Replacement AB DE-ION® Circuit Breakers
Product Focus 2010
Eaton’s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton’s full-scale engineering services, these products provide customer-driven PowerChain Management® solutions to serve the power system needs of the data centre, industrial, institutional, public sector, utility, commercial, residen-tial, IT, mission critical, alternative energy and OEM markets worldwide.
PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eatoncanada.ca
Replacement Circuit Breakers Cover 2010.indd 1 8/19/10 6:17:08 PM
Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
1
494949494949494949494949494949494949494949494949494949494949
Replacement AB DE-ION® Circuit Breakers
For Lighting, Distribution and Power Circuits
All Cutler-Hammer
®
Moulded Case Circuit Breakers are built to meet requirements of NEMA Standard AB-1-1993.
Ordering Information
AB De-ion
�
circuit breakers are to be ordered as follows:
Fixed Trip Breakers
Order complete breaker or complete breaker less terminals plus required terminals.
Interchangeable Trip Breakers
Order frame, trip unit and terminals.
When Ordering, Specify:
Catalogue Number or Style Number, Quantity.
List Prices
To obtain list prices of breakers, modifications and accessories, locate style or catalogue number from appropriate page of Selection Data and refer to current PAD (Price and Availability Digest).
Where mounting hardware is desired, specify quantity and style number. No charge when ordered with complete breaker.
If breakers are to be modified, order “similar to” a standard catalogue number, and describe the special features desired.
Available accessories are listed beginning on page 39. In some cases, accessories are listed for sale in quantity lots. In these instances, order item in quantity lots indicated.
Further Information:AB De-ion
�
Circuit Breakers
Application Data 29-168Time/Current Characteristic Curves
Dimension Sheet 29-171
Index
Breaker Page
Standard Breakers 100 and 150 Amperes
Types EB, EHB, FB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2, 3LFB Current Limiter for Type FB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Type LC, LCA, LCG, LCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25
225 AmperesTypes JA, KA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6, 7Types CA, CAH, HCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
250 AmperesTypes JB, KB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 5
300 AmperesTypes LC, LCA, LCG, LCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25
400 AmperesType DA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Types LBB, LB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 11Types LAB, LA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 - 15Types LC, LCA, LCG, LCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25
600 AmperesTypes LA, LAY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16, 17Types LC, LCA, LCC, LCCA, LCG, LCGA, LCCG, LCCGA, LCY,
LCYA, LCYG, LCYGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 - 26800 Amperes
Types MA, MAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 19Types MC, MCC, MCA, MCCA, MCG, MCCG, MCGA, MCCGA,
MCY, MCYA, MCYG, MCYGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 - 291200 Amperes
Types NB, NBY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 21Types NC, NCA, NCG, NCGA, NCY, NCYA, NCYG, NCYGA . . . . . . . . . . . . . 30, 31
2500 AmperesTypes PB, PBF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 23
3000 AmperesTypes PC, PCA, PCC, PCCA, PCG, PCGA, PCCG, PCCGA . . . . . . . . . . . . . . 32, 33
MARK 75
®
High Interrupting Capacity Breakers150 Amperes
Type HFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2, 3Types HLC, HLCA, HLCG, HLCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25
225 AmperesType HKA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
250 AmperesType HKB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
300 AmperesTypes HLC, HLCA, HLCG, HLCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25
400 AmperesType HLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10, 11Type HLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14, 15Types HLC, HLCA, HLCG, HLCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25
600 AmperesType HLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Types HLC, HLCA, HLCC, HLCCA, HLCG, HLCGA, HLCCG, HLCCGA . . . . 24, 25
800 AmperesType HMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Types HMC, HMCC, HMCA, HMCCA, HMCG, HMCCG,
HMCGA, HMCCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27, 281200 Amperes
Type HNB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Types HNC, HNCA, HNCG, HNCGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Seltronic™ Breaker Rating Plug Selection Data . . . . . . . . . . . . . . . . . . . . . . . . . 34Seltronic™ Breaker External Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Moulded Case Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36, 37Motor Circuit Protector
MCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38EL Limiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38MCP Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 - 49Panelboard Replacement Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 - 56Motor Control Centre Replacement Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . 57 - 60
2 Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
�
DC ratings apply to substantially non-inductive circuits.
�
Not listed with CSA and Underwriters Laboratories Inc.
�
Switching duty rated for 120 volts AC fluorescent light applications only.
�
Switching duty rated for 277 volts AC fluorescent light applications only.
�
15 thru 30 amp ratings only have 75,000 amp I.C. 40 thru 100 amp ratings have 30,000 amp Asym., 25,000 Sym. I.C.
�
Two pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.
�
Ratings above 10,000 Amps not CSA and UL Listed.
Replacement AB DE-ION® Circuit Breakers
Types, EB, EHB, FB, HFB
EB: 120, 240 Volts AC; 125/250 Volts DCEHB: 277, 480 Volts AC; 250 Volts DCFB, HFB: 600 Volts AC, 250 Volts DC
Listed with CSA and Underwriters Laboratories Inc. except as noted.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings.
List Prices:
See PAD (Price and Availabil-ity Digest)
Accessories and Modifications
Description: Pages 39 - 49
Max Volts Amperes
EB Breakers
120 and 240 AC125/250 DC
10,000 Asym., Sym. 5,000
➀
EHB, FB Breakers
240 AC277 AC (EHB)480 AC600 AC (FB)250 DC
20,000 Asym., 18,000 Sym.15,000 Asym., 14,000 Sym.15,000 Asym., 14,000 Sym.15,000 Asym., 14,000 Sym.10,000
➀
MARK 75 Type HFB
240 AC277 AC
➄
480 AC600 AC250 DC (2 Pole)
75,000 Asym., 65,000 Sym.75,000 Asym., 65,000 Sym.30,000 Asym., 25,000 Sym.20,000 Asym., 18,000 Sym.20,000
➀➆
Type EB 1, 2, 3 Poles; 240 Volts AC Max.; Thermal Magnetic and Saf-T-Vue® Breakers (Includes Load Terminals Only; see Terminals page 3) Suitable for Reverse Feed Application
Continuous AmpereRatingat 40°C
1-Pole, 120 Volts AC,125 Volts DC
➀
2-Pole, 240 Volts AC,125/250 Volts DC
➀
3-Pole, 240 Volts AC,125/250 Volts DC
➀
Standard Standard Standard Saf-T-Vue
➁
Catalogue Numbers
15 20 25 30 35 40 45 50 60 70 80 90100
EB1015
➂
EB1020
➂
EB1025EB1030EB1035EB1040EB1045EB1050EB1060EB1070EB1080EB1090EB1100
EB2015EB2020EB2025EB2030EB2035EB2040EB2045EB2050EB2060EB2070EB2080EB2090EB2100
EB3015EB3020EB3025EB3030EB3035EB3040EB3045EB3050EB3060EB3070EB3080EB3090EB3100
EB3015SEB3020SEB3025SEB3030SEB3035SEB3040SEB3045SEB3050SEB3060SEB3070SEB3080SEB3090SEB3100S
Approx. Ship. Wt.: 2 lbs. Approx. Ship. Wt.: 3 lbs. Approx. Ship. Wt.: 4
1
⁄
2
lbs.
Type EHB 1, 2, 3 Poles; 480 Volts AC Max.; Thermal Magnetic and Saf-T-Vue® Breakers (Includes Load Terminals Only; see Terminals page 3) Suitable for Reverse Feed Application
Continuous AmpereRatingat 40°C
1-Pole, 277 Volts AC,125 Volts DC
➀
2-Pole, 480 Volts AC,250 Volts DC
➀
3-Pole480 Volts AC
Standard Standard Standard Saf-T-Vue
➁
Catalogue Numbers
15 20 25 30 35 40 45 50 60 70 80 90100
EHB1015
➃
EHB1020
➃
EHB1025EHB1030EHB1035EHB1040EHB1045EHB1050EHB1060EHB1070EHB1080EHB1090EHB1100
EHB2015EHB2020EHB2025EHB2030EHB2035EHB2040EHB2045EHB2050EHB2060EHB2070EHB2080EHB2090EHB2100
EHB3015EHB3020EHB3025EHB3030EHB3035EHB3040EHB3045EHB3050EHB3060EHB3070EHB3080EHB3090EHB3100
EHB3015SEHB3020SEHB3025SEHB3030SEHB3035SEHB3040SEHB3045SEHB3050SEHB3060SEHB3070SEHB3080SEHB3090SEHB3100S
Approx. Ship Wt.: 2 lbs. Approx. Ship. Wt.: 3 lbs. Approx. Ship. Wt.: 4
1
⁄
2
lbs.
Type FB, HFB 1, 2, 3, 4 Poles; 600 Volts AC Max.; Thermal Magnetic MARK 75® Saf-T-Vue® Breakers (Includes Load Terminals Only; see Terminals, page 3) Suitable for Reverse Feed Application
Continuous AmpereRatingat 40°C
1-Pole277 Volts AC125 Volts DC
➀
2-Pole600 Volts AC250 Volts DC
➀
3-Pole600 Volts AC
4-Pole
➁
600 Volts ACMARK 75
➄
Standard MARK 75
➅
Standard Saf-T-Vue
➅
MARK 75 StandardCatalogue Numbers
15 20 25 30 35 40 45 50 60 70 80 90100110125150
HFB1015
➃
HFB1020
➃
HFB1025HFB1030HFB1035HFB1040HFB1045HFB1050HFB1060HFB1070HFB1080HFB1090HFB1100
FB2015FB2020FB2025FB2030FB2035FB2040FB2045FB2050FB2060FB2070FB2080FB2090FB2100
HFB2015HFB2020HFB2025HFB2030HFB2035HFB2040HFB2045HFB2050HFB2060HFB2070HFB2080HFB2090HFB2100
FB3015FB3020FB3025FB3030FB3035FB3040FB3045FB3050FB3060FB3070FB3080FB3090FB3100FB3110FB3125FB3150
FB3015SFB3020SFB3025SFB3030SFB3035SFB3040SFB3045SFB3050SFB3060SFB3070SFB3080SFB3090SFB3100SFB3110SFB3125SFB3150S
HFB3015LHFB3020LHFB3025LHFB3030LHFB3035LHFB3040LHFB3045LHFB3050LHFB3060LHFB3070LHFB3080LHFB3090LHFB3100LHFB3110LHFB3125LHFB3150L
FB4015FB4020FB4025FB4030FB4035FB4040FB4045FB4050FB4060FB4070FB4080FB4090FB4100
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
3
494949494949494949494949494949494949494949494949494949494949
Replacement AB DE-ION ® Circuit Breakers
Types, EB, EHB, FB, HFB
Special Breakers
➀
Type FB, Magnetic Only, Front Adjustable Breakers (Includes Line and Load Terminals)
ContinuousAmpereRating
MagneticTrip RangeAmperes
2-Pole
➁➂
, 600 Volts AC 3-Pole, 600 Volts ACStandard MARK 75
�
Standard Saf-T-Vue
�
MARK 75
�
Catalogue/Style Numbers
3 5 10 25 25 30 30 50 50 70100100150
7- 22 15- 45 35- 110 32- 80 66- 190 50- 150 90- 270 66- 190160- 480100- 270150- 480450-1550575-1800
FB2022MRLFB2045MRLFB2110MRL2610D53G12FB2190MRL1268C14G05FB2270MRL1268C14G01FB2480MRL2610D53G131268C14G03FB21550MRLFB21800MRL
HFB2022MLHFB2045MLHFB2110ML4994D96G12HFB2190ML
HFB2270ML
HFB2480ML4994D96G13
HFB21550MLHFB21800ML
FB3022MRLFB3045MRLFB3110MRL2610D53G30FB3190MRL1268C14G06FB3270MRL1268C14G02FB3480MRL2610D53G311268C14G04FB31550MRLFB31800MRL
FB3022SMRLFB3045SMRLFB3110SMRL4998D89G30FB3190SMRL
FB3270SMRL
FB3480SMRL4998D89G31
FB31550SMRLFB31800SMRL
HFB3022MLHFB3045MLHFB3110ML
HFB3190ML
HFB3270ML
HFB3480ML
HFB31550ML
Breaker Rating,Amperes
LimiterCatalogue Number
For Thermal Magnetic Breakers
➇
15-7080-150
LFB3070RLFB3150R
For Magnetic Only Breakers
➇
3 5 10 25 30 50 70100150
LFB3003MRLFB3005MRLFB3010MRLFB3025MRLFB3030MRLFB3050MRLFB3070MRLFB3100MRLFB3150MR
LFB Current Limiter Attachment
➆
The LFB Current Limiter is an attachment that bolts to the load end of a standard FB thermal magnetic or magnetic only breaker, providing 200,000 Amps interrupting capacity at up to 600 volts AC (no DC rating). Limiters for thermal magnetic breakers are listed with CSA and Underwriters Laboratories Inc. for the above. Current limiters must be applied as indicated in the table.
Standard LFB terminals are suitable for Cu/AI cable. Ratings thru 70 Amps accept (1) #14-#2, and 100 and 150 amp accept (1) #1-4/0.
➇
50°C Calibration
➀
Add suffix “V” to catalogue number for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Ambient Compensating Breakers
➀
To order, add suffix letter “A” to standard thermal magnetic breaker catalogue number.
Available in all standard ratings of EB, EHB, FB and HFB breakers up to ratings of 100 Amps. Add 10% to price of standard breaker.
Further Information
List Prices: See PAD (Price and Availability Digest)
Application, Operating Characteristics:
AD 29-160
Dimensions:
DS 29-171
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagneticFrequency
Add 10% toList Price ofComplete Breaker
NoneNoneNone
Special Calibrations
➀
Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See Application Data 29-160 for information regarding special conditions. Maximum calibration for 400 Hz. is 135 Amps.
Screw
Wire Clamp
Conductor
Clip
Extrusion
ConductorConductorConductor
CollarCollarCollar
ScrewScrew
WasherWasher
Nut
Terminals
Breakers include load terminals only
➃➄
.Terminals are CSA and Underwriters Laboratories Inc. listed as suitable for wire type and size as listed below. When used with aluminum conductors, use joint compound. When line terminals are required, order by style number.
Style 624B100G02
Insert collar enclosing conductor as shown. Locate nut on top of conductor and tighten securely with screw and washer. Caution: Collar must surround conductor.
Style 624B100G10
Assemble collar on top of conductor as shown. Tighten securely with screw and washer.
Style 624B100G17
Insert collar enclosing conductor and centre on extrusion on collar. Install clip with legs on top of conductor and snap end around bottom of collar.
Style 624B100G14
Assemble wire clamp to bottom of conductor as shown.
�
Not listed with CSA and Underwriters Laboratories Inc.
�
2-Pole magnetic only breakers supplied in 3-Pole frame with current carrying parts omitted from centre pole.
�
Magnetic only breakers for DC applications require special calibration. Order by description.
�
Magnetic-only breakers include both line and load terminals.
�
Suffix “L” on catalogue number indicates line and load terminals included. If factory installation is required, specify on order.
�
Style listed is for package of 3 terminals. Order quantity equal to
1
⁄
3
total terminals required.
�
Cannot be used with plug-in adapters.
Ratings through 70 Amps can be supplied with terminals for Cu cable only (#14-#2). Order by description.
Shaded gray areas denotes obsolete or discontinued products and services
MaximumBreakerAmps
WireType
WireRange
Package of 3 LineTerminals
➅
Style Number
Standard Pressure Type Terminals
20 (EB, EHB)100150
Al/CuAl/CuAl/Cu
#14-#10#14-1/0# 4-4/0
624B100G14624B100G02624B100G17
Optional Al/Cu Pressure Terminals
50100
Al/CuAl/Cu
#14-#4# 4-4/0
624B100G10624B100G17
4 Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Special Calibrations
➁
Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. For frequencies other than 0-60 Hertz AC, refer to Eaton. Ambient compensating and 400 Hz breakers are not available.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Terminals
➀
Two terminals are required per pole.Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum conductors, use joint compound. To order optional copper only terminals, add suffix “C” to complete breaker catalogue number.
Magnetic Only Breakers
For description, refer to AD 29-160. To order these breakers, select catalogue number from table at left, plus terminals above.
List Prices:
See PAD (Price and Availability Digest)
Accessories and Modifications
Description: Pages 39 - 49
Max Volts Amperes
240 AC480 AC600 AC250 DC
30,000 Asym., 25,000 Sym.25,000 Asym., 22,000 Sym.15,000 Asym., 14,000 Sym.10,000
MaximumBreaker,Amps
TerminalCatalogueNumber
Wire Range, TypeNo. of Cables
Standard Al/Cu Pressure Terminals
TA250KB 1 #4-350 MCM Al/Cu
250 T250KB 1 #4-350 MCM Cu
�
Terminals are shipped separately from breaker frame.
�
Not listed with CSA and Underwriters Laboratories Inc.
�
2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.
�
Select desired terminal from table and order as separate item.
Replacement AB DE-ION ® Circuit Breakers
Types JB, KB, MARK 75
�
Type HKB
Shaded gray areas denotes obsolete or discontinued products and services
Type JB Breakers
90-250 Amperes, 600 Volts AC, 250 Volts DC, 2 and 3 Poles, Fixed Trip Thermal Magnetic, and Saf-T-Vue® Breakers.
Suitable for reverse feed application.
ContinuousAmpereRatingat 40°C
Magnetic Trip Setting,Amperes (Set on HighSide, Adjustable toLower Limits)
Complete Breaker
Includes Pressure Type Aluminum Terminals
➀
Breaker Without Terminals
Standard Saf-T-Vue
➁
Standard Saf-T-Vue
➁
Low High Catalogue Numbers
2 Poles, 600 Volts AC, 250 Volts DC
➂
90100125150175200225250
450 500 625 750 875100011251250
9001000125015001750200022502500
JB2090JB2100JB2125JB2150JB2175JB2200JB2225JB2250
JB2090SJB2100SJB2125SJB2150SJB2175SJB2200SJB2225SJB2250S
JB2090WJB2100WJB2125WJB2150WJB2175WJB2200WJB2225WJB2250W
JB2090SWJB2100SWJB2125SWJB2150SWJB2175SWJB2200SWJB2225SWJB2250SW
Approx. Ship. Wt. 12 Lbs. Approx. Ship. Wt. 12 Lbs.
3 Poles, 600 Volts AC Only
90100125150175200225250
450 500 625 750 875100011251250
9001000125015001750200022502500
JB3090JB3100JB3125JB3150JB3175JB3200JB3225JB3250
JB3090SJB3100SJB3125SJB3150SJB3175SJB3200SJB3225SJB3250S
JB3090WJB3100WJB3125WJB3150WJB3175WJB3200WJB3225WJB3250W
JB3090SWJB3100SWJB3125SWJB3150SWJB3175SWJB3200SWJB3225SWJB3250SW
Approx. Ship. Wt. 14 Lbs. Approx. Ship. Wt. 12 Lbs.
Magnetic Only Breakers, Front Adjustable
➁
ContinuousAmpereRatingat 40°C
Magnetic Trip Setting, Amperes (Set on High Side, Adjustable toLower Limits)
Breaker Only, No Terminals
➃
2 Poles
➂
3 Poles
Standard Saf-T-Vue Standard Saf-T-VueLow High Catalogue Numbers
250250250250250
625 750 87511251250
12501500175022502500
JB21250MWJB21500MWJB21750MWJB22250MWJB22500MW
JB21250SMWJB21500SMWJB21750SMWJB22250SMWJB22500SMW
JB31250MWJB31500MWJB31750MWJB32250MWJB32500MW
JB31250SMWJB31500SMWJB31750SMWJB32250SMWJB32500SMW
50°C Calibration
➁
Add suffix “V” to catalogue number for complete breaker when ordering listed ampere ratings to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagnetic
Add 10% toList Price ofComplete Breaker
NoneNoneNone
Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
5
494949494949494949494949494949494949494949494949494949494949
Listed with CSA and UnderwritersLaboratories Inc. except as noted.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Terminals➁Two required per pole. Select from table on page 4.
Magnetic Only BreakersFor description, refer to AD 29-160. To order these breakers, select frame, trip unit and terminals.
List Prices: See PAD (Price and Availability Digest)
Accessories and Modifications Description: Pages 39 - 49
Max Volts AmperesStandard Breakers
240 AC480 AC600 AC250 DC
30,000 Asym., 25,000 Sym.25,000 Asym., 22,000 Sym.15,000 Asym., 14,000 Sym.10,000
MARK 75® Breakers
240 AC480 AC600 AC250 DC
75,000 Asym., 65,000 Sym.30,000 Asym., 25,000 Sym.20,000 Asym., 18,000 Sym.20,000➄
Type KB and MARK 75� Type HKB Breakers
90-250 Amperes, 600 Volts AC, 250 Volts DC, 2 and 3 Poles, Interchangeable Trip Thermal Magnetic, Saf-T-Vue� Breakers
Contin-uousAmpereRatingat 40°C
Magnetic Trip SettingAmperes➀
Complete Breaker Shipped as Frame, Trip Unit and Terminals➁
Includes Pressure Type Aluminum Terminals➁ Frame Only Trip Unit Only
StandardSaf-T-Vue➂ MARK 75 Standard
Saf-T-Vue➂ MARK 75
StandardSaf-T-Vue,MARK 75
Low High Catalogue Numbers2 Poles, 600 Volts AC, 250 Volts DC➃
90100125150175200225250
450 500 625 750 875100011251250
9001000125015001750200022502500
KB2090KB2100KB2125KB2150KB2175KB2200KB2225KB2250
KB2090SKB2100SKB2125SKB2150SKB2175SKB2200SKB2225SKB2250S
HKB2090HKB2100HKB2125HKB2150HKB2175HKB2200HKB2225HKB2250
KB2250FKB2250FKB2250FKB2250FKB2250FKB2250FKB2250FKB2250F
KB2250FSKB2250FSKB2250FSKB2250FSKB2250FSKB2250FSKB2250FSKB2250FS
HKB2250FHKB2250FHKB2250FHKB2250FHKB2250FHKB2250FHKB2250FHKB2250F
HKB2090THKB2100THKB2125THKB2150THKB2175THKB2200THKB2225THKB2250T
Approx. Ship. Wt. 12 Lbs. Approx. Ship. Wt. 9 Lbs. Approx. Ship. Wt. 2 Lbs.
3 Poles, 600 Volts AC Only
90100125150175200225250
450 500 625 750 875100011251250
9001000125015001750200022502500
KB3090KB3100KB3125KB3150KB3175KB3200KB3225KB3250
KB3090SKB3100SKB3125SKB3150SKB3175SKB3200SKB3225SKB3250S
HKB3090HKB3100HKB3125HKB3150HKB3175HKB3200HKB3225HKB3250
KB3250FKB3250FKB3250FKB3250FKB3250FKB3250FKB3250FKB3250F
KB3250FSKB3250FSKB3250FSKB3250FSKB3250FSKB3250FSKB3250FSKB3250FS
HKB3250FHKB3250FHKB3250FHKB3250FHKB3250FHKB3250FHKB3250FHKB3250F
HKB3090THKB3100THKB3125THKB3150THKB3175THKB3200THKB3225THKB3250T
Approx. Ship. Wt. 14 Lbs. Approx. Ship. Wt. 11 Lbs. Approx. Ship. Wt. 2 Lbs.
Magnetic Only, Front Adjustable Breakers➂
Contin-uousAmpereRating
Magnetic Trip SettingAmperes➀
Trip Units Only
2 Poles➃ 3 PolesLow High Catalogue Numbers
250250250250250
625 750 87511251250
12501500175022502500
HKB21250TMHKB21500TMHKB21750TMHKB22250TMHKB22500TM
HKB31250TMHKB31500TMHKB31750TMHKB32250TMHKB32500TM
� Set on high side, adjustable to lower limit.� Terminals shipped separately from breaker frame.� Not listed with CSA and Underwriters Laboratories Inc.� 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Ratings above 10,000 Amps not CSA and UL listed.
Replacement AB DE-ION ® Circuit Breakers
Types JB, KB, MARK 75� Type HKB
Shaded gray areas denotes obsolete or discontinued products and services
Special Calibrations➂Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. For frequencies other than 0-60 Hertz AC, refer to Eaton. Ambient compensating and 400 Hz breakers not available.
50°C Calibration➂Add suffix “V” to catalogue number for complete breaker, listed above, when ordering listed ampere ratings to be used in 50°C ambients. Same price as standard 40°C breakers.
TypeCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagnetic
Add 30% toList Price ofTrip Unit
NoneNoneNone
6 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Terminals➀
Two terminals are required per pole.
Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum conductors, use joint compound. To order optional copper only terminals, add suffix “C” to complete breaker catalogue number.
Magnetic Only and Ambient Compensating BreakersFor description, refer to AD 29-160. To order, select catalogue number from table at left.
Accessories and Modifications Description: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Max. Volts Amperes240 AC480 AC600 AC250 DC
30,000 Asym., 25,000 Sym.25,000 Asym., 22,000 Sym.25,000 Asym., 22,000 Sym.10,000
BreakerRating,Amps.
CatalogueNumber
Wire Range, TypeNo. of Cables
Standard Al/Cu Pressure Terminals
70-225 TA225LA1 1 #6-350 MCM Cu, or1 #4-350 MCM Al
Optional Pressure Terminals (Copper Only)
70-22570-225➄
T225LAT225LBF
1 #6-350 MCM1 #6-250 MCM
� Terminals are shipped separately from breaker frame.� 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Not listed with CSA and Underwriters Laboratories Inc.� Select desired terminal from table and order as separate item.� Optional terminal.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types JA, KA, MARK 75� Type HKA
Type JA Thermal Magnetic, Saf-T-Vue� Breakers 70-225 Amperes, 600 Volts AC, 250 Volts DC, 2 and 3 Poles, Fixed Trip. Suitable for reverse feed application.
ContinuousAmpereRatingat 40°C
Magnetic Trip Setting,Amperes (Set on HighSide, Adjustable toLower Limits)
Complete Breaker
Includes Pressure Type Aluminum Terminals➀ Breaker Without Terminals
Standard Saf-T-Vue Standard Saf-T-VueLow High Catalogue Numbers
2 Poles, 600 Volts AC, 250 Volts DC➁
70 90100125150175200225
350 450 500 625 750 87510001125
700 900100012501500175020002250
JA2070JA2090JA2100JA2125JA2150JA2175JA2200JA2225
JA2070SJA2090SJA2100SJA2125SJA2150SJA2175SJA2200SJA2225S
JA2070WJA2090WJA2100WJA2125WJA2150WJA2175WJA2200WJA2225W
JA2070SWJA2090SWJA2100SWJA2125SWJA2150SWJA2175SWJA2200SWJA2225SW
Approx. Ship. Wt. 12 Lbs. Approx. Ship. Wt. 12 Lbs.
3 Poles, 600 Volts AC Only
70 90100125150175200225
350 450 500 625 750 87510001125
700 900100012501500175020002250
JA3070JA3090JA3100JA3125JA3150JA3175JA3200JA3225
JA3070SJA3090SJA3100SJA3125SJA3150SJA3175SJA3200SJA3225S
JA3070WJA3090WJA3100WJA3125WJA3150WJA3175WJA3200WJA3225W
JA3070SWJA3090SWJA3100SWJA3125SWJA3150SWJA3175SWJA3200SWJA3225SW
Approx. Ship. Wt. 14 Lbs. Approx. Ship. Wt. 12 Lbs.
