ge healthcare 3d tee bruce bollen, md missoula anesthesiology international heart institute of...

Post on 19-Jan-2016

214 Views

Category:

Documents

2 Downloads

Preview:

Click to see full reader

TRANSCRIPT

GE Healthcare 3D TEE

Bruce Bollen, MDMissoula Anesthesiology

International Heart Institute of MontanaMissoula, Montana

Dr. Bollen 2015

SCA Echo WeekMarch 23-27, 2015

Atlanta, GA

Dr. Bollen 2015

GE Vivid 3D TEE Probe

Over 2,000 piezo crystals in transducer Allows simultaneous 2D biplane imaging Allows simultaneous 2D tri-plane

imaging Designed for acquisition of 3D matrix

volumes Probe programmable for preferred views Designed for flexibility ease of use

Dr. Bollen 2015

Matrix Array 2D Utilization

Tri-plane: 3 simultaneous 2D images to be obtained– With and without color– May set the image TEE rotational angle

• Allows simultaneous ME 4ch, ME 2ch, ME LAX

Bi-Plane: Two 2D orthogonal simultaneous views.– Allows second orthogonal plane to be defined

on first plane image– Second plane able to steer/adjust– With and without color

Dr. Bollen 2015

GE Matrix Biplane Imaging (X-plane)

Dr. Bollen 2015

GE Matrix Triplane Imaging

Dr. Bollen 2015

GE 3D Mitral Valve: En Fosse View

Dr. Bollen 2015

GE 3D Matrix Analysis:Designed for Ease of Use

Allows 4D analysis of matrix array set data– 3D view orientation

• ME slices• ME align

– Multi Plane Reconstruction (MPR) options• Flexi slice• Multi slice

Multiple Matrix Array Cropping options– 2 Click crop (similar to Tom Tec D’Art)– Crop Tool: Cropping by color plane

Specialized MV analysis program LV and RV Analysis packet

Dr. Bollen 2015

GE 3D Provide ME Slices: Instant Mid Esophageal Slicing

Dr. Bollen 2015

GE 3D Provides ME Align: allows custom alignment of centroid, and change slice angle alignment around centroid

Dr. Bollen 2015

ME Align: Note slice angles around centroid have been modified

Dr. Bollen 2015

Flexi Slice: 2D Multi Planar Reconstruction

Allows three 2D plane cropping boxes of 3D matrix data set

Allows for measurements

Dr. Bollen 2015

Flexi-Slice of Mitral Valve

Dr. Bollen 2015

Flexi Slice: Allows image rotation to the view you want, allows plane manipulation

Dr. Bollen 2015

Flexi Slice allows orientation by crop box color square, and red dot localization

Dr. Bollen 2015

Flexi Slice allows 2D measurements

Dr. Bollen 2015

GE Multi Slice applied to Mitral Valve

Dr. Bollen 2015

GE Multi Slice applied to LV

Dr. Bollen 2015

GE 2 Click Crop for matrix views orientation (similar to d’Aart)

Dr. Bollen 2015

GE 2 Click Crop focusing on LVOT

Dr. Bollen 2015

GE allows Crop Box Cropping

Dr. Bollen 2015

GE MV Analysis: Uses Tom Tec Program

Dr. Bollen 2015

GE MV Analysis: Uses Tom Tec Program

Dr. Bollen 2015

GE MV analysis allows application of measurements

Dr. Bollen 2015

GE has LV and RV Analysis

Dr. Bollen 2015

GE Post Procedure Analysis

Centricity-GE’s overall imaging storage system for CT, MRI, Cath, and echo

Utilizes advanced applications for CT, MRI Can utilizes GE Echo Pack Applications GE Echo Pack for those hospitals without

Centricity

top related