Industries

BenefitsSingle Source AccountabilityPre-Packaged Modular Design Costs Less Than Component Based Site-Built Systems Reducing Overall Project CostMinimizes Field Erection Time -Shorter Overall Project Delivery ScheduleComplete System Function TestingPrior To Shipment24/7 Customer Service

Industry StandardsVessels Code Stamped ASME Section VIII &National Board RegisteredPiping Designed to ANSI B31.1/ANSI B31.3Pipe Fabrication to ASME Section IXStructural Steel Assembly Designed to AWS D1.1API 14C for Offshore Applications

Standard FeaturesProcess Validation/Guarantee Using “Aspen Plus”Simulation SoftwareASME Scrubbers/Separators/Coalescers/FiltersINTEGRAHEATTM Electric Process Heaters

INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068

FGCS-100.0

Integrated Flow Solutions Fuel Gas Conditioning Systems aredesigned to protect natural gas fueled engines and turbinesfrom liquid slugs, solids (<0.1 microns) and liquid aerosols.Additionally, the fuel gas is superheated above the hydrocarbonand water dew points to prevent liquid condensation in theturbine’s combustion chambers. These systems meet or exceedreciprocating engine and turbine manufacturers’ fuel gas qualityspecifications providing dry, clean fuel to increase the life of theequipment.

Fuel GasConditioningSystems

GENERALPOWER OIL & GAS

Standard Features (Continued)TEMA Shell & Tube ExchangersClass 1, Div. 2 Hazardous LocationsLocal Control Panel

Optional FeaturesLadder and Platfrom for Vertical Filter AccessMichellTM Instruments Hydrocarbon and WaterDewpoint Measurement and ControlIEC/CENELEC/CSA Compliant Control Panel,Conduit and WiringPLC Control System with Data HighwayNACE MR-01-75 Latest Edition for Sour ServicePneumatic Pressure Test After Re-AssemblyThird Party Inspection by ABS, Lloyd’s and DNVCompliance with Plant/Engineering Specifications

Standard DesignsPower

Frame Size Gas TurbinesAero-Derivative Size Gas Turbines

Oil & GasCross Exchanger Design That Recovers HeatLoss From Pressure Drops

Additional ServicesInstallation/Training/Start-Up SupervisionExtended Equipment WarrantiesNationwide Service Network

www.IFSolutions.com

www.IFSolutions.com

Fuel Gas Conditioning Systems

INTEGRATED FLOW SOLUTIONS 9807 Whithorn Drive Houston, TX 77095 281-855-8125 / Toll-Free USA 800-795-4068LIT FGCS-100.0 03042004 IFS These materials contain proprietary information and may not be reproduced without prior written permission from Integrated Flow Solutions.

FLOWRATEMMSCFD LENGTH - X WIDTH - Y HEIGHT - Z WEIGHT - LBS.

35 20’ 15’ 16’ 60,00025 18’ 12’ 16’ 57,50015 17’ 12’ 14’ 55,00010 16’ 12’ 14’ 52,5005 15’ 10’ 14’ 50,000

Oil & GasFLOWRATEMMSCFD LENGTH - X WIDTH - Y HEIGHT - Z WEIGHT - LBS.

60 40’ 12’ 12’ 50,00030 35’ 12’ 12’ 40,00020 25’ 12’ 12’ 30,00010 15’ 8’ 12’ 15,000

Power