department of the army - ctsfl.us · 6/21/2018 · to construct 236 apartment units in 5 buildings...
Post on 26-Aug-2020
0 Views
Preview:
TRANSCRIPT
Regulatory Division West Permits Branch Tampa Permits Section SAJ-2009-01024 (SP-PTR)
Mr. Robert Moreyra CRP II – Tarpons Springs LLC 2501 MacDill Avenue Tampa, Florida 33629 Via email – rmoreyra@ForgeCapitalPartners.com
Dear Mr. Moreyra:
The U.S. Army Corps of Engineers (Corps) is pleased to enclose the Department of the Army permit, which should be available at the construction site. Work may begin immediately but the Corps must be notified of:
a. The date of commencement of the work,
b. The dates of work suspensions and resumptions of work, if suspended over aweek, and
c. The date of final completion.
This information should be mailed to the Special Projects and Enforcement Branch of the Regulatory Division of the Jacksonville District at 10117 Princess Palm Avenue, Suite 120, Tampa, Florida 33610. The Special Projects and Enforcement Branch is also responsible for inspections to determine whether Permittees have strictly adhered to permit conditions.
IT IS NOT LAWFUL TO DEVIATE FROM THE APPROVED PLANS ENCLOSED.
Sincerely,
Tori K. White Chief, Regulatory Division
Enclosures
DEPARTMENT OF THE ARMY
JACKSONVILLE DISTRICT CORPS OF ENGINEERS
10117 PRINCESS PALM AVENUE, SUITE 120
TAMPA, FLORIDA 33610
June 21, 2018 REPLY TO
ATTENTION OF
Copies Furnished w/ enclosures:
Mr. Drew Sanders - Drew.Sanders@cardno.com
DEPARTMENT OF THE ARMY PERMIT
Permittee: CRP II – Tarpons Springs LLC 2501 S. MacDill Avenue Tampa, Florida
Permit No: SAJ-2009-01024
Issuing Office: U.S. Army Engineer District, Jacksonville
NOTE: The term "you" and its derivatives, as used in this permit, means the permittee or any future transferee. The term "this office" refers to the appropriate district or division office of the U.S. Army Corps of Engineers (Corps) having jurisdiction over the permitted activity or the appropriate official of that office acting under the authority of the commanding officer.
You are authorized to perform work in accordance with the terms and conditions specified below.
Project Description: To construct 236 apartment units in 5 buildings with approximately 390 parking spaces, a single storm water treatment pond (1.01 ac.), appropriate access drives and infrastructure and 2 mixed use outparcels totaling 1.99 acres. Total project site is 10.9 acres. The amount of wetland impact which is being authorized includes filling of 5.84 acres of wetlands. The proposed mitigation credits will provide 2.89 units of Functional Gain (FG): freshwater non-forested (emergent) mitigation credits 0.22; freshwater forested (Palustrine) mitigation credits 2.67 thru the Old Florida Mitigation Bank.
Project Location: South Pinellas Avenue, at Sections 13, Township 27 South, Range 15 East, Pinellas County, Florida.
Directions to site: From the intersection of Meres Avenue and South Pinellas Avenue go south 0.15 miles, project location is on the left.
Approximate Central Coordinates: Latitude: 28.135026 North Longitude: -82.756573West
Permit Conditions
General Conditions:
1. The time limit for completing the work authorized ends on . If you find that you need more time to complete the authorized activity, submit your request for a
June 21, 2023.
PERMIT NUMBER: SAJ-2009-01024 PERMITTEE: PAGE 2 of 9
time extension to this office for consideration at least one month before the above date is reached.
2. You must maintain the activity authorized by this permit in good condition and inconformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area.
3. If you discover any previously unknown historic or archeological remains whileaccomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and State coordination required to determine if the remains warrant a recovery effort or if the site is eligible for listing in the National Register of Historic Places.
4. If you sell the property associated with this permit, you must obtain the signatureand the mailing address of the new owner in the space provided and forward a copy of the permit to this office to validate the transfer of this authorization.
5. If a conditioned water quality certification has been issued for your project, youmust comply with the conditions specified in the certification as special conditions to this permit. For your convenience, a copy of the certification is attached if it contains such conditions.
6. You must allow representatives from this office to inspect the authorized activity atany time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit.
Special Conditions:
1. Commencement Notification: Within 10 days from the date of initiating thework authorized by this permit/Within 10 days from the date of initiating the workauthorized by this permit for each phase of the authorized project, the Permitteeshall provide a written notification of the date of commencement of authorizedwork to the Corps.
