humidity control concept enercov systems by yf yap enercov co
Post on 22-Dec-2015
286 Views
Preview:
TRANSCRIPT
Hu
mid
ity
Con
trol C
on
cep
t
ENERCOV SYSTEMS
By
YF Yap
Enercov Co.
Hu
mid
ity
Con
trol C
on
cep
t1. ENERCOV (SUZHOU) Co Ltd
Block B, B6-7, Suhong Ind Square,#81 Suhong West Road,Suzhou Industrial Park,JiangSu, China 215021
2. ENERCOV (THAILAND) Co Ltd52/1 Moo 13 Krungthep-Kreeta Road,Sapansung, Bangkok 10250Thailand
3. ENERCOV (SINGAPORE) Co Ltd80 Genting Lane #06-02, Genting Block,Ruby Industrial Complex,Singapore 349565
Hu
mid
ity
Con
trol C
on
cep
t
We are
TEMPERATURE ,HUMIDITY & CONTROLS
SPECIALISTS
Hu
mid
ity
Con
trol C
on
cep
t
Presentation Details
1. Company Policies2. Desiccant Application3. Enercov Application4. Enercov’s Control System5. Enercov’s Components6. Proposals to NTU7. Job References8. Conclusion9. Questions & Answers
Company Policy
Hu
mid
ity
Con
trol C
on
cep
t
1. Assist our customers to reach the bestsolution for your needs.
2. Design your unit.3. Use Good Quality Components.4. Assemble and Start Up.5. Provide Good After Sales Service.6. Customer Satisfaction.
Hu
mid
ity
Con
trol C
on
cep
t Desiccant Application
Hu
mid
ity
Con
trol C
on
cep
t
Desiccant Wheel
HumidifiedExhaust Air Outside Air
HumidifiedRoom Air
DehumidifiedAir into
CleanRoom
--------------------------------------------------
Hu
mid
ity
Con
trol C
on
cep
tDesiccant
Advantages1. It can be used for very low
Room Dew Point Temp < 4 deg C2. It can be used to achieve RH < 10%
Disadvantages1. High Power Consumption due to Heating
Element.2. Steps control and not analog.3. High Maintenance Cost. Need to change
filter and Desiccant.4. Loose Desiccant can contaminate the supply air .5. Need big floor space.
ANNUAL SAVINGS H
um
idit
y
Con
trol C
on
cep
t
Hu
mid
ity
Con
trol C
on
cep
t ENERCOVmeans
ENERGY RECOVERY
Hu
mid
ity
Con
trol C
on
cep
t
DX Coil
EvaporatorCoil
Hu
mid
ity
Con
trol C
on
cep
t
ENERCOV SYSTEM Evaporator
CoilCondenser
Coil
Semi HermeticCompressor
Chilled WaterCoil
Hu
mid
ity
Con
trol C
on
cep
t
Refrigeration Cycle Diagram
Hu
mid
ity
Con
trol C
on
cep
t
Psychometric Explaination
Outdoor Condition
RoomCondition
Coolin
g
Heating
Hu
mid
ity
Con
trol C
on
cep
t
DX Coils
Advantages1. Uses Energy Recovery. Very little energy wasted.2. VSD control. Analog Control.3. Most cost effective to control RH above 30%.4. Low Maintenance Cost. Wash the coil with water.5. No contamination to supply air due to no direct
contact media. 6. DX coils is build into the AHU. Need less space.
Disadvantages1. Limitations to control RH below 30% RH due to
minimum suction gas temp of 3 deg C.
Hu
mid
ity
Con
trol C
on
cep
t
ITS SOUND SIMPLE
BUT ALL THIS THINGS
IS NOT COMPLETE WITHOUT
TOTAL CONTROL
Hu
mid
ity
Con
trol C
on
cep
tConventional Air Conditioner
& Desiccant Control
1. Room RH Sensor Activate when RH above 55%.2. Signal send to DDC.3. Activate to ON the Desiccant Unit. 3 stages heater
in Desiccant Unit fully ON.4. RH of Room Drops to 50%. Then , 1 stage heater OFF.5. Once RH drops below 45% , 3 stages heater OFF.6. Once RH above 55% , 3 stages heater ON again.7. This system uses STEP CONTROL and NOT
ANALOG CONTROL.8. MOST IMPORTANTLY Control DEHUMI-
DIFICATION & COOLING SEPARATELY.