Special Breakers➂
ContinuousAmpereRatingat 40°C
Magnetic Trip Setting,Amperes (Set on HighSide, Adjustable toLower Limits)
2 Poles➁ 3 Poles
Standard Saf-T-Vue Standard Saf-T-VueLow High Catalogue Numbers
Magnetic Only Breakers, Front Adjustable – Without Terminals➃
225225225225225
350 625 750 8751125
7001250150017502250
JA2700MWJA21250MWJA21500MWJA21750MWJA22250MW
JA2700SMWJA21250SMWJA21500SMWJA21750SMWJA22250SMW
JA3700MWJA31250MWJA31500MWJA31750MWJA32250MW
JA3700SMWJA31250SMWJA31500SMWJA31750SMWJA32250SMW
Ambient Compensating Breakers
70100125150175200225
350 500 625 750 87510001125
700100012501500175020002250
JA2070AJA2100AJA2125AJA2150AJA2175AJA2200AJA2225A
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
JA3070AJA3100AJA3125AJA3150AJA3175AJA3200AJA3225A
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
50°C Calibration➂Add suffix “V” to catalogue number for complete breaker when ordering listed ampere ratings to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagneticFrequency
Add 10% toList Price ofComplete Breaker
NoneNoneNone
Special Calibrations➂Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also Price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See AD 29-160 for information regarding special conditions.
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 7
494949494949494949494949494949494949494949494949494949494949
Contin-uousAmpereRating
Magnetic Trip Setting,Amperes➀
2 Poles➂ 3 Poles
Low High Catalogue Numbers
Magnetic Only, Front Adjustable Breakers
225225225225225
350 625 750 8751125
7001250150017502250
HKA2700TM
HKA21250TM
HKA21500TM
HKA21750TM
HKA22250TM
HKA3700TM
HKA31250TM
HKA31500TM
HKA31750TM
HKA32250TM
Ambient Compensating Breakers
70100125150175200225
350 500 625 750 87510001125
700100012501500175020002250
HKA2070TA
HKA2100TA
HKA2125TA
HKA2150TA
HKA2175TA
HKA2200TA
HKA2225TA
HKA3070TA
HKA3100TA
HKA3125TA
HKA3150TA
HKA3175TA
HKA3200TA
HKA3225TA
Special Calibration➃Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C, also price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See AD 29-160 for information regarding special conditions.
50°C Calibration➃Add suffix “V” to catalogue number for complete breaker, listed above, when ordering listed ampere ratings to be used in 50°C ambients. Same price as standard 40°C breakers.
Terminals➁Two terminals are required per pole. Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum conductors, use joint compound. To order optional copper only terminals, add suffix “C” to complete breaker catalogue number.
TypeCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagneticFrequency
Add 30% toList Price ofTrip Unit
NoneNoneNone
� Set on high side, adjustable to lower limit.� Terminals are shipped separately from breaker frame.� 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Not listed with UL/CSA � Optional terminal.� Ratings above 10,000 Amps not UL/CSA listed.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types JA, KA, MARK 75� Type HKA
Type KA Thermal Magnetic, Saf-T-Vue� and MARK 75� Type HKA Breakers
70-225 Amperes, 600 Volts AC, 250 Volts DC, 2 and 3 Poles, Interchangeable Trip
Contin-uousAmpereRatingat 40°C
Magnetic Trip SettingAmperes➀
Complete Breaker Shipped as Frame, Trip Unit and Terminals
Includes Pressure Type Aluminum Terminals➁ Frame Only Trip Unit Only
Standard Saf-T-Vue MARK 75 Standard Saf-T-Vue MARK 75
Standard MARK 75 orSaf-T-Vue
Low High Catalogue Numbers2 Poles, 600 Volts AC, 250 Volts DC➂
70 90100125150175200225
350 450 500 625 750 87510001125
700 900100012501500175020002250
KA2070KA2090KA2100KA2125KA2150KA2175KA2200KA2225
KA2070SKA2090SKA2100SKA2125SKA2150SKA2175SKA2200SKA2225S
HKA2070HKA2090HKA2100HKA2125HKA2150HKA2175HKA2200HKA2225
KA2225FKA2225FKA2225FKA2225FKA2225FKA2225FKA2225FKA2225F
KA2225FSKA2225FSKA2225FSKA2225FSKA2225FSKA2225FSKA2225FSKA2225FS
HKA2225FHKA2225FHKA2225FHKA2225FHKA2225FHKA2225FHKA2225FHKA2225F
HKA2070THKA2090THKA2100THKA2125THKA2150THKA2175THKA2200THKA2225T
Approx. Ship. Wt. 12 Lbs. Approx. Ship. Wt. 9-1⁄2 Lbs. Approx. Ship. Wt. 2 Lbs.
3 Poles, 600 Volts AC Only
70 90100125150175200225
350 450 500 625 750 87510001125
700 900100012501500175020002250
KA3070KA3090KA3100KA3125KA3150KA3175KA3200KA3225
KA3070SKA3090SKA3100SKA3125SKA3150SKA3175SKA3200SKA3225S
HKA3070HKA3090HKA3100HKA3125HKA3150HKA3175HKA3200HKA3225
KA325FKA325FKA325FKA325FKA325FKA325FKA325FKA325F
KA3225FSKA3225FSKA3225FSKA3225FSKA3225FSKA3225FSKA3225FSKA3225FS
HKA3225FHKA3225FHKA3225FHKA3225FHKA3225FHKA3225FHKA3225FHKA3225F
HKA3070THKA3090THKA3100THKA3125THKA3150THKA3175THKA3200THKA3225T
Approx. Ship. Wt. 14 Lbs. Approx. Ship. Wt. 11 Lbs. Approx. Ship. Wt. 2-1⁄2 Lbs.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
CSA and Underwriters Laboratories Inc. Interrupting Ratings
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Magnetic Only BreakersFor description, refer to AD 29-160. To order these breakers, select frame, trip unit and terminals.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Max. AmpsCatalogue Numbers
Wire Range, TypeNo. of Cables
Standard Al/Cu Pressure Terminals
225 TA225LA1 1 #6-350 MCM Cu, or1 #4-350 MCM Al
Optional Copper Pressure Terminals
225225➄
T225LAT225LBF
1 #6-350 MCM Cu1 #6-250 MCM Cu
Max. Volts Amperes
Standard Breakers
240 AC480 AC600 AC250 DC
30,000 Asym., 25,000 Sym.25,000 Asym., 22,000 Sym.25,000 Asym., 22,000 Sym.10,000
MARK 75 Breakers
240 AC480 AC600 AC250 DC
75,000 Asym., 65,000 Sym.40,000 Asym., 35,000 Sym.30,000 Asym., 25,000 Sym.20,000➅
8 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Type CA, CAH and HCA Circuit Breakers
2 and 3 Poles, 240 VAC; Non-Interchangeable Trip
Listed with CSA and Underwriters Laboratories Inc. except as noted.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Type CA: 100-225 Amperes, 10,000 AICType CAH: 100-225 Amperes, 22,000 AICType HCA: 100-225 Amperes, 42,000 AIC
Accessories
DescriptionCatalogueNumber
Handle Locks:Non-padlockable CA23NPL
Handle Locks:Padlockable CA23PL
CA23LOCK
Mounting Hardware:Base mounting hardware – 2-poleBase mounting hardware – 3-poleMounting BrACket – 2-poleMounting BrACket – 3-pole
CA2BHW
CA3BHW
CA2MB
CA3MB
Terminals:#3 to 300MCM TA225CA2
2 & 3 Pole Collar Kit 177C547G16
Type CA 3-Pole
Modifications
DescriptionCatalogueSuffix
Shunt TripAuxiliary SwitchSpecial Calibration (50°C)Freeze TestingMoisture-Fungus Treatment
S1 to S16A1 to A16VHF
Replacement AB DE-ION ® Circuit Breakers
Types CA, CAH and HCA 225 Amperes
Breaker Catalogue Numbers
Continuous AmpereRating at 40°C
Catalogue NumberBreaker Shipped with:Line and LoadTerminal Installed
Load TerminalsOnly Installed
Line TerminalsOnly Installed
No TerminalsInstalled
Type: CA 10,000 Ampere I.C. Thermal-Magnetic Breakers2-Pole, 240 VAC
100125150175200225225 MCS
CA2100CA2125CA2150CA2175CA2200CA2225 –
CA2100XCA2125XCA2150XCA2175XCA2200XCA2225X –
CA2100YCA2125YCA2150YCA2175YCA2200YCA2225Y –
CA2100WCA2125WCA2150WCA2175WCA2200WCA2225WCA2225WK
3-Pole, 240 VAC
100125150175200225225 MCS
CA3100CA3125CA3150CA3175CA3200CA3225 –
CA3100XCA3125XCA3150XCA3175XCA3200XCA3225X –
CA3100YCA3125YCA3150YCA3175YCA3200YCA3225Y –
CA3100WCA3125WCA3150WCA3175WCA3200WCA3225WCA3225WK
Type: CAH 22,000 Ampere I.C.Thermal-Magnetic Breakers2-Pole, 240 VAC
100125150175200225
CAH2100CAH2125CAH2150CAH2175CAH2200CAH2225
CAH2100XCAH2125XCAH2150XCAH2175XCAH2200XCAH2225X
CAH2100YCAH2125YCAH2150YCAH2175YCAH2200YCAH2225Y
CAH2100WCAH2125WCAH2150WCAH2175WCAH2200WCAH2225W
3-Pole, 240 VAC
100125150175200225
CAH3100CAH3125CAH3150CAH3175CAH3200CAH3225
CAH3100XCAH3125XCAH3150XCAH3175XCAH3200XCAH3225X
CAH3100YCAH3125YCAH3150YCAH3175YCAH3200YCAH3225Y
CAH3100WCAH3125WCAH3150WCAH3175WCAH3200WCAH3225W
Type: HCA 42,000 Ampere I.C. Thermal-Magnetic Breakers2-Pole, 240 VAC
100125150175200225
HCA2100HCA2125HCA2150HCA2175HCA2200HCA2225
HCA2100XHCA2125XHCA2150XHCA2175XHCA2200XHCA2225X
HCA2100YHCA2125YHCA2150YHCA2175YHCA2200YHCA2225Y
HCA2100WHCA2125WHCA2150WHCA2175WHCA2200WHCA2225W
3-Pole, 240 VAC
100125150175200225
HCA3100HCA3125HCA3150HCA3175HCA3200HCA3225
HCA3100XHCA3125XHCA3150XHCA3175XHCA3200XHCA3225X
HCA3100YHCA3125YHCA3150YHCA3175YHCA3200YHCA3225Y
HCA3100WHCA3125WHCA3150WHCA3175WHCA3200WHCA3225W
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 9
494949494949494949494949494949494949494949494949494949494949
Type LBB Breakers
125-400 Amperes, 600 Volts AC, 250 Volts DC, 2, 3 Poles, Fixed Trip Thermal Magnetic, and Saf-T-Vue� Breakers. Suitable for reverse feed application.
Contin-uousAmpereRatingat 40°C
Magnetic Trip Setting, Amperes➀
Complete Breaker
Includes Pressure Type Aluminum Terminals➁ Breaker Without Terminals
Standard Saf-T-Vue Standard Saf-T-VueLow High Catalogue Numbers
2 Poles, 600 Volts AC, 250 Volts DC➂
125150175200225250300350400
625 750 875100011251250150017502000
125015001750200022502500300035004000
LBB2125LBB2150LBB2175LBB2200LBB2225LBB2250LBB2300LBB2350LBB2400
LBB2125SLBB2150SLBB2175SLBB2200SLBB2225SLBB2250SLBB2300SLBB2350SLBB2400S
LBB2125WLBB2150WLBB2175WLBB2200WLBB2225WLBB2250WLBB2300WLBB2350WLBB2400W
LBB2125SWLBB2150SWLBB2175SWLBB2200SWLBB2225SWLBB2250SWLBB2300SWLBB2350SWLBB2400SW
Approx. Ship Wt. 13 Lbs. Approx. Ship Wt. 13 Lbs.
3 Poles, 600 Volts AC Only
125150175200225250300350400
625 750 875100011251250150017502000
125015001750200022502500300035004000
LBB3125LBB3150LBB3175LBB3200LBB3225LBB3250LBB3300LBB3350LBB3400
LBB3125SLBB3150SLBB3175SLBB3200SLBB3225SLBB3250SLBB3300SLBB3350SLBB3400S
LBB3125WLBB3150WLBB3175WLBB3200WLBB3225WLBB3250WLBB3300WLBB3350WLBB3400W
LBB3125SWLBB3150SWLBB3175SWLBB3200SWLBB3225SWLBB3250SWLBB3300SWLBB3350SWLBB3400SW
Approx. Ship Wt. 15 Lbs. Approx. Ship Wt. 15 Lbs.
Magnetic Only, Ambient Compensating Breakers➃
Contin-uousAmpereRating
Magnetic Trip Setting,Amperes➀
2-Pole Breakers➂ 3-Pole Breakers
Standard Saf-T-Vue Standard Saf-T-Vue
Low High Catalogue NumbersMagnetic Only Breakers, Front Adjustable – Without Terminals➄
400400400400400400400
350 625 750 875112515002000
700125015001750225030004000
LBB2700MWLBB21250MWLBB21500MWLBB21750MWLBB22250MWLBB23000MWLBB24000MW
LBB2700SMWLBB21250SMWLBB21500SMWLBB21750SMWLBB22250SMWLBB23000SMWLBB24000SMW
LBB3700MWLBB31250MWLBB31500MWLBB31750MWLBB32250MWLBB33000MWLBB34000MW
LBB3700SMWLBB31250SMWLBB31500SMWLBB31750SMWLBB32250SMWLBB33000SMWLBB34000SMW
Ambient Compensating Breakers – Includes Terminals
125150175200225250300350400
625 750 875100011251250150017502000
125015001750200022502500300035004000
LBB2125ALBB2150ALBB2175ALBB2200ALBB2225ALBB2250ALBB2300ALBB2350ALBB2400A
LBB2125SALBB2150SALBB2175SALBB2200SALBB2225SALBB2250SALBB2300SALBB2350SALBB2400SA
LBB3125ALBB3150ALBB3175ALBB3200ALBB3225ALBB3250ALBB3300ALBB3350ALBB3400A
LBB3125SALBB3150SALBB3175SALBB3200SALBB3225SALBB3250SALBB3300SALBB3350SALBB3400SA
Terminals➁Two required per pole. Select from page 10.
Magnetic Only and Ambient Compensating BreakersFor description, refer to AD 29-160. To order select catalogue number from table above.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
CSA and Underwriters Laboratories Inc. Interrupting Ratings
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Special Calibrations➃Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See AD 29-160 for information regarding special conditions. Maximum calibration for 400 Hz is 300 Amps.
50°C Calibration➃Add suffix “V” to catalogue number for complete breaker when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Max. Volts Amperes
240 AC480 AC600 AC250 DC
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.20,000➅
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagneticFrequency
Add 10% toList Price ofComplete Breaker
NoneNoneNone
� Set on high side, adjustable to lower limits.� Terminals are shipped separately from breaker.� 2-pole breakers or trips are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Not listed with CSA and Underwriters Laboratories Inc.� Select desired terminals from page 10, and order as separate item.� Ratings above 10,000 Amps not CSA and UL listed.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type LBB 400 Amperes
10 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Contin-uousAmpereRatingat 40°C
Magnetic Trip SettingAmperes➀
Complete Breaker
Includes Pressure Type Aluminum Terminals➁
Shipped as Frame, Trip Unit and
Terminals➁
Frame Only Trip Unit Only
Low HighStandard Saf-T-Vue MARK 75 Standard Saf-T-Vue MARK 75
StandardSaf-T-Vue,MARK 75
Catalogue Numbers2 Poles, 600 Volts AC, 250 Volts DC➂
70 90100125150175200225250300350400
350 450 500 625 750 875100011251250150017502000
700 9001000125015001750200022502500300035004000
LB2070LB2090LB2100LB2125LB2150LB2175LB2200LB2225LB2250LB2300LB2350LB2400
LB2070SLB2090SLB2100SLB2125SLB2150SLB2175SLB2200SLB2225SLB2250SLB2300SLB2350SLB2400S
HLB2070HLB2090HLB2100HLB2125HLB2150HLB2175HLB2200HLB2225HLB2250HLB2300HLB2350HLB2400
LB2400FLB2400FLB2400FLB2400FLB2400FLB2400FLB2400FLB2400FLB2400FLB2400FLB2400FLB2400F
LB2400FSLB2400FSLB2400FSLB2400FSLB2400FSLB2400FSLB2400FSLB2400FSLB2400FSLB2400FSLB2400FSLB2400FS
HLB2400FHLB2400FHLB2400FHLB2400FHLB2400FHLB2400FHLB2400FHLB2400FHLB2400FHLB2400FHLB2400FHLB2400F
HLB2070THLB2090THLB2100THLB2125THLB2150THLB2175THLB2200THLB2225THLB2250THLB2300THLB2350THLB2400T
Approx. Ship. Wt. 13 Lbs. Approx. Ship. Wt. 10 Lbs. Approx. Ship. Wt. 2 Lbs.
3 Poles, 600 Volts AC Only
70 90100125150175200225250300350400
350 450 500 625 750 875100011251250150017502000
700 9001000125015001750200022502500300035004000
LB3070LB3090LB3100LB3125LB3150LB3175LB3200LB3225LB3250LB3300LB3350LB3400
LB3070SLB3090SLB3100SLB3125SLB3150SLB3175SLB3200SLB3225SLB3250SLB3300SLB3350SLB3400S
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .HLB3125HLB3150HLB3175HLB3200HLB3225HLB3250HLB3300HLB3350HLB3400
LB3400FLB3400FLB3400FLB3400FLB3400FLB3400FLB3400FLB3400FLB3400FLB3400FLB3400FLB3400F
LB3400FSLB3400FSLB3400FSLB3400FSLB3400FSLB3400FSLB3400FSLB3400FSLB3400FSLB3400FSLB3400FSLB3400FS
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .HLB3400FHLB3400FHLB3400FHLB3400FHLB3400FHLB3400FHLB3400FHLB3400FHLB3400F
HLB3070THLB3090THLB3100THLB3125THLB3150THLB3175THLB3200THLB3225THLB3250THLB3300THLB3350THLB3400T
Approx. Ship Wt. 15 Lbs. Approx. Ship Wt. 12 Lbs. Approx. Ship Wt. 2-1⁄2 Lbs.
� Set on high side, adjustable to lower limits.� Terminals are shipped separately from breaker.� 2-pole breakers or trips are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Optional terminal.� Ratings above 10,000 Amps not CSA and UL listed.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
List Prices: See PAD (Price and Availability Digest)
Accessories and ModificationsDescription: Pages 39 - 49
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Volt Max. AmperesStandard Breakers
240 AC480 AC600 AC250 DC
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.20,000➄
MARK 75® Breakers
240 AC480 AC600 AC250 DC
75,000 Asym., 65,000 Sym.40,000 Asym., 35,000 Sym.30,000 Asym., 25,000 Sym.20,000➄
Terminals➁Two terminals are required per pole.
Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum cable, use joint compound. To order optional copper only terminals, add suffix “C” to complete breaker catalogue number.
Max.Amps.
TerminalCat. No.
Wire Range, TypeNo. of Cables
Standard Pressure Terminals
225
350400400
TA225LA1
TA350DATA400CDAT400DA2
1 #6-350 MCM Cu, or1 #4-350 MCM Al1 250-500 MCM Al/Cu2 3/0-250 MCM Al/Cu2 3/0-250 MCM Cu only
Optional Copper Pressure Terminals
225225➃350
T225LAT225LBFT350DA
1 #6-350 MCM Cu1 #6-250 MCM Cu1 250-500 MCM Cu
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type LB 400 Amperes, Mark 75� Type HLB400 Amperes
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 11
494949494949494949494949494949494949494949494949494949494949
List Prices: See PAD (Price and Availability Digest)
Type LB and Mark 75® Type HLB Breakers, (Continued)
70-400 Amperes, 600 Volts AC, 250 Volts DC, 2, 3 Poles, Interchangeable Trip
Special Breakers➀ Trip Units Only
ContinuousAmpereRating
Magnetic Trip Setting,Amperes➁
Trip Unit Only2 Poles➂ 3 Poles
Low High Catalogue NumbersMagnetic Only Breakers, Front Adjustable
400400400400400400400
350 625 750 875112515002000
700125015001750225030004000
HLB2700TMHLB21250TMHLB21500TMHLB21750TMHLB22250TMHLB23000TMHLB24000TM
HLB3700TMHLB31250TMHLB31500TMHLB31750TMHLB32250TMHLB33000TMHLB34000TM
Ambient Compensating Breakers
70 90100125150175200225250300350400
350 450 500 625 750 875100011251250150017502000
700 9001000125015001750200022502500300035004000
HLB2070TAHLB2090TAHLB2100TAHLB2125TAHLB2150TAHLB2175TAHLB2200TAHLB2225TAHLB2250TAHLB2300TAHLB2350TAHLB2400TA
HLB3070TAHLB3090TAHLB3100TAHLB3125TAHLB3150TAHLB3175TAHLB3200TAHLB3225TAHLB3250TAHLB3300TAHLB3350TAHLB3400TA
Magnetic Only and Ambient Compensating Breakers➀For description, refer to AD 29-160. To order, select trip unit from table at left, frame and terminals from page 10.
Special Calibrations➀Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See AD 29-160 for information regarding special conditions. Maximum calibration for 400 Hz is 300 Amps.
50°C Calibration➀Add suffix “V” to catalogue number for complete breaker or trip unit only, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagneticFrequency
Add 30% toList Price ofTrip Units
NoneNoneNone
� Not listed with CSA and Underwriters Laboratories Inc.� Set on high side, adjustable to lower limits.� 2-pole breakers or trips are supplied in 3-pole frames with current carrying parts omitted from centre pole.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type LB 400 Amperes, Mark 75� Type HLB400 Amperes
12 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Type DA 3 Pole
� 2-pole breakers are supplied in 3-pole frames.� Not CSA and UL listed.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type DA
Type DA Breakers
250-400 Amperes, 240 Volts AC, 250 Volts DC, 2 and 3 Poles, Fixed Trip Thermal Magnetic Breakers. Suitable for reverse feed application.
ContinuousAmpereRating at 40°C
Breakers With Line Terminals OnlyBreakers With Line and Load Terminals
Catalogue Numbers Catalogue Numbers
2-Pole➀ 3-Pole 2-Pole➀ 3-Pole
250300350400
DA2250YDA2300YDA2350YDA2400Y
DA3250YDA3300YDA3350YDA3400Y
DA2250DA2300DA2350DA2400
DA3250DA3300DA3350DA3400
Approx. Ship. Wt.13 Lbs.
Approx. Ship. Wt.15 Lbs.
Approx. Ship. Wt.13 Lbs.
Approx. Ship. Wt.15 Lbs.
Listed with CSA and Underwriters Laboratories Inc. except as noted.List Prices: See PAD (Price and Availability Digest)
Accessories and ModificationsDescription: Pages 39 - 49
Special Calibrations➁
Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See Application Data 29-160 for information regarding special conditions. Maximum 400 Hz calibrations: Type DA, 300 amps.
50°C Calibration➁
Add suffix “V” to catalogue number for complete breaker when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagneticFrequency
Add 10% ofList Price ofComplete Breaker
NoneNoneNone
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
TerminalsTerminals are CSA and Underwriters Laboratories Inc. listed for the wire type and size listed below. When used with aluminum conductors, use joint compound.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Max. Volts Amperes
240 AC250 DC
25,000 Asym., 22,000 Sym.10,000
Max.Amps.
CatalogueNumber
Wire Range, TypeNo. of Cables
Standard Pressure Terminals
350400
TA350DAT400DA2
1 250-500 MCM Al/Cu2 3/0-250 MCM Cu only
Optional Terminals (for Copper cable)
350 T350DA 1 250-500 MCM Cu
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 13
494949494949494949494949494949494949494949494949494949494949
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Terminals➁Two required per pole. Select from table on page 14.
Magnetic Only and Ambient Compensating BreakersFor description, refer to AD 29-160. To order, select catalogue number from table at left.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Max. Volts Amperes240 AC480 AC600 AC250 DC
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.20,000➆
Special Calibrations➃Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See AD 29-160 for information regarding special conditions. Maximum calibration for 400 Hz is 300 Amps.
50°C Calibration➃Add suffix “V” to catalogue number for complete breaker when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalMagneticFrequency
Add 10% to
List Price of
Complete Breaker
NoneNoneNone
� Set on high side, adjustable to lower limits.� Terminals shipped separately from breaker.� 2-pole breakers or trips are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Not listed with CSA and Underwriters Laboratories Inc.� Select desired terminals from page 14 and order as separate item.� Interrupting capacities shown do not apply to moulded case switches (MCS).� Ratings above 10,000 Amps not CSA and UL listed.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type LAB 400 Amperes
Type LAB Thermal Magnetic, Saf-T-Vue� Breakers
125-400 Amperes, 600 Volts AC, 250 Volts DC, 2, 3 Poles, Fixed Trip. Suitable for reverse feed application.
ContinuousAmpereRatingat 40°C
Magnetic Trip Setting,Amperes➀
Complete Breaker
Includes Pressure Type Aluminum Terminals➁ Breaker Without Terminals
Standard Saf-T-Vue Standard Saf-T-VueLow High Catalogue Numbers
2 Poles, 600 Volts AC, 250 Volts DC➂
125150175200225250300350400
625 750 875100011251250150017502000
125015001750200022502500300035004000
LAB2125LAB2150LAB2175LAB2200LAB2225LAB2250LAB2300LAB2350LAB2400
LAB2125SLAB2150SLAB2175SLAB2200SLAB2225SLAB2250SLAB2300SLAB2350SLAB2400S
LAB2125WLAB2150WLAB2175WLAB2200WLAB2225WLAB2250WLAB2300WLAB2350WLAB2400W
LAB2125SWLAB2150SWLAB2175SWLAB2200SWLAB2225SWLAB2250SWLAB2300SWLAB2350SWLAB2400SW
Approx. Ship. Wt. 22 Lbs. Approx. Ship. Wt. 22 Lbs.
3 Poles, 600 Volts AC Only
125150175200225250300350400
625 750 875100011251250150017502000
125015001750200022502500300035004000
LAB3125LAB3150LAB3175LAB3200LAB3225LAB3250LAB3300LAB3350LAB3400
LAB3125SLAB3150SLAB3175SLAB3200SLAB3225SLAB3250SLAB3300SLAB3350SLAB3400S
LAB3125WLAB3150WLAB3175WLAB3200WLAB3225WLAB3250WLAB3300WLAB3350WLAB3400W
LAB3125SWLAB3150SWLAB3175SWLAB3200SWLAB3225SWLAB3250SWLAB3300SWLAB3350SWLAB3400SW
Approx. Ship. Wt. 24-1⁄2 Lbs. Approx. Ship. Wt. 24-1⁄2 Lbs.
