handheld pressure calibrator model hpc400
Post on 17-Feb-2022
11 Views
Preview:
TRANSCRIPT
ISO 9001 Manufacturer
p r e s s u r e
Specification SheetSS-HPC400
Pressure rangesHPC400-2C Vacuumto2bar/30psiHPC400-7C Vacuumto7bar/100psiHPC400-20C Vacuumto20bar/290psi
Transmitter loop features Transmitterloopmeasurement,24voltDCloopsupplyandHART®resistor.
Easy pressure switch test Openingandclosingpressuresareautomati-callyrecordedanddeadbandiscalculated.Allispresentedinalargegraphicaldisplay.
Useful set of features TheHPC400offersaselectionofusefulfeatures:voltagemeasurement,highspeedminimum/maximumhold,5userspecifiedsetups,highorlowresolution,anddampedreadoutforfluctuatingpressures. Ready-to-use systems TheHPC400isavailableasacompletesystemorasanindependentinstrument.Thesystemsarereadyforuse,completewithcalibrationpump,hose,fittingsandaconvenienthardcasetostorethecompletesystem.
TheHPC400seriesisatruecalibrator,afieldinstrumentdesignedforeasyandreliablecheckandcalibrationofpressure.UsetheHPC400seriesinprocesscontrolapplicationssuchasverificationorcalibrationofpressuregauges,transducers,transmitters,pressureswitches,andsafetyvalves.
TheHPC400seriesisrecognizedforitshighqualityandcarefullyselect-edtime-savingfeaturesmakingcalibrationtaskseasytoperform.Allrel-evantinformationisshowninthelargemultiinformationdisplayatonce,suchas:15differentpressureunits,transmittermAreading,min/maxrecording,peakreading,andsemiautomaticpressureswitchtestfind-ingtheclosing,openingandhysteresispressure(deadband),and5userspecifiedsetupsforfrequentmeasurement/calibrationjobs.Maintenanceoftheinstrumentiseasy.Recalibrationoftheunitcanbeperformedlocallywithanaccuratepressurereference:Noneedtosendtheunitbacktothemanufacturerforrecalibration.Forallsystems,pumpandcalibratorareseparatesoreplacementofthepumpdoesnotrequirereturnofthecompletesystemforrepair.TheHPCcanbedeliveredasanindividualcalibratororasacompletecalibrationsystemreadyforuseinacarryingcase,includingpump,hose,connectors,battery,testleads,usermanual,andtraceablecalibra-tioncertificate.
Handheld Pressure Calibrator
Model HPC400
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
Handheld Pressure Calibrator • Model HPC400
Clear graphical displayLargebacklightgraphicsdisplaythepressure.Iconsshowcurrentstatusandmode,1,2or3measurementwindows,tosuityourapplicationsanddemands.
Useful set of featuresPerformsemi-automaticpressureswitchtests.switchinHARTresistororothercalibrationtasks,assistedbytheoutstandingfunctionsandfeaturesoftheHPC400.
ON / OFFAutoshut-offtoexpandbatterylifetime(userprogram-mable).
ZeroTokeephighaccuracy,adedicatedzerobuttonisavail-abletoprovideconvenientzerobeforetest.
Intuitive menu systemCombinationof“softkeys”andcursorkeypadensuresaneasyoperation.
Pressure connections1/8”BSPfemale.300seriesstainlesssteel.1/4”NPTmaleand1/4”BSPfemaleadaptersaresuppliedasstandard.
Electrical connectionsHPCcalibratorsarewellequippedandincludeinputsformA,voltage,switchesandtemperaturemeasurements,including24VDCsupplyformAtransmitters.
Units15differentpressureengineeringunits.SerialinterfaceConnectionforJOFRAAPMpressuremoduleandforcomputer.
Model HPC400 • Handheld Pressure Calibrator
Pressure; gauge / compound ranges
bar........................................................vacuumto2,7&20psi.......................................... vacuumto15,30,100&290 Engineering units (built-in)
Userselectable........................................................ 15units(bar,mbar,MPa,kPa,inHg@0°C,mmHg@0°C,kg/cm2,mmH2O@4˚C,mmH2O@20˚C,psi,inH2O@4˚C,inH2O@20˚C,inH2O@60˚F,cmH2O@4˚C,cmH2O@20˚C)
Pressure accuracy ambient temp. (18 to 28°C / 65 to 82°F)
Allpressureranges.......................................... ±0.05%F.S.Vacuum............................................................ ±0.10%F.S.F.S.(fullscale)isthenumericalvalueofthepositivepressurerange.Temperatureeffectoutside18to28°C/65to82°F±0.005%F.S./°C
Display
LCD..................................................... Graphical(withlight)Displayresolution..................................................... 5digitsDisplayupdate...................................... 3timespersecond
Input / output (18 to 28°C / 65 to 82°F)
mArange............................................................ 0to24mAmAaccuracy.....................................±0.015%RDG+2µATransmittersupply.........................................24VDC±10%Voltagemeasurement...................................... 0to30VDCVoltageaccuracy................................ ±0.015%RDG+2µVHART® resistor ........................................................... 250 Ω Peak hold capture ........................................50 milliseconds Switch test input ..................................................5V (<1mA) Temperatureeffectoutside18to28°C/65to82°F±0.001%F.S./°C.
