electric wiring kit for towbars / 7-pin / 12n / 12 volt ... · renault installation of the towing...

Post on 23-Mar-2020

2 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Part No. 19180525RCRENAULT

Installation of the towing electrics kit must be undertaken by a specialist workshop or an appropriately qualified person. Before starting work, you must read the installation instructions through completely. After installing the towing electrics kit, the installation instructions should be kept with the vehicle service documentation.

All claims under the guarantee will lapse in case of improper use or modification of the towing electrics kit or any of its component parts. When driving without a trailer or load carrier, any adapter installed must be removed from the electrical socket. We reserve the right to alter the design, content or colour. We accept no liability for any errors in these instructions. All details and illustrations are non-binding.

Fitting instructions

In case of missing a rear fog lamp on the trailer, it should be retrofitted.

We accept no responsibility and give no guarantee for technical and electrical modifications made after the initial operation of the towing electrics kit by the vehicle manufacturer and which may lead, for example to malfunction of the trailer socket or its peripheries.

The trailer module is not diagnostics-capable. If the manufacturer’s diagnostics processes or software-supported test mechanisms generate error reports directly or indirectly linked with trailer operation, the trailer module must be disconnected from the leads to the trailer socket and a new diagnostic process initiated.

Electric wiring kit for towbars / 7-pin / 12N / 12 Volt / ISO 1724

IMP

OR

TAN

T!

1/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

Grand Scenic 05/09Scenic 07/09

3x 10x 5x2x90270328

20A

14-17

9-134-5, 18-26,

29-35

36

20A

2/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

3x

In order to avoid mal-functions and damage to the vehicle’s electrical system the earth terminal must be disconnected from the vehicle’s battery before starting work!

Both the trailer module and the vehicle’s control unit for the electrical system can be damaged during work on the data bus connections if the battery is not disconnected!

Please pay attention to the manufacturer’s instructions when disconnecting and reconnecting the vehicle’s battery!

3/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

1

SYMBOL EXPLANATION

90500760

MANUAL

IMPORTANT!

+ -

15+

+-

30+

Reverse

B+/30

20A

left (58-L) respectively right (58-R) tail light

stop light (54) / high mounted, third stop light (54)

turn signal indicator left

turn signal indicator right

rear fog light(s)

reversing light(s)

Permanent power supply / 13pin socket, chamber 9

charging wire for trailer fridge / 13pin socket, chamber 10

trailer / trailer recognition

Permanent current power supply

Ground or Earth (31)

ground connection battery terminal lug

positive connection battery terminal lug

fuse / fuse capacity 20 Ampère

12V

P

cigarette lighter /accessory socket

loudspeaker / buzzer

Park Distance Control

switch / source of function

Connect together

Disconnect

Look at / See further information

Look carefully at selected area

Present / Occupied / OK

Not present / Not occupied / Not OK

left

right

acoustic indication

attention / important advice

everse

+-

Tools

4/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

1.

2.

3.

4. 5.

6.7.

8. 9.

10. 11.

Scenica

2

12V12V

5/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

Grand Scenica

b

1.

2.

1.

2.

3. 3.

4.

5.

3

6. 7.

8.

