from the dawn of excellence emanates the high noon of ... product literature 23.01.2014.pdf · 4 5...
Post on 20-May-2018
224 Views
Preview:
TRANSCRIPT
Gelco Electronics is a full service electronic company that manufactures superior quality electronic control &
measuring equipment alongwith power saving devices. Established in 1984, the company is located in the industrial
belt of Ahmedabad, which is one of the fastest developing metropolitan cities of India.
Our state of the art manufacturing facility with its prolific R&D centre in conjunction with our strict adherence
to quality control and safety norms has ensured an impressive growth record in these past three decades. More
importantly, it has gained a reputation of Excel- lence & Dependability from its clients.
After achieving wide success in the Indian market, Gelco Electronics is now spreading its wings internationally.
To attain the same level of success globally, Gelco Electronics has conducted extensive research in each
market to understand their electrical equipment’s needs and subsequently, developed specific products for
them that are longlasting, efficient and safe.
R a n g e o f PR o d u c t s
• Single Phase Motor Starters & Control Panel• Three Phase DOL Motor Starters & Control Panel• Three Phase Star Delta Motor Starters & Control Panel• Duty Stand by Panel for Duplex Pumps• Panel Accessories
a P P l i c at i o n s
• Home• Agriculture• Industries
1
note:• A wide range of products which can be offered on request.• We can supply starter / panel / A.T.S. panel / 60 Hz starter / panel as per customer’s specifications.• A wide range of lighting products which can be offered on request.• We can supply submersible flat & round, PVC & rubber, 3 core and 4 core cable.• We can supply submersible pumpsets, monoblock pumpsets, industrial pumpset, electric induction motors &
UPVC column pipes etc.• Due to continues R & D; specifications, construction of materials, design, out look, colour
& finishing etc. can be changed without intimation.
indeXTopic Page
Single Phase Motor Starter 1-2
Single Phase Electronic Control Panel 3
Three Phase Dol Motor Starter 4-5
Three Phase Dol Motor Starter - Metal Body 6
Three Phase Star Delta Motor Starter 7
Three Phase Dol Electronic Control Panel 8
Three Phase Star Delta Electronic Control Panel 9
Duty Stand By Panel For Duplex Pumps Operation 10
Stabilizer 11
Auto Switch 12
Motor Starter 13
A.C. Switch 14
Phase Failure Relay 15
Phase Failure Relay 16
Motor Protection Relay 17
Pump Protection Relay 18
Analog Timer 19-20
Digital Timer 21
Digital Time Switch 22
Earth Leakage Relay 23-24
Earth Leakage Circuit Breaker 25
Panel Meters 26
Automatic Light Controller 27
Spp With Water Level Guard 28
Water Level Controller 29-30
(1.1) | GSS-MCB
sa l i e n t fe at u R e s :• Easy to operate
• Overload protection through MCB
• Economical Solution
• Enclosure made from Engineering grade Plastic (ABS)
a P P l i c at i o n:Only for Oil Filled Pump set
Va R i a n t s:
Motor H.P. Run Capacitor MCB
0.75 HP 0 + 25 MFD 10 Amp.
1.0 HP 0 + 36 MFD 10 Amp.
1.5 HP 0 + 50 MFD 16 Amp.
2.0 HP 0 + 72 MFD 25 Amp.
(1.2) | GSS-RE
sa l i e n t fe at u R e s :• Electronic Start/Stop push buttons.
• Electronic Overload protection
• High voltage protection above 270 Vac.
• Low voltage protection below 150 Vac.
• Engineering grade plastic enclosure (ABS).
• Facility to connect Gelco Water Level Controller Adaptor
( LLC-001D/LLC-001)
a P P l i c at i o n:Only for Oil Filled Pump set
Va R i a n t s:
Motor H.P. Run Capacitor MCB
0.75 HP 0 + 25 MFD 4 - 10 Amp.
1.0 HP 0 + 36 MFD 4 - 10 Amp.
1.5 HP 0 + 50 MFD 10 - 16 Amp.
2.0 HP 0 + 72 MFD 10 - 16 Amp.
SINGLE PHASE MOTOR STARTERInput Supply voltage : 230V, AC ±20% | Output supply voltage : 230V, AC +20%
2 3
SINGLE PHASE ELECTRONIC CONTROL PANEL
(2.1) | MCB WS
sa l i e n t fe at u R e s :• In built digital Volt and Amp. Meter ( GELCO ACCURA)• Easy to operate• Powder coated sheet metal enclosure.
a P P l i c at i o n:• Submersible/Monoblock Pump set.
