Expert Software Tools forExpert Software Tools for

Unfailing Water QualityUnfailing Water Quality

WWTPs Design, Upgrading, Control

and Maintenance

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

Apeldoorn, 21th March 2003 Ing. Giovanni Mappa, ANOVA

Meeting - TNO Environment, Energy and Process innovationMeeting - TNO Environment, Energy and Process innovation

Aims & Issues

Unfailing Water Quality based on Early Unfailing Water Quality based on Early Warning Investigation & ExploitationWarning Investigation & Exploitation

Weaknesses in WWTPs Efficiency Management (Biological treatments, etc.)

Opportunities: Holistic approach to unfailing water quality control and Driver Indicators

Centro Direzionale is.G1 80143 – Napoli – 081 750.25.35 www.anova.it

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

When water quality fails, there are 4 possible reasons:

1. Influent Water Quality Lower than the fixed one

2. Low efficiency of some process treatment (design, management)

3. Equipment failures (maintenance)

4. A combination of above-mentioned problems

Centro Direzionale is.G1 80143 – Napoli – 081 750.25.35 www.anova.it

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

Input Data

• Idraulic and pollution load • Chemical-physical LAB analysis• Control and evaluation parameters on field• Visual Investigations• Microscopic Analysis (Morphology of Floc,

Filamentous & Microfauna)

• Operative Equipment Work Flow• Efficiency Assessment of Equipment

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

KERNEL(Rete Neurale di Matrici di Sintesi MQC)

DIAGNOSIS&

TroubleShooting

Floc Morphology

Chimical-Physical

Parameters

Operative Parameters

Visual Investigation

Filamentous

SBI- Microfauna

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

Sludge settability

Biological Efficiency

METADATA

DBMS

The Inferential KERNEL: a Fuzzy-MQC Neural Network

DATA-INPUT

X

Y

Z

Knowledge Surface

OD

Qi

MLSS

Qi

MLSS

SSe

Proccess Efficiency Indicator…

Centro Direzionale is.G1 80143 – Napoli – 081 750.25.35 www.anova.it

P (x,y,z)

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

Effluent

Influent

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

for Design,

Upgrading, Control

and Active Maintenance

of Waste Water

Treatment Plants

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

SWater

Multifunctional Process Control Tool for Wastewater Treatment Plants

IMPIANTO DI DEPURAZIONE "FOCE REGI LAGNI"Tot. popolazione servita: 633.000 ab/eqPortata media in tempo asciutto: 4.850 m3/hPortata max in tempo di pioggia: 24.250 m3/hPortata max al Biologico: 12.125 m3/hCarico inquinante in ingresso BOD5: 37.980 Kg/dPortata S.S. in ingresso impianto: 56.960 Kg/d

Centro Direzionale is.G1 80143 – Napoli – 081 750.25.35 www.anova.it

Centro Direzionale is.G1 80143 – Napoli – 081 750.25.35 www.anova.it

Affinamento TERZIARIO ad

Ozono

Stabilizzazione AEROBICA dei

Fanghi

MLSS, DO Liquame/Fango)

Qw, SSr

Fango di supero

Qr, SSr

Fango di Ricircolo

Liquame influente

Qi, BOD)

Effluente chiarificato

SSe

O2 O2

Reattore biologico

Sedimentatore II

ACTIVATED SLUDGE DIAGNOSTIC TOOLBased on MICROscopic Analysis and

a Holistic Expert Investigation

MICRO

expert

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

Centro Direzionale is.G1 80143 – Napoli – 081 750.25.35 www.anova.it

Floc Morphology – Filament Abundance…

3- Common

2- Some1- Few

4- Very Common

5- Abundand 6 - Excessive

Centro Direzionale is.G1 80143 – Napoli – 081 750.25.35 www.anova.it

Filamentous and Bulking …

M. parvicella

Beggiatoa spp.

S. natans

Type 021N

Nocardia spp. Thiothrix spp.

SBI

Anomalies & Cause

Microscopic Analysis…

Protozoa Identification…

Monitoring, Diagnosis and Corrective Actions …

TRAINING STAGE

INTESYS

“Aware” Monitoring and Control Software

for Water Treatment Processes

Multifunctional Water Monitoring …

Effluent

Influent

www.anova.it Centro Direzionale is.G1 80143 – 80143 Napoli (ITALY) – Tel 0039 081 750.25.35

Active Maintenace for instrumentation …

EarlyWarning Monitoring for Anaerobic Digester…

Troubleshooting for Anaerobic Digester…

EarlyWarning Maintenance Software for Water Treatment Processes

EarlyMAN

Monitoring for Anaerobic Digester…

top related