Bio
safe
ty L
ab
ora
tory
Con
cep
tConventional Air Conditioner
Hu
mid
ity
Con
trol C
on
cep
t
RESULTS WITH ENERCOV SYSTEMH
umid
ity
Con
trol
Con
cept
Hu
mid
ity
Con
trol C
on
cep
t
RESULTS WITH ENERCOV SYSTEMH
um
idit
y
Con
trol C
on
cep
t
Hu
mid
ity
Con
trol C
on
cep
t
Before we can start to CONTROL
We must know
What are the
CONTROL MODE
HeatingHeatingCoolingCooling
DehumidificationDehumidification
HumidificationHumidification
Hu
mid
ity
Con
trol C
on
cep
t
Process of the Air
Hu
mid
ity
Con
trol C
on
cep
t
ENERCOV SYSTEM
CONTROL Dehumidification, Cooling,Heating & Humidification to keep
Temperature and Relative Humidityof the ROOM as
CONSTANT as POSSIBLE.
ENERCOV Humidity Total Control Concept
DX COILSHot Gas Reheat,Hot Gas Bypass,
VSD &DDC Controls System
Hu
mid
ity
Con
trol C
on
cep
t
High Quality Components UsedH
um
idit
y
Con
trol C
on
cep
t 1. Air Handling Unit – Carrier, Robatherm, etc2. Humidity Control Unit3. Carlyle Compressor4. CAREL Controller, Panel & Sensors5. CAREL Steam Humidifier6. Others
Hu
mid
ity
Con
trol C
on
cep
t
CARRIER AHU
Hu
mid
ity
Con
trol C
on
cep
t
HUMIDITY CONTROL UNIT
CAREL CONTROLLER, PANEL & SENSORS
DDC PROGRAMMABLE4 x 20 LCD Display
Temperature &Humidity Sensor
Pco1 Controller
Hu
mid
ity
Con
trol C
on
cep
t
Hu
mid
ity
Con
trol C
on
cep
t
CAREL STEAM HUMIDIFIER
We would like to Proposed to the
TOP MANAGEMENT ofNANYANG TECHNOLOGICAL
UNIVERSITY ( NTU )
Hu
mid
ity
Con
trol C
on
cep
t
PROPOSE ENERCOV SYSTEM
AHUEnercov Unit
AND
CONTROLLER, PANEL & SENSORS
DDC PROGRAMMABLE4 x 20 LCD Display
Temperature &Humidity Sensor
Pco1 Controller
Hu
mid
ity
Con
trol C
on
cep
tENERCOV’S CONTROL
Hu
mid
ity
Con
trol C
on
cep
tSCHEMATIC DIAGRAM
Hu
mid
ity
Con
trol C
on
cep
t
ENERCOV CONTROL ITEMS
1. Two sets of Sensors Temperature & HumidityOne at Supply Air and One in the Room.
2. Solenoid Valve to Control The Reheat Coil.3. Control Valve to Control Chilled Water Coil.4. Solenoid Valve to Control the HotGassBypass.5. Temp Sensor for Air Off Chilled Water Coil.6. Temp Sensor for Air Off DX Cooling Coil.7. Others
Control Points ScheduleH
um
idit
y
Con
trol C
on
cep
t
Psychometric ProcessH
um
idit
y
Con
trol C
on
cep
t
ENERCOV
DX Cooling Coil
( 20kW Only )
ENERCOVDX Heating Coil
MU
NT
ER
’S Dehum
id
( 98 kW)
Hu
mid
ity
Con
trol C
on
cep
t
DX Cooling Coil
Total Cooling 31.58 kWSensible Heat Rat 0.51Sensible Heat 16.1 kWLatent Heat 15.5 kW
Chilled Water Coil
48.4 kW0.94
45.5kW2.9kW
ENERCOV FLEXIBILITY
Range for Sensible Heat 9.1 kW to 61.6 kWRange for Latent Heat 0.58 kW to 18.4 kW
Hu
mid
ity
Con
trol C
on
cep
t
ENERCOV SYSTEM
CONTROL Dehumidification, Cooling,& Heating to keep
Temperature and Relative Humidityof the ROOM as
CONSTANT as POSSIBLE.