2. Self-Certification: Within 60 days of completion of the work authorized by thispermit, the Permittee shall complete the attached “Self-Certification Statement ofCompliance” form as provided in the attachment section of this permit and submit
PERMIT NUMBER: SAJ-2009-01024 PERMITTEE: PAGE 3 of 9
it to the Corps. In the event that the completed work deviates in any manner from the authorized work, the Permittee shall describe the deviations between the work authorized by this permit and the work as constructed on the “Self-Certification Statement of Compliance” form. The description of any deviations on the “Self-Certification Statement of Compliance” form does not constitute approval of any deviations by the Corps.
3. Agency Changes/Approvals: Should any other agency require and/or approvechanges to the work authorized or obligated by this permit, the Permittee isadvised a modification to this permit instrument is required prior to initiation ofthose changes. It is the Permittee’s responsibility to request a modification ofthis permit from the Tampa Permits Section. The Corps reserves the right to fullyevaluate, amend, and approve or deny the request for modification of this permit.
4. Posting of Permit: The Permittee shall have available and maintain forreview a copy of this permit and approved plans at the construction site.
5. Cultural Resources/Historic Properties:
a. No structure or work shall adversely affect impact or disturb properties listed inthe National Register of Historic Places (NRHP) or those eligible for inclusion in the NRHP.
b. If during the ground disturbing activities and construction work within the permitarea, there are archaeological/cultural materials encountered which were not the subject of a previous cultural resources assessment survey (and which shall include, but not be limited to: pottery, modified shell, flora, fauna, human remains, ceramics, stone tools or metal implements, dugout canoes, evidence of structures or any other physical remains that could be associated with Native American cultures or early colonial or American settlement), the Permittee shall immediately stop all work and ground-disturbing activities within a 100-meter diameter of the discovery and notify the Corps within the same business day (8 hours). The Corps shall then notify the Florida State Historic Preservation Officer (SHPO) and the appropriate Tribal Historic Preservation Officer(s) (THPO(s)) to assess the significance of the discovery and devise appropriate actions.
c. Additional cultural resources assessments may be required of the permit areain the case of unanticipated discoveries as referenced in accordance with the above Special Condition ; and if deemed necessary by the SHPO, THPO(s), or Corps, in accordance with 36 CFR 800 or 33 CFR 325, Appendix C (5). Based, on the circumstances of the discovery, equity to all parties, and considerations of
PERMIT NUMBER: SAJ-2009-01024 PERMITTEE: PAGE 4 of 9
the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume on non-federal lands without written authorization from the SHPO for finds under his or her jurisdiction, and from the Corps.
d. In the unlikely event that unmarked human remains are identified on non-federal lands, they will be treated in accordance with Section 872.05 Florida Statutes. All work and ground disturbing activities within a 100-meter diameter of the unmarked human remains shall immediately cease and the Permittee shall immediately notify the medical examiner, Corps, and State Archeologist within the same business day (8-hours). The Corps shall then notify the appropriate SHPO and THPO(s). Based, on the circumstances of the discovery, equity to all parties, and considerations of the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume without written authorization from the State Archeologist and from the Corps.
6. Erosion Control: Prior to the initiation of any work authorized by this permit,the Permittee shall install erosion control measures along the perimeter of allwork areas to prevent the displacement of fill material outside the work areainto waters of the United States. Immediately after completion of the finalgrading of the land surface, all slopes, land surfaces, and filled areas shall bestabilized using sod, degradable mats, barriers, or a combination of similarstabilizing materials to prevent erosion. The erosion control measures shallremain in place and be maintained until all authorized work is completed andthe work areas are stabilized.
7. Fill Material: The Permittee shall use only clean fill material for this project.The fill material shall be free from items such as trash, debris, automotiveparts, asphalt, construction materials, concrete block with exposedreinforcement bars, and soils contaminated with any toxic substance, in toxicamounts in accordance with Section 307 of the Clean Water Act.
8. Mitigation Bank Credit Purchase: Within 30 days from the date of initiatingthe work authorized by this permit, the Permittee shall provide verification tothe Corps that 2.89 credits of (0.22 for emergent mitigation and 2.67 forPalustrine mitigation) federal mitigation bank credits have been purchased fromthe Old Florida Mitigation Bank (SAJ-2013-01810). The required verificationshall reference this project's permit number (SAJ-2009-01024).
