inf08 030 b - abb group · n° inf08/030 rev. b product c1300 advanced circular chart recorder...
Post on 02-Apr-2018
221 Views
Preview:
TRANSCRIPT
INFORMATION
C1300 Custom Configuration
N° INF08/030 Rev. B Product C1300 Advanced Circular Chart Recorder Manual IM/C1300Issue 6 onwards
1 IntroductionABB can supply custom configurations for the C1300 Advanced Circular Chart Recorder on request.
Enter the required setting or place a check mark () against the relevant parameters in the following tables and return this documentto the Global Sales office at Stonehouse.
2 Common ConfigurationChart Duration
Stop Chart Source
Auto Pen Drop ( the box required)
Yes
No
Pen Lift enable ( the box required)
Yes
No
Configuration Password
Pen Channel Display ( the box required)
Off
Separate
Dual
Separate & Dual
Totalizers Display ( the box required)
Off
Separate
Rate with Total
Total with rate
Dual Total
Dual + Flow rate
Other channels display ( the box required)
Yes
No
Alarm Adjust ( the box required)
Yes
No
Totalizer Reset ( the box required)
Yes
No
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 3 Channels Configuration
2 INF08/030 Rev. B
3 Channels ConfigurationReferring to Section 3.5 of the User Guide (IM/C1300), enter the settings required for each of the channels.
3.1 Channel 1
Trend type
Pen Tag
Pen 1 Input type ( the input type required)
None
Millivolt
Milliamp
High Ohm
Low Ohm
Volts
Thermocouple
RTD
Linearizer Type ( the linearizer type required)
THC Type B
THC Type E
THC Type J
THC Type K
THC Type N
THC Type R
THC Type S
THC Type T
RTD
Square root
3/2
5/2
Channel Units (enter the units required)
Electrical Input Range (enter the values required)
High
Low
Decimal Point ( the number of decimal places required)
0
1
2
3
4
Electrical Input Range (enter the values required)
High
Low
Pen Range (enter the values required)
High
Low
Broken Sensor Protection Drive ( the drive direction required)
Downscale
None
Upscale
Fault Detection Level % (enter the tolerance required)
Pen 1 Filter Time (enter the filter time required)
Pen 1 Event type
Pen Off Tag
Pen In Tag
Pen Out Tag
Pen In Source
Pen Out Source
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 3 Channels Configuration
INF08/030 Rev. B 3
3.2 Channel 2
Trend type
Pen Tag
Pen 2 Input type ( the input type required)
None
Millivolt
Milliamp
High Ohm
Low Ohm
Volts
Thermocouple
RTD
Linearizer Type ( the linearizer type required)
THC Type B
THC Type E
THC Type J
THC Type K
THC Type N
THC Type R
THC Type S
THC Type T
RTD
Square root
3/2
5/2
Channel Units (enter the units required)
Electrical Input Range (enter the values required)
High
Low
Decimal Point ( the number of decimal places required)
0
1
2
3
4
Electrical Input Range (enter the values required)
High
Low
Pen Range (enter the values required)
High
Low
Broken Sensor Protection Drive ( the drive direction required)
Downscale
None
Upscale
Fault Detection Level % (enter the tolerance required)
Pen 2 Filter Time (enter the filter time required)
Pen 2 Event type
Pen Off Tag
Pen In Tag
Pen Out Tag
Pen In Source
Pen Out Source
