fuel gas conditioning systems

Post on 03-Jan-2016

109 Views

Category:

Documents

7 Downloads

Preview:

Click to see full reader

DESCRIPTION

Fuel Gas Conditioning Systems. Wide Variety. From Pipeline. To Turbine. Cleaning Stages Knockout Fine Filtration Last Chance Filter Pressure Reduction Flow Metering Heating. From the Pipeline to the Turbine. Leaves the Pipe Line 700 – 1000 psig 7 lb/ mmSCF 30-90 °F - PowerPoint PPT Presentation

TRANSCRIPT

Fuel Gas Conditioning Systems

Fuel Gas Conditioning Systems

Wide Variety

From Pipeline

To Turbine

• Cleaning Stages– Knockout– Fine Filtration– Last Chance Filter

• Pressure Reduction

• Flow Metering

• Heating

From the Pipeline to the Turbine

Fuel Gas Specifics

Leaves the Pipe LineLeaves the Pipe Line• 700 – 1000 psig• 7 lb/ mmSCF• 30-90 °F• Aerosols and Particulate

Enters the TurbineEnters the Turbine• 350-450 psig• 7 lb/ mmSCF• Up to 350 °F• Free from Aerosols and

Particulate

Fuel Gas Composition• Sweet:

– Typical Natural Gas– Does not contain

significant amounts of H2S or CO2

• Sour:– High H2S Content

– Highly Corrosive– NACE

Typical Fuel Gas Composition

Component Mol %

Methane 95.513

Ethane 2.45

Propane 0.506

N-Butane 0.1

I-Butane 0.11

N-Pentane 0.022

I-Pentane 0.036

Neo-Pentane 0.0

Hexane+ 0.054

Oxygen 0.0

Carbon Dioxide 0.853

Nitrogen 0.356

Maximum Total Sulfur

0.0

Knockout (Scrubber)• Primary Filtration• Gross Liquid and/or Solid Removal• Mechanical Separation

– Vanes – impingement– Multi Cyclones – centrifugal force

Knockout Accessories

• Drain Tank• Level Indicator• Level Switches• Automatic Drain Valve• Relief Valve• Pressure Gage• Differential Pressure

Pressure Reduction

• Sliding Stem Valves with Positioners

• Reduces the pressure of the gas from 700-1000 psi to 400-450 psi

• Protects Turbine• Improves Turbine

Efficiency

Fine Filtration

• Filter Separators– 99% 0.5 – 3 micron

• Coalescer– 99.98% of .3 μm

• Solids and Liquids• Dual Filters• < 3 psi Drop Clean

Filter Accessories

• Ladder and Platform• Isolation Valves• Level Indicator• Level Switches• Automatic Drain Valve• Relief Valve• Pressure Gage• Differential Pressure

Performance Heater• Shell and Tube Heat

Exchanger– 100% of Gas Flow– Heats Gas to ~350 °

• Boiler Feed Water• Controlled by Throttling

Water Discharge

Start-Up Heater

• Electric Heater– ~25% of Gas Flow– 50 F Temperature Rise

• 50 F Above Dew Point• SCR or Step Control

Water Bath Heater• Gas Fired Heater

– 100% of Gas Flow– Heats Gas to ~180 °

• U-Bend• Controlled by Throttling

Gas Flow/Bypass

Detection Tank

• Mechanical Separator – Multi-Cyclone

• Capture Water from Heat Exchanger Leak

• Instruments– Level Switches– Level Gages– Level Transmitters

Flow Metering

• Custody Transfer– Not Clark-Reliance

• Individual Turbine Flow Measurement

• Orifice Meter

Last Chance Filter

• Final Stage of Protection for Turbine

• Coalescing Filter• 99.98% Removal

of .3 μm particles• Level Instruments• Manual Drain• Differential Pressure

Sales Opportunity - Filtration

• Filter Vessels – Anderson Product– AMCS– AVGS– ACF

• Elements• Aftermarket

Sales Opportunity - Instrumentation• Jerguson

– Level Gages– Mag Gages– Level Switches

• Other – Pressure Gages– Differential

Pressure– Temperature

Gages

SIEMENS – EVANDER ANDREWS

• Scope– Vane

Separator– Coalescer– Drain Tank– Level

Controls– Piping– Valves– Junction Box

CALPINE – OTAY MESA

• Scope– Electric Startup Heater with SCR Control Panel– Performance Heat Exchanger

•Vane Separator

•Coalescing Filter

•Piping•Valves

•Drain Tank

JANTESA – SANTA ROSA

• Scope– Unit Skids– Electric Heater– Heat Exchanger– Coalescing

Filters– Automatic

Valves– Piping– Junction Box

UE – TRACY STATION

• Scope– Vane Separator– Pressure Reducing

Valves– Flow Measurement– Piping and Valves– Water Bath Heater

• ETI

UE – NRG – CEDAR BAYOU• Performance Heaters• Startup Heaters with

SCR Control Panels

• Coalescing Filters• Multi-Cyclones• Instrumentation

Conclusion

• Fuel Gas Filtration equipment controls – Temperature– Pressure– Contaminant

• A variety of setups are used to manage a variety of situations

top related