Special Breakers➃
ContinuousAmpereRating
Magnetic Trip Setting,Amperes➀
Breaker Catalogue Number
2 Poles➂ 3 PolesStandard Saf-T-Vue Standard Saf-T-Vue
Low High Catalogue NumbersMagnetic Only Breakers, Front Adjustable – Without Terminals➄
400400400400400400400
350 625 750 875112515002000
700125015001750225030004000
LAB2700MWLAB21250MWLAB21500MWLAB21750MWLAB22250MWLAB23000MWLAB24000MW
LAB2700SMWLAB21250SMWLAB21500SMWLAB21750SMWLAB22250SMWLAB23000SMWLAB24000SMW
LAB3700MWLAB31250MWLAB31500MWLAB31750MWLAB32250MWLAB33000MWLAB34000MW
LAB3700SMWLAB31250SMWLAB31500SMWLAB31750SMWLAB32250SMWLAB33000SMWLAB34000SMW
Ambient Compensating Breakers – Includes Terminals
125150175200225250300350400
625 750 875100011251250150017502000
125015001750200022502500300035004000
LAB2125ALAB2150ALAB2175ALAB2200ALAB2225ALAB2250ALAB2300ALAB2350ALAB2400A
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
LAB3125ALAB3150ALAB3175ALAB3200ALAB3225ALAB3250ALAB3300ALAB3350ALAB3400A
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
14 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
� Set on high side, adjustable to lower limits.� Terminals shipped separately from breaker.� Terminals, trip units and Accessories are not interchangeable between 400 and 600 ampere frames.� Not listed with CSA and Underwriters Laboratories Inc.� 2-pole breakers or trips are supplied in 3-pole frames with current carrying parts omitted from centre pole.� These ratings have interrupting capacities reduced to 25,000 Amps sym. at 240 volts, 20,000 Amps sym. at 480 volts, and 15,000 Amps sym. at 600 volts.� 400 amp frame only. Optional terminal. Interrupting capacities do not apply to moulded case switches (MCS).� Ratings above 10,000 Amps not CSA and UL listed.
Terminals➁➂Two terminals are required per pole. Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum cable, use joint compound. To order optional copper only terminals, add suffix “C” to complete breaker catalogue number.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type LA 400 Amperes, Mark 75� Type HLA 400 Amperes
For panelboard and switchboard applications where only line side or load side terminals are required, add suffix “X” to complete breaker catalogue number.
Type LA and MARK 75� Type HLA Breakers
70-400 Amperes, 600 Volts AC, 250 Volts DC, 2, 3 Poles, Interchangeable Trip
Contin-uousAmpereRatingat 40°C
Magnetic Trip SettingAmperes➀
Complete Breaker
Includes Pressure Type Aluminum Terminals➁
Shipped as Frame, Trip Unit and
Terminals
Frame OnlyTrip Unit Only➂
StandardSaf-T-Vue➃ MARK 75 Standard
Saf-T-Vue➃ MARK 75
Standard, MARK 75 or Saf-T-Vue
Low High Catalogue Numbers400 Ampere Frame Breakers2 Poles, 600 Volts AC, 250 Volts DC➄
70➅ 90➅100➅125150175200225250300350400
350 450 500 625 750 875100011251250150017502000
700 9001000125015001750200022502500300035004000
LA2070LA2090LA2100LA2125LA2150LA2175LA2200LA2225LA2250LA2300LA2350LA2400
LA2070SLA2090SLA2100SLA2125SLA2150SLA2175SLA2200SLA2225SLA2250SLA2300SLA2350SLA2400S
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .HLA2125HLA2150HLA2175HLA2200HLA2225HLA2250HLA2300HLA2350HLA2400
LA2400FLA2400FLA2400FLA2400FLA2400FLA2400FLA2400FLA2400FLA2400FLA2400FLA2400FLA2400F
LA2400FSLA2400FSLA2400FSLA2400FSLA2400FSLA2400FSLA2400FSLA2400FSLA2400FSLA2400FSLA2400FSLA2400FS
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .HLA2400FHLA2400FHLA2400FHLA2400FHLA2400FHLA2400FHLA2400FHLA2400FHLA2400F
HLA2070THLA2090THLA2100THLA2125THLA2150THLA2175THLA2200THLA2225THLA2250THLA2300THLA2350THLA2400T
Approx. Ship. Wt. 21-3⁄4 Lbs. Approx. Ship. Wt. 17-1⁄2 Lbs. Approx. Ship. Wt. 2-1⁄4 Lbs.
3 Poles, 600 Volts AC Only
70➅ 90➅100➅125150175200225250300350400
350 450 500 625 750 875100011251250150017502000
700 9001000125015001750200022502500300035004000
LA3070LA3090LA3100LA3125LA3150LA3175LA3200LA3225LA3250LA3300LA3350LA3400
LA3070SLA3090SLA3100SLA3125SLA3150SLA3175SLA3200SLA3225SLA3250SLA3300SLA3350SLA3400S
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .HLA3125HLA3150HLA3175HLA3200HLA3225HLA3250HLA3300HLA3350HLA3400
LA3400FLA3400FLA3400FLA3400FLA3400FLA3400FLA3400FLA3400FLA3400FLA3400FLA3400FLA3400F
LA3400FSLA3400FSLA3400FSLA3400FSLA3400FSLA3400FSLA3400FSLA3400FSLA3400FSLA3400FSLA3400FSLA3400FS
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .HLA3400FHLA3400FHLA3400FHLA3400FHLA3400FHLA3400FHLA3400FHLA3400FHLA3400F
HLA3070THLA3090THLA3100THLA3125THLA3150THLA3175THLA3200THLA3225THLA3250THLA3300THLA3350THLA3400T
Approx. Ship. Wt. 24-1⁄2 Lbs. Approx. Ship. Wt. 19 Lbs. Approx. Ship. Wt. 3 Lbs.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Accessories and ModificationsDescriptions: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings➈
Volts Max. AmperesStandard Breakers
240 AC480 AC600 AC250 DC
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.20,000➉
MARK 75� Breakers
240 AC480 AC600 AC250 DC
75,000 Asym., 65,000 Sym.40,000 Asym., 35,000 Sym.30,000 Asym., 25,000 Sym.20,000➉
Max.Amps
TerminalCatalogueNumber
Wire Range, Type,No. of Cables
Standard Al/Cu Pressure Terminals
225➆
400➆
TA225LA1
TA400LA1
1 #6-350 MCM Cu, or1 #4-350 MCM Al1 #4-250 MCM Al/Cu, plus1 3/0-600 MCM Al/Cu
Optional Copper Pressure Terminals
225➆225➆➇400➆
T225LAT225LBFT401LA
1 #6-350 MCM Cu1 #6-250 MCM Cu1 #4-250 MCM Cu, plus1 3/0-600 MCM Cu
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 15
494949494949494949494949494949494949494949494949494949494949
Special Breakers➀ Trip Units Only
Contin-uousAmpereRating
Magnetic Trip Setting,Amperes➁ 2 Poles➂ 3 PolesLow High Catalogue Numbers
Magnetic Only Breakers, Front Adjustable400 Ampere Frame Breakers➃
400400400400400400400
350 625 750 875112515002000
700125015001750225030004000
HLA2700TMHLA21250TMHLA21500TMHLA21750TMHLA22250TMHLA23000TMHLA24000TM
HLA3700TMHLA31250TMHLA31500TMHLA31750TMHLA32250TMHLA33000TMHLA34000TM
Ambient Compensating Breakers400 Ampere Frame Breakers Only➃
70➄ 90➄100➄125150175200225250300350400
350 450 500 625 750 875100011251250150017502000
700 9001000125015001750200022502500300035004000
HLA2070TAHLA2090TAHLA2100TAHLA2125TAHLA2150TAHLA2175TAHLA2200TAHLA2225TAHLA2250TAHLA2300TAHLA2350TAHLA2400TA
HLA3070TAHLA3090TAHLA3100TAHLA3125TAHLA3150TAHLA3175TAHLA3200TAHLA3225TAHLA3250TAHLA3300TAHLA3350TAHLA3400TA
Magnetic Only and Ambient Compensating Breakers➀
For description, refer to AD 29-160. To order, select trip unit from table at left, frame and terminals from page 14.
Special Calibrations➀Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also Price additions apply to specific calibrations for frequencies other than 0-60 Hertz AC circuits. See AD 29-160 for information regarding special conditions. Maximum 400/415 Hz calibration: 400 amp frame, 300 Amps.
50°C Calibration➀Add suffix “V” to catalogue number for complete breaker or trip unit only, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
List Prices: See PAD (Price and Availability Digest)
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
ThermalAmbientFrequency
Add 30% toList Price ofTrip Unit
NoneNoneNone
� Not listed with CSA and Underwriters Laboratories Inc.� Set on high side, adjustable to lower limits.� 2-pole breakers or trips are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Terminals, trip units and accessories are not interchangeable between 400 and 600 amp frames.� These ratings have lower interrupting capacities. See note 6, page 14.
Type LA Breakers
70-400 Amperes, 600 Volts AC, 250 Volts DC, 2, 3 Poles, Interchangeable Trip
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type LA 400 Amperes, MARK 75� Type HLA 400 Amperes
16 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Replacement AB DE-ION ® Circuit Breakers
Type LA 600 Amperes, MARK 75� Type HLA 600 Amperes
Listed with Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Terminals➁➂
Two terminals are required per pole. Terminals are CSA and UL listed for wire type and range listed below. When used with aluminum cable, use joint compound. To order optional copper only terminals, add suffix “C” to complete breaker catalogue number.
Magnetic Only and AmbientCompensating Breakers➄
For description, refer to AD 29-160. To order, select frame, trip unit and terminals from tables this page.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings➅
Volts Max. AmperesStandard Breakers
240 AC480 AC600 AC250 DC
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.20,000➆
MARK 75® Breakers
240 AC480 AC600 AC250 DC
75,000 Asym., 65,000 Sym.40,000 Asym., 35,000 Sym.30,000 Asym., 25,000 Sym.20,000➆
Max.Amps
TerminalCatalogueNumber
Wire Range, TypeNo. of Cables
Standard Al/Cu Pressure Terminals
600➇ TA600LA 2 250-500 MCM Al/Cu
Optional Copper Pressure Terminals
600➇ T600LA 2 250-500 MCM Cu
For Panelboard and Switchboards applications where only line side or load side terminals are required, add suffix “X” to complete breaker catalogue number.
Type LA and MARK 75� Type HLA 600 Amp Breakers
250-600 Amperes, 600 Volts AC, 250 Volts DC, 2, 3 Poles, Interchangeable Trip ThermalMagnetic, Saf-T-Vue� and MARK 75� Breakers
Contin-uousAmpereRatingat 40°C
Magnetic Trip Setting Amperes ➀
Complete Breaker Shipped as Frame, Trip Unit and Terminals➁
Includes Pressure Type Aluminum Terminals➁ Frame Only
Trip UnitOnly
Catalogue Numbers
Low High Standard Saf-T-Vue MARK 75 Standard Saf-T-Vue MARK 75
Standard,Saf-T-Vue,MARK 75
600 Ampere Frame Breakers➂
2 Poles, 600 Volts AC, 250 Volts DC➃
250300350400500600
125015001750200025003000
250030003500400050006000
2603D50G012603D50G022603D50G032603D50G04LA2500LA2600
2603D50G132603D50G142603D50G152603D50G16LA2500SLA2600S
1256C10G021256C10G031256C10G041256C10G05HLA2500HLA2600
LA2600FLA2600FLA2600FLA2600FLA2600FLA2600F
LA2600FSLA2600FSLA2600FSLA2600FSLA2600FSLA2600FS
HLA2600FHLA2600FHLA2600FHLA2600FHLA2600FHLA2600F
2603D46G072603D46G082603D46G092603D46G10HLA2500THLA2600T
3 Poles, 600 Volts AC Only
250300350400500600
125015001750200025003000
250030003500400050006000
2603D50G072603D50G082603D50G092603D50G10LA3500LA3600
2603D50G192603D50G202603D50G212603D50G22LA3500SLA3600S
1256C10G121256C10G131256C10G141256C10G15HLA3500HLA3600
LA3600FLA3600FLA3600FLA3600FLA3600FLA3600F
LA3600FSLA3600FSLA3600FSLA3600FSLA3600FSLA3600FS
HLA3600FHLA3600FHLA3600FHLA3600FHLA3600FHLA3600F
2603D46G262603D46G272603D46G282603D46G29HLA3500THLA3600T
Special Calibrations➄
Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also price additions apply to specific calibrations for frequencies other than 0-60 Hz AC circuits. See Application Data 29-160 for information regarding special conditions. Maximum 400 Hz calibration: 600 amp frame, 450 amps.
50°C Calibration➄
Add suffix “V” to catalogue number for complete breaker or trip unit only, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24 IdenticalUnits
25 or MoreIdentical Units
ThermalAmbientFrequency
Add 20% to
List Price or
Trip Unit
NoneNoneNone
Special Breakers➄ Trip Units OnlyContin-uousAmpereRating
MagneticTrip Setting,Amperes➀ Catalogue/style NumberLow High 2-Poles➃ 3-Poles
600 Ampere Frame Breakers➂
Magnetic Only Breakers, Front Adjustable
600600600600600
11251500200025003000
22503000400050006000
2603D47G072603D47G082603D47G10HLA25000TMHLA26000TM
2603D47G262603D47G272603D47G29HLA35000TMHLA36000TM
Ambient Compensating Breakers
250300350400500600
125015001750200025003000
250030003500400050006000
5683D88G075683D88G085683D88G095683D88G10HLA2500TAHLA2600TA
5683D88G265683D88G275683D88G285683D88G29HLA3500TAHLA3600TA
� Set on high side, adjustable to lower limits.� Terminals shipped separately from breakers.� Terminals, trip units and accessories are not interchangeable between 400 and 600 ampere frames.� Two-pole breakers or trips are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Not listed with CSA and Underwriters Laboratories Inc.� Interrupting capacities shown do not apply to moulded case switches.� Ratings above 10,000 amps not CSA and UL listed. For 600 amp frame breakers only.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 17
494949494949494949494949494949494949494949494949494949494949
Replacement AB DE-ION ® Circuit Breakers
Type LAY, 240 Volt, 3-Pole 250-600 Ampere
50°C Calibration➃
Add suffix "V" to catalogue number for complete breaker or trip unit only, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
Type LAY breakers are not defined by Federal Specification W-C-375b.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Volts Max. Amperes240 AC 115,000 Asym., 100,000 Sym.
Type LAY 600 Amp Frame Breakers
250-600 Amperes, 240 Volts AC, 3 Poles, Interchangeable Trip Thermal Magnetic
ContinuousAmpereRatingat 40°C
Magnetic TripSetting Amperes➀
Complete Breaker Shipped as Frame, Trip Unit and Terminals➂
Includes Pressure Type Aluminum Terminals➁ Frame Only
Trip UnitOnly
Low High Catalogue Number600 Ampere Frame Breakers➃ 3 Poles, 240 Volts AC Only
250300350400500600
125015001750200025003000
250030003500400050006000
LAY3250LAY3300LAY3350LAY3400LAY3500LAY3600
LAY3600FLAY3600FLAY3600FLAY3600FLAY3600FLAY3600F
2603D46G262603D46G272603D46G282603D46G29HLA3500THLA3600T
Special Calibrations➃
Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. Also price additions apply to specific calibrations for frequencies other than 0-60 Hz AC circuits. See application data 29-160 for information regarding special conditions. Maximum 400 Hz calibration: 600 Amp frame, 450 Amps.
Type ofCalibration
1-24 identicalUnits
25 or MoreIdentical Units
ThermalAmbientFrequency
Add 20% toList Price ofTrip Unit
NoneNoneNone
Terminals➁
Two terminals are required per pole. Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum cable, use joint compound.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Max.Amps
TerminalCat. Number
Wire Range TypeNo. of Cables
Standard Al/Cu Pressure Terminals
500➂600➂600➂
TA602LD➄TA603LA➄TA600LA➄
(2) 250-350 MCM Al/Cu(2) 400-500 MCM Al/Cu(2) 250-500 MCM Al/Cu
Optional Copper Pressure Terminals
600➃ T600LA (2) 250-500 MCM Cu
� Set on high side, adjustable to lower limits.� Terminals shipped separately from breakers.� For 600 Amp frame breakers only.� Not listed with CSA and Underwriters Laboratories Inc.� Type Al9Cu aluminum terminal.
Shaded gray areas denotes obsolete or discontinued products and services
18 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type MA 800 Amperes, Type MAY 240 Volt AC, 3-Pole MARK 75� Type HMA 800 Amperes
Type MA Breakers
125-800 Amperes, 600 Volts AC, 250 Volts DC➀ 2, 3 Poles, Interchangeable Trip
Contin-uousAmpereRatingat 40°C
Magnetic Trip SettingAmperes➁
Complete BreakerIncludes Pressure Type Copper Terminals➂
Shipped as Frame, Trip Unit and Terminals➂
Frame Only Trip Unit Only
Standard Saf-T-Vue MARK 75 Standard Saf-T-Vue MARK 75
StandardSaf-T-Vue,MARK 75
Low High Catalogue Numbers2 Poles, 600 Volts AC, 250 Volts DC➀➃
125150175200225250300350400500600700➄800➄
625 750 8751000112512501500175020002500300030003000
1250150017502000225025003000350040005000600060006000
MA2125MA2150MA2175MA2200MA2225MA2250MA2300MA2350MA2400MA2500MA2600MA2700MA2800
MA2125SMA2150SMA2175SMA2200SMA2225SMA2250SMA2300SMA2350SMA2400SMA2500SMA2600SMA2700SMA2800S
HMA2125HMA2150HMA2175HMA2200HMA2225HMA2250HMA2300HMA2350HMA2400HMA2500HMA2600HMA2700HMA2800
MA2800FMA2800FMA2800FMA2800FMA2800FMA2800FMA2800FMA2800FMA2800FMA2800FMA2800FMA2800FMA2800F
MA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FSMA2800FS
HMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800FHMA2800F
HMA2125THMA2150THMA2175THMA2200THMA2225THMA2250THMA2300THMA2350THMA2400THMA2500THMA2600THMA2700THMA2800T
Approx. Ship. Wt. 37 Lbs. Approx. Ship. Wt. 24 Lbs. Approx. Ship. Wt. 3-1⁄2 Lbs.
3 Poles, 600 Volts AC Only
125150175200225250300350400500600700➄800➄
625 750 8751000112512501500175020002500300030003000
1250150017502000225025003000350040005000600060006000
MA3125MA3150MA3175MA3200MA3225MA3250MA3300MA3350MA3400MA3500MA3600MA3700MA3800
MA3125SMA3150SMA3175SMA3200SMA3225SMA3250SMA3300SMA3350SMA3400SMA3500SMA3600SMA3700SMA3800S
HMA3125HMA3150HMA3175HMA3200HMA3225HMA3250HMA3300HMA3350HMA3400HMA3500HMA3600HMA3700HMA3800
MA3800FMA3800FMA3800FMA3800FMA3800FMA3800FMA3800FMA3800FMA3800FMA3800FMA3800FMA3800FMA3800F
MA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FSMA3800FS
HMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800FHMA3800F
HMA3125THMA3150THMA3175THMA3200THMA3225THMA3250THMA3300THMA3350THMA3400THMA3500THMA3600THMA3700THMA3800T
Approx. Ship. Wt. 44 Lbs. Approx. Ship. Wt. 28 Lbs. Approx. Ship. Wt. 4 Lbs.
Magnetic Only and Ambient Compensating BreakersFor description, refer to AD 29-160. To order a complete breaker, select trip unit plus frame and terminals.
Special Calibrations➅Special calibration price additions apply to ampere ratings not listed as standard, ambients other than 40°C or 50°C, or frequencies other than 60 Hertz AC (50 Hertz AC minimum – 60 Hertz AC maximum) See AD 29-160 for additional information regarding special conditions.
50°C Calibration➅Add suffix “V” to catalogue number for complete breaker or trip unit only, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24 IdenticalUnits
25 or MoreIdentical Units
ThermalAmbientFrequency
Add 20% ofTrip UnitList Price
NoneNoneNone
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Terminals➂Two terminals are required per pole. Terminals are CSA and UL listed for wire type and range listed below. When used with aluminum conductors, use joint compound.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Max. Volts AmperesStandard Breakers
240 AC480 AC600 AC250 DC➀
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.20,000➆
MARK 75� Breakers
240 AC480 AC600 AC250 DC➀
75,000 Asym., 65,000 Sym.40,000 Asym., 35,000 Sym.30,000 Asym., 25,000 Sym.20,000➆
Max.Amps
TerminalCat. No.
Wire Range, TypeNo. of Cables
Standard Al/Cu Pressure Terminals
600800800➆
TA700MA1TA800MA2TA801MA
2 #1-500 MCM Al/Cu3 3⁄0-400 MCM Al/Cu2 500-750 MCM Al/Cu
Optional Copper Pressure Terminals
350600800
T350MAT600MA1T800MA1
1 #1-600 MCM Cu2 2⁄0-500 MCM Cu3 3⁄0-300 MCM Cu
� Above 600 Amps, DC rating applies to magnetic only breakers.� Set on high side, adjustable to lower limits.� Terminals are shipped separately from breaker.� 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.� 60 Hertz AC only.� Not listed with CSA and Underwriters Laboratories Inc.� Ratings above 10,000 Amps not CSA and UL listed.
Magnetic Only Breakers, Front Adj.➅
Contin-uousAmpereRating
Magnetic Trip Range➁
Trip Unit Only2 Poles➃ 3 Poles
Low High Catalogue Number800800800800800800
62510001500200030004000
125020003000400060008000
HMA21250TMHMA22000TMHMA23000TMHMA24000TMHMA26000TMHMA28000TM
HMA31250TMHMA32000TMHMA33000TMHMA34000TMHMA36000TMHMA38000TM
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Ambient Compensating Breakers➅
Contin-uousAmpereRating
Magnetic Trip Range➁
Trip Unit Only2 Poles 3 Poles
Low High Catalogue Number125150175200225250300350400500600700800
625 750 8751000112512501500175020002500300030003000
1250150017502000225025003000350040005000600060006000
HMA2125TAHMA2150TAHMA2175TAHMA2200TAHMA2225TAHMA2250TAHMA2300TAHMA2350TAHMA2400TAHMA2500TAHMA2600TAHMA2700TAHMA2800TA
HMA3125TAHMA3150TAHMA3175TAHMA3200TAHMA3225TAHMA3250TAHMA3300TAHMA3350TAHMA3400TAHMA3500TAHMA3600TAHMA3700TAHMA3800TA
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 19
494949494949494949494949494949494949494949494949494949494949
Type MAY Breakers
600-800 Amperes, 240 Volts AC. 3 Poles, Interchangeable Trip
ContinuousAmpereRatingat 40°C
Magnetic TripSetting,Amperes➀
Complete Breaker Shipped as Frame, Trip Unit and Terminals➁
Includes Pressure TypeAluminum Terminals➁ Frame Only Trip Unit Only
Low High Catalogue Numbers3 Poles, 240 Volts AC Only
600700➂800➂
300030003000
600060006000
MAY3600MAY3700MAY3800
MAY3800FMAY3800FMAY3800F
HMA3600THMA3700THMA3800T
Terminals➁
Two terminals are required per pole. Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum cable, use joint compound.
Max.Amps
TerminalCat. No.
Wire Range, TypeNo. of Cables
Standard Al/Cu Pressure Terminals
600800800
TA700MA1➃TA800MA2➃TA801MA➃
2 #1-500 MCM Al/Cu3 3/0-400 MCM Al/Cu2 500-750 MCM Al/Cu
Optional Copper Pressure Terminals
350600800
T350MAT600MA1T800MA1
1 #1-600 MCM Cu2 2/0-500 MCM Cu3 3/0-300 MCM Cu
Listed with CSA and Underwriters Laboratories Inc. except as noted.
Type MAY breakers are not defined by Federal Specification W-C-375b.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
CSA and Underwriters Laboratories Inc. listed Interrupting Ratings
Volts Max. Amperes
240 AC 115,000 Asym., 100,000 Sym.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types MA, MAY, MARK 75� HMA (cont’d)
� Set on high side, adjustable to lower limit.� Terminals shipped separate from breaker.� 60 Hertz AC only.� Type AI9Cu aluminum terminal.
20 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Special Calibrations➆
Special calibration price additions apply to ampere ratings not listed as standard, ambients other than 40°C or 50°C or frequencies other than 60 Hertz AC (50 Hertz AC minimum – 60 Hertz AC maximum for ratings of 700 Amps and above). See AD 29-160 for additional information regarding special conditions. Maximum 400 Hz calibration for type MA is 475 Amps
50°C Calibration➆
Add suffix “V” to catalogue number for complete breaker or trip unit only, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Type ofCalibration
1-24 Identical Units 25 orMoreIdent.Units
TypeMA, HMA
TypeNB, HNB
ThermalAmbientFrequency
Add 20%
of
Trip Unit
List Price
Add 15%
of
Trip Unit
List Price
NoneNoneNone
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Terminals➅
Two terminals are required per pole. Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum conductors, use joint compound. To order optional copper terminals, add suffix “C” to complete breaker catalogue number.
CSA and Underwriters Laboratories Inc. listed Interrupting Ratings:
Max. Volts AmperesStandard Breakers
240 AC480 AC600 AC250 DC➁
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.20,000➇
MARK 75� Breakers
240 AC480 AC600 AC250 DC➁
75,000 Asym., 65,000 Sym.40,000 Asym., 35,000 Sym.30,000 Asym., 25,000 Sym.20,000➇
Max.AmpereRatings
TerminalCatalogueNumber
Wire Range, Type,No. of Cables
Standard Al/Cu Pressure Terminals
10001200
TA1000NB1TA1200NB1
3 3/0-400 MCM Al/Cu4 4/0-500 MCM Al/Cu
Optional Copper or Al/Cu Pressure Terminals
100012001200
T1000NB1T1200NB1TA1201NB1
3 3/0-500 MCM Cu4 3/0-400 MCM Cu3 500-750 MCM Al/Cu
� Higher frequency calibration not available. Minimum of 50 cycle calibration available on special order.� 250-volt DC rating applied only to magnetic only type breakers.� Set on high side, adjustable to lower limits.� Terminals shipped separately from breaker.� 2-pole breakers supplied in 3-pole frames with current carrying parts omitted from centre pole. � Frames, terminals, studs, mounting hardware, dimensions and shipping weights are same as standard thermal magnetic breakers.� Not listed with CSA and Underwriters Laboratories Inc. Ratings above 10,000 Amps not CSA and UL listed.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type NB 1200 Amperes, Type NBY, 240 Volt 3-Pole, MARK 75®, Type HNB 1200 Amperes
Magnetic Only Breakers➆For description, refer to AD 29-160. To order a complete breaker, select trip unit, plus frame and terminals.
