7/27/2019 Dynamic Loads.pdf
1/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
DYNAMIC LOADSThere are two types of forces/loads that may act
on structures, namely static and dynamic forces.
Static forces are those that are gradually applied
and remain in place for longer duration of time.
These forces are either not dependent on time or
have less dependence on time.
Live load acting on a structure is considered as a
static load because it usually varies gradually in
magnitude and position.
-
7/27/2019 Dynamic Loads.pdf
2/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Similarly moving loads may also be considered
as statically applied forces.
Dynamic forces are those that are very much
time dependent and these either act for smallinterval of time or quickly change in magnitude or
direction.
Earthquake forces, machinery vibrations and blast
loadings are examples of dynamic forces.
Structural response is the deformation behavior
of a structure associated with a particular loading.
-
7/27/2019 Dynamic Loads.pdf
3/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Similarly, dynamic response is the deformationpattern related with the application of dynamic
forces.
In case of dynamic load, response of the
structure is also time-dependent and hence
varies with time.
Dynamic response is usually measured in terms
of deformations (displacements or rotations),velocity and acceleration.
-
7/27/2019 Dynamic Loads.pdf
4/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Dynamic force, F(t), is defined as a force that
changes in magnitude, direction or sense in muchlesser time interval or it has continuous variation
with time.
Impact loadis the other extreme where the load isapplied only for an infinitesimal interval of time with
some momentum and is considered separate from
the dynamic loads.
The variation of a dynamic force with time is called
history of loading.
Prescribed dynamic loadingis regularly varying
loading in which well-defined cycles of loading arerepeated after equal intervals of time.
-
7/27/2019 Dynamic Loads.pdf
5/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
F(t)
t
Fig. A Typical Dynamic Force.
Example of prescribed loading is a regularvibration of machinery with a certain amplitude
and frequency.
-
7/27/2019 Dynamic Loads.pdf
6/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Amplitude of vibration is the maximum
structural displacement during one completecycle of load.
Frequencyis the number of loading cycles in aunit time (usually one second).
Types Of Prescribed Loading
a) Periodic loading
i) Sinusoidal Loading:ii) Stepped Loading:
iii) Complex Variation Loading:
-
7/27/2019 Dynamic Loads.pdf
7/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
F(t)
t
F(t)
t
F(t)
t
Typical Sinusoidal Loading.
Typical Stepped Loading.
Typical Complex
Variation Loading.
-
7/27/2019 Dynamic Loads.pdf
8/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
b) Non-periodic loading
F(t)
t
Typical Impulsive Loading.
F(t)
t
Typical Earthquake Loading.
-
7/27/2019 Dynamic Loads.pdf
9/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
EARTHQUAKES
An earthquake is the vibration of earth produced
by rapid release of energy from within itself.
This extra energy may be stored in earth and
released at intervals due to many different
phenomena, some of which are as under:1. Plate tectonics.
2. Volcanic eruptions.3. Atomic explosions.
4. Collision of massive meteorites with thesurface of earth.
-
7/27/2019 Dynamic Loads.pdf
10/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Plate Tectonics
Crust: Crust is the outermost layer of earth
consisting of solid material varying in temperature
from surface temperature to a maximumtemperature of 1000 C. Its thickness under deepoceans is between 4 to 6 km and the thickness
under continents is approximately 30 to 40 km.
Mantle: This layer has an approximate thickness
of 3000 km and consists of semi-solid to plasticmaterial. The temperature ranges from 1000 to
3500 C.
-
7/27/2019 Dynamic Loads.pdf
11/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Outer Core: Outer core is a thickness of
approximately 2250 km and consists of liquid at atemperature of 3500 to 4000 C.
Inner Core: The inner core has a radius of
approximately 1200 km and is a layer of solid
material at temperature higher than 4000 C.
The outer layer of earth having a thickness of 100
km is relatively rigid and is called lithosphere.
The layer of earth below lithosphere having a
thickness of 400 km is softer and is called
asthenosphere.
-
7/27/2019 Dynamic Loads.pdf
12/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
The lithosphere acts as rigid plate that moves over
partly molten asthenosphere.
According to this theory, lithosphere is cracked in
places or broken in to smaller pieces or plates.
This may have happened during initial drying of
the earth from a molten state.
There are seven large and several small plates.
The largest plates are the Pacific plate, the NorthAmerican plate, the Eurasian plate, the Antarctic
plate, the Indo-Australian plate and the African
plate.
