ed101 - rpr constructionrprconstruction.com/wp-content/.../2017/09/ssbd04-electrical-plans.pdf ·...
Post on 20-Aug-2018
216 Views
Preview:
TRANSCRIPT
A.1 A.1
CU CU
CU
<E>
<E>
<R>
EXISTING PANEL "M"
FUR
FUR
<E>
<E>
<R>
1
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
09/11/17
JOB NUMBER
SHEET NUMBER
16.093
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
DO
WN
TO
WN
B
RA
NC
H
TY
LE
R, T
EX
AS
SHEET REVISION HISTORY
PROJECT MANAGER
PAIGE ENGEL
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROBBIN K. CASSITY, P.E.
84344
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-022
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0"
ELECTRICAL
DEMOLITION PLANS
ED101
1. EXISTING PANEL "M" TO REMAIN. DEMO SERVICE
CONDUITS FROM THE METER TO PANEL "M".
(APPLICABLE TO THIS DRAWING ONLY)
A. REMOVE ALL EXISTING LIGHT FIXTURES, SWITCHES,
DISCONNECTS, RECEPTACLES, TELEPHONE OUTLETS, DATA
OUTLETS, AND ASSOCIATED CONDUITS AND WIRING IN WALLS BEING
REMOVED AND AS INDICATED IN DEMOLITION AREA, U.O.N..
B. ALL SALVAGEABLE MATERIALS FROM THE ELECTRICAL
DEMOLITION SHALL REMAIN THE PROPERTY OF THE OWNER.
CONTRACTOR SHALL REMOVE ALL UNWANTED ITEMS THE OWNER
DOES NOT WISH TO RETAIN AND PROPERLY DISPOSE OF OFFSITE.
FLUORESCENT LAMPS AND BALLASTS SHALL BE DISPOSED OF IN
ACCORDANCE WITH EPA GUIDELINES.
C. LIGHTING AND RECEPTACLE CIRCUITS BEING DEMO'D SHALL BE
REMOVED BACK TO ITS ORIGINATION POINT.
NOTE:
THESE PLANS DO NOT ATTEMPT TO DELINEATE THE FULL
EXTENT OF EXISTING ELECTRICAL DEVICES, EQUIPMENT,
AND LIGHTING TO BE REMOVED. FIELD VERIFY EXISTING
CONDITIONS AND ACCOUNT FOR SUCH IN BID PRICE.
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
09/11/17
JOB NUMBER
SHEET NUMBER
16.093
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
DO
WN
TO
WN
B
RA
NC
H
TY
LE
R, T
EX
AS
SHEET REVISION HISTORY
PROJECT MANAGER
PAIGE ENGEL
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROBBIN K. CASSITY, P.E.
84344
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-022
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
ELECTRICAL
GENERAL NOTES
E101
AF
AFF
AFG
AIC
AL
AS
AT
ATS
AWG
BCG
BLDG
C
CB
CKT
CL
CLR
CO
CSFD
CTR
CU
DIA
DP
DWG
EMS
EMT
ELR
EPO
EPR
EQ
FA
FAAP
FACP
FAPS
FARP
FLA
FVNR
G
GALV
RGS
GFI
HD
HH
HID
HO
HOA
HP
HPS
HSP
HV
HZ
IC
ISC
IG
INST
JB
AMPERE FRAME/FUSE
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMPS INTERRUPTING CURRENT
ALUMINUM
AMPERE SWITCH
AMPERES TRIP
AUTOMATIC TRANSFER SWITCH
BARE COPPER GROUND
BUILDING
CONDUIT
CIRCUIT BREAKER
CIRCUIT
CENTER LINE
CLEAR
CONDUIT ONLY
COMBINATION SMOKE/FIRE DAMPER
CENTER
COPPER
DIAMETER
DISTRIBUTION PANEL
ENERGY MANAGEMENT SYSTEM
ELECTRICAL METALLIC TUBING
END-OF-LINE RESISTOR
EMERGENCY POWER OFF
ETHYLENE PROPYLENE RUBBER
EQUAL
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FIRE ALARM POWER SUPPLY
FIRE ALARM REMOTE PANEL
FULL LOAD AMPERES
FULL VOLTAGE NON-REVERSING
GROUND
GALVANIZED
RIGID GALVANIZED STEEL
GROUND FAULT INTERRUPTER
HANDHOLE
HIGH INTENSITY DISCHARGE
HIGH OUTPUT
HAND-OFF-AUTO
HORSEPOWER
HIGH PRESSURE SODIUM
HOUSE SERVICE PANEL
HIGH VOLTAGE
HERTZ
INTERCOM
INTERRUPTING SHORT CIRCUIT
ISOLATED GROUND
INSTANTANEOUS
JUNCTION BOX
KV
KVA
KW
KWH
LCP
MCB
MCC
MCCB
MCP
MH
MIC
MLO
MSB
MSG
N
NC
NIC
NL
NO
NTS
OC
OH
PA
PB
PH.
POC
PVC
REC
REQ'D
RSC
SEC
SWBD
SYM
TD
TTB
TTC
UG
UL
UON
VFD
W/
WH
WP
XFMR
XLPE
XP
+4'-6"
KILOVOLTS
KILOVOLT-AMPERES
KILOWATTS
KILOWATT-HOURS
LIGHTING CONTROL PANEL
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOLDED CASE CIRCUIT BREAKER
MOTOR CIRCUIT PROTECTOR
MANHOLE
MICROPHONE
MAIN LUGS ONLY
MAIN SWITCHBOARD
MAIN SWITCHGEAR
NEUTRAL
NORMALLY CLOSED
NOT IN CONTRACT
NIGHT LIGHT (NON-SWITCHED)
NORMALLY OPEN, NUMBER
NOT TO SCALE
ON CENTER
OVERHEAD
PUBLIC ADDRESS
PUSHBUTTON
PHASE
POINT OF CONNECTION
POLYVINYL CHLORIDE
RECEPTACLE
REQUIRED
RIGID STEEL CONDUIT
SECONDARY
SWITCHBOARD
SYMMETRICAL
TIME DELAY
TELEPHONE TERMINAL BOARD
TELEPHONE TERMINAL CABINET
UNDERGROUND
UNDERWRITERS LABORATORIES
UNLESS OTHERWISE NOTED
VARIABLE FREQUENCY DRIVE
WITH
WATER HEATER
WEATHERPROOF
TRANSFORMER
CROSS LINKED POLYETHYLENE
EXPLOSION PROOF
TYPICAL MOUNTING HEIGHT 4'-6" ABOVE
FLOOR OR GRADE TO CENTER OF BOX
HEAT DETECTOR
DRAWING
AMERICAN WIRE GAUGE
(APPLICABLE TO ALL ELECTRICAL DRAWINGS)
THE PLANS AND SPECIFICATIONS ARE ISSUED AS A COMPLETE SET. THE CONTRACTOR SHALL THOROUGHLY REVIEW THE COMPLETE SET OF
DOCUMENTS IN ASCERTAINING THE SCOPE OF WORK AND IN COORDINATION OF HIS WORK WITH THAT OF OTHER TRADES. ANY CONFLICTS
SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR RESOLUTION.
