Caledonian Railway Cables
www.caledonian-cables.co.uk www.addison-cables.com
TRACTION CABLES & HIGH TEMPERATURECABLES FOR RAILWAY APPLICATION
Caledonian & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in its 2 plants in UK and 5 plants in China. Caledonian products are sold in more than 35 countries around the globe.
Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market.
Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured.
Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian has established an extensive network of design, manufacturing, and logistics facilities in the world's major markets to serve the growing outsourcing needs of both multinational and regional customers.
Caledonian & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in its 2 plants in UK and 5 plants in China. Caledonian products are sold in more than 35 countries around the globe.
Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market.
Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured.
Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian has established an extensive network of design, manufacturing, and logistics facilities in the world's major markets to serve the growing outsourcing needs of both multinational and regional customers.
www.caledonian-cables.co.uk www.addison-cables.com
ww
w.caledonian-cables.co.uk
COMPANY PROFILE
GKW-RW 300/500V Thin Wall Single Core …………………………………………………………… 1
GKW-RW/S 300/500V Thin Wall Multicore …………………………………………………………… 3
GKW-RW/S EMC 300/500V Thin Wall Screened Multicore ………………………………………… 7
3GKW-RW 0.6/1KV Thin Wall Single Core ………………………………………………………… 10
3GKW-RW/S 0.6/1KV Thin Wall Multicore ………………………………………………………… 12
3GKW-RW/S EMC 0.6/1KV Thin Wall Screened Multicore ……………………………………… 14
3GKW-MW 0.6/1KV Medium Wall Single Core …………………………………………………… 16
3GKW-MW EMC 0.6/1KV Medium Wall Screened Single Core ………………………………… 18
3GKW-MW/S 0.6/1KV Medium Wall Multicore ……………………………………………………… 20
3GKW-MW/S EMC 0.6/1KV Medium Wall Screened Multicore …………………………………… 24
3GKW-DW 0.6/1KV Dual Wall Single Core ………………………………………………………… 28
3GKW-DW/S 0.6/1KV Dual Wall Multicore ………………………………………………………… 30
3GKW-DW/S EMC 0.6/1KV Dual Wall Screened Multicore ……………………………………… 32
4GKW-AXplus-DW 1.8/3KV Dual Wall Single Core ………………………………………………… 36
4GKW-AXplus-DW EMC 1.8/3KV Dual Wall Screened Single Core …………………………… 38
4GKW-AXplus-DW/S EMC 1.8/3KV Dual Wall Screened Multicore ……………………………… 40
TRACTION CABLES FOR RAILWAY APPLICATION
CONTENT
Caledonian Railway Cables
www.caledonian-cables.co.uk
9GKW-AXplus-DW 3.6/6KV Dual Wall Single Core ………………………………………………… 42
9GKW-AXplus-DW EMC 3.6/6KV Dual Wall Screened Single Core …………………………… 44
GKW-RW FE180 300/500V Thin Wall Single Core ………………………………………………… 46
3GKW-MW FE180 0.6/1KV Medium Wall Single Core …………………………………………… 48
4GKW-AXplus-DW FE180 1.8/3KV Dual Wall Single Core ……………………………………… 50
HIGH TEMPERATURE CABLES FOR RAILWAY APPLICATION
ORDERING INFORMATION
FRA 145 Single Core ………………………………………………………………………………… 52
FRA 145/S Multicore …………………………………………………………………………………… 54
FRA 145/S EMC Screened Multicore ………………………………………………………………… 59
FRA 155 Single Core ………………………………………………………………………………… 63
FRA 155S Oil Resistant Single Core ………………………………………………………………… 65
FRA 155/S Multicore …………………………………………………………………………………… 67
FRA 155/S EMC Screened Multicore ………………………………………………………………… 69
Ordering Information For GKW Cables ……………………………………………………………… 71
Ordering Information For High Temperature Cables ……………………………………………… 72
Caledonian Railway Cables
1TRACTION CABLES
Caledonian Railway Cables
1
TRACTION CABLES
TRACTION CABLESTRACTION CABLES
GKW-RW 300/500V Thin Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation
TRACTION CABLES
www.addison-cables.com
www.caledonian-cables.co.uk
2
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
1×0.5 16/0.20 0.18 1.3 61×0.75 24/0.20 0.18 1.56 91×1.0 32/0.20 0.18 1.7 121×1.5 30/0.25 0.22 2.04 171×2.5 50/0.25 0.28 2.66 27
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Soldering HeatResistant
Cold Resistant
Caledonian Railway Cables
3
TRACTION CABLES
TRACTION CABLES
GKW-RW/S 300/500V Thin Wall Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Electron Beam Crosslinkable LSZH Insulation
www.addison-cables.com
www.caledonian-cables.co.uk
4
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×0.5 16/0.20 0.18 4.5 293×0.5 16/0.20 0.18 4.6 364×0.5 16/0.20 0.18 5.0 445×0.5 16/0.20 0.18 5.4 526×0.5 16/0.20 0.18 5.9 597×0.5 16/0.20 0.18 6.4 718×0.5 16/0.20 0.18 6.8 819×0.5 16/0.20 0.18 7.1 81
10×0.5 16/0.20 0.18 7.3 8812×0.5 16/0.20 0.18 7.5 10114×0.5 16/0.20 0.18 7.9 11516×0.5 16/0.20 0.18 8.3 12818×0.5 16/0.20 0.18 8.8 14419×0.5 16/0.20 0.18 8.8 14820×0.5 16/0.20 0.18 9.3 16124×0.5 16/0.20 0.18 10.2 18127×0.5 16/0.20 0.18 10.6 20036×0.5 16/0.20 0.18 11.9 26148×0.5 16/0.20 0.18 13.5 3372×0.75 24/0.20 0.18 4.8 373×0.75 24/0.20 0.18 5.1 484×0.75 24/0.20 0.18 5.6 585×0.75 24/0.20 0.18 6.1 696×0.75 24/0.20 0.18 6.7 817×0.75 24/0.20 0.18 7.1 938×0.75 24/0.20 0.18 7.7 1089×0.75 24/0.20 0.18 8.1 108
10×0.75 24/0.20 0.18 8.3 11812×0.75 24/0.20 0.18 8.6 13714×0.75 24/0.20 0.18 9.0 15616×0.75 24/0.20 0.18 9.5 17518×0.75 24/0.20 0.18 10.0 19819×0.75 24/0.20 0.18 10.1 20220×0.75 24/0.20 0.18 10.5 21924×0.75 24/0.20 0.18 11.7 24827×0.75 24/0.20 0.18 12.2 27536×0.75 24/0.20 0.18 13.7 36248×0.75 24/0.20 0.18 15.5 4682×1.0 32/0.20 0.18 5.2 453×1.0 32/0.20 0.18 5.5 594×1.0 32/0.20 0.18 6.2 73
Caledonian Railway Cables
5
TRACTION CABLES
TRACTION CABLES
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
5×1.0 32/0.20 0.18 6.7 876×1.0 32/0.20 0.18 7.3 1027×1.0 32/0.20 0.18 7.9 1198×1.0 32/0.20 0.18 8.4 1359×1.0 32/0.20 0.18 8.9 137
10×1.0 32/0.20 0.18 9.1 15012×1.0 32/0.20 0.18 9.4 17414×1.0 32/0.20 0.18 9.9 19916×1.0 32/0.20 0.18 10.4 22318×1.0 32/0.20 0.18 11.0 25419×1.0 32/0.20 0.18 11.1 25920×1.0 32/0.20 0.18 11.7 28224×1.0 32/0.20 0.18 12.9 31927×1.0 32/0.20 0.18 13.4 35436×1.0 32/0.20 0.18 15.1 46748×1.0 32/0.20 0.18 17.2 6072×1.5 30/0.25 0.22 6.0 593×1.5 30/0.25 0.22 6.4 814×1.5 30/0.25 0.22 7.1 995×1.5 30/0.25 0.22 7.7 1236×1.5 30/0.25 0.22 8.5 1437×1.5 30/0.25 0.22 9.1 1638×1.5 30/0.25 0.22 9.8 1889×1.5 30/0.25 0.22 10.5 189
10×1.5 30/0.25 0.22 10.7 21512×1.5 30/0.25 0.22 11.1 24414×1.5 30/0.25 0.22 11.7 27916×1.5 30/0.25 0.22 12.3 32618×1.5 30/0.25 0.22 13.0 35819×1.5 30/0.25 0.22 13.1 36620×1.5 30/0.25 0.22 13.7 39624×1.5 30/0.25 0.22 15.3 45027×1.5 30/0.25 0.22 15.9 50136×1.5 30/0.25 0.22 17.9 66337×1.5 30/0.25 0.22 18.5 71948×1.5 30/0.25 0.22 20.5 8642×2.5 50/0.25 0.28 7.1 893×2.5 50/0.25 0.28 7.4 1174×2.5 50/0.25 0.28 8.3 1505×2.5 50/0.25 0.28 9.1 1826×2.5 50/0.25 0.28 9.9 2097×2.5 50/0.25 0.28 10.8 2468×2.5 50/0.25 0.28 11.7 2859×2.5 50/0.25 0.28 12.5 286
www.addison-cables.com
www.caledonian-cables.co.uk
6
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
10×2.5 50/0.25 0.28 12.7 31812×2.5 50/0.25 0.28 13.1 37214×2.5 50/0.25 0.28 13.9 42816×2.5 50/0.25 0.28 14.7 48318×2.5 50/0.25 0.28 15.2 53819×2.5 50/0.25 0.28 15.5 56520×2.5 50/0.25 0.28 16.4 61224×2.5 50/0.25 0.28 18.3 69527×2.5 50/0.25 0.28 18.9 77636×2.5 50/0.25 0.28 21.3 103048×2.5 50/0.25 0.28 24.5 1347