Va R i a n t s:
MCB Start Capacitor Run Capacitor
10 100/120 MFD 36 MFD
20 150/200 MFD 36 + 36 MFD
25 200/250 MFD 36 + 36 MFD
25 200/250 MFD 50 + 50 MFD
(2.2) | DCP - 7201
sa l i e n t fe at u R e s :• Fully automatic Electronic Start/Stop facility• Digital Micro Controller based technology• Higher accuracy• Digital indication of fault condition.• Precise overload protection( Over Current)• Precise Overvoltage protection• Precise Under voltage protection• Dry run Protection.• Parameters can be programmable• In built Auto ON/OFF timer ( 1-240 Minutes)• Powder Coated sheet metal enclosure.
a P P l i c at i o n:Submersible/Monoblock Pumpset for water in residence,
commercial, farming, gardening.
Va R i a n t s:
Motor H.P. Start Capacitor Run Capacitor
1.0 HP 100/120 MFD 36 MFD
1.5 HP 150/200 MFD 36 + 36 MFD
2.0 HP 200/250 MFD 50 + 50 MFD
(1.3) | DCP - RE
sa l i e n t fe at u R e s :• Electronic Start/Stop Push button.
• In built digital volt and amp meter
• Latest Micro Controller Based Technology for better accuracy
• Presice protection against Overload( Over Current)
• Presice protection aganist high voltage
• Presice protection against low voltage
• Dry run protection ( Optional)
• Digital indication of fault condition.
• Engineering grade plastic enclosure( ABS)
• Facility to connect GELCO Water Level Controller Adaptor
( LLC-001D)
• Parameters can be programmable
a P P l i c at i o n:Only for Oil filled pumpset
Va R i a n t s:
Motor H.P. Run Capacitor
1.0 HP 36 MFD
1.5 HP 50 MFD
2.0 HP 72 MFD
Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC ±20%
SINGLE PHASE MOTOR STARTERInput Supply voltage : 230V, AC ±20% | Output supply voltage : 230V, AC +20%
4 5
THREE PHASE DOL MOTOR STARTER Input/Output Voltage :415 V ± 20%VAC
(3.1) | GTWsa l i e n t fe at u R e s :• Current sensing unit• Inverse current characteristics• Electronic start/stop push button facility• Electronic overload protection.• Over voltage protection• Under voltage protection• Dry run protection(Optional)• Phase failure protection.• Reverse phasing protection• Engineering grade plastic enclosure(ABS)• Can be used up to 7.5Hp DOL moter/pumps• Other Models are also available on request
a P P l i c at i o n:• D.O.L. Submersible Pump set for water in residence,
commercial, farming, gardening.• Induction motor in industries
Va R i a n t s:
Type Current Range
GTW-304 2 - 5 Amp.
GTW-305 4 - 10 Amp.
GTW-306 8 - 20 Amp.
(3.2) | GTVsa l i e n t fe at u R e s :• All facilities available as per GTW• Current and voltage sensing unit• Facility to connect GELCO Water Level Controller
(Model LLC-001/LLC-001D)• Can be used up to 7.5Hp DOL moter/pumps
a P P l i c at i o n:• D.O.L. Submersible Pump set for water in residence,
commercial, farming, gardening.• Induction motor in industries
Va R i a n t s:
Type Current Range
GTV-304 2 - 5 Amp.
GTV-305 4 - 10 Amp.
GTV-306 8 - 20 Amp.
(3.3) | GTAsa l i e n t fe at u R e s :• Current Sensing Unit• Additional facility to make Motor/Pump ON
automatically after power supply resumption.• One minute Time Delay before start• Can be used up to 7.5Hp DOL moter/pumps
a P P l i c at i o n:• D.O.L. Submersible Pump set for water in residence,
commercial, farming, gardening.• Induction motor in industries
Va R i a n t s:
Type Current Range
GTA-304 2 - 5 Amp.
