elisa pp 1.2

Post on 13-Jul-2015

1.330 Views

Category:

Documents

3 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Welcome!

• Heinen + Löwenstein GmbH

• Arzbacher Straße 80

• D-56130 Bad Ems

• Tel. +49 (0) 2603 9600-0

• Fax +49 (0) 2603 960050

• www.hul.de

4UTECH

4U-TECH CORPORATION SDN. BHD. (524775-V)

Presented by:

Ahmad Mohim Ahmad Khairudin

Service Centre Manager

4U-Tech Corporation Sdn Bhd - Operation Group Organization Chart Year 2009

44UU TECH

Rushdan Bin Rusmi General Manager

44UU TECH

Alkusaie Bin Abd Rahim Consultant, Business Development

Afdzal Bin Rusmi Sales & Marketing Manager

Ahmad Mohim Ahmad KhairudinService Centre Manager

Zulhilmi Bin Shahri Biomedical Technical Executive

Muhammad Salman Bin Baharom Biomedical Technical Executive

Surya Suhaimi Bin Hussein Biomedical Technical Executive

Abdul Fattah Bin Shaharudin Biomedical Technical Executive

44UU TECH

44UU TECH

44UU TECH

44UU TECH

44UU TECH

44UU TECH

44UU TECH

Presented by:

Ahmad Mohim Ahmad Khairudin

Service Centre Manager

Leon Plus – Anesthesia Unit, Workstation

Leoni 2 – Ventilator Acute, Neonate/ Pediatric

Leoni Plus – Ventilator Acute, Neonate/ Pediatric (HF)

Leoni 2 – Ventilator Acute, Neonate/Pediatric

Lifetherm 2003 – Infant Radiant Warmer

Elisa – Newborn /Adult Ventilator

Sonata – Newborn /Adult Ventilator

Elisa ICU Ventilator

General Description

• Intensiv Care Ventilator for– Adult– Pediatric (min. 5 kg)– Neonates (min. 2 kg – 6 kg)

• The system is:– Time controlled– Volume constant– Pressure cycled– Software controlled

General Description

• Expiration Valve is electromechanically controlled

• Expiration Valve is electromechanical locked

• Flowtrigger

• Permanent Byflow

• spontaneaus breathing in all ventilation modes

Features

• Individual ventilation strategies• Compact size ensures the highest performance combined

with a minimum need of floor space• Removable display• TFT, multicoloured• Patient Trigger visualized with different colour• Intuitive menu navigation • Comprehensive safety-concept (unintentional adjustments are

not possible, automatic patient detection, internal battery pack)

Features

• Innovative pre-oxygenation function to reduce oxygenation determined dystelectasis

• Continous Leakage measurement and Observation• Single Gas Option (only Air, only Oxygen possible)• Autoset Function (Alarm setting)• Stable expiration valve, quick and easy to remove for

cleaning and disinfection• Disposable flowsensors or other consumables has

been consciously rejected (economical)

Features

• Automatic adjustement of Starting Parameters related to the Bodyweight

• Automatical initiated Systemtest (45 sec. complete)

• Direct Start up Function in Emergency Case• Integrated Nebulizer• OCV Function• Special Measurement Tools• NIV (Non invasive Ventilation Mode)

• Nursecall

Ventilation modes

• VCV (Volume controlled Mode)

• AVCV (Assisted Volume controlled Mode)

• SIMV – VC (Synchroniced Intermittend Mandatory Ventilation – Volume Constant)

• Dyn - Bi – Level (Dynamic BiLevel Mode)

• Bi – Level (Pressure controlled)

• CPAP / PSV (Continous Positive Airway Pressure – Pressure supported Ventilation)

• NIV – Mode (Non – Invasive Ventilation) Option

V C VS I M V - V CB i - L e v e l V G

C P A P / P S VP r e v i o u s m e n u

B i - L e v e l

Special Functions

• OCV Function (Oxygen cell calibration during Ventilation)

• Inspiration Hold (X – Ray, Extension)

• Expiration Hold (X – Ray, PEEP intrinsic Tool)

• Manual Breath

• Nebulizer

• APD (Automatic Patient Detection)

• Tube Compensation

• ASR (Automatic Suction Routine)

Measured Values

• Standard Values– MV-E (Minute Volume expiratoric)

– VTe (expiratoric Tidalvolume)

– Ppeak– Pmin– O2 (Oxygen in percentage)

– Rate (frequency per minute)

Additional Measured Values

• Pressure:– peak– plateau– mean– min (smallest measured pressure

during ventilation)

– PEEP (Positive endexpiratory Pressure)

– PEEPi (intrinsic PEEP)

• Volumina:– VTi (inspiratoric Tidalvolume)

– MV (Minute Volume)

– MVsp (Minute Volume spontaneous)

– Rate sp (Frequency spontaneous)

• Dynamics:– Resistance– Compliance– RSBI (Rapid shallow breathing Index)

Alarming

Alarm Limits for Infant– MV max.– MV min.– Plimit– Pmax

Manual Setting of Alarm Limits Autoset Function (adaption to the actual measured values)

Alarm Limits Adult and Pediatric – MV max.– MV min.– Plimit– Pmax– AF max.– AF min.

Graphs and Loops

• Real time Measurement• Freezing Function (Loop)• Two graphs at a time• One Loop at a time• V / P and F / V

Graphs and Loops Visualization Patient Trigger

Trending

• Numerical Trending• Event Log

Different SolutionsIntegration of compressor Wall mounting

External Battery Backup