ec type-approval certificate uk 3005 · ec type-approval certificate uk 3005 issued by the:...

Post on 26-Sep-2020

0 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

UK 3005

V(0)a

Issue Date: Valid Until: Reference No:

22 June 2015 21 June 2025 TS1202/0086

G Glas

Technical Manager - Certification Services For and on behalf of the Chief Executive

0135

National Measurement & Regulation Office I Stanton Avenue I Teddington I TW11OJZ I United Kingdom Tel +44 (0) 20 8943 7272 I Fax +44 (0) 20 8943 7270 I Web www.gov.uk/nmro

The NMRO is an Executive Agency of the Department for Business Innovation and Skills

NAWI Rev. 5 01 April 2015

EC Type-Approval Certificate UK 3005

Issued by the: National Measurement Office Notified Body Number 0126

In accordance with the requirements of the Non-Automatic Weighing Instruments Regulations 2000 (SI 2000/3236) which implement, in the United Kingdom, Council Directive 2009/23/EC, this EC Type-Approval Certificate has been issued to:

WAAGEN Frank GmbH St.Ruprechterstrasse 67 9020 Klagenfurt Austria

In respect of a family of Non-Automatic Weighing Instruments designated the EWT2, EWT3, EWT4 and EWT5 Series having the following characteristics:

n ≤ 10 000 for single interval, Class III

n ≤ 1 000 for single interval, Class IIII

The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

2/32

Descriptive Annex

1 NAME AND TYPE OF INSTRUMENT

The designated certified weight indicators are designed to be connected to a load receptor to form a Class III and IIII, Non-Automatic Weighing Instrument. The instruments can either be mains or DC battery-powered, self-indicating, Non-Automatic Weighing Instruments.

The indicators consists of analogue to digital conversion circuitry, microprocessor control circuitry, power supply, keyboard, non-volatile memory for storage of calibration and setup data, and a weight display contained within a single enclosure.

2 FUNCTIONAL DESCRIPTION

2.1 Construction and devices

The digital weight indicators are fully described in EC Test Certificate GB-1549.

Indicator ID Alternative ID

EWT5 3590

EWT4 CPWE

EWT2 DFW

EWT3 DGT

2.2 Load cell

Any compatible load cell(s) may be used providing the following conditions are met:

There is a respective OIML Certificate of Conformity (R60) or a test certificate (EN: 45501) issued for the load cell by a Notified Body responsible for type examination under Directive 2009/23/EC.

The certificate contains the load cell types and the necessary load cell data required for the manufacturer’s declaration of compatibility of modules (WELMEC 2, Issue 5, 2009, No 11), and any particular installation requirements. A load cell marked NH is allowed only if humidity testing to EN45501 has been conducted on this load cell.

The compatibility of the load cells and indicator is established by the manufacturer by means of the compatibility of modules calculation, contained in the above WELMEC 2 document, at the time of verification or declaration of EC conformity of type.

The load cell transmission must conform to one of the examples shown in the WELMEC Guide 2.4, “Guide for Load cells”.

3/32

2.3 Digital load cells

The EWT5 series indicators may be connected through the serial line with up to 64 digital cells which may be of the following: Manufacturer Model Test Certificate Issued by

FLINTEC RC3D TC6586 NMi

HBM C16i D09-00.46 PTB

SCAIME CB50X-DL TC7078 NMi

DINI ARGEO RCD TC7547 NMi

When digital load cells are used the number of verification scale intervals is limited to the number specified in the applicable Test Certificate.

3 TECHNICAL DATA

3.1 Technical data for the indicator is provided in EC Test Certificate GB-1549.

4 PERIPHERAL DEVICES AND INTERFACES

4.1 Interfaces

4 or 6-wire load cell connection

DC voltage input

RS-232

RS-485

Control inputs/outputs

USB

Ethernet

Bluetooth

RF (Radio frequency)

WiFi

4.2 Peripheral devices

4.2.1 The following peripheral devices may be connected to the interfaces provided:

Peripheral devices that have been issued with a EC Test Certificate by a Notified Body responsible for type approval under Directive 2009/23/EC; or

Peripheral devices without a EC Test Certificate under the following conditions:

- it bears the CE marking for conformity to the EMC Directive;

- it is not capable of transmitting any data or instruction into the weighing instrument, other than to release a printout, checking for correct data transmission or validation;

- it prints weighing results and other data as received from the weighing instrument without any modification or further processing;

- it complies with the applicable requirements of EN: 45501, i.e. 4.2, 4.4, 4.6 and 4.7.

A printing device may print additional information such as date or number to identify the printed weighing result(s) or sets of weighing results.

4/32

5 APPROVAL CONDITIONS

This certificate is issued subject to the following conditions:

5.1 Legends and inscriptions

5.1.1 The remote display bears the following legends on or near the display:

Max Min e =

5.1.2 The instrument shall bear the following legends:

Accuracy class CE marking Green M Serial number Manufacturer’s mark or name Certificate number Other required markings, e.g. temperature, tare, where applicable The markings and inscriptions shall fulfil the requirements of Paragraph 1 of Annex IV of the Directive 2009/23/EC.