PRIOR TO SUBMITTING A BID THE CONTRACTOR SHALL VISIT THE SITE, REVIEW THE EXISTING CONDITIONS AND ALLOW FOR LABOR, MATERIAL
AND COORDINATION THAT IS NECESSARY TO PROVIDE A COMPLETE AND INTEGRATED INSTALLATION OF EACH SYSTEM. CONTRACTOR SHALL
TAKE CARE IN ASCERTAINING THE REQUIREMENTS TO INTEGRATE NEW DEVICES OR SYSTEMS WITH EXISTING.
REFER TO THE CONTRACT DRAWINGS FOR LOCATIONS AND SPACE REQUIREMENTS OF ELECTRICAL EQUIPMENT. COORDINATE THE
INSTALLATION OF ELECTRICAL EQUIPMENT WITH OTHER TRADES.
POWER FEEDERS MAY NOT BE SHOWN ON THE DRAWINGS. REFER TO PANEL SCHEDULES OR THE SINGLE LINE DIAGRAM FOR CONDUIT AND
FEEDER INFORMATION.
WHERE FIXTURE QUANTITIES ARE SHOWN ON DRAWINGS THEY ARE FOR AREA FIXTURE TYPE REFERENCE ONLY. CONTRACTOR IS
RESPONSIBLE FOR FIXTURE COUNT AND SHALL VERIFY ALL FIXTURE QUANTITIES PRIOR TO BIDDING.
LIGHT FIXTURES ARE SHOWN IN APPROXIMATE LOCATIONS. THE CONTRACTOR SHALL REFERENCE THE ARCHITECTURAL REFLECTED CEILING
PLAN, BUILDING ELEVATIONS, AND DETAILS FOR EXACT HEIGHT AND LOCATIONS.
RECESSED LIGHT FIXTURES INSTALLED IN LAY-IN CEILINGS SHALL BE PROVIDED WITH GRID CLIPS, EVEN IF NOT SPECIFICALLY IDENTIFIED IN
THE FIXTURE MODEL NUMBER.
WHERE SHOWN, THE NUMBER ADJACENT TO LIGHT FIXTURES REPRESENTS THE CIRCUIT NUMBER AND THE LETTER REPRESENTS THE
SWITCH CONTROLLING THE FIXTURE. EMERGENCY BALLASTS, EXIT LIGHTING, AND EMERGENCY LIGHTS SHALL NOT BE SWITCHED AND SHALL
BE CONNECTED TO THE CIRCUIT INDICATED.
ALL EXIT SIGNS AND THE EMERGENCY LAMP OF FIXTURES INDICATED BY "NL" SHALL BE CONNECTED UNSWITCHED. OTHERWISE, ONE LAMP
OF ALL CROSS-SHADED EMERGENCY FIXTURES SHALL BE SWITCHED WITH THE REMAINING LAMPS OF THE FIXTURE. ON LOSS OF NORMAL
POWER, THE BATTERY BALLAST OF THE EMERGENCY FIXTURE SHALL AUTOMATICALLY ILLUMINATE THE EMERGENCY LAMP REGARDLESS OF
THE POSITION OF THE LIGHTING CONTROL SWITCH. ALL CIRCUITS SHALL BE CONNECTED TO THE CIRCUIT INDICATED, U.O.N.
ELECTRICAL EQUIPMENT SHOWN ON THE DRAWING HAS BEEN SELECTED BASED ON DIMENSION TO FIT THE SPACE. THE CONTRACTOR SHALL
VERIFY SUCH WITH PROPOSED EQUIPMENT DIMENSIONS PRIOR TO ORDERING OF THE EQUIPMENT.
MANUFACTURER'S RECOMMENDATIONS FOR CONDUCTOR SIZING, CIRCUIT BREAKER OR FUSE PROTECTION OF ELECTRICALLY OPERATED
EQUIPMENT MAY DIFFER FROM THOSE INDICATED ON DRAWINGS. CONTRACTOR SHALL CONFIRM RATINGS, PRIOR TO ORDERING EQUIPMENT.
PROVIDE ELECTRICAL PROTECTION TO EQUIPMENT PER MANUFACTURER'S SPECIFICATIONS. WHERE THE MECHANICAL EQUIPMENT
NAMEPLATE CIRCUIT REQUIREMENTS DIFFER FROM THE SPECIFIED EQUIPMENT, THE CIRCUIT BREAKERS, DISCONNECTS, AND WIRING SHALL
BE REVISED ACCORDINGLY. REVISIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO INSTALLATION.
FUSE SIZE FOR MECHANICAL EQUIPMENT DISCONNECT SWITCHES SHALL NOT BE GREATER THAN THE EQUIPMENT'S NAMEPLATE MOCP OR
MAXIMUM FUSE SPECIFICATION. DISCONNECT SWITCHES SHALL BE INSTALLED WITH CLEARANCES PER NEC.
CONTRACTOR SHALL REVIEW THE COMPLETE SET OF DOCUMENTS AND PROVIDE CONNECTION TO ALL ELECTRICALLY OPERATED EQUIPMENT
INDICATED, EVEN IF NOT SHOWN ON THE ELECTRICAL PLANS, UNLESS OTHERWISE NOTED. COORDINATE THE LOCATION AND ELECTRICAL
CONNECTION REQUIREMENTS PRIOR TO ORDERING OR INSTALLATION OF ELECTRICAL EQUIPMENT.
SUSPENDED, CEILING MOUNTED, ELECTRICAL EQUIPMENT SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE NOT FROM THE CEILING.
COORDINATE EXACT LOCATIONS OF ALL DEVICES, SWITCHES, RECEPTACLES, BOXES, COMM. OUTLETS, ETC. WITH OWNER/ARCHITECT PRIOR
TO ROUGH-IN.
CONNECTION TO ANY ROOF MOUNTED EQUIPMENT SHALL BE MADE ONLY THRU THE EQUIPMENT BASE. NO ADDITIONAL ROOF PENETRATIONS
SHALL BE MADE.
JUNCTION AND OUTLET BOXES SHALL BE SIZED IN ACCORDANCE WITH NEC SECTION 314. MINIMUM SIZE FOR JUNCTION BOXES SHALL BE
4"SQ. X 2-1/8"D. BOXES LARGER THAN MINIMUM SIZE WILL BE REQUIRED AT SOME LOCATIONS.