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 3 Channels Configuration
4 INF08/030 Rev. B
3.3 Channel 3
Trend type
Pen Tag
Pen 3 Input type ( the input type required)
None
Millivolt
Milliamp
High Ohm
Low Ohm
Volts
Thermocouple
RTD
Linearizer Type ( the linearizer type required)
THC Type B
THC Type E
THC Type J
THC Type K
THC Type N
THC Type R
THC Type S
THC Type T
RTD
Square root
3/2
5/2
Channel Units (enter the units required)
Electrical Input Range (enter the values required)
High
Low
Decimal Point ( the number of decimal places required)
0
1
2
3
4
Electrical Input Range (enter the values required)
High
Low
Pen Range (enter the values required)
High
Low
Broken Sensor Protection Drive ( the drive direction required)
Downscale
None
Upscale
Fault Detection Level % (enter the tolerance required)
Pen 3 Filter Time (enter the filter time required)
Pen 1 Event type
Pen Off Tag
Pen In Tag
Pen Out Tag
Pen In Source
Pen Out Source
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 3 Channels Configuration
INF08/030 Rev. B 5
3.4 Channel 4
Trend type
Pen Tag
Pen 4 Input type ( the input type required)
None
Millivolt
Milliamp
High Ohm
Low Ohm
Volts
Thermocouple
RTD
Linearizer Type ( the linearizer type required)
THC Type B
THC Type E
THC Type J
THC Type K
THC Type N
THC Type R
THC Type S
THC Type T
RTD
Square root
3/2
5/2
Channel Units (enter the units required)
Electrical Input Range (enter the values required)
High
Low
Decimal Point ( the number of decimal places required)
0
1
2
3
4
Electrical Input Range (enter the values required)
High
Low
Pen Range (enter the values required)
High
Low
Broken Sensor Protection Drive ( the drive direction required)
Downscale
None
Upscale
Fault Detection Level % (enter the tolerance required)
Pen 4 Filter Time (enter the filter time required)
Pen 4 Event type
Pen Off Tag
Pen In Tag
Pen Out Tag
Pen In Source
Pen Out Source
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 4 Alarm Configuration
6 INF08/030 Rev. B
4 Alarm ConfigurationReferring to Section 3.6 of the User Guide (IM/C1300), enter the settings required for each of the alarms.
4.1 Alarm A1
4.2 Alarm B1
4.3 Alarm C1
4.4 Alarm D1
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 4 Alarm Configuration
INF08/030 Rev. B 7
4.5 Alarm A2
4.6 Alarm B2
4.7 Alarm C2
4.8 Alarm D2
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 4 Alarm Configuration
8 INF08/030 Rev. B
4.9 Alarm A3
4.10 Alarm B3
4.11 Alarm C3
4.12 Alarm D3
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 4 Alarm Configuration
INF08/030 Rev. B 9
4.13 Alarm A4
4.14 Alarm B4
4.15 Alarm C4
4.16 Alarm D4
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
Type ( the alarm type required)
Off
High Process
Low Process
Fast Rate
Slow Rate
Trip Level (enter the trip point value required)
Hysteresis (enter the hysteresis value required)
Time Hysteresis (enter the time hysteresis value required)
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 5 Totalizers Configuration
10 INF08/030 Rev. B
5 Totalizers ConfigurationReferring to Section 3.7 of the User Guide (IM/C1300), enter the settings required for each of the totalizers.