Media compatibility
Nickelplatedbrassand316stainlesssteel
Environmental
Operatingtemperature................ -10to50°C/14to122°FStoragetemperature....................-20to60°C/-4to140°FIngressprotectionrating............................................... IP54
Pressure connection
Allcalibrators............................................ 1/8”BSPfemaleAdaptersto1/4”NPTmaleand1/4”BSPfemaleareincludedasstandard.
Pressure overload
Overloadalarm......... “OL”indisplayatapprox.+20%F.S.
Power supply
Battery................................................ 4x1.5VDCAlkalineBatterytype....................................AA,LR6,MN1500,AM3Batterylifetime...................... Typicallymorethan35hoursLowbatterycalibrator.................................................... Yes
Instrument dimensions (LxWxH)
Calibrator........................... 201x99x50mm/8.3x3.9x2.0inHPC400weight(incl.battery)......................635g/22.4ozCalibrator,shipping.......... 243x180x80mm/9.6x7.1x3.1inCalibratorweight,shipping.........................1.1kg/39.5oz
Miscellaneous
Compliance:EN61326:2006&CISPR11,Edition5.0-2009Class“B”
FUNCTIONAL SPECIFICATIONS
4 Handheld Pressure Calibrator • Model HPC400
Function / Feature HPC400Singlesensorhighaccuracypressurecalibrator Yes
mAmeasurement Yes
Voltagemeasurement Yes
24VDCtransmittersupply Yes
Highspeedpressureswitchtest Yes
Highspeedmin./max.hold Yes
Displaycontrastadjustment Yes
Instrumentsetuplock Yes
Storageof5setups Yes
Setupofautomaticofftimer Yes
Setupofnumberofdisplaywindows/measurementchannels Yes
Selectdisplayhighorlowresolution Yes
Setupofbacklighttimer Yes
HARTresistoron/off Yes
Normalordampeddisplayupdaterate Yes
Model HPC400 • Handheld Pressure Calibrator
HPC400calibratorTraceablecalibrationcertificate(NIST)withpressureandvacuumperformance4x1.5voltbatteriesAdapterto1/4”NPTmalefrom1/8”BSPmaleAdapterto1/4”BSPfemalefrom1/8”BSPmale1/8”sealedgasket/washertypeTestleads:redandblackHandstrapwithclipUsermanual
••
•••••••
STANDARD DELIVERY (HPC Calibrator)
HPC400 PRESSURE RANGESThistableshowstheresolutionsthatcanbeobtainedbytheHPCcalibratorsthroughoutallengineeringunits.
HPC400 Ranges and ResolutionsRange(bar) 2 7 20
Burstpressure(bar) 20 70 133
Proofpressure(bar) 4 14 40
Range(psi) 30 100 300
Burstpressure(psi) 300 1000 2000
Proofpressure(psi) 60 200 600
Staticpressure(psi) n/a n/a n/a
psi 30.000 100.00 300.00
bar 2.0684 6.8947 20.684
mbar 2068.4 6894.8 20684
kPa 206.84 689.48 2068.4
MPa 0.2068 0.6894 2.0684
kg/cm2 2.1092 7.0307 21.092
cmH2O@4°C 2109.3 7030.9 21093
cmH2O@20°C 2113.0 7043.4 21130
mmH2O@4°C 21093 70309 n/a
mmH2O@20°C 21130 70434 n/a
inH2O@4°C 830.42 2768.1 8304.2
inH2O@20°C 831.89 2773.0 8318.9
inH2O@60°F 831.23 2770.8 83123
mmHg@0°C 1551.5 5171.5 15515
inHg@0°C 61.081 203.6 610.81
Proofpressure-maximumallowablepressurewithoutashiftincalibration.Burstpressure-sensordamagedordestroyed,someriskofpersonalinjury.