GTA-305 4 - 10 Amp.
GTA-306 8 - 20 Amp.
(3.4) | DCP - 304
sa l i e n t fe at u R e s :• Used latest Micro controller based technolgy• Electronic Start/Stop push button• Inbuilt digital volt & amp Meter• Digital display of fault condition• Electronic overload protection• Over voltage protection• Under voltage protection• Dry Run protection• Parameters can be programmed• Phase failure protection• Reverse phasing protection• Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D)• Engineering grade plastic enclosure(ABS)• Can be used up to 7.5Hp DOL moter/pumps
a P P l i c at i o n:• Three phase DOL Submersible/Monoblock Pump set
for water in residence, commercial, farming, gardening
Va R i a n t s:
Current Range
2 - 5 Amp.
6 7
THREE PHASE DOL MOTOR STARTER - METAL BODYInput Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC
THREE PHASE STAR DELTA MOTOR STARTERInput Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC
(4.1) | GEW-1(DOL)
sa l i e n t fe at u R e s :• Easy to operate• Powder Coated sheet metal enclosure.• Thermal Overload protection
a P P l i c at i o n:• D.O.L Motors for water in residence, commercial, farming, gardening.
Va R i a n t s:
Motor H.P. Overload range
5.0 HP 6 – 10 A
7.5 H.P 9 – 14 A
10 H.P 13 – 21 A
(4.2) | GLO-1 (DOL)
Va R i a n t s:
Motor H.P. Overload range
3.0 HP 6 – 10 A
5 H.P 6 – 10 A
7.5 H.P 10 - 16 A
(4.3) | GLO-1.5 / 2 / 3 (DOL)
Va R i a n t s:
Motor H.P. Overload range
10 HP 13 - 21 A
15 H.P 20 - 32 A
20 H.P 20 - 32 A
30 H.P 28 - 42 A
(5.1) | GLO-FASD / SA-Metal Body
Va R i a n t s:
Type Motor H.P. Overload range
GLO-1 3 HP 6 - 10 A
GLO-1 4 HP 6 - 10 A
GLO-1 5 HP 6 - 10 A
GLO-1 6 HP 6 - 10 A
GLO-1 7.5 HP 6 - 10 A
GLO-1 10 HP 6 - 10 A
GLO-1 12 HP 10 - 16 A
GLO-1.5 15 HP 13 - 21 A
GLO-2 20 HP 20 - 32 A
GLO-2 25 HP 20 - 32 A
GLO-3 30 HP 28 - 42 A
GLO-3 40 HP 28 - 32 A
8 9
THREE PHASE DOL ELECTRONIC CONTROL PANEL
(6.1) | DIGI : DOLsa l i e n t fe at u R e s :• In Built digital volt& Amp meter ( AVM-101)• With bright LED phase indication with flash• Automatic rotational phase to phase voltage indication• Thermal overload protection• Short circuit protection through MCB• Over voltage protection• Under voltage protection• Phase Failure Protection• Auto Start after resumption of Supply• Powder coated sheet Metal encloser
a P P l i c at i o n:• For 3 phase DOL Submersible/Monoblock Pump set at irrigation,
remote farms, unattainable gardening area.
Va R i a n t s:
Relay Range
4 - 6.5 Amp. 6 - 10 Amp. 9 - 14 Amp. 13 - 21 Amp.
(6.2) | DCP-9603sa l i e n t fe at u R e s :• Used latest Micro controller based technolgy• Electronic Start/Stop push button• Inbuilt digital volt & amp Meter• Digital display of fault condition• Electronic overload protection• Over voltage protection• Under voltage protection• Dry Run protection• Parameters can be programmed• Phase failure protection• Reverse phasing protection• Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D)• Remote ON/OFF• Powder coated sheet metal enclosure
a P P l i c at i o n:• Three phase DOL Submersible/Monoblock Pump set
for water in residence, commercial, farming, gardening.
Va R i a n t s:
Current Range
2 - 5 Amp. 4 - 10 Amp. 8 - 20 Amp.
Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC
THREE PHASE STAR DELTA ELECTRONIC CONTROL PANEL
(7.1) | DCP-9613
sa l i e n t fe at u R e s :• Fully Automatic Star delta starter• Used latest micro controller based technology• Inbuilt Digital volt /Amp Meter• Electronic Overload protection• Over voltage protection• Under Voltage protection• Dry run protection• Current sensing unit• Phase failure protection• Reverse phase protection• Parameters can be programmed• Inbuilt Auto ON/OFF timer• Powder coated sheet metal enclosure( IP55)• Easy to maintain detachable spares• Remote ON/OFF
a P P l i c at i o n:• For three phase star delta motors used in farms, pumping
station, municipal corporation
Va R i a n t s:
Motor H.P.Overload
rangeMotor H.P.
Overload
range
7.5 HP 8 - 20 Amp. 20.0 HP 16 - 40 Amp.
10.0 HP 8 - 20 Amp. 25.0 HP 16 - 40 Amp.
12.5 HP 8 - 20 Amp. 30.0 HP 32 - 80 Amp.
15.0 HP 16 - 40 Amp. 35.0 HP 32 - 80 Amp.
Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC
10 11
STABILIZER
(9.1) | SERVO
s e R V o co n t R o l l e d Vo lta g e sta b i l i z e R
• I/P: 170V to 270V (For 1 Phase)
360V to 460V (For 3 Phase)
• O/P: 215V AC +/- 1% for 1 Phase
415V AC +/- 1% for 3 Phase
• Capacity: Up to 400 KVA
• Cooling: Air Cooled
Oil Cooled
• Balance or Unbalance Type,
• Display Parameter: Digital Volt and Amp. Meter
• Protection: Over Voltage, Under Voltage, Overload,
Single Phasing Prevention
(9.2) | VIOLTEE
Model Input Range Output Range
Time Delay Application
GDMS-20 170V AC – 270V AC 220V AC ± 10% 10 Sec. Television
GDMS-50 170V AC – 270V AC 220V AC ± 10% 3 Min. Refrigerator
DLC-50 170V AC – 270V AC 210V AC – 230V AC 10 Sec. Computer
Model Input Range Output Range Time Delay
GDMS - 300 170V AC – 270V AC 220V AC ± 10% 3 Min.
GDMS - 400 170V AC – 270V AC 220V AC ± 10% 3 Min.
GDMS - 500 170V AC – 270V AC 220V AC ± 10% 3 Min.
DUTY STAND BY PANEL FOR DUPLEX PUMPS OPERATION
(8.1) | DUTY STAND BY PANEL FOR DUPLEX PUMPS OPERATION
sa l i e n t fe at u R e s :• Suitable for Single Phase & Three Phase Power Supply
• Volt Current and other Fault Conditions Display.
• Over voltage, under Voltage and Dry run Protection.
• Pump run and trip indication.
• Singe Phasing, Current and Voltage Sensing Protection.
• Selector/Toggle Switch for pump-1 and pump-2
parallel/alternate operation
• Manual/Auto ON/OFF
• Sheet metal enclosre with IP-55 Protection
a P P l i c at i o n:• Suitable for booster pumps application
Va R i a n t s:• Up to 35 HP
12 13
AUTO SWITCH
(10.1) | Auto Switch
sa l i e n t fe at u R e s :• Voltage sensing unit
• Phase failure protection
• Reverse phasing protection
• Engineering grade plastic enclosure (ABS)
• Auto ON after resumption of power supply
• Panel mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux Supply Voltage: 415V AC +/- 20 % , 50 Hz
• Phase unbalance volt: 45 V +/- 5 V
• Start Time delay: 1 Minute
• Output: 1 C/O, 6 Amp (Resi.)@ 230 VAC
a P P l i c at i o n:• For MCC of water pumps at remote farms, unattaindable area.
MOTOR STARTER
(10.2.1) | GSW
sa l i e n t fe at u R e s :• I/P: 230 V, 1Phase, AC Supply• ABS Body• High/Low voltage protection• Over Load Protection• Variable current (Amp.) Setting
Va R i a n t s:
Type Current Range:
GSW-104 2 - 5 Amp.
GSW-105 4 - 10 Amp.
GSW-106 8 - 14 Amp.
GSW-107 10 - 16 Amp.
GSW-108 14 - 22 Amp.