CIRCUITING AND HOMERUN CONDUITS SHALL BE INSTALLED AS INDICATED ON THE ELECTRICAL PLANS. DO NOT CHANGE CIRCUIT NUMBERS
WITHOUT PRIOR APPROVAL FROM ENGINEER. WHERE HOMERUNS ARE SHOWN AS A SINGLE HOMERUN FOR LIGHTS OR RECEPTACLE
CIRCUITS, CONTRACTOR SHOULD GROUP A MAXIMUM OF THREE CIRCUITS OR 6-CURRENT CARRYING CONDUCTORS PER HOMERUN TO
CONSERVE CONDUIT SPACE AT PANEL.
JUNCTION AND PULLBOXES SHALL ONLY BE LOCATED IN ACCESSIBLE CEILING AREAS. COORDINATE WITH ARCHITECTURAL RCP PRIOR TO
ROUGH-IN.
PROVIDE DETECTABLE WARNING TAPE 12" BFG FOR UNDERGROUND CONDUITS AND BURIED GROUNDING CONDUCTORS.
ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED WALLS AND FLOORS SHALL BE SEALED FOR MAINTAINING THE RATING OF THE
ASSEMBLY. DO NOT INSTALL FLUSH MOUNTED BOXES BACK-TO-BACK IN WALLS, OFFSET BOXES IN ADJACENT STUD CAVITIES. MAINTAIN AT
LEAST A 24 INCH SEPARATION IN FIRE-RATED WALLS. SEE ARCHITECTURAL DRAWINGS FOR LOCATION OF FIRE-RATED WALLS.
TERMINATION OF PHASE, NEUTRAL, AND GROUNDING CONDUCTORS SHALL BE MADE TO INDIVIDUAL TERMINALS/LUGS AT PANELS,
DISCONNECTS, DEVICES, ETC., UNLESS MULTIPLE CONDUCTOR TERMINATIONS ARE SPECIFICALLY ALLOWED BY THE MANUFACTURER.
WHERE MULTIPLE CONDUCTOR TERMINATIONS ARE ALLOWED, THE TERMINATIONS SHALL BE MADE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
FOR EACH NEW ELECTRICAL PANEL, PROVIDE A TYPED WRITTEN CIRCUIT DIRECTORY INSTALLED ON INSIDE OF DOOR, INDICATING THE AREA
AND LOADS SERVED BY EACH CIRCUIT. CIRCUIT DIRECTORY DESCRIPTIONS SHALL INCLUDE THE SPECIFIC NAMES AND/OR NUMBERS FOR
SPACES, WORKSTATIONS, ETC. AS COORDINATED WITH THE OWNER.
OUTLET BOXES FOR CATV OUTLETS SHALL BE MINIMUM 3.5" DEEP. CONDUIT SHALL ENTER NEAR BACK OF BOX.
ALL CIRCUITS SHALL INCLUDE AN EQUIPMENT GROUND CONDUCTOR IN THE RACEWAY.
NEW CIRCUIT BREAKERS FOR EXISTING PANELS SHALL BE BY THE PANELBOARD MANUFACTURER AND UL-LISTED FOR THE USE WITH AN AIC
RATING EQUAL TO THE EXISTING BREAKERS. CIRCUIT BREAKERS SERVING HVAC EQUIPMENT SHALL BE TYPE HACR.
PROVIDE SQUARE RECESSED J-BOX WITH 1.5" KNOCKOUT WITH SINGLE GANG TRIM AND 1
1
2
"C ELBOWED INTO ACCESSIBLE CEILING SPACE
FOR ALL COMMUNICATION & TELEVISION OUTLETS SHOWN. PROVIDE COMPRESSION CONDUIT CONNECTOR ON CONDUIT END, PLASTIC
SCREW ON BUSHING, AND PULLSTRING. COMMUNICATION WIRING BY OTHERS.
FIRE ALARM SYSTEM WORK SHALL BE BY A FIRE ALARM CONTRACTOR LICENSED FOR WORK IN THE STATE OF THE PROJECT. ALL FIRE ALARM
WIRING SHALL BE RUN IN CONDUIT.
WHEN DUCT SMOKE DETECTORS ARE REQUIRED AND NO FIRE ALARM SYSTEM IS INSTALLED, PROVIDE AN ANNUNCIATOR WITH POWER AND
ALARM LEDS EQUAL TO SYSTEM SENSOR MODEL# APA151.
FINAL QUANTITY AND LOCATION OF FIRE ALARM DEVICES SHALL BE IN ACCORDANCE WITH NFPA-72, TAS, MANUFACTURER'S REQUIREMENTS,
NFPA-101, IBC, AND ANY ADDITIONAL LOCAL GOVERNING CODES.
THE FIRE ALARM CONTRACTOR IS RESPONSIBLE TO DESIGN AND PROVIDE A COMPLETE FIRE ALARM SYSTEM, PER SPECIFICATIONS.
THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR THOROUGHLY REVIEWING THE COMPLETE SET OF PLANS AND SPECIFICATIONS TO
ASCERTAIN/VERIFY REQUIRED DEVICE LOCATIONS.
PRIOR TO BID, THE CONTRACTOR SHALL VISIT THE SITE TO ASCERTAIN REQUIREMENTS FOR INTERFACING THE NEW FIRE ALARM SYSTEM
WITH THE EXISTING.
INSTALL SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72 AND THE MANUFACTURER'S INSTRUCTIONS. MAINTAIN A MINIMUM CLEAR
DISTANCE OF 4 INCHES FROM WALLS, LIGHT FIXTURES, AND OTHER OBJECTS AND 12 INCHES FROM FLUORESCENT FIXTURES. DETECTORS
SHALL NOT BE INSTALLED WITHIN 3 FEET OF HVAC SUPPLY DIFFUSERS OR IN THE DIRECT AIR FLOW OF HVAC SUPPLY DIFFUSERS. CONNECT
DETECTORS AHEAD OF LIGHT SWITCHES WHERE SHOWN TO BE CONNECTED TO LIGHTING CIRCUITS.
ANY ACCESS CONTROL MAG LOCKS SHALL BE FACE MOUNTED TO THE DOOR FRAME SO AS NOT TO REDUCE THE CLEAR HEADROOM OF THE
DOORWAY.
ONLY UTILITIES AND SYSTEMS SERVING THE ELEVATOR EQUIPMENT SHALL BE ALLOWED TO ENTER AN ELEVATOR ROOM. NO OTHER UTILITY
SHALL ENTER OR PASS THROUGH.