Magnetic Only Breakers, FrontAdjustable➅➆
Continu-ousAmpereRating
MagneticTrip Range➂
Trip Unit Only2 Poles➄ 3 Poles
Low High Catalogue Numbers1200120012001200
3000400050006000
6000 80001000012000
HNB26000TMHNB28000TMHNB210000TMHNB212000TM
HNB36000TMHNB38000TMHNB310000TMHNB312000TM
Type NB Breakers
700-1200 Amperes, 600 Volts, 60 Hertz AC➀ , 250 Volts DC➁ , 2, 3 Poles, Interchangeable Trip
Contin-uousAmpereRatingat 40°C
Magnetic Trip Setting,Amperes➂
Complete Breaker Shipped as Frame, Trip Unit and Terminals➃
Includes Pressure TypeCopper Terminals➃ Frame Only
Trip UnitOnly
Low HighStandard Saf-T-Vue MARK 75 Standard Saf-T-Vue MARK 75
StandardSaf-T-Vue,MARK 75
Catalogue Numbers2 Poles, 600 Volts AC, 250 Volts DC➁➄
700 800 90010001200
30003000400040004000
60006000800080008000
NB2700NB2800NB2900NB21000NB21200
NB2700SNB2800SNB2900SNB21000SNB21200S
HNB2700HNB2800HNB2900HNB21000HNB21200
NB21200FNB21200FNB21200FNB21200FNB21200F
NB21200FSNB21200FSNB21200FSNB21200FSNB21200FS
HNB21200FHNB21200FHNB21200FHNB21200FHNB21200F
HNB2700THNB2800THNB2900THNB21000THNB21200T
Approx. Ship. Wt. 43 Lbs. Approx. Ship. Wt. 29 Lbs. Approx. Ship.Wt. 31⁄2 Lbs.
3 Poles, 600 Volts AC Only
700 800 90010001200
30003000400040004000
60006000800080008000
NB3700NB3800NB3900NB31000NB31200
NB3700SNB3800SNB3900SNB31000SNB31200S
HNB3700HNB3800HNB3900HNB31000HNB31200
NB31200FNB31200FNB31200FNB31200FNB31200F
NB31200FSNB31200FSNB31200FSNB31200FSNB31200FS
HNB31200FHNB31200FHNB31200FHNB31200FHNB31200F
HNB3700THNB3800THNB3900THNB31000THNB31200T
Approx. Ship. Wt. 51 Lbs. Approx. Ship. Wt. 32 Lbs. Approx. Ship.Wt. 4 Lbs.
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 21
494949494949494949494949494949494949494949494949494949494949
Special Calibrations➃
Special calibration price additions apply to ampere ratings not listed as standard, ambients other than 40°C or 50°C, or frequencies other than 60 Hertz AC (50 Hertz AC minimum – 60 Hertz AC maximum) See AD 29-160 for additional information regarding special conditions.
50°C Calibration➃
Add suffix “V” to catalogue number for complete breaker or trip unit only, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24 IdenticalUnits
25 or MoreIdentical Units
ThermalAmbientFrequency
Add 15% ofTrip UnitList Price
NoneNoneNone
Type NBY Breakers
700-1200 Amperes, 240 Volts, 60 Hertz AC➀ , 3 Poles, Interchangeable Trip
ContinuousAmpereRatingat 40°C
Magnetic TripSettingAmperes➁
Complete Breaker Shipped as Frame, Trip Unit and Terminals➂
Includes Pressure TypeAluminum Terminals➂ Frame Only Trip Unit Only
Low High Catalogue Numbers3 Poles, 600 Volts AC Only
700 800 90010001200
30003000400040004000
60006000800080008000
NBY3700NBY3800NBY3900NBY31000NBY31200
NBY31200FNBY31200FNBY31200FNBY31200FNBY31200F
HNB3700THNB3800THNB3900THNB31000THNB31200T
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Listed with CSA and Underwriters Laboratories Inc. except as noted.
Type NBY breakers are not defined by Federal Specification W-C-375b.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
CSA and Underwriters Laboratories Inc. listed Interrupting Ratings
Volts Max. Amperes240 AC 115,000 Asym., 100,000 Sym.
Terminals➂
Two terminals are required per pole. Terminals are CSA and Underwriters Laboratories Inc. listed for wire type and range listed below. When used with aluminum conductors, use joint compound.
Max.AmpereRatings
TerminalCatalogueNumber
Wire Range, Type,No. of Cables
Standard Al/Cu Pressure Terminals
100012001200
TA1000NB1➄TA1200NB1➄TA1201NB1➄
3 3/0-400 MCM Al/Cu4 4/0-500 MCM Al/Cu3 500-750 MCM Al/Cu
Alternate Copper Pressure Terminals
10001200
T1000NB1T1200NB1
3 3/0-500 MCM Cu4 3/0-400 MCM Cu
� Higher frequency calibration not available. Minimum of 50 cycle calibration available on special order.� Set on high side, adjustable to lower limits.� Terminals shipped separately from breaker.� Not listed with CSA and Underwriters Laboratories Inc.� Type Al9Cu aluminum terminal.� Type Al7Cu aluminum terminal.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types NB, NBY, MARK 75® Type HNB (cont’d)
22 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Special Breakers➆ (See page 23 also)Magnetic Only, Front Adjustable➇Trip Unit Only
Contin-uousAmpereRating
MagneticTrip Range,Amperes➃ 2 Poles➅ 3 Poles
Low High Catalogue NumberFor Rear Connected Type PB Breakers
2000200020002000200020002500
1500200025003000350040004000
5000 6000 7000 8000100001200012000
PB25000TMPB26000TMPB27000TMPB28000TMPB210000TMPB212000TM373D488G08
PB35000TMPB36000TMPB37000TMPB38000TMPB310000TMPB312000TM373D488G09
For Front Connected Type PBF Breakers
200020002000200020002000
150020002500300035004000
5000 6000 7000 80001000012000
PBF25000TMPBF26000TMPBF27000TMPBF28000TMPBF210000TMPBF212000TM
PBF35000TMPBF36000TMPBF37000TMPBF38000TMPBF310000TMPBF312000TM
Type PB Breakers
600-2500 Amperes, 600 Volts, 60 Cycle AC➀ , 250 Volts DC➁ , 2, 3 Poles, Interchangeable Trip
ContinuousAmpereRatingat 40°C
Magnetic Trip Setting,Amperes➂➃
Complete Breaker Shipped as Frame, Trip Unit and ConnectorsIncludes Bus BarConnectors➄ Frame Only Trip Unit Only
Low High Catalogue Numbers2 Poles, 600 Volts AC Only➅
600 700 800 900100012001400160018002000
1500150015001500150020002500300030003000
5000500050005000500060007000800080008000
PB2600PB2700PB2800PB2900PB21000PB21200PB21400PB21600PB21800PB22000
PB22500FPB22500FPB22500FPB22500FPB22500FPB22500FPB22500FPB22500FPB22500FPB22500F
PB2600TPB2700TPB2800TPB2900TPB21000TPB21200TPB21400TPB21600TPB21800TPB22000T
Approx. Ship. Wt. 132 Lbs. 78 Lbs. 18 Lbs.
2500 3000 8000 PB22500 PB22500F PB22500T
Approx. Ship. Wt. 144 Lbs. 98 Lbs. 18 Lbs.
3 Poles, 600 Volts AC Only
600 700 800 900100012001400160018002000
1500150015001500150020002500300030003000
5000500050005000500060007000800080008000
PB3600PB3700PB3800PB3900PB31000PB31200PB31400PB31600PB31800PB32000
PB32500FPB32500FPB32500FPB32500FPB32500FPB32500FPB32500FPB32500FPB32500FPB32500F
PB3600TPB3700TPB3800TPB3900TPB31000TPB31200TPB31400TPB31600TPB31800TPB32000T
Approx. Ship. Wt. 155 Lbs. 108 Lbs. 23 Lbs.
2500 3000 8000 PB32500 PB32500F PB32500T
Approx. Ship. Wt. 173 Lbs. 108 Lbs. 23 Lbs.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Bus Bar Connections➄“T” Connector(For Cu/AI Bus)Two required per pole. For rear bus connection ofbreakers thru 2000 Amps.accepts up to four bus bolts. May be rotated 90°.
Catalogue Number BA2000PB
“C” Connector(For Cu/AI Bus)Two required per pole. For rear bus connection of 2500 amp breakers.
Catalogue Number BA2500PB
Cable ConnectorFits “T” Connector and 2000 amp front connected breakers.accepts four 250-600 MCM copper cables.
Style Number 505C706G04
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Max. Volts Amperes240 AC480 AC600 AC250 DC➆
150,000 Asym., 125,000 Sym.115,000 Asym., 100,000 Sym.115,000 Asym., 100,000 Sym. 75,000 Amperes➈
Magnetic Only Breakers➆
For description, refer to AD 29-160. To order a complete breaker, select trip unit, plus frame and connectors.
Accessories and ModificationsDescription: Pages 39 - 49
List Prices: See PAD (Price and Availability Digest)
Special Calibration➆See Page 23.
Rear Connected PB Breaker
� Higher frequency calibration not available. Minimum of 50 Hertz calibration available on special order.� Available only on magnetic only breakers.� Higher magnetic trip settings are available as special calibration. Refer to magnetic only breakers for specific trip ranges.� Set on high side, adjustable to lower limits.� Shipped separately from breaker.� 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.� Not listed with CSA and Underwriters Laboratories Inc. Frames, connectors, dimensions and shipping weights are same as thermal magnetic breakers. Based on NEMA test procedure.
Shaded gray areas denotes obsolete
Replacement AB DE-ION ® Circuit Breakers
Type PB 2500 Amperes
or discontinued products and services
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 23
494949494949494949494949494949494949494949494949494949494949
Type PB Breakers, (continued)Type PBF Front Connected Breakers
ContinuousAmpereRatingat 40°C
Magnetic Trip Setting,Amperes (Set on High Side, Adjustable to Lower Limits)
Complete Breaker Shipped As:
Includes Bus BarConnectors➀
Frame OnlyIncludes Bus BarConnectors➀ Trip Unit Only
Low High Catalogue Numbers2-Pole, 600 Volts AC➁
600 700 800 900100012001400160018002000
1500150015001500150020002500300030003000
5000500050005000500060007000800080008000
PBF2600PBF2700PBF2800PBF2900PBF21000PBF21200PBF21400PBF21600PBF21800PBF22000
PBF22000FPBF22000FPBF22000FPBF22000FPBF22000FPBF22000FPBF22000FPBF22000FPBF22000FPBF22000F
PBF2600TPBF2700TPBF2800TPBF2900TPBF21000TPBF21200TPBF21400TPBF21600TPBF21800TPBF22000T
3-Pole, 600 Volts AC
600 700 800 900100012001400160018002000
1500150015001500150020002500300030003000
5000500050005000500060007000800080008000
PBF3600PBF3700PBF3800PBF3900PBF31000PBF31200PBF31400PBF31600PBF31800PBF32000
PBF32000FPBF32000FPBF32000FPBF32000FPBF32000FPBF32000FPBF32000FPBF32000FPBF32000FPBF32000F
PBF3600TPBF3700TPBF3800TPBF3900TPBF31000TPBF31200TPBF31400TPBF31600TPBF31800TPBF32000T
Special Calibrations➂
Special calibration price additions apply to ampere ratings not listed as standard, or for ambients other than 40°C or 50°C. See AD 29-160 for information regarding special conditions.
50°C Calibration➂➃
Add suffix “V” to catalogue number for complete breaker when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Type ofCalibration
1-24Identical Units
25 or MoreIdentical Units
Thermal➃Magnetic
Add 15% to ListPrice of Trip Unit
NoneNone
List Prices: See PAD (Price and Availability Digest)
PBF Front Connected
� Included with frame.� 2-pole breakers supplied in 3-pole frames with current carrying parts omitted from centre pole. � Not listed with CSA and Underwriters Laboratories Inc. � 50°C or higher calibration not available for 2500 ampere trip units.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Type PB 2500 Amperes (cont’d)
24 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Types LC, LCC, LCA, LCCA, MARK 75� Types HLC, HLCC, HLCA, HLCCA SELTRONIC�Circuit Breakers With Solid State Trip Units
600 Volts AC, 50/60 Hz Complete Breaker Requires Frame, Rating Plug and Terminals. Suitable for reverse feed application.
Frame Only
Poles➀
Standard (Long Delayand Magnetic Trip)
MagneticOnly➁
Long Delay, Magnetic Trip and Adjustable Short Delay Time
Catalogue Numbers
Breakers for Standard Applications
Types LC 150 and LCA 150 (75-150 Amps.)
23
LC2150FLC3150F
LC2150FMLC3150FM
LCA2150FLCA3150F
MARK 75 Types HLC 150 and HLCA 150 (75-150 Amps.)
23
HLC2150FHLC3150F
HLC2150FMHLC3150FM
HLCA2150FHLCA3150F
Types LC 300 and LCA 300 (150-300 Amps.)
23
LC2300FLC3300F
LC2300FMLC3300FM
LCA2300FLCA3300F
MARK 75 Types HLC 300 and HLCA 300 (150-300 Amps.)
23
HLC2300FHLC3300F
HLC2300FMHLC3300FM
HLCA2300FHLCA3300F
Types LC 400 and LCA 400 (200-400 Amps.)
23
LC2400FLC3400F
LC2400FMLC3400FM
LCA2400FLCA3400F
MARK 75 Types HLC 400 and HLCA 400 (200-400 Amps.)
23
HLC2400FHLC3400F
HLC2400FMHLC3400FM
HLCA2400FHLCA3400F
Types LC 600 and LCA 600 (300-600 Amps.)
23
LC2600FLC3600F
LC2600FMLC3600FM
LCA2600FLCA3600F
MARK 75 Types HLC 600 and HLCA 600 (300-600 Amps.)
23
HLC2600FHLC3600F
HLC2600FMHLC3600FM
HLCA2600FHLCA3600F
Type LC 600 Moulded Case Switch: Refer to Page 37
Breakers for Applications at 100% Rating
Types LCC 600 and LCCA 600 (300-600 Amps.)
3 LCC3600F LCCA3600F
MARK 75 Types HLCC 600 and HLCCA 600 (300-600 Amps.)
3 HLCC3600F HLCCA3600F
Field Mountable attachments➂➃➄➅
Description Style NumberProvision to trip flux transfer shunt trip from external source: 32 to 120 Volts (DC to 60 Hz)➆240 to 600 Volts AC (50/60 Hz)➇Provision to trip flux transfer shunt trip from external source, plus a 1A-1B auxiliary switch: 32 to 120 Volts (DC to 60 Hz)➆240 to 600 Volts AC (50/60 Hz)➇Provision to trip flux transfer shunt trip from 24 Volt DC source1A-1B Auxiliary Switch
1371D11G221371D11G32
1371D11G151371D11G251371D93G011371D11G03
� 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.� CSA and UL Inc. recognized component.� Only one attachment may be mounted per breaker.� For other possible combinations, refer to Eaton.� Moulded case switches do not use standard SELTRONIC attachments, and should be ordered by description for factory mounting.� Does not void listing of CSA and UL listed breakers.� Rated 48 volts minimum for ground fault applications requiring tripping at 55% of voltage. Not for use on ground fault applications. Interrupting capacities shown do not apply to moulded case switches (MCS).
Listed with CSA and Underwriters Laboratories Inc. except as noted.
On all 3 phase Delta, Grounded B phase applications, refer to Eaton.
Further InformationList Prices: See PAD (Price and Availability Digest)
Factory Mounted and Other Accessoriesand Modifications: Pages 39 - 49
Field Mountable attachments: This Page
Rating Plugs: Page 34
Portable Test Kit: Page 35
Terminals: Page 25
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings➈
Volts Max. AmperesStandard Breakers
240 AC480 AC600 AC
50,000 Asym., 42,000 Sym.35,000 Asym., 30,000 Sym.25,000 Asym., 22,000 Sym.
MARK 75� Breakers
240 AC480 AC600 AC
75,000 Asym., 65,000 Sym.40,000 Asym., 35,000 Sym.30,000 Asym., 25,000 Sym.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types LC, LCC, LCA, LCCA, MARK 75� Types HLC, HLCC, HLCA, HLCCA SELTRONIC� BreakersTypes LCG, LCCG, LCGA, LCCGA, MARK 75� Types HLCG, HLCCG, HLCGA, HLCCGA SELTRONIC� Breakers
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 25
494949494949494949494949494949494949494949494949494949494949
� Available without extra C.T. for neutral. Order by description as similar to above except without neutral C.T. or external C.T. terminal connections. (Same price). Note the standard ground fault unit above can also be used without the neutral C.T.
� These breakers use LC terminals. The fourth C.T. uses MC breaker terminals, page 28.� 2-pole breakers supplied in 3-pole frames with current carrying parts omitted from centre pole.� For applications other than standard residual scheme, see AD 29-160.� Type Al9Cu aluminum terminal.
Types LCG, LCCG, LCGA, LCCGA, MARK 75� HLCG, HLCCG, HLCGA, HLCCGA SELTRONIC� Breakers With Built-in Ground Fault Protection
Complete Breaker Requires Frame, Rating Plug, and Terminals, Extra Current Transformer Included for Neutral➀➁ See Accessories Page 35 for Indicator Kit. Suitable
for reverse feed application.
Frame OnlyGround FaultCharacteristics
Poles➂
Standard (Long Delay,Magnetic Trip) andGround Fault Trip
Long Delay, Magnetic Trip,Adjustable Short Delay Timeand Ground Fault Trip
Pick-upSettingAmps
TimeSettingCatalogue Numbers
Breakers for Standard Application
Types LCG 150 and LCGA 150 (75-150 Amps.)➃
3 LCG3150F LCGA3150F 50-150 3.5-30 Cy
MARK 75 Types HLCG 150 and HLCGA 150 (75-150 Amps.)➃
3 HLCG3150F HLCGA3150F 50-150 3.5-30 Cy
Types LCG 300 and LCGA 300 (150-300 Amps.)➃
3 LCG3300F LCGA3300F 60-300 3.5-30 Cy
MARK 75 Types HLCG 300 and HLCGA 300 (150-300 Amps.)➃
3 HLCG3300F HLCGA3300F 60-300 3.5-30 Cy
Types LCG 400 and LCGA 400 (200-400 Amps)➃
3 LCG3400F LCGA3400F 80-400 3.5-30 Cy
MARK 75 Types HLCG 400 and HLCGA 400 (200-400 Amps.)➃
3 HLCG3400F HLCGA3400F 80-400 3.5-30 Cy
Types LCG 600 and LCGA 600 (300-600 Amps.)➃
3 LCG3600F LCGA3600F 120-600 3.5-30 Cy
MARK 75 Types HLCG 600 and HLCGA 600 (300-600 Amps.)➃
3 HLCG3600F HLCGA3600F 120-600 3.5-30 Cy
Breakers for Application at 100% Rating
Types LCCG 600 and LCCGA 600 (300-600 Amps.)➃
3 LCCG3600F LCCGA3600F 120-600 3.5-30 Cy
MARK 75 Types HLCCG 600 and HLCCGA 600 (300-600 Amps.)➃
3 HLCCG3600F HLCCGA3600F 120-600 3.5-30 Cy
Terminals (Order Separately)
Two terminals are required per pole. Terminals are CSA and UL Inc. listed for wire type and range listed below. When used with aluminum cable, use joint compound.
Further InformationList Prices: See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories and Modifications: Pages 39 - 49
Field Mountable Attachments: Page 24
Rating Plugs: Page 34
Portable Test Kit: Page 35
Remote Ground Fault Trip Indicator: Pg 35
Max.Amps.
TerminalCat. No.
Wire Range, typeNo. of Cables
150, 300, and 400 Amp Frames Only
Al/Cu Pressure Terminals
225
400
TA225LA1
TA400LA1
(1) #6-350 MCM Cu, or(1) #4-350 MCM Al(1) #4-250 MCM Al/Cu, plus(1) 3/0-600 MCM Al/Cu
Copper Pressure Terminals
225225400
T225LAT225LBFT401LA
(1) #6-350 MCM Cu(1) #6-250 MCM Cu(1) #4-250 MCM Cu, plus(1) 3/0-600 MCM Cu
600 Amp Frame Only
Al/Cu Pressure Terminals
500600600
TA602LD➄TA603LA➄TA600LA➄
(2) 250-350 MCM Al/Cu(2) 400-500 MCM Al/Cu(2) 250-500 MCM Al/Cu
Copper Pressure Terminals
600 T600LA (2) 250-500 MCM Cu
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types LC, LCC, LCA, LCCA, MARK 75� Types HLC, HLCC, HLCA, HLCCA SELTRONIC� BreakersTypes LCG, LCCG, LCGA, LCCGA, MARK 75� HLCG, HLCCG, HLCGA, HLCCGA SELTRONIC� Breakers
26 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Types LCY and LCYA SELTRONIC� Circuit Breakers with Solid State Trip Units.
240 Volts AC, 50/60 Hz Complete Breaker Requires Frame, Rating Plug and Terminals. Suitable for reverse feed application.
Frame Only
Poles
Standard (Long Delayand Magnetic Trip)
Long Delay, Magnetic Trip and AdjustableShort Delay Time
Catalogue NumbersTypes LCY and LCYA (300-600 Amperes)
3 LCY3600F LCYA3600F
Types LCYG and LCYGA SELTRONIC� Breakers with Built-in Ground Fault Protection
Complete Breaker Requires Frame, Rating Plug, and Terminals, Extra Current Transformer Included for Neutral➀➁ See Accessories Page 35 for Indicator Kit. Suitable
for reverse feed application.
Frame Only Ground FaultCharacteristics
Poles
Standard (Long Delay,Magnetic Trip) andGround Fault Trip
Long Delay, Magnetic Trip,Adjustable Short Delay Timeand Ground Fault Trip
Pick-upSettingAmps
TimeSettingCatalogue Numbers
Types LCYG, LCYGA (300-600 Amperes)
3 LCYG3600F LCYGA3600F 120-600 3.5-30 Cy
Field Mountable attachments➄➅➆
Description Style Number
Provision to trip flux transfer shunt trip from external source: 32 to 120 Volts (DC to 60 Hz)➇240 to 600 Volts AC (50/60 Hz)➈Provision to trip flux transfer shunt trip from external source, plus a 1A-1B AuxiliarySwitch: 32 to 120 Volts (DC to 60 Hz)➇240 to 600 Volts AC (50/60 Hz)➈Provision to trip flux transfer shunt trip from 24-Volt DC source1A-1B Auxiliary Switch
1371D11G221371D11G32
1371D11G151371D11G251371D93G011371D11G03
� Available without extra C.T. for neutral. Order by description as similar to above except without neutral C.T. or external C.T. terminal connections (Same Price). Note the standard ground fault unit above can also be used without the neutral C.T.
� These breakers use LC terminals. The fourth C.T. uses MC breaker terminals.� For 600 amp frame breakers only.� Type Al9Cu aluminum terminal.� Only one attachment may be mounted per breaker.� For other possible combinations, refer to Eaton.� Does not void listing of UL listed breakers. Rated 48 volts minimum for ground fault applications requiring tripping at 55% of voltage. Not for use on ground fault applications.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
Type LCY breakers are not defined by Federal Specification W-C-375b.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Volts Max. Amperes240 AC 115,000 Asym., 100,000 Sym.
On all 3 phase Delta, Grounded B phaseapplications, refer to Eaton.
Further InformationList Prices: See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories and Modifications: Pages 39 - 49
Field Mountable Attachments: This Page
Rating Plugs: Page 34
Portable Test Kit: Page 35
Terminals (Order Separately)
Two terminals are required per pole. Terminals are UL Inc. listed for wire type and range listed at right. When used with aluminum cable, use joint compound.
Max.Amps.
TerminalCat. Number
Wire Range, TypeNo. of Cables
Standard Al/Cu Pressure Terminals
500➂600➂600➂
TA602LD➃TA603LA➃TA600LA➃
(2) 250-350 MCM Al/Cu(2) 400-500 MCM Al/Cu(2) 250-500 MCM Al/Cu
Optional Copper Pressure Terminals
600➂ T600LA (2) 250-500 MCM Cu
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types LCY, LCYA, LCYG and LCYGA, 240 Volts AC, 3-Pole 300-600 Amperes SELTRONIC� Breakers
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 27
494949494949494949494949494949494949494949494949494949494949
Types MC, MCC, MCA, MCCA, MARK 75® Types HMC, HMCC, HMCA, HMCCA SELTRONIC� Circuit Breakers with Solid State Trip Units
600 Volts AC, 50/60 Hz Complete Breaker Requires Frame, Rating Plug, and Terminals, Suitable for reverse feed application.
Frame Only
Poles➀
Standard (Long Delayand Magnetic Trip)
MagneticOnly➁
Long Delay, Magnetic Trip and AdjustableShort Delay Time
Catalogue Numbers
Breakers for Standard Application
Types MC and MCA 400 to 800 Amps.
23
MC2800FMC3800F
MC2800FMMC3800FM
MCA2800FMCA3800F
MARK 75� Types HMC and HMCA 400 to 800 Amps.
23
HMC2800FHMC3800F
HMC2800FMHMC3800FM
HMCA2800FHMCA3800F
Type MC800 Moulded Case Switch: Refer to Page 37
Breakers for Application at 100% Rating
Types MCC and MCCA 400 to 800 Amps.
3 MCC3800F MCCA3800F
MARK 75� Types HMCC and HMCCA 400 to 800 Amps.
3 HMCC3800F HMCCA3800F
Types MCG, MCCG, MCGA, MCCGA and MARK 75� Types HMCG, HMCCG, HMCGA, HMCCGA SELTRONIC� Circuit Breakers With Built-in Ground Fault Protection
Complete Breaker Requires Frame, Rating Plug and Terminals – Extra Current Transformer Included for Neutral➂➃ See Page 35 For Optional Indicator Kit
Frame OnlyGround FaultCharacteristics
Poles
Standard (Long Delay,Magnetic and GroundFault Trip)
Long Delay, Magnetic Trip,Adjustable Short Delay Timeand Ground Fault Trip
Pick-upSettingAmps
TimeSettingCatalogue Numbers
Breakers for Standard Applications
Types MCG and MCGA 400 to 800 Amps.➄
3 MCG3800F MCGA3800F 80-800 3.5-30 Cy
MARK 75� Types HMCG and HMCGA 400 to 800 Amps.➄
3 HMCG3800F HMCGA3800F 80-800 3.5-30 Cy
Breakers for Applications at 100% Rating
Types MCCG and MCCGA 400 to 800 Amps.➄
3 MCCG3800F MCCGA3800F 80-800 3.5-30 Cy
MARK 75� Types HMCCG and HMCCGA 400 to 800 Amps.➄
3 HMCCG3800F HMCCGA3800F 80-800 3.5-30 Cy
Listed with CSA and Underwriters Laboratories Inc. except as noted.
CSA and UL Listed Interrupting Capacity, RMS Symmetrical Amperes➅
Further InformationList Prices: See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories and Modifications: Pages 39 - 49
Field Mountable Attachments: Page 28
Rating Plugs: Page 34
Portable Test Kit: Page 35
Remote Ground Fault Trip Indicator: Pg 35
BreakerAC Volts240 480 600
MC, MCGHMC, HMCG
4200065000
3000050000
2200025000
� Two pole breakers are supplied in 3-pole frames with current-carrying parts omitted from centre pole.� CSA and UL Inc. recognized component.� Available without extra C.T. for neutral. Order by description as similar to above except without neutral C.T. or external C.T. Terminal connections. (Same Price)
Note: the standard ground fault unit above can also be used without the neutral C.T.� Order two of the desired terminals for each pole of the breaker and two for the neutral C.T.� For applications other than standard residual scheme, see AD 29-160.� Interrupting capacities shown do not apply to moulded case switches (MCS).