5.1 Totalizer 1
Totalizer Source (enter the source required)
Totalizer Tag (enter the tag required)
Totalizer Count Direction ( the count direction required)
Up
Down
Totalizer Units (enter the units required)
Totalizer Count Rate (enter the value required)
Totalizer Cut Off Value (enter the value required)
Totalizer Preset Value (enter the value required)
Totalizer Predetermined Value (enter the value required)
Totalizer Reset Source (enter the value required)
Totalizer Wrap Enable ( the setting required)
On
Off
Totalizer Reset Days ( the setting required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Mon-Fri
All
1st of Month
Totalizer Reset Time (enter the time required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Totalizer Run Source (enter the source required)
Totalizer Log Enable ( the setting required)
None
Prior to reset
12 hours
24 hours
Totalizer Log Start Time (enter the time required)Note. Applicable only if 'Log Enable Source' required to be '12 hours' or '24 hours'
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 5 Totalizers Configuration
INF08/030 Rev. B 11
5.2 Totalizer 2
Totalizer Source (enter the source required)
Totalizer Tag (enter the tag required)
Totalizer Count Direction ( the count direction required)
Up
Down
Totalizer Units (enter the units required)
Totalizer Count Rate (enter the value required)
Totalizer Cut Off Value (enter the value required)
Totalizer Preset Value (enter the value required)
Totalizer Predetermined Value (enter the value required)
Totalizer Reset Source (enter the value required)
Totalizer Wrap Enable ( the setting required)
On
Off
Totalizer Reset Days ( the setting required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Mon-Fri
All
1st of Month
Totalizer Reset Time (enter the time required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Totalizer Run Source (enter the source required)
Totalizer Log Enable ( the setting required)
None
Prior to reset
12 hours
24 hours
Totalizer Log Start Time (enter the time required)Note. Applicable only if 'Log Enable Source' required to be '12 hours' or '24 hours'
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 5 Totalizers Configuration
12 INF08/030 Rev. B
5.3 Totalizer 3
Totalizer Source (enter the source required)
Totalizer Tag (enter the tag required)
Totalizer Count Direction ( the count direction required)
Up
Down
Totalizer Units (enter the units required)
Totalizer Count Rate (enter the value required)
Totalizer Cut Off Value (enter the value required)
Totalizer Preset Value (enter the value required)
Totalizer Predetermined Value (enter the value required)
Totalizer Reset Source (enter the value required)
Totalizer Wrap Enable ( the setting required)
On
Off
Totalizer Reset Days ( the setting required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Mon-Fri
All
1st of Month
Totalizer Reset Time (enter the time required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Totalizer Run Source (enter the source required)
Totalizer Log Enable ( the setting required)
None
Prior to reset
12 hours
24 hours
Totalizer Log Start Time (enter the time required)Note. Applicable only if 'Log Enable Source' required to be '12 hours' or '24 hours'
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 5 Totalizers Configuration
INF08/030 Rev. B 13
5.4 Totalizer 4
Totalizer Source (enter the source required)
Totalizer Tag (enter the tag required)
Totalizer Count Direction ( the count direction required)
Up
Down
Totalizer Units (enter the units required)
Totalizer Count Rate (enter the value required)
Totalizer Cut Off Value (enter the value required)
Totalizer Preset Value (enter the value required)
Totalizer Predetermined Value (enter the value required)
Totalizer Reset Source (enter the value required)
Totalizer Wrap Enable ( the setting required)
On
Off
Totalizer Reset Days ( the setting required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Mon-Fri
All
1st of Month
Totalizer Reset Time (enter the time required)Note. Applicable only if 'Reset Source' required to be 'Timed'
Totalizer Run Source (enter the source required)
Totalizer Log Enable ( the setting required)
None
Prior to reset
12 hours
24 hours
Totalizer Log Start Time (enter the time required)Note. Applicable only if 'Log Enable Source' required to be '12 hours' or '24 hours'
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 6 Relay Configuration
14 INF08/030 Rev. B
6 Relay ConfigurationReferring to Section 3.8 of the User Guide (IM/C1300), enter the settings required for each of the relays.
Relay Module Type 3 in Position 4 (if fitted)(for each relay, enter the source and the polarity required)
Relay Module Type 3 in Position 5 (if fitted)(for each relay, enter the source and the polarity required)
Relay 1.1 (Input 1) (enter the source and the polarity required)
Source
Polarity Positive Negative
Relay 2.1 (Input 2)(enter the source and the polarity required)
Source
Polarity Positive Negative
Relay 3.1 (Input 3)(enter the source and the polarity required)
Source
Polarity Positive Negative
Relay 4.1 (Input 4)(enter the source and the polarity required)
Source
Polarity Positive Negative
Relay 4.1
Source
Polarity Positive Negative
Relay 4.2
Source
Polarity Positive Negative
Relay 4.3
Source
Polarity Positive Negative
Relay 4.4
Source
Polarity Positive Negative
Relay 5.1
Source
Polarity Positive Negative
Relay 5.2
Source
Polarity Positive Negative
Relay 5.3
Source
Polarity Positive Negative
Relay 5.4
Source
Polarity Positive Negative
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 7 Digital I/O Configuration
INF08/030 Rev. B 15
7 Digital I/O ConfigurationReferring to the Programming Guide (IM/C1900–PGR), enter the settings required for each of the digital outputs.
