User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
Experience In Motion
Installation Operation
Maintenance
RG Series Standard ActuatorFCD AXENIM0122-00 12/09
USER INSTRUCTIONS
-
2
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
1 Using Flowserve Valves, Actuators and Acces-sories Correctly
1.1 General usage
Thefollowinginstructionsaredesignedtoassistinunpacking,installingandperformingmaintenanceasrequiredonFLOWSERVEproducts.Productus-ersandmaintenancepersonnelshouldthoroughlyreviewthisbulletinpriortoinstalling,operatingorperforminganymaintenance.
InmostcasesFLOWSERVEvalves,actuatorsandaccessoriesaredesignedforspecificapplicationswithregardtomedium,pressureandtemperature.Forthisreasontheyshouldnotbeusedinotherap-plicationswithoutfirstcontactingthemanufacturer.
1.2 Terms concerning safety
The safety termsDANGER, WARNING, CAUTIONandNOTEareusedintheseinstructionstohighlightparticulardangersand/ortoprovideadditionalinfor-mationonaspectsthatmaynotbereadilyapparent.
DANGER: indicates that death, severe personal injury and/or substantial property damage will occur if proper precautions are not taken.
WARNING: indicates that death, severe personal injury and/or substantial property damage can occur if proper precautions are not taken.
CAUTION:indicates that minor personal injury and/or property damage can occur if proper precautions are not taken.
NOTE: indicates and provides additional technical information, which may not be very obvious even to qualified personnel.
Compliancewith other, not particularly emphasisednotes,withregardtotransport,assembly,operationandmaintenanceandwithregardtotechnicaldocumentation(e.g.intheoperatinginstruction,productdocumentationorontheproductitself)isessential,inordertoavoidfaults,whichinthemselvesmightdirectlyorindirectlycauseseverepersonalinjuryorpropertydamage.
1.3 Protective clothing
FLOWSERVEproducts are often used in problematicapplications(e.g.extremelyhighpressures,dangerous,toxicorcorrosivemediums).Inparticularvalveswithbellows seals point to such applications.When per-formingservice,inspectionorrepairoperationsalwaysensure,thatthevalveandactuatoraredepressurisedandthatthevalvehasbeencleanedandisfreefromharmfulsubstances. In such casespayparticular attention topersonalprotection(protectiveclothing,gloves,glassesetc.).
1.4 Qualified personnel
Qualifiedpersonnelarepeoplewho,onaccountoftheirtraining,experienceandinstructionandtheirknowledgeofrelevantstandards,specifications,accidentpreventionregulationsandoperatingconditions,havebeenauthor-isedbythoseresponsibleforthesafetyoftheplanttoperformthenecessaryworkandwhocanrecogniseandavoidpossibledangers.
1.5 Installation
DANGER: Before installation check the order-no., serial-no. and/or the tag-no. to ensure that the valve/actuator is correct for the intended application.
Donotinsulateextensionsthatareprovidedforhotorcoldservices.
Pipelinesmustbecorrectlyalignedtoensurethatthevalveisnotfittedundertension.
Fireprotectionmustbeprovidedbytheuser.
1.6 Spare parts
UseonlyFLOWSERVEoriginalspareparts.FLOWSERVEcannotacceptresponsibilityforanydamagesthatoc-curfromusingsparepartsorfasteningmaterialsfromothermanufactures.IfFLOWSERVEproducts(especiallysealingmaterials)havebeenonstoreforlongerperiodschecktheseforcorrosionordeteriorationbeforeusingtheseproducts.FireprotectionforFLOWSERVEproductsmustbeprovidedbytheenduser.
STOP!