PERMIT NUMBER: SAJ-2009-01024 PERMITTEE: PAGE 5 of 9
Further Information:
1. Congressional Authorities: You have been authorized to undertake the activitydescribed above pursuant to:
( ) Section 10 of the Rivers and Harbors Act of 1899 (33 U.S.C. 403)
( ) Section 404 of the Clean Water Act (33 U.S.C. 1344)
( ) Section 103 of the Marine Protection, Research and Sanctuaries Act of 1972 (33 U.S.C. 1413)
2. Limits of this authorization.
a. This permit does not obviate the need to obtain other Federal, State, or localauthorizations required by law.
b. This permit does not grant any property rights or exclusive privileges.
c. This permit does not authorize any injury to the property or rights of others.
d. This permit does not authorize interference with any existing or proposedFederal projects.
3. Limits of Federal Liability. In issuing this permit, the Federal Government does notassume any liability for the following:
a. Damages to the permitted project or uses thereof as a result of other permittedor unpermitted activities or from natural causes.
b. Damages to the permitted project or uses thereof as a result of current or futureactivities undertaken by or on behalf of the United States in the public interest.
c. Damages to persons, property, or to other permitted or unpermitted activities orstructures caused by the activity authorized by this permit.
d. Design or construction deficiencies associated with the permitted work.
e. Damage claims associated with any future modification, suspension, orrevocation of this permit.
PERMIT NUMBER: SAJ-2009-01024 PERMITTEE: PAGE 6 of 9
4. Reliance on Applicant's Data: The determination of this office that issuance of thispermit is not contrary to the public interest was made in reliance on the information you provided.
5. Reevaluation of Permit Decision: This office may reevaluate its decision on thispermit at any time the circumstances warrant. Circumstances that could require a reevaluation include, but are not limited to, the following:
a. You fail to comply with the terms and conditions of this permit.
b. The information provided by you in support of your permit application proves tohave been false, incomplete, or inaccurate (see 4 above).
c. Significant new information surfaces which this office did not consider inreaching the original public interest decision.
Such a reevaluation may result in a determination that it is appropriate to use the suspension, modification, and revocation procedures contained in 33 CFR 325.7 or enforcement procedures such as those contained in 33 CFR 326.4 and 326.5. The referenced enforcement procedures provide for the issuance of an administrative order requiring you comply with the terms and conditions of your permit and for the initiation of legal action where appropriate. You will be required to pay for any corrective measures ordered by this office, and if you fail to comply with such directive, this office may in certain situations (such as those specified in 33 CFR 209.170) accomplish the corrective measures by contract or otherwise and bill you for the cost.
6. Extensions: General Condition 1 establishes a time limit for the completion of theactivity authorized by this permit. Unless there are circumstances requiring either a prompt completion of the authorized activity or a reevaluation of the public interest decision, the Corps will normally give favorable consideration to a request for an extension of this time limit.
June 21, 2018
For:
PERMIT NUMBER: SAJ-2009-01024 PERMITTEE: PAGE 8 of 9 When the structures or work authorized by this permit are still in existence at the time the property is transferred, the terms and conditions of this permit will continue to be binding on the new owner(s) of the property. To validate the transfer of this permit and the associated liabilities associated with compliance with its terms and conditions, have the transferee sign and date below. _______________________________________ ____________________ (TRANSFEREE-SIGNATURE) (DATE) _______________________________________ (NAME-PRINTED) _______________________________________ (ADDRESS) ______________________________________________________ (CITY, STATE, AND ZIP CODE)
PERMIT NUMBER: SAJ-2009-01024 PERMITTEE: PAGE 9 of 9
Attachments to Department of the Army Permit Number SAJ-2009-01024
1. PERMIT DRAWINGS: "Meres Crossing Phase 3. Pinellas County, Fl." Wetlands Map and "Meres Crossing Phase 3, Pinellas County, Fl." sheets 7 through 13, dated August 21, 2017, revised August 25, 2017 and sheet 6, dated August 21, 2017, revised February 19, 2018, scale as noted, drawn by CARDNO, 3905 Cresent Park Drive, Riverview, Florida. 2. SELF-CERTIFICATION FORM: 1 page
kj
kj
Upland Data Point
Wetland Data Point
rIm age:2014
Sec 13 T wp 27 S Rng 15 E
Data Source: Meres Crossing Phase 3Pinellas County, Florida
Wetlands Map
0 100 200 Feet
0 30.5 61 Meters
LegendProject Boundary - 10.90 ac.
