Optical cable

VME crate

VME crate

Schedule

• This week (~13th)– Checking signals for newly RHB today!

– Testing code for VLSB module in Imeprial.• Waiting for driver for SBS(Bit3) dataBLIZZARD.

– Implement readout code for new firmware (ce).

• Next week (16th ~ 20th)– Set up test bench at R12 in RAL with JSG/Mike/Nicholls/Craig/etc.

• Clone system for Geneva University

– Testing code for CAEN modules(V977, V1270, V1724) in RAL.

– To test VLSB modules in RAL, need more modules! Please send to RAL!• Imperial’s VLSB will be in use for QA.

• The week after next (23rd ~ 27th)– DAQ workshop (23,24,25)

– Finish to setup DAQ system (mainly to debug readout program, I think)

R12Here coming 2 cryostats & 1 compressor & 1 transformer & 8 AFE boards & 5 stations & 25 inter/external waveguides & 1 patch panel & 2 VME crates & 2 NIM crates & VME/NIM modules & 2 DAQ PCs & other stuff…