INDEX
1 Using Flowserve Valves, Actuators and Ac-cessories Correctly
2 Installation3 Travel Stop Adjustments4 Maintenance Instructions5 Field Conversion from Fail CW to Fail CCW6 Torque Shaft7 Long Term Storage
-
3
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
1.7 Service / repair
To avoid possible injury to personnel or damage toproducts, safety termsmust be strictly adhered to.Modifying thisproduct,substitutingnonfactoryparts,orusingmaintenanceproceduresother thanoutlinedinthisinstructioncoulddrasticallyaffectperformanceandbehazardoustopersonnelandequipment,andmayvoid existingwarranties. Between actuator and valvethere aremovingparts. To avoid injury FLOWSERVEprovides pinch-point-protection in the formof coverplates,especiallywhereside-mountedpositionersarefitted.Iftheseplatesareremovedforinspection,serviceorrepairspecialattentionisrequired.Aftercompletingworkthecoverplatesmustberefitted.
Apartfromtheoperatinginstructionsandtheobligatoryaccident prevention directives valid in the country ofuse, all recognised regulations for safety and goodengineeringpracticesmustbefollowed.
WARNING: Before products are returned to FLOWSERVE for repair or service FLOWSERVE must be provided with a certificate which confirms that the product has been decontaminated and is clean. FLOWSERVE will not accept deliveries if a certificate has not been pro-vided (a form can be obtained from FLOWSERVE).
1.8 Storage
InmostcasesFLOWSERVEproductsaremanufacturedfromstainlesssteel.Productsnotmanufacturedfromstainlesssteelareprovidedwithanepoxyresincoating.ThismeansthatFLOWSERVEproductsarewellprotectedfrom corrosion.Nevertheless FLOWSERVE productsmustbestoredadequatelyinaclean,dryenvironment.Plastic caps are fitted to protect the flange faces toprevent the ingress of foreignmaterials. These capsshouldnotberemoveduntilthevalveisactuallymountedintothesystem.
1.9 Valve and actuator variations
Theseinstructionscannotclaimtocoveralldetailsofall possible product variations, nor can they provideinformationforeverypossibleexampleofinstallation,operation or maintenance. This means that theinstructions normally include only the directions tobe followed by qualified personalwhere the productisbeingused for isdefinedpurpose. If thereareanyuncertaintiesinthisrespectparticularlyintheeventofmissingproduct-relatedinformation,clarificationmustbeobtainedviatheappropriateFLOWSERVEsalesoffice.
1.10 Unpacking
Each delivery includes a packing slip. Whenunpacking,checkalldeliveredvalvesandaccessoriesusingthispackingslip.
Reporttransportdamagetothecarrierimmediately.
In case of discrepancies, contact your nearestFLOWSERVElocation.
STOP!
-
4
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
Introduction TheRGSeriesisafullymodulardesign,scotch-yokeac-
tuator;withtorquerangefrom2000Nmto250,000Nm(2,800 in-Lbs to 2.2M in-Lbs) in eightmodels, RG1through RG8, with maximum actuator torque andmountingbaseincompliancewithISO5211.
TheRGseriesSpringReturnActuators,incontrastwithR-series,usePull-to-Compressthespringdesign.
2 Installation
2.1 All actuators are factory lubricated for life, but stillshouldbeprotected fromtheelementsandstored in-doorsuntilreadyforuse.Theportsoftheactuatorarepluggedassupplied from the factory. If actuatorsarestoredforalongperiodoftimepriortoinstallation,fol-lowtheLongTermStorageinstructions.
2.2 Prior to assembly, manually open and close valve (ifpossible), to ensure freeness of operation. Be sure,valveandAutomaxactuatorrotateinthesamedirectionandareinthesameposition(i.e.,valveclosed,actuatorclosed).
2.3 Check the mounting surfaces, the stem adaptor andthebrackettoassureproperfit.Securethevalveintheclosedpositionwiththestemvertical.Boltthebracketto the valve and place the stem adaptor on the valvestem.Positiontheactuatoroverthevalveandlower,toengage the stem adaptor to the actuators bore. Con-tinue to lower until the actuator seats on the bracketmounting surface. In order to align the bolt holes, itmaybenecessarytoloosenthevalve-to-bracketboltingtoallowmoreplay inthebracket.Themountingboltsshouldeasilyfitintotheboltholeswithoutanybinding.Ifneeded,turnorstroketheactuatorafewdegreesand/oradjusttheactuatortravelstops.Bolttheactuatortothebracket.