Wetlands - 5.84 ac. ±
Wetland Im pacts Approv ed and Mitigated under Meres Crossing Ph ase 2 SAJ-2006-07545
Wetland Line
kj Wetland Data Point
kj Upland Data Point
File Path : Q:\UnitedStates\Florida\T am pa\CRP_II_T arpon_Springs_LLC\Meres_Ph ase_3\work ing\arcm ap\Meres_Ph ase3_Wetland_Map_B_20170825.m xdDate Rev ised: 8/25/2017GIS Analyst: Jam es.BottigerDate Created: 8/25/2017
T h is m ap and all data contained with in are supplied as iswith no warranty. Cardno Inc. expressly disclaim sresponsibility for dam ages or liability from any claim sth at m ay arise out of th e use or m isuse of th is m ap. It isth e sole responsibility of th e user to determ ine if th e dataon th is m ap meets th e user’s needs. T h is map was notcreated as surv ey data, nor sh ould it be used as such . Itis th e user’s responsibility to obtain proper surv ey data,prepared by a licensed surv eyor, wh ere required by law.
3905 Crescent Park Drive, Riverview, FL 33578 USAPhone (+1) 813-664-4500 Fax (+1) 813-664-0440 www.cardno.com
PROPOSED WETLANDIMPACT (5.84 ac.)
WETLAND ENHANCEMENTAREA (REQUIRED BYOTHERS 1.06 AC.)
10.04
'
RET
AIL
OR
OTH
ERAP
PRO
VED
USE
9,81
0 SF
RET
AIL
OR
OTH
ERAP
PRO
VED
USE
13,3
28 S
F
RET
AIL
'A' R
ETAI
L O
RO
THER
APP
RO
VED
USE
6,60
0 SF
110'
x 6
0'
10.04
'
T
TT
T
10.04
'
1
3
2
2
3
3
3
3
3
(-)1
910
3
3
3
7 5
3
57
89
10
57
89
10
3
78
35
7
8
56
78
910
11
4
4
10
6
22
8
34
3
2
2
45
6
3
45
4
3
3
4
6
9
6
6
4
2
2
2
4
POND A1.01 AC
BUILDING 14 STORIES23,000 SF
BUILDING 53 STORIES16,217 SF
BUILDING 43 STORIES22,649 SF
BUILDING 33 STORIES15,752 SF
A
F
B
C
D
E
G
G
H
BUILDING 23 STORIES18,485 SFST
ATE
ROAD
NO
. 595
(ALT
. 19)
Access toPinellas Trail
ExistingHospital
ExistingWinn Dixie
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/21/2017 Rev. Date: 2/19/2018PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\unitedstates\Florida\Tampa\crp_ii_tarpon_springs_llc\meres_phase_3\working\cad\Overall Plan.dwg
Rng 15 ETwn 27 SSec 13
Sheet - 06Overall Plan
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc. expressly disclaimsresponsibility for damages or liability from any claims that mayarise out of the use or misuse of this drawing. It is the soleresponsibility of the user to determine if the data on thisdrawing meets the user’s needs. This drawing was notcreated as survey data, nor should it be used as such. Itis the user’s responsibility to obtain proper surveydata, prepared by a licensed surveyor, where requiredby law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
00 100' 200'feet
PIN
ELLA
S TR
AIL
WETLAND
-202468
10121416
4:1
ASCALE: HORIZ. 1"=20'
VERT. 1"=4'
LP
4:1
EXISTING GRADE
15'
ASPHALTTRAIL
PINELLAS TRAIL ROWO.R.B. 9424, PG. 395
PROPOSED GRADE
5:1
BLDG. F.F.EL. = 12.00
PROPOSED BULDING 4(DESIGNED BY OTHERS)
PROPOSED 2' OF FLATAREA ABUTTINGPINELLAS TRAIL
EXISTING FENCE TO BEREMOVED
0-40 -20 20 40 60
EXISTING TRAIL TOREMAIN
VARIES LIMITS OF SOD
- FILL
-202468
10121416 MERES
CROSSINGPHASE 3
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/21/2017 Rev. Date: 8/25/2017PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\UnitedStates\Florida\Tampa\CRP_II_Tarpon_Springs_LLC\Meres_Phase_3\working\cad\Cross Sections A.dwg
Rng 15 ETwn 27 SSec 13ACOE
Sheet - 07
Cross Sections
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc.
