design of tall rc buildings: core supported structures · pdf filedesign of tall rc buildings:...
Post on 17-Feb-2018
225 Views
Preview:
TRANSCRIPT
Design of Tall RC Buildings:
Core Supported Structures and Outrigger
Braced Systems
Example Writing Project from:
CE 764 – Advanced Design of Reinforced Concrete Structures
Fall Semester of 2014
1
Introduction
Gone are those days when the typical high self-weight of concrete used to impose a limitation on
the height of buildings. Appropriate structural forms along with high-strength and lightweight
concrete have conquered all economic constraints of a concrete high-rise. Rather, the significant
dead loads from concrete is, in other words, its greater stiffness, which minimizes the sway
deflection, floor vibration and local instability problems, and thereby make it more suitable for
high-rises (Taranath, 1988).
Selecting an efficient structural system in terms of both performance and economy is the key to
have an effective high-rise concrete structure. In general, the higher the structure, the more
significant is the lateral load. This demand also increases with increase in slenderness and
flexibility. To identify a proper structural system, considerations should be made not only to select
an appropriate lateral load resisting system, but also to deal with other non-structural issues –
functionality and aesthetics (from an architect’s perspective), leasability (from an owner’s
perspective), constructability (from a contractor’s perspective) and more.
The outward appearance of tallness is relative and there is no hard and fast rule regarding how to
categorize a building as ‘tall’; it is not defined in terms of height, number of floors or proportion.
According to some, it can be distinguished when dynamics plays a greater role in designing the
structure than statics. However, a building can also be treated as ‘tall’ when the effect of lateral
loads has to be reflected in its structural analysis and design. Therefore, to evaluate the
applicability of a structural system, all the factors that influence the lateral behavior – building
geometry, severity of wind exposure, seismicity of the region and the overall performance
expected from the structure – need to be considered.
2
To categorize all the structural systems into a number of distinct classes is a difficult, if not
impossible, task as there may exist almost as many structural concepts as there are engineers.
However, for presenting an opportunity for an engineer to compare or combine the characteristics
of two or more systems, the most common systems have been classified – core supported structure,
outrigger braced structures, shear wall structures and tubular structures are frequently used for
normally proportioned buildings of more than 30 stories. The scope of this paper is core supported
structures and outrigger braced structures – typically used for buildings 30 to 70 stories high and
normally proportioned – but there are examples when these structural systems, being combined
with others, have been successfully used for buildings with greater heights or unusual proportions
(Taranath, 1988).
Core Supported Structures
Rectangular box-shaped cores around stairs, elevators, and other shafts are one of the most
regularly used forms of shear walls, which also makes an efficient use of vertical enclosures that
are required around the cores. This system works quite well for commercial buildings, where
maximum flexibility in layout is required, so that the open spaces can be divided by movable
partitions. Other than the functional advantages, the structural benefits of this system is that being
spatial, the walls around the core are capable of resisting all types of loads – vertical forces, shear
forces, and bending moments in all directions, as well as torsion - especially when adequate
stiffness and strength are provided between flanges of open sections (Taranath, 1988).
In other words, shear cores may be considered as members that resist lateral loads in a way similar
to massive beams cantilevering out of the foundation; thus the shear and bending stresses observed
in a core are analogous to those of a box girder. Unlike conventional beams, the core has to carry
3
a significant amount of axial load (gravity load of the structure), which induces compressive forces
and as a result, the shear capacity of the structure is increased and the structure may not need to be
designed for tensile stresses, especially in case of heavy concrete cores.
Figure 1: Schematic response of core supported structure under vertical and lateral loading (Schueller, 1986)
Figure 1 illustrates the response of a central core system to gravity and wind loads. The gravity
loads increase progressively from almost zero at the top to maximum at the base, while the moment
response due to lateral load is similar to that of a cantilever beam subjected to uniformly distributed
load with maximum moment at the fixed end. To be more specific, this response of a core to lateral
loading depends upon its shape, the degree of homogeneity and rigidity, amount of continuity
provided by the spandrels, and the direction of the load (Schueller, 1986).
There is no restriction regarding the shape and location of the core within the building form. To a
large extent, the shape of the core is regulated by the elevator and stair layout. Variations in layout
4
of shear walls could occur from a single rectangular box core to a complicated arrangement of
multiple shear walls. The core can be located at the middle, at the perimeter, or even at the external
part of the building, leaving the arrangement to be either symmetrical or asymmetrical. Unless the
other vertical structural elements within the building consists of relatively closely spaced columns
and deep spandrel, it is more than likely that the stiffness of the core will overwhelm that of other
vertical elements; therefore it is justifiable to ignore the resistance of other vertical elements and
design the core system for the entire lateral load (Schueller, 1986).