2.4 Adjustthetravelstopboltsoftheactuatorfortheproperopenandclosedvalvepositions,pervalvemanufactur-ersrecommendations.Pneumaticallystroketheactua-
torseveraltimestoassureproperoperation.Thestemadaptorshouldnotbindduringoperation.Iftheactua-tor isequippedwithanUltraSwitchorotheraccesso-ries,adjustthematthistime.
2.5 Toprolongactuatorlifeuseonlyclean,dryplantair.Lu-bricatedairisnotrequired,howeveritisrecommendedparticularlyforhighcycleapplications.Donotuselubri-catedairwithpositioners.
CAUTION! Lifting bolts holes on the actuator are for lifting the actuator modules only with eye bolts, not a complete valve and actuator assembly.
3 Travel Stop Adjustments
Allactuatedvalvesrequireaccuratetravel-stopadjust-ments at both ends of the stroke to obtain optimumperformance and valve seat life. The accumulation oftolerancesintheadaptionofactuatorstovalvesissuchthattheremustbearangeofadjustmentsforbothendsofthestroketoachieveoptimumperformance.
TheRGactuatorshavetravelstopadjustmentsinboththe clockwise and counter-clockwise directions. The+/-3degreeadjustmentfeatureprovidesshaftrotationfrom84to96degrees.
4 Maintenance Instructions
4.1 Disassembly Instructions
4.1.1 Disconnectallairandelectricalsuppliesfromactuator.
4.1.2 Removeallaccessoriesfromactuatoranddismountac-tuatorfromvalve.
4.1.3 DrawingReferences:Drg#263188,Drg#263189
4.2 Spring Module (see Fig.: 1)
CAUTION! Personal Injury may result if Step 2 is at-tempted before Step I is completed.
Fig.: 1 Spring Module
4 2
4 2
CW
CWW
Actuator Configuration
-
5
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
4.2.1 Applyairpressuretoport2onFCW(port4onFCCW)actuator, raising pressure slowly, enough to releasespringpressurefromtheStopBolt(17).BackofffullybothStopBoltsontheTorqueModuleandreleaseairpressure.Thiswillrelievethespringpreload.
4.2.2 TheSpringModule isweldedintoan integralcompo-nentandcannotbedisassembled.Toremovefromac-tuator,removeSpringModuleendcover(60)andus-inganextendedsocketspanner/tubespanner,unscrewanddisconnectthePullRod(54)fromtheTorqueMod-ule.
CAUTION! Take extra care not to drop the socket/small
tools inside the spring can. Small objects dropped in-side may fall through the spring guide and get stuck in the spring coils.
NOTE: A retainer ring on the threaded side of the Pull Rod stops it from being removed completely from the Spring Module.
4.2.3 SlingtheSpringModuleusingliftingboltsontheMod-uleandremovetheAdapterNuts(19)andLockwash-ers(20).SpringModulecannowberemovedfromtheTorqueModule.
4.2.4 BeforereassemblingSpringModuletobody,makesurestud threadsarecleanof anydirt, shavings,orotherdebris.Cleanthreadswithragandsolventifrequired,andlubricatethreadswithananti-seizecompound.
NOTE: Support the Spring Module during removal so as not to damage the Pull Rod and the studs threads.
4.3 Pressure Module
4.3.1 Pressurizerodendofcylinder,enoughtostroketoend.Ventouttheairfromthecylinder.
4.3.2 Remove end cover plate/plug from pressure moduleandunscrewthepistonrodwithasocket/tubespanner.
4.3.3 Slingthepressuremodulefromtheeyebolts,removetheAdaptorStudNuts(19)andLockwashers(20)andtakethePressuremoduleofftheTorquemodule.
4.3.4 RemovetheTieRodNuts(37),theEndPlate(33)andTieRods(36).
4.3.5 SlidetheCylinder(34)overandoffthePiston(38),be-ingcarefulnottoscratchordentthehonedandchromeplatedsurfaceofthecylinder.