(10.2.2) | GSW-T
sa l i e n t fe at u R e s :• I/P: 230 V, 1Phase, AC Supply,• ABS Body• High/Low voltage protection• Over Load Protection• Time Delay Facility• Built in Starter• Variable current /AMP setting• Relay Type Switching device
Va R i a n t s:
Type Current Range:
GSW-T-104 2 - 5 Amp.
GSW-T-105 4 - 10 Amp.
GSW-T-106 8 - 14 Amp.
GSW-T-107 10 - 16 Amp.
GSW-T-108 14 - 22 Amp.
14 15
A.C. SWITCH
((10.2.2) | AaCcSVCH
sa l i e n t fe at u R e s :• Input Voltage: 85V Ac To 300V Ac• Current Range: 2A to 16A• High Voltage Protection : Above 280v• High Voltage Cut Off: Below 260v• Low Voltage Protection : Below 160v• Low Voltage Cut in : Above 175v• Over Load Protection programmable range 2A to 16A• Time Delay : 60 sec.(1minute) After resumption of power supply• Switching device : Relay• Unique Alarm system for High voltage, Low voltage,
Over load tripping• Display of live voltage and live current by seven segment LED• Display total run time of your load in hour
a P P l i c at i o n:• Air-Conditioner, Television, Refrigerator, Domestic Flour Mill
PHASE FAILURE RELAY
(10.3.1) | PFR-104
sa l i e n t fe at u R e s :• Micro controller based technology
• Slim in size
• Higher accuracy
• Voltage sensing unit
• Phase failure protection
• Reverse phasing protection
• Engineering grade plastic enclosure (ABS)
• DIN rail mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux Supply Voltage: 415V AC +/- 20 % , 50 Hz
• Phase unbalance volt: 45 V +/- 5 V
• Tripping delay: 4 to 7 sec
• Output: 1 C/O, 6 Amp (Resi.)
a P P l i c at i o n:• For MCC of water pumps, generators, compressors
(10.3.2) | PFR-105
sa l i e n t fe at u R e s :• Micro controller based technology
• Slim in size
• Higher accuracy
• Voltage sensing unit
• Phase failure protection
• Engineering grade plastic enclosure (ABS)
• DIN rail mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux Supply Voltage: 415 VAC +/- 20 % , 50 Hz
• Phase unbalance volt: 45 V +/- 5 V
• Tripping delay: 4 to 7 sec
• Output: 1 C/O, 6 Amp (Resi.)
a P P l i c at i o n:• For MCC of water pumps, generators,compressors
16 17
MOTOR PROTECTION RELAYPHASE FAILURE RELAY
(10.4.1) | MGR-101sa l i e n t fe at u R e s :• Current Sensing unit• Inverse current characteristics-2• Micro controller based technology• Electronic Over load protection• Over voltage protection• Engineering grade plastic enclosure(ABS)• DIN rail & Panel Mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux. Supply voltage 415 +/- 20 % VAC• Over voltage: 120% +/- 5 V of supply voltage• Under Voltage : 80 % +/- 5 V of supply voltage• Hysterius• Current unbalance Phase-Phase: 50 % of Full Scale current• Tripping Delay: 4 to 7 Sec.• Dry run : 40% to 80% of Overload Setting
a P P l i c at i o n:• MCC Panels of Water Pumps in hilly area.
(10.4.2) | MGR-102sa l i e n t fe at u R e s :• Current & Voltage Sensing unit• Inverse current characteristics-2• Micro controller based technology• Electronic Over load protection• Over voltage protection• Under voltage protection• Phase failure protection• Reverse phase protection• Engineering grade plastic enclosure(ABS)• DIN rail & Panel Mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux. Supply voltage 415 +/- 20 % VAC• Over voltage: 120% +/- 5 V of supply voltage• Under Voltage : 80 % +/- 5 V of supply voltage• Current unbalance Phase-Phase: 50 % of Full Scale current• Voltage Unbalance Phase-Phase : 45 +/- 5 V• Tripping Delay: 4 to 7 Sec.
a P P l i c at i o n:• MCC Panels of water pumps.