required by law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
02468
10121416LP
0-20 20 40 60
TOB EL. = 8.00
BOTT. EL.= 5.00
4:1
4:1
EXISTING GRADE
PROPOSED GRADE
VARIESPOND TRACT
35'ROAD TRACT
BLDG. 2PARKINGGARAGE
PROPOSEDSIDEWALK
VARIESPOND AMEET EXISTING
GRADE
EXISTING FENCE TOREMAIN
80 100 120 140 160 180 200 220 240
VARIESEXISTING POND TO BE REGRADED
BSCALE: HORIZ. 1"=20'
VERT. 1"=4'
100-YR/24 HRDHW = 7.90 25-YR/24 HR
DHW = 7.62
5' BERM
PROPOSED REMOVAL OF SP-SM FINE SANDSWITH SILT (ELEVATIONS 0.5' TO 4.5'). REPLACEWITH FILL HYDRAULIC SOIL TYPE "A"
PROPOSED 18" RCP
SHW. EL.= 1.00
- FILL
02468
10121416
WETLAND
MERES CROSSING PHASE III
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/24/2017 Rev. Date: 8/25/2017PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\UnitedStates\Florida\Tampa\CRP_II_Tarpon_Springs_LLC\Meres_Phase_3\working\cad\Cross Sections B.dwg
Rng 15 ETwn 27 SSec 13ACOE
Sheet - 08
Cross Sections
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc.
required by law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
-202468
10121416
CSCALE: HORIZ. 1"=20'
VERT. 1"=4'
0 20204060
EXISTING FENCE TOBE REMOVED
LPMERES PHASE IIMERES PHASE III
PROPOSEDPAVEMENT
EXISTINGSHEET PILETO REMAIN
2468
101214161820
DSCALE: HORIZ. 1"=20'
VERT. 1"=4'
0-20 20 40
LP
4:1
PERIMETERWALL. SEE ARCH
PLANS
MERES CROSSING PHASE IIIHOSPITAL SITE
MEET EXISTINGGRADE
PROPOSED 48"STORMPIPE
EXISTING SANITARYSEWER MANHOLE
PROPOSED 8" DIPGRAVITY SEWER LINE
± 0.5 FEETCLEARANCE
BLDG. 10GARAGE
VARIES
PROPOSEDPAVEMENT
- FILL- FILL
2468
101214161820
-202468
10121416 WETLAND
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/24/2017 Rev. Date: 8/25/2017PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\UnitedStates\Florida\Tampa\CRP_II_Tarpon_Springs_LLC\Meres_Phase_3\working\cad\Cross Sections C&D.dwg
Rng 15 ETwn 27 SSec 13ACOE
Sheet - 09
Cross Sections
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc.
required by law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
EXISTING GROUND
-2
0
2
4
6
8
10
12
14
16 ROW LC
84'STATE ROAD 595RIGHT-OF-WAY
ROW
MERES CROSSING PHASE III
PROPOSEDVALLEY CURB8" PVC C-900
WATERMAIN 4" PVC C-900WATERMAIN
ESCALE: HORIZ. 1"=20'
VERT. 1"=4'
0-40 -20 20 40
-7.41%
0.31%
PROPOSEDASPHALTPAVEMENT
1 12" FC-12.5
PROPOSED 48" RCP
20'PROPOSEDDRAINAGEEASEMENT
APPROXIMATELOCATION OF EXISTING6" WATER MAIN
PROPOSED SIDEWALK@2.0% MAX CROSS SLOPE
5.5%
APPROXIMATELOCATION OF EXISTING16" HDPE WATER MAINWITH 16"x10" TEE AND10" GATE VALVE
PROPOSEDCONNECTION TOEXISTING 10" STUB-OUTWITH EXISTING VALVE &PROPOSED CHLORINEINJECTION -2
0
2
4
6
8
10
12
14
16
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/24/2017 Rev. Date: 8/25/2017PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\UnitedStates\Florida\Tampa\CRP_II_Tarpon_Springs_LLC\Meres_Phase_3\working\cad\Cross Sections E.dwg
Rng 15 ETwn 27 SSec 13ACOE
Sheet - 10
Cross Sections
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc.
required by law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
-202468
10121416
4:1
FSCALE: HORIZ. 1"=20'
VERT. 1"=4'
LP
4:1
EXISTING GRADE
PINELLAS TRAIL ROWO.R.B. 9424, PG. 395
PROPOSED GRADE
PROPOSED 2' OF FLATAREA ABUTTINGPINELLAS TRAIL
EXISTING FENCE TO BEREMOVED
0-40 -20 20 40 60
EXISTING TRAIL TOREMAIN
8'19'
SLOPEDBOARDWALK
HARDSCAPE AREA2% MAX SLOPE
6.0'19'
LANDING STEPS
40'
CONC. SIDEWALK
PROPOSED PEDESTRIANWALKWAY/TRAIL CONNECTION.