90500380

D FGB IE

RD

BK

GN

OR

VT

PK

BL

YL

WT

BR

GY

Black Schwarz Negro Noir Nero

Red Rot Rojo Rouge Rosso

Green Grün Verde Vert Verde

Orange Orange Naranja Orange Arancione

Violet Violett Violeta Violet Viola

Pink Pink Pink Rose Rosa

Blue Blau Azul Bleu Blu

Yellow Gelb Amarillo Jaune Giallo

White Weiss Blanco Blanc Bianco

Brown Braun Marrón Brun Marrone

Grey Grau Gris Gris Grigio

NL NP SDK

Preto Zwart Sort Svart

Vermelho Rood Rød Rød Röd

Verde Groen Grøn Grønt Grön

Laranja Oranje Orange Orange Orange

Violeta Violet Violet Fiolett Violett

Cor-de-Rosa Paars Pink Pink Rosa

Azul Blauw Blå Blått Blå

Amarelo Geel Gul Gult Gul

Branco Wit Hvid Hvitt Vit

Marrom Bruin Brun Brunt Brun

Cinzento Grijs Grå Grått Grå

CZFIN H

Musta Cerná Fekete

Punainen Cervená Piros

Vihreä Zelená Zöld

Oranssi Narancs

Violetti Fialová Ibolya

Pinkki Ruzová Rózsaszín

Sininen Modrá Kék

Keltainen Zlutá Sárga

Valkoinen Bílá Fehér

Ruskea Hnedá Barna

Harmaa Sedá Szürke

PL

Czarny

Czerwony

Zielony

Pomaranczowy

Fioletowy

Rózowy

Niebeski

Zólty

Bialy

Brazowy

Szary

Svart

Oranzová

90500580

4 5

6 7

8

9 10

1.

2.

1 = BK

2 = BR/WT90500750

6/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

Grand Scenic

Scenic20mm

30mm

Grand ScenicScenic

Belegung der Steckdose/Socket ConfigurationCorrespondance des Contacts de la priseCavi della presa ellettrica sono abbinatiIndeling van de stekkerdoos / maximaal uitgangsvermogen

ISO 1724

5/58-R

6/54STOP

1/L

4/R

2

3/31

BK/WT

WT

BK/GN

BR

GY/RD

BK/RD

7/58-L GY/BK

21W

42W

21W

52W

63W

52W90500167

90500552

1 = BL/GN2 = BK/YL3 = GY/GN 4 = BR

1 = YL/GN2 = BK/YL3 = GY/GN4 = BR

Scenic

1 = BK/YL2 = GY/GN3 = BL/GN 4 = BR

1 = BK/YL2 = GY/GN3 = YL/GN4 = BR

Grand Scenic

11 12

13

14

15

7/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

123

4

123

4

Close secondary

lock!

123

4

123

4

Close secondary

lock!

Grand Scenic

Grand ScenicScenic

1 = BL/WT2 = BK/YL3 = GY/WT 4 = BR

1 = YL/WT2 = BK/YL3 = GY/WT4 = BR

Scenic

1 = BK/YL2 = GY/WT3 = BL/WT 4 = BR

1 = BK/YL2 = GY/WT3 = YL/WT4 = BR

Grand Scenic

16 17

18

19

20 21

8/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

Scenic

123

4

123

4

Close secondary

lock!

123

4

123

4

Close secondary

lock!

22

23

24

25

9/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

RD/YLRD

Scenic Grand Scenic

B+30

Grand ScenicScenic

Grand ScenicScenic

GY

PK

+

-

GY/YLPK

GY GY

Grand ScenicScenic

GY

BK/BL

everse everseeverse

+

-

30 31 - 34

35-43

P

P

Grand Scenic

29 31 - 34

35 - 43

P

P

Scenic

36 - 43 36 - 43

26

27 28

30

10/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

Grand ScenicScenic

16-pin / BR

PGrand ScenicPDC control unit

29

16-pin / BR

PScenicPDC control unit

16-pin / BR

PGrand Scenic

Scenic

BR/WT

chamber 11

PGrand Scenic

Scenic

BR

PGrand Scenic

Scenic

PDC control unit

16-pin / BR

PGrand Scenic

Scenic

31 32

33 34

35

36

11/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

Grand ScenicScenic

BR/WT

P

Grand ScenicScenic

20 A

20 Afuse

chamber 11

MANUAL

90500004

everse

37 38

39 40

41 42

90500652

Supplementary harness

12S38400501

BL/YL

OPTIONALeverse

43

12/1287180791 / 07.10.2009

© ConWys AGWeb: www.rightconnections.co.ukemail: enquiries@rightconnections.co.uk

Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366

Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT

90500331

13-pin7-pin

Optional: Adapter socket 62400001

90500543

P

90500545

P

21W 21W

top related