Roof exhaust trapFlat roof ventilators
Features
Steel : Structural galvanized steel ZF75 Gauge : 24 & 26 Storm proof : Unique precision engineered deflector system Rodent proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection. Warranty : Limited Lifetime Warranty on all manufac-turing defects, 5 years on paint & corrosion.
FLAT ROOF4 models for
Warning :
Before venting an attic space, make sure that
the building in question complies with the
Building Code Requirements.
Model VMAX-102-12
Deflector : 1 Base : 45 degree cant. Height : 231/4 in. NFA : 96 in.2 Ventilation Area : 100 to 150 ft.2 Colours : Black, brown, grey and white CSA : Approved
Model VMAX-101-12
Deflectors : 4 Base : 45 degree cant. Height : 241/2 in. NFA : 144 in.2 Ventilation Area : 151 to 400 ft.2 NB : For net air space between insulation & underside of roof deck of 6 in. and more Colours : Black, brown, grey and white CSA : Approved
Model VMAX-102-12-MB
Deflector : 1 Base : insulated interior Height : 241/4 in. NFA : 96 in.2 Ventilation Area : 100 to 150 ft.2 Colours : Black, brown, greyand white CSA : Approved
Model VMAX-201-12-MB
Deflectors : 4 Base ; insulated interior NFA : 121 in.2 Height : 241/2 in. Ventilation Area : 151 to 450 ft.2 NB : For net air space between insulation & underside of roof deck of 6 in. and more Colours: Black, brown, greyand whiteCSA : Approved
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Flat roof ventilators
MODEL VMAX-102-12
Description
Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a “chimney or, vacuum effect” results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space.
This model has been designed to be installed onto a wooden curb. The thickness of the wooden curb in conjunction with the thickness of the roofing membrane will determine the size of the ventilator required. The interior dimension of the wood curb should equal to the opening in the deck to allow for unobstructed air flow. The suggested roof area for one (1) ventilator model VMAX-102-12 has been calculated based on a 10 in. x 10 in. opening or (hole) of curb and roof deck.
Specifications & Features
Model : VMAX-102-12 Deflector : 1 Net Free Evacuation : 96 in.2 Suggested Ventilation Area : 100 to 150 ft.2 Tested Extraction Rate: 134 CFM Base Flashing : 45 degree cant flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM-527
Note :
A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order.
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Roof exhaust trap
B
A
C
D
Please refer to the section on recommendations for flat roofs for additional information.
DIMENSIONS AND SPECIAL CHARACTERISTICS
Note :
The models #102-14 to #102-24 are available by special orders only.
Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season.
We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job.
CODE#DIMENSIONS THE NET
VENTILATIONEVACUATION
FOR MODEL 102-12
102-12 96 IN.2 26
26
24
24
24
24
24
24
22&24
22&24
22&24
22&24
22&24
22&24
0.062 M.2
150 IN.2
0.097 M.2
208 IN.2
0.134 M.2
266 IN.2
0.172 M.2
352 IN.2
0.227 M.2
408 IN.2
0.263 M.2
486 IN.2
0.314 M.2
METRIC(mm)
102-14
102-16
102-18
102-20
102-22
102-24
STEELGAUGEUSEDA B C D
19.5” 12” 5.00” 19”
495 305 127 483
24” 14” 6.50” 21.5”
26” 16” 6.50” 21.5”
660 406 165 546
28” 18” 6.50” 21.5”
711 457 165 546
32” 20” 9.5” 20”
813 508 241 508
34” 22” 9.50” 20”
864 559 241 508
36” 24” 9.50” 20”
914 610 241 508
609 356 165 546
NUMBEROF
DEFLECTOR
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Warning :
Before venting an attic space, make sure that
the building in question complies with the
Building Code Requirements.
Flat roof ventilators
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Roof exhaust trap
MODEL VMAX-101-12
Description
Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a “chimney or, vacuum effect” results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space.