4.3.6 Slide out the Piston- Piston Rod assembly off theAdapterPlate(32).
4.3.7 Remove theRetainerRing(40)and take theSplitCollar(39)offthePistonRod(35).PullthePistonRodoffthePiston.
4.4 Torque Module (Body Group)
NOTE: Spring Module and Pressure Module must be removed before disassembling the Torque Module
4.4.1 RemovetheIndicator(29),iffitted.
4.4.2 RemoveTopCoverBolts(65)andthecover,O-ringandtheNamurShaftAssembly(15).
4.4.3 RemoveBodyCoverBolts,LockWashers(26)andThreadPlugs(31).
4.4.4 UsingtheremovedBodyCoverBolts,jackopenthecoverby threading in thebolts in the two tappedholesuntilcoverisseparatedenoughtopryapart.Takecare to jack theboltsevenly,as thecover ispositionedby four dowel pins, and cross loadingmaycausebending/breakageofpinsonsmallac-tuatorsizes.
4.4.5 GentlytapwithPU/PlastichammerandpullofftheGuideBar(2)fromthebody.
4.4.6 LiftYokeSubAssemblyoutofbodybore.
4.4.7 RemoveDelrinPlate(7)retainingscrews.PullouttheYokePin(9),andSliderBlock(10).
4.4.8 SlideouttheGuideBlock(11)outoftheYokeandremovethebottomSliderBlock.
4.4.9 Remove Yoke Seals (5) and Yoke Bushing (4) ifwornout/damaged.
4.5 Reassembly Instructions
4.5.1 Inspect all parts for wear and replace any wornparts as needed. Normally, all O-rings and sealsshouldbereplacedwhenreassemblinganactuator.Useseallubricant,DowCorning55foralllubrica-tioninthepressuregroup.
Ensure the replacement seals are suitable for theservicetemperature.
4.5.2 TheMetalbackedbronze-ptfebearingsmaybein-spectedandassessedforreplacement,referringtoguide(seeFig.:2)ontheusefulresiduallife
Toreplacethebearings,theunitorthesubassembly
-
6
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
needstobebroughtintoworkshop,withsuitablefacilities to carefully remove the bearing withoutdamaging the housing and to press new bearingwithproperpressing toolspermanufacturers in-structionsandapress.
Donotattempttopryoutanyofthebearingsintheactuatorwithsharptools,orhammerinareplace-mentbearing.
4.5.3 Clean thoroughly and grease all Torque Modulecomponents with NLGI grade 2 multi-purposegrease.UseShellAlvaniaEP2forStandardActua-tors.Forlowtemperatureunits,useDow55greaseorequivalent.
4.5.4 Reverse thedisassemblyprocedures to reassem-ble.Applyrecommendedtorque,refertorquechart,ontheTieRodLocknuts,theMountingFlangeNuts,theBodyCover&TopPlatebolts,thePistonRod/PullRod(seetablesonpafe7.
The Tie Rod and Mounting Flange Stud threadsshouldbelubricatedwithLocktiteAntiseize,77164orequivalent.
ThePull/PistonRodthreadsandcoverboltstobetightenedwiththreadlockcompound,Loctite243orequivalent.
4.5.5 Refer to parts andmaterials drawings for all re-quiredspareparts(seepages9+10).
Test the actuator for smooth operation and airleakageatservicepressurebeforereinstallingintoservice.
5 Field Conversion from Fail CW to Fail CCW (ForSpringReturnActuators)
TheRGspringreturnactuatorcanbeconvertedfromfailCWtofailCCWeasily,withouthavingtoremovetheTorqueModule,mounting bracket, stem adaptor andthe shaft driven accessories, mounted on the centrebody.SimplyswitchthepositionsofthePressureandSpringModules.
ActuatorDesignationneedstobesuitablychangedonthenameplate.