ABBREVIATIONSGENERAL NOTES
E
POWER DISTRIBUTION HANDHOLE OR MANHOLE, SIZE AS INDICATED
T
TELECOMMUNICATIONS HANDHOLE OR MANHOLE, SIZE AS INDICATED
TELEPHONE SYSTEM - TERMINAL BACKBOARD (TTB)
WALL SWITCH--20AMP, 120/277V., 3-WAY
CIRCUIT RISER DOWN
3
WALL SWITCH--20AMP, 120/277V, DIMMING
FLEXIBLE CONDUIT CONNECTION
CIRCUIT RISER UP
D
HOMERUN TO PANEL (CIRCUIT NUMBERS INDICATED)
CIRCUIT CONCEALED BELOW GRADE OR FLOOR
(#12 AWG UNLESS NOTED OTHERWISE OR REQUIRED)
"X"
GFI
CEILING MOUNTED DOUBLE-HEAD EMERGENCY LIGHT
CODE SIZE JUNCTION BOX-SIZE AS NOTED OR REQ'D
METER BASE AND METER
DISCONNECT SWITCH, NON FUSIBLE
WELDING RECEPTACLES, 480V, 60A, 3O, 3W
MOTOR CONNECTIONS, SIZE AS SCHEDULED
DISTRIBUTION OR PAD MOUNTED TRANSFORMER
NEMA 5-20R
A:1,3
GROUNDING ELECTRODE CONNECTION
COPPER WELD GROUND ROD AND INSPECTION WELL
PANELBOARD REFER TO SCHEDULE.
ELECTRIC VENT FAN
DISCONNECT SWITCH, FUSIBLE
V
F
FLOOR OUTLET - DUPLEX RECEPTACLE
WALL OUTLET--DOUBLE DUPLEX RECEPTACLE,
MOUNTED ABOVE COUNTER, NEMA 5-20R
WALL OUTLET--DUPLEX RECEPTACLE, FLUSH
WALL OUTLET--DUPLEX RECEPTACLE, FLUSH
MOUNTED UNDER COUNTER, NEMA 5-20R
WP
FLUSH MOUNTED, NEMA 5-20R
M
DESCRIPTIONSYMBOL
TO FIXTURE SCHEDULE. "X" EQUAL FIXTURE MARK
WALL BRACKET - FLUORESCENT LUMINAIRE REFER
WALL SWITCH--20AMP, 120/277V, SPST
NUMBER OF CURRENT CARRYING, INTEGER INDICATES
ELECTRICAL KEYED NOTE REFERENCE
MOTOR RATED WALL SWITCH--20AMP, 120/277V, WITH
M
INTEGRAL THERMAL OVERLOAD
FIRE ALARM CONTROL PANEL
MASS NOTIFICATION SYSTEM CONTROL PANEL
3/4"x10'-0" UON
COMBINATION MAGNETIC MOTOR STARTER WITH FUSIBLE
2
DISCONNECT SWITCH; INTEGER INDICATES NEMA SIZE
PULL BOX WITH HINGED COVER, SIZE AS INDICATED
LUMINAIRE WITH INTEGRAL EMERGENCY POWER PACK
CEILING MOUNTED OCCUPANCY SENSOR W/INTEGRAL POWER PACK
FA
POWER SUPPLY; "FA" INDICATES FIRE ALARM, "D" INDICATES DIMMER
SPRINKLER FLOW OR PRESSURE SWITCH
FIRE ALARM SYSTEM - HVAC DUCT SMOKE DETECTOR
#10
CONDUCTOR SIZE
SWITCHBOARD OR DISTRIBUTION PANEL
DESCRIPTIONSYMBOL
2a
TIMECLOCK
PHOTOELECTRIC CELL
PE
LIGHTING RELAY CONTROL PANEL
STSHUNT TRIP COIL
F
CABLE TRAY, SIZES AS INDICATED
MASS NOTIFICATION SYSTEM - NOTIFICATION DEVICE
MULTI-OUTLET ASSEMBLY W/REC @ 12" OC
DOOR CONTROLLER FOR ACCESS CONTROL SYSTEM
KEY PAD FOR ACCESS CONTROL SYSTEM
POWER POLE
O/H
EXISTING OVERHEAD LINE
T
TELECOMMUNICATIONS UNDERGROUND CONDUIT OR DUCT BANK
EXISTING UNDERGROUND CONDUIT OR DUCT BANK
NEW UNDERGROUND CONDUIT OR DUCT BANK
CEILING FAN CONNECTION
F
abc
WALL SWITCH--20AMP, SPST. "a,b,c..." INDICATES
CONTROLLING SWITCH. NUMBER OF LETTERS
CORRESPONDS TO NUMBER OF SWITCHES REQUIRED
FIRE ALARM MANUAL PULL STATION
INTERCOM CALL-IN STATION
INTERCOM/PA SYSTEM - CEILING SPEAKER
INTERCOM/PAGING EXTERIOR, WEATHERPROOF,
HORN/SPEAKER
PROGRAM CLOCK. SUBSCRIPT "2" INDICATES TWO FACES
TWO GANG RECESSED BOX WITH 1"C INTO ACCESSIBLE
CEILING SPACE FOR TV SIGNAL
2
WP
WALL SWITCH--20AMP, 120/277V, KEY OPERATED
k
"X"
"X"
"X"
NOTE: ALL SYMBOLS MAY NOT BE USED
PB
PROGRAM BELL
LV
WALL SWITCH--LOW VOLTAGE W/MOMENTARY CONTACT
LIGHTING CONTACTOR
DOOR HOLD OPEN DEVICE - INTERLOCK WITH FIRE
ALARM TO RELEASE ON ALARM CONDITION
SECURITY CAMERA
COMM FLOOR OUTLET - VOICE/DATA
SINGLE GANG RECESSED BOX WITH 3/4"C INTO ACCESSIBLE
CEILING SPACE FOR SOUND SYSTEM
RECESSED BOX WITH 1"C INTO ACCESSIBLE CEILING SPACE
FOR VIDEO
RECESSED FLOOR BOX WITH 1"C INTO ACCESSIBLE CEILING FOR
VIDEO
RESCUE ASSISTANCE CALL STATION
RESCUE ASSISTANCE ANNUNCIATOR PANEL
COMM OUTLET, - DATA ONLY, RECESSED IN WALL, UON
SPRINKLER TAMPER SWITCH
FIRE ALARM SMOKE DETECTOR
FIRE ALARM HEAT DETECTOR. 195 INDICATES 195 DEGREE DETECTOR
SPRINKLER SYSTEM - DRY PIPE AIR COMP PRESSURE SWITCH
OS
WALL SWITCH--20AMP, 120/277V WITH OCCUPANCY SENSOR CONTROL
M
MASS NOTIFICATION SYSTEM - CEILING MOUNTED NOTIFICATION DEVICE
EXIT SIGN FIXTURE - DIRECTIONAL ARROWS AS INDICATED
SINGLE MONITOR MODULE
RELAY MODULE
195°
FIRE/SECURITY SYSTEM KEYPAD
SECURITY SYSTEM DOOR CONTACT
SECURITY PANEL
MS
SECURITY SYSTEM MOTION SENSOR. "LR" INDICATES LONG RANGE.