-
7/27/2019 Dynamic Loads.pdf
13/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Plate boundaries
a) Mid-Oceanic Ridge:
b) Subduction Zone:
Further, there are three types of plate boundaries
depending on the relative movement between thetwo adjoining plates.
i) Convergent Plate Boundary:ii) Divergent Plate Boundary:
iii) Transform Plate Boundary:
-
7/27/2019 Dynamic Loads.pdf
14/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
According to continental drift theory, all thecontinents were once part of a huge landmass,
which have slowly moved apart.
The Indian sub-continent was not a part of Asia.It drifted over millions of years from Australia to
Asia and the collision produced Himalayas.
Modern techniques such as GIS and GPS prove
such movements of continents.
Faults are cracks which are developed within the
main plates.
-
7/27/2019 Dynamic Loads.pdf
15/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
16/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
17/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
18/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
19/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
20/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
21/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Focus And Epicenter
The point within the earth along the rupturing
geological faults where an earthquake originates
is called the focus orhypocenter.
The point on the earths surface directly above
the focus is called the epicenter. Earthquakewaves radiate out from the focus.
The focal depth is the depth of the hypocenter
below the epicenter.
Focal distance is the distance from the
hypocenter to a given reference point.
-
7/27/2019 Dynamic Loads.pdf
22/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Earthquake / Seismic Waves
The waves originated at the rupture zone are
called body waves and are of the following two
types:
(1) P-Waves or Primary Waves or Dilation
Waves:
These waves involve particle movement parallel to
the direction of propagation of the wave, as shownin Fig.
The speed of travel of these waves is appr. 1.73
times greater than the other waves.
-
7/27/2019 Dynamic Loads.pdf
23/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
These waves are felt earlier in an earthquake
and cause relatively less damage.
There is usually an after-shockat an interval
during which the other more damaging wavesapproach the area.
Wave Direction Wave Direction
Particle Movement
Particle Movement
(a) P-Waves (b) S-Waves
-
7/27/2019 Dynamic Loads.pdf
24/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
(2) S-Waves or Secondary Waves or Shear
Waves:
These waves involve particle movement
perpendicular to the direction of propagation of thewave (refer the Fig.).
When body waves reach the ground surface, part
of these is reflected back while other part
produces surface waves.
Surface waves are the waves produced on theearths surface due to an earthquake and are of
following two types:
P f D Z hid A Siddi i UET L h
-
7/27/2019 Dynamic Loads.pdf
25/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
(1) R-Waves or Rayleigh Waves:These waves produce a circular motion
analogous to the motion of ocean waves.
Hence, rotation along with vertical movements
takes place in case of Rayleigh waves (Fig.).
Movement of Particles in Rayleigh Waves.
P f D Z hid A Siddi i UET L h
-
7/27/2019 Dynamic Loads.pdf
26/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
(2) L-Waves or Love Waves:
These waves produce horizontal motion along theground surface transverse to the direction of
propagation.
Earthquake magnitude and Richter scale
Earthquake magnitude is a measure of the energy
released during an earthquake.
It defines the size of the seismic event but is not
related with damage or effect of earthquake at agiven location.
The magnitude of earthquake is usually measuredon Richter scale, which is a log scale.
P f D Z hid A Siddi i UET L h
-
7/27/2019 Dynamic Loads.pdf
27/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
A magnitude of M5 Richter scale is ten-times
greater than a magnitude of M4 and isassociated with an increase in energy release of
31.6 times.
A magnitude of M5 is 100 times greater than a
magnitude of M3 scale.
Earthquake intensity and Mercalli scale
Intensity is an assessment of the effect of the
earthquake at a given location and is not directlyrelated to the earthquake magnitude.
P f D Z hid A Siddi i UET L h
-
7/27/2019 Dynamic Loads.pdf
28/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
This is determined not by reading instruments butby observing the effects on structures, human life
and disturbance to the ground surface.
Modified Mercalli index is based on the observed
effects of an earthquake at a specific site.
P f D Z hid A Siddi i UET L h
-
7/27/2019 Dynamic Loads.pdf
29/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Total destruction. Waves seen on ground.XII.
Almost all structures fall. Bridges wrecked. Very wide cracks in ground.XI.
Many structures damaged. Ground is badly cracked.X.
All buildings considerably damaged, many shift off at foundations.Noticeable cracks in ground.
IX.