7.1 Digital Output board position 4 7.2 Digital Output board position 5
Dig OP 4.1
Source
Polarity
Dig OP 4.2
Source
Polarity
Dig OP 4.3
Source
Polarity
Dig OP 4.4
Source
Polarity
Dig OP 4.5
Source
Polarity
Dig OP 4.6
Source
Polarity
Dig OP 4.7
Source
Polarity
Dig OP 4.8
Source
Polarity
Dig OP 5.1
Source
Polarity
Dig OP 5.2
Source
Polarity
Dig OP 5.3
Source
Polarity
Dig OP 5.4
Source
Polarity
Dig OP 5.5
Source
Polarity
Dig OP 5.6
Source
Polarity
Dig OP 5.7
Source
Polarity
Dig OP 5.8
Source
Polarity
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 7 Digital I/O Configuration
16 INF08/030 Rev. B
7.3 Digital Output board position 6 7.4 Digital Inputs I/O Module 1
7.5 Digital Inputs I/O Module 2
7.6 Digital Inputs I/O Module 3
7.7 Digital Inputs I/O Module 4
Dig OP 6.1
Source
Polarity
Dig OP 6.2
Source
Polarity
Dig OP 6.3
Source
Polarity
Dig OP 6.4
Source
Polarity
Dig OP 6.5
Source
Polarity
Dig OP 6.6
Source
Polarity
Dig OP 6.7
Source
Polarity
Dig OP 6.8
Source
Polarity
Dig IP 1.1
Polarity
Dig IP 1.2
Polarity
Dig IP 2.1
Polarity
Dig IP 2.2
Polarity
Dig IP 3.1
Polarity
Dig IP 3.2
Polarity
Dig IP 4.1
Polarity
Dig IP 4.2
Polarity
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 7 Digital I/O Configuration
INF08/030 Rev. B 17
7.8 Digital Input Output Module position 4 7.9 Digital Input Output Module position 5
Dig IP 4.1
Polarity
Dig IP 4.2
Polarity
Dig IP 4.3
Polarity
Dig IP 4.4
Polarity
Dig IP 4.5
Polarity
Dig IP 4.6
Polarity
Dig OP 4.7
Polarity
Dig OP 4.8
Polarity
Dig IP 5.1
Polarity
Dig IP 5.2
Polarity
Dig IP 5.3
Polarity
Dig IP 5.4
Polarity
Dig IP 5.5
Polarity
Dig IP 5.6
Polarity
Dig OP 5.7
Polarity
Dig OP 5.8
Polarity
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 7 Digital I/O Configuration
18 INF08/030 Rev. B
7.10 Digital Input Output Module position 6
Dig IP 6.1
Polarity
Dig IP 6.2
Polarity
Dig IP 6.3
Polarity
Dig IP 6.4
Polarity
Dig IP 6.5
Polarity
Dig IP 6.6
Polarity
Dig OP 6.7
Polarity
Dig OP 6.8
Polarity
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 8 Analog Output Configuration
INF08/030 Rev. B 19
8 Analog Output ConfigurationReferring to Section 3.10 of the User Guide (IM/C1300), enter the settings required for each of the analog outputs.
