integrated access control integrations...ct-v900-a #1 ct-v900-a #2 ct-v900-a 2-door controller...
Post on 25-Oct-2020
1 Views
Preview:
TRANSCRIPT
Z1: 1K Ohm Z2: 2.2K Ohm
EOL1K Ohm
Optional Loop Supervision
MagneticDoor Contact
Request-to-Exit Button (EXIT-BLP)
+-
+-
+
-
+
-
+-
+-
+
-
!Always consult the regulatory agency in your area for existing regulations regarding doors designated as emergency exits.
!Reader wiring may differ from diagram. Please consult your documentation for details.
USB/RS232 to RS-485 Converter
CA-A360-USBRS
Lock Control Module (optional)
CA-A110-P
All the specifications on this document (photos, drawing, features and dimensions) could be changed without prior notice.CENTAUR_PE_V4 - Printed in Canada - March 2014
GND
GND
A1+
B1- GND
GND
A2+
B2-
INTEGRATED ACCESS CONTROL
Workstation license (CS-WSLIC-USB5):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules.
Every Centaur edition includes a Centaur Server with an administration console, plus all these software modules:Pro-Report with Tracker: On demand, scheduled or customized reportsFrontView: Live interactive floor plansFrontGuard: Display real-time visual authenticationFrontDesk: Create, modify, delete and print cards, include Photo-IDLocator: Monitor real-time location of each card holderWavePlayer: Play a sound on any system event
LCD DisplayCK-TRAK-L
(Max. 8 per CT-V900-A)
Elevator ControllerCA-A480-A
(Max. 8 per CT-V900-A)
Relay Expansion ModuleCA-A460-P(Max. 2 perCT-V900-A)
2-Door Expansion ModuleCA-A470-A
(Max. 3 per CT-V900-A)
E-bus NEtwork CapaCity & ModulEs
CoNtrollEr iNputs (up to 16 pEr CoNtrollEr)
+-Power
Supply
+-Power
Supply
Connect directly to controller lock terminals
ElECtroMagNEtiC loCk or door strikE optioN
alarM souNdEr
2-door CoNtrollEr
Ct-V900-a
R1/DO
GND
R1/D112VOUT1OUT2OUT5
GREEN
BLACK
WHITEREDYELLOW (green LED)ORANGE (red LED)BROWN (buzzer)
Blue (Clock) Not applicable with Centaur System
R2/DO
GND
R2/D112VOUT3OUT4OUT6
DO
-
D1+V (green LED)R (red LED)B (buzzer)
H (Clock) Not applicable with Centaur System
Connect earth terminal toa certified earth ground
Transformater CDVI15024 Vac, 75VAAlso includes an output of16 VAC (75 VA) that can power up to 32-door expansion modules CA-A470-A
2 batteries(12V, 7AH)
connected in series for 24V backup
Tamper Switch N.C. Contact
To next controller of a site.
MODULE NETWORK(E-BUS RS-485)Furthest module can be installed up to 1220M (4000ft) away from the CT-V900-A controller
PolycarbonateProximityReaderDGLP FN WLC26
Stainless SteelProximity Reader
DGLI WLC26
CoNtrollEr NEtwork(rs-485)
CT-V900-A2-Door Controller
P O S I T I O N
GNDTXB-
+12V
RXG
NDA+G
ND
RECEIVE
TRANSMIT
POWER
CA-A360-A
CONVERTERSETTINGS
EOL= ON
Bias High/Low JumpersA+= LowB-= Low
CONTROLLER #2 SETTINGS
EOL= OFF
Bias High/Low JumpersA+= HighB-= High
CONTROLLER #1 SETTINGS
EOL= OFF
Bias High/Low JumpersA+= HighB-= High
CONTROLLER #3 SETTINGS
EOL= ON
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)
END POINTof the RS-485 controller network
CT-V900-A #1
CT-V900-A #2
CT-V900-A2-Door Controller
CT-V900-A #3
CT-V900-A2-Door Controller
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
RS-2327.6m (25ft) max.