MERES CROSSING PHASE III
-202468
10121416
LP
0-40 -20 20 40 60
VARIES
TYPE "D"CURB
PROPOSEDPAVEMENT
4:1 4:1
PROPOSEDRETAINING WALLPER FDOT INDEX6010
EXISTINGGROUND
PROPOSEDGRADE
EXISTING FENCE TO BEREMOVED
EXISTING TRAIL TOREMAIN
HSCALE: HORIZ. 1"=20'
VERT. 1"=4'
PROPOSED 2' OF FLATAREA ABUTTINGPINELLAS TRAIL
PROPOSED CONCRETEBOLLARD
WW
- FILL- FILL
-202468
10121416
-202468
10121416
PINELLAS TRAIL ROWO.R.B. 9424, PG. 395
MERES CROSSING PHASE III
WETLAND
WETLAND
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/24/2017 Rev. Date: 8/25/2017PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\UnitedStates\Florida\Tampa\CRP_II_Tarpon_Springs_LLC\Meres_Phase_3\working\cad\Cross Sections F&H.dwg
Rng 15 ETwn 27 SSec 13ACOE
Sheet - 11
Cross Sections
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc.
required by law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
0-4
48
121620
0-4
481216
20
GSCALE: HORIZ. 1"=100'
VERT. 1"=10'
10:1
10:1
PROPOSED GRADE
EL.= 2.00
VARIES
MEET EXISTINGGRADE
EL.= 3.00EL.= 2.00 EL.= 2.00 EL.= 2.00
TRAIL ACCESS BRIDGE
WETLAND ENHANCEMENT (REQUIRED BY OTHERS)
30" RCP
MEET EXISTING GRADE
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/24/2017 Rev. Date: 8/25/2017PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\UnitedStates\Florida\Tampa\CRP_II_Tarpon_Springs_LLC\Meres_Phase_3\working\cad\Cross Sections G.dwg
Rng 15 ETwn 27 SSec 13ACOE
Sheet - 12
Cross Sections
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc.
required by law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
ExistingHospital
ExistingWinn Dixie
13
(-)1
910
3
7 5
3
57
89
10
57
89
10
78
57
8
10
6
45
6
45
4
4
6
9
6
6
4
www.cardno.com
3905 Crescent Park Drive Riverview, FL 33578 USA
TLN JMB Creation Date: 8/21/2017 Rev. Date: 8/25/2017PM: CAD Operator: Revised By: James.Bottiger File Location:Q:\UnitedStates\Florida\Tampa\CRP_II_Tarpon_Springs_LLC\Meres_Phase_3\working\cad\Wetland Enhancement.dwg
Rng 15 ETwn 27 SSec 13
Sheet - 13Wetland Enhancement
Meres Crossing Phase 3Pinellas County, FL
This drawing and all data contained within are suppliedas is with no warranty. Cardno, Inc.
required by law.
Phone (+1) 813-664-4500 Fax (+1) 813-664-0440
00 100' 200'feet
WETLAND ENHANCEMENT AREAREQ'D BY OTHERS (1.06 AC.)
SELF-CERTIFICATION STATEMENT OF COMPLIANCE
Permit Number: Standard Permit Application Number: SAJ-2009-01024
Permittee’s Name & Address (please print or type):___________________________________
____________________________________________________________________________
____________________________________________________________________________
Telephone Number: ____________________________________________________________
Location of the Work: ___________________________________________________________
____________________________________________________________________________
Date Work Started: ____________________ Date Work Completed: ______________________
PROPERTY IS INACCESSIBLE WITHOUT PRIOR NOTIFICATION: YES ______ NO_______
TO SCHEDULE AN INSPECTION PLEASE CONTACT _______________________________ AT __________________________
Description of the Work (e.g. bank stabilization, residential or commercial filling, docks, dredging, etc.):________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
Acreage or Square Feet of Impacts to Waters of the United States: ______________________
Describe Mitigation completed (if applicable): ________________________________________
____________________________________________________________________________
____________________________________________________________________________
Describe any Deviations from Permit (attach drawing(s) depicting the deviations):
____________________________________________________________________________
____________________________________________________________________________ ********************
I certify that all work, and mitigation (if applicable) was done in accordance with the limitations and conditions as described in the permit. Any deviations as described above are depicted on the attached drawing(s).
______________________________ Signature of Permittee
______________________________ Date