Soldering HeatResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant AbrasionResistant
Corona Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant Low TemperatureResistant
Caledonian Railway Cables
7
TRACTION CABLES
TRACTION CABLES
GKW-RW/S EMC 300/500V Thin Wall Screened Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Copper Wire Screen
Electron Beam Crosslinkable LSZH Insulation
www.addison-cables.com
www.caledonian-cables.co.uk
8
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×0.5 16/0.20 0.18 4.8 313×0.5 16/0.20 0.18 5.0 434×0.5 16/0.20 0.18 5.4 505×0.5 16/0.20 0.18 6.1 586×0.5 16/0.20 0.18 6.5 777×0.5 16/0.20 0.18 7.0 818×0.5 16/0.20 0.18 7.4 919×0.5 16/0.20 0.18 7.7 93
10×0.5 16/0.20 0.18 7.7 9712×0.5 16/0.20 0.18 8.1 11314×0.5 16/0.20 0.18 8.5 12616×0.5 16/0.20 0.18 8.7 14018×0.5 16/0.20 0.18 9.4 15622×0.5 16/0.20 0.18 10.3 19224×0.5 16/0.20 0.18 10.6 19827×0.5 16/0.20 0.18 11.1 23836×0.5 16/0.20 0.18 12.3 28248×0.5 16/0.20 0.18 13.9 362
2×2×0.5 16/0.20 0.18 7.1 893×2×0.5 16/0.20 0.18 7.5 1034×2×0.5 16/0.20 0.18 8.2 1302×0.75 24/0.20 0.18 5.3 463×0.75 24/0.20 0.18 5.6 554×0.75 24/0.20 0.18 6.2 635×0.75 24/0.20 0.18 6.7 776×0.75 24/0.20 0.18 7.4 907×0.75 24/0.20 0.18 7.7 1038×0.75 24/0.20 0.18 8.3 1209×0.75 24/0.20 0.18 8.7 122
10×0.75 24/0.20 0.18 8.7 12912×0.75 24/0.20 0.18 9.3 14914×0.75 24/0.20 0.18 9.6 16816×0.75 24/0.20 0.18 9.8 18718×0.75 24/0.20 0.18 10.7 21322×0.75 24/0.20 0.18 11.7 25924×0.75 24/0.20 0.18 12.1 26927×0.75 24/0.20 0.18 12.6 29736×0.75 24/0.20 0.18 14.1 387
2×2×0.75 24/0.20 0.18 8.0 1006×2×0.75 24/0.20 0.18 11.6 202
2×1.0 32/0.20 0.18 5.9 633×1.0 32/0.20 0.18 6.2 754×1.0 32/0.20 0.18 6.8 895×1.0 32/0.20 0.18 7.3 108
Caledonian Railway Cables
9
TRACTION CABLES
TRACTION CABLES
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
6×1.0 32/0.20 0.18 7.9 1147×1.0 32/0.20 0.18 8.5 1298×1.0 32/0.20 0.18 9.0 1469×1.0 32/0.20 0.18 9.5 15210×1.0 32/0.20 0.18 9.5 16112×1.0 32/0.20 0.18 10.0 20924×1.0 32/0.20 0.18 13.3 34227×1.0 32/0.20 0.18 13.8 37836×1.0 32/0.20 0.18 15.7 515
2×2×1.0 32/0.20 0.18 8.9 1162×1.5 30/0.25 0.22 6.7 803×1.5 30/0.25 0.22 7.1 984×1.5 30/0.25 0.22 7.6 1185×1.5 30/0.25 0.22 8.3 1276×1.5 30/0.25 0.22 9.1 1517×1.5 30/0.25 0.22 9.7 1758×1.5 30/0.25 0.22 10.4 2019×1.5 30/0.25 0.22 11.1 211
10×1.5 30/0.25 0.22 11.1 22512×1.5 30/0.25 0.22 11.7 28524×1.5 30/0.25 0.22 15.9 49927×1.5 30/0.25 0.22 16.5 55236×1.5 30/0.25 0.22 18.5 7202×2.5 50/0.25 0.28 7.7 983×2.5 50/0.25 0.28 8.1 1204×2.5 50/0.25 0.28 8.9 1505×2.5 50/0.25 0.28 9.7 1856×1.5 50/0.25 0.28 10.5 2207×2.5 50/0.25 0.28 11.4 2618×2.5 50/0.25 0.28 12.3 2999×2.5 50/0.25 0.28 13.1 30910×2.5 50/0.25 0.28 13.1 33112×2.5 50/0.25 0.28 13.7 38624×2.5 50/0.25 0.28 18.9 75527×2.5 50/0.25 0.28 19.5 83736×2.5 50/0.25 0.28 21.9 1100
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
10
3GKW-RW 0.6/1KV Thin Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.6 0.75 1 1.2 1.5 2.0 2.5 3 4.0AWG 20 18 16 14 12Maximum Conductor Resistance Ω/km 40.1 31.1 26.7 20.0 15.5 13.7 10.5 8.21 6.56 5.09Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway Cables
11
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×0.5 19/0.18 16/0.20 0.3 1.40 61×0.6 19/0.20 0.3 1.50 7
1×0.75 19/0.22 24/0.20 0.3 1.60 8.31×1.0 19/0.25 32/0.20 0.3 1.75 111×1.2 19/0.29 0.3 2.00 131×1.5 19/0.31 30/0.25 0.3 2.15 161×2.0 37/0.25 0.4 2.40 191×2.5 19/0.40 50/0.25 0.4 2.75 261×4 56/0.30 0.4 3.35 40
Highly Flexible UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant
Acid and AlkaliResistant
Soldering HeatResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
12
3GKW-RW/S 0.6/1KV Thin Wall Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway Cables
13
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
2×0.5 19/0.18 16/0.20 0.3 4.4 293×0.5 19/0.18 16/0.20 0.3 4.6 364×0.5 19/0.18 16/0.20 0.3 5.0 445×0.5 19/0.18 16/0.20 0.3 5.5 526×0.5 19/0.18 16/0.20 0.3 6.0 62
2×2×0.5 19/0.18 16/0.20 0.3 6.5 584×2×0.5 19/0.18 16/0.20 0.3 8.7 992×0.75 19/0.22 24/0.20 0.3 4.75 353×0.75 19/0.22 24/0.20 0.3 5.2 484×0.75 19/0.22 24/0.20 0.3 5.6 586×0.75 19/0.22 24/0.20 0.3 6.75 83
2×2×0.75 19/0.22 24/0.20 0.3 7.75 812×1.0 19/0.25 32/0.20 0.3 5.1 453×1.0 19/0.25 32/0.20 0.3 5.4 544×1.0 19/0.25 32/0.20 0.3 5.8 646×1.0 19/0.25 32/0.20 0.3 7.3 98
10×1.0 19/0.25 32/0.20 0.3 8.7 15025×1.0 19/0.25 32/0.20 0.3 12.8 3242×1.5 19/0.31 30/0.25 0.3 6.0 633×1.5 19/0.31 30/0.25 0.3 6.3 764×1.5 19/0.31 30/0.25 0.3 6.9 945×1.5 19/0.31 30/0.25 0.3 7.8 1206×1.5 19/0.31 30/0.25 0.3 8.5 1417G1.5 19/0.31 30/0.25 0.3 9.1 1658×1.5 19/0.31 30/0.25 0.3 10.3 201
10×1.5 19/0.31 30/0.25 0.3 10.6 21618×1.5 19/0.31 30/0.25 0.3 13.4 35825G1.5 19/0.31 30/0.25 0.3 15.5 4942×2.5 19/0.40 50/0.25 0.4 7.3 983×2.5 19/0.40 50/0.25 0.4 7.8 1224×2.5 19/0.40 50/0.25 0.4 8.7 1475×2.5 19/0.40 50/0.25 0.4 9.4 1806×2.5 19/0.40 50/0.25 0.4 10.6 223
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
14
3GKW-RW/S EMC 0.6/1KV Thin Wall Screened Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Copper Wire Screen
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway Cables
15
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
2×0.5 19/0.18 16/0.20 0.3 4.8 423×0.5 19/0.18 16/0.20 0.3 5.3 514×0.5 19/0.18 16/0.20 0.3 5.4 566×0.5 19/0.18 16/0.20 0.3 6.5 82
15×0.5 19/0.18 16/0.20 0.3 9.0 1672×2×0.5 19/0.18 16/0.20 0.3 7.2 803×2×0.5 19/0.18 16/0.20 0.3 8.1 984×2×0.5 19/0.18 16/0.20 0.3 9.3 131
12×2×0.5 19/0.18 16/0.20 0.3 13.0 2762×0.75 19/0.22 24/0.20 0.3 5.0 484×0.75 19/0.22 24/0.20 0.3 6.0 726×0.75 19/0.22 24/0.20 0.3 7.2 103
10×0.75 19/0.22 24/0.20 0.3 8.7 15218×0.75 19/0.22 24/0.20 0.3 11.0 244
3×2×0.75 19/0.22 24/0.20 0.3 9.0 1272×1.0 19/0.25 32/0.20 0.3 5.6 603×1.0 19/0.25 32/0.20 0.3 6.0 764×1.0 19/0.25 32/0.20 0.3 6.5 886×1.0 19/0.25 32/0.20 0.3 7.8 1148×1.0 19/0.25 32/0.20 0.3 8.9 171
25×1.0 19/0.25 32/0.20 0.3 13.8 3922×2×1.0 19/0.25 32/0.20 0.3 8.3 117
2×1.5 19/0.31 30/0.25 0.3 6.5 863×1.5 19/0.31 30/0.25 0.3 6.8 954×1.5 19/0.31 30/0.25 0.3 7.4 1186×1.5 19/0.31 30/0.25 0.3 9.0 168
18×1.5 19/0.31 30/0.25 0.3 14.4 4522×2.5 19/0.40 50/0.25 0.4 7.8 1226×2.5 19/0.40 50/0.25 0.4 11.4 268
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
16
3GKW-MW 0.6/1KV Medium Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5 4.0 6.0 10 16 25 35Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565Voltage Rating KV 0.6/1
Nominal Conductor Cross Section mm² 50 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.393 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway Cables
17
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×0.5 19/0.18 16/0.20 0.5 2.0 81×0.75 24/0.20 0.5 2.2 111×1.0 32/0.20 0.55 2.45 141×1.5 30/0.25 0.55 2.7 201×2.5 50/0.25 0.6 3.3 311×4 56/0.30 0.65 3.95 451×6 84/0.30 0.7 4.7 69
1×10 80/0.40 0.8 5.85 1131×16 119/0.41 126/0.40 0.9 7.3 1561×25 182/0.41 196/0.40 1.0 8.9 2501×35 266/0.41 276/0.40 1.1 10.2 3301×50 378/0.41 396/0.40 1.2 11.9 5001×70 348/0.51 360/0.50 1.3 14.3 6901×95 444/0.51 475/0.50 1.4 15.9 883