(10.3.3) | PFR-106
sa l i e n t fe at u R e s :• Micro controller based technology• Slim in size• Higher accuracy• Voltage sensing unit• Phase failure protection• Over voltage protection (PFR 106)• Under voltage protection (PFR 106)• Reverse phasing protection• Engineering grade plastic enclosure (ABS)• DIN rail mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux Supply Voltage: 415V AC +/- 20 % , 50 Hz• Phase unbalance volt: 45V +/- 5 V• Over voltage: Above 480 VAC• Under Voltage: Below 320 V• Tripping delay: 4 to 7 sec• Output: 1 C/O, 6 Amp (Resi.)
a P P l i c at i o n:• For MCC of water pumps, generators, compressors, Lift
18 19
PUMP PROTECTION RELAY
(10.5.1) | PGR-101
sa l i e n t fe at u R e s :• Current Sensing unit• Inverse current characteristics• Micro controller based technology• Electronic Over load protection• Over voltage protection• Under voltage protection• Phase failure protection• Reverse phase protection• Output 1 c/o, 6Amp.(Resi) at 230VAC• Dry run Protection ( Prodless )
(10.5.2) | PGR-102sa l i e n t fe at u R e s :• Current & Voltage Sensing unit• Inverse current characteristics• Micro controller based technology• Electronic Over load protection• Over voltage protection• Under voltage protection• Phase failure protection• Reverse phase protection• Dry Run protection ( Prodless )• Engineering grade plastic enclosure(ABS)• DIN rail & Panel Mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux. Supply voltage 415 +/- 20 % VAC• Over voltage: 120% +/- 5 V of supply voltage• Under Voltage : 80 % +/- 5 V of supply voltage• Current unbalance Phase-Phase: 50 % of Full Scale current• Voltage unbalance Phase-Phae : 45 V +/- 5 V• Dry Run : 40 % to 80 % of overload setting• Tripping Delay: 4 to 7 Sec.
a P P l i c at i o n:• MCC Panels of water pumps in hilly area
ANALOG TIMER
(10.6.1) | AC-22
sa l i e n t fe at u R e s :• Micro Controller based technology• Cyclic timer• Easy to programme ,through dial on front• DIN Rail Mountable• Engineering grade plastic enclosure(ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC• Output: 2 C/O Relay (5A @ 230 VAC)• Control Action: Cyclic• Time Range: 1-10 sec /min/hr. Selectable trough DIP Switch• Reset: Power On reset
a P P l i c at i o n:• MCC panel for water pumps, compressors, generators,
airconditioners
(10.6.2) | AS-22
sa l i e n t fe at u R e s :• Micro Controller based technology• Single action timer• Delay ON/ OFF timer (Selectable )• Easy to programme ,through dial on front• DIN Rail Mountable• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC• Output: 2 C/O Relay (5A @ 230 VAC)• Control Action: Selectable Delay ON/OFF• Time Range: 1/3/10/30 sec/min/hr. Selectable trough DIP Switch• Reset: Power On reset
a P P l i c at i o n:• MCC panel for water pumps, compressors, generators
20 21
ANALOG TIMER
(10.6.3) | AS-21
sa l i e n t fe at u R e s :• Micro Controller based technology• Single Action timer• Delay ON/OFF timer (Factory set)• Higher Accuracy• Easy to programme ,through dial on front• DIN Rail Mountable• Engineering grade plastic enclosure(ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC• Output: 1 C/O Relay (5A @ 230 VAC)• Control Action: Delay ON/ Delay OFF• Time Range: 0-60 sec• Reset: Power On reset
a P P l i c at i o n:• MCC panel for water pumps, compressors,generators , airconditioners
(10.6.4) | SD-22
sa l i e n t fe at u R e s :• Micro Controller based technology• Star Delta timer• Din rail Mountable• Higher Accuracy• Easy to programme• Engineering grade plastic Encloser(ABS)
te c h n i c a l s P e c i f i c at i o n s:• Supply: 110/230/415V AC ± 20% 50 Hz• Output: 2 No. 1 C/O (230V AC, 6A)• Time Range: y run up time 30/60 sec y to
Δ change over time 30-100msec• Reset: Power On Reset
a P P l i c at i o n:• MCC panel for Star Delta pumps set.