Specially designed structures damaged slightly, others collapse.VIII.
Everyone runs outdoors. Poorly built structures considerably damaged; slight
damage elsewhere.
VII.
Felt by all; many people run outdoors. Furniture moved, slight damage
occurs.
VI.
Felt by nearly everyone; many people awakened. Swaying trees and poles
may be observed.
V.
Felt indoor by many. Feels like a truck has struck the building.IV.
Tremor noticed by many, but they often do not realize it as an earthquake.III.
Felt by very few people.II.
Felt by almost no one.I.
EffectMercalli
Scale
Prof Dr Zahid A Siddiqi UET Lahore
-
7/27/2019 Dynamic Loads.pdf
30/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Main Considerations For Seismic Design
Design of structures to withstand the maximum
intensity earthquake is highly expensive and may
not even be possible due to the following factors:
1. The magnitude, intensity and other
characteristics of future earthquakes are notprecisely known.
2. Stiffer structures attract more earthquakeloads. These structures cannot dissipate
energy and all the energy is stored in them
making them unstable.
Prof Dr Zahid A Siddiqi UET Lahore
-
7/27/2019 Dynamic Loads.pdf
31/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
3. Heavier design means more mass of the
structure. Due to larger mass, moreinertial forces are produced during the
ground excitation.
The most common method to design
earthquake resistant structures is to design for
mild earthquakes of expected commonoccurrence in the elastic range or in the
inelastic range with less or no permanent
deformations.
Ductility is then provided for maximum expected
intensity of earthquakes.
Prof Dr Zahid A Siddiqi UET Lahore
-
7/27/2019 Dynamic Loads.pdf
32/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Ductilityis a measure of inelastic deformationsthat may be produced in a structure before its
collapse.
Inelastic deformations release energy in the form
of heat and make the structure stable.
Permanent deformations may be produced in thestructure with considerable cracking and structure
may not be useable after a severe earthquake.
However, the life is saved as the people may
escape out of the building.
Prof Dr Zahid A Siddiqi UET Lahore
-
7/27/2019 Dynamic Loads.pdf
33/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
In essence the main aim of earthquake resistant
design is to avoid loss of life and then less loss toproperty is the second criterion.
It may be tried that the damage is repairable formoderate earthquakes.
Methods Of Analysis For Earthquake Loading
1 Free Vibration Analysis
2 Response History Analysis (RHA)3 Response Spectrum Analysis (RSA)
4 Equivalent Static orPseudo-Static Load Method
Prof Dr Zahid A Siddiqi UET Lahore
-
7/27/2019 Dynamic Loads.pdf
34/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Related Methods Of Dealing With Earthquakes
1 Base Isolation Method
2 Use Of Special Energy Dissipating Devices
DAMPING
Damping means the presence of frictional forces
in the structure, which transforms the mechanicalenergy of system in to other forms of energy,
such as, heat.
If damping is completely absent in an ideal
system, a structure once excited will oscillate
indefinitely with constant amplitude at its naturalfrequency.
Prof Dr Zahid A Siddiqi UET Lahore
-
7/27/2019 Dynamic Loads.pdf
35/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
The viscous damping forces produced areproportional to the velocity of the piston.
However, the actual damping in a structure may
result from looseness of joints, dry friction between
components (called Coulomb damping), material
damping (or internal damping found by examining
the area within the hysteresis loop between
stresses and acceleration), structural damping
(general term for all types of damping in astructure) and many other complex causes that
would lead to nonlinear behavior of the structure.
Prof Dr Zahid A Siddiqi UET Lahore
-
7/27/2019 Dynamic Loads.pdf
36/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Critical Damping (ccr): It is defined as that
amount of damping due to which a freely excitedsystem does not oscillate but returns to its
original position in the shortest possible time.
Damping Ratio Of System ():
Damping ratio of a system is defined as the ratioof damping present in a system to its critical
damping. = c / ccr.
Citical damping coefficient usually ranges
between 2 to 10% of ccr( = 0.02 to 0.10) for
actual structures.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
37/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
= 1 critically damped response
> 1 over-damped response < 1 under- damped response
EQUIVALENT STATIC LOAD METHOD
The parameters discussed in the following
sub-sections are required to be evaluated toget the values of equivalent static loads
according to UBC-97.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
38/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Seismic Zone Factor (Z)
The zone factor (Z) is given as a factor of peak
acceleration with respect to acceleration due to
gravity (g) and it varies from 0.075 to 0.40.
