hm1 install
Post on 01-Jan-2017
235 Views
Preview:
TRANSCRIPT
HINGED - TYPE HM1
SHMSHSDHM1##
HOLD DOWN LUGS MUST BE INSTALLED
ACCORDING TO WIND CLASSIFICATION
WIND CLASSIFICATIONN1, N2 = 2x HOLD DOWN LUG (HMHL)
N3 = 2x HOLD DOWN LUG (HMHL)
Handi-MateTM Shed
INSTALLATIONGUIDE
2
x1 x2x4
SSPH
MW
SCN
R1900##
CO
RN
ER W
ALL
SH
EET
WA
LL S
HEE
T
RO
OF
SHEE
T
SSPH
MW
S1900##
SSPH
MRS9
15A
Z
x2
BEFORE YOU START
TOOLS REQUIRED
COMPONENTS
Prior to installation, it is important that you contact your local government authority to determine if building approval is required.
To ensure that the installation and erection of your Stratco Handi-MateTM Shed proceeds smoothly you should confirm that all the components and materials listed on the delivery documentation, and in this installation guide, have been supplied. Carefully read this installation guide to familiarise yourself with all the steps involved, and ensure that you have the correct tools and equipment for the job.
NOTE: Use heavy gloves when handling steel sheeting and flashings and never attempt to install a shed in windy conditions.
3
x1 x1
SPLI
T W
ALL
SH
EET
DO
OR A
SSEM
BLY
SSPH
MSW
1900##
HD
JAH
DC
##
4
LEFT HAND BARGE CAP RIGHT HAND BARGE CAP
RID
GE
CA
P
RID
GE
BEA
M
DO
OR
SH
RO
UD
DO
OR
JA
MB
17
50
WA
LL C
HA
NN
EL
70
0 W
ALL
CH
AN
NEL
HMBCHDRL935## HMBCHDRR935##
HM
RC
435G
A
HM
RB750G
A
HM
DSH
DRBO
820G
A
HM
WC
1750G
A
HM
WC
700G
A
HM
DJH
DC
19
00
##
x2 x2
x2 x1 x1 x4x4x1
HM
DTH
DR
CORNERBRACKET
DOORTONGUE
ALUMINIUM RIVET
10x22WAFER
DOORHANDLE
10x16SCREW
10x16WASHER
SCREWRIVET
HM
CBG
AH
MTH
RIV
4-3
RIV
4-3
##
WTK
1022
TEK
NN
W1016
TEK
1016
M8x47MASONRYANCHORM
AA
847
HOLD DOWN
LUGHM
HL
TEK
1025##
x8
x1
x1
N1/N2 x2
N1/N2 x6
10x25WASHER
SCREW
N3 x2
N3 x6
5
1.86
2.00
0.77
1.80 0.75
SITE AND ASSEMBLY PREPARATION
Important Notes
• It is essential to clear and level the site prior to assembling your Stratco Handi-MateTM Shed.• Before starting to build the shed, please refer to the previous pages of this guide for a list of
recommended shed assembly tools and shed components.• Also note there are different types and colour screws. Ensure that the right type and colour screw is
being used at each location.
• Stability and performance of the shed relies on the door being closed during high wind events.
• Do not traverse the roof of the Handi-MateTM Shed.If this is unavoidable, ensure crawl boards or ladders are used over the roof surface to distributethe load.
Preventing Wind Uplift
All Stratco Handi-MateTM Sheds must be securely bolted to a permanent concrete base with sufficient masonry anchors to prevent wind uplift. It is particularly important that masonry anchors are placed within all four corner brackets of the Handi-MateTM Shed. Further anchors and mounting brackets are also used to fix the Handi-MateTM Shed to the permanent concrete base according to shed size. The mounting brackets are to be evenly spaced along the length of the wall.
Concrete Floor
Option 1 - Before building the shed, pour a base that is larger than the area by at least 200mm in each direction. The base should be poured so the concrete that will be outside the shed floor area slopes away from the shed to help prevent water from entering the shed.
Option 2 - Substantial concrete pads may be used at each anchor location as an alternative to a complete concrete floor. It is recommended pads are minimum Ø250mm x 400mm deep, embedded into a firm natural soil base.
6
DOOR
OPTIONAL
!
DOOR TONGUE
10x22 WAFER SCREW
DOOR HANDLE
DOOR ASSEMBLY
1
CORNER WALL SHEET
DOOR DOOR JAMB
FRONT WALL ASSEMBLY
7
2
!
!!
