high angular diffusion imaging and its visualization…

Post on 10-Jan-2016

40 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

DESCRIPTION

High Angular Diffusion Imaging and its Visualization…. Limitations of DTI Why HARDI is better?!? Different HARDI models My ideas and current work. Underlying philosophy in DTI. S i. S 0.  1 r 1.  1 r 1.  2 r 2.  1 r 2. From probability to diffusivity. - PowerPoint PPT Presentation

TRANSCRIPT

High Angular Diffusion Imaging and its Visualization…

• Limitations of DTI

• Why HARDI is better?!?

• Different HARDI models

• My ideas and current work

Underlying philosophy in DTI

S0

Si

From probability to diffusivity

• DTI: D(g) = D P(r) = Gaussian

~2µm

2 –

3 o

rders

of

mag

nit

ud

e

diff

ere

nce

1-2mm

1r1

2r2

1r1

1r2

Application - DTI

DTITool, BMIA group TU/e

• What if…– Measure > 6(20) gradient directions– Give more time to the molecules to do

their job

• What if…– Measure: 200-300 gradient directions– Use high b-values: <2000s/mm2 (w.r.t

gradient strength and effective time)

Different approaches

= HARDI

HARDI

• Many different approaches– DSI , q-ball– High-order tensor models w.r.t. ADC– SH representation– PAS-MRI– Multi-compartment models etc..

• All in common: avoid Gaussian model fitting

Reality check…

• Long (more complicated) acquisition scheme

• Popular for phantom data and simulations

• Tricky mathematical models• Non-intuitive visualization

Reality check…

• Scanning time ~0.5h (and much more!)• Phantoms like it – people don’t like it!• Mathematical models:

PDF = mixture of Gaussians

Reality check…

• Scanning time ~0.5h (and much more!)• Phantoms like it – people don’t like it!• Mathematical models:• m

SH representation of ADC

Reality check…

• Scanning time ~0.5h (and much more!)• Phantoms like it – people don’t like it!• Mathematical models:

HOT representation of ADC

…and of course Visualization issues

[Tuch, PhD Thesis 2002]

[Ozarslan, MRM 2003]

[Liu, MRM 2004 ]

My current work, ideas, struggles…

• Comparing most promising methods (w.r.t. feasibility on vivo data) and improve it– DOT and q-ball

• Answer the mysterious 42 question: “How high should be the “high” b-value?”

• DTI is not dead! Combining with HARDI. Define measure where 2nd order tensor is sufficient!

• Segmentation on HARDI data.

• More intuitive HARDI visualization => doctors don’t like glyphs• Fiber tracking on HARDI

• Combining different modalities– Use of fMRI activation zonesas seeding regions for whitematter tractography

My current work, ideas, struggles…

[Hardenbergh, IEEE Vis 2005]

[INRIA-McGill]

Multi-fieldity in HARDI

• Multiple measurements over same domain

• High-dimensional data• High-order mathematical

models (HOT and SH)• Combining HARDI+fMRI

=>Jorik• Sufficient order w.r.t.

encapsulated information=> Stef

top related