LR
DUAL MONITOR MODULE
FIRE ALARM REMOTE ANNUNCIATOR
FIRE ALARM COMBINATION HORN/STROBE - CEILING MOUNTED;
SUBSCRIPT=CANDELA RATING
30
30
FIRE ALARM COMBINATION HORN/STROBE - SEMI-FLUSH MOUNTED
UON, 6'-8"AFF TO BOTTOM OF STROBE UON
SUBSCRIPT=CANDELA RATING
30
30
FIRE ALARM STROBE - CEILING MOUNTED
SUBSCRIPT=CANDELA RATING
FIRE ALARM STROBE - SEMI-FLUSH WALL MOUNTED UON, 6'-8"AFF TO
BOTTOM UON; SUBSCRIPT=CANDELA RATING
CEILING OUTLET - FLUORESCENT LUMINAIRE REFER TO
FIXTURE SCHEDULE. "X" EQUAL FIXTURE MARK, "2" EQUAL BR
CKT DESIGNATION, "a" INDICATED CONTROLLING SWITCH LEG
E
GFI
"X"
J
J
J
J
J J
TV
S
V
V
X
T
OS
S
3 POLE WALL OUTLET "X" INDICATES NEMA CONFIGURATION;
COORDINATE WITH EQUIP. SUPPLIER FOR RECEPT. CONFIG. REQUIRED
CEILING OUTLET, DUPLEX RECEPTACLE, FLUSH MOUNTED,
NEMA 5-20R
FLUORESCENT STRIP FIXTURE, REFER TO FIXTURE
SCHEDULE; "X" EQUAL FIXTURE MARK
WALL BRACKET - REFER TO FIXTURE SCHEDULE;
"X" EQUAL FIXTURE MARK
CONDUIT CONCEALED IN WALL OR OVERHEAD
(#12 AWG UNLESS NOTED OTHERWISE OR REQUIRED)
ELECTRICAL LEGEND
SURFACE METAL RACEWAY, OR WIREWAY, SIZE AS INDICATED WITH
W
RECEPTACLES AS SHOWN.
WALL OUTLET--DUPLEX RECEPTACLE,
FLUSH MOUNTED, NEMA 5-20R
WALL OUTLET--DUPLEX OUTLET, WITH GROUND FAULT
INTERRUPTING FEATURE
WALL OUTLET--DUPLEX OUTLET, WITH GROUND FAULT INTERRUPTING
FEATURE. WP INDICATES WEATHERPROOF COVER PROVIDED
SHORT SLASHES = PHASE OR SWITCHED CONDUCTORS, LONG SLASHES =
NEUTRAL CONDUCTORS, NO SLASHES=2#12,1#12G-3/4"C, U.O.N.
PB
H
RAAP
S
I
PS
TS
FS
RM
DM
SM
CS
PS
MNS
LCP
LC
TC
FACP
FARA
DCP
SEC
DC
KP
M
COMM OUTLET, - VOICE & DATA, RECESSED IN WALL, UON. WHERE
COMM OUTLET, - VOICE ONLY, RECESSED IN WALL, UON. WHERE
SUBSCRIPT "AC" SHOWN INDICATES ABOVE COUNTER.
SUBSCRIPT "W" SHOWN INDICATES WALL MOUNTED.
AC
W
ELEV
102
RESOURCE
100
BANKER POD
109
LOUNGE
110
C
FE
1
A
B
D
E
F
EXISTING STAIR
103
JANITOR
104
TOILET
105
CONFERENCE
106
CORRIDOR
107
VAULT
111
WET BAR
101
BRANCH MANAGER
108
STAIR
112
MECH
113
1A 2 31 3A
F
S
S
S
S
1
S
1
S
1
OS
3
SN
SA1
SA
SA
SQ SQ
SA
SA
SA
SA
SA
SA
SM1
SM2
SH
SH
DF1
SA
SA
DF1
SS
DF2
SF
SF
SF
SDSD
SD SD
SE2
SE1
SE1
SE3
SP3SP2 SP1
ST
SB2
SB1
SG1 SCSC
SC
SC
SA SA SA
2
2
2
S
X
X
S
M:1
SE4
SJ
ST
ST
7
5
7
7
5
5
S
SK
SK
B
A
8
W
M:7
STAIR LANDING
202
CATERING
205
ELEV
201
MECH/ IT
203
TOILET
204
CORR
206
CORR
202
C
A
D
E
F
FE1
GALLERY
200
1A
B
21B 31 3A
DN
S
1
S1
S
OS
4
S
S
SM3
SM4
SA
SH
SH
SA
SA
SA
SA
SA
SA
SQ
SQ
OS
3
SO SO SO
SO SO SO
SO SO SO
SO SO SO
SO SO SO
SO SO SO
SO SO SO
SO SO SO
SR SR SR SR SR SR SR SR SR SR SR
2
2
SG2
SJ
X
X
5
7
7
5
SL
SL
5
5
5
5
5
7
5
6
C
x3
8
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
09/11/17
JOB NUMBER
SHEET NUMBER
16.093
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
DO
WN
TO
WN
B
RA
NC
H
TY
LE
R, T
EX
AS
SHEET REVISION HISTORY
PROJECT MANAGER
PAIGE ENGEL
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROBBIN K. CASSITY, P.E.
84344
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-022
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0"LIGHTING PLANS
E201
1. LUTRON KEY PAD WITH OCCUPANCY SENSOR.
COORDINATE WITH LIGHTING DESIGNER FOR NUMBER OF
BUTTONS NECESSARY FOR EACH ROOMS LIGHTS.
2. LUTRON KEY PAD. COORDINATE WITH LIGHTING
DESIGNER FOR NUMBER OF BUTTONS NECESSARY FOR
EACH ROOMS LIGHTS.
3. DUAL TECHNOLOGY, SELF ADAPTIVE, CEILING MOUNTED
OCCUPANCY SENSOR EQUAL TO LUTRON LOS-CDT-500-WH.
PROVIDE POWER PACK(S) AS REQUIRED FOR LIGHTING
LOAD CONTROLLED. EXACT QUANTITY AND LOCATION OF
SENSORS AS PER MANUFACTURER'S RECOMMENDATION.
4. PASSIVE INFRARED, SELF ADAPTIVE, CEILING MOUNTED
OCCUPANCY SENSOR EQUAL TO LUTRON LOS-CIR-1500-WH.
PROVIDE POWER PACK(S) AS REQUIRED FOR LIGHTING
LOAD CONTROLLED.
5. THESE FIXTURES SHALL BE CONNECTED TO THE
INVERTER (REF. KEY NOTE 6) FOR EMERGENCY POWER IN
ADDITION TO BEING CONNECTED TO THE RELAY PANEL.