Dipswitch Setting
Dipswitch Setting
Dipswitch Setting
Example of Jumper Settings
HIGH
HIGH
EOL
EOL
LOW
LOW
Jumper set to LOW
Jumper set to HIGH
Jumper set to EOL ON
Jumper set to EOL OFF
ON
ON
OFF
OFF
BATT
BATTJumper set to OFF
Jumper set to ON
CONTROLLER NETWORK JUMPERS
ADDRESSABLE DIPSWITCH
E-BUSNETWORK JUMPERS
CT-V900-A CUT VIEW
At the START POINT and the END POINT of the RS-485 controller network, the devices’ EOL jumpers= ON. All devices‘ in between EOL= OFF
Note: If you do not use a converter, the first CT-V900-A controller will be the START POINT.
At the START POINT of the RS-485 controller network, the device HIGH/LOW Bias jumpers is set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Real-Time ClockLithium Battery Setting
S E R V E R
CoNtrollEr NEtwork
JuMpEr & dipswitCh sEttiNgs
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
EOL= OFF
Bias High/LowA+= HighB-= High
EOL= OFF
Bias High/LowA+= HighB-= High
EOL= OFF
Bias High/LowA+= HighB-= High
EOL= ON
Bias High/LowA+= HighB-= High
EOL= ON
Bias High/Low JumpersA+= LowB-= Low
START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)
END POINTof the RS-485 E-bus network
CT-V900-A2-Door Controller
CT-V900-A
CA-A480-A CA-A480-A
CA-A470-A CA-A470-A
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF
At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Dipswitch Setting
Dipswitch Setting
Dipswitch Setting
Dipswitch Setting
E-bus NEtwork JuMpEr & dipswitCh sEttiNgs
Fire alarm contact for Lock1 & Lock2
DestinationReporting Module
CA-A482-PThe DRM connects directly to
the CA-A480-A, elevator controller
TCP/IP ModuleCA-ETHR-A
RS-485 Network HubCA-A370-P
sErVEr to CoNtrollEr CoMMuNiCatioN
Optional NetworkedWorkstation
First controllerof a site
(CT-V900-A)
1 Transformer16 VAC, 40VA
50/60Hz Class 2and
1 battery (12V, 7AH) perCA-A480-A & CA-A470-A
Centaur Integrated Access ControlSystem Overview
1637 Highway 440 West, Laval, Quebec, Canada, H7L3W3 Tel.: (450) 682-7945, Toll Free Tel.: 1-866-610-0102, Fax: (450) 682-9590, Toll Free Fax: 1-866-682-9590
The installer’s choice
ISO - Thin card for printing (ISO)
CS - Standard clamshell card
Visitor ManagementCentaur Visitor Management preserves a complete record of all visitor activities and keeps each visitor’s information for subsequent visits. Centaur Visitor Management will allow you to securely control the comings and goings of all visitors.
Parking ManagementThe Centaur Parking Management provides you with a real time parking activity monitor. It allows you to quickly see how many parking places are used, by which user and how many parking spaces are available.
Guard Tour FeatureLive interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive reports.
Asset ManagementWhy buy something that you already have? Keep track of your assets and save time and money. Find quickly who is in possession of your assets. A report can be generated and sent automatically via email.
INTEGRATED ACCESS CONTROL
* FREE from our web site, www.cdvi.ca (Security dongle NOT required)
STARTER PACK*
(FREE)LITE STANDARD PROFESSIONAL ENTERPRISE GLOBAL
Sites 1 1 64 64 64 64
Serial Ports 4 1 1 1 4 4
Dial Up connection ✔ ✔ ✔ ✔ ✔ ✔
TCP/IP connection ✔ ✔ ✔ ✔ ✔ ✔
Cards (per site) 512 512 2,048 8,196 16,384 16,384
Controllers (per site) 1 16 32 64 256 256
Doors (per site) 8 16 128 512 2048 2048
Elevator Control ✔ - ✔ ✔ ✔ ✔
Elevator Cabs (per site) 2 - 64 128 512 512
Floors per cab 64 - 64 64 64 64
Floor groups (per site) 128 - 128 128 128 128
Include built-in Integration ✔ - ✔ ✔ ✔ ✔
Global Communication - - - - - ✔
Global User Groups - - - - - 2048
Global Access Levels - - - - - 256
Global Schedules - - - - - 256
Additional Workstation License - - - 1 1 1
Software Editions V5.2
INTEGRATIONSDVR IntegrationCentaur DVR integration can associate a specific access control event with a video recording and lets you playback up to 60 seconds before and after that event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format.
top related