6 LOCATION OF SEALS AND VERIFICATION MARKS

6.1 The data plate is secured, either by sealing or by being of a form such that it is destroyed when removed.

6.2 Components that may not be dismantled or adjusted by the user must be secured. Common serial numbers, a wire and seal solution or a suitable mark may be used. The securing mark may be either:

a mark of the manufacturer and/or manufacturer’s representative, or

an official mark of a verification officer.

6.3 Verification marks and CE-marking shall be grouped together.

6.4 When software sealing is used, the CONFIG and CAL counters’ values shall be written on a tamper-evident label on or near the rating plate.

7 ALTERNATIVES

There are currently no authorised alternatives.

5/32

8 ILLUSTRATIONS

Figure 1 EWT5 Indicator

Figure 2 EWT4 Indicator

Figure 3 EWT2Indicator

Figure 4 EWT3 Indicator

Figure 5 Example of legal markings

Figure 6 EWT2 ABS Case version 1

Figure 7 EWT2 ABS Case version 2

Figure 8 EWT2 ABS Case version 3

Figure 9 EWT2 Stainless steel case version 1

Figure 10 EWT2 Stainless steel case version 2

Figure 11 EWT2 Stainless steel case version 3

Figure 12 EWT2 Stainless steel case version 4

Figure 13 EWT2 Stainless steel case version 5

Figure 14 EWT2 Metal case version

Figure 15 EWT5 ABS case version 1

Figure 16 EWT5 ABS case version 2

Figure 17 EWT5/EWT2 series - ABS case version 3

Figure 18 EWT5 Stainless steel case version 1

Figure 19 EWT5 series - Stainless steel case and graphic touch (example case 2)

Figure 20 EWT5 series - ABS case version and graphic touch (example case 4)

Figure 21 EWT4 series - Aluminum case version

Figure 22 EWT5 Series – Stainless steel case and graphic touch (example case 3)

Figure 23 EWT4 series - Stainless steel case version

Figure 24 EWT3 series - Plastic case version (example case 1)

Figure 25 EWT3 series - Plastic case version (example case 2)

Figure 26 EWT3 series - Plastic case version (example case 3)

Figure 27 EWT3 series - Plastic case version (example case 4)

Figure 28 EWT3 series – Metal case version (example case 1)

Figure 29 EWT3 series – Metal case version (example case 2)

Figure 30 EWT3 series - Stainless steel case version (example case 1)

Figure 31 Examples of connections between indicators and load cells

9 CERTIFICATE HISTORY

Issue №. Date Description

UK 3005 22 June 2015 Type approval first issued.

-- -- No revisions have been issued.

6/32

Figure 1 EWT5 family of indicators

Figure 2 EWT4 family of indicators

7/32

Figure 3 EWT2 family of indicators

Figure 4 EWT3 family of indicators

8/32

Figure 5 Example of legal markings

Or

*Control mark on electronic board.

Figure 6 EWT2 ABS Case version 1

9/32

Figure 7 EWT2 ABS case version 2

10/32

Figure 8 EWT2 ABS case version 3

11/32

or

Figure 9 – ETW2 series - Stainless steel case version 1

or

12/32

*Control mark on electronic board.

Figure 10 EWT2 Stainless steel case version 2

13/32

Figure 11 – EWT2 series - Stainless steel case version 3

14/32

Figure 12– EWT2 series - Stainless steel case version 4

15/32

Figure 13 – EWT2 series - Stainless steel case version 5

16/32

Figure 14 – EWT2 series - Metal case version

17/32

Figure 15 EWT5 ABS case version 1

18/32

Figure 16 – EWT5 series - ABS case version 2

19/32

Figure 17 – EWT5/EWT2 series - ABS case version 3

20/32

Figure 18 – EWT5 series - Stainless steel case version 1

21/32

Figure 19 – EWT5 series - Stainless steel case and graphic touch (example case 2)

22/32

Figure 20 – EWT5 series - ABS case version and graphic touch (example case 4)

23/32

Figure 21 – EWT4 series - Aluminum case version

24/32

Figure 22 – EWT5 Series – Stainless steel case and graphic touch (example case 3)

25/32

Figure 23 – EWT4 series - Stainless steel case version

Figure 24 – EWT3 series - Plastic case version (example case 1)

26/32

Figure 25 – EWT3 series - Plastic case version (example case 2)

27/32

Figure 26 – EWT3 series - Plastic case version (example case 3)

28/32

Figure 27 – EWT3 series - Plastic case version (example case 4)

29/32

Figure 28 – EWT3 series – Metal case version (example case 1)

30/32

Figure 29 – EWT3 series – Metal case version (example case 2)

31/32

Figure 30 – EWT3 series - Stainless steel case version (example case 1)

32/32

Figure 31 Examples of connections between indicators and load cells

© Crown Copyright 2015 National Measurement and regulation Office Department for Business, Innovation & Skills

top related