Handheld Pressure Calibrator • Model HPC400
HPC400, System A • AXX/0 to 2 bar (0 to 30 psi) • AHX/0 to 20 bar (0 to 290 psi)ThissystemincludestheHPCcalibra-tortogetherwithonepneumatichandpump:T-960andT-970,dependingonthechosenpressurerange.SystemAisaneasy-to-usesinglehandoperatedcalibrationsystem.Noneedforaflatsurfacetooperatethesystem-justholditinyourhand.
Thesystemcomesinacarryingcasewithcut-outsforfit-tings,hose,andthecompleteassembledcalibrationunit-notimeisrequiredtoassembletheunit.Thecalibratorcanatanytimebeusedseparatelyforotherpressuretestjobs.
Aspecialquickconnectorbetweenthepumpandthecalibratormakesitpossibletoseparatethesysteminsec-ondsandswivelthecalibratorforeasyviewing.
TheHPCcalibratorsusedinSystemAaredeliveredcali-bratedinbothpressureandvacuum.T-960 and T-970 pumps for system AModelT-960pneumaticpressurepumpfeaturesanextendedrangevolumeadjusterforprecisecontrolofthepumppressureandacomfortablepistolgriphandle.
ModelT-970pneumaticpressurepumpissimilartotheT-960,butgeneratespressuresupto20bar(290psi).Pressurerange,T-960.....................0to2bar/0to30psiPressurerange,T-970..................0to20bar/0to290psiType..................................................................... PneumaticTestmedium.....................................................................AirOperation.................................................................. Scissor“O”-rings..................................................................Buna-NWettedparts..........Aluminum,brass,stainlesssteel,nylon,NylatronGSConnectiontotestobject..................Hose0.6m/24inwith1/4”BSPandNPTfemaleterminationsSize................................ 21.6x12.1x6.2cm/8.5x4.8x2.4inWeight............................................................1.4kg/3.0lbIncluded with System A delivery•HPCstandarddelivery(seepage5)•HandpumpT-960orT-970witha0.6m/24inhosewith1/4”BSPandNPTfemaleterminations•3/8”BSPfemaleadapterwith1/4”BSPandNPTfemaleterminations•QuickconnectorbetweenpumpandHPCcalibrator•1rollofTeflontape•ProtectivecarryingcaseAccessories•PressurehoseforT-960/970,0.5meter•PressurehoseforT-960/970,1.0meter•PressurehoseforT-960/970,2.0meter•PressurehoseforT-960/970,5.0meter•SetofBSPfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x3/8”,1x1/2”•SetofNPTfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x1/4”,1x3/8”1x1/2”•ConnectionsforAPMH/Spressuremodules•Fitting1/8”NPTmaleto1/4”NPTmaleforAPM-Hpressuremodule•Fitting1/4”NPTmaleto1/4”NPTmaleforAPM-Spressuremodule
HPC500, System B • BXX/Vacuum to 2 bar (30 psi) • BHX/Vacuum to 20 bar (290 psi)Thissystemincludesthedualfunc-tionpneumatichandpump.Withthispumpyoucancalibratebothvacuumandpressureapplications.Ittakesjustafewsecondstoswitchbetweenvacuumandpressure,justpushonebut-ton(valve)onthehandpump.
TheSystemBcomesinacarryingcasewithcut-outsforfittings,hoseandthecompleteassembledcalibrationunit-notimerequiredtoassembletheunitbeforeuse.
Thecalibratorandthepumparefittedwithaspecialquickconnectorthatmakesitpossibletoseparatethesysteminsecondswithoutanytool.Thisquickconnectoralsomakesitpossibletousetheassembledsystemwiththecalibratortwistedtoanyangle.