RESULTS WITH ENERCOV SYSTEMH
umid
ity
Con
trol
Con
cept
Hu
mid
ity
Con
trol C
on
cep
t
Hu
mid
ity
Con
trol C
on
cep
t
TOTAL CONTROL
TEMPERATURE 22 +/-1 deg Celcius
and
RELATIVE HUMIDITY 40%-50% RH
JOB REFERENCES
Hu
mid
ity
Con
trol C
on
cep
t
JOB REFERENCESH
um
idit
y
Con
trol C
on
cep
t 1. Takeda Lace Co Ltd Bangkok.2. Biological Safety Lab Level 3 in Ministry of
Health Thailand.3. NSM Factory Co Ltd.4. UL & CE Standard Testing Room Bangkok.5. Ministry of Medicine Thailand Vaccine
Production Class 10000.
Hu
mid
ity
Con
trol C
on
cep
t
1. Takeda Lace Co Ltd
• Temperature 24 deg C +/- 1 deg C• Relative Humidity 65% +/- 2% RH• DDC micro processor based control system• Steam Humidifier capacity control• Cooling / Heating / Dehumidification /
Hum are controlled in proportional linearity.
Hu
mid
ity
Con
trol C
on
cep
t
Takeda Lace Co Ltd
Hu
mid
ity
Con
trol C
on
cep
t
2. Biological Lab Safety 3 Ministry of Health Thailand
• Temperature 23 deg C +/- 1 deg C• Relative Humidity 50% +/- 5% RH• Room Pressure Clean Room - 20 Pa• Room Pressure Clean Room + 20 Pa• 100% Outdoor Air Intake• DDC micro processor based control system• Hot gas bypass system
Hu
mid
ity
Con
trol C
on
cep
t
Biological Lab Safety 3 Ministry of Health Thailand
Biological Lab Safety 3 Ministry of Health Thailand
CONTROL POINT DIAGRAMFOR BSL-3 LABORATORY FACILITY
DATE : 15-SEP-2003
?2 ?C
?10 %rh
Hu
mid
ity
Con
trol C
on
cep
t
Hu
mid
ity
Con
trol C
on
cep
t
3. NSM Factory Co Ltd
• Temperature 27 deg C +/- 1 deg C• Relative Humidity < 40% RH• Double series evaporator coils system• Hot gas by pass system• DDC micro processor based control system
Hu
mid
ity
Con
trol C
on
cep
t
4. UL & CE Standard Testing Room ( Air Conditioner Performance Testing Room 12000 - 72000 Btu/Hr )
• Room Temperature Error +/- 1 deg C• Room Humidity Error +/- 5% RH• Steam Humidifier capacity control• Cooling / Heating / Dehumidification / Hum are controlled in proportional linearity.
Hu
mid
ity
Con
trol C
on
cep
t
UL & CE Standard Testing Room
Hu
mid
ity
Con
trol C
on
cep
t
UL & CE Standard Testing Room
Hu
mid
ity
Con
trol C
on
cep
t
5. Vaccine Production Clean Room Class 10000
• Room Temperature < 22 deg C• Room Humidity 50% +/- 10% RH• Room Pressure 10 – 20 Pa• GMP Clean Room Class 10000• Air Change per Hour 30• Cooling / Heating / Dehumidification / Hum are controlled in proportional linearity.
Hu
mid
ity
Con
trol C
on
cep
t
Vaccine Production Clean Room Class 10000
CONCLUSION
Hu
mid
ity
Con
trol C
on
cep
t
TOTAL CONTROL ON THE TEMPERATURE & RELATIVE HUMIDITY
Hum
idit
y C
ontr
ol C
once
ptH
um
idit
y
Con
trol C
on
cep
t
Hu
mid
ity
Con
trol C
on
cep
tSUMMARY OF ENERCOV SYSTEM
1. CONTROL TEMPERATURE & RH by CONTROLLING COOLING, HEATING,DEHUMIDIFICATION SILMULTANEOSLY.
2. USES MICROPROCESSOR CONTROL.3. HAVE MORE THAN 20 POINTS SENSOR &
CAN BE ADJUSTED TO MEET DESIRED TEMPEARATURE & RH OF THE ROOM.
4. USER FRIENDLY.5. ASSURANCE THAT TEMPERATURE
22 C +/- 1 deg C.6. ASSURANCE RELATIVE HUMIDITY
40% - 50% RH.
Hu
mid
ity
Con
trol C
on
cep
tENERCOV is providing a
BRAIN for the Air Conditioning System to
CONTROL the Temperature 22 -/+ 1 deg C and
Relative Humidity 40 - 50% RH& Save at least 70% Energy Compare
To Desiccant Unit
ITS our JOB to PROTECT
THE EARTH for the
FUTURE of OUR CHILDREN
SAVE ENERGY