The suggested values correspond to recurrence
interval of 475 years giving a 10 percentprobability of being exceeded in a 50 years
period.
0.0750.150.200.300.40Effective Peak Ground
Acceleration (EPA)
12A2B34Zone
Table. Seismic Zones and Effective Peak Ground Accelerations.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
39/86
q , ,
Soil Profile Types
The ground vibrations traveling through the soil
may be amplified or reduced depending upon the
fundamental period and type of strata.
UBC classifies soils into six profile types, as
given in Table.
This classification depends on the average shear
wave velocity in the top 30m of material.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
40/86
q , ,
Detailed investigations requiredVery soft clayey soilSF
< 180Soft soilSE
180 to 360Stiff soilSD
360 to 760Soft rockSC
760 to 1500RockSB
> 1500Hard rockSA
Shear Wave Velocity
(m/s)
Description of SoilSoil Profile Type
Table. Soil Profile Types.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
41/86
q , ,
Seismic Source Types
The seismic source types are decided based on
the maximum moment magnitude potential of a
fault and its slip rate per year.Type C represents almost an inactive fault in
Table.
2.0 6.5C
The fault which is not A or CB
5.0 7.0A
Slip Rate (mm/year)Maximum Moment Potential
Source CharacteristicsSeismic Source
Type
Table. Seismic Source Characteristics.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
42/86
q
Near-Source Factors
Two factors, Na and Nv, are used to considerincreased ground motions near a fault.
The factorNa is the acceleration-based factorthat is important for short-period structures and
velocity-based factorNv that is important for
periods exceeding one second.
1.01.01.01.01.21.01.61.3B1.01.01.21.01.61.22.01.5A
Nv
Na
Nv
Na
Nv
Na
Nv
Na
15 km10 km5 km 2 kmDistance From FaultSeismic
Source
Type
Table. Near Source Factors (Na
and Nv) for Various Seismic Source Types.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
43/86
Ground Response Coefficients
The two ground response coefficients, Ca and Cv,
give indication of the vibration amplification
capacity of a soil depending on zone factor (Z), soilprofile factor (S) and the near-source factors (Naand Nv).
The fundamental period of a structure determines
whetherCa orCv is more important for design of a
structure.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
44/86
0.96 Nv
0.36 Na
0.840.360.640.340.500.300.260.19SE
0.64 Nv
0.44 Na
0.540.360.400.280.320.220.180.12SD
0.56 Nv
0.40 Na
0.450.330.320.240.250.180.130.09SC
0.40 Nv
0.40 Na
0.300.300.200.200.150.150.080.08SB
0.32 Nv0.32 Na0.240.240.160.160.120.120.060.06SA
Cv
Ca
Cv
Ca
Cv
Ca
Cv
Ca
Cv
Ca
Zone 4Zone 3Zone 2BZone 2AZone 1Soil
Profile
Table. Ground Response Coefficients, Ca
and Cv
.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
45/86
When soil parameters are unknown, soil profile
type SD may be assumed in seismic zones 3 and 4and profile SEmay be assumed in other zones.
For a regular structure, the near source factor
needs not exceed 1.3.
Fundamental Time Period Of A Structure
The time period of a structure may exactly be
calculated by performing free vibration analysis of
the structure, which involves lengthy calculations.
Following empirical methods are also available to
reasonably guess the fundamental time period ofa structure:
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
46/86
Approximate method
Fundamental time period, T = sec10
storiesofnumber
Method A of UBC
TA =4
3
)( nt hC
wherehn = height of the roof above the base in
meters, not including the height of parapets.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
47/86
Ct = 0.085 for steel moment resisting frames
= 0.073 for reinforced concrete moment
resisting frames and eccentric braced steel
frames
= 0.050 for all other buildings
Method B of UBC
TB =
ii
ii
fg
W
2
2
1.4TA for Zones 1,2 and 3
1.3 TA for Zones 4
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
48/86
where
i = static elastic deflection at level i dueto the forces applied at all levels,
increasing in a linear way with height.
The value of deflection must be withrespect to the base in mm.
= 1floorth-atforcelateraltotal
+ iiki
ki = shear stiffness of columns under floor i
fi = lateral force at level i, N
wi = dead load located at level i, Nand
g = acceleration due to gravity
= 9810 mm/sec
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
49/86
Ductility
Ductility of an element shows its capacity todeform in the inelastic range without collapse.