1750 WALL CHANNEL
1750 WALL CHANNEL
3
10x16 SCREW
x4
8
CORNER WALL SHEETSPLIT WALL SHEET
WALL SHEET
1750 WALL CHANNEL
1750 WALL CHANNEL
!
1
2
BACK WALL ASSEMBLY
9
3
4
10x16 SCREW
x41
2
1
1
2
2
POSITION THE WALL SHEETSSO THE SCREWS ARE DRIVENINTO THE CENTRE OF THE PEAK.
!
!
10x16 SCREW
10x16 SCREW
POSITION THE WALL SHEETSSO THE SCREWS ARE DRIVENINTO THE CENTRE OF THE PEAKFOR ALL SCREWS.
RIVETRIVET
10
700 WALL CHANNEL
700 WALL CHANNEL
CORNER WALL SHEET
!
1
SIDE WALL ASSEMBLY
11
!
10x16 SCREW
POSITION THE WALL SHEET SOTHE SCREWS ARE DRIVEN INTO THECENTRE OF THE PEAK.
1
2
1
3 2
1
32
2
12
!
13
REPEAT PROCESS FOR THIRD WALL
CORNERBRACKET
10x16 SCREW
1
2
!
MAKE SURE PRE-PUNCHEDHOLES IN THE CORNER BRACKETAND WALL PANELS ARE ALIGNED.
1
2
SHED ASSEMBLY
14
!!
1
2
3
15
10x16 SCREW
4
5
!
MASONRY ANCHORFIX TO CONCRETE
ONCE SQUARE
CHECK DIAGONALS
FOR SQUARE
16
DOOR SHROUD
DOORSHROUD
10x16 SCREW
USE THE DOOR SHROUD AS SPACER TEMPLATEBETWEEN BOTH DOOR JAMBS.FIX AT BASE.
10x16 SCREW
10x16 SCREW
RIVET
RIVET
RIVET
3
3
1
1
2
2
3
3
6
7
17
RIDGE BEAM
835mm
10x16SCREW
FIXING LOCATIONS FOR ALL ROOF SHEETS
ALL FIXINGS10x16 WASHER SCREWS
3
3.1
4.1
3.2
4.2
3.3
4.3
4
1
TURN UP VALLEYS ON SHEET TO ENCOURAGE WATER TO FLOW
TOWARDS WALLS
2
9
8
18
75mm IN FROM BACK EDGE OF THE RIDGE CAP THEN CONTINUE WITH 300mm SPACING.
1
2
10x16WASHERSCREW
RIDGE CAP
RIDGE CAP
RIDGE BEAM
RIDGE CAP
10
19
210mmMIN
MIN 20mmMAX 50mm
RIGHT BARGE CAP
RIGHT BARGE CAP
LEFT BARGE CAP
MIN 20mmMAX 50mm
LEFT BARGE CAP
10x25WASHERSCREW
10x25WASHERSCREW
12
11
BROCHSDHM1
SECURE THE SHED
HANDY HINT
MAINTENANCE
The installer is responsible for ensuring the slab or concrete squares are sufficient to support the shed and sustain wind loading. Do not directly anchor your shed to pavers.
Your Stratco Handi-MateTM Shed will maintain its good looks for even longer with a simple wash and wipe down. Cleaning should be performed as often as is required to remove any dirt, salt and pollutants.
Stratco Handi-MateTM Sheds are produced from the highest quality materials and will provide many years of service. Refer to the ‘Selection Use and Maintenance’ brochure for more information on how to get the best out of your product.
www.stratco.com.au
CONTACT
1300 165 165
© Copyright April 2016 14/04/16
All brands and logos/images accompanied by ® or ™ are
trade marks of Stratco (Australia) Pty Limited.
MAX. DIST.
(NOT ACTUAL SHED)
MAX. DIST.
MAX. DISTANCEMAX. DISTANCEMAX. DIST.
MA
X.
DIS
T.
MA
X.
DIS
TA
NC
EMA
X. D
ISTA
NC
EM
AX. D
IST.
FIX TO CONCRETEWITH MASONRY
ANCHORS
TEK1016
1
2
!MAXIMUM DISTANCE BETWEEN
HOLD DOWN LUGS (CENTRE TO CENTRE)IS DETERMINED BY WIND CLASSIFICATION
WIND CLASSIFICATIONN1, N2 = 1400mm MAXIMUM (CENTRE TO CENTRE) N3 = 900mm MAXIMUM (CENTRE TO CENTRE)
SHEETS OFF GROUND DURING WALL ASSEMBLY
HOLD DOWN LUG
ALL HOLD DOWN LUG SCREWS SHALL BE SECURED THROUGH BOTH THE WALL CHANNELS AND WALL SHEETS.