1×120 551/0.51 608/0.50 1.5 17.9 11801×150 722/0.51 756/0.50 1.6 20.3 14601×185 874/0.51 925/0.50 1.7 22.0 17801×240 1147/0.51 1221/0.50 1.9 25.2 22201×300 1443/0.51 1525/0.50 2.0 28.0 30001×400 2016/0.51 2013/0.50 2.2 33.8 4000
Highly Flexible UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant
Acid and AlkaliResistant
Soldering HeatResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
18
3GKW-MW EMC 0.6/1KV Medium Wall Screened Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors : C i rcu la r C lass 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating KV 0.6/1
Nominal Conductor Cross Section mm² 25 35 50 70 95 120 150 185Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.164 0.132 0.108Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation
Electron Beam Crosslinkable LSZH Sheath
Copper Wire Screen
Caledonian Railway Cables
19
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×0.5 19/0.18 16/0.20 0.5 4.0 261×0.75 24/0.20 0.5 4.2 301×1.0 32/0.20 0.55 4.5 341×1.5 30/0.25 0.55 4.8 431×2.5 50/0.25 0.6 5.5 611×4 56/0.30 0.65 6.15 841×6 84/0.30 0.7 7.0 112
1×10 80/0.40 0.8 8.4 1701×16 119/0.41 126/0.40 0.9 10.2 2501×25 182/0.41 196/0.40 1.0 12.2 3601×35 266/0.41 276/0.40 1.1 13.7 4901×50 378/0.41 396/0.40 1.2 15.7 6901×70 348/0.51 360/0.50 1.3 18.7 9201×95 444/0.51 475/0.50 1.4 20.5 1170
1×120 551/0.51 608/0.50 1.5 22.7 14301×150 722/0.51 756/0.50 1.6 25.5 18301×185 874/0.51 925/0.50 1.7 27.6 2190
高柔软 抗紫外线
NF C32-070-2.2(C1)IEC 60332-3/EN50266
阻燃(成束)
Zero
无卤IEC 60754-1/NF C20-454
EN 50267-2-1
耐冲击
阻燃(单根)NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
低腐蚀性 低毒 低烟IEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902防矿物油
耐臭氧
耐酸碱腐蚀
耐焊接热耐冷
www.addison-cables.com
www.caledonian-cables.co.uk
20
3GKW-MW/S 0.6/1KV Medium Wall Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5 4.0 6.0 10 16 25 35Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway Cables
21
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
2×0.5 19/0.18 16/0.20 0.5 5.9 393×0.5 19/0.18 16/0.20 0.5 6.1 504×0.5 19/0.18 16/0.20 0.5 7.0 555×0.5 19/0.18 16/0.20 0.5 7.3 746×0.5 19/0.18 16/0.20 0.5 7.5 857×0.5 19/0.18 16/0.20 0.5 9.1 998×0.5 19/0.18 16/0.20 0.5 9.3 1119×0.5 19/0.18 16/0.20 0.5 9.5 114
10×0.5 19/0.18 16/0.20 0.5 9.5 12212×0.5 19/0.18 16/0.20 0.5 10.0 14514×0.5 19/0.18 16/0.20 0.5 10.5 16316×0.5 19/0.18 16/0.20 0.5 11.2 18518×0.5 19/0.18 16/0.20 0.5 12.7 20520×0.5 19/0.18 16/0.20 0.5 13.0 23324×0.5 19/0.18 16/0.20 0.5 13.9 26427×0.5 19/0.18 16/0.20 0.5 14.5 29536×0.5 19/0.18 16/0.20 0.5 16.3 38648×0.5 19/0.18 16/0.20 0.5 19.0 5162×0.75 19/0.21 24/0.20 0.5 6.0 493×0.75 19/0.21 24/0.20 0.5 6.8 634×0.75 19/0.21 24/0.20 0.5 6.9 775×0.75 19/0.21 24/0.20 0.5 8.4 966×0.75 19/0.21 24/0.20 0.5 8.7 1077×0.75 19/0.21 24/0.20 0.5 9.1 1318×0.75 19/0.21 24/0.20 0.5 10.9 1479×0.75 19/0.21 24/0.20 0.5 11.3 15210×0.75 19/0.21 24/0.20 0.5 11.6 16212×0.75 19/0.21 24/0.20 0.5 11.9 17514×0.75 19/0.21 24/0.20 0.5 12.1 21316×0.75 19/0.21 24/0.20 0.5 12.4 24120×0.75 19/0.21 24/0.20 0.5 15.2 32524×0.75 19/0.21 24/0.20 0.5 15.6 34927×0.75 19/0.21 24/0.20 0.5 16.1 38536×0.75 19/0.21 24/0.20 0.5 18.1 50548×0.75 19/0.21 24/0.20 0.5 21.2 6782×1.0 32/0.20 0.55 6.4 593×1.0 32/0.20 0.55 6.8 784×1.0 32/0.20 0.55 7.4 935×1.0 32/0.20 0.55 8.3 1156×1.0 32/0.20 0.55 10.0 1307×1.0 32/0.20 0.55 10.3 1588×1.0 32/0.20 0.55 10.7 1819×1.0 32/0.20 0.55 12.5 20010×1.0 32/0.20 0.55 12.7 21012×1.0 32/0.20 0.55 12.9 234
www.addison-cables.com
www.caledonian-cables.co.uk
22
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
14×1.0 32/0.20 0.55 13.2 26516×1.0 32/0.20 0.55 13.5 30020×1.0 32/0.20 0.55 14.7 37724×1.0 32/0.20 0.55 16.9 43325×1.0 32/0.20 0.55 18.7 51927×1.0 32/0.20 0.55 19.0 60036×1.0 32/0.20 0.55 19.9 64448×1.0 32/0.20 0.55 22.9 8372×1.5 30/0.25 0.55 7.5 753×1.5 30/0.25 0.55 8.0 964×1.5 30/0.25 0.55 8.3 1205×1.5 30/0.25 0.55 10.2 1466×1.5 30/0.25 0.55 11.6 1737×1.5 30/0.25 0.55 12.1 1858×1.5 30/0.25 0.55 12.5 2079×1.5 30/0.25 0.55 12.9 21010×1.5 30/0.25 0.55 13.3 23612×1.5 30/0.25 0.55 14.2 30514×1.5 30/0.25 0.55 14.6 34616×1.5 30/0.25 0.55 15.0 39320×1.5 30/0.25 0.55 16.5 50024×1.5 30/0.25 0.55 19.1 58227×1.5 30/0.25 0.55 19.7 64436×1.5 30/0.25 0.55 23.0 90548×1.5 30/0.25 0.55 25.7 11202×2.5 50/0.25 0.6 8.5 1153×2.5 50/0.25 0.6 8.9 1494×2.5 50/0.25 0.6 9.9 1835×2.5 50/0.25 0.6 11.1 2286×2.5 50/0.25 0.6 12.1 2657×2.5 50/0.25 0.6 13.0 3098×2.5 50/0.25 0.6 14.3 3609×2.5 50/0.25 0.6 15.4 36610×2.5 50/0.25 0.6 15.1 40012×2.5 50/0.25 0.6 15.9 46714×2.5 50/0.25 0.6 16.5 53216×2.5 50/0.25 0.6 17.5 60020×2.5 50/0.25 0.6 20.1 77724×2.5 50/0.25 0.6 21.4 87327×2.5 50/0.25 0.6 22.5 972
2×4 56/0.30 0.65 9.5 1513×4 56/0.30 0.65 10.2 2074×4 56/0.30 0.65 11.3 2615×4 56/0.30 0.65 12.6 3246×4 56/0.30 0.65 13.9 3797×4 56/0.30 0.65 15.2 4338×4 56/0.30 0.65 16.3 5189×4 56/0.30 0.65 17.5 550
Caledonian Railway Cables
23
TRACTION CABLES
TRACTION CABLES
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
10×4 56/0.30 0.65 17.7 58112×4 56/0.30 0.65 18.3 67514×4 56/0.30 0.65 19.2 78516×4 56/0.30 0.65 20.4 88620×4 56/0.30 0.65 23.0 112924×4 56/0.30 0.65 24.7 127627×4 56/0.30 0.65 26.1 14352×6 84/0.30 0.7 10.7 2053×6 84/0.30 0.7 11.4 2794×6 84/0.30 0.7 12.6 3535×6 84/0.30 0.7 14.0 4366×6 84/0.30 0.7 15.7 5017×6 84/0.30 0.7 17.2 5972×10 80/0.40 0.8 12.8 3133×10 80/0.40 0.8 13.7 4334×10 80/0.40 0.8 15.4 5145×10 80/0.40 0.8 17.0 6416×10 80/0.40 0.8 19.1 7947×10 80/0.40 0.8 20.7 9192×16 119/0.40 126/0.40 0.9 16.5 4823×16 119/0.40 126/0.40 0.9 17.6 5904×16 119/0.40 126/0.40 0.9 19.8 7875×16 119/0.40 126/0.40 0.9 22.1 9926×16 119/0.40 126/0.40 0.9 24.3 11927×16 119/0.40 126/0.40 0.9 26.5 14092×25 182/0.40 196/0.40 1.0 19.9 7163×25 182/0.40 196/0.40 1.0 21.4 8994×25 182/0.40 196/0.40 1.0 23.8 11825×25 182/0.40 196/0.40 1.0 26.4 14826×25 182/0.40 196/0.40 1.0 29.9 18187×25 182/0.40 196/0.40 1.0 32.1 21282×35 266/0.40 276/0.40 1.1 22.3 7753×35 266/0.40 276/0.40 1.1 24.0 9384×35 266/0.40 276/0.40 1.1 26.7 12305×35 266/0.40 276/0.40 1.1 29.6 15436×35 266/0.40 276/0.40 1.1 33.3 18907×35 266/0.40 276/0.40 1.1 36.7 2263
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
24
3GKW-MW/S EMC 0.6/1KV Medium Wall Screened Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Copper Wire Screen
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway Cables
25
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
2×0.5 19/0.18 16/0.20 0.5 6.6 683×0.5 19/0.18 16/0.20 0.5 6.9 754×0.5 19/0.18 16/0.20 0.5 7.5 815×0.5 19/0.18 16/0.20 0.5 8.2 936×0.5 19/0.18 16/0.20 0.5 8.8 1117×0.5 19/0.18 16/0.20 0.5 9.8 1258×0.5 19/0.18 16/0.20 0.5 10.3 1439×0.5 19/0.18 16/0.20 0.5 10.8 149
10×0.5 19/0.18 16/0.20 0.5 11.0 15412×0.5 19/0.18 16/0.20 0.5 12.3 17514×0.5 19/0.18 16/0.20 0.5 13.0 19815×0.5 19/0.18 16/0.20 0.5 13.4 21016×0.5 19/0.18 16/0.20 0.5 13.7 22320×0.5 19/0.18 16/0.20 0.5 14.0 27424×0.5 19/0.18 16/0.20 0.5 14.2 31027×0.5 19/0.18 16/0.20 0.5 14.5 343
