infoplc net cx appnote 001
Post on 03-Apr-2018
223 Views
Preview:
TRANSCRIPT
-
7/28/2019 Infoplc Net CX AppNote 001
1/13
Application Notes
Gateway from Beckhoff to AB via DeviceNet
CX-AppNote-001
1.0
4 October 2007
This document explains how to connect a CX1500-B520 to an AB Controller and configure it for
the first time. This document assumes the reader is familiar with the TwinCAT System Manager
software and as well as the AB PLC software, RS Logix5000.
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
2/13
4 October 2007 Beckhoff Application Notes 2
Gateway from Beckhoff to AB via DeviceNet
Overview
Sample Files
1.DNET.tsm
2.CX1500B520.acd
3.CX1500-B520.eds
www.infoPLC.net
ftp://Customer:Customer@64.122.66.177/Application%20Notes/web/cx-appnote-001/DNet.tsmftp://Customer:Customer@64.122.66.177/Application%20Notes/web/cx-appnote-001/CX1500B520.acdftp://Customer:Customer@64.122.66.177/Application%20Notes/web/cx-appnote-001/CX1500-B520.edsftp://Customer:Customer@64.122.66.177/Application%20Notes/web/cx-appnote-001/CX1500-B520.edsftp://Customer:Customer@64.122.66.177/Application%20Notes/web/cx-appnote-001/CX1500B520.acdftp://Customer:Customer@64.122.66.177/Application%20Notes/web/cx-appnote-001/DNet.tsm -
7/28/2019 Infoplc Net CX AppNote 001
3/13
4 October 2007 Beckhoff Application Notes 3
Gateway from Beckhoff to AB via DeviceNet
Procedure
Initialization
This procedure is completed in two steps. The first step is to configure the CX. The sec-
ond is to configure the AB DeviceNet scanner card along with RSLogix 5000. In this
example one DeviceNet cable with an external terminating resistor built into the connec-
tor is used.
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
4/13
4 October 2007 Beckhoff Application Notes 4
Gateway from Beckhoff to AB via DeviceNet
TwinCAT Configuration
Open TwinCAT System Manager and open a new, blank session.
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
5/13
4 October 2007 Beckhoff Application Notes 5
Gateway from Beckhoff to AB via DeviceNet
Then, select "Choose Target", and "Search Ethernet".
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
6/13
4 October 2007 Beckhoff Application Notes 6
Gateway from Beckhoff to AB via DeviceNet
Once "Search Ethernet" is selected, select "Broadcast Search". This sends out a broad-
cast ADS search. All ADS devices on the network will reply. Select the CX, click "IP
Address", then "Add Route". Type your username and password. (By default the WINce
username is "Administrator" and the password is left blank. The WINxpe username is
"Administrator" and the password is: 1.) Click "Close", select the device, and click "OK".
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
7/13
4 October 2007 Beckhoff Application Notes 7
Gateway from Beckhoff to AB via DeviceNet
Now scan in the IO. Right click on "I/O Devices" and choose "Scan Devices".
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
8/13
4 October 2007 Beckhoff Application Notes 8
Gateway from Beckhoff to AB via DeviceNet
You will receive the following message: Hint: Not all devices will be found automatically.
Click "OK". Now choose the devices you wish to scan into the System Manager. This
exercise will only use the CX1500-B520 and the local CX1100. Click "OK".
Choose "Yes" to scan for boxes, then choose "OK" for the selected Baudrate.
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
9/13
4 October 2007 Beckhoff Application Notes 9
Gateway from Beckhoff to AB via DeviceNet
After scanning devices the System Manager should look similar to the one below. The
CX1500-B520 will have 8 bytes in and 8 bytes out. This is important to know because
later it will be scanned with the Rockwell controller.
Activate this configuration and put this system into run mode.
TwinCAT setup is now complete.
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
10/13
4 October 2007 Beckhoff Application Notes 10
Gateway from Beckhoff to AB via DeviceNet
Configuration of the Rockwell Devices
Open a new instance of RSNetworx and scan the network. Be sure the correct EDS file
has been downloaded.
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
11/13
4 October 2007 Beckhoff Application Notes 11
Gateway from Beckhoff to AB via DeviceNet
Right click the unknown device and register it.
www.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
12/13
4 October 2007 Beckhoff Application Notes 12
Gateway from Beckhoff to AB via DeviceNetwww.infoPLC.net
-
7/28/2019 Infoplc Net CX AppNote 001
13/13
4 October 2007 Beckhoff Application Notes 13
Gateway from Beckhoff to AB via DeviceNet
Right click the scanner card, click "properties", and "Download".
Save this file and open a new RSLogix 5000 session. Add a DeviceNet card and point it
to the RSNetworx file you just saved. Apply and go online.
www.infoPLC.net
top related