flow • level • pressure • temperature · exclusive north & south american agent for...
Post on 18-Aug-2018
216 Views
Preview:
TRANSCRIPT
PRECISION DIGITAL CORPORATION19 Strathmore Rd • Natick MA 01760 USA • Tel: (800) 343-1001 • Fax: (508) 655-8990www.predig.com
Exclusive North & South American Agent For Fluidwell Products
Fluidwell F-Series
Large LCD with backlight option
0.3” alphanumeric display
Status indicator
NEMA 4Xaluminum or plastic field enclosure
Engineering units
Clear 0.7” or1” digits
Measurement units for TOTAL
Operating temperature -40 to 80°C
Displayed function
Trendindication
Rugged tactile response keys
4-20 mA, 0-10 V, pulse, or RTD inputs
AC, DC, loop, or battery power
Rugged NEMA 4X enclosures
Field & panel mount enclosures
•
•
•
•
Intrinsically safe or explosion-proof
Operates from -40 to 80°C
Serial Modbus communications
Backlighting
•
•
•
•
Try the all new Fluidwell Configurator at: www.predig.com/configurator
Flow • Level • Pressure • Temperature
www.predig.com
Flow • level • Pressure • TemPeraTure • Precision DigiTal
2
See Data Sheets at www.predig.com for Complete Details
Batch controllersrate/Totalizers
Flow computers level, Pressure, & Temperature indicators
Analog or pulse inputMulti-point linearization7 digit flow rate display7 digit total display11 digit non-resettable totalBi-directional measurementHigh & low alarmsAnalog & pulse outputs
••••••••
Analog or pulse inputTemperature compensation
for liquids Temperature & pressure
compensation for gasRatio calculation & monitoringFuel consumption calculation11 digit non-resettable total
••
•
•••
Analog or pulse input1 or 2 stage batch controlStart, stop, & pause buttonsOverrun correctionCount up or count downFlow rate, preset value,
& total display11 digit non-resettable total
••••••
•
Analog or RTD inputMulti-point linearizationDisplays volume, height & % Dual pressure inputsHigh & low alarmsAnalog output
••••••
Battery-powered RTD temperature meter
Fluidwell F-Series Product Offeringsfor more details see the individual Quick Select Guides beginning on the next page
www.predig.com
accuracy • reliaBiliTy • convenience • Precision DigiTal
See Data Sheets at www.predig.com for Complete Details
Flow rate/Totalizers
Flow Rate/Totalizers Linearization High/low alarms
F010 F011 F012 F014 F110 F111 F115 F016 F112 F118 F013 F113
Flow
rate
indi
cato
r
Flow
tota
lizer
Flow
rate
/tota
lizer
with
pul
se o
utpu
t
with
pul
se &
ana
log
outp
uts
with
two
inpu
ts
&
two
puls
e ou
tput
s
with
bi-d
irect
iona
l m
easu
rem
ent
with
pul
se o
utpu
t
with
pul
se &
ana
log
outp
uts
with
pul
se &
ana
log
outp
ut &
two
flow
rate
ala
rms
Flow
rate
mon
itorin
gw
ith o
ne a
larm
out
put
Flow
rate
mon
itorin
gm
ax fo
ur a
larm
out
puts
Pulse, NAMUR, coil input 4 4 4 4 4 4 4 4 4 4 4 4
0-20 mA, 4-20 mA input 4 4 4 4 4 4 4 4 4 4 4
0-10 V input 4 4 4 4 4 4 4 4 4 4 4
Actual flow rate 4 4 4 4 4 4 4 4 4 4 4
Actual total (resettable) 4 4 4 4 4 4 4 4 4 4 4
Accumulated total (non-resettable) 4 4 4 4 4 4 4 4 4 4 4
Multi-point linearization 4 4 4
Analog output (flow rate) 4 4 4 4 4
Pulse output assigned to total 4 4 4 4 4 4 4 4
High & low alarms 4 4 4
Flow direction detection 4
Dual input 4 4
External reset total 4 4 4
RS-22, RS-485, TTL 4 4 4 4 4 4
Intrinsically safe or exp-proof 4 4 4 4 4 4 4 4 4 4 4 4
Backlight 4 4 4 4 4 4 4 4 4 4 4 4
Try the new Fluidwell Configurator at: www.predig.com/configurator
F111 with backlight off
F011 with backlight on F012, F014, F110, F115, F016, F112
F013 & F113 in alarm condition
Fluidwell F-Series Quick Select Guide
www.predig.com
Flow • level • Pressure • TemPeraTure • Precision DigiTal
4
See Data Sheets at www.predig.com for Complete Details
Flow computers
Flow Computers Ratio Differential/sum
F126-EL F126-EG F114 F116 F127-EL
Flow & temperature for liquid volume calc.
Flow, temp, & press. for gas volume calc.