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types MC, MCC, MCA, MCCA, MCG, MCCG, MCGA, MCCGA and MARK 75� Types HMC,HMCC, HMCCA, HMCA, HMCG, HMCCG, HMCGA, HMCCGA 800 Ampere SELTRONIC� Breakers
28 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
� Does not void listing of CSA and UL listed breakers.� Only one of the attachments may be mounted per breaker.� For other possible combinations, refer to Eaton.� Moulded case switches do not use standard SELTRONIC� attachments and should be ordered by description.� Rated 48 volts minimum for ground fault applications requiring tripping at 55% of voltage.� Not for Ground Fault Applications.� Also used on breakers with ground fault and on separately mounted neutral current transformers. Type Al9Cu aluminum terminal.
Replacement AB DE-ION ® Circuit Breakers
Types MC, MCC, MCA, MCCA, MCG, MCCG, MCGA, MCCGA and MARK 75� Types HMC, HMCC, HMCA, HMCCA, HMCG, HMCCG, HMCGA, HMCCGA 800 Ampere SELTRONIC� Breakers
Field Mountable Attachments➀➁➂➃
Description Style NumberProvision to trip flux transfer shunt trip from external source: 32 to 120 Volts (DC to 60 Hz)➄240 to 600 Volts AC 50/60 Hz➅Provision to trip flux transfer shunt trip from external source, plus 1A-1B AuxiliarySwitch: 32 to 120 Volts (DC to 60 Hz)➄240 to 600 Volts AC (50/60 Hz)➅Provision to trip flux transfer shunt trip from external 24-Volt DC source1A-1B Auxiliary Switch
1371D72G221371D72G32
1371D72G151371D72G251370D85G011371D72G03
Terminals (Two Required per Pole)➆
Max.Amps.
TerminalCat. No. No., Size of Cable
Al/Cu Pressure Terminals
600800800
TA700MA1➇TA800MA2➇TA801MA➇
(2) #1-500 MCM(3) 3/0-400 MCM(2) 500-750 MCM
Copper Only Pressure Terminals
600800
T600MA1T800MA1
(2) 2/0-500 MCM(3) 3/0-300 MCM
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 29
494949494949494949494949494949494949494949494949494949494949
Types MCY and MCYA SELTRONIC� Circuit Breakers with Solid State Trip Units
240 Volts AC, 50/60 Hz Complete Breaker Requires Frame, Rating Plug and Terminals. Suitable for reverse feed application.
Frame Only
Poles
Standard (Long Delayand Magnetic Trip)
Long Delay, Magnetic Trip and AdjustableShort Delay Time
Catalogue NumbersTypes MCY and MCYA (400-800 Amperes)
3 MCY3800F MCYA3800F
Types MCYG and MCYGA SELTRONIC� Circuit Breakers with Built-in Ground Fault Protection
Complete Breaker Requires Frame, Rating Plug, and Terminals – Extra Current Transformer Included for Neutral➀➁ See Page 35 for Indicator Kit. Suitable for reverse
feed application.
Frame Only Ground FaultCharacteristics
Poles
Standard (Long Delay,Magnetic andGround Fault Trip)
Long Delay, Magnetic Trip,Adjustable Short Delay Timeand Ground Fault Trip Pick-up
SettingAmps
TimeSettingCatalogue Numbers
Types MCYG and MCYGA (400-800 Amperes)➂
3 MCYG3800F MCYGA3800F 80-800 3.5-30 Cy
Field Mountable attachments➅➆➇
Description Style NumberProvision to trip flux transfer shunt trip from external source: 32 to 120 Volts (DC to 60 Hz)➈240 to 600 Volts AC (50/60 Hz)➉Provision to trip flux transfer shunt trip from external source, plus 1A-1B AuxiliarySwitch: 32 to 120 Volts (DC to 60 Hz)➈240 to 600 Volts AC (50/60 Hz)➉Provision to trip flux transfer shunt trip from external 24-Volt DC source1A-1B Auxiliary Switch
1371D72G221371D72G32
1371D72G151371D72G251370D85G011371D72G03
Listed with CSA and Underwriters Laboratories Inc. except as noted.
Type MCY breakers are not defined byFederal Specification W-C-375b.
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Max. Volts Amperes240 AC 115,000 Asym., 100,000 Sym.
Further InformationList Prices: See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories and Modifications: Pages 39 - 49
Field Mountable Attachments: This Page
Rating Plugs: Page 34
Portable Test Kit: Page 35
Remote Ground Fault Trip Indicator: Pg 35
� Available without extra C.T. for neutral. Order by description as similar to above except without neutral C.T. or external C.T. Terminal connections. (Same Price) Note: the standard ground fault unit above can also be used without the neutral C.T.
� Order two of the desired terminals for each pole of the breaker and two for the neutral C.T.� For applications other than standard residual scheme, see AD 29-160.� Also used on breakers with ground fault and on separately mounted neutral current transformers.� Type Al9Cu aluminum terminal.� Does not void listing of CSA and UL listed breakers.� Only one of the attachments may be mounted per breaker. For other possible combinations, refer to Eaton. Rated 48 volts minimum for ground fault applications requiring tripping at 55% of voltage.� Not for ground fault applications.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION ® Circuit Breakers
Types MCY, MCYA, MCYG and MCYGA SELTRONIC� Breakers
Terminals (Two Required per Pole)➃
Max.Amps.
TerminalCat. No.
No., Size of Cable,Type
Al/Cu Pressure Terminals
600800800
TA700MA1➄TA800MA2➄TA801MA➄
(2) #1-500 MCM Al/Cu(3) 3/0-400 MCM Al/Cu(2) 500-750 MCM Al/Cu
Copper Only Pressure Terminals
600800
T600MA1T800MA1
(2) 2/0-500 MCM Cu(3) 3/0-300 MCM Cu
30 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Types NC, NCA, MARK 75® Type HNC, HNCA SELTRONIC� Circuit Breakers with Solid State Trip Units
Types NCG, NCGA, and MARK 75® Type HNCG, HNCGA SELTRONIC� Circuit Breakers with Built-in Ground Fault Protection
600 Volts AC, 50/60 Hz Complete Breaker Requires Frame, Rating Plug, and Terminals.Suitable for reverse feed application.
Frame Only
Poles➀
Standard (Long Delayand Magnetic Trip)
MagneticOnly➁
Long Delay, Magnetic Trip andAdjustable Short Delay Time
Catalogue NumbersTypes NC and NCA 800 to 1200 Amps
23
NC21200FNC31200F
NC21200FMNC31200FM
NCA21200FNCA31200F
Mark 75 Types HNC and HNCA 800 to 1200 Amps
23
HNC21200FHNC31200F
HNC21200FMHNC31200FM
HNCA21200FHNCA31200F
Type NC 1200 Moulded Case Switch: Refer to Page 37
Complete Breaker Requires Frame, Rating Plug and Terminals – Extra Current Transformer Included for Neutral➂➃ See Page 35 for Optional Indicator Kit. Suitable for reverse feed application.
Frame Only Ground Fault Characteristics
Poles
Standard (Long Delay,Magnetic and GroundFault Trip)
Long Delay, Magnetic Trip,Adjustable Short Delay Time,and Ground Fault Trip
Pick-upSettingAmps
TimeSettingCatalogue Numbers
Types NCG and NCGA 800 to 1200 Amperes➄
3 NCG31200F NCGA31200F 120-1200 3.5-30 Cy
Mark 75 Types HNCG and HNCGA 800 to 1200 Amperes➄
3 HNCG31200F HNCGA31200F 120-1200 3.5-30 Cy
Field Mountable attachments➅➆➇➈
Description Style NumberProvision to trip flux transfer shunt trip from external source: 32 to 120 Volts (DC to 60 Hz)➉240 to 600 Volts AC (50/60 Hz)�Provision to trip flux transfer shunt trip from external source, plus a 1A-1B auxiliary switch: 32 to 120 Volts (DC to 60 Hz)➉240 to 600 Volts AC (50/60 Hz)�Provision to trip flux transfer shunt trip from external 24-volt DC source1A-1B Auxiliary Switch
1372D39G131372D39G23
1372D39G161372D39G261372D94G051372D39G03
� 2-pole breakers are supplied in 3-pole frames with current-carrying parts omitted from centre pole.� CSA and UL Inc. recognized component.� Available without extra C.T. for neutral. Order by description as similar to above except without neutral C.T. or external C.T. Terminal connections. (Same Price)
Note: the standard ground fault unit above can also be used without the neutral C.T.� Order two of the desired terminals for each pole of the breaker and two for the neutral C.T.� For applications other than standard residual scheme, see AD 29-160.� For other possible combinations, refer to Eaton.� Moulded case switches do not use standard SELTRONIC attachments and should be ordered by description. Does not void listing of CSA and UL listed breakers. Only one of the attachments may be mounted per breaker.� Rated 48 volts minimum for ground fault applications requiring tripping at 55% of voltage.� Not for ground fault applications.� Also used on breakers with ground fault and on separately mounted neutral current transformers.� Type Al9Cu aluminum terminal.� Type Al7Cu aluminum terminal.� Interrupting capacities shown do not apply to moulded case switches (MCS).
Replacement AB DE-ION ® Circuit Breakers
Type NC, NCA, NCG, NCGA and MARK 75� Type HNC, HNCA, HNCG, HNCGA 1200 Ampere SELTRONIC� Breakers
Listed with CSA and Underwriters Laboratories Inc. except as noted.
Further InformationList Prices: See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories and Modifications: Pages 39 - 49
Field Mountable attachments: This Page
Rating Plugs: Page 34
Portable Test Kit: Page 35
Remote Ground Fault Trip Indicator: Pg. 35
CSA and UL Listed Interrupting Capacity, RMS Symmetrical Amperes�
BreakerAC Volts240 480 500
NC, NCGHNC, HNCG
4200065000
3000050000
2200025000
Terminals (Two Required per Pole)�
Max.Amps
TerminalCat. No. No., Size of Cable
Al/Cu Pressure Terminals
100012001200
TA1000NB1�
TA1200NB1�
TA1201NB1�
(3) 3/0-400MCM(4) 4/0-500MCM(3) 500-750MCM
Copper Only Pressure Terminals
10001200
T1000NB1T1200NB1
(3) 3/0-500MCM(4) 3/0-400MCM
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
31
494949494949494949494949494949494949494949494949494949494949
Types NCY and NCYA SELTRONIC
�
Circuit Breakers with Solid State Trip UnitsSuitable for reverse feed application
Frame Only
Poles
Standard (Long Delayand Magnetic Trip)
Long Delay, Magnetic Trip and AdjustableShort Delay Time
Catalogue Numbers
Types NCY and NCYA 800 to 1200 Amperes
3
NCY31200F NCYA31200F
Type NCYG, NCYGA SELTRONIC™ Breakers with Built-in Ground Fault Protection
Complete Breaker Requires Frame, Rating Plug, and Terminals – Extra Current Transformer Included for Neutral
��
See Page 35 for Optional Indicator Kit
Frame Only
Ground FaultCharacteristics
Poles
Standard (Long Delay,Magnetic Trip) andGround Fault Trip
Long Delay, Magnetic Trip,Adjustable Short Delay Time andGround Fault Trip
Pick-upSetting(Amps)
TimeSettingCatalogue Numbers
Types NCYG and NCYGA 800 to 1200 Amperes
➂
3
NCYG31200F NCYGA31200F
120-1200 3.5-30 Cy
Terminals
(Two Required per Pole)
➃
Max.Amps
TerminalCat. No.
No., Size of Cable,Type
Al/Cu Pressure Terminals
100012001200
TA1000NB1
➄
TA1200NB1
➄
TA1201NB1
➅
(3) 3/0-400 MCM Al/Cu(4) 4/0-500 MCM Al/Cu(3) 500-750 MCM Al/Cu
Copper Only Pressure Terminals
10001200
T1000NB1T1200NB1
(3) 3/0-500 MCM Cu(4) 3/0-400 MCM Cu
Field Mountable Attachments
➆➇➈
Description Style Number
Provision to trip flux transfer shunt trip from external source: 32 to 120 Volts (DC to 60 Hz)
➉
240 to 600 Volts AC (50/60 Hz)
�
Provision to trip flux transfer shunt trip from external source, plus a 1A-1B AuxiliarySwitch: 32 to 120 Volts (DC to 60 Hz)
➉
240 to 600 Volts AC (50/60 Hz)
�
Provision to trip flux transfer shunt trip from external 24-volt DC source1A-1B Auxiliary Switch
1372D39G131372D39G23
1372D39G161372D39G261371D94G051372D39G03
�
Available without extra C.T. for neutral. Order by description as similar to above except without neutral C.T. or external C.T. Terminal connections. (Same Price)Note: the standard ground fault unit above can also be used without the neutral C.T.
�
Order two of the desired terminals for each pole of the breaker and two for the neutral C.T.
�
For applications other than standard residual scheme, see AD 29-160.
�
Also used on breakers with ground fault and on separately mounted neutral current transformers.
�
Type Al9Cu aluminum terminal.
�
Type Al7Cu aluminum terminal.
�
Does not void listing of CSA and UL listed breakers.
Only one of the attachments may be mounted per breaker.
For other possible combinations, refer to Eaton.
�
Rated 48 volts minimum for ground fault applications requiring tripping at 55% of voltage.
�
Not for ground fault applications.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
Type NCY breakers are not defined by Federal Specification W-C-375b.
Further Information
List Prices:
See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories
and Modifications:
Pages 39 - 49
Field Mountable Attachments:
This Page
Rating Plugs:
Page 34
Portable Test Kit:
Page 35
Remote Ground Fault Trip Indicator:
Pg. 35
CSA and Underwriters Laboratories Inc. Listed Interrupting Ratings
Volts Max. Amperes
240 AC 115,000 Asym., 100,000 Sym.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Types NCY, NCYA, NCYG, NCYGA SELTRONIC
�
Breakers
32 Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Drawout Mounting Breakers, 3-Pole Only
Breaker frame and complete drawout frame with safety tripping interlock. Order by description. Secondary contacts supplied as required at no extra charge. Order required rating plug separately. Refer to page 49.
Stationary Portion of Drawout Frame Only for Future Breaker Installations,3-Pole Only.
Refer to page 49.
Special Type PCC Breakers for SCR Power Supplies
These drawout mounting breakers are designed with a 2 to 4 times magnetic trip adjustment and special time delay trip characteristics to provide maximum protection and coordination with SCR power supplies on offshore drilling rigs. Suitable for application at 100% of rating.
Order by description. Secondary contacts supplied as required. Order standard rating plugs separately.
Availability: PCC2000, PCC2500 Drawout-Mounting breakers. See page 49.
Listed with CSA and Underwriters Laboratories Inc. except as noted.
CSA and UL Listed Interrupting Capacity RMS Symmetrical Amperes
(Std. and Grd. Flt. Breakers)
➄
Breaker
AC Volts
240 480 600
PC, PCC 125,000 100,000 100,000
Types PC, PCC Moulded Case Switches: Refer to Page 37
�
2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from centre pole.
�
CSA and UL Inc. recognized component.
�
CSA and UL listed for standard applications.
�
These breakers are CSA and UL Listed for application at 100% of rating per NEC exceptions when used in a properly ventilated and listed enclosure.
�
Interrupting capacities shown do not apply to moulded case switches (MCS).
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Types PC, PCA, PCC, PCCA 2000, 2500 and 3000 Amperes SELTRONIC
�
Breakers
Types PC, PCA, PCC, PCCA 2000, 2500 and 3000 Ampere SELTRONIC
�
Circuit Breakers With Solid State Trip Units, 600 Volts AC, 50/60 Hz
Complete Breaker Requires Frame, Rating Plug and Rear Connectors (connectors are included in 3000 Amp and all front connected frames.)
Suitable for reverse feed application.
Breakers for Standard Applications Breakers for Standard Applications at 100% RatingFrame Only Frame Only
Poles
➀
Standard(Long Delayand Magnetic Trip)
MagneticOnly
➁
Long Delay, Magnetic Trip,and Adjustable Short DelayTime
Poles
➀
Standard(Long Delayand Magnetic Trip)
MagneticOnly
➁
Long Delay, Magnetic Trip,and Adjustable Short DelayTime
Catalogue Numbers Catalogue Numbers
Type PC 2000, 1000 to 2000 Amps
➂
Type PCA 2000
➂
Type PCC 2000, 1000 to 2000 Amps
➃
Type PCCA 2000
➃
Rear Connected BreakersRear Connected Breakers Rear Connected Breakers Rear Connected Breakers
23
PC22000FPC32000F
PC22000FMPC32000FM
PCA22000FPCA32000F
23
PCC22000FPCC32000F
PCC22000FMPCC32000FM
PCCA22000FPCCA32000F
Front Connected BreakersFront Connected Breakers Front Connected Breakers Front Connected Breakers
23
PCF22000FPCF32000F
PCF22000FMPCF32000FM
PCFA22000FPCFA32000F
23
PCCF22000FPCCF32000F
PCCF22000FMPCCF32000FM
PCCFA22000FPCCFA32000F
Type PC 2500, 1400 to 2500 Amps
➂
Type PCA 2500
➂
Type PCC 2500, 1400 to 2500 Amps
➃
Type PCCA 2500
➃
Rear Connected BreakersRear Connected Breakers Rear Connected Breakers Rear Connected Breakers
23
PC22500FPC32500F
PC22500FMPC32500FM
PCA22500FPCA32500F
23
PCC22500FPCC32500F
PCC22500FMPCC32500FM
PCCA22500FPCCA32500F
Front Connected BreakersFront Connected Breakers Front Connected Breakers Front Connected Breakers
23
PCF22500FPCF32500F
PCF22500FMPCF32500FM
PCFA22500FPCFA32500F
23
PCCF22500FPCCF32500F
PCCF22500FMPCCF32500FM
PCCFA22500FPCCFA32500F
Type PC 3000, 1600 to 3000 Amps
➂
Type PCA 3000
➂
Type PCC 3000, 1600 to 3000 Amps
➃
Type PCCA 3000
➃
23
PC23000FPC33000F
PC23000FMPC33000FM
PCA23000FPCA33000F
23
PCC23000FPCC33000F
PCC23000FMPCC33000FM
PCCA23000FPCCA33000F
Further Information
List Prices:
See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories
and Modifications:
Pages 39 - 49
Field Mountable Attachments:
Page 33
Rating Plugs:
Page 34
Portable Test Kit:
Page 35
Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
33
494949494949494949494949494949494949494949494949494949494949
Types PCG, PCGA, PCCG, PCCGA SELTRONIC
�
Breakers With Built-in Ground Fault Protection Includes Extra Current Transformer for Neutral
➀
(Optional Indicator Kit Page 35)
Breakers for Standard Application
Complete Breaker Requires Frame, Rating Plug and Rear Connectors (except Front Connected Frames and 3000 Amp Frames Include Connectors)
Frames Only Ground Fault Characteristics
Poles
Standard (Long Delay, Magnetic and Ground Fault Trip)
Long Delay, Magnetic, Ground Fault Trip, and Adjustable Short Delay Time
Pick-upSetting
TimeSettingCatalogue Numbers
Type PCG 2000
➁➂
Type PCGA 2000
➁➂
1000 to 2000 Amps
➂
Rear Connected Breakers
3
PCG32000F PCGA32000F
200-1200 3.5-30 Cy
Front Connected Breakers
3
PCFG32000F PCFGA32000F
200-1200 3.5-30 Cy
Type PCG 2500
➁➂
Type PCGA 2500
➁➂
1400 to 2500 Amps
➂
Rear Connected Breakers
3
PCG32500F PCGA32500F
240-1200 3.5-30 Cy
Front Connected Breakers
3
PCFG32500F PCFGA32500F
240-1200 3.5-30 Cy
Type PCG 3000
➁➂
Type PCGA 3000
➁➂
1600 to 3000 Amps
➂
3
PCG33000F PCGA33000F
300-1200 3.5-30 Cy
Breakers for Application at 100% Rating
Frames Only Ground Fault Characteristics
Poles
Standard (Long Delay, Magnetic and Ground Fault Trip)
Long Delay, Magnetic, Ground Fault Trip, and Adjustable Short Delay Time
Pick-upSetting
TimeSettingCatalogue Numbers
Type PCCG 2000
➃
Type PCCGA 2000
➃
1000 to 2000 Amps
➂
Rear Connected Breakers
3 PCCG32000F PCCGA32000F 200-1200 3.5-30 Cy
Front Connected Breakers
3 PCCFG32000F PCCFGA32000F 200-1200 3.5-30 Cy
Type PCCG 2500
➃
Type PCCGA 2500
➃
1400 to 2500 Amps
➂
Rear Connected Breakers
3 PCCG32500F PCCGA32500F 240-1200 3.5-30 Cy
Front Connected Breakers
3 PCCFG32500F PCCFGA32500F 240-1200 3.5-30 Cy
Type PCCG 3000
➃
Type PCCGA 3000
➃
1600 to 3000 Amps
➂
3 PCCG33000F PCCGA33000F 300-1200 3.5-30 Cy
Field Mountable Attachments
➄➅➆
Description Style Number
Provision to trip flux transfer shunt trip from external source: 32 to 120 Volts (DC to 60 Hz)
➇
240 to 600 Volts AC (50/60 Hz)
➈
Provision to trip flux transfer shunt trip from external source plus 1A-1B Auxiliary Switch: 32 to 120 Volts (DC to 60 Hz)
➇
240 to 600 Volts AC (50/60 Hz)
➈
Provision to trip flux transfer shunt trip from external 24-volt DC source1A-1B Auxiliary Switch
1372D35G221372D35G32
1372D35G151372D35G251371D95G011372D35G03
Modifications and Accessories
Bus Bar Connections
�
“T” Connector(For Cu/AI Bus)
Two required per pole. Forrear bus connection ofbreakers through 2000 Amps.Accepts up to four bus bolts.May be rotated 90°.
Catalogue Number BA2000PB
“C” Connector(For Cu/AI Bus)
Two required per pole. For rear bus connection of breakers through 2500 amps.
Catalogue Number BA2500PB
Cable Connector
Fits “T” Connector and 2000amp front connectedbreakers. Accepts four 250-600 MCM copper cables.
Style Number 505C706G04
Racking Crank for Drawout FramesTo engage or withdraw the moving portion of the drawout. A standard 1⁄2 inch hex socket with extension can be used for this purpose.
Style No. 765A767G01.
Cell Switches Mounted on Drawout Frames, All RatingsA maximum of four switches can be provided. Order by description. Each switch provides a NO and NC contact that transfers before reaching the test position when being withdrawn, and after the test position when being racked in.
Further InformationList Prices: See PAD (Price and Availability Digest)
Factory Mounted and Other Accessories and Modifications: Pages 39 - 49
Field Mountable Attachments: This Page
Rating Plugs: Page 34
Portable Test Kit: Page 35
Remote Ground Fault Trip Indicator: Pg 35
Replacement AB DE-ION® Circuit Breakers
Type PCG, PCGA, PCCG, PCCGA SELTRONIC� Breakers with Built-in Ground Fault Protection
� Available without external C.T. for neutral. Order by description and specify similar to above except no neutral C.T. or terminal connections for neutral C.T. (Same Price) Note: the standard ground fault unit listed above can also be used without the neutral C.T.
� CSA and UL listed for standard applications.� For application other than standard residual schemes, refer to AD 29-160.� These breakers are UL listed for application at 100% of rating per NEC exceptions when used in a properly ventilated and listed enclosure.� For other possible combinations, refer to Eaton.� Does not void listing of CSA and UL Listed Breakers.� Only one of these attachments may be mounted per breaker. Rated 48 volts minimum for Ground Fault applications. Not for ground fault applications.� Shipped separately from breaker.
Shaded gray areas denotes obsolete or discontinued products and services
34 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
� Ampere rating when used in magnetic only frames:LC-150: 150 Amps LC-600: 600 Amps PC-2000: 2000 AmpsLC-300: 300 Amps MC-800: 800 Amps PC-2500: 2500 AmpsLC-400: 400 Amps NC-1200: 1200 Amps PC-3000: 3000 Amps
� Magnetic Trip range of adjustable rating plugs:LC, HLC, MC, HMC: 3 to 10 times ampere settingNC, HNC, PC, PCC: 2 to 8 times ampere setting
� Adjustable 70 to 100% except as noted.� Adjustable 75 to 100%� Adjustable 50 to 100%� Adjustable 80 to 100%
Replacement AB DE-ION® Circuit Breakers
Rating Plugs for SELTRONIC� Breakers
Rating Plug Selection Data
Rating Plugs Listed Below Are For Both Standard Breakers and Breakers with Built-in Ground Fault Protection
Rating Plugs Only (For 2 or 3-Pole Frames)
ContinuousAmpereRating➀
Magnetic Trip Setting, Amperes Fixed Rating Plugs
Adjustable Rating Plugs➁➂
Low High Catalogue NumberFor 150 Amp, Frames: LC, LCA, LCG, LCGA, HLC, HLCA, HLCG, HLCGA
75 90 100 125 150
225 270 300 375 450
750 900100012501500
1LC751LC901LC1001LC1251LC150
A1LC100➃A1LC125A1LC150➄
For 300 Amp. Frames: LC, LCA, LCG, LCGA, HLC, HLCA HLCG, HLCGA
150 175 200 225 250 275 300
450 525 600 675 750 825 900
1500175020002250250027503000
3LC1503LC1753LC2003LC2253LC2503LC2753LC300
A3LC225A3LC250A3LC275A3LC300➄
For 400 Amp. Frames: LC, LCA, LCG, LCGA, HLC, HLCA, HLCG, HLCGA
200 225 250 300 350 400
600 675 750 90010501200
200022502500300035004000
4LC2004LC2254LC2504LC3004LC3504LC400
A4LC300A4LC350A4LC400➄
For 600 Amp. Frames: LC, LCA, LCG, LCGA, HLC, HLCA, HLCG, HLCGA, LCC, LCCA, HLCC, HLCCA, LCCG, LCCGA, HLCCG, HLCCGA
300 350 400 450 500 600
90010501200135015001800
300035004000450050006000
6LC3006LC3506LC4006LC4506LC5006LC600
A6LC400➃A6LC450A6LC500A6LC600➄
For 800 Amp. Frames: MC, MCA, MCG, MCGA, HMC, HMCA, HMCG, HMCGA, MCC, MCCA, HMCC, HMCCA, MCCG, MCCGA, HMCCG, HMCCGA
400 500 600 700 800
12001500180021002400
40005000600070008000
8MC4008MC5008MC6008MC7008MC800
A8MC500➅A8MC600A8MC700A8MC800➄
For 1200 Amp. Frames: NC, NCA, NCG, NCGA, HNC, HNCA, HNCG, HNCGA
800 90010001200
1600180020002400
6400720080009600
12NC80012NC90012NC100012NC1200
A12NC800➃A12NC900A12NC1000A12NC1200➄
Note: Refer to Eaton for old style (three prong) ground fault rating plugs.