Due to these inelastic deformations, the energyis dissipated making the structure relatively
stable against earthquake forces.
If these deformations successfully occur in the
two opposite directions causing reversal of
stresses in the members, hysteresis loops areproduced dissipating energy in each cycle of
loading, unloading and loading in the opposite
direction.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
50/86
Response Modification Factor (R)
The response modification factor of a structure (R)
is ratio of the seismic base shear of an elastic
system to a reduced design base shear dependingupon ductility, energy absorbing capacity, increase
in natural period due to yielding and increase in
damping ratio of the structure.
If shear walls or braced frames provide support to
gravity loads and all the lateral loads, the structuralsystem is a Bearing Wall System (BWS). In other
words, the gravity loads are resting on walls.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
51/86
If separate systems are provided to resist lateral and
gravity loads, the structural system is called BuildingFrame System (BFS).
No special detailing is required for gravity load
supporting frames.
Special Moment Resisting Frames (SMRF) are
frames specially detailed to provide high ductility andsupport for lateral and gravity loads by flexural action.
Moment Resisting Frames With Masonry ShearWalls are called MRWFsystems.
Dual Systems are those in which more than one
systems are used together.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
52/86
Many other types given in UBC
None8.59. Concrete shear walls with SMRF
496.58. Masonry MRWF
None8.57. Steel or concrete SMRF
736.46. BFS with steel ordinary braced frames
495.55. BFS with masonry shear walls
735.54. BFS with concrete shear walls
737.03. BFS with steel eccentrically braced frames
494.42. BWS with steel braced frames
494.51. BWS with concrete or masonry shear walls
Height Limit(m)
RStructural System
Table. Response Modification Factor, R.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
53/86
The value of the response modification factor (R) isdetermined from consideration of a structures
over-strength capacity beyond the point at which
the elastic response of the structure is exceeded.
The value ofRalways exceeds unity, which
indicates that all structures are designed for forcesless than would be produced in a completely
elastic structure.
This reduced force level is made possible by the
energy absorption and dissipation capacity of the
structure at displacements in excess of initial yield.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
54/86
Seismic Importance Factor (I)
The factor is equal to 1.25 for essential and
hazardous facilities and 1.00 for special
occupancy, standard occupancy andmiscellaneous structures.
Seismic Response Coefficient (Cs
)
The seismic response coefficient (Cs) is the
fraction of total dead load of the structure that is
acting as base shear on the structure.
This means that the base shear (V) is: V= Cs W.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
55/86
This factor depends upon velocity of acceleration
based ground response coefficient (CvorCa),importance factor (I), response modification factor
(R) and time period (T).
Response time Ts =a
v
C
C
5.2and Ta = 0.2Ts
Cs =RTICv (ifT> Ts) subjected to maximum
and minimum values
Max. value = 2.5 Ca I / R(Controls when T= Ta to Ts)
Min. value = 0.11 Ca I(OR) 0.8ZNvI / Rfor zone-4
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
56/86
Seismic Dead Load (W)
The seismic dead load (W) consists of the
following:
i)Dead load of the structure.
ii)25 percent of the floor live load for storage and
warehouses.
iii)A minimum allowance of 50 kg/m2 for movable
partitions.
iv)The total weight of permanent equipment and
fittings.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
57/86
Magnitude Of Base Shear (V)
1 UBC refined formula
Base shearV = Cs WMaximum inelastic displacement m = 0.7 RsWhere s = the displacement corresponding tothe shear V, given above.
2 UBC simplified formula
Base shearV = (3.0 Ca / R)W
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
58/86
This is a conservative formula having the
following restrictions:
i)Ordinary occupancy type.
ii)Light-frame construction not exceeding 3stories.
iii)Any construction, except bearing wallsystems, but not exceeding two stories.
Distribution Of Base Shear
At Various Story Levels
Shear at a particular story, FX
=
ii
xx
aW
aWV
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
59/86
Where
V = modal base shearWi= seismic dead load at level-i
ai= mode shape component at
level-i for the given modewx= seismic dead load located at
level-x
and ax= mode shape component atlevel-x for the given mode
For uniform distribution of mass over height and
for first linear mode, the distribution of base
shear may be simplified as follows:
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
60/86
FX
=
iixx
hW
hWV
1
Where V1 = base shear corresponding to first
mode
hi = height above the base to level-i
and hx
= height above the base to level-x
In order to account for higher mode effects in the
above expression for long period buildings, anadditional force Ft is added at the top of the
structure.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
61/86
Ft
= 0.07 T V when T> 0.7 sec
Where V= total base shear
= Ft+ Fx
In such cases: FX =
ii
xxt
hW
hWFV )(
RESPONSE SPECTRUM ANALYSIS (RSA)
Spectral response means the maximumdisplacement, velocity or acceleration response.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
62/86
Pseudo-Acceleration is the maximum
displacement of the structure multiplied withsquare of natural circular frequency.