This model has been designed to be installed onto a wooden curb. The thickness of the wooden curb in conjunction with the thickness of the roofing membrane will determine the size of the ventilator required. The interior dimension of the wood curb should equal to the opening in the deck to allow for unobstructed air flow. The suggested roof area for one (1) ventilator model VMAX-101-12 has been calculated based on a 10 in. x 10 in. opening or (hole) of curb and roof deck.
Specifications & Features
Model : VMAX-101-12 Deflectors : 4 Net Free Evacuation : 144 in2. Tested Extraction Rate : 418 CFM Suggested Ventilation Area : 151 to 400 ft2. (Refer to chart) Base Flashing : 45 degree cant flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM-527
Net Ventilation airspace between
underside of roofdeck & insulation
Roof Area that oneVentilation 101 (12” x 12”)
can ventilate
101 is not recommendedUse Model 1021 in. to 6 in.
151-200 ft.27 in. to 12 in.
201-300 ft.213 in. to 24 in.
301-400 ft.225 in. and more
VENTILATION CHART FOR MODELVMAX-101-12
Note :
A limited selection of special colours are available at a small premium. Please refer to chart above for net ventilation area capacity and the chart on the following page for larger dimensions that are available by special order.
Flat roof ventilators
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Roof exhaust trap
Note :
The models #101-14 to #101-24 are available by special orders only.
Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season.
We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job.
Please refer to the section on recommendations for flat roofs for additional information.
DIMENSIONS AND SPECIAL CHARACTERISTICS
CODE#DIMENSIONS
EVACUATIONNUMBER
OFDEFLECTORS
101-12 144 IN.2 4
4
5
5
6
6
7
24&26
24&26
22&24
22&24
22&24
22&24
22&24
0.0929 M.2
196 IN.2
0.126 M.2
256 IN.2
0.165 M.2
324 IN.2
0.209 M.2
400 IN.2
0.258 M.2
484 IN.2
0.312 M.2
576 IN.2
0.372 M.2
101-14
101-16
101-18
101-20
101-22
101-24
STEELGAUGEUSEDA B C D
12” 19.50” 11” 12.25”
305 495 279 311
14” 21.62” 11” 20.50”
16” 23.62” 13.25” 20.50”
406 600 337 521
18” 25.62” 13.25” 20.50”
457 651 337 521
20” 27.62” 15.75” 20.50”
508 702 400 521
22” 29.62” 15.75” 20.50”
559 752 400 521
24” 31.62” 18.25” 20.50”
610 803 464 521
356 549 279 521
METRIC(mm)
B
AD
C
Warning :
Before venting an attic space, make sure that
the building in question complies with the
Building Code Requirements.
Flat roof ventilators
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Roof exhaust trap
MODEL VMAX-102-12-MB
Description
Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a “chimney or, vacuum effect” results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space.
All in one, no need of a wood curb, this model has been desi-gned to allow you to install the roofing membrane onto the base flashing the same way you would a wood curb. We have made an allowance for the membrane so that the neck of the ventilator will go over both the flashing and the membrane.
Specifications & Features
Model : VMAX-102-12-MB Deflector : 1 Net Free Evacuation : 96 in2. Tested Extraction Rate : 134 CFM Suggested Ventilation Area : 100 to 150 ft2. Base Flashing : Flat base, insulated interior flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey and white Compliances : CSA, CAN-3-A930M82, ASTM-527
Note :
A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order.
The opening of the base flashing should equal to the opening in the deck to allow for unobstructed air flow.
Flat roof ventilators
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Roof exhaust trap
B
A
C
D
Note :
The models #102-14-MB to #102-24-MB are available by special orders only.
Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season.
We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job.
Please refer to the section on recommendations for flat roofs for additional information.