Further InformationList Prices: See PAD (Price and Availability Digest)
Rating Plugs Only (For 2 or 3-Pole Frames)
ContinuousAmpereRating➀
Magnetic Trip Setting, Amperes Fixed Rating Plugs
Adjustable Rating Plugs➁➂
Low High Catalogue NumberFor 2000 Amp. Frames: PC, PCA, PCC, PCCA, PCG, PCGA, PCCG, PCCGA, PCF, PCCF
100012001400160018002000
200024002800320036004000
8000 960011200128001440016000
20PC100020PC120020PC140020PC160020PC180020PC2000
A20PC1600A20PC1800A20PC2000➄
For 2500 Amp. Frames: PC, PCA, PCC, PCCA, PCG, PCGA, PCCG, PCCGA
14001600180020002500
28003200360040005000
1120012800144001600020000
25PC140025PC160025PC180025PC200025PC2500
A25PC1800A25PC2000A25PC2500➄
For 3000 Amp. Frames: PC, PCA, PCC, PCCA, PCG, PCGA, PCCG, PCCGA
16001800200025003000
32003600400050006000
1280014400160002000024000
30PC160030PC180030PC200030PC250030PC3000
A30PC2500A30PC3000➄
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 35
494949494949494949494949494949494949494949494949494949494949
Portable Test KitProvides verification of performance of all frame sizes of SELTRONIC� breakers while devices are still in service under varying load and/or phase unbalance. The tester operates on 120-volt 50/60 Hz and includes complete instructions and test times for testing the long time, instantaneous operation and optional ground fault operation of the breaker.
Remote Ground Fault Trip Indicator➀For use only with SELTRONIC� Circuit Breakers (LCG, HLCG, MCG, HMCG, NCG, HNCG, PCG and PCCG) with built-in ground fault protection.
SELTRONIC� External Accessories
Style Number: STK2
Further InformationList Prices: See PAD (Price and Availability Digest)
The SELTRONIC� Ground Fault indicator is a remotely mounted device with a combination indicating light/reset/test button that will light when the breaker trips on a Ground Fault. Tripping from overloads or short circuits will not activate the device. A separate 120-50/60 power source is required to power the light and internal relay which has 1 N.O. and 1 N.C. contacts for customer connected alarm etc. Designed for panel mounting, it can be face-mounted by ordering the optional mounting bracket below.
Indicator Catalogue Number: GFAU
Face Mounting Bracket for Ground Fault Indicator
Bracket Style Number: 1264C67G01
� CSA and UL listed as a recognized component.
Replacement AB DE-ION® Circuit Breakers
Portable Test Kit and Remote Ground Fault Trip Indicator
36 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Moulded Case Switches With High Magnetic Trip (Fixed Trip Setting)
SwitchCatalogueNumber➀➁
No. ofPoles
Max.Volts
Max.Amps.
DA2400WKDA3400WK
23
240240
400400
EB1100LKEB2100LKEB3100LKEB3100SLK
1233
120240240240
100100100100
EHB1100LKEHB2100LKEHB3100LKEHB3100SLK
1233
277480480480
100100100100
FB2100LKFB2150LKFB3100LKFB3150LKFB3150SLKFB4100LKFB4150LK
2233344
600600600600600277/480277/480
100150100150150100150
JA2225WKJA2225WSKJA3225WKJA3225WSK
2233
600600600600
225225225225
Moulded Case SwitchesMoulded Case Switches are CSA and Underwriters Laboratories Inc. Iisted devices and are available only as high magnetic trip type with fixed trip setting.
For application information and CSA and UL Iisted withstand ratings, refer to Application Data 29-160, pages 75, 76.
Further Information List Prices: See PAD (Price and Availability Digest)
Moulded Case Switch Terminal Data
MCSType
Max.SwitchAmps.
Standard Terminals Optional TerminalsTerminalType orCat. No.
WireType
No. ofWires Wire Range
TerminalType orCat. No.
WireType
No. ofWires Wire Range
DA, LB, LBB 400 T400DA2 Cu only 2 3/0-250 MCM .
EB, EHB, FBFB
100150
PressurePressure
CuCu/Al
11
#14-1/0#4-4/0
Pressure Cu/Al 1 #4-4/0
JA, KAJB, KB
225250
TA225LA1TA250KB
Cu/AlCu/Al
11
#4-350 MCM#4-350 MCM
T225LAT250KB
CuCu
11
#6-350 MCM#4-350 MCM
CA 225 TA225CA2 Cu/Al 1 #1-300 MCM . . . . . . . . . . . . . . . . . . .
Moulded Case Switches With High Magnetic Trip – Trip Setting and Tolerance
Frame Rating Trip Setting (Amp.) Tolerance (%)EBEHB/FBFB
100100150
100012001500
±20±20±20
DA/LB/LBB
JA/KA
JB/KB
400
225
250
4000
2250
2500
+10– 0+10– 0+10– 0
CA 225 2250 +20-10
� Catalogue number suffix identification:K= Moulded Case Switch with High Magnetic Trip (Fixed Trip Setting)S= Saf-T-Vue� coverL= With Line and Load TerminalsW= No terminals
� Moulded case switch dimensions are the same as the equivalent thermal magnetic breaker. Refer to Dimension Sheet 29-171.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Moulded Case Switches High Magnetic Trip Type (Fixed Trip Setting)
SwitchCatalogueNumber➀➁
No. ofPoles
Max.Volts
Max.Amps.
JB2250WKJB2250WSKJB3250WKJB3250WSK
2233
600600600600
250250250250
KA2225WKKA2225WSKKA3225WKKA3225WSK
2233
600600600600
225225225225
KB2250WKKB2250WSKKB3250WKKB3250WSK
2233
600600600600
250250250250
LB2400WKLB2400WSKLB3400WKLB3400WSK
2233
600600600600
400400400400
LBB2400WKLBB2400WSKLBB3400WKLBB3400WSK
2233
600600600600
400400400400
CA2225KWCA3225KW
23
240240
225225
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 37
494949494949494949494949494949494949494949494949494949494949
SwitchCatalogueNumber➀➁
No. ofPoles
Max.Volts
Max.Amps.
PBF22000WK➄PBF32000WK➄
23
600600
20002000
PC22000WK➃PC22500WK➃ PC23000K ➃PC32000WK ➃PC32500WK ➃PC33000K➃
222333
600600600600600600
200025003000200025003000
PCC22000WK ➃PCC22500WK➃ PCC23000K➃ PCC32000WK➃ PCC32500WK➃ PCC33000K➃
222333
600600600600600600
200025003000200025003000
PCF22000K➃➄PCF32000K➃➄
23
600600
20002000
Moulded Case Switches With High Magnetic Trip (Fixed Trip Setting)
SwitchCatalogueNumber➀➁
No. ofPoles
Max.Volts
Max.Amps.
LA2400WKLA2400WSKLA2600WKLA2600WSK
2222
600600600600
400400600600
LA3400WKLA3400WSKLA3600WKLA3600WSK
3333
600600600600
400400600600
LAB2400WKLAB2400WSKLAB3400WKLAB3400WSK
2233
600600600600
400400400400
LC2600WK➂LC3600WK➂LCC2600WK➂LCC3600WK➂
2323
600600600600
600600600600
Moulded Case Switch Terminal Data
MCSType
Max.SwitchAmps.
Standard Terminals (Aluminum Body) Optional TerminalsTerminalType orCat. No.
WireType
No. ofWires Wire Range
TerminalType orCat. No.
WireType
No. ofWires Wire Range
LA400, LAB 400 TA400LA1 Cu/Al 1 #4-250 MCM, plus3/0-600 MCM
T401LA Cu 1 #4-250 MCM, plus3/0-600 MCM
LA600, LC600 600 TA600LA Cu/Al 2 250/500 MCM T600LA Cu 2 250/500 MCM
MC, MANC, NBNC, NB
80012001200
TA800MA2TA1200NB1
Cu/AlCu/Al
34
3/0-400 MCM4/0-500 MCM
T800MA1T1200NB1TA1201NB1
CuCuCu/Al
343
3/0-300 MCM3/0-400 MCM500-750 MCM
PC2000, PCC2000PC2500, PCC2500PC3000, PCC3000
200025003000
BA2000PB Rear Bus ConnectorBA2500PB Rear Bus ConnectorRear Bus Connector Included in Frame
Moulded Case SwitchesMoulded Case Switches are CSA and Underwriters Laboratories Inc. Iisted devices and are available only as high magnetic trip type with fixed trip setting.
For application information and CSA and UL Iisted withstand ratings, refer to Application Data 29-160, pages 75,76.
Further InformationList Prices: See PAD (Price and Availability Digest)
Moulded Case Switches With High Magnetic Trip – Trip Setting and Tolerance
Frame Rating Trip Setting (Amp.) Tolerance (%)LA (400) 400 4000 +10
– 0
LA/LC 600 6000 +10– 0
MA/MC 800 8000 +10– 0
NB/NC 1200 12000 +10– 0
PB/PC 2000-3000 12000 +10– 0
� Catalogue number suffix identification: K=Moulded Case Switch with High Magnetic Trip (Fixed Trip Setting)S=Saf-T-Vue� coverW=No terminals
� Moulded case switch dimensions are the same as the equivalent thermal magnetic breaker. Refer to Dimension Sheet 29-171.� For moulded case switch types LC, LCC --- use LA attachments; MC and MCC --- use MA attachments; NC --- use NB attachments.� For moulded case switch types PC, PCC and PCF, rating plug is included and use SELTRONIC� PC attachments.� Front connected only.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Moulded Case Switches High Magnetic Trip Type (Fixed Trip Setting) cont’d
SwitchCatalogueNumber➀➁
No. ofPoles
Max.Volts
Max.Amps.
MA2800WKMA2800WSKMA3800WKMA3800WSK
2233
600600600600
800800800800
MC2800WK➂MC3800WK➂MCC2800WK➂MCC3800WK➂
2323
600600600600
800800800800
NB21200WKNB21200WSKNB31200WKNB31200WSK
2233
600600600600
1200120012001200
NC21200WK➂NC31200WK➂
23
600600
12001200
PB22000WKPB22500WKPB32000WKPB32500WK
2233
600600600600
2000250020002500
38 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Motor Circuit Protectors – For Prices, see Price List PL.29.01A.P.K/.F
Starter Size Trip Range, Amps.
Continuous Amp.Rating
With StandardAluminum AlloyTerminals
With OptionalNon-AluminumTerminals➁
Catalogue Numbers0001234455
7-22 18-58 50-150 100-300 160-480 275-1000 450-1550 575-18001250-25002000-4000
3 7 15 30 50100150150250400
MCP0322RMCP0358RMCP03150RMCP13300RMCP23480RMCP331000RMCP431550RMCP431800RMCP532500
MCP0322CRMCP0358CRMCP03150CRMCP13300CRMCP23480CRMCP331000CRMCP431550CRMCP431800CRMCP532500CMCP534000C
Current LimitersLimiter Cat. No. For MCP Cat. No.➂EL3003REL3007REL3015REL3030REL3050REL3100REL3150REL3150R
MCP0322RMCP0358RMCP03150RMCP13300RMCP23480RMCP331000RMCP431550RMCP431800R
Modifications for MCP➃
These modifications must be factory installed.
DescriptionAuxiliary Switches➄ 1A and 1B, 2As and 2BsShunt Trip➄Undervoltage Release➄➅➆Moisture-Fungus Treatment
Motor Circuit ProtectorThe MCP is designed specifically for the protection of motor circuits. It operates on the magnetic principle with a current sensing coil in each of the 3 poles, with the trip-point adjustable from the front. MCPs are the fastest devices available for clearing low level faults and offer circuit breaker features and convenience, resettable, quick make-quick break, dead front, and protection againstsingle phasing.
MCPs are rated to correspond to NEMA starter sizes.
Current Limiter Attach. (Size 0-4 Only)The EL current limiter is an attachment that bolts to the load end of the MCP to provide increased interrupting capacity. The combination is CSA and UL Listed as a recognized component for application at up to 200,000 Amps symmetrical at 600 volts AC. It is coordinated with the MCP so that normal short circuits will be cleared automatically by the MCP, opening all 3 poles, and only the rare high fault will cause the limiter to function. Current limiters must be applied as shown in the table below.
TerminalsTerminals are included with both the MCP and Current Limiter. Standard terminals are aluminum alloy, with non-aluminum terminals optional for use with only the MCP. Both standard and optional terminals will accommodate aluminum or copper conductors.➀ When using aluminum conductors, use of joint compound is recommended. Wire ranges are listed below.
CSA and UL ListedThe MCP is listed with CSA and Underwriters Laboratories Inc. as a recognized component and requires additional listing by the control manufacturer in combination with a contactor and overload relay.
MCP orLimiter
TerminalsStandardAlum.
OptionalNon-Alum.
Size 0, 1, 2Size 3Size 4Size 5 (250 Amp.)Size 5 (400 Amp.)Limiters to 50 Amps.Limiters to 100 Amps.Limiters to 150 Amps.
#14-#4#6-3/0#4-4/0#4-350MCM
#14-#2#1-4/0#1-4/0
#14-1/0#14-1/0#4-4/0#4-350MCM(2)-3/0-250MCM
Size 0-4 MCP With Current Limiter
Size 5 MCP 532500
Accessories for MCP➃
For accessories such as motor operators, terminal shields, handle locks, handle mechanisms and rear studs, refer to pages 39 - 49 and Technical Data 29-520 and select as follows:
For MCP Size Use Access. For0-45 (250 Amp.)5 (400 Amp.)
FBKBLB
� Except 400 Amp size 5. Non-aluminum terminal suitable for copper only.� Catalogue numbers ending in CR were previously listed ending in RC. This is a catalogue number change only, not a material change.� Also applicable to MCPs with optional terminals.� Not CSA and UL listed.� Mounts only in right pole; only one Modification marked➄ can be used in MCP. (Size 0-4)� On 400 Amp size 5, an external resistor is supplied for voltages above 240 volts AC and 24 volts DC.� On size 0-4 and 250 Amp size 5, an external resistor is supplied for customer mounting, except for 120 volts AC, 12, 24, 125 volts DC.
Interrupting RatingsMaximum application current shall be determined by testing the MCP in combination with a contactor and overload relay. Additional capacity can be obtained by using the current limiter attachment.
Base Mounting HardwareOrder separately when required.Size 0-4, Style No. 21C6782G18Size 5 (250 Amp.), Style No. 673B125G12Size 5 (400 Amp.), Style No. 21C6782G22
Further InformationList Prices: Price List 25-000
Application: Application Data 29-160
Characteristic Curves: Application Data29-360-A
Dimensions: Dimension Sheet 29-171
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Motor Circuit Protectors
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 39
494949494949494949494949494949494949494949494949494949494949
Replacement AB DE-ION® Circuit Breakers
Accessories
Rear Connected Studs➀For complete stud assembly, order a stud and appropriate tube based on thickness of customer’s mounting panel. A short stud must be assembled adjacent to a long stud to maintain clearances required by CSA and UL➁ . Two studs are required per pole. Refer to DS 29-170 for stud sizes and extensions behind breaker.
� Not CSA and UL listed.� 400 ampere LA studs of the same length have sufficient clearance; however, customer connections may make it necessary to use a
short stud adjacent to a long stud.� 150, 250, 300 and 400 amp frames only.� This is a special stud which includes six contact nuts for use where bus contact nuts must be used.� 600 ampere frames only.
For LAB, LA, MA, HLA, HMA, and HNB BreakersFor insulated panels only; 2 required per pole.
StudAmpereRating
Diameter, Inches and Thread
Extension Back of Breaker, Inches
StudStyleNumber
LAB, LA, HLA, LC, HLC Breakers
225➂ 225➂ 225➂➃ 400➂ 400➂ 400➂ 600➄ 600➄ 600➄
1⁄2-131⁄2-131⁄2-133⁄4-163⁄4-163⁄4-161 -121 -121 -12
37⁄32
69⁄32
431⁄32
515⁄32
731⁄32
1015⁄32
529⁄32
813⁄32
1029⁄32
1241 3451241 3461241 3925B7383G155B7383G165B7383G17314C960G07314C960G08314C960G09
MA, HMA, MC, HMC Breakers
225 400 400 400 600 600 600 800 800 800
1⁄2-133⁄4-163⁄4-163⁄4-161 -121 -121 -1211⁄8-1211⁄8-1211⁄8-12
321⁄32
529⁄32
813⁄32
1029⁄32
529⁄32
813⁄32
1029⁄32
529⁄32
813⁄32
1029⁄32
314C960G01314C960G04314C960G05314C960G06314C960G07314C960G08314C960G09314C960G10314C960G11314C960G12
NB, HNB, NC, HNC Breakers
800 800 80012001200
11⁄8-1211⁄8-1211⁄8-1211⁄4-1211⁄4-12
51⁄2 8101⁄2 51⁄2101⁄2
623B222G01623B222G02623B222G03373B375G04373B375G03
For DA, EB, EHB, FB, JA, KA, JB, KB, LB, LBB, HFB, HKA, HKB, HLB Breakers For insulated panels only; 2 required per pole.
MountingPanelThickness,Inches
Stud Tube
LengthStyleNumber Length
StyleNumber
DA, LB, LBB, HLB Breakers
3⁄4 - 1
1⁄2 - 3⁄4
1⁄4 - 1⁄2
ShortLongShortLongShortLong
656D565G03656D565G04656D565G03656D565G04656D565G03656D565G04
27⁄32
325⁄32
13⁄32
41⁄32
111⁄32
49⁄32
313C909H17313C909H20313C909H18313C909H21313C909H19313C909H22
EB, EHB, FB, HFB (100 Amp Max.)
1
11⁄16- 15⁄16
3⁄8 - 5⁄8
1⁄4 - 5⁄16
ShortLongShortLongShortLongShortLong
451D874G01451D874G02451D874G01451D874G02451D874G01451D874G02451D874G01451D874G02
11⁄16
37⁄16
13⁄833⁄4111⁄16
41⁄16
243⁄8
32B9446H2032B9446H2432B9446H2132B9446H2532B9446H2232B9446H2632B9446H2332B9446H27
FB, HFB 150 Amp Breakers
1
11⁄16- 15⁄16
3⁄8 - 5⁄8
1⁄4 - 5⁄16
ShortLongShortLongShortLongShortLong
374D883G01374D883G02374D883G01374D883G02374D883G01374D883G02374D883G01374D883G02
11⁄16
45⁄16
13⁄845⁄8111⁄16
415⁄16
251⁄4
374D883H06374D883H10374D883H07374D883H11374D883H08374D883H12374D883H09374D883H13
JA, KA, HKA Breakers
3⁄4 - 1
1⁄2 - 3⁄4
1⁄4 - 1⁄2
ShortLongShortLongShortLong
656D565G01656D565G02656D565G01656D565G02656D565G01656D565G02
27⁄32
325⁄32
13⁄32
41⁄32
111⁄32
49⁄32
456D983H05456D983H08456D983H06456D983H09456D983H07456D983H10
JB, KB, HKB Breakers
3⁄4 - 1
1⁄2 - 3⁄4
1⁄4 - 1⁄2
ShortLongShortLongShortLong
5010D23G015010D23G025010D23G015010D23G025010D23G015010D23G02
27⁄32
37⁄813⁄32
41⁄8111⁄32
43⁄8
456D983H055010D23H05456D983H065010D23H06456D983H075010D23H07
40 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Replacement AB DE-ION® Circuit Breakers
Accessories
Panelboard Connecting Straps➀For connecting line end of breakers to panelboard bus.
For LAB, LA, MA, HLA, HMA, and HNB Breakers
AmpereRating
ConnectorType
StyleNumber
CA Breaker Power Panelboards (Convertible)Bus Spacing 31⁄2 in.
225 225
centreOutside
1253C74G011253C74G02
3-Pole Mounting Bracket2-Pole Mounting Bracket
624B624H01624B624H02
LAB, LA, HLA, LC, HLC 150, 300, 400 Amp FramesBus Spacing 31⁄2 in.
400 400
centreOutside
32B4570G02314C541G01
Mtg. Bracket (2 Required) 208B297H01
LA, HLA, LC, HLC 600 Amp FramesBus Spacing 31⁄2 in.
600 600
centreOutside
624B609G01506C052G01
Mtg. Bracket (2 Required) 208B297H01
MA, HMA, MC, HMC BreakersBus Spacing 31⁄2 in.
800 800 800
ShortMediumLong
314C996G01314C996G02314C996G03
Mtg. Bracket (4 Required) 315C270H01
NB, HNB, NC, HNC BreakersBus Spacing 31⁄2 in.
120012001200
ShortMediumLong
505C606G04505C606G05505C606G06
Mtg. Bracket (4 Required) 315C270H01
For DA, EB, EHB, FB, JA, KA, JB, KB, LB, LBB, HFB, HKB, and HLB Breakers
AmpereRating
ConnectorType
StyleNumber
EB, EHB, FB, HFB BreakersNarrow Distribution PanelboardsBus Spacing 23⁄4 in. in Box 53⁄4 in. Deep (600 Volts Max.)
50 50100100150150
centreOutsidecentreOutsidecentreOutside
673B142G02673B142G09673B142G02673B142G10673B142G04673B142G03
Power Panelboards (Convertible)Bus Spacing 31⁄2 in.
50 50100100150150
centreOutsidecentreOutsidecentreOutside
1253C72G011253C72G031253C73G031253C73G061253C73G011253C73G05
3-Pole Mounting Bracket2-Pole Mounting Bracket
624B600H01624B600H02
DA, LB, LBB, HLB BreakersBus Spacing 31⁄2 in.
400400
centreOutside
314C940G04505C680G01
Mtg. Bracket (1 Required) 208B264H01
JA, KA, HKA BreakersBus Spacing 31⁄2 in.
225225
centreOutside
314C940G03180C074G01
Mtg. Bracket (1 Required) 208B264H01
JB, KB, HKB BreakersBus Spacing 31⁄2 in.
250250
centreOutside
2600D26G012600D26G02
Mtg. Bracket (1 Required) 1576707
� Not CSA and UL listed.
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 41
494949494949494949494949494949494949494949494949494949494949
Replacement AB DE-ION® Circuit Breakers
Accessories
Plug-in Adapter Kits
For rear connected applications such as switchboards. Facilitates ease of installation and front removal of breaker. Includes conductor for mounting on breaker, plug-in mounting blocks with matching conductor, rear studs and mounting hardware. Order 2 mounting blocks style number when line and load are required; order 1 mounting block style number when either line or load is required.
DescriptionStyleNumber
MA, HMA, MC, HMC Breakers➁ Flat Bus Type
2 Mounting Blocks, Line and Load
2-Pole, 125-600 Ampere2-Pole, 700-800 Ampere3-Pole, 125-600 Ampere3-Pole, 700-800 Ampere
313C644G27176C544G01➁313C644G28176C544G02➁
1 Mounting Block, Line or Load
2-Pole, 125-600 Ampere2-Pole, 700-800 Ampere3-Pole, 125-600 Ampere3-Pole, 700-800 Ampere
313C370G03507C049G01➁313C370G04507C049G02➁
MA, HMA, MC, HMC, NB, HNB, NC, HNC, NB TRI-PAC Breakers➂ (Threaded Studs)
1 Mounting Block, Line or Load
MA, HMA, MC, HMC 2-PolesMA, HMA, MC, HMC 3-PolesNB, HNB, NC, HNC, NB TRI-PAC,2-PolesNB, HNB, NC, HNC, NB TRI-PAC,3-Poles
2614D53G052614D53G06
2614D53G03
2614D53G04
NB, HNB, NC, HNC Breakers Flat Bus Type1 Mounting Block, Line or Load
2-Pole3-Pole
4990D16G024990D16G01
Threaded Studs Type
DescriptionStyleNumber
LAB, LA, HLA, LC, HLC (150, 250, 300 and 400 Amp Frame)➀ (Threaded Studs)
2 Mounting Blocks, Line and Load
2-Pole3-Pole
313C644G25313C644G26
1 Mounting Block, Line or Load
2-Pole3-Pole
450D010G15450D010G16
LA, HLA, LC, HLC (600 Ampere Frames)➀(Threaded Studs)
2 Mounting Blocks, Line and Load
2-Pole3-Pole
313C644G50313C644G51
1 Mounting Block, Line or Load
2-Pole3-Pole
506C059G01506C059G02
1 Mounting Block, Line or Load Flat Bus Type
2-Pole3-Pole
1288C19G011288C19G01
Mounting Plates
Pre-drilled Panels for:EB, EHB, FB, HFBJB, KBJA, KADA, LB, LBB, ALBLA, LAB, HLA, LC, HLCMA, HMA, MC, MMC, NB, HNB,NC, HNC
507C047H01179C207H01504C823H01178C781H01504C824H01
1290C73H01
DescriptionStyleNumber
DA, LB, LBB, HLB Breakers➀ Flat Bus Type
2 Mounting Blocks, Line and Load
2-Pole3-Pole
313C644G45313C644G46
1 Mounting Block, Line or Load
2-Pole3-Pole
314C932G03314C932G04
EB, EHB, FB Thermal Magnetic Breakers➀ Flat Bus Type
1 Mounting Block, Line or Load
2-Pole, 100 Ampere2-Pole, 150 Ampere3-Pole, 100 Ampere3-Pole, 150 Ampere
1480D13G051480D13G051480D13G061480D13G06
FB and HFB Magnetic Only, HFB Thermal Magnetic➀ Flat Bus Type
1 Mounting Block, Line or Load
2-Pole, 100 Ampere2-Pole, 150 Ampere3-Pole, 100 Ampere3-Pole, 150 Ampere
1480D13G051480D13G051480D13G061480D13G06
JA, KA, HKA Breakers➂ (Threaded Studs)
2 Mounting Blocks, Line and Load
2-Pole3-Pole
313C644G29313C644G30
1 Mounting Block, Line or Load
2-Pole3-Pole
314C932G01314C932G02
JB, KB, HKB Breakers➀ Flat Bus Type
2 Mounting Blocks, Line and Load
2-Pole3-Pole
506C144G17506C144G18
1 Mounting Block, Line Only
2-Pole3-Pole
1260C86G011260C86G02
1 Mounting Block, Line Only
2-Pole3-Pole
1260C86G031260C86G04
Flat Bus Type
� These plug-in adapter kits are CSA and UL listed as recognized components.� 700-1200 amp adapter kit is front removable, bolt-on design — not plug-in type.� Not CSA and UL listed.
42 Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Extended Line Terminal Shields
➀
For shielding line side terminal connections. One shield required per breaker. Order separately when needed. Sold in lots of 10 (except as noted), including hardware.
BreakerFrame
StyleNumber
JB, KB, HKBDAJA, KA, LB, LBB (Saf-T-Vue
�
)JA, KA, HKA, LB, LBB, HLB (Standard Breaker)LAB, LA, HLA, LC, HLCLAB, LA, (Saf-T-Vue
�
)MA, HMA, MC, HMCNB, HNB, NC, HNCEB, EHB, FB, HFB
1266C07G01314C420G06314C420G04
➁
314C420G06314C420G05
➁
314C420G02
➁
208B966G01
➁
208B966G02625B229G08
Base Mounting Hardware
Order separately when needed.
DescriptionStyleNumber
1-Pole Breakers
EB, EHB, HFB
➂
EB, EHB, HFB
➃
624B375G01624B375G02
2- and 3-Pole Breakers
LAB, LA, HLA, LC, HLCMA, NB, HMA, HNB, MC, HMC, NC, HNCPB, PC, PCCDA, JA, KA, HKA, LB, LBB, HLBEB, EHB, FB, HFB, MCPJB, KB, HKB
21C6782G05
1091 716624B375G2221C6782G2221C6782G18673B125G12
CA 2-PoleCA 3-Pole
21C6782G2821C6782G29
Handle Locks
➀
Non-Padlockable
For prevention of unintentional operation of breaker. Fits over breaker handle and may be removed.