9×2×0.5 19/0.18 16/0.20 0.5 20.6 5402×0.75 19/0.21 24/0.20 0.5 7.2 803×0.75 19/0.21 24/0.20 0.5 7.5 904×0.75 19/0.21 24/0.20 0.5 8.3 1165×0.75 19/0.21 24/0.20 0.5 9.1 1336×0.75 19/0.21 24/0.20 0.5 9.9 1657×0.75 19/0.21 24/0.20 0.5 10.7 1868×0.75 19/0.21 24/0.20 0.5 11.5 1949×0.75 19/0.21 24/0.20 0.5 12.3 220
10×0.75 19/0.21 24/0.20 0.5 12.6 25012×0.75 19/0.21 24/0.20 0.5 13.2 27814×0.75 19/0.21 24/0.20 0.5 13.8 30016×0.75 19/0.21 24/0.20 0.5 14.4 34820×0.75 19/0.21 24/0.20 0.5 14.5 35424×0.75 19/0.21 24/0.20 0.5 15.6 40127×0.75 19/0.21 24/0.20 0.5 16.3 459
5×2×0.75 19/0.21 24/0.20 0.5 16.0 3502×1.0 32/0.20 0.55 7.4 933×1.0 32/0.20 0.55 8.1 1144×1.0 32/0.20 0.55 8.8 1405×1.0 32/0.20 0.55 9.8 1586×1.0 32/0.20 0.55 10.8 1707×1.0 32/0.20 0.55 11.8 1898×1.0 32/0.20 0.55 11.8 2199×1.0 32/0.20 0.55 12.0 223
10×1.0 32/0.20 0.55 12.2 234
www.addison-cables.com
www.caledonian-cables.co.uk
26
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
12×1.0 32/0.20 0.55 12.5 26814×1.0 32/0.20 0.55 13.2 30516×1.0 32/0.20 0.55 13.9 33920×1.0 32/0.20 0.55 15.6 43024×1.0 32/0.20 0.55 17.1 51127×1.0 32/0.20 0.55 17.7 5602×1.5 30/0.25 0.55 8.1 1143×1.5 30/0.25 0.55 8.6 1244×1.5 30/0.25 0.55 9.9 1395×1.5 30/0.25 0.55 10.9 1506×1.5 30/0.25 0.55 11.7 1737×1.5 30/0.25 0.55 13.2 2038×1.5 30/0.25 0.55 14.6 2439×1.5 30/0.25 0.55 14.9 274
10×1.5 30/0.25 0.55 15.5 29912×1.5 30/0.25 0.55 16.2 34214×1.5 30/0.25 0.55 16.8 39016×1.5 30/0.25 0.55 17.5 56020×1.5 30/0.25 0.55 17.6 61424×1.5 30/0.25 0.55 19.3 67027×1.5 30/0.25 0.55 19.9 734
6×2×1.5 30/0.25 0.55 18.9 5402×2.5 50/0.25 0.6 9.6 1603×2.5 50/0.25 0.6 10.5 2004×2.5 50/0.25 0.6 11.3 2205×2.5 50/0.25 0.6 12.7 2506×2.5 50/0.25 0.6 13.7 3457×2.5 50/0.25 0.6 14.8 4008×2.5 50/0.25 0.6 14.9 4109×2.5 50/0.25 0.6 16.0 437
10×2.5 50/0.25 0.6 16.0 46112×2.5 50/0.25 0.6 16.8 53114×2.5 50/0.25 0.6 17.7 60116×2.5 50/0.25 0.6 19.0 69120×2.5 50/0.25 0.6 23.3 96924×2.5 50/0.25 0.6 23.5 100427×2.5 50/0.25 0.6 24.0 1104
2×4 56/0.30 0.65 10.8 2163×4 56/0.30 0.65 11.8 2604×4 56/0.30 0.65 13.3 3455×4 56/0.30 0.65 14.7 4405×4 56/0.30 0.65 14.7 4605×4 56/0.30 0.65 15.7 4855×4 56/0.30 0.65 17.2 5845×4 56/0.30 0.65 18.3 605
Caledonian Railway Cables
27
TRACTION CABLES
TRACTION CABLES
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
5×4 56/0.30 0.65 18.3 64112×4 56/0.30 0.65 19.5 7602×6 84/0.30 0.7 12.1 2913×6 84/0.30 0.7 13.8 3704×6 84/0.30 0.7 16.3 4585×6 84/0.30 0.7 17.4 6206×6 84/0.30 0.7 17.4 6407×6 84/0.30 0.7 17.8 6738×6 84/0.30 0.7 19.4 7749×6 84/0.30 0.7 20.7 820
10×6 84/0.30 0.7 20.7 87512×6 84/0.30 0.7 21.8 10262×10 80/0.40 0.8 14.3 4323×10 80/0.40 0.8 17.1 5804×10 80/0.40 0.8 19.2 7505×10 80/0.40 0.8 21.1 8506×10 80/0.40 0.8 21.9 8757×10 80/0.40 0.8 22.8 10198×10 80/0.40 0.8 23.7 11902×16 119/0.40 126/0.40 0.9 18.2 6603×16 119/0.40 126/0.40 0.9 20.5 8204×16 119/0.40 126/0.40 0.9 20.4 8745×16 119/0.40 126/0.40 0.9 22.7 10836×16 119/0.40 126/0.40 0.9 24.9 12947×16 119/0.40 126/0.40 0.9 27.1 15218×16 119/0.40 126/0.40 0.9 29.6 18082×25 182/0.40 196/0.40 1.0 22.9 9903×25 182/0.40 196/0.40 1.0 24.4 10754×25 182/0.40 196/0.40 1.0 25.2 14045×25 182/0.40 196/0.40 1.0 27.0 17503×35 266/0.40 276/0.40 1.1 27.9 16006×35 266/0.40 276/0.40 1.1 39.7 33502×50 378/0.40 396/0.40 1.2 29.8 1760
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
28
3GKW-DW 0.6/1KV Dual Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.6 0.75 1 1.2 1.5 2.0 2.5 3 4.0AWG 20 18 16 14 12Maximum Conductor Resistance Ω/km 40.1 31.1 26.7 20.0 15.5 13.7 10.5 8.21 6.56 5.09Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation2
Electron Beam Crosslinkable LSZH Insulation1
Caledonian Railway Cables
29
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×0.5 19/0.18 16/0.20 0.2 1.3 5.51×0.6 19/0.20 0.2 1.39 6.5
1×0.75 19/0.22 24/0.20 0.2 1.52 81×1.0 19/0.25 32/0.20 0.2 1.67 101×1.2 19/0.28 0.2 1.83 121×1.5 19/0.31 30/0.25 0.3 2.04 151×2.0 37/0.25 0.3 2.29 191×2.5 19/0.40 50/0.25 0.3 2.54 241×3 37/0.32 0.3 2.78 291×4 56/0.30 0.4 3.21 39
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
30
3GKW-DW/S 0.6/1KV Dual Wall Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Electron Beam Crosslinkable LSZH Insulation2
Electron Beam Crosslinkable LSZH Insulation1
Soldering HeatResistant
Low TemperatureResistant
Highly FlexibleNF C32-070-2.2(C1)
IEC 60332-3/EN50266
Fire RetardantImpact Resistant Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low CorrosivityCold Resistant
Caledonian Railway Cables
31
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
2×0.5 19/0.18 16/0.20 0.2 4.0 243×0.5 19/0.18 16/0.20 0.2 4.2 305×0.5 19/0.18 16/0.20 0.2 5.0 436×0.5 19/0.18 16/0.20 0.2 5.4 519×0.5 19/0.18 16/0.20 0.2 6.7 6412×0.5 19/0.18 16/0.20 0.2 6.9 8916×0.5 19/0.18 16/0.20 0.2 7.8 11525×0.5 19/0.18 16/0.20 0.2 9.5 17030×0.5 19/0.18 16/0.20 0.2 10.1 204
2×2×0.5 19/0.18 16/0.20 0.2 5.8 502×0.75 19/0.22 24/0.20 0.2 4.4 324×0.75 19/0.22 24/0.20 0.2 5.0 499×0.75 19/0.22 24/0.20 0.2 7.7 10614×0.75 19/0.22 24/0.20 0.2 8.4 14027×0.75 19/0.22 24/0.20 0.2 11.3 26836×0.75 19/0.22 24/0.20 0.2 12.8 360
3×1.0 19/0.25 32/0.20 0.2 5.0 454×1.0 19/0.25 32/0.20 0.2 5.5 606×1.0 19/0.25 32/0.20 0.2 6.6 8812×1.0 19/0.25 32/0.20 0.2 8.6 16014×1.0 19/0.25 32/0.20 0.2 9.1 17420×1.0 19/0.25 32/0.20 0.2 11.2 25550×1.0 19/0.25 32/0.20 0.2 16.8 6202×1.5 37/0.22 30/0.25 0.3 5.4 555×1.5 37/0.22 30/0.25 0.3 7.1 1107×1.5 37/0.22 30/0.25 0.3 8.4 15010×1.5 37/0.22 30/0.25 0.3 9.9 17016×1.5 37/0.22 30/0.25 0.3 11.7 31018×1.5 37/0.22 30/0.25 0.3 12.4 35024×1.5 37/0.22 30/0.25 0.3 14.4 45030×1.5 37/0.22 30/0.25 0.3 15.6 56050×1.5 37/0.22 30/0.25 0.3 20.1 8683×2.5 37/0.29 50/0.25 0.3 7.0 1056×2.5 37/0.29 50/0.25 0.3 9.6 20012×2.5 37/0.29 50/0.25 0.3 12.6 36018×2.5 37/0.29 50/0.25 0.3 15.3 54524×2.5 37/0.29 50/0.25 0.3 17.8 69527×2.5 37/0.29 50/0.25 0.3 18.2 78030×2.5 37/0.29 50/0.25 0.3 19.3 87036×2.5 37/0.29 50/0.25 0.3 21.0 1050
UV ResistantIRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
AbrasionResistant
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
www.addison-cables.com
www.caledonian-cables.co.uk
32
3GKW-DW/S EMC 0.6/1KV Dual Wall Screened Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 88.5 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Electron Beam Crosslinkable LSZH Insulation2Copper Wire Screen
Electron Beam Crosslinkable LSZH Insulation1
Caledonian Railway Cables
33
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
2×2×0.25 19/0.13 0.2 5.7 483×2×0.25 19/0.13 0.2 6.1 574×2×0.25 19/0.13 0.2 7.0 727×2×0.25 19/0.13 0.2 7.8 9225×0.25 19/0.13 0.2 8.9 1392×0.5 19/0.18 16/0.20 0.2 4.3 343×0.5 19/0.18 16/0.20 0.2 4.5 404×0.5 19/0.18 16/0.20 0.2 4.8 475×0.5 19/0.18 16/0.20 0.2 5.4 586×0.5 19/0.18 16/0.20 0.2 5.9 707×0.5 19/0.18 16/0.20 0.2 6.3 808×0.5 19/0.18 16/0.20 0.2 6.8 869×0.5 19/0.18 16/0.20 0.2 7.2 95
10×0.5 19/0.18 16/0.20 0.2 7.2 10112×0.5 19/0.18 16/0.20 0.2 7.4 11015×0.5 19/0.18 16/0.20 0.2 8.5 13516×0.5 19/0.18 16/0.20 0.2 8.5 14218×0.5 19/0.18 16/0.20 0.2 8.9 16220×0.5 19/0.18 16/0.20 0.2 9.3 18322×0.5 19/0.18 16/0.20 0.2 9.9 19525×0.5 19/0.18 16/0.20 0.2 10.3 21327×0.5 19/0.18 16/0.20 0.2 10.5 23130×0.5 19/0.18 16/0.20 0.2 11.3 26536×0.5 19/0.18 16/0.20 0.2 12.1 30142×0.5 19/0.18 16/0.20 0.2 12.9 35948×0.5 19/0.18 16/0.20 0.2 13.6 41050×0.5 19/0.18 16/0.20 0.2 14.2 430
