engines. vehicle / heavy equipment safety inspection checklist of 296
Post on 01-Jan-2016
224 Views
Preview:
TRANSCRIPT
ENGINES
VEHICLE /HEAVY
EQUIPMENTSAFETY
INSPECTIONCHECKLIST
OF 296
ADDITIONAL FORMS
ADDITIONAL FORMS
TYPE 3 4 5 6 7
PUMP CAP.
GPM 150 50 50 50 10
PSI 250 100 100 100 100
TANK CAP
MIN. GAL. 500 750 400 150 50
MAX. GAL. 1500 1500 749 399 200
1” HOSE
¾” INSIDE DIA. 100 FT 100 FT 100 FT 100 FT
1 ½” HOSE 1000 FT 300 FT 300 FT 300 FT
1 “ HOSE 500 FT 300 FT 300 FT 300 FT 200 FT
¾” HOSE 300 FT 300 FT 300 FT 300 FT
PUMP & ROLL YES YES YES YES
FOAM PROP. SYS. YES YES YES YES
MAX. GVWR (lbs) 26,000 19,500
PERSONNEL 3 3 3 3 2
MINIMUM STDS FOR ENGINES
EQUIPMENT REQUIREMENTS
Shall not exceed manufactures GVWR.
Shall not exceed manufactures GAWR.
Vehicle weighed:Fully loadedFull of fuel including any extra fuel cansFull of waterAdd 250 lbs per person
Four wheel drive:Type 6 – RequiredType 3,4,&5 - Optional
Tires:Load ratingAll season or mud & snow treadMinimum tread depthsSpare tire
BACKUP ALARM
RADIO’S
www.fireradios.net
VEHICLE MARKINGS
COMPANYNAME
#33
CHAINSAW
CHAINSAW INSPECTION FORM
HOSE REEL
REELTEX HOSE
BAFFLING
TANK SECUREMENT
Foam Capabilities:
Required on all engines
3 Types
Manually Regulated Proportioning SystemAutomatic Regulating Proportioning SystemCompressed air foam system (CAFS)
Minimum 5 gallons foam
MANUALLY REGULATED PROPORTIONING SYSTEM
A proportioning system that requires manual adjustment to maintain the proportioning ratio when there is a change of flow or pressure through the foam proportioner.
Typical manually regulated foam systems include:Suction side proportionerIn-line eductorAround-the- Pump Proportioner Direct injection manually regulated proportioners
Examples:Blizzard WizardScotty Foam InductorFoam Flo
AROUND THE PUMP
AUTOMATIC REGULATING PROPORTIONING SYSTEM
A proportioning system that automatically adjusts foam the flow of foam concentrate into the water stream to maintain the desired proportioning ratio.
These automatic adjustments are made based on changes in water flow or conductivity.
Examples:Foam Pro 1601/2001Robwen 500Darley Fast-foam SystemAqui 1.5/2.5 Foam System
AUTOMATIC REGULATINGPROPORTIONING SYSTEM
COMPRESSED AIR FOAM SYSTEM
COMPRESSED AIR FOAM SYSTEM
PUMPS
Discharge Press.Gauge 1 ½” Discharge
Drafting
PUMPS
Pressure ReliefValve
Positive Displacement
Pump
PUMP TEST KIT
NH NPSHNATIONAL HOSE NATIONAL PIPE STRAIGHT HOSE
GARDEN HOSE
PERSONAL PROTECTIVE EQUIPMENT
Fire shelters
Nomex Shirt & Pants
Hardhat
Gloves
Boots
OTHER PERSONAL EQUIPMENTREQUIRED
Eye Protection
Hearing Protection
Headlamp
Line Gear