iad configuration(ss) 31

Post on 02-Jul-2015

122 Views

Category:

Devices & Hardware

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

Lad configuration

TRANSCRIPT

CN D&T Group

IAD Configuration (SS)

V1.1

2

Objects

1. Configuration of SPC Property

2. Configuration of SPC Capacity

3. IAD Gateway Cluster Configuration

4. Configuration of Data Area Capacity

5. Zone to Card Configuration

6. Reboot the SPC Card

7. IAD Node Configuration

8. IAD User Configuration

9. TID Default Attribute Configuration

10. Configuration of the TID Name

These slides will show you the details about IAD configuration on SS. Including the following steps:

3

Configuration of SPC Property

We must select Call & H.248 in processing scope to configure IAD on particular SPC Card

Right Click SS Configure Management Globe Configuration SS Data Configuration Shelf Configuration Right Click SPC Card Property Configuration

4

Configuration of SPC Property

Chennai IAD has Configured in 3rd Shelf 14th SPC Card (LSQ=94)

LSQ= [(Shelf No.-1)*40+Slot No.]

5

Configuration of SPC Capacity

Right Click SS Configure Management Globe Configuration SS Data Configuration Shelf Configuration Right Click SPC Card Property Configuration

The Capacity should be filled in according to the actual situation

For IAD, the following should be configured.

Capacity of the TID text

Subscriber Capacity

Maximum Nodes

6

Configuration of SPC Capacity

7

IAD Gateway Cluster Configuration

Gateway Cluster is the set of gateway nodes with the same properties. The nodes with different equipment types cannot exist in the same gateway cluster. In the SS system, SPC data area and hundred groups are allocated in the unit of gateway cluster. Before addition of IAD equipment, the gateway cluster where this IAD equipment resides should be configured.

Right Click SS Configure Management

8

IAD Gateway Cluster Configuration

9

IAD Gateway Cluster Configuration

Chennai IAD Zone=100

Area Code=44

10

Configuration of Data Area Capacity

The SPC of SS control equipment processes calls & protocols based on the gateway cluster. After a gateway cluster is added, we need to allocate an SPC for it.

Right Click SS Configure Management Globe Configuration SS Data Configuration Shelf Configuration Right Click SPC Card Data Area Capacity Configuration Click “Add”

11

Configuration of Data Area Capacity

12

Configuration of Data Area Capacity

13

Configuration of Data Area Capacity

14

Zone to Card Configuration

We must allocate services, protocols and authentication of users in the zone (gateway cluster) to the SPC board for processing.

15

Configuration of Data Area Capacity

Chennai Zone=100

SPC Card=94

16

Reboot the SPC Card

Right Click SS and Select Command Line Terminal

17

Reboot the SPC Card

Command: 1211:3, 14,”YYYYMMDD”

18

IAD Node Configuration

Double Click on the zone to which a node is added to enter the zone

19

IAD Node Configuration

Chennai Node ID=100

Chennai IAD IP=10.64.2.22

20

IAD Node Configuration

Device Property

21

IAD User Configuration

DNHM Configuration

1. Local Office Code

Click Add and Select Add Local Office Code

22

IAD User Configuration

Chennai Area Code=44

Office Code for IAD=8888

User No. Length=3

23

IAD User Configuration

2. Configuration of the Hundred Group

Click Add and Select Add Hundred Set

Click the Hundred groups to be allocated, and press [<], this hundred group will be moved to the list on the left, which means that this hundred group will be allocated to the Zone.

24

IAD User Configuration

Local Office User Configuration

User Configuration Local Office User Configuration Click “Add”

25

TID Default Attribute Configuration

Here we have to specify the default property template and packet template ID for different terminal types.

Enter in to the Zone and Select Default Attribute Configuration

26

TID Default Attribute Configuration

Click “Add” Subscriber

27

TID Default Attribute Configuration

RTP

28

Configuration of the TID Name

TID Name is the terminal ID in the H.248 protocol, used for identifying the physical termination point (user circuit) and the logic termination point (RTP Port).

29

Configuration of the TID Name

Select “Add” then “Add TID Name”

User Circuit

30

Configuration of the TID Name

RTP Port

univ.zte.com.cn

top related