2×2×0.5 19/0.18 16/0.20 0.2 6.4 693×2×0.5 19/0.18 16/0.20 0.2 6.7 804×2×0.5 19/0.18 16/0.20 0.2 7.4 955×2×0.5 19/0.18 16/0.20 0.2 9.2 1366×2×0.5 19/0.18 16/0.20 0.2 9.2 1488×2×0.5 19/0.18 16/0.20 0.2 9.7 155
10×2×0.5 19/0.18 16/0.20 0.2 10.9 20012×2×0.5 19/0.18 16/0.20 0.2 12.1 23915×2×0.5 19/0.18 16/0.20 0.2 13.0 30016×2×0.5 19/0.18 16/0.20 0.2 13.0 32020×2×0.5 19/0.18 16/0.20 0.2 14.4 3602×3×0.5 19/0.18 16/0.20 0.2 7.3 902×0.75 19/0.22 24/0.20 0.2 4.8 403×0.75 19/0.22 24/0.20 0.2 5.0 504×0.75 19/0.22 24/0.20 0.2 5.5 62
www.addison-cables.com
www.caledonian-cables.co.uk
34
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
5×0.75 19/0.22 24/0.20 0.2 6.1 756×0.75 19/0.22 24/0.20 0.2 6.6 857×0.75 19/0.22 24/0.20 0.2 7.2 1008×0.75 19/0.22 24/0.20 0.2 7.7 113
10×0.75 19/0.22 24/0.20 0.2 8.1 13012×0.75 19/0.22 24/0.20 0.2 8.4 15014×0.75 19/0.22 24/0.20 0.2 9.1 16916×0.75 19/0.22 24/0.20 0.2 9.7 20618×0.75 19/0.22 24/0.20 0.2 10.1 23020×0.75 19/0.22 24/0.20 0.2 11.1 25624×0.75 19/0.22 24/0.20 0.2 12.0 29425×0.75 19/0.22 24/0.20 0.2 12.3 300
2×2×0.75 19/0.22 24/0.20 0.2 7.1 853×2×0.75 19/0.22 24/0.20 0.2 7.6 1094×2×0.75 19/0.22 24/0.20 0.2 9.9 1435×2×0.75 19/0.22 24/0.20 0.2 10.7 1826×2×0.75 19/0.22 24/0.20 0.2 11.9 2267×2×0.75 19/0.22 24/0.20 0.2 13.2 2798×2×0.75 19/0.22 24/0.20 0.2 13.4 291
10×2×0.75 19/0.22 24/0.20 0.2 14.8 3333×3×0.75 19/0.22 24/0.20 0.2 8.9 1515×4×0.75 19/0.22 24/0.20 0.2 12.8 288
2×1.0 19/0.25 32/0.20 0.2 5.0 503×1.0 19/0.25 32/0.20 0.2 5.5 604×1.0 19/0.25 32/0.20 0.2 5.8 725×1.0 19/0.25 32/0.20 0.2 6.6 886×1.0 19/0.25 32/0.20 0.2 7.3 1147×1.0 19/0.25 32/0.20 0.2 7.9 1338×1.0 19/0.25 32/0.20 0.2 8.5 1509×1.0 19/0.25 32/0.20 0.2 8.9 160
10×1.0 19/0.25 32/0.20 0.2 8.9 16812×1.0 19/0.25 32/0.20 0.2 9.2 18816×1.0 19/0.25 32/0.20 0.2 10.5 25018×1.0 19/0.25 32/0.20 0.2 11.2 27525×1.0 19/0.25 32/0.20 0.2 12.7 35527×1.0 19/0.25 32/0.20 0.2 13.3 39530×1.0 19/0.25 32/0.20 0.2 13.8 45036×1.0 19/0.25 32/0.20 0.2 15.1 53042×1.0 19/0.25 32/0.20 0.2 16.3 60450×1.0 19/0.25 32/0.20 0.2 17.8 690
2×2×1.0 19/0.25 32/0.20 0.2 7.8 1074×2×1.0 19/0.25 32/0.20 0.2 9.4 1286×2×1.0 19/0.25 32/0.20 0.2 11.6 239
12×2×1.0 19/0.25 32/0.20 0.2 14.3 400
Caledonian Railway Cables
35
TRACTION CABLES
TRACTION CABLES
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
4×3×1.0 19/0.25 32/0.20 0.2 11.5 2303×4×1.0 19/0.25 32/0.20 0.2 11.3 2454×4×1.0 19/0.25 32/0.20 0.2 12.5 265
2×1.5 37/0.22 30/0.25 0.3 5.8 703×1.5 37/0.22 30/0.25 0.3 6.1 814×1.5 37/0.22 30/0.25 0.3 6.7 1005×1.5 37/0.22 30/0.25 0.3 7.7 1346×1.5 37/0.22 30/0.25 0.3 8.3 1537×1.5 37/0.22 30/0.25 0.3 9.1 1848×1.5 37/0.22 30/0.25 0.3 10.3 2229×1.5 37/0.22 30/0.25 0.3 10.5 234
10×1.5 37/0.22 30/0.25 0.3 10.5 24012×1.5 37/0.22 30/0.25 0.3 10.9 26816×1.5 37/0.22 30/0.25 0.3 12.5 36418×1.5 37/0.22 30/0.25 0.3 13.2 40525×1.5 37/0.22 30/0.25 0.3 15.8 56248×1.5 37/0.22 30/0.25 0.3 20.7 988
2×2×1.5 37/0.22 30/0.25 0.3 9.2 1533×2×1.5 37/0.22 30/0.25 0.3 9.8 2057×2×1.5 37/0.22 30/0.25 0.3 12.6 330
2×2.5 37/0.29 50/0.25 0.3 7.0 1053×2.5 37/0.29 50/0.25 0.3 7.6 1304×2.5 37/0.29 50/0.25 0.3 8.4 1705×2.5 37/0.29 50/0.25 0.3 9.4 1906×2.5 37/0.29 50/0.25 0.3 10.3 2257×2.5 37/0.29 50/0.25 0.3 11.4 2708×2.5 37/0.29 50/0.25 0.3 12.6 343
10×2.5 37/0.29 50/0.25 0.3 13.2 37012×2.5 37/0.29 50/0.25 0.3 13.6 42016×2.5 37/0.29 50/0.25 0.3 15.6 56018×2.5 37/0.29 50/0.25 0.3 16.6 62025×2.5 37/0.29 50/0.25 0.3 19.3 83427×2.5 37/0.29 50/0.25 0.3 20.5 87048×2.5 37/0.29 50/0.25 0.3 25.6 1560
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
36
4GKW-AXplus-DW 1.8/3KV Dual Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 1.8/3.0
Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 1.8/3.0
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (for flexible installation)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation2
Electron Beam Crosslinkable LSZH Insulation1
Caledonian Railway Cables
37
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×1.0 32/0.20 0.7 2.8 171×1.5 30/0.25 0.8 3.2 231×2.0 37/0.26 0.8 3.55 281×2.5 50/0.25 0.9 3.75 341×4.0 56/0.30 1.0 4.5 531×6.0 84/0.30 1.1 5.1 741×10 80/0.40 1.2 6.35 1181×16 119/0.41 126/0.40 1.5 8.3 1801×25 182/0.41 196/0.40 1.8 10.2 2741×35 266/0.41 276/0.40 2.0 11.7 3791×50 378/0.41 396/0.40 2.2 13.6 5501×70 348/0.51 360/0.50 2.1 15.6 7301×95 444/0.51 475/0.50 2.3 17.3 940
1×120 551/0.51 608/0.50 2.4 19.6 11801×150 722/0.51 756/0.50 2.6 21.9 15101×185 874/0.51 925/0.50 2.8 23.8 18021×240 1147/0.51 1221/0.50 2.9 26.9 22901×300 1443/0.51 1525/0.50 3.0 29.7 29281×400 2016/0.51 2013/0.50 3.4 35.8 4040
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
38
4GKW-AXplus-DW EMC 1.8/3KV Dual Wall Screened Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 1.8/3
Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 1.8/3
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation2Electron Beam Crosslinkable LSZH Insulation1
Electron Beam Crosslinkable LSZH SheathCopper Wire Screen
Caledonian Railway Cables
39
TRACTION CABLES
TRACTION CABLES
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×1.0 32/0.20 0.7 4.6 381×1.5 30/0.25 0.8 5.2 471×2.5 50/0.25 0.9 5.8 631×4 56/0.30 1.0 6.7 891×6 84/0.30 1.1 7.4 1231×10 80/0.40 1.2 9.0 1781×16 119/0.41 126/0.40 1.5 11.2 2801×25 182/0.41 196/0.40 1.8 13.4 3711×35 266/0.41 276/0.40 2.0 14.8 4921×50 378/0.41 396/0.40 2.2 16.8 6931×70 348/0.51 360/0.50 2.1 19.0 9131×95 444/0.51 475/0.50 2.3 20.7 11601×120 551/0.51 608/0.50 2.4 23.4 14411×150 722/0.51 756/0.50 2.6 25.9 17301×185 874/0.52 925/0.50 2.8 27.8 20881×240 1147/0.51 1221/0.50 2.9 31.2 29081×300 1443/0.51 1525/0.50 3.0 34.2 33751×400 1887/0.50 2013/0.50 3.4 37.1 4250
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
40
4GKW-AXplus-DW/S EMC 1.8/3KV Dual Wall Screened Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 10 16 25 35Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 1.95 1.24 0.795 0.565Voltage Rating KV 1.8/3
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Electron Beam Crosslinkable LSZH Insulation2Copper Wire Screen
Electron Beam Crosslinkable LSZH Insulation1
Caledonian Railway Cables
41
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
2×1.5 30/0.25 0.8 9.2 1353×1.5 30/0.25 0.8 10.0 1646×1.5 30/0.25 0.8 13.8 3153×2.5 50/0.25 0.9 11.4 2254×4 56/0.30 1.0 15.4 427
3×10 80/0.40 1.2 18.2 6483×16 119/0.40 126/0.40 1.5 23.1 9003×25 182/0.40 196/0.40 1.8 28.4 15204×25 182/0.40 196/0.40 1.8 34.1 18692×35 266/0.40 276/0.40 2.0 29.8 15803×35 266/0.40 276/0.40 2.0 31.6 19704×35 266/0.40 276/0.40 2.0 37.0 2102
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
42
9GKW-AXplus-DW 3.6/6KV Dual Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 3.6/6
Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 3.6/6
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation2
Electron Beam Crosslinkable LSZH Insulation1
Caledonian Railway Cables
43
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×1.5 30/0.25 1.3 4.4 341×2.5 50/0.25 1.4 4.9 471×4 56/0.30 1.5 5.7 681×6 84/0.30 1.5 6.3 88