8.1 Analog Output 1
8.2 Analog Output 2
8.3 Analog Output 3
8.4 Analog Output 4
Analog Output Source (enter the source required)
Analog Output Engineering Range (enter the values required)
High
Low
Analog Output Electrical Range (0 to 20 mA)(enter the values required)
High
Low
Analog Output Source (enter the source required)
Analog Output Engineering Range (enter the values required)
High
Low
Analog Output Electrical Range (0 to 20 mA)(enter the values required)
High
Low
Analog Output Source (enter the source required)
Analog Output Engineering Range (enter the values required)
High
Low
Analog Output Electrical Range (0 to 20 mA)(enter the values required)
High
Low
Analog Output Source (enter the source required)
Analog Output Engineering Range (enter the values required)
High
Low
Analog Output Electrical Range (0 to 20 mA)(enter the values required)
High
Low
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 9 Logic Equations
20 INF08/030 Rev. B
9 Logic EquationsLogic Equation 1
EQN 1.1 (operand)
EQN 1.2 (operator)
EQN 1.3 (operand)
EQN 1.4 (operator)
EQN 1.5 (operand)
EQN 1.6 (operator)
EQN 1.7 (operand)
Logic Equation 2
EQN 2.1 (operand)
EQN 2.2 (operator)
EQN 2.3 (operand)
EQN 2.4 (operator)
EQN 2.5 (operand)
EQN 2.6 (operator)
EQN 2.7 (operand)
Logic Equation 3
EQN 3.1 (operand)
EQN 3.2 (operator)
EQN 3.3 (operand)
EQN 3.4 (operator)
EQN 3.5 (operand)
EQN 3.6 (operator)
EQN 3.7 (operand)
Logic Equation 4
EQN 4.1 (operand)
EQN 4.2 (operator)
EQN 4.3 (operand)
EQN 4.4 (operator)
EQN 4.5 (operand)
EQN 4.6 (operator)
EQN 4.7 (operand)
Logic Equation 5
EQN 5.1 (operand)
EQN 5.2 (operator)
EQN 5.3 (operand)
EQN 5.4 (operator)
EQN 5.5 (operand)
EQN 5.6 (operator)
EQN 5.7 (operand)
Logic Equation 6
EQN 6.1 (operand)
EQN 6.2 (operator)
EQN 6.3 (operand)
EQN 6.4 (operator)
EQN 6.5 (operand)
EQN 6.6 (operator)
EQN 6.7 (operand)
Logic Equation 7
EQN 7.1 (operand)
EQN 7.2 (operator)
EQN 7.3 (operand)
EQN 7.4 (operator)
EQN 7.5 (operand)
EQN 7.6 (operator)
EQN 7.7 (operand)
Logic Equation 8
EQN 8.1 (operand)
EQN 8.2 (operator)
EQN 8.3 (operand)
EQN 8.4 (operator)
EQN 8.5 (operand)
EQN 8.6 (operator)
EQN 8.7 (operand)
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 10 Data Logging Configuration
INF08/030 Rev. B 21
10 Data Logging ConfigurationReferring to Section 3.12 of the User Guide (IM/C1300), enterthe settings required for data logging.
11 Pen Functions
Sample Rate ( the sample rate required)
1 second 5 seconds 10 seconds
30 seconds 60 seconds 5 minutes
10 minutes 30 minutes 1 hour
6 hours
Pre-logging Filter Type ( the rate required)
Instantaneous
Max./Min.