Followstepsbelow,ifoperatingthevalveispermitted:
5.1 Apply enough air pressure to the actuator to relievespringloadonthestopperbolt.
5.2 BackoffboththestopperboltsontheTorqueModuleanddepressurizetheactuator.
5.3 RemoveSpringModule end cover, unscrew and dis-connecttheSpringPullRod.
5.4 Pressurize rod end of Pressure Module, to end ofstroke. Depressurize and remove the end cover/plugon the PressureModule. Use a tube/socket spanner,loosenpistonrodbyoneturn,fitbackendcover/plugandpressurizecapend,enoughtostroketoend.De-pressurize, removeendcover/plug and fullyunscrewanddisconnectthepistonrodfromtheTorqueModule.
5.5 RemovethePressureandSpringModulesofftheTorqueModulebyremovingthemountingflangestudnuts.
Fig.: 2 Residual Life Guide
-
7
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
5.6 Switchthepositionsofthetwomodules,connectthePressureModulefirstandensuretheportsareonthestopperboltssideofactuator.Threadinandtorquethepiston rod to recommendedvalue, fitbackendcoverplate/plug.Pressurizecapendtostroketheactuatortoend.
5.7 ReinstallSpringModule,torquethepullrodtorecom-mendedvalue,fitendcoverback.Pressurizerodendofcylinderandadjustthestopperbolts.
5.8 Checkactuatorforproperoperation,attheratedwork-ingpressure.
NOTE: If operation of valve is not permitted, during changing of the Fail Safe direction, then the actuator needs to be taken off the valve and reconfigured, as explained above.
Fastner Model RG1 RG2 RG3 RG4 RG5 RG6 RG7 RG8
Mounting Flange Nut
ThreadSize M8 M10 M12 M12 M16 M16
Tightningtorque
ftLb 10-12 18-22 30-35 30-35 80-90 80-90 140-160 280-320
kgm 1.4-1.7 2.5-3.0 4.2-4.8 4.2-4.8 11.0-12.5 11.0-12.5 19-22 38-44
Body Cover Bolts
ThreadSize M6 M6 M8 M8 M10 M10
Tightningtorque
ftLb 3-5 3-5 10-14 10-14 18-22 18-22 26-30 26-30
kgm 0.5-0.7 0.5-0.7 1.4-2.0 1.4-2.0 2.5-3.0 2.5-3.0 3.5-4.0 3.5-4.0
Top Plate Bolts
ThreadSize M6 M6 M8 M8 M10 M10
Tightningtorque
ftLb 3-5 3-5 10-14 10-14 18-22 18-22 22-26 22-26
kgm 0.5-0.7 0.5-0.7 1.4-2.0 1.4-2.0 2.5-3.0 2.5-3.0 3.0-3.5 3.0-3.5
Stopper Bolt Locknuts
ThreadSize M16 M20 M20 M30 M36 M48 M56 M64
Tightningtorque
ftLb 75-85 90-100 90-100 100-110 120-130 140-150 175-200 200-240
kgm 10-12 12-14 12-14 14-15 16-18 19-21 25-28 28-33
Piston Rod/Pull Rod
HexSize,A/F 18 18 24 30 36 46 65 85
Tightningtorque
ftLb 30-35 35-45 50-60 60-75 75-85 100-140 175-200 200-240
kgm 4-5 4-5 7-8 8-10 10-12 13-19 24-28 28-33
Bolt Torques
Cylinder Size (in.) 5 6 7 8 9 10 12 14 16 18 20 22 24 28 32 32T 36 36T 40
Tie Rod Nut Size M10 M10 M10 M10 M12 M12 M16 M16 M20 M20 M24 M24 M30 M30 M30 M36 M30 M36 M30
Tightening Torque (ft Lb)
8 11 14 19 28 34 64 88 143 181 268 325 485 330 431 1028 564 876 673