1×10 80/0.40 1.5 7.5 1401×16 119/0.41 126/0.40 1.7 9.4 2051×25 182/0.41 196/0.40 1.8 11.0 2971×35 266/0.41 276/0.40 2.0 12.5 4101×50 378/0.41 396/0.40 2.3 14.5 5701×70 348/0.51 360/0.50 2.2 16.5 7601×95 444/0.51 475/0.50 2.5 18.5 980
1×120 551/0.51 608/0.50 2.7 20.8 12361×150 722/0.51 756/0.50 2.8 23.1 15701×185 874/0.51 925/0.50 3.0 25.0 18481×240 1147/0.51 1221/0.50 3.1 28.0 24001×300 1443/0.51 1525/0.50 3.1 30.9 29701×400 2016/0.51 2013/0.50 3.3 36.5 4090
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
44
9GKW-AXplus-DW EMC 3.6/6KV Dual Wall Screened Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 3.6/6
Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 3.6/6
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation2Electron Beam Crosslinkable LSZH Insulation1
Electron Beam Crosslinkable LSZH SheathCopper Wire Screen
Caledonian Railway Cables
45
TRACTION CABLES
TRACTION CABLES
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×1.5 30/0.25 1.3 6.6 721×2.5 50/0.25 1.4 7.2 891×4 56/0.30 1.5 8.2 1191×6 84/0.30 1.5 9.1 150
1×10 80/0.40 1.5 10.4 2201×16 119/0.41 126/0.40 1.7 12.4 3301×25 182/0.41 196/0.40 1.8 14.3 3901×35 266/0.41 276/0.40 2.0 15.7 5501×50 378/0.41 396/0.40 2.3 17.7 7331×70 348/0.51 360/0.50 2.2 20.0 9701×95 444/0.51 475/0.50 2.5 22.0 12161×120 551/0.51 608/0.50 2.7 24.7 15101×150 722/0.51 756/0.50 2.8 27.1 19001×185 874/0.51 925/0.50 3.0 29.1 21951×240 1147/0.51 1221/0.50 3.1 32.3 28301×300 1443/0.51 1525/0.50 3.1 35.6 35201×400 2016/0.51 2013/0.50 3.3 38.3 4364
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
46
GKW-RW FE180 300/500V Thin Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Flame Barrier: MICA tape.• Insulation: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation
MICA Tape
Caledonian Railway Cables
47
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×0.5 19/0.18 16/0.20 0.3 2.00 81×0.75 19/0.21 24/0.20 0.3 2.25 101×1.0 32/0.20 0.35 2.50 141×1.5 30/0.25 0.35 2.80 181×2.5 50/0.25 0.35 3.20 29
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Soldering HeatResistant
Cold Resistant
V
FE
InsulationIntegrity FE180
EN 50200/IEC 60331/NF C32-070-2.3(CR1)
www.addison-cables.com
www.caledonian-cables.co.uk
48
3GKW-MW FE180 0.6/1KV Medium Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Flame Barrier: MICA tape.• Insulation: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating KV 0.6/1
Nominal Conductor Cross Section mm² 25 35 50 70 95 150Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.132Voltage Rating KV 0.6/1
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Insulation
MICA Tape
Caledonian Railway Cables
49
TRACTION CABLES
TRACTION CABLES
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×1.0 32/0.20 0.55 3.15 191×1.5 30/0.25 0.55 3.40 241×2.5 50/0.25 0.60 4.05 36.61×4 56/0.30 0.65 4.60 52.51×6 84/0.30 0.70 5.30 731×10 80/0.40 0.80 6.35 1221×16 119/0.41 126/0.40 0.90 8.15 1821×25 182/0.41 196/0.40 1.0 9.65 2631×35 266/0.41 276/0.40 1.1 10.80 3651×50 378/0.41 396/0.40 1.2 12.80 5301×70 348/0.51 360/0.50 1.3 15.10 7301×95 444/0.51 475/0.50 1.4 17.00 930
1×150 722/0.51 756/0.50 1.6 21.30 1450
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Soldering HeatResistant
Cold Resistant
V
FE
InsulationIntegrity FE180
EN 50200/IEC 60331/NF C32-070-2.3(CR1)
www.addison-cables.com
www.caledonian-cables.co.uk
50
4GKW-AXplus-DW FE180 1.8/3KV Dual Wall Single Core
º Applications
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Flame Barrier: MICA tape.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 1.8/3.0
Nominal Conductor Cross Section mm² 70 95 120 150 185 240Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817Voltage Rating KV 1.8/3.0
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
MICA Tape
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway Cables
51
TRACTION CABLES
TRACTION CABLES
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No/mm
Nominal Insulation Thickness
mm
Nominal Overall
Diametermm
Nominal Weightkg/km
1×1.5 30/0.25 1.05 4.90 381×2.5 50/0.25 1.15 5.35 501×4 56/0.30 1.25 6.10 881×6 84/0.30 1.30 7.00 93
1×10 80/0.40 1.30 8.10 1421×16 119/0.41 126/0.40 1.15 9.30 2101×25 182/0.41 196/0.40 1.50 10.8 2901×35 266/0.41 276/0.40 1.50 12.1 4001×50 378/0.41 396/0.40 1.60 13.8 5611×70 348/0.51 360/0.50 1.70 16.2 7601×95 444/0.51 475/0.50 1.90 18.0 980
1×120 551/0.51 608/0.50 1.60 20.2 12121×150 722/0.51 756/0.50 2.20 22.7 15201×185 874/0.51 925/0.50 2.40 24.6 18301×240 1147/0.51 1221/0.50 2.50 27.6 2411
Soldering HeatResistant
Low TemperatureResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire RetardantIRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
AbrasionResistant
Corona ResistantFlame Retardant
NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1
EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity
Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant
Acid and AlkaliResistant
Cold Resistant
V
FE
InsulationIntegrity FE180
EN 50200/IEC 60331/NF C32-070-2.3(CR1)
www.addison-cables.com
www.caledonian-cables.co.uk
52
FRA 145 Single Core
º Applications
Single core cable with improved fire performance and very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for laying in tubes, surface wiring, direct in plaster or underneath it, as well in conduits.
º Standard
• IEC 60754-1, EN 50267-2-1 (halogen free)• IEC 60754-2, EN 50267-2-2 (no corrosive gases)• NES 02-713, NFC 20-454 (no toxic gases)• IEC 61034, EN 50268-2 (low smoke density)• IEC60332-1,EN50265-2-1(flameretardant)• IEC 60332-3, EN 50266-2, NF C 32-070
(non-flamepropagating)• DIN51900(lowfireload)
º Construction
• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Colour Code: Various colours on request.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 85.9 57.2 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)
Nominal Conductor Cross Section mm² 25 35 50 70 95 120 150 185 240 300Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable
Polyolefine Copolymer Insulation
Caledonian Railway Cables
53
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+145℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
1×0.25 19/0.13 0.5 1.5 51×0.34 19/0.16 0.5 1.7 61×0.50 19/0.18 0.5 1.9 81×0.75 24/0.20 0.6 2.2 111×1.0 32/0.20 0.6 2.5 141×1.5 30/0.25 0.6 3.0 211×2.5 48/0.25 0.7 3.7 331×4.0 56/0.30 0.8 4.2 481×6.0 81/0.30 0.9 4.7 67
1×10.0 78/0.40 1.0 6.1 1121×16.0 119/0.40 1.1 7.5 1721×25.0 182/0.40 1.3 9.0 2621×35.0 266/0.40 1.3 10.1 3621×50.0 378/0.40 1.6 12.7 5121×70.0 348/0.50 1.6 14.7 7101×95.0 444/0.50 1.8 16.4 937
1×120.0 551/0.50 1.8 18.2 11591×150.0 722/0.50 1.9 20.9 14471×185.0 874/0.50 2.0 22.9 17901×240.0 1147/0.50 2.2 25.8 23181×300.0 1443/0.50 2.4 28.3 2897
Highly Flexible UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
Weather Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
www.addison-cables.com
www.caledonian-cables.co.uk
54
FRA 145/S Multicore
º Applications
Multicore cable with improved fire performance and very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.