Padlockable
For prevention of unauthorized operation of breaker. Is non-removable once installed on breaker. Meets CSA and Underwriters Laboratories Inc. and California Code requirements.
Note:
All breakers are trip free and will trip with handle locks attached. Cannot be used when handle extension is used.
BreakerFrame
StyleNumber
Non-Padlockable
CA, EB, EHB, FB, HFBLAB, LA, LC, HLC, MA, NB, HLA, HMA, HNB, MC, HMC, NC, HNCGB, GC, GHB, GHCDA, JA, KA, HKA, LB, LBB, HLB
29B2721H01
28B4596G011294C01H01
4212B80G01
Padlockable
CAEB, EHB, FB, HFBDA, JA, KA, LB, LBB, HKA, HLBJB, KB, HKBLAB, LA, HLA, LC, HLCMA, HMA, MC, HMCMA, HMA, MC, HMCNB, HNB, NC, HNCNB, HNB, NC, HNCPB, PC
506C438G01765A754G01
673B796G02673B796G01373B591G026591C30G02 – OFF6591C30G05 – ON/OFF6591C30G01 – OFF6591C30G04 – ON/OFF6591C30G03 – OFF
Moulded Type Handle Extension
➀
For LAB, LA, HLA Breakers
Style Number 372B399G01.
For MA, HMA, MC, HMC Breakers
Style Number 1251C65G01.
For NB, HNB, NC, and HNC Breakers
Style Number 1251C65G01.
➄
For PB, PC, and PCC Breakers
Style Number HEX6.
➄
�
Not CSA and Underwriters Laboratories Inc. listed.
�
Sold in quantities of 1.
�
Individually mounted.
�
Group mounted.
�
Included with frame at no charge.
�
Interrupters used with fuse mounting base will accept all standard PB accessories. See DS 29-171 for mounting details.
Fuse Mounting Base for PB Breakers
➀➅
For 2000 amp non-automatic breakers only.
Catalogue Number: FMB2000PB
For use with non-automatic, 3-pole circuit breaker. Includes fuse mounting base and hardware to mount standard class L current limiting fuses, 801 to 2000 amps (fuses not included).
➅
For complete installation, order:
1. Front connected, non-automatic PB breaker. (Order similar to standard front connected, except omit load conductor extensions)
2. Fuse mounting base.
3. Fuses (from distributor).
Cable Connectors
The fuse mounting base will accept the following terminals for front cable connection (omit “T” connectors from rear connected breakers).
StyleNumber
Wire Range, Type No. Of Cables
672B655G01180C046G03
3 3/0-400 MCM Cu4 400-500 MCM Cu
Replacement AB DE-ION® Circuit Breakers
Accessories
Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
43
494949494949494949494949494949494949494949494949494949494949
Modifications
Only two internally mounted modifications — shunt trip, undervoltage release, auxiliary switch, alarm switch — may be mounted in EB through PB. Only one of these modifications may be mounted in FB, HFB magnetic only, 2 pole EB, EHB, FB and SELTRONIC
�
breakers. None are available in 1-pole breakers except alarm switch in EB, EHB and HFB. Refer to Eaton for possible special combinations of the following modifications not in tabulations.
Shunt Trip
For tripping breaker from a remote point. A solenoid device mounts within breaker case. Breaker trips when coil is energized.
Shunt trips should not be used as circuit interlocks using maintained contact pilot devices.
A cut-off switch breaks the circuit to the momentary rated coil when breaker opens. Available for control voltages up to 250 volts DC or 600 volts AC. Voltage and frequency must be specified. Standard leads extend 18 inches outside the breaker. Longer leads may be specified.
Shunt Trip for Field Mounting
➀➁➂
Voltage/Hertz
Breaker TypeEB, EHB, FB, HFB
➃
(Thermal Magnetic only) JB, KB, HKBJA, KA, HKA, DA, LB, LBB, HLB LA, LAB, HLA MA, HMA NB, HNB PB
Right Hand Mounting
600/50-60 Hz480/50-60 Hz240/50-60 Hz208/50-60 Hz120/50-60 Hz 60/50-60 Hz 48/50-60 Hz 24/50-60 Hz250 DC125 DC 60 DC 48 DC 24 DC 12 DC
2609D39G152609D39G162609D39G172609D39G182609D39G192609D39G202609D39G212609D39G222609D39G232609D39G242609D39G252609D39G262609D39G272609D39G28
2609D42G152609D42G162609D42G172609D42G182609D42G192609D42G202609D42G212609D42G222609D42G232609D42G242609D42G252609D42G262609D42G272609D42G28
2605D15G152605D15G162605D15G172605D15G182605D15G192605D15G202605D15G212605D15G222605D15G232605D15G242605D15G252605D15G262605D15G272605D15G28
2606D56G152606D56G162606D56G172606D56G182606D56G192606D56G202606D56G212606D56G222606D56G232606D56G242606D56G252606D56G262606D56G272606D56G28
2606D57G152606D57G162606D57G172606D57G182606D57G192606D57G202606D57G212606D57G222606D57G232606D57G242606D57G252606D57G262606D57G272606D57G28
2606D58G152606D58G162606D58G172606D58G182606D58G192606D58G202606D58G212606D58G222606D58G232606D58G242606D58G252606D58G262606D58G272606D58G28
2606D59G152606D59G162606D59G172606D59G182606D59G192606D59G202606D59G212606D59G222606D59G232606D59G242606D59G252606D59G262606D59G272606D59G28
Left Hand Mounting
600/50-60 Hz480/50-60 Hz240/50-60 Hz208/50-60 Hz120/50-60 Hz 60/50-60 Hz 48/50-60 Hz 24/50-60 Hz250 DC125 DC 60 DC 48 DC 24 DC 12 DC
2609D39G012609D39G022609D39G032609D39G042609D39G052609D39G062609D39G072609D39G082609D39G092609D39G102609D39G112609D39G122609D39G132609D39G14
2609D42G012609D42G022609D42G032609D42G042609D42G052609D42G062609D42G072609D42G082609D42G092609D42G102609D42G112609D42G122609D42G132609D42G14
2605D15G012605D15G022605D15G032605D15G042605D15G052605D15G062605D15G072605D15G082605D15G092605D15G102605D15G112605D15G122605D15G132605D15G14
2606D56G012606D56G022606D56G032606D56G042606D56G052606D56G062606D56G072606D56G082606D56G092606D56G102606D56G112606D56G122606D56G132606D56G14
2606D57G012606D57G022606D57G032606D57G042606D57G052606D57G062606D57G072606D57G082606D57G092606D57G102606D57G112606D57G122606D57G132606D57G14
2606D58G012606D58G022606D58G032606D58G042606D58G052606D58G062606D58G072606D58G082606D58G092606D58G102606D58G112606D58G122606D58G132606D58G14
2606D59G012606D59G022606D59G032606D59G042606D59G052606D59G062606D59G072606D59G082606D59G092606D59G102606D59G112606D59G122606D59G132606D59G14
Factory Mounted Shunt Trips
➀➄
All of the above shunt trips can be specified for factory mounting at the same price as listed for the kit. These shunt trips have the leads out the side and are CSA and UL listed when factory mounted, unless other non-CSA and UL listed modifications are used.
Factory mounted shunt trips only can be supplied for the following breakers:
FB magnetic only
➅
, HFB magnetic only
➅➆
and non-automatic breakers (moulded case switches)
➁
.
�
120 volt AC ratings suitable for 55% pickup for ground fault applications.
�
Not field mountable on non-automatic breakers (moulded case switches).
�
Field mounting voids breakers’ CSA and UL listing except on LA, HLA, MA, HMA, NB, HNB, KB, HKB, KA, HKA, LB, HLB and SELTRONIC
�
breakers.
�
Available similar to this except “Leads out the load end – (not CSA and UL listed)”. Order by description.
�
Right hand mounting considered standard unless specified otherwise.
�
Not CSA and UL listed.
�
Right hand mounting only.
Replacement AB DE-ION® Circuit Breakers
Accessories
44 Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Left Hand Mounting Kits for Seltronic
�
Breakers
Provision to trip flux transfer shunt trip from external32 to 120 volt (DC to 60 Hz) source.
➀➁
Provision to trip flux transfer shunt trip from external240 to 600 volt AC, 50/60 Hz source.
➁➂
MC, HMCStyle 1371D72G22NC, HNCStyle 1372D39G13PC, PCCStyle 1372D35G22LC, HLCStyle 1371D11G22
MC, HMCStyle 1371D72G32NC, HNCStyle 1372D39G23PC, PCCStyle 1372D35G32LC, HLCStyle 1371D11G32
�
Rated 48 volts minimum for ground fault applications.
�
Also available factory mounted for 24 volts DC. Order by description.
�
Not for ground fault.
Replacement AB DE-ION® Circuit Breakers
Accessories
Shunt Trip Coil Data
Shunt TripVoltage Rating
For All Breakers Listed Above and onPrevious Page Except CA and SELTRONIC
�
SELTRONIC
�
Coil Inrush Coil InrushAmperes Volt-Amperes Amperes Volt-Amperes
600 AC480 AC240 AC208 AC120 AC 60 AC 48 AC 24 AC250 DC125 DC 60 DC 48 DC 24 DC (FCL) 24 DC (others) 12 DC
0.1050.0851.71.40.889.107.503.952.50.9750.5251.36.08.6.
63.0 40.8408.0291.2105.6546.0360.0 94.8625.0121.9 31.5 62.4144.0192. 72.
————.15——————————
————18——————————
Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
45
494949494949494949494949494949494949494949494949494949494949
Standard Undervoltage Release
For undervoltatge protection. A solenoid device mounts within breaker case. Coil must be energized before closing breaker. Trips breaker when voltage drops below 35 to 70% of coil rating. Picks up and seals in at 85% of coil rating. For line voltages up to 250 volts DC or 600 volts AC. Externally mounted resistors are supplied for certain ratings. Standard leads extend 18 inches outside of breaker. Longer leads may be specified.
Note:
U.V.R. attachments are not designed for, and should not be used as, circuit interlocks. For further information, refer to Eaton.
Factory Mounted Undervoltage Releases
➀
All of the above undervoltage releases can be specified for factory mounting at the same price as listed for the kit. These attachments have the leads out the side and are CSA and UL listed when factory mounted unless other non-CSA and UL listed modifications are used.
Factory mounted undervoltage releases only can be supplied for the following breakers:
SELTRONIC
�
Breakers (120V AC 60 Hz only standard), MC, HMC
➁
, NC, HNC
➁
, PC, PCC, LC, HLC
SELTRONIC
�
Breakers with Remote Trip Provisions, MC, HMC
➁➂
, NC, HNC
➁➂
, PC, PCC
➂
, LC, HLC
➂
.
EB
➃
, EHB
➃
, FB
➃
, HFB
➃
, FB
➄➅
and HFB magnetic only
➄➅
, JB, KB, HKB
�
Right hand mounting considered standard unless specified otherwise except JA, KA, DA, HKA, LB, LBB, HLB and SELTRONIC
�
available for lefthand only, and JB, KB, HKB left hand is standard.
�
Cannot be used with other attachments except a small 1A-1B auxiliary switch rated 250 volts can be supplied in right hand pole.
�
Provided with two leads (total of 4) for use with a remote normally open contact (pushbutton etc.) to trip the breaker. No external power required.
�
Not available on ambient compensating breakers.
�
Not CSA and UL listed.
�
Right hand mounting only.
�
Not field mountable on non automatic breakers. (Moulded case switches)
Field mounting voids CSA and UL listing of breaker except on LA, HLA, MA, HMA, NB, HNB, PB, KA, HKA, LB, HLB.
Undervoltage Release Attachment Kits for Field Mounting
➆➇
AttachmentVoltage, Hertz
Breaker TypeJA, KA, DA, HKA, LB, LBB, HLB LA, LAB, HLA MA, HMA NB, HNB PB
For Right Hand Mounting
24 60 48 60120 60208 60240 60480 60600 60 12 DC 24 DC 48 DC 60 DC125 DC250 DC
—————————————
60A9355G1760A9355G0860A9355G0160A9355G0260A9355G0360A9355G0560A9355G06458D020G01458D020G02458D020G03458D020G04458D020G07458D020G08
——457D727G01457D727G19457D727G02457D727G03457D727G04457D727G09457D727G10457D727G11457D727G21457D727G12457D727G13
——373D632G01373D632G19373D632G02373D632G03373D632G04372D032G01372D032G02372D032G03—372D032G04372D032G05
—5674D29G165674D29G095674D29G105674D29G115674D29G135674D29G144976D85G014976D85G024976D85G034976D85G044976D85G074976D85G08
For Left Hand Mounting
48 60120 60208 60240 60480 60600 60 12 DC 24 DC 48 DC 60 DC125 DC250 DC
—458D070G01458D070G05458D070G02458D070G03458D070G04458D070G09458D070G10458D070G11—458D070G12458D070G13
60A9355G1660A9355G0960A9355G1060A9355G1160A9355G1360A9355G14458D020G11458D020G12458D020G13458D020G14458D020G17458D020G18
—457D727G05457D727G20457D727G06457D727G07457D727G08457D727G14457D727G15457D727G16457D727G22457D727G17457D727G18
—373D632G05373D632G20373D632G06373D632G07373D632G08372D032G06372D032G07372D032G08—372D032G09372D032G10
5674D29G085674D29G015674D29G025674D29G035674D29G055674D29G064976D85G114976D85G124976D85G134976D85G144976D85G174976D85G18
Undervoltage Release Coil Data
VoltageRatingHertz
Breaker TypeEB, EHB, FB, HFB, JB, KB and HKB JA, KA, HKA, DA, LB, LBB, HLB LA, LAB, HLA, PB
Coil Amperes
External SeriesResistance (Ohms)
TotalVA
Coil Amperes
External SeriesResistance (Ohms)
TotalVA
Coil Amperes
External SeriesResistance (Ohms)
TotalVA
600 AC480 AC240 AC208 AC120 AC 60 AC 48 AC 24 AC250 DC125 DC 60 DC 48 DC 24 DC 12 DC
0.0200.0160.0210.0190.0230.2030.2450.2500.0260.0260.2480.2600.1410.286
25,00020,000 6,000 6,000— 250 150 50 5,000— 200 150——
12.0 7.7 5.1 4.0 2.812.211.8 6.0 6.5 3.314.912.5 3.4 3.5
0.0120.0130.0130.0180.023———0.0130.0130.0130.0120.0230.048
50,00030,000——————16,500 6,500 1,500 600——
7.2 6.3 3.2 3.8 2.8——— 3.3 1.7 0.8 0.6 0.6 0.6
0.0290.0140.0360.0360.073—0.152—0.0350.0390.0340.0400.0690.136
20,000——————— 5,000 1,500————
17.4 6.8 8.7 7.5 8.8— 7.3— 8.8 4.9 2.1 2.0 1.7 1.7
Breaker Type
MA and HMA NB and HNBMC, HMC, NC, HNC, PC, PCC, LC, HLC
600 AC480 AC240 AC208 AC120 AC 60 AC 48 AC 24 AC250 DC125 DC 60 DC 48 DC 24 DC 12 DC
0.0120.0130.0130.0180.023———0.0130.0130.0130.0120.0230.048
50,00030,000——————16,500 6,500 1,500 600——
7.26.33.23.82.8———3.31.70.80.60.60.6
0.0160.0130.0130.0180.023———0.0130.013—0.0120.0230.048
35,00030,000——————16,500 6,500— 600——
9.66.33.23.82.8———3.31.7—0.60.60.6
————0.5—————————
——————————————
————6—————————
Replacement AB DE-ION® Circuit Breakers
Accessories
46 Replacement AB DE-ION® Circuit Breakers
PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Alarm Switch
Availability:
EB through PC. For light or alarm indication when breaker trips. Does not function with manual operation. Automatically resets when breaker is relatched. Standard leads extend 18 inches outside of breaker. Longer leads may be specified. Not field mountable.
Alarm Switch Contact Rating (Non Inductive)
MC, HMC, LA, LAB, HLA, LC, HLC:10 amps, 120 volt AC; 5A, 240 volt AC.
EB, EHB, FB, HFB:5 amp, 120 volt AC.
All other breakers:10 amps, 120-240 volt AC.
BreakerFrame
NormalPole Mtg.
Contact Operation(Specify TypeDesired)
DAEB, EHB, FB, HFB
➀➁
JA, KA, LB LBB, HKA, HLBJB, KB, HKBLAB, LA, MA, NB, HLA, HMA, HNB,PBMC, HMC,NC, HNCPC, PCCLC, HLC
Left
Mechanism
LeftLeft
LeftLeftLeft only
➂
Left only
➂
Left
➂➃
Left
➂
Make or Break
Make or Break
Make or BreakMake or Break
Make or BreakMake or BreakMake or BreakMake or BreakMake or BreakMake or Break
Auxiliary Switch
➄
For auxiliary control circuits. Miniature switches mount within breaker. Commonly used for remote indication of open or closed breaker and electrically interlocking component control circuits. “A” contacts are closed when breaker is closed. “B” contacts are open when breaker is closed. Standard leads extend 18 inches outside of breaker. Longer leads may be specified.
Auxiliary Switch Attachment Kits for Field Mounting
➅➆➇
BreakerType
For Left Hand Mounting For Right Hand Mounting Max ACVoltageRating
➈
Max Non-inductiveAmps1A-1B 2A-2B 1A-1B 2A-2B
EB, EHB, FB, HFB
➉
JA, KA, DA, HKA, LB, LBB, HLBJB, KB, HKBJB, KB, HKBLA, LAB, HLAMA, HMANB, HNB,PBMC, HMC, MCG, HMCGNC, HNC, NCG, HNCGPC, PCC, PCG, PCCGLC, HLC, LCG, HLCG
4979D06G03458D067G03—2600D97G03—655D555G12458D013G124980D16G122602D32G111371D72G031372D39G031372D35G031371D11G03
4979D06G09—656D527G01
➀
—2609D45G03
➀
6555D55G134580D13G134980D16G132602D32G121371D72G061372D39G061372D35G061371D11G06
4979D06G03458D067G08—2600D97G08—655D555G05458D013G054980D16G052602D32G14————
4979D06G08—656D527G09
➀
—2609D45G08
➀
655D555G06458D013G064980D16G062602D32G15————
240480240480240480480480480480480480480
510 510 510101010 6 (10 @ 240) 6 (10 @ 240) 6 (10 @ 240) 6 (10 @ 240)
Factory Mounted Auxiliary Switches
➄
All of the above auxiliary switches can be specified for factory mounting at the same price as listed for the kit. These attachments have the leads out the side of the breaker and are CSA and UL listed when factory mounted unless other non CSA and UL listed modifications are used (except as noted).
Factory mounted switches only can be supplied for the following breaker:
JB, LBB, LAB, JA, DA, FB magnetic only
➀
�
and HFB magnetic only
➀
�
.
Black Lead
Blue Lead
Red Lead
Replacement AB DE-ION® Circuit Breakers
Accessories
�
Not CSA and UL listed.
�
Not available for magnetic only, ambient compensating, or breakers with undervoltage release.
�
When alarm switch is used in conjunction with auxiliary switch, the auxiliary switch is rated 250 volts max, 5 amps max.
�
Except when other attachments are used, must be mounted in right pole.
�
Right hand mounting standard for EB, EHB, FB, HFB, JB, KB, HKB. All others are lefthand mounting as standard unless otherwise specified.
� Not for use on moulded case switches.� All switches are multiples of 1A-1B with a common electrical connection (see diagram below). Field mounting voids CSA and UL listing of breaker except on LA, HLA, MA, HMA, NB, HNB, KB, HKB, KA, HKA, LB, HLB and SELTRONIC� breakers. For DC applications, refer to Eaton.� Thermal magnetic only.� Right hand mounting only.
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 47
494949494949494949494949494949494949494949494949494949494949
Availability: 600 Amp Frames (LA) through 1200 Amp Frames except SELTRONIC� and current limiting breakers.
Provides connections for dual voltage generators, so that same trip unit can be used for protection at both voltages. At higher voltage, the trip unit carries full load current. At lower voltage, half the current by-passes the trip unit through the centre studs. Trip rating cannot exceed 50% of frame rating.
Field Discharge Switch Availability: 400 Amp Frame (LA).
Breaker is used exclusively to discharge the field of a DC motor or generator, usually through a resistor. When the two outer poles open, the centre pole closes.
Moisture-Fungus-Corrosion Treatment➀Availability: EB through PC Treatment can be provided to meet customer's specific atmospheric conditions. Moisture-fungus treating material used meets JAN-T-152; treatment meets MIL-V-173a. Requests and orders should specify government specifications or conditions to be met.
Mechanical Interlocks➀For mechanically interlocking a pair of breakers so that only one may be closed at one time, but both may be open simultaneously.
Walking Beam Type➀➁➂
Availability: EB through PC
Permits interlocking of two breakers or one breaker with other devices. Before breaker can be closed, key must be inserted and turned in breaker interlock. Breaker must be opened before key can be removed. It can then be inserted in interlock or other devices to permit their closure. Requests and orders should completely outline interlocking scheme, ultimate user and his address.
Availability: EB through PC
Mounts on panel (not included) at rear of breaker. Standard breaker spacing: centre to centre; LAB, LA, LC, HLC, MA, MC, NB, NC, HLA, HMA, HMC, HNB, HNC 8-1/2 inch centre to centre; PB, PC, PCC; 12-1/4 inch centre to centre; DA, JA, KA, HKA, LB, LBB, HLB 5-3/4 inch centre to centre; EB, EHB, FB, JB, KB, HFB, HKB 4-3/8 inch centre to centre. Order as a set of two special factory drilled breakers and 1 walking beam interlock. Specify breaker type, panel thickness and centre to centre dimension of breakers.
Centre Studs➀Sliding Bar Type (Field Mountable)➀➃
� Not CSA and UL listed.� 2000 amp maximum for PB breaker.� Not available on draw-out breakers.� Not available on motor operated breakers.
Availability: EB through PC
Mounts on panel (not included) fitting over front of breakers. Standard breaker spacing: LAB, LA, LC, HLC, MA, MC, NB, NC, HLA, HMA, HMC, HNB, HNC 8-1/2 inch centre to centre; DA, JA, KA, HKA, LB, LBB, HLB 5-3/4 inch centre to centre; EB, EHB, FB, HFB 4-3/16 inch centre to centre; JB, KB, HKB 4-3/8 inch centre to centre.
Kirk Key Interlock➃
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Accessories
48 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Motor Operators➀Motor operators provide complete remote control by means of a pushbutton or similar pilot device➁ . Positive switching action is accomplished by use of an operating arm engaging the breaker handle. The unit is energized momentarily to actuate the lever arm moving it to either the "ON" or "OFF" position. The control is broken by an internal cutoff switch. Means for emergency manual operations is provided.
Motor operators are available with motors rated 120 volts AC, 208 volts AC, and 240 volts AC.➂
The 480 volt operators utilize a 120 volt AC motor in conjunction with a 480/240 to 120 volt dual voltage transformer. (On LA and larger operators, the transformer is supplied for separate mounting by the customer.)
Note: The motor operator is intended only for infrequent operation in line with CSA and Underwriters Laboratories Inc. endurance standards for AB moulded case breakers. Minimum 1 kVA transformer is required for use with all motor operations.
For LAB, LA, HLA Breakers
For MA, HMA, NB,HNB Breakers
For PB Breakers
Motor Operator Selection
TypeBreaker
AC Voltage DC Voltage120 208 240 480 125 24Style Number Style Number Style Number Style Number Style Number Style Number
EB, EHB, FB, HFBDA, JA, KA, HKALB, LBB, HLBJB, KB, HKBLAB, LA, HLA, LC, HLCMA, HMA, MC, HMCNB, HNB, NC, HNCPB, PC, PCC
656D148G11657D819G23657D819G252600D28G072607D97G375664D54G751494D60G315661D52G01
656D148G04657D819G10657D819G162600D28G042607D97G405664D54G781494D60G325661D52G04
656D148G02657D819G08657D819G142600D28G022607D97G385664D54G761494D60G335661D52G02
656D148G13657D819G24657D819G262600D28G082607D97G395664D54G771494D60G345661D52G03
————2607D97G515664D54G961494D60G355661D52G17
————2607D97G425664D54G811494D60G36—
� AC voltage rated operators are CSA and UL listed as recognized components.� The pilot device must be maintained contact type for EB, EHB, FB, HFB, DA, JA, KA, JB, KB, HKB and LB mechanisms, momentary contact type for all others.� LA and larger available for 125 volts DC.
Dimensions: DS 29-170
Back Mounting Plates
TypeBreaker
120, 208, 240, 480 Volts ACStyle Number
EB, EHB, FB, HFBDA, JA, KA, LBJB, KB, HKB
503C707G01503C981G011250C26G01
For EB, EHB, FB and HFB
For DA, JA, KA, JB, LB, LBB, HKA,HKB and HLB Breakers
Motor Data
TypeBreaker
MotorInrush Current,Ampere (Peak)
ContinuousCurrent (RMS) Operating
Time, Openor CloseType Hp.
120Volts
208Volts
240Volts
120Volts
208Volts
240Volts
EB, EHB, FB, HFBDA, JA, KA, JB, KB, LB, LBB, HKB, HLBLAB, LA, HLAMA, HMA, NB, HNBPB
Split Phase
Split PhaseReversingReversingReversing
1/75
1/50———
10
14 81120
4
6 5 712
5
7 4 611
2.3
3.5———
1.17
1.6———
1.65
1.75———
1.5 Seconds
1.5 Seconds12 Cycles12 Cycles10 Cycles
Replacement AB DE-ION® Circuit Breakers
Accessories
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 49
494949494949494949494949494949494949494949494949494949494949
Optional Features
Safety Interlock➁This feature trips the breaker as the movable carrier frame is withdrawn, and must be factory installed. Order as follows.
For LA, MA and NB breakers➁Order standard stationary mounting frame. Order breaker and movable carrier frame assembled with safety interlock.
Secondary ContactsThese are used to disconnect auxiliary circuits when attachments such as shunt trip or motor operator are used. Available in multiples of four contacts with a maximum of 24 contacts for the LA 600 or 32 contacts for the MA and NB. They must be factory mounted. Order by description as similar to stationary or moving frame and specify number of contacts required.
Drawout Frame➀ These drawout frames are for use with standard 3-pole Cutler-Hammer® moulded case circuit breakers. They consist of two separate parts: stationary mounting frame and movable carrier frame. Slide rails are drawer-type, and a screw mechanism is used to engage or withdraw the movable carrier frame.
The drawout frames have three positions: connected, test and disconnected. The frames do not include a safety tripping interlock, or secondary contacts. These are optional items and may be ordered at additional cost.
Breakers mounted in the drawout frames can be equipped with standard breaker accessories including shunt trip, undervoltage release, auxiliary switch, alarm switch and motor operator.
Ordering Information➂
Standard InstallationOrder one stationary mounting frame and one movable carrier frame.
Order breakers without terminals or rear connectors.
Order any attachments desired (shunt trip, undervoltage release, etc.)