CODE#DIMENSIONS
EVACUATIONNUMBER
OFDEFLECTOR
102-12-MB 96 IN.2 1
1
1
1
1
1
1
1
1
1
1
1
1
1
26
26
24
24
24
24
24
24
22&24
22&24
22&24
22&24
22&24
22&24
0.062 M.2
144 IN.2
0.093 M.2
196 IN.2
0.127 M.2
256 IN.2
0.165 M.2
324 IN.2
0.209 M.2
400 IN.2
0.258 M.2
484 IN.2
0.312 M.2
102-14-MB
102-16-MB
102-18-MB
102-20-MB
102-22-MB
102-24-MB
STEELGAUGEUSEDA B C D
19.75” 12” 5” 15”
502 305 127 381
24” 14” 6.50” 17.5”
26” 16” 6.50” 17.5”
660 406 165 445
28” 18” 6.50” 17.5”
711 457 165 445
32” 20” 9.50” 16”
813 508 241 406
34” 22” 9.50” 16”
864 559 241 406
36” 24” 9.50” 16”
914 610 241 406
610 356 165 445
METRIC(mm)
DIMENSIONS AND SPECIAL CHARACTERISTICS
Warning :
Before venting an attic space, make sure that
the building in question complies with the
Building Code Requirements.
Flat roof ventilators
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Roof exhaust trap
Description
Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a “chimney or, vacuum effect” results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space.
All in one, no need of a wood curb, this model has been desi-gned to allow you to install the roofing membrane onto our base flashing the same way you would a wood curb. An allowance has been made for the membrane so that the neck of the ventilator will overlap both the flashing and the membrane.
Specifications & Features
Model : VMAX-201-12-MB Deflectors : 4 Net Free Evacuation : 121 in2. Tested Extraction Rate : 351 CFM Suggested Ventilation Area : 151 to 450 ft2. (Refer to chart above) Base Flashing : Flat base with insulated interior Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : 24 & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM-527
Net VentilationArea between
roof deck & insulation
Roof Area that oneVentilation 201-12-MB
(12” x 12”) can ventilate
201-12-MB is not recommendedUse Model 102-MB1 in. to 6 in.
151 to 250 ft.27 in. to 12 in.
251 to 350 ft.213 in. to 24 in.
351 to 450 ft.225 in. and more
VENTILATION CHART FOR MODELVMAX-201-12-MB
MODEL VMAX-201-12-MB
Note :
A limited selection of special colours are available at a small premium. Please refer to chart above for net ventilation area capacity and the chart on the following page for larger dimen-sions that are available by special order.
The opening of the base flashing should equal to the opening in the deck to allow for unobstructed air flow.
Flat roof ventilators
9229 Pierre Bonne, Montreal H1E 7J6 Tel.: 514-648-8011 Fax : 514-648-9129 Watts: (Canada) 1-800-665-4874 www.ventilation-maximum.com
Roof exhaust trap
Please refer to the section on recommendations for flat roofs for additional information.
DIMENSIONS AND SPECIAL CHARACTERISTICS
Note :
The models #201-14-MB to #201-24-MB are available by special orders only.
Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season.
We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job.
CODE#DIMENSIONS
EVACUATIONNUMBER
OFDEFLECTORS
201-12-MB 4
4
4
5
5
5
5
6
6
6
6
7
4
7
22&24
22&24
22&24
22&24
22&24
22&24
24&26
24&26
22&24
22&24
22&24
22&24
22&24
22&24
0.078 M.2
121 IN2
169 IN.2
0.109 M.2
225 IN.2
0.145 M.2
289 IN.2
0.186 M.2
361 IN.2
0.233 M.2
441 IN.2
0.285 M.2
529 IN.2
0.341 M.2
201-14-MB
201-16-MB
201-18-MB
201-20-MB
201-22-MB
201-24-MB
STEELGAUGEUSEDA B C D
13” 19.50” 11”
330 495 279
15” 11”
17”
432
19”
483
21”
533
23”
584
25”
635
381 279
METRIC(mm)
13.75”
349
21.62” 16.25”
23.62” 13.25” 16.25”
600 337 413
25.62” 13.25” 16.25”
651 337 413
27.62” 15.75” 16.25”
702 400 413
29.62” 15.75” 16.25”
752 400 413
31.62” 18.25” 16.25”
803 464 413
549 413
B
A
D
C
Warning :
Before venting an attic space, make sure that
the building in question complies with the
Building Code Requirements.