Pseudo-Velocityis the maximum displacementof the structure during an earthquake multiplied
with the natural circular frequency.
Sd = spectral displacement
Sv = spectral velocity
= Sd
Sa = spectral acceleration
= Sv = 2 Sd
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
63/86
Because of this inter-relationship, all three spectra
may be plotted on the same graph using tripartiteaxes and logarithmic scales.
A response curve orresponse spectrum is agraph of the spectral (or maximum) response of a
range of single-degree-of-freedom oscillators to a
specified ground motion, plotted against thefrequency or period of the oscillators.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
64/86
1,000
500
200
100
50
20
10
0.0550
0.10 0.20 0.50 1 52 10Time Period, sec (on log scale)
Spectral Velocity
(Sv), mm/sec (on
log scale)
= 0 % = 2 % = 5 %
= 10 %
A Typical Out-of-Scale Response Spectrum.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Procedure To Use Response
-
7/27/2019 Dynamic Loads.pdf
65/86
Procedure To Use Response
Spectra For SDOF Systems
The procedure to use response spectrum to calculate
the earthquake lateral forces for single degree of
freedom systems is summarized as under:
i) Calculate angular speed and time period T
for the structure.
ii) Estimate the damping ratio, .
iii) Use applicable response spectrum for aparticular area and find SdorSvorSa (the
values are inter-convertible) against the time
period.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
66/86
iv) Find shear force in each column as:
S.F = Sd k
v) Find the total lateral force by adding shear
forces in all the columns.
Procedure To Use Response
Spectra For MDOF Systems
The procedure to use response spectrum for the
calculation of the earthquake lateral forces incase of multiple degrees of freedom systems is
summarized as under:
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
67/86
1. Calculate angular speed and time period T
for the desired mode of vibration of the structure.
2. Find the mode shape ai.
3. Estimate the damping ratio .
4. Find Sd, Sv and Sa from the response
spectrum or calculate others after knowing oneout of these.
5. Calculate the effective weight as follows:
WE =( )( )
2
2
ii
ii
aW
aW
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
68/86
iiii
aW
aWV
6. Calculate the base shear as follows:
V = WESa / g
7. Find the lateral force at each level as follows:
Fi =
Example : Determine the base shear for the
fundamental mode with = 0.05. Also determine
the lateral load at each level for the fundamentalmode.
= 15.1 rad/sec
=86.295.1
00.1
ia
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
69/86
Frame For Example.
880 kg/m2
880 kg/m2
590 kg/m2
30m 30m
1
3
2
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
70/86
Solution:Dead Loads:
Level 1 & 3 = (880)(30)(30) = 7770 kN
Level 2 = (590)(30)(30) = 5209 kN
= 15.1 rad/sec
T = 2 / = 0.416 sec
From the response spectrum, Sv = 350 mm/sec
Sa = Sv = 5285 mm/sec2 = 5.285 m/sec2
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
71/86
The calculations are made in Table using the
following expressions:
( )
( )
2
2
ii
ii
aW
aW
ii
ii
aW
aWV
WE =
V = WESa / g and Fi =
9530911324015020749Total527563555222222.8677703
241119807101581.9552092
1844777077701.0077701kNkN-mm
2
kN-mmmmkN
Fi
Wiai
2Wiai
ai
Wi
Level
Table. Calculation Sheet For Example.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
( )2
-
7/27/2019 Dynamic Loads.pdf
72/86
( )
( )91132
401502
81.9
285.517689
WE =
= 17689 kN
= 9530 kNV =
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
73/86
UBC RESPONSE
SPECTRUM METHOD
UBC Design Response Spectrum is an elasticresponse spectrum for 5 percent equivalent
viscous damping used to represent the dynamic
effects of the Design Basis Ground Motion forthe design of structures.