Order secondary contacts as required:
● a shunt trip, undervoltage release or alarm switch requires two contacts;
● a 1A-1B auxiliary switch requires three contacts;
● a motor operator requires a maximum of four contacts;
● others as required.
With Safety InterlockOrder stationary mounting frame and movable carrier frame as directed under Optional Features.
Racking CrankA special crank to engage or withdraw the moving portion of the drawout. A standard 1/2 inch hex socket with extension can be used for this purpose.
Style Number: 765A767G01
Cell Switches Mounted on Draw-out Frames, All Ratings
Up to four switches can be provided. Order by description.
Each switch provides NO and NC contact that transfers before reaching the test position when being withdrawn, and after the test position when being racked in.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Accessories
� These units are CSA and UL listed.� Safety interlock not available on MC, NC, HMC, HNC, LC, HLC� SELTRONIC� circuit breakers with built-in ground fault require a special breaker frame with leads out the side in place of standard terminal
block. Order by description the breaker frame and carrier as one assembly.� Factory installed only.
Selection Data➁➂
BreakerType
Stationary Mounting FrameStyle Number➁
Movable Carrier FrameStyle Number➁
LA600, HLA600, LC600, HLC600MA, HMA, MC, HMCNB, HNB, NC, HNCPB, PC, PCC 2000APB 2500A, PC, PCC 2500A and 3000A
2603D84G012603D85G012603D85G012601D18G042601D18G05
2608D35G062608D35G102608D34G08Order by description➃Order by description➃
50 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Here is an example of the new panelboard replacement circuit breaker catalogue numbering system.
1. An RF3100 is a newly manufactured, three-pole, 100 ampere trip panelboard replacement circuit breaker. It replaces an out-of-production F circuit breaker.
R F 3 100
R Designates New Panelboard Replacement Circuit Breaker
F Identifies the Out-of-Production Circuit Breaker Frame
3 Number of Poles
100 Trip Unit Ampere Rating
Panelboard replacement circuit breakers have non interchangeable trip units and the same interrupting capacity as the out-of-production circuit breakers they replace.
Replacement Chart
Current PanelboardCircuit Breaker Type
Out-of-ProductionCircuit Breaker Type➀
Volts AC(50/60 Hz)
240 480 600REAREREHRFARHFARFRHF
EAEEHFAHFAFHF
●●
●●●●●
Out-of-Production Circuit BreakersSeveral models of Westinghouse® moulded case circuit breakers are no longer manufactured. These circuit breakers are considered by Eaton to be out of production.
However, some firms have been offering Westinghouse out-of-production circuit breakers in a reconditioned state. These circuit breakers are not new units and may have been in service for extended periods of service time.
Moulded case circuit breakers are not designed to be repaired or calibrated in the field. When these circuit breakers are reconditioned by firms other than Eaton, it is extremely difficult to maintain the original factory specifications of the circuit breakers.
Replacement of Out-of-Production Circuit BreakersWhen out-of-production circuit breakers must be replaced, Eaton recommends one of these solutions:
● Upgrade or retrofit the equipment to use the most current moulded case circuit breaker technology. This includes the Series C� family of moulded case circuit breakers that have higher interrupting capacities in each frame size while being smaller and lighter.
● Use currently manufactured Cutler-Hammer® replacement industrial circuit breakers. They are available from stock and can be used to replace many out-of-production circuit breakers.
● Use Cutler-Hammer Panelboard Replacement Circuit Breakers in panelboards and small switchboards with group mounted circuit breaker distribution sections. These UL listed replacement circuit breakers are newly manufactured and are physically interchangeable with the circuit breakers they are designed to replace. (These circuit breakers may be suitable for other replacement applications as well.)
● Eaton strongly recommends that out-of-production circuit breakers be replaced with one of the newly manufactured circuit breakers described in the preceding paragraphs.
As a last resort, another alternative is to utilize out-of-production circuit breakers that have been reconditioned by Eaton at the original factory. Factory reconditioned breakers are available for all styles of out-of-production breakers (E, F, G, J, K, L, …). These breakers are not UL listed, but have been reconditioned and tested at the factory according to the manufacturing and engineering standards to which the original breakers were built.
Cutler-Hammer Panelboard Replacement Circuit Breakers are newly manufactured and tested to the latest applicable standards at the Eaton moulded case circuit breaker plant in Beaver, Pennsylvania. This plant has a long and well-recognized tradition of product safety, integrity and quality.
The panelboard replacement circuit breaker solution eliminates the need to consider alternative approaches. Eaton customers are assured that the high standards of product quality and reliability do not have to be sacrificed when replacing Westinghouse out-of-production circuit breakers.
All Panelboard Replacement Circuit Breakers are easily identified by the prefix “R” added to the out-of-production type circuit breaker catalogue number they replace.
� Last manufacture date – 1974.
Panelboard Replacement Breaker UL listed Interrupting Amp Ratings
BreakerType Amps
@ 120VoltsAC @ 240 Volts AC @ 277 Volts AC @ 480 Volts AC
@ 600VoltsAC
@ 125Volts DC
@ 125/250Volts DC
@ 250VoltsDC
(1-Pole) (1-Pole) (1-Pole)REREAREH
RF (2, 3, 4P)RFA (2, 3, 4P)RHF (2, 3P)RHFA (2, 3P)
15-10015-10015-100
15-10015-15015-10015-150
75007500
7500 (2, 3P) 7500 (2, 3P)14000 (2, 3P)
18000180006500065000
10000 (15, 20A)10000 (15, 20A)10000 10000 (2, 3P)
14000140002500025000
14000140001800018000
500050005000
5000 (2, 3P)5000 (2P)5000 (2, 3P) (70-100A)
10000100001000010000
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Panelboard Replacement Breakers UL Listed 100 and 150 Ampere Frames
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 51
494949494949494949494949494949494949494949494949494949494949
Notes1. The RE breaker has off-centre
terminals just like the E breaker it is replacing.
2. For out-of-production breakers, the “B” suffix denoted a long handle, however, the “B” suffix denotes 277 voltage rating for the Panelboard Replacement Breakers.
3. Some Panelboard Replacement Breakers do not have the same physical dimensions or mounting holes as the breakers they replace. For example, the types REH, RFA and RHFA are 6 inches in length and the breakers they replace, EH, FA and HFA are 6-1/2 inches in length. Mounting hardware is provided with each breaker to resolve these differences, and must be installed to ensure a proper fit.
Additional InformationSee instruction eaflets for detailed mounting information:
RE, REA I.L. 15558RF, RHF I.L. 15559REH, RFA, RHFA I.L. 15562RJ I.L. 15563RK, RHK I.L. 15564RKL, RHKL I.L. 15565RLM, RHLM I.L. 15566
Panelboard replacement breakers can be installed in the following styles of old Westinghouse® panelboards:
Note: This information covers most panelboards built by Westinghouse since 1937.
InstalledReplacementCircuit Breakers
PanelboardType
BranchCircuitBreakers
ABHA2BCDP
NABNAIBNAIB-LXNDPNEBNHDPNHEBNHIBNLAB-ABNLAB-ABH
EEEEAEHFAFEE, EAEE, EA, EAHEAEHEH/FAE-277EE
REREREREAREHRFARFRERE,REARERE,REA, REHREAREHREH, RFARERERE
Replacement AB DE-ION® Circuit Breakers
Panelboard Replacement Breakers UL Listed
52 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Type RE 1-, 2-, 3-Poles; 240-Volts AC Maximum; Thermal Magnetic
Continuous AmpereRating at 40°C
Catalogue Number1-Pole 120V 2-Pole 240V 3-Pole 240V
10 15 20 25 30 40 50 60 70 80 90100
RE1010RE1015RE1020RE1025RE1030RE1040RE1050RE1060RE1070RE1080RE1090RE1100
. . . . . . .RE2015RE2020RE2025RE2030RE2040RE2050RE2060RE2070RE2080RE2090RE2100
. . . . . . .RE3015RE3020RE3025RE3030RE3040RE3050RE3060RE3070RE3080RE3090RE3100
Type REH 1-, 2-, 3-Poles; 240-Volts AC Maximum; Thermal Magnetic
Continuous AmpereRating at 40°C
Catalogue Number1-Pole 277V 2-Pole 480V 3-Pole 480V
10 15 20 25 30 40 50 60 70 80 90100
REH1010REH1015REH1020REH1025REH1030REH1040REH1050REH1060REH1070REH1080REH1090REH1100
—REH2015REH2020REH2025REH2030REH2040REH2050REH2060REH2070REH2080REH2090REH2100
—REH3015REH3020REH3025REH3030REH3040REH3050REH3060REH3070REH3080REH3090REH3100
Type REA 1-, 2-, 3-Poles; 240-Volts AC Maximum; Thermal Magnetic
Continuous AmpereRating at 40°C
Catalogue Number1-Pole 120V 2-Pole 240V 3-Pole 240V
10 15 20 25 30 40 50 60 70 80 90100
REA1010REA1015REA1020REA1025REA1030REA1040REA1050REA1060REA1070REA1080REA1090REA1100
—REA2015REA2020REA2025REA2030REA2040REA2050REA2060REA2070REA2080REA2090REA2100
—REA3015REA3020REA3025REA3030REA3040REA3050REA3060REA3070REA3080REA3090REA3100
50°C Calibration➁Add suffix “V” to catalogue number for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.Factory reconditioned F and FA Tri-Pac styles are available.➁
Accessories and ModificationsAll accessories and modifications available for Replacement Breakers Types EB, EHB and FB are also available for Panelboard Replacement Breakers Types RE, REH, RFA, RF, RHF, REA and RHFA.
For accessories and modifications not listed on these pages, refer to SD 29-121 and SD 29-120 where applicable.
Replacement AB DE-ION® Circuit Breakers
Panelboard Replacement Breakers UL Listed
TerminalsBreakers include load terminals only. Panelboard replacement breaker terminals listed below are the same as the terminals used on replacement breakers Type EB, EHB, and FB.
Maximum BreakerAmps
Wire Type
Wire Range
Terminals
Style Number➀Standard Pressure Type Terminals
20 (EB, EHB)100150
Al/CuAl/CuAl/Cu
#14-#10#14-1/0# 4-4/0
624B100G14624B100G02624B100G17
Optional Al/Cu Pressure Terminals
50100
Al/CuAl/Cu
#14-#4# 4-4/0
624B100G10624B100G17
Shaded gray areas denotes obsolete or discontinued products and services� Package of 3.� Not listed with Underwriters Laboratories Inc.
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 53
494949494949494949494949494949494949494949494949494949494949
Type RFA 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-pole 600V 3-pole 600V
15 20 25 30 35 40 50 60 70 80 90100125150
RFA2015RFA2020RFA2025RFA2030RFA2035RFA2040RFA2050RFA2060RFA2070RFA2080RFA2090RFA2100RFA2125RFA2150
RFA3015RFA3020RFA3025RFA3030RFA3035RFA3040RFA3050RFA3060RFA3070RFA3080RFA3090RFA3100RFA3125RFA3150
Type RF 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-pole 600V 3-pole 600V
15 20 25 30 35 40 50 60 70 80 90100
RF2015RF2020RF2025RF2030RF2035RF2040RF2050RF2060RF2070RF2080RF2090RF2100
RF3015RF3020RF3025RF3030RF3035RF3040RF3050RF3060RF3070RF3080RF3090RF3100
Type RHFA 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-pole 600V 3-pole 600V
15 20 25 30 35 40 50 60 70 80 90100125150
RHFA2015RHFA2020RHFA2025RHFA2030RHFA2035RHFA2040RHFA2050RHFA2060RHFA2070RHFA2080RHFA2090RHFA2100RHFA2125RHFA2150
RHFA3015RHFA3020RHFA3025RHFA3030RHFA3035RHFA3040RHFA3050RHFA3060RHFA3070RHFA3080RHFA3090RHFA3100RHFA3125RHFA3150
Type RHF 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-pole 600V 3-pole 600V
15 20 25 30 40 50 60 70 80 90100
RHF2015RHF2020RHF2025RHF2030RHF2040RHF2050RHF2060RHF2070RHF2080RHF2090RHF2100
RHF3015RHF3020RHF3025RHF3030RHF3040RHF3050RHF3060RHF3070RHF3080RHF3090RHF3100
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Panelboard Replacement Breakers UL Listed
54 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Panelboard Replacement Breakers UL Listed
Type RJ 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-Pole 600V 3-Pole 600V
70 90100125150175200225225 MCS
RJ2070RJ2090RJ2100RJ2125RJ2150RJ2175RJ2000RJ2225RJ2225K
RJ3070RJ3090RJ3100RJ3125RJ3150RJ3175RJ3200RJ3225RJ3225K
Type RKL 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-Pole 600V 3-Pole 600V
125150175200225250300350400400 MCS
RKL2125RKL2150RKL2175RKL2200RKL2225RKL2250RKL2300RKL2350RKL2400RKL2400K
RKL3125RKL3150RKL3175RKL3200RKL3225RKL3250RKL3300RKL3350RKL3400RKL3400K
Type RK 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-Pole 600V 3-Pole 600V
70 90100125150175200225225 MCS
RK2070RK2090RK2100RK2125RK2150RK2175RK2200RK2225RK2225K
RK3070RK3090RK3100RK3125RK3150RK3175RK3200RK3225RK3225K
Type RLM 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-Pole 600V 3-Pole 600V
125150175200225250275300350400500600600 MCS700800
RLM2125RLM2150RLM2175RLM2200RLM2225RLM2250RLM2275RLM2300RLM2350RLM2400RLM2500RLM2600RLM2600KRLM2700RLM2800
RLM3125RLM3150RLM3175RLM3200RLM3225RLM3250RLM3275RLM3300RLM3350RLM3400RLM3500RLM3600RLM3600KRLM3700RLM3800
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 55
494949494949494949494949494949494949494949494949494949494949
Type RHLM 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-pole 600V 3-pole 600V
125150175200225250275300325350400450500550600600 MCS700800
RHLM2125RHLM2150RHLM2175RHLM2200RHLM2225RHLM2250RHLM2275RHLM2300RHLM2325RHLM2350RHLM2400RHLM2450RHLM2500RHLM2550RHLM2600RHLM2600KRHLM2700RHLM2800
RHLM3125RHLM3150RHLM3175RHLM3200RHLM3225RHLM3250RHLM3275RHLM3300RHLM3325RHLM3350RHLM3400RHLM3450RHLM3500RHLM3550RHLM3600RHLM3600KRHLM3700RHLM3800
Type RHKL 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-pole 600V 3-pole 600V
125150175200225250300350400400 MCS
RHKL2125RHKL2150RHKL2175RHKL2200RHKL2225RHKL2250RHKL2300RHKL2350RHKL2400RHKL2400K
RHKL3125RHKL3150RHKL3175RHKL3200RHKL3225RHKL3250RHKL3300RHKL3350RHKL3400RHKL3400K
Type RHK 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous Ampere Rating at 40°CCatalogue Number2-pole 600V 3-pole 600V
70 90100125150175200225225 MCS
RHK2070RHK2090RHK2100RHK2125RHK2150RHK2175RHK2200RHK2225RHK2225K
RHK3070RHK3090RHK3100RHK3125RHK3150RHK3175RHK3200RHK3225RHK3225K
Special Breakers➁
Magnetic Only (includes Load Terminals). Available for all ampere ratings for 2- and 3-pole RJ, RK, RKL, RLM, RHK, RHKL, and RHLM.
High magnetic Moulded Case Switches (K suffix) are available to replace out-of-production non-automatic breakers (N suffix).
Factory reconditioned K, KL and L Tri-Pac styles also available.➁
Accessories and ModificationsAll accessories and modifications available for Replacement Breakers Types KA, LA and MA are also available for Panelboard Replacement Breakers Types RJ, RK, RKL, RLM, RHK, RHKL, and RHLM.
For accessories and modifications not listed on these pages, refer to SD 29-121 and SD 29-120 where applicable.
TerminalsPanelboardCircuit Breakers Terminals➀
RJRKRHKRKLRHKLRLMRHLM
TA225LA1TA225LA1TA225LA1TA400LA1TA400LA1TA700MA1 (for <600A)TA800MA1 (for 700-800A)
� Packaged individually.� Not listed with Underwriters Laboratories Inc.
50°C Calibration➁
Add suffix “V” to catalogue number for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Panelboard Replacement Breakers UL Listed
} {
56 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Panelboard replacement circuit breakers have non interchangeable trip units and the same interrupting capacity of the out-of-production circuit breakers they replace.
Notes
Some panelboard replacement breakers do not have the same physical dimensions or mounting holes as the breakers they replace. Mounting hardware is provided with each breaker to resolve these differences, and must be installed to ensure a proper fit.
Replacement Chart
Current Panelboard Circuit Breaker Type
Out-of-Production Circuit Breaker Type➀
Volts AC (50/60 Hz)
600RJRKRHKRKLRHKLRLMRHLMHLAHLA
JKHKKLHKLLM and LHLMJKJKL
●●●●●●●●●
Panelboard Replacement Breaker Interrupting Amp Ratings
BreakerType Amps
@ 240 VAC Sym
@ 240 VAC Asym
@ 480 VAC Sym
@ 480 VAC Asym
@ 600 VAC Sym
@ 600 VAC Asym
@ 250VDC
RJRJKRJKL
RKRKLRLM
RHKRHKLRHLM
70-225 70-225125-400
70-225125-400125-800
70-225125-400125-800
220002500042000
250004200040000
650006500065000
250003000050000
300005000050000
750007500075000
180002200030000
220003000030000
350003500035000
200002500035000
250003500035000
400004000040000
140002200022000
220002200022000
250002500025000
150002500025000
250002500025000
300003000030000
100001000020000
100002000020000
200002000020000
Panelboard replacement breakers can be installed in the following styles of old Westinghouse® lighting panelboards:
ABHNEBA2BNHDPNABNHEBNA1BNH1BNA1B-LXNLAB-ABNDPNLAB-ABH
These breakers can be installed as vertical main breakers or as vertically mounted subfeed breakers.
� Last manufacture date – 1967
Replacement AB DE-ION® Circuit Breakers
Panelboard Replacement Breakers UL Listed 225 to 800 Ampere Frames
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 57
494949494949494949494949494949494949494949494949494949494949
Here is an example of the new Motor Control Centre Replacement Circuit Breaker catalogue numbering system.
1. An RMCF3100 is a newly manufactured, three-pole, 100 ampere trip panelboard replacement circuit breaker. It replaces an out-of-production F circuit breaker.
RMC F 3 100
RMC Designates new MotorControl centre Replacement Circuit Breaker
F Identifies the Out-of-Production Circuit Breaker Frame
3 Number of Poles
100 Trip Unit Ampere Rating
Motor Control Centre Replacement Circuit Breakers have non interchangeable trip units and the same interrupting capacity as the out-of-production circuit breakers they replace.
Replacement chart
Current MCC Circuit Breaker Type
Out-of-ProductionCircuit Breaker Type➀
Volts AC(50/60 Hz)
600RMCFARMCHFARMCFRMCHF
FAHFAFHF
●●●●
Out-of-Production Circuit BreakersSeveral models of Westinghouse® moulded case circuit breakers are no longer manufactured. These circuit breakers are considered by Eaton to be out of production.
However, some firms have been offering Westinghouse out-of-production circuit breakers in a reconditioned state. These circuit breakers are not new units and may have been in service for extended periods of service time.
Westinghouse moulded case circuit breakers are not designed to be repaired or calibrated in the field. When these circuit breakers are reconditioned by firms other than Eaton, it is extremely difficult to maintain the original factory specifications of the circuit breakers.
Replacement of Out-of-Production Circuit BreakersWhen out-of-production circuit breakers must be replaced, Eaton recommends one of these solutions:
● Upgrade or retrofit the equipment to use the most current moulded case circuit breaker technology. This includes the Series C� family of moulded case circuit breakers that have higher interrupting capacities in each frame size while being smaller and lighter.
● Use currently manufactured Cutler-Hammer® replacement industrial circuit breakers. They are available from stock and can be used to replace many out-of-production circuit breakers.
● Use Cutler-Hammer Motor Control Replacement Circuit Breakers in motor control centers. These UL listed replacement circuit breakers are newly manufactured and are physically interchangeable with the circuit breakers they are designed to replace. (These circuit breakers may be suitable for other replacement applications as well.)
● Eaton strongly recommends that out-of-production circuit breakers be replaced with one of the newly manufactured circuit breakers described in the preceding paragraphs.
Cutler-Hammer Motor Control Centre Replacement Circuit Breakers are newly manufactured and tested to the latest applicable standards at the Eaton moulded case circuit breaker plant in Beaver, Pennsylvania. This plant has a long and well-recognized tradition of product safety, integrity and quality.
The Motor Control Centre Replacement Circuit Breaker solution eliminates the need to consider alternative approaches. Eaton customers are assured that the high standards of product quality and reliability do not have to be sacrificed when replacing Westinghouse out-of-production circuit breakers.
All Motor Control Centre Replacement Circuit Breakers are easily identified by the prefix “RMC” added to the out-of-production type circuit breaker catalogue number they replace.
As a last resort, another alternative is to utilize out-of-production circuit breakers that have been reconditioned by Westinghouse at the original factory. Factory reconditioned breakers are available for all styles of out-of-production breakers (E, F, G, J, K, L, . . .). These breakers are not UL listed, but have been reconditioned and tested at the factory according to the manufacturing and engineering standards to which the original breakers were built.
� Last manufacture date – 1974.
Motor Control Centre Replacement Breaker Interrupting Amp Ratings
Breaker Type Amps
@ 240Volts AC
@ 480Volts AC
@ 600Volts AC
@ 250Volts DC
RMCFRMCFARMCHFRMCHFA
15-10015-15015-10015-150
18000180006500065000
14000140002500025000
14000140001800018000
10000100002000020000
Replacement AB DE-ION® Circuit Breakers
Motor Control Centre Replacement Breakers UL Listed
Shaded gray areas denotes obsolete or discontinued products and services
58 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
NotesMotor Control Centre Replacement Breakers do not have the same physical dimensions or mounting holes as the breakers they replace. Types RMCFA and RMCHFA are 6 inches in length and the breakers they replace, FA and HFA, are 61⁄2 inches in length. Types RMCF and RMCHF are 6 inches in length and the breakers they replace, F and HF, are 93⁄8 inches in length. A mounting plate is provided with each breaker to resolve these differences, and must be installed to ensure a proper fit.
RMCFA and RMCHFA 2 pole breakers are supplied in a 3 pole frame with current carrying parts omitted from the centre pole.
Additional InformationSee instruction leaflets for detailed mounting information:RMCF, RMCHF I.L. 15582RMCFA, RMCHFA I.L. 15583
Replacement AB DE-ION® Circuit Breakers
Motor Control Centre Replacement Breakers UL Listed
Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca 59
494949494949494949494949494949494949494949494949494949494949
Type RMCF 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous AmpereRating at 40°C
Catalogue Number1-pole 2-pole 3-pole
15 20 25 30 35 40 50 60 70 80 90100
————————————
RMCF2015RMCF2020RMCF2025RMCF2030RMCF2035RMCF2040RMCF2050RMCF2060RMCF2070RMCF2080RMCF2090RMCF2100
RMCF3015RMCF3020RMCF3025RMCF3030RMCF3035RMCF3040RMCF3050RMCF3060RMCF3070RMCF3080RMCF3090RMCF3100
Type RMCFA 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous AmpereRating at 40°C
Catalogue Number1-pole 2-pole 3-pole
15 20 25 30 35 40 50 60 70 80 90100125150
——————————————
RMCFA2015RMCFA2020RMCFA2025RMCFA2030RMCFA2035RMCFA2040RMCFA2050RMCFA2060RMCFA2070RMCFA2080RMCFA2090RMCFA2100RMCFA2125RMCFA2150
RMCFA3015RMCFA3020RMCFA3025RMCFA3030RMCFA3035RMCFA3040RMCFA3050RMCFA3060RMCFA3070RMCFA3080RMCFA3090RMCFA3100RMCFA3125RMCFA3150
Type RMCHFA 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous AmpereRating at 40°C
Catalogue Number1-pole 2-pole 3-pole
15 20 25 30 35 40 50 60 70 80 90100125150
——————————————
RMCHFA2015RMCHFA2020RMCHFA2025RMCHFA2030RMCHFA2035RMCHFA2040RMCHFA2050RMCHFA2060RMCHFA2070RMCHFA2080RMCHFA2090RMCHFA2100RMCHFA2125RMCHFA2150
RMCHFA3015RMCHFA3020RMCHFA3025RMCHFA3030RMCHFA3035RMCHFA3040RMCHFA3050RMCHFA3060RMCHFA3070RMCHFA3080RMCHFA3090RMCHFA3100RMCHFA3125RMCHFA3150
Replacement AB DE-ION® Circuit Breakers
Motor Control Centre Replacement Breakers UL Listed
Shaded gray areas denotes obsolete or discontinued products and services
60 Replacement AB DE-ION® Circuit Breakers PG.22D.02.S.K.—June 2010 www.eatoncanada.ca
494949494949494949494949494949494949494949494949494949494949
Type RMCHF 2-, 3-Poles; 600-Volts AC Maximum; Thermal Magnetic
Continuous AmpereRating At 40°c
Catalogue Number1-pole 2-pole 3-pole
15 20 25 30 35 40 50 60 70 80 90100
————————————
RMCHF2015RMCHF2020RMCHF2025RMCHF2030RMCHF2035RMCHF2040RMCHF2050RMCHF2060RMCHF2070RMCHF2080RMCHF2090RMCHF2100
RMCHF3015RMCHF3020RMCHF3025RMCHF3030RMCHF3035RMCHF3040RMCHF3050RMCHF3060RMCHF3070RMCHF3080RMCHF3090RMCHF3100
Accessories and Modifications
Description: Pages 39 - 49
All accessories and modifications available for Replacement Breakers Type FB and HFB are also available for Motor Control Centres Replacement Breakers Types RMCFA, RMCHFA, RMCF, and RMCHF.
TerminalsBreakers include both line and load terminals. See Terminal data for Replacement Breaker Type FB.
50°C Calibration
Add suffix “V” to catalogue number for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50°C ambients. Same price as standard 40°C breakers.
Special Breakers➀
Magnetic Only, Front Adjustable (includes Line and Load Terminals). Available for 15-150 ampere ratings for 2- and 3-pole RMCF, RMCHF, RMCFA and RMCHFA.
Factory reconditioned F and FA Tri-Pac styles also available.➀
� Not listed with CSA and Underwriters Laboratories Inc.
Shaded gray areas denotes obsolete or discontinued products and services
Replacement AB DE-ION® Circuit Breakers
Motor Control Centre Replacement Breakers UL Listed
© 2010 Eaton CorporationAll Rights ReservedPrinted in CanadaPub No. PG.22D.02.S.K.June 2010
Eaton Corporation5050 MainwayBurlington, ON L7L 5Z1Canada
Replacement AB DE-ION® Circuit Breakers
Product Focus 2010
Eaton’s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton’s full-scale engineering services, these products provide customer-driven PowerChain Management® solutions to serve the power system needs of the data centre, industrial, institutional, public sector, utility, commercial, residen-tial, IT, mission critical, alternative energy and OEM markets worldwide.
PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eatoncanada.ca
Replacement Circuit Breakers Cover 2010.indd 1 8/19/10 6:17:08 PM
top related