Tie Rod Nut Torque
-
8
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
How to Order
SeriesBody Size
Cylinder Size ActionSpring Module
Torque Pattern (Yoke)
Sealing/Temp Manual Override Material/ Coatings Options
RG
1 05 06 07 08 09 10 12 DA- DoubleActing SingleCylinder 0 S- Symmetrical N- Nitrile,-20Fto180F
0- None GE- GreyEpoxy(std) 00- None
2 08 09 10 12 14 16 DD- DoubleActing DualCylinder 1 C- Canted G- SandwichDeclutchGbox PO- PrimerOnly TC- Ext.Stopper-CW
3 10 12 14 16 18 20 2 H- HighTemp(Viton),0Fto300F
J- Jackscrew WE- WhiteEpoxy TO- Ext.Stopper-CCW
4 14 16 18 20 22 24 3 D- BevelGearJackscrew SP- Specials TB- Ext.Stopper-BothDir
5 16 18 20 22 24 28 4 L- LowTemp,(material)-55Fto180F
H- Hydraulic S xxx- Specialscode
6 18 20 22 24 28 32 36 SR- SpringReturn FailCW 5
7 24 28 32 36 40 SO- SpringReturn FailCCW 6
8 28 32 36 40 7
8
Model Code Example:
RG 5 22 SR 6 C N D GE TC
Actuator Designation
Module Weights (approx.)Module Weights, Lbs (kgs)
ModelTorque Module
Pressure Module Spring Module5 6 7 8 9 10 12 14 16 18 20 22 24 28 32 36 40 1 2 3 4 5 6 7 8
RG1 68(31)
31(14)
35(16)
47(22)
53(24)
66(30)
94(43)
139(63)
88(40)
97(44)
101(46)
103(47)
106(48)
114(52)
119(54)
119(54)
RG2 99(45)
56(25)
69(32)
99(45)
143(65)
209(95)
320(145)
128(58)
145(66)
154(70)
158(72)
158(72)
172(78)
180(82)
186(85)
RG3 143(65)
100(45)
142(64)
200(91)
318(145)
406(185)
561(255)
226(103)
260(118)
267(121)
269(122)
276(125)
330(150)
321(146)
RG4 295(134)
217(99)
339(154)
427(194)
586(266)
741(337)
942(428)
402(183)
442(201)
462(210)
477(217)
510(232)
545(248)
565(257)
581(254)
RG5 510(231)
356(162)
455(207)
610(277)
853(388)
994(452)
1634(743)
639(290)
737(335)
770(350)
783(356)
901(410)
955(434)
RG6 933(423)
493(224)
616(280)
861(391)
1051(478)
1732(787)
2321(1055)
3044(1384)
1283(583)
1738(790)
1671(760)
1730(787)
2061(937)
1995(907)
RG7 1881(853)
1824(829)
2411(1096)
3156(1435)
3913(1779)
2283(1038)
2946(1339)
3043(1383)
3177(1444)
3630(1650)
3709(1686)
RG8 3718(1686)
2165(984)
2819(1282)
3372(1533)
4159(1891
4627(2103)
5800(2637)
6113(2779)
6227(2830)
7111(3232)
7423(3374)
Body SizeMax. Cylinder Size
DA DD SR/SO
1 9 8 12
2 12 10 16
3 16 14 20
4 20 16 24
5 22 20 28
6 28 24 36
7 36 32 40
8 40 40 40
-
9
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
Drawing # 263188
C
G G
16 17
181920
3233
3436
37
3844
4346 48 62 26 65
5051
52
53
5758
59 60
61
23
3165
64
8
49
54
DET
AIL
A
42
45
DET
AIL
B
56 63
68
67 19
DET
AIL
C
353940
47
SEC
TIO
N G
-G
12
3
45 67 6
5
12 13
1415
21 30 2224
26 66 28 29
41
91011
27
REV
ISIO
NS
ECO
NO
REV
ZON
ELT
R
DES
CRI
PTIO
ND
ATE
CH
K
1PU
LL R
OD
UPD
ATE
D11
/24/
09SP
ITEM
N
O.
DES
CRI
PTIO
NM
ATE
RIA
LQ
TY.