This response spectrum may be developed for a
site-specific spectrum based on geologic,
tectonic, seismological and soil characteristics
associated with a specific site.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
74/86
Alternatively, the spectrum constructed inaccordance with the spectral shape given in UBC
using the site-specific values ofCa and Cvand
multiplied by the acceleration of gravity, 9.815m/sec.2.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
75/86
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
According to UBC 1633 the following
-
7/27/2019 Dynamic Loads.pdf
76/86
According to UBC 1633, the following
requirements must be satisfied:
1. Only the elements of the designated
seismic-force-resisting system need to be
used to resist design forces.
2. The individual components should be
designed to resist the prescribed designseismic forces acting on them.
3. All building components in Seismic Zones
2, 3 and 4 shall be designed to resist the
effects of the calculated seismic forces and
the effects of gravity loadings from dead,floor live and snow loads.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
77/86
4. Consideration shall be given to design for
uplift effects caused by seismic loads.
5. In Seismic Zones 2, 3 and 4, provision should
be made for the effects of earthquake forcesacting in a direction other than principal axes.
6. If the axial load in the column due to seismic
forces acting in either direction is less than 20 %
of the column capacity, the orthogonal effects
may simply be considered by designing for 100% of the design seismic forces in one direction
plus 30 % of the design seismic forces in the
perpendicular direction.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
78/86
7. The combination requiring the greater
component strength should be used for design.
8. Alternatively, the effects of the two orthogonal
directions may be combined on a square root ofthe sum of the squares (SRSS) basis.
9. When the SRSS method of combining
directional effects is used, each term computed
shall be assigned the sign that will result in the
most conservative result.10. The strength and stiffness of the framing
between the base and the foundation shall not
be less than that of the superstructure.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
79/86
According to UBC 1633.2.7, concrete frames
that are part of the lateral-force-resisting
system should conform to the following:1. Should be special moment-resisting
frames in Seismic Zones 3 and 4.
2. Should be a minimum of intermediate
moment-resisting frames in Seismic
Zone 2.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
80/86
According to UBC 1631.4.1, response spectrumanalysis is defined as an elastic dynamic analysis
of a structure utilizing the peak dynamic response
of all modes having a significant contribution tototal structural response.
Peak modal responses are calculated using theordinates of the appropriate response spectrum
curve which correspond to the modal periods.
Maximum modal contributions are combined in astatistical manner to obtain an approximate total
structural response.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
81/86
This condition is considered satisfied by
demonstrating that for the modes considered, at
least 90 percent of the participating mass of the
structure is included in the calculation of responsefor each principal horizontal direction.
The peak member forces, displacements, story
forces, story shears and base reactions for eachmode should be combined by recognized methods.
When three-dimensional models are used foranalysis, modal interaction effects shall be
considered when combining modal maxima.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
Reduction of Loads Based On Ductility
-
7/27/2019 Dynamic Loads.pdf
82/86
According to UBC 1631.5.4, the Elastic
Response Parameters may be reduced for
purposes of design in accordance with thefollowing items, with the limitation that that the
corresponding design base-shear should not be
less than the Elastic Response Base Sheardivided by the value ofR.
The corresponding reduced design seismicforces shall be used for design.
Reduction of Loads Based On Ductility
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
83/86
1. For all regular structures where the ground
motion representation complies with Ground
Motion definition of UBC using designspectrum, Elastic Response Parameters
may be reduced such that the corresponding
design base shear is not less than 90percent of the base shear determined in
accordance with Static Force Procedure.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
84/86
2. For all regular structures where the ground
motion representation complies with Ground
Motion definition of UBC using site-specific designspectrum, Elastic Response Parameters may be
reduced such that the corresponding design base
shear is not less than 80 percent of the base
shear determined in accordance with Static Force
Procedure.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
85/86
3. For all irregular structures, regardless of the
ground motion representation, ElasticResponse Parameters may be reduced such
that the corresponding design base shear is
not less than 100 percent of the base sheardetermined in accordance with Static Force
Procedure.
Prof. Dr. Zahid A. Siddiqi, UET, Lahore.
-
7/27/2019 Dynamic Loads.pdf
86/86
4. The vertical component of ground motion may
be defined by scaling corresponding horizontal
accelerations by a factor of two-thirds.Alternative factors may be used when
substantiated by site specific data. Where the
Near Source Factor, Na, is greater than 1.0,
site-specific vertical response spectra should be
used in place of the factor of two-thirds.
top related