º Standard
• IEC 60754-1, EN 50267-2-1 (halogen free)• IEC 60754-2, EN 50267-2-2 (no corrosive gases)• NES 02-713, NFC 20-454 (no toxic gases)• IEC 61034, EN 50268-2 (low smoke density)• IEC60332-1,EN50265-2-1(flameretardant)• IEC 60332-3, EN 50266-2, NF C 32-070
(non-flamepropagating)• DIN51900(lowfireload)
º Construction
• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation: Electronbeamcrosslinkablepolyolefinecopolymer.• Sheath:Electronbeamcrosslinkablepolyolefinecopolymer.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.50 0.75 1.0 1.5 2.5 4.0 6.0Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)
Nominal Conductor Cross Section mm² 10 16 25 35 50 70 95Maximum Conductor Resistance Ω/km 1.95 1.24 0.795 0.565 0.393 0.277 0.21Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable Polyolefine Copolymer Sheath
Electron Beam Crosslinkable Polyolefine Copolymer Insulation
Caledonian Railway Cables
55
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+145℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×0.5 19/0.18 0.5 5.1 383G0.5 19/0.18 0.5 5.5 46
4×(G)0.5 19/0.18 0.5 5.9 555G0.5 19/0.18 0.5 6.7 686G0.5 19/0.18 0.5 7.1 777G0.5 19/0.18 0.5 7.8 938G0.5 19/0.18 0.5 8.6 10210G0.5 19/0.18 0.5 9.4 13012G0.5 19/0.18 0.5 9.4 12514G0.5 19/0.18 0.5 10.0 14516G0.5 19/0.18 0.5 10.7 1662×0.75 24/0.20 0.6 5.9 523G0.75 24/0.20 0.6 6.2 61
4×(G)0.75 24/0.20 0.6 6.9 755G0.75 24/0.20 0.6 7.7 946G0.75 24/0.20 0.6 8.3 1077G0.75 24/0.20 0.6 9.1 1278G0.75 24/0.20 0.6 10.2 14410G0.75 24/0.20 0.6 11.1 18614G0.75 24/0.20 0.6 11.7 20316G0.75 24/0.20 0.6 12.5 233
1×1 32/0.20 0.6 3.9 252×1 32/0.20 0.6 6.3 503G1 32/0.20 0.6 6.8 674G1 32/0.20 0.6 7.4 875G1 32/0.20 0.6 8.4 1076G1 32/0.20 0.6 8.9 1247G1 32/0.20 0.6 10.2 1528G1 32/0.20 0.6 11.0 177
10G1 32/0.20 0.6 12.1 22214G1 32/0.20 0.6 12.7 25216G1 32/0.20 0.6 13.6 29019G1 32/0.20 0.6 15.1 33821G1 32/0.20 0.6 16.0 38024G1 32/0.20 0.6 17.1 437
www.addison-cables.com
www.caledonian-cables.co.uk
56
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
25G1 32/0.20 0.6 17.1 46827G1 32/0.20 0.6 17.1 49730G1 32/0.20 0.6 17.7 51433G1 32/0.20 0.6 18.9 58237G1 32/0.20 0.6 20.3 7141×1.5 30/0.25 0.6 4.3 322×1.5 30/0.25 0.6 7.8 893G1.5 30/0.25 0.6 9.1 106
4×(G)1.5 30/0.25 0.6 9.1 1235G1.5 30/0.25 0.6 10.1 1567G1.5 30/0.25 0.6 12.1 22410G1.5 30/0.25 0.6 15.0 31412G1.5 30/0.25 0.6 15.0 34614G1.5 30/0.25 0.6 15.4 36616G1.5 30/0.25 0.6 16.8 41519G1.5 30/0.25 0.6 18.3 48621G1.5 30/0.25 0.6 19.7 56224G1.5 30/0.25 0.6 21.1 64425G1.5 30/0.25 0.6 21.7 69327G1.5 30/0.25 0.6 21.7 73130G1.5 30/0.25 0.6 21.8 76033G1.5 30/0.25 0.6 22.6 83137G1.5 30/0.25 0.6 24.8 10321×2.5 48/0.25 0.7 5.0 452×2.5 48/0.25 0.7 9.1 1023G2.5 48/0.25 0.7 9.9 1454G2.5 48/0.25 0.7 10.9 1895G2.5 48/0.25 0.7 12.2 2356G2.5 48/0.25 0.7 13.2 2887G2.5 48/0.25 0.7 14.6 3448G2.5 48/0.25 0.7 15.7 37910G2.5 48/0.25 0.7 17.7 48212G2.5 48/0.25 0.7 18.7 48314G2.5 48/0.25 0.7 19.0 57216G2.5 48/0.25 0.7 20.1 65119G2.5 48/0.25 0.7 20.7 76521G2.5 48/0.25 0.7 23.7 85724G2.5 48/0.25 0.7 25.8 98425G2.5 48/0.25 0.7 25.8 112127G2.5 48/0.25 0.7 25.8 106930G2.5 48/0.25 0.7 26.7 117533G2.5 48/0.25 0.7 28.0 130137G2.5 48/0.25 0.7 30.6 1599
1×4 56/0.30 0.8 5.6 62
Caledonian Railway Cables
57
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×4 56/0.30 0.8 10.2 1613G4 56/0.30 0.8 10.9 2174G4 56/0.30 0.8 12.8 2685G4 56/0.30 0.8 14.2 3346G4 56/0.30 0.8 14.9 3987G4 56/0.30 0.8 16.4 4588G4 56/0.30 0.8 17.6 523
10G4 56/0.30 0.8 20.1 67412G4 56/0.30 0.8 20.1 68814G4 56/0.30 0.8 21.5 8051×6 81/0.30 0.9 6.1 832×6 81/0.30 0.9 11.6 2133G6 81/0.30 0.9 12.4 2794G6 81/0.30 0.9 13.8 3415G6 81/0.30 0.9 15.8 4946G6 81/0.30 0.9 16.7 5197G6 81/0.30 0.9 18.3 6161×10 78/0.40 1.0 7.7 1362×10 78/0.40 1.0 14.7 3513G10 78/0.40 1.0 15.7 4574G10 78/0.40 1.0 17.5 5905G10 78/0.40 1.0 19.6 7466G10 78/0.40 1.0 21.7 8757G10 78/0.40 1.0 23.7 10241×16 119/0.40 1.1 9.1 2042×16 119/0.40 1.1 17.7 5303G16 119/0.40 1.1 19.3 7074G16 119/0.40 1.1 21.5 9195G16 119/0.40 1.1 23.9 11486G16 119/0.40 1.1 26.2 13697G16 119/0.40 1.1 28.9 15691×25 182/0.40 1.3 10.9 3082×25 182/0.40 1.3 21.3 7923G25 182/0.40 1.3 22.7 9774G25 182/0.40 1.3 25.4 12995G25 182/0.40 1.3 28.1 16306G25 182/0.40 1.3 31.1 19647G25 182/0.40 1.3 34.5 23511×35 266/0.40 1.3 12.1 4142×35 266/0.40 1.3 23.7 10503G35 266/0.40 1.3 25.5 13254G35 266/0.40 1.3 28.4 17475G35 266/0.40 1.3 31.3 21731×50 378/0.40 1.6 14.9 589
www.addison-cables.com
www.caledonian-cables.co.uk
58
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×50 378/0.40 1.6 29.3 14713G50 378/0.40 1.6 31.5 31334G50 378/0.40 1.6 35.3 25145G50 378/0.40 1.6 39.1 31331×70 348/0.50 1.6 17.1 8002×70 348/0.50 1.6 33.7 19823G70 348/0.50 1.6 36.4 25854G70 348/0.50 1.6 40.3 33905G70 348/0.50 1.6 44.5 42331×95 444/0.50 1.8 19.2 10542×95 444/0.50 1.8 37.5 25653G95 444/0.50 1.8 40.0 33264G95 444/0.50 1.8 45.3 44515G95 444/0.50 1.8 50.7 5602
Highly Flexible UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
Weather Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
Caledonian Railway Cables
59
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
FRA 145/S EMC Screened Multicore
º Applications
Multicore cable with improved fire performance and very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.
