features indications contraindications fabrication...indications contraindications stroke cerebral...

Post on 15-Sep-2020

11 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Indications

Contraindications

Stroke

Cerebral palsy

Multiple sclerosis

Spina bifida

Spinal cord injury

Charcot-Marie-Tooth

Other neuromotor deficits

•••••••

Lower limb functional deficits as a result of:

Patient weight greater than 110 kg (240 lb)

Independent adjustment of:

Ankle alignmentPlantarflexion/dorsiflexion range of motionPlantarflexion spring stiffness

Independent ankle alignment range of 10°

(5) high stiffness spring options included with booster spring models (Figure 1)

Compatible with unilateral or bilateral orthotic designs

Features

Product Data Sheet

Adult 2.0 Ankle Joint( 19mm Systems )

Model 3A76 Component Selection

*Important: Thermoplastic unilateral AFOs require Camber Axis Triple Action® Companion Joint, or other free motion ankle joint

FabricationOptions

Thermoplastic

5mm (3/16") Polypropylene Unilateral*

Bilateral5mm (3/16") Polypropylene

Composite

Unilateral

Bilateral

Wet Lamination like Becker BCO Shadow™, Max™ or PrePreg

Wet Lamination like Becker BCO Lite™, Shadow™, Max™ or PrePreg

Patent #10,500,081©2020 Becker Orthopedic Appliance Co.,All rights reserved.Revision 08/01/20

Acorn Regulatory Consultancy Services Limited

Knockmorris Cahir Co. TipperaryIreland, Postcode: E21 R766

P 012 4626 8456 F 012 4626 8648

NORMAL

100 kg / 220 lb

110 kg / 240 lb

No Booster Plantarflexion Resist Booster

3A76-A1* 3A76-A0* 3A76-A23A76-A3

NORMAL

ABNORMAL

ABNORMAL

NORMAL

ABNORMAL

RightLeftRight RightLeft LeftRight

Lateral MedialLateral Medial Lateral MedialLateral Medial

BoosterConfiguration

Unilateral

Side

Order No.

Bilateral

Early StancePhase

Late StancePhase

Leg Left

No Booster Plantarflexion Resist Booster

3A76-A1* 3A76-A0* 3A76-A23A76-A3

RightLeftRight

Lateral MedialLateral Medial

Left RightLeftRight

Lateral MedialLateral Medial

Left

*Only available direct from Becker Orthopedic in some countries

No Yes Yes Yes

X1(low)

X2(moderate)

X4(high)

X5(very high)

High &StandardStandard HighNone

StandardStandardStandard Standard

Booster Required

Bottom Spring

Top Spring

Stiffness

10° 10° 10° 10°Max. ROM

1 2 3 4SPRINGCONFIGURATION

*Figure 1

0

No

X0.5(low)

None

Long ROM

18°

Spring Configurations

Stirrup Options

Y-Stirrup Model 3A76-YR-1 & Model 3A76-YL-1

Accessories

Fabrication Tool KitModel 3A00-FTK

Camber Axis Triple Action® Companion Joint

Model 751-ATA

The fabrication tool kit includes fabrication dummies, alignment axis, attachment hardware and wrenches.

Product Data Sheet

Adult 2.0 Ankle Joint( 19mm Systems )

Patent #10,500,081©2020 Becker Orthopedic Appliance Co.,All rights reserved.Revision 08/01/20

Acorn Regulatory Consultancy Services Limited

Knockmorris Cahir Co. TipperaryIreland, Postcode: E21 R766

P 012 4626 8456 F 012 4626 8648

Medial Stirrup

Models 3A76-MEDR-1 & 3A76-MEDL-1

Lateral Stirrup Models 3A76-LATR-1 &

3A76-LATL-1

Universal Rivet Stirrup

Model 3A76-R-1

*Internal bottom spring under booster is covered with a lifetime warranty for defects in materials and workmanship.

*The Booster Spring Unit cannot be removed from the Triple Action component housing. Doing so will destroy the Booster and void the product warranty.