Case Study 1: Burj Khalifa
Burj Khalifa, the 828m tall reinforced concrete tower structure, is an example of core supported
structures. Unlike typical core supported structures, this building was designed utilizing all of the
vertical members to support both gravity and lateral loads. The basic structural system consists of
a six-sided central hub with three wings clustered around it. The system can be described as a
‘buttressed core’, where each of the wings support the others via the central hexagonal core as
shown in Figure 2.
This central core, consisting of high performance concrete wall, provides the torsional resistance
of the structure. The corridor walls are extended from the central core to near the end of each wing
and are terminated in thickened hammer head walls. While resisting the shear and moment
demands induced from wind loads, these corridor walls behave similar to the webs and hammer
head walls behave like flanges. In addition to providing high structural performance and enhancing
the views from the building, the spiraling ‘Y’ shaped design helps to reduce the wind forces on the
tower along with fostering construction by keeping the structure simple (Baker et al., 2007).
5
Figure 2: 3D view of a single story model of Burj Khalifa (Baker et al., 2007).
The rest of the structural system is the perimeter columns with a flat plate floor system. At
mechanical floors, 3-story high outrigger walls are used. These walls link the perimeter columns
to the interior corridor walls and thereby, force them to be a part of the lateral load resisting system.
With that, not only the gravity load resisting system is almost fully utilized to resist lateral loads,
but also the structure is extremely stiff, both laterally and torsionally (Baker et al., 2007).
As the tower rises, the setback of the wings – one wing at each tier in an upward helical pattern -
provides many different floor plates and a decreasing cross section as the tower reaches toward the
sky in 26 spiral levels, giving a visual impression of a series of towers of differing heights shown
in Figure 3. To avoid the presence of any structural transfers so that a direct downward load path
Central hexagonal core
Hammer head walls
Corridor walls
6
can be ensured, the setbacks are structured with the tower’s grids. The stepping of the building is
accomplished by simply aligning columns above with walls below. As these setbacks provide
different widths for each differing floor plate, the wind has to encounter a different building shape
at each new tier over the height of the structure; and as a result wind vortices never get organized.
Thus, this upward spiraling pattern of setbacks along with the ‘Y’ shaped floor plans, determined
based on extensive wind tunnel tests using the concept of “confusing the wind”, help reduce the
wind force significantly (Baker et al., 2007).
Figure 3: Floors of Burj Khalifa showing setback at different level (http://en.wikipedia.org/wiki/Burj_Khalifa).
7
Outrigger Braced Structures
An outrigger is a part of a boat's rigging which is rigid and extends beyond the side or gunwale of
a boat to stabilize an inherently unstable main hull. The outrigger is positioned rigidly and parallel
to the main hull so that the main hull is less likely to capsize. Originating from this concept, an
outrigger-braced high-rise structure consists of a central core and flexurally stiff horizontal
cantilever ‘outrigger’ girders connecting the core to the exterior columns. Under lateral loads, the
windward column-restrained outriggers restrain the vertical plane rotations through tension and
the outriggers in the leeward columns through compression. This reduces both lateral deflection
and bending moments in the core from that if the free-standing core were the only resisting system.
In other words, by connecting some of the perimeter columns to the central core, the outriggers
ensure a partly composite cantilever type behavior of the whole structure. This efficient structural
system increases the effective structural depth of the building when it flexes as a vertical cantilever,
which thereby enhances the lateral stiffness of the building and reduces the lateral deflections as
well as the moments in the core, as illustrated in Figure 4. To utilize the other peripheral columns,
which are not directly connected to the ends of the outriggers, a horizontal deep spandrel girder
joins all the perimeter columns around the face of the building at the outrigger level (Smith and
Coull, 1991).
The extent of the composite behavior of an outrigger braced structure depends upon the stiffness
and the number of outrigger levels. Though multilevel outrigger structures show a significant
increase in their lateral moment resisting capacity over single outrigger structures, the degree of
this increase reduces with each additional level of outriggers. Using up to four outrigger levels has
been shown to be economical in very tall buildings. Though the outrigger system is very effective
8
in increasing the structure’s flexural stiffness, shear resistance of the structure is almost entirely
provided by the core (Smith and Coull, 1991).
Figure 4: Typical Deflection and moment pattern of outrigger braced structures. (Smith and Coull, 1991)
Unlike the approximate methods of analysis for other types of high-rise structures, where
advantage can be taken of the repetitive story-to-story arrangement, the outrigger braced structure
has to be considered in its discreet arrangement. Using compatibility method, the rotations of the
core at the outrigger levels are matched with that of the corresponding outriggers. The assumptions
that are the basis of this method are – the behavior of the structure is in the linear elastic range,
axial forces are the only forces induced in the columns, both the outrigger-core connection and the
core-foundation connection are sufficiently rigid, and the cross-sectional properties of all the
structural elements – core, columns, and outriggers – are uniform throughout their height. These
assumptions may appear to be impractical because in a real life structure the dimensions of the
9
vertical members reduce with the increase in height. However, the key factors in a preliminary
analysis (such as the drift at the top, the moment at the base of the core, the axial forces in the
columns) are mostly affected by the properties of the lower level of the structure. Therefore, an
analysis of a hypothetical uniform structure with properties taken from lower level of the actual
structure can result in a sufficiently accurate preliminary design (Smith and Coull, 1991).