º Standard
• IEC 60754-1, EN 50267-2-1 (halogen free)• IEC 60754-2, EN 50267-2-2 (no corrosive gases)• NES 02-713, NFC 20-454 (no toxic gases)• IEC 61034, EN 50268-2 (low smoke density)• IEC60332-1,EN50265-2-1(flameretardant)• IEC 60332-3, EN 50266-2, NF C 32-070
(non-flamepropagating)• DIN51900(lowfireload)
º Construction
• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation: Electronbeamcrosslinkablepolyolefinecopolymer.• Screen: Copper wire screen.• Sheath:Electronbeamcrosslinkablepolyolefinecopolymer.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable Polyolefine Copolymer Sheath
Copper Wire Screen
Electron Beam Crosslinkable Polyolefine Copolymer Insulation
www.addison-cables.com
www.caledonian-cables.co.uk
60
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+145℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
1×0.5 19/0.18 0.5 3.7 232×0.5 19/0.18 0.5 5.6 453×0.5 19/0.18 0.5 6.1 594×0.5 19/0.18 0.5 6.7 725×0.5 19/0.18 0.5 7.3 866×0.5 19/0.18 0.5 7.9 1027×0.5 19/0.18 0.5 8.4 1188×0.5 19/0.18 0.5 9.0 13310×0.5 19/0.18 0.5 10.0 15712×0.5 19/0.18 0.5 10.0 1641×0.75 24/0.20 0.6 4.0 282×0.75 24/0.20 0.6 6.7 663×0.75 24/0.20 0.6 7.1 784×0.75 24/0.20 0.6 7.7 945×0.75 24/0.20 0.6 8.5 1136×0.75 24/0.20 0.6 8.9 1327×0.75 24/0.20 0.6 9.9 1588×0.75 24/0.20 0.6 10.6 18110×0.75 24/0.20 0.6 11.5 20912×0.75 24/0.20 0.6 11.5 21914×0.75 24/0.20 0.6 12.2 25116×0.75 24/0.20 0.6 12.9 27919×0.75 24/0.20 0.6 14.5 34721×0.75 24/0.20 0.6 15.3 385
1×1 32/0.20 0.6 4.2 332×1 32/0.20 0.6 7.2 793×1 32/0.20 0.6 7.7 894×1 32/0.20 0.6 8.3 1135×1 32/0.20 0.6 9.0 1346×1 32/0.20 0.6 9.5 1567G1 32/0.20 0.6 10.9 1878×1 32/0.20 0.6 11.4 218
10×1 32/0.20 0.6 12.5 25312×1 32/0.20 0.6 12.5 2661×1.5 30/0.25 0.6 4.8 43
Caledonian Railway Cables
61
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×1.5 30/0.25 0.6 8.4 1053×(G)1.5 30/0.25 0.6 8.9 1194×(G)1.5 30/0.25 0.6 9.9 163
5×1.5 30/0.25 0.6 10.7 1836×1.5 30/0.25 0.6 11.5 219
7×(G)1.5 30/0.25 0.6 12.7 2738×1.5 30/0.25 0.6 13.7 30510×1.5 30/0.25 0.6 15.0 30912×1.5 30/0.25 0.6 15.0 37114×1.5 30/0.25 0.6 16.0 45516×1.5 30/0.25 0.6 17.0 50219×1.5 30/0.25 0.6 19.3 62721×1.5 30/0.25 0.6 20.3 69825×1.5 30/0.25 0.6 21.7 7371×2.5 50/0.25 0.7 5.6 612×2.5 50/0.25 0.7 9.9 157
3×(G)2.5 50/0.25 0.7 10.5 1984×2.5 50/0.25 0.7 11.5 236
5×(G)2.5 50/0.25 0.7 12.6 2876×2.5 50/0.25 0.7 13.8 3217G2.5 50/0.25 0.7 15.5 4308×2.5 50/0.25 0.7 16.5 46110×2.5 50/0.25 0.7 18.3 53412×2.5 50/0.25 0.7 18.3 56914×2.5 50/0.25 0.7 19.6 66416×2.5 50/0.25 0.7 20.7 75319×2.5 50/0.25 0.7 23.5 93421×2.5 50/0.25 0.7 24.4 1022
1×4 56/0.30 0.8 6.3 842×4 56/0.30 0.8 10.9 1743×4 56/0.30 0.8 11.5 2264×4 56/0.30 0.8 13.2 3175G4 56/0.30 0.8 14.5 3766×4 56/0.30 0.8 15.6 4367×4 56/0.30 0.8 17.0 5318×4 56/0.30 0.8 18.3 61010×4 56/0.30 0.8 20.7 73612×4 56/0.30 0.8 20.7 79114×4 56/0.30 0.8 22.1 9101×6 81/0.30 0.9 6.9 1092×6 81/0.30 0.9 12.1 2503×6 81/0.30 0.9 12.8 3164×6 81/0.30 0.9 14.3 404
www.addison-cables.com
www.caledonian-cables.co.uk
62
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
5×6 81/0.30 0.9 16.0 5186×6 81/0.30 0.9 17.4 5957×6 81/0.30 0.9 19.3 7161×10 78/0.40 1.0 8.4 1682×10 78/0.40 1.0 15.1 3903G10 78/0.40 1.0 16.4 5294G10 78/0.40 1.0 18.1 6695G10 78/0.40 1.0 20.2 8406G10 78/0.40 1.0 22.3 9737G10 78/0.40 1.0 24.3 1132
Highly Flexible UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
Weather Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
Caledonian Railway Cables
63
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
FRA 155 Single Core
º Applications
Single core cable with very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc.
º Standard
• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)
º Construction
• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Colour Code: Various colours on request.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 85.9 57.2 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)
Nominal Conductor Cross Section mm² 25 35 50 70 95 120 150 185 240Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.164 0.132 0.108 0.0817Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable
Polyolefine Copolymer Insulation
www.addison-cables.com
www.caledonian-cables.co.uk
64
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
1×0.25 19/0.13 0.5 1.5 41×0.34 19/0.16 0.5 1.6 51×0.50 19/0.18 0.5 1.7 71×0.75 24/0.20 0.6 2.2 101×1.0 32/0.20 0.6 2.6 131×1.5 30/0.25 0.6 2.7 201×2.5 48/0.25 0.7 3.4 311×4.0 56/0.30 0.8 4.1 461×6.0 81/0.30 0.9 5.2 65
1×10.0 78/0.40 1.0 6.4 1101×16.0 119/0.40 1.1 7.6 1651×25.0 182/0.40 1.3 9.2 2501×35.0 266/0.40 1.3 10.6 3451×50.0 378/0.40 1.6 12.3 5501×70.0 348/0.50 1.6 14.6 7801×95.0 444/0.50 1.8 16.3 1010
1×120.0 551/0.50 1.8 18.4 12801×150.0 722/0.50 1.9 20.8 14201×185.0 874/0.50 2.0 22.5 17101×240.0 1147/0.50 2.2 25.7 2250
Highly Flexible UV ResistantNF C32-070-2.2(C1)
IEC 60332-3/EN50266
Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Caledonian Railway Cables
65
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
FRA 155S Oil Resistant Single Core
º Applications
Single core cable with very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc.
º Standard
• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)
º Construction
• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Colour Code: Various colours on request.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.50 0.75 1.0 1.5 2.5 4.0 6.0Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable
Polyolefine Copolymer Insulation
www.addison-cables.com
www.caledonian-cables.co.uk
66
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
1×0.50 19/0.18 0.4 1.7 71×0.75 24/0.20 0.5 2.2 111×1.0 32/0.20 0.6 2.6 151×1.5 30/0.25 0.6 2.7 191×2.5 48/0.25 0.7 3.5 301×4.0 56/0.30 0.8 4.2 451×6.0 81/0.30 0.9 5.2 66
Oil Resistant Highly Flexible UV ResistantNF C32-070-2.2(C1)
IEC 60332-3/EN50266
Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Caledonian Railway Cables
67
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
FRA 155/S Multicore
º Applications
Multicore cable very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.
º Standard
• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)
º Construction
• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Sheath:Electronbeamcrosslinkablepolyolefinecopolymer.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.50 0.75 1.0 1.5 2.5Maximum Conductor Resistance Ω/km 85.9 40.1 26.7 20.0 13.7 8.21Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable Polyolefine Copolymer Sheath
Electron Beam Crosslinkable Polyolefine Copolymer Insulation
www.addison-cables.com
www.caledonian-cables.co.uk
68
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
4×0.25 19/0.13 0.5 5.4 333×0.34 19/0.15 0.5 5.1 282×0.5 19/0.18 0.5 5.2 303×0.5 19/0.18 0.5 5.6 408×0.5 19/0.18 0.5 8.8 10216×0.5 19/0.18 0.5 10.4 1663×0.75 24/0.20 0.6 6.7 594×0.75 24/0.20 0.6 7.5 80
2×1 32/0.20 0.6 7.0 613×1 32/0.20 0.6 7.6 77
2×1.5 30/0.25 0.6 7.5 663×1.5 30/0.25 0.6 7.9 924×1.5 30/0.25 0.6 8.8 1175×1.5 30/0.25 0.6 10.1 1503×2.5 50/0.25 0.7 9.9 1454×2.5 50/0.25 0.7 11.0 1865×2.5 50/0.25 0.7 12.0 2235×1.5 30/0.25 0.6 10.1 1503×2.5 50/0.25 0.7 9.9 1454×2.5 50/0.25 0.7 11.0 1865×2.5 50/0.25 0.7 12.0 223
Highly Flexible UV ResistantNF C32-070-2.2(C1)
IEC 60332-3/EN50266
Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Caledonian Railway Cables
69
HIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES
FRA 155/S EMC Screened Multicore
º Applications
Multicore cable with very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.
º Standard
• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)
º Construction
• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.
• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Screen: Copper wire screen.• Sheath: Electronbeamcrosslinkablepolyolefinecopolymer.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.50 1.5 2.5Maximum Conductor Resistance Ω/km 85.9 40.1 13.7 8.21Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable Polyolefine Copolymer Sheath
Copper Wire Screen
Electron Beam Crosslinkable Polyolefine Copolymer Insulation
www.addison-cables.com
www.caledonian-cables.co.uk
70
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional Area
No.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×0.25 19/0.12 0.5 5.1 346×0.25 19/0.12 0.5 7.0 67
4×2×0.25 19/0.12 0.5 14.0 2774×0.5 19/0.18 0.5 7.6 7616×0.5 19/0.18 0.5 11.6 2063G1.5 30/0.25 0.6 8.7 11910G1.5 30/0.25 0.6 14.7 33216G1.5 30/0.25 0.6 22.0 7408G2.5 50/0.25 0.7 18.0 4989G2.5 50/0.25 0.7 18.6 518
Highly Flexible UV ResistantNF C32-070-2.2(C1)
IEC 60332-3/EN50266
Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Caledonian Railway Cables
71
ORDERING INFORMATION
ORDERING INFORMATION
Ordering Information For GKW Cables
º Cable Code Designation
3GKW - W/S EMC
GKW - W FE180
FE180: Fire Resistant CableElectron-beam
Cross-linked Insulation
Cold Resistant
EMC:Screen
Blank: Non Screened
Testing Voltage
/S: Multicore
Blank: Single core
Electron-beam
Cross-linked Insulation
RW: Reduced Wall/Thin Wall
DW: Dual Wall
MW: Medium Wall
Cold Resistant
Heat Resistant
RW: Reduced Wall/Thin Wall
DW: Dual Wall
MW: Medium WallHeat Resistant
www.addison-cables.com
www.caledonian-cables.co.uk
72
Ordering Information For High Temperature Cables
º Cable Code Designation
FRA 145/S EMC
EMC: Screen
Blank: Non Screened
/S: Multicore
S: Oil Resistant
Blank: Single Core
145: -55℃ ~+145℃
155: -55℃ ~+155℃
UNITED KINGDOMMarchants Industrial Centre,
Mill Lane, Laughton, Lewes,
East Sussex, BN8 6AJ, UK
Tel: 44-207-4195087
Fax: 44-207-8319489
Email: sales@caledonian-cables.co.uk
Website: www.caledonian-cables.co.uk
HONG KONGUnit B 22/F CMA Building
64-66 Connaught Road Central
Hong Kong
Tel: 852-36527508
Fax: 852-35834834
Email: hk@caledonian-cables.co.uk
hk@caledonian-cables.com
SHANGHAIRoom 3501, CITIC Square, 1168 Nanjing Xi Lu,
Shanghai 200041, P.R. China
Tel: 86-21-51119178
Fax: 86-21-52524616
Email: cn@caledonian-cables.co.uk
shanghai@caledonian-cables.com
top related