6. INVERTER EQUAL TO DUAL LITE MODEL
DLS-2100-120-.A2010. INVERTER TO SERVE RELAY CIRCUITS
L:1,17,25,26,37,44,46,53,55,57. PROVIDE ATSD20 IF
NECESSARY FOR PROPER FUNCTION OF INVERTER
SYSTEM.
7. SELECT THIS FIXTURE WITH EMERGENCY BATTERY
OPTION. VERIFY EMERGENCY TEST SWITCH INTEGRAL TO
FIXTURE. IF NOT CONTACT ENGINEER.
8. CONNECT LIGHTS IN THE MECHANICAL ROOM TO CIRCUIT
M:9.
NOTE:
REF. LIGHTING DESIGNERS PLANS, SHEET LD1.00
AND LD1.01 FOR LIGHTING CIRCUITING. IN THE
EVENT OF CONFLICTS BETWEEN THESE DRAWINGS
AND THE LIGHTING DESIGNERS PLANS, THE
LIGHTING DESIGNERS PLANS TAKE PRECEDENCE.
NOTE:
RELAY PANEL SERVING LIGHTS MUST BE CIRCUIT
BREAKER TYPE, NOT FEED THRU TYPE.
ELEV
102
RESOURCE
100
BANKER POD
109
LOUNGE
110
C
FE
1
A
B
D
E
F
EXISTING STAIR
103
JANITOR
104
TOILET
105
CONFERENCE
106
CORRIDOR
107
VAULT
111
WET BAR
101
BRANCH MANAGER
108
STAIR
112
MECH
113
1A 2 31 3A
F
1
2
CU
CU
(DUCTLESS)
EF-2
EF-1
V
S
V
S7
8
9
J
J
10
J
10
J
10
J
10
J
10
J
10
J
10
CU-1
M:2
M:4
M:6
M:12
M:8
M:16
M:18
M:20
M:22
M:24
M:26M:28
M:30
M:32
M:34
30AS-3P
20AF
NEMA 3R
WH
7
M:10
1
FIRE ALARM
ANNUNCIATOR PANEL
14
H:2/4/6
30AS-2P
NEMA 1
H:7/9
S15
M:3
M:5
16
J
J
18
STAIR LANDING
202
CATERING
205
ELEV
201
MECH/ IT
203
TOILET
204
CORR
206
CORR
202
C
A
D
E
F
FE1
GALLERY
200
1A
B
21B 31 3A
DN
EXISTING PANEL "M"
EXISTING WALL MOUNTED AHU (DUCTLESS)
EF-3V
S
100AS-3P
70AF
NEMA 1
4 5
6
3 5
7
J
10
J
10
AHU-1
FUR
<E>
M:27
M:19
M:17
M:15
FIRE ALARM
CONTROL PANEL
M:35
M:36
M:38
11
12
13
M:21
M:23
M:25
NEW PANEL "H"
NEW XFMR "T-M"
T
H:1/3/5
60AS-3P
40AF
NEMA 1
M:40
H:37/39/41
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
09/11/17
JOB NUMBER
SHEET NUMBER
16.093
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
DO
WN
TO
WN
B
RA
NC
H
TY
LE
R, T
EX
AS
SHEET REVISION HISTORY
PROJECT MANAGER
PAIGE ENGEL
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROBBIN K. CASSITY, P.E.
84344
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-022
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0"POWER & SYSTEMS
PLANS
E301
1. COORDINATE MOUNTING HEIGHT OF POWER/DATA
OUTLETS FOR MONITOR WITH ARCHITECT PRIOR TO
ROUGH-IN.
2. CABLE TRAY TO BE MOUNTED JUST ABOVE CPU SHELF.
REF. ARCHITECTURAL DETAIL C4 SHEET A703.
3. PROVIDE ENCLOSED CIRCUIT BREAKER DISCONNECTING
MEANS IN NEMA 1 ENCLOSURE FOR POWER TO ELEVATOR
CAR LIGHTS, RECEPTACLES AND VENTILATION.
4. PROVIDE ENCLOSED SHUNT TRIP CIRCUIT BREAKER OR
FUSED DISCONNECTING MEANS IN NEMA 1 ENCLOSURE.
PROVIDE SUPERVISED INTERLOCK WITH FIRE ALARM
SYSTEM IAW REQUIREMENTS OF ASME A17.1 AND NEC
620.51. SHUNT TRIP POWER FROM EXISTING PANEL "M"
REFERENCE DETAIL A, SHT. E401.
5. COORDINATE EXACT LOCATIONS OF DISCONNECTS AND
SUPPLY EQUIPMENT WITH ELEVATOR EQUIPMENT
ARRANGEMENT.
6. VERIFY EXACT SIZE AND ARRANGEMENT OF ELEVATOR
DISCONNECTS WITH EQUIPMENT MANUFACTURERS
REQUIREMENTS PRIOR TO ROUGH-IN.
7. CONNECT EXHAUST FAN TO RESTROOM LIGHTS. FAN TO
RUN WITH LIGHTS ON.
8. MOUNT RECEPTACLE IN CABINET AT 26"AFF.
9. PROVIDE (2) CAT6 OUTLETS AT THIS LOCATION FOR
CONNECTION TO ITM. COORDINATE WITH ITM SUPPLIER.
10. J-BOX FOR CAMERA.
11. DEDICATED RECEPTACLE FOR SERVER RACKS. VERIFY
LOCATION WITH IT PERSONNEL PRIOR TO ROUGH-IN.
12. PROVIDE (2) 2"C STUBBED AT LOCATION OF SERVER
RACK AND EXTENDED TO PHONE PEDESTAL AS PER PHONE
COMPANY REQUIREMENTS FOR PHONE/DATA/CATV
SERVICE. CONFIRM CONDUIT TO UTILITY PEDESTAL
UNDERGROUND AND NOT OVERHEAD TO INTERFACE BOX
ON BLDG.
13. DEDICATED RECEPTACLE ABOVE DOOR FOR POWER TO
SECURITY SYSTEM. VERIFY LOCATION WITH SECURITY
PROVIDER PRIOR TO ROUGH-IN.
14. SERVICE DISCONNECT AND METER. REF. RISER
DIAGRAM.
15. MOTOR RATED TOGGLE SWITCH FOR SUMP PUMP IN
ELEVATOR PIT.
16. MOUNT TO BOTTOM OF NEAREST CEILING JOIST.
17. J-BOX FOR POWER TO WALL MOUNTED SIGN.
COORDINATE HEIGHT WITH ARCHITECT PRIOR TO
ROUGH-IN.
18. PHONE LINE FOR ELEVATOR. VERIFY EXACT LOCATION
WITH MANUFACTURE PRIOR TO ROUGH-IN.
NOTE:
ALL DATA CONDUITS FOR TVS SHALL BE 2".
