Specifications subject to change without notice.
Rev. 0.2
AMUS Series Load Cells
www.hfn-br.com 01
AMUS Series
They can be interconnected to Tablets and Industrial Computers with Load Monitoring Software.
They can be provided with other communication options, such as:
Standard Version with Long Range Wireless HFN® BD-2008LR System powered by AA batteries. The HFN® BD-2008 series displays and modems form a rugged, low-power telemetry system with a range of up to 450m.
>> 0-10Vdc; -10-10Vdc, 4-20 mA; TCP / IP; Serial RS232 / RS485 (others on request).
Practical and robust for the most diverse applications. The unique design of the HFN® Amus load cells enables load measurements in various situations without the use of auxiliary shackles, which makes it a specialist in high capacity and low cost measurements
- Measurements of general loads of very high capacity;
- Maritime Industry and Oil & Gas.
for the following applications:
- Suspended weighing systems for industry;- Installed directly on high capacity cranes for accurate load measurement
HFN® AMus Series load cells are perfectly engineered
AMUS Series
Patented design, being the only model of tensile load cell manufactured in Brazil, with a capacity exceeding 400t, with certification tracked InMetro.
Load monitoring systems solutions
English
Wireless HFN® BD-2008LR System
They can be interconnected to Tablets and Industrial Computers with Load Monitoring Software.
The BD-2008 system operates on the free 2.4GHz frequency and has
Standard Version with Long Range Wireless HFN® BD-2008LR System powered by AA batteries. The HFN® BD-2008 series displays and modems form a rugged, low-power telemetry system with a range of up to 450m.
ANATEL certification.
Load Monitoring Systems Solutions
Rev. 0.2 www.hfn-br.com 02
AMUS Series
AMUS Series
Specification
Nominal capacity F.E. (t) 250t - 1000t
(outras sob consulta)
Accuracy Class 1 % Fnom
Relative linearity error % F.E. ≤ ± 1
Relative repetitiveness error % F.E. ≤ ± 0.5
Zero Displacement % F.E. ≤ ± 0.05
Reference temperature °C 23
Rated temperature range °C 0...+50
Usage temperature range °C -5...+70
Storage temperature range °C -10...+85
Effect of temperature on sensitivity by 10 ° C %/10°C ≤ ± 0.1
Efeito da temperatura no zero por 10°C %/10°C ≤ ± 0.1
Input Resistance Ohm 1080 ± 20
Output Resistance Ohm 1000 ± 20
Insulation Resistance (100V) GOhm > 5
Rated excitation voltage V 5
Excitation voltage operating range V 3...12
Limit load of safety % v. 150
Bursting load % F.E. > 400
Lateral force limit % F.E. 10
Permissible dynamic load (peak-to-peak according to
DIN50100)
% F.E. 70
Degree of protection EN 60529 IP67 (IP 68 Disponível)