Ratio calculation & monitoring
Consumption/sum calculation
Consumption calc. with temp correction
Pulse, NAMUR, coil input 4 4 4 4 4
0-20 mA, 4-20 mA input 4 4 4 4
0-10 V input 4 4 4 4
Actual flow rate 4 4 4 4 4
Actual total (resettable) 4 4 4 4 4
Accumulated total (non-resettable) 4 4 4 4
Actual temperature 4 4 4
Actual pressure 4
Analog output (flow rate) 4 4 4 4 4
Pulse output assigned to total 4
High & low alarms 4
Temperature compensation 4 4 4
Pressure compensation 4
Dual input 4 4 4
Fuel consumption calculation 4 4
Sum calculation (add on) 4
Ratio calculation 4
RS-22, RS-485, TTL 4 4 4 4 4
Intrinsically safe or explosion-proof 4 4 4 4 4
Backlight 4 4 4 4 4
Try the new Fluidwell Configurator at: www.predig.com/configurator
F126-EL with backlight off
F114 with ratio in alarm condition
F126-EG with backlight on
F116 & F127-EL with sum/differential
Fluidwell F-Series Quick Select Guide
www.predig.com
accuracy • reliaBiliTy • convenience • Precision DigiTal
5
See Data Sheets at www.predig.com for Complete Details
Fluidwell F-Series Quick Select GuideBatch controllers
Batch Controllers/Dispensers F030 F130 F131 F133 F136
with one stage control output
with two stage control or
pulse outputs
with two control/pulse & analog output
Delivery controller with batch counter
with two control/pulse
& analog output
Pulse, NAMUR, coil input 4 4 4 4 4
0-20 mA, 4-20 mA input 4 4 4 4
0-10 V input 4 4 4 4
Actual flow rate 4 4 4
Actual total (resettable) 4 4 4 4 4
Accumulated total (non-resettable) 4 4 4 4 4
Batch counter 4
Preset and actual value 4 4 4 4
Analog output assigned to rate 4
Analog output assigned to batch process 4
Pulse output assigned to total 4 4 4
1 stage control output 4 4 4 4 4
2 stage control output 4 4 4
Ticket printing 4
Overrun correction 4 4 4 4
External start/stop 4 4 4 4
RS-22, RS-485, TTL 4 4 4 4
Intrinsically safe or explosion-proof 4 4 4 4 4
Backlight 4 4 4 4 4
Try the new Fluidwell Configurator at: www.predig.com/configurator
F030, F130 & F136 with batch paused & backlight off
PAUSE
F131 & F133 with backlight on
www.predig.com
Flow • level • Pressure • TemPeraTure • Precision DigiTal
See Data Sheets at www.predig.com for Complete Details
level indicators
Level Indicators High/low alarms Linearization
F070 F073 F170 F077 F173
Level indicator with one alarm output
with analog & max four alarm outputs
with one alarm output
with analog & max four alarm outputs
0-20 mA, 4-20 mA input 4 4 4 4 4
0-10 V input 4 4 4 4 4
Displays volume, height, and percentage 4 4 4 4 4
Multi-point linearization 4 4
Analog output 4 4
High & low alarms 4 4 4 4
RS-22, RS-485, TTL 4 4
Intrinsically safe or explosion-proof 4 4 4 4 4
Backlight 4 4 4 4 4
Try the new Fluidwell Configurator at: www.predig.com/configurator
F070 with 1” high display & backlight on
F073 in alarm condition
F170 with high/low alarms& backlight on
F173 with linearization & backlight off
Fluidwell F-Series Quick Select Guide
www.predig.com
accuracy • reliaBiliTy • convenience • Precision DigiTal
7
See Data Sheets at www.predig.com for Complete Details
F143 with high/low alarms in alarm condition
Temperature Indicators High/low alarms
F040 F141 F043 F143
Temperature indicator Dual temperature indicator with one alarm output with analog & max four alarm outputs
0-20 mA, 4-20 mA input 4 4 4 4
0-10 V input 4 4 4 4
100 Ω RTD (Pt100) 4 4 4 4
Actual temperature & engineering units 4 4 4 4
Analog output 4
High & low alarms 4 4
Dual input 4
RS-22, RS-485, TTL 4 4
Intrinsically safe or explosion-proof 4 4 4 4
Backlight 4 4 4 4
Try the new Fluidwell Configurator at: www.predig.com/configurator
Temperature indicators
Pressure indicators
F151 with backlight on
Pressure Indicators High/low alarms
F050 F151 F053 F153
Pressure indicator Dual pressure indicator with one alarm output with analog & max four alarm outputs
0-20 mA, 4-20 mA input 4 4 4 4
0-10 V input 4 4 4 4
Actual pressure & engineering units 4 4 4 4
Analog output 4
High & low alarms 4 4
Dual input 4
RS-22, RS-485, TTL 4 4
Intrinsically safe or explosion-proof 4 4 4 4
Backlight 4 4 4 4
Fluidwell F-Series Quick Select Guide
Exclusive North & South American Agent for Fluidwell Products
Flow Rate Indicators
Flow Totalizers
Flow Computers
Batch Controllers
Transmitters
•
•
•
•
•
Fuel Consumption Computers
Setpoint Generators
Modbus Display
Loop-Powered Displays
Level Indicators
•
•
•
•
•
Flow • Level • Pressure • Temperature
Try the New Online Fluidwell Configurator! Go to www.predig.com/configurator
top related