ALL OTHER DATA CONDUITS SHALL BE 1.5". CONTRACTOR
SHALL PROVIDE J-BOXES SIZED PER NEC TO HANDLE
THESE LARGER CONDUITS. PRIOR TO ORDERING, VERIFY
WITH OWNER THAT THE LARGER BOXES ARE ACCEPTABLE.
NOTE:
PLENUM RATED CABLES SHALL BE USED
IN ALL PLENUM AREAS.
NOTE:
FLOOR BOX OUTLETS SHALL HAVE
STAINLESS STEEL COVER PLATES.
NOTE:
UNDERGROUND CONDUITS SHALL BE ROUTED
TO NEAREST NEW WALL FOR STUB UP TO
SECOND FLOOR PANEL LOCATION.
©
5201 S. Broadway Avenue,
Suite 200
Tyler, Texas 75703
903.592.0728
903.595.0369 fax
info@fitzpatrickarchitects.com
09/11/17
JOB NUMBER
SHEET NUMBER
16.093
DATE
E
D
C
B
A
1 2 3 4 5 6
SO
UT
HS
ID
E B
AN
K
DO
WN
TO
WN
B
RA
NC
H
TY
LE
R, T
EX
AS
SHEET REVISION HISTORY
PROJECT MANAGER
PAIGE ENGEL
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
ROBBIN K. CASSITY, P.E.
84344
THESE DRAWINGS DO NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY.
17-022
ENGINEER:
LICENSE NO.
CONSULTING ENGINEERS
FIRM REGISTRATION NO. 667
3003 KNIGHT STREET, SUITE 120
SHREVEPORT, LOUISIANA 71105
phone: 318-425-7452 fax: 318-425-4622
www.AFJMc.com
COPYRIGHT NOTICE:
THIS ENGINEERING DRAWING SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH AFJMC. NO
OTHER USE DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF AFJMC.
ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
ELECTRICAL DETAILS
E401
CR1
120 VAC CONTROL
POWER TO TRIP
SUPERVISED ELEV
POWER CIRCUIT FROM
FIRE ALARM SYSTEM
CR2
TO FIRE ALARM
DEVICE CIRCUIT
NEMA 1
ENCLOSURE
ELEV POWER
CIRCUIT BREAKER
DISCONNECT
SUPERVISED
SIGNAL TO
FACP
CR2 CR1
ST
WALL MOUNTED ADJUSTABLE FIXTURE
SURFACE MOUNTED ADJUSTABLE FIXTURE
RECESSED ADJUSTABLE FIXTURE (ROUND)
RECESSED FIXTURE (ROUND)
RECESSED WALL WASHER
SURFACE MOUNTED FIXTURE
WALL SCONCE
PENDANT OR CHANDELIER
LINEAR LIGHTING (VERTICAL)
TRACK FIXTURE
DIMMED FLOOR RECEPTACLE (NEMA 6-20R NOTE 2)
DIMMED DUPLEX RECEPTACLE (NEMA 6-20R,NOTE2)
DIMMED SIMPLEX RECEPTACLE (NEMA 6-20R,NOTE2)
CLOCK RECEPTACLE
LIGHTING LEGEND
RECESSED ADJUSTABLE FIXTURE (SQUARE)
LINEAR LIGHTING (HORIZONTAL)
RECESSED FIXTURE (SQUARE)
FESTOON LIGHTING (HORIZONTAL)
RECESSED FLUORESCENT FIXTURE
SURFACE MOUNTED WALL WASHER
FLOOR LAMP
TABLE LAMP
FIXED STEPLIGHT
DIRECTIONAL STEPLIGHT
GRAFIK EYE CONTROL
DOOR JAMB SWITCH (SPST)
DIMMER
KEYPAD
J BOX
POWER SUPPLY
PARKING LOT POLE
PEDESTRIAN POLE
PARKING LOT POLE
TRANSFORMER
RGB CONTROLLER
OCCUPANCY SENSOR
SHEET NUMBER:
REVISION
LD0.00
LEGEND &
SCHEDULES
SCOTT OLDNER LIGHTING DESIGN
t 214-414-1030 f 214-414-1026
5331 E. MOCKINGBIRD LANE
SUITE 304
DALLAS, TX 75206
SHEET TITLE:
Co
pyrig
ht (c) b
y S
co
tt O
ld
ne
r L
ig
htin
g D
esig
n, In
c. A
ll R
ig
hts R
ese
rve
d.
SCALE
PR
OJE
CT
N
AM
E &
LO
CA
TIO
N
DATE
ISSUE
SCHEMATIC
DESIGN
Date Descriptionxxxxxx1
3 AUGUST 2017
DA
LL
AS
, T
X
SO
UT
HS
ID
E B
AN
K D
OW
NT
OW
N
08/09/2017
ELEV
102
RESOURCE
100
BANKER POD
109
LOUNGE
110
10
71
07
104
111
BA
11
0
C
106
105
FE
1
EXISTING STAIR
103
JANITOR
104
TOILET
105
CONFERENCE
106
CORRIDOR
107
VAULT
111
WET BAR
101
BRANCH MANAGER
108
STAIR
112
MECH
113
103
11
2
ELEV
102
RESOURCE
100
BANKER POD
109
LOUNGE
110
EXISTING STAIR
103
JANITOR
104
TOILET
105
CONFERENCE
106
CORRIDOR
107
VAULT
111
WET BAR
101
BRANCH MANAGER
108
STAIR
112
MECH
113
SA SA
SB1
SC
SG1
SCSC SC
SA
SB2
SK
SDSDSDSD
SK
SF
SE1 SE3SE1 SE1
SE2
DF2 SF
SF
SS
SJ
SA
SA
SA
SH
SH
ST
ST
ST
DF1
SP3 SP2 SP1
SE4SM2SM1
SA
SQ SQ
SA
SA
SA
SA
SA
DF1
SA1
SN
ART
SA
L 24
L 21
L 20
L 22
L 19
L 18
L 12
L 13
L 15L 14
L 9
L 11
L 8
L 10
L 5 L 6
L 1
L 7
L 2
L 4
L 3L 23
L 16
L 17
SHEET NUMBER:
REVISION
LD1.00
1ST FLOOR
INTERIOR
LIGHTING PLAN
SCOTT OLDNER LIGHTING DESIGN
t 214-414-1030 f 214-414-1026
5331 E. MOCKINGBIRD LANE
SUITE 304
DALLAS, TX 75206
SHEET TITLE:
Co
pyrig
ht (c) b
y S
co
tt O
ld
ne
r L
ig
htin
g D
esig
n, In
c. A
ll R
ig
hts R
ese
rve
d.