DIGITAL TIMER
(10.6.1) | DT-48
te c h n i c a l s P e c i f i c at i o n s:• Supply: 230V AC ± 20%, 50 Hz
• Output: 2 C/O Relay (5A @ 230 VAC)
• Control Action: Selectable Delay On/Off
• Time Range: 0-99.9 hr./min./sec.
• Display: 0.4” Seven Segment LED
• Accuracy: ± 0.01% of FSD
22 23
EARTH LEAKAGE RELAY
(10.8.1) | ELR-101
sa l i e n t fe at u R e s :• Micro Controller Based technology
• Higher precision
• Panel/Surface mountable
• Parameters are settable through knob in front panel
• Engineering grade plastic enclosure( ABS)
• With CBCT
te c h n i c a l s P e c i f i c at i o n s:• Auxiliary Supply: 110/280/415v, 50 HZ,
• Relay Contact: 1 C/O contact with 6 Amp.
• Resistive load at 230v AC,
• Leakage Current Range:
30 to 100 mA
0.1 to 1 Amp
0.5 to 5 Amp.
• Reset: Manual
• Operating Temp. : -5°C to 60°C
• CBCT : 70,100,200,300 & 400mm
a P P l i c at i o n:Distribution panels for hotels, commercial complex,
residential blocks, industrial complex. Mining industry
DIGITAL TIME SWITCH
(10.7.1) | DTS-502
sa l i e n t fe at u R e s :
• Micro controller based technology
• On/ Off time is programmable
• 10 No of programme for On/Off
• Display of real time clock
• LED display of unit On
• Easy to programme
• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:
• Input Supply: 230 +/- 20 % VAC
• Output Supply: 230 +/- 20 % VAC
• Capacity: 20 amp at 230 VAC (Resi.)
a P P l i c at i o n:
Water pump, Street lights
(10.7.2) | DTS-601
sa l i e n t fe at u R e s :• Micro controller based technology
• On/ Off time is programmable
• 10 No of programme for On/Off
• Display of real time clock
• LED display of unit On
• Easy to programme
• Engineering grade plastic enclosure (ABS)
te c h n i c a l s P e c i f i c at i o n s:• Input Supply:415 +/- 20 % VAC
• Output :Potential Free 1 Contact,6 amp at 230 VAC (Resi.)
a P P l i c at i o n:• Water pump, street lights
24 25
(10.8.2) | ELR-9601
sa l i e n t fe at u R e s :• Micro Controller Based technology
• Higher precision
• DIN standard flush mountable(92x92)
• Digital display of leakage current
• Parameters are programmable
• Engineering grade plastic enclosure( ABS)
• With CBCT
te c h n i c a l s P e c i f i c at i o n s:• Supply Voltage : 75-275V AC/DC, 50/60 Hz 415V AC,
• 50Hz ± 15%
• Relay contact : 1 change over
• Potential free contact
• Positive safety output (Relay will energies on fault)
• Contact Rating: 6A at 230V AC / 30V DC
• Leakage current range : 50-999mA
• Trip time set: 0.05 to 5 Sec.
• Display: Digital 7seg. LED display
• Operating temp. : -5°c to 60°c
• CBCT 70, 100, 200, 300 & 400mm
a P P l i c at i o n:Distribution panels for hotels, commercial complex, residential
blocks, industrial complex. Mining industry.
EARTH LEAKAGE CIRCUIT BREAKER
(10.9.1) | EL+MCB
sa l i e n t fe at u R e s :
• Load Current Rating: 16A / 25A / 32A
• System Voltage: 230V AC, 1 Phase, 50Hz,
• Sensitivity: 3-50 mA,
• Tripping Time: <30 ms.
• High/Low Voltage Cut off,
• Overload – Short Circuit Protection
EARTH LEAKAGE RELAY
26 27
(10.10) | AVM-101
sa l i e n t fe at u R e s :• Micro Controller Based technology
• Inbuit C.T.
• Indicates phase –phase voltage
• Indicates system current
• Indication for phase through high bright LED
• Voltage indiaction rotate at fixed interval for different phase-phase
• Panel mountable
te c h n i c a l s P e c i f i c at i o n s:• Aux. Supply : 415 +/- 20 % VAC
• Amp. Range : 4-40 Amp, 10-100 Amp
a P P l i c at i o n:Control Panels for housing, water pumps, industries,
residential complex etc.