Case Study 2: Aston Apartments, Sydney
Aston Apartments is a residential building accommodating 145 serviced and owner occupied units.
This reinforced concrete framed structure is a slender 30-story tower having a height-to-base ratio
of 7:1 as the 90m high building has a width of only 13 meters in the north-south direction. The
structure called for an exclusive design solution due to this slender form and difficult positioning
(Dean et al., 2001).
An innovative wind resisting system using ‘offset outriggers’ has been developed for this building,
which significantly reduces building deflections and core bending stresses. To overcome the
drawbacks of typical outrigger systems, where outrigger arms commonly obstruct valuable
serviceable floor space, the ‘offset’ system allows the outrigger arms to be placed across the width
of the building at locations away from the central core as shown in Figure 5.
Detailed structural analysis for Aston Apartments have shown that for typical floor slab plan
dimensions, the effectiveness of the conventional outrigger system, which requires the core and
external columns to be directly coupled, is not significantly higher than that of the offset outriggers
if they are further from the center core. In this structure, the floor diaphragms transfer opposing
shear forces at the top and bottom levels of the outriggers to activate the perimeter columns of the
building by introducing a coupling action between the columns and the core. As shown in Figure
10
5, the 200mm thick, two story high shear walls of Aston Apartments are located on the side
elevations at mid-height and the top of the building, ensuring essentially no influence on the
interior planning of the building and maximizing flexibility for the architect (Dean et al., 2001).
Figure 5: Frame Perspective - Aston Apartments (Dean et al., 2001)
Moreover, in conventional outrigger structures, where the core and columns are rigidly connected
by outriggers, there always remains a possibility of differential shortening between them. In case
of the offset outriggers of Aston Apartments, the outrigger walls effectively link perimeter
11
columns of similar load, so that the deflection can be expected to be similar as well. These offset
outriggers utilize the axial strength of the perimeter columns to resist the load at maximum lever
arm, and thus are very economical and efficient. The presence of these outriggers not only limit
the drift of the building, but also reduce the bending actions in the core resulting in a reduction in
the core wall thickness as well as the steel reinforcement. This system is so effective in reducing
the requirement of reinforcement of the central core that it can be designed for resisting only 20%
of the total base bending moment. To be more precise, as an advantage of the optimal location of
the outriggers in Aston Apartments, the thickness of the core wall is 200mm over the entire 30
stories, and this exceptional absence in the variation of thickness made the core very simple and
quickly constructible. (Dean et al., 2001)
Conclusion
Core supported systems and outrigger braced systems are two of the most frequently used lateral
load resisting systems for concrete high-rises. The innovation of these systems brought an end to
an era when the tallest of the buildings were inevitably steel buildings. The art of designing tall
buildings is to bestow them with enough strength to resist forces generated by windstorms and
earthquakes and enough stiffness or energy dissipation so that safety is never at stake. Concrete
high-rises have been successfully designed using these concepts and have been proven to exhibit
such satisfactory structural behavior – having minimized lateral deflection, being adequately
strong and dissipating as much energy as required to ensure life safety.
These established structural systems, despite of being proved as effective and efficient, sometimes
are just not enough for a specific condition, or even if they are, the scope of improvement has no
bounds. Much engineering judgment supported by applicable experiments are required to reach a
12
sound conclusion. It’s not possible if being limited by only the existing theories; the key is rather
to explore ideas and concepts, to blend the brilliance of the past with imagination for the future.
The two case studies presented here were examples of surpassing the precincts of basic structural
concepts and emerging with an exclusive solution most suitable for the specific circumstance.
References
• Baker, W. F., Korista, D. S. and Novak, L. C. (2007). “Burj Dubai: Engineering the
World’s Tallest Building.” Struct. Design Tall Spec. Build. 16, 361 – 375.
• “Burj Khalifa.” (2014).〈http://en.wikipedia.org/wiki/Burj_Khalifa〉 (Dec. 05, 2014).
• Dean, B., Martin, O., Emery, D., and Chancellor, P. (2001). “Tall building design
innovations in Australia.” Proc, CTBUH 6th World Congress, Melbourne.
• Schueller, W. (1986). “High-rise Building Structures.” Robert E. Kreiger Publishing
Company, Malabar, Florida.
• Smith, B. S., and Coull, A. (1991). “Tall Building Structures: Analysis and Design”. John
Wiley and Sons, Inc.
• Taranath, B. S. (1988). “Structural Analysis & Design of Tall Buildings.” McGraw-Hill
Book Co., Singapore.
top related