SCALE
PR
OJE
CT
N
AM
E &
LO
CA
TIO
N
DATE
ISSUE
3 AUGUST 2017
1/4" - 1'-0"
SCALE: 1/4" = 1'-0" 01 1ST FLOOR INTERIOR LIGHTING PLAN
SCHEMATIC
DESIGN
Date Descriptionxxxxxx1
DA
LL
AS
, T
X
SO
UT
HS
ID
E B
AN
K D
OW
NT
OW
N
08/09/2017
C C
AA
D D
E E
F F
EXISTING WOOD JOISTS
±11'-4" AFF (FV)
PT?
AC1
+9'-0"
EXPOSED
CBF SOFFIT
+18'-0" A.F.F @
STAIR LANDING
202
EXPOSED
1A
1A
B B
2
21B
3
3
1
1
3A
3A
5 47 6
±1'-10" 4'-0" 4'-0" 4'-0" 4'-0" ±1'-10"
1'-7
"
C3
A302
D5
A302
A5
A605
C3
A605
A3
A605
PT1+9'-0"
EXISTING WOOD JOISTS
±11'-4" AFF (FV)
PT_ +10'-8"A.F.F @GALLERY 200
AC1
+9'-0"
EXISTING
CEILING
PT4
AC1
+9'-0"
AC1
+10'-0"
PT_
+14'-10 1/2" A.F.F @
GALLERY 200
PT1 +7'-0"
STAIR LANDING
202
CATERING
205
ELEV
201
MECH/ IT
203
TOILET
204
CORR
206
CORR
202
D
204
20
5
203
206
FE1
GALLERY
200
EXISTING
CEILING
PT4
COVE LIGHTING
CONCEPT
EXPOSED
EXPOSED
EXISTING WOOD JOISTS
±11'-4" AFF (FV)
EXISTING WOOD JOISTS
±11'-4" AFF (FV)
PAINTED SW 7019
GAUNTLET GRAY
SL SL
SO
SO
SO
SO
SO
SO
SO
SO
SA
SQ SQ
SA
SH
SA
SA
SA
SA
SH
SJ
SM4SM3
SR SR SR SR SR SR SR SR SR SR
SG2
L 34 L 33 L 32
L 37 L 36 L 35
L 40 L 39 L 38
L 43 L 42 L 41
L 55 L 54 L 53
L 52 L 51 L 50
L 49 L 48 L 47
L 46 L 45 L 44
L 56
L 57
SA
L 31
L 30
L 28
L 27
L 25
L 26
L 29
L 59
L 58
SOT
SOT
SOT
SOT
SOT
SOT
SOT
SOT
SHEET NUMBER:
REVISION
LD1.01
2ND FLOOR
INTERIOR
LIGHTING PLAN
SCOTT OLDNER LIGHTING DESIGN
t 214-414-1030 f 214-414-1026
5331 E. MOCKINGBIRD LANE
SUITE 304
DALLAS, TX 75206
SHEET TITLE:
Co
pyrig
ht (c) b
y S
co
tt O
ld
ne
r L
ig
htin
g D
esig
n, In
c. A
ll R
ig
hts R
ese
rve
d.
SCALE
PR
OJE
CT
N
AM
E &
LO
CA
TIO
N
DATE
ISSUE
3 AUGUST 2017
1/4" - 1'-0"
SCALE: 1/4" = 1'-0" 01 2ND FLOOR INTERIOR LIGHTING PLAN
SCHEMATIC
DESIGN
Date Descriptionxxxxxx1
DA
LL
AS
, T
X
SO
UT
HS
ID
E B
AN
K D
OW
NT
OW
N
08/09/2017
19'-8"
3" 3'-9" 3" 3' 3" 4'-11" 3" 3' 3" 3'-9" 2"
3"
2'-11"
3"
3'
3"
4'-11"
3"
3'
3"
2'-11"
3"
CBF PANEL
RAINSCREEN
CURTAIN WALL
SYSTEM
GLAZED BRICK
PRE FIN MTLCOPING
BACKLIT
SIGNAGE, TBD
ALUM
STOREFRONT
SYSTEM
±0"
+9'-4"
+27'-4"
+33'-10"
4"
1'
1'
1'
1'
2'
2'
2'
3'
3'
3'
4'
4'
4'
±<
MeasuredV
alue>
18'
EQ4' 4' 4' 4'
EQ
3'
SB
SB2
SHEET NUMBER:
REVISION
LD2.00
ELEVATIONS
LIGHTING PLAN
SCOTT OLDNER LIGHTING DESIGN
t 214-414-1030 f 214-414-1026
5331 E. MOCKINGBIRD LANE
SUITE 304
DALLAS, TX 75206
SHEET TITLE:
Co
pyrig
ht (c) b
y S
co
tt O
ld
ne
r L
ig
htin
g D
esig
n, In
c. A
ll R
ig
hts R
ese
rve
d.
SCALE
PR
OJE
CT
N
AM
E &
LO
CA
TIO
N
DATE
ISSUE
1/4" - 1'-0"
SCALE: 1/4" = 1'-0" 01 LIGHTING ELEVATION
SCHEMATIC
DESIGN
Date Descriptionxxxxxx1
3 AUGUST 2017
DA
LL
AS
, T
X
SO
UT
HS
ID
E B
AN
K D
OW
NT
OW
N
08/09/2017
03 WALL GRAZE POCKET DETAIL
CONTINUE WALLFINISH INTO COVE
FINISH MATTE WHITE/ PER ID
CEILING LINE
LIGHT FIXTURE
2"
1'-0"
SCALE: 1-1/2" = 1'-0"
10"
UNDER SHELF LIGHTING DETAIL02
LIGHT FIXTURE
1 1 2"
SCALE: 1-1/2" = 1'-0"
OVER/UNDER CABINET LIGHTING DETAIL
ALIGN FIXTURE WITH TOP OF LIP
LIGHTING FIXTURE
PROVIDE BLOCKING AS REQUIRED
CABINET DETAIL BY OTHERS
LIGHTING FIXTURE
01
LIGHTING FIXTURE
2 1 2"
SCALE: 1-1/2" = 1'-0"
SHEET NUMBER:
REVISION
LD3.00
DETAIL LIGHTING
PLAN
SCOTT OLDNER LIGHTING DESIGN
t 214-414-1030 f 214-414-1026
5331 E. MOCKINGBIRD LANE
SUITE 304
DALLAS, TX 75206
SHEET TITLE:
Co
pyrig
ht (c) b
y S
co
tt O
ld
ne
r L
ig
htin
g D
esig
n, In
c. A
ll R
ig
hts R
ese
rve
d.
SCALE
PR
OJE
CT
N
AM
E &
LO
CA
TIO
N
DATE
ISSUE
1/4" - 1'-0"
SCHEMATIC
DESIGN
Date Descriptionxxxxxx08/09/20171
3 AUGUST 2017
DA
LL
AS
, T
X
SO
UT
HS
ID
E B
AN
K D
OW
NT
OW
N
top related