PANEL METERS
(10.11.1) | AUTOPHOTO
Type AMPR PHASE APPLICATION
ALC – 6 ( I ) 1 6 Amp 1 Phase Indoor application
ALC – 10 ( I ) 1 10 Amp 1 Phase Indoor application
ALC – 10 ( O ) 1 10 Amp 1 Phase Indoor application
ALC – 25 ( I ) 1 25 Amp 1 Phase Indoor application
ALC – 25 ( O ) 1 25 Amp 1 Phase Indoor application
ALC – 16 ( O ) 3 16 Amp 1 Phase Indoor application
ALC – 32 ( O ) 3 32 Amp 1 Phase Indoor application
ALC – 63 ( O ) 3 63 Amp 1 Phase Indoor application
AUTOMATIC LIGHT CONTROLLER
28 29
SPP WITH WATER LEVEL GUARD
(10.12.1) | SWG
sa l i e n t fe at u R e s :• Phase failure relay with dry run protection ( with Prod)
• Voltage sensing unit
• Over voltage protection
• Under voltage protection
• Engineering grade plastic (HIPS) enclosure
• Panel mountable
• Available with S.S. Sensor.
te c h n i c a l s P e c i f i c at i o n s:• Aux Supply: 415 +/- 20 % VAC, 50 Hz
• Output : 1 C/O , 6Amp @ 230 AC (Resi.)
• Over voltage: Above 480 VAC
• Under voltage : Below 320 VAC
a P P l i c at i o n:MCC for sewage pumps
(10.13.1) | LLC-101
sa l i e n t fe at u R e s :• Easy to install• DIN rail/ Panel mountable• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Specially for three phase motor starters• Availabe with S.S Sensors/Magnetic sensors/Float switch• Engineering grade plastic enclosure(ABS)
te c h n i c a l s P e c i f i c at i o n s:• System Voltage: 415 VAC +/- 20 % , 50 Hz• Output : 1 CO contact ,1 Amp. At 415 VAC, Pf=0.5
a P P l i c at i o n:MCC of water pump in hotels, housed, high rise towers,
societies, industries, commercial complexes, municipal water stations.
(10.13.2) | LLC-2
sa l i e n t fe at u R e s :• Easy to install• Panel mountable• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Specially for single phase motor starters• Availabe with S.S Sensors/Magnetic sensors/Float switch• Engineering grade plastic enclosure(ABS)
te c h n i c a l s P e c i f i c at i o n s:• System Voltage: 230 VAC +/- 20 %, 50 Hz• Output Voltage: 230 VAC +/- 20 %, 50 Hz• Capacity 30 A at 230 VAC ( Resi.)
a P P l i c at i o n:MCC of water pump in hotels, housed, high rise towers, societies,
industries, commercial complexes, municipal water stations.
WATER LEVEL CONTROLLER
30 31
(10.13.3) | LLC-2S
sa l i e n t fe at u R e s :• Easy to install• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Specially for single phase submersible semi automatic
motor starters• Availabe with S.S Sensors/Magnetic sensors/Float switch• Engineering grade plastic enclosure(ABS)
te c h n i c a l s P e c i f i c at i o n s:• System Voltage: 230 VAC +/- 20 % , 50 Hz• Output Voltage: 230 VAC+/- 20 %, 50 Hz
Capacity 30 A at 230 VAC ( Resi.)
a P P l i c at i o n:MCC of water pump in hotels, housed, high rise towers, societies,
industries, commercial complexes, municipal water stations.
(10.13.4) | LLC-001/LLC-001D
sa l i e n t fe at u R e s :• Water Level controller adopter• Usefull with GELCO make single or three phase DOL or• FASD starters having adopter facility only• Easy to install• Panel mountable• Two tank controller• Automatic control of starter according to set water level in tanks• LED indications for water level in tank• Availabe with S.S Sensors/Magnetic sensors/Float switch• Engineering grade plastic enclosure (ABS)• For GELCO starter having micro controller based technology use
LLC-001 D
a P P l i c at i o n:Motor starter of water pump in hotels, housed, high rise
towers, societies, industries, commercial complexes,
municipal water stations.
WATER LEVEL CONTROLLER