New File Creation ( the creation interval required)
Standard
On Pen Return
Instrument Tag (enter the tag required)
Pen 1 Short Tag (enter the tag required)
Pen 2 Short Tag (enter the tag required)
Pen 3 Short Tag (enter the tag required)
Pen 4 Short Tag (enter the tag required)
Pen 1 ( the box required)
Off
Trend
Event
Pen Source
Pen 2 ( the box required)
Off
Trend
Event
Pen Source
Pen 3 ( the box required)
Off
Trend
Event
Pen Source
Pen 4 ( the box required)
Off
Trend
Event
Pen Source
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 12 Maths Configuration
22 INF08/030 Rev. B
12 Maths Configuration12.1 Math Block 1
12.2 Math Block 2
Math Block Type ( the box required)
Standard Equation
Relative Humidity
Mass Flow 1
Mass Flow 2
High Value
Low Value
Real Time Average
Standard Math Block
Element 1 (Operand)
Element 2 (Operator)
Element 3 (Operand)
Element 4 (Operator)
Element 5 (Operand)
Element 6 (Operator)
Element 7 (Operand)
Available Operators
Median
Low Select
High Select
Divide
Multiply
Subtract
Add
End
Mass Flow 1 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
Mass Flow 2 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
High Value Math Block
Source
Reset Source
Low Value Math Block
Source
Reset Source
Relative Humidity Math Block
Bulb 1 Source
Bulb 2 Source
Average Math Block
Input
Time
Reset Source
Math Block Type ( the box required)
Standard Equation
Relative Humidity
Mass Flow 1
Mass Flow 2
High Value
Low Value
Real Time Average
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 12 Maths Configuration
INF08/030 Rev. B 23
12.3 Math Block 3
Standard Math Block
Element 1 (Operand)
Element 2 (Operator)
Element 3 (Operand)
Element 4 (Operator)
Element 5 (Operand)
Element 6 (Operator)
Element 7 (Operand)
Available Operators
Median
Low Select
High Select
Divide
Multiply
Subtract
Add
End
Mass Flow 1 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
Mass Flow 2 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
High Value Math Block
Source
Reset Source
Low Value Math Block
Source
Reset Source
Relative Humidity Math Block
Bulb 1 Source
Bulb 2 Source
Average Math Block
Input
Time
Reset Source
Math Block Type ( the box required)
Standard Equation
Relative Humidity
Mass Flow 1
Mass Flow 2
High Value
Low Value
Real Time Average
Standard Math Block
Element 1 (Operand)
Element 2 (Operator)
Element 3 (Operand)
Element 4 (Operator)
Element 5 (Operand)
Element 6 (Operator)
Element 7 (Operand)
Available Operators
Median
Low Select
High Select
Divide
Multiply
Subtract
Add
End
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 12 Maths Configuration
24 INF08/030 Rev. B
12.4 Math Block 4Mass Flow 1 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
Mass Flow 2 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
High Value Math Block
Source
Reset Source
Low Value Math Block
Source
Reset Source
Relative Humidity Math Block
Bulb 1 Source
Bulb 2 Source
Average Math Block
Input
Time
Reset Source
Math Block Type ( the box required)
Standard Equation
Relative Humidity
Mass Flow 1
Mass Flow 2
High Value
Low Value
Real Time Average
Standard Math Block
Element 1 (Operand)
Element 2 (Operator)
Element 3 (Operand)
Element 4 (Operator)
Element 5 (Operand)
Element 6 (Operator)
Element 7 (Operand)
Available Operators
Median
Low Select
High Select
Divide
Multiply
Subtract
Add
End
Mass Flow 1 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 13 Set Up Timer
INF08/030 Rev. B 25
13 Set Up Timer13.1 Timer 1
Mass Flow 2 Math Block
Input A
Input t
Temp Units
Temp Reference
Input P
Pressure Reference
Scaling Constant
High Value Math Block
Source
Reset Source
Low Value Math Block
Source
Reset Source
Relative Humidity Math Block
Bulb 1 Source
Bulb 2 Source
Average Math Block
Input
Time
Reset Source
Timer 1 ( the box required)
On
Off
Day Enable ( the box required)
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
On Hour ( the box required)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
ALL
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration 13 Set Up Timer
26 INF08/030 Rev. B
13.2 Timer 2
On Minute
Timer Duration
Hours
Minutes
Timer 2 ( the box required)
On
Off
Day Enable ( the box required)
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
On Hour ( the box required)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
ALL
On Minute
Timer Duration
Hours
Minutes
C1300 Advanced Circular Chart RecorderC1300 Custom Configuration Notes
INF08/030 Rev. B 27
Notes
INF0
8/03
0R
ev. B
ABB has Sales & Customer Support expertisein over 100 countries worldwide
www.abb.com
The Company’s policy is one of continuous product improvement and the right is reserved to modify the
information contained herein without notice.
Printed in UK (07.12)
© ABB 2012
ABB LimitedOldends Lane, StonehouseGloucestershireGL10 3TAUKTel: +44 (0)1453 826661Fax: +44 (0)1453 829671