T-965 and T-975 hand pumps for system BModelT-965andT-975pneumaticpressurepumpsfea-turebothvacuumandpressuregeneration.Quickswitch(valve)makesiteasytoswitchfromvacuumtopressuremeasurement.Abuilt-inreleasevalve,avolumeadjusterforfineadjustmentandadualpressureoutputenableasafeandsimpleoperation.Theunitoffersbothmetricandimperialthreadsonthereferenceconnectionandthehose.Pressurerange,T-965................... vacuumto2bar(30psi)Pressurerange,T-975............... vacuumto20bar(290psi)Type..................................................................... PneumaticTestmedium.....................................................................AirOperation.................................................................. Scissor“O”-rings..................................................................Buna-NWettedparts..........Aluminum,brass,stainlesssteel,nylon,NylatronGSConnectiontotestobject..................Hose0.6m/24inwith1/4”BSPandNPTfemaleterminationsSize................................ 21.6x12.1x6.2cm/8.5x4.8x2.4inWeight............................................................1.4kg/3.0lbIncluded with System B delivery•HPCstandarddelivery(seepage5)•HandpumpT-965orT-975witha0.6m/24inhosewith1/4”BSPandNPTfemaleterminations•3/8”BSPfemaleadapterwith1/4”BSPandNPTfemaleterminations•QuickconnectorbetweenpumpandHPCcalibrator•1rollofTeflontape•ProtectivecarryingcaseAccessories•PressurehoseforT-975,0.5meter•PressurehoseforT-975,1.0meter•PressurehoseforT-975,2.0meter•PressurehoseforT-975,5.0meter•SetofBSPfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x3/8”,1x1/2”•SetofNPTfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x1/4”,1x3/8”1x1/2”•ConnectionsforAPMH/Spressuremodules•Fitting1/8”NPTmaleto1/4”NPTmaleforAPM-Hpressuremodule•Fitting1/4”NPTmaleto1/4”NPTmaleforAPM-Spressuremodule
Model HPC400 • Handheld Pressure Calibrator
ORDERING INFORMATIONOrdernumber Description
HPC Type
400 Model
NONE Nocalibrator,pressuresystemonly
Pressurerange
002C Vacuumto2bar/30psigauge/compound
007C Vacuumto7bar/100psigauge/compound
020C Vacuumto20bar/290psigauge/compound
Calibrationcertificate
G NISTtraceablecalibrationcertificate
Accessories(Optional)
B Rechargeablebatterypack
C Softcase
Pressuresystem
IND Calibratoronly
AXX Syst.A,T-960pumprangesupto2bar/30psi
AHX Syst.A,T-970pumprangesupto20bar/290psi
BXX Syst.B,T-965pumprangesupto2bar/30psi
BHX Syst.B,T-975pumprangesupto20bar/290psi
Sampleordernumber
HPC 400 020C G BC BHX HPC400,vacuumto20bar,NISTtraceablecertificate,rechargeablebatterypackage,softcase,systemBT-975pump
inthisdocumentissubjecttochangewithoutnotice.©2009,byAMETEK,Inc.,www.ametek.com.Allrightsreserved.
AMETEK Calibration Instrumentsis one of the world’s leading manufacturers and
developers of calibration instruments for temperature, pressure and process signals as well as for
temperature sensors both from a commercial and a technological point of view.
JOFRA Temperature InstrumentsPortable precision thermometers. Dry-block and
liquid bath calibrators: 5 series, with more than 25 models and temperature ranges from
-90° to 1205°C / -130° to 2200°F. All featuring speed, portability, accuracy and advanced documenting
functions with JOFRACAL calibration software.
JOFRA Pressure InstrumentsConvenient electronic systems ranging from
-25 mbar to 1000 bar (0.4 to 15,000 psi) - multiple choices of pressure ranges, pumps and
accuracies, fully temperature-compensated for problem-free and accurate field use.
JOFRA Signal InstrumentsProcess signal measurement and simulation for easy control loop calibration and measurement
tasks - from handheld field instruments to laboratory reference level bench top instruments.
JOFRA Marine InstrumentsA complete range of calibration equipment for
temperature, pressure and signal, approved for marine use.
FP Temperature SensorsA complete range of temperature sensors
for industrial and marine use.
M&G Pressure TestersPneumatic floating-ball or hydraulic piston dead
weight testers with accuracies to 0.015% of reading.
M&G PumpsPressure generators from small pneumatic
“bicycle” style pumps to hydraulic pumps generating up to 1,000 bar (15,000 psi).
...because calibration is a matter of confidence
Rechargable battery kit - Option BTheHPC400isavailablewithasetof4rechargeableAAbatteriesandacharger.
Useful soft case - Option CTheHPC400canbedeliveredwithasoftcaseasoption.Thehandysoftcaseisdesignedforprotectionduringtransport.Thesoftcasehassepa-ratecompartmentsforHPC400(w/Velcrostrap),testleads,testhoses,temperatureprobe,andJOFRAAPMpressuremodule.Ashoulderstrapensuresconvenienttransportationwhenclimbingladders,etc.andthehandystrapatthebackmakesitpossibletohangtheinstrumentonapipe,ladderetc.Themanualandcalibrationdocumentsfitintoapocketonthefrontofthesoftcase.
Complete calibration systems TheHPC400isavailableasacalibratoronlyoroneof6ready-for-testsystemsthatarecompleteandequippedtomeetyourpressurecalibra-tionneeds.
ACCESSORIES
OptionC
99 Washington Street Melrose, MA 02176 Phone 781-665-1400Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
top related