1C
ENTE
R BO
DY
AST
M A
-536
Gr 6
0-40
-18
12
GU
IDE
ROD
STEE
L A
ISI 4
340
13
CO
VER
AST
M A
-536
Gr 6
0-40
-18
14
BUSH
PTFE
BRO
NZE
25
O-R
ING
BUN
A -
N2
6YO
KEA
STM
A-5
36 G
r 60-
40-1
81
7 R
ETA
INER
DEL
RIN
28
SCRE
WST
EEL
Gr 8
.812
9PI
NST
EEL
AIS
I 434
01
10 S
LID
ER B
LOC
KB-
150-
C62
400
211
GU
IDE
BLO
CK
STEE
L A
-148
Gr.
90-6
01
12BU
SHPT
FE B
RON
ZE2
13BU
SHPT
FE B
RON
ZE2
14PL
ATE
UN
S S3
1600
115
SHA
FTU
NS
S316
001
16N
UT
STEE
L G
r 82
17ST
OP
BOLT
STEE
L G
r 8.8
2
ITEM
N
O.
DES
CRI
PTIO
NM
ATE
RIA
LQ
TY.
18ST
UD
STEE
L G
r 8.8
1219
NU
TST
EEL
Gr 8
1220
WA
SHER
STEE
L12
21O
-RIN
GBU
NA
- N
122
O R
ING
BUN
A -
N1
23O
-RIN
GBU
NA
- N
224
BUSH
PTFE
BRO
NZE
125
PIN
SA-1
93-B
74
26 W
ASH
ERST
EEL
1827
CO
VER
STE
EL A
-36
128
SCRE
WST
EEL
Gr 8
.81
29 IN
DIC
ATO
RPL
AST
IC1
30O
-RIN
GBU
NA
- N
131
SCRE
WST
EEL
Gr 8
.82
32A
DA
PTO
RA
STM
A-5
36 G
r 60-
40-1
81
33EN
D C
AP
AST
M A
-536
Gr 6
0-40
-18
134
CYL
IND
ERSA
-106
-B1
ITEM
N
O.
DES
CRI
PTIO
NM
ATE
RIA
LQ
TY.
35 P
ISTO
N R
OD
STEE
L A
ISI 4
340
136
TIE
ROD
SA-1
93-B
74
37LO
CKN
UT
STEE
L G
r 84
38PI
STO
NA
STM
A-5
36 G
r 60-
40-1
81
39SP
LIT
CO
LLA
RSA
E-41
404
40RE
T RI
NG
UN
S S3
1600
141
EYE
BO
LTST
EEL
242
BUSH
PTFE
BRO
NZE
143
QU
AD
SEA
LRU
BBER
144
WEA
R RI
NG
CA
RBO
N F
ILLE
D P
TFE
245
QU
AD
SEA
LRU
BBER
146
O-R
ING
BUN
A -
N2
47O
-RIN
GBU
NA
- N
148
CO
VER
PLA
TE S
TEEL
A-3
61
49O
-RIN
GBU
NA
- N
150
AD
APT
OR
SA -2
16-W
CB
151
PIPE
STEE
L SA
-53-
B1
ITEM
N
O.
DES
CRI
PTIO
NM
ATE
RIA
LQ
TY.
52EN
D C
AP
SA
-216
-WC
B1
53SP
RIN
G G
UID
ESA
-216
-WC
B1
54PU
LL R
OD
STEE
L A
ISI 4
340
155
EYE
BO
LTST
EEL
256
BUSH
PTFE
BRO
NZE
157
SPRI
NG
AST
M A
689
516
OH
158
SPRI
NG
AST
M A
689
516
OH
159
BOLT
M16
STEE
L G
r 8.8
460
CO
VER
STE
EL A
-36
161
WA
SHER
STEE
L4
62O
-RIN
GBU
NA
- N
163
O-R
ING
BUN
A -
N1
64BU
TTO
NU
HM
WPE
665
BOLT
STEE
L G
r 8.8
2466
PIN
CA
RBO
N S
TEEL
167
O-R
ING
BUN
A -
N2
68RE
T RI
NG
UN
S S3
1600
1
87
65
43
21
ABCD
12
34
56
78
D C B ATM
HD
AC
TUA
TOR,
RG
SER
IES
KNS
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
DD
IMEN
SIO
NS
ARE
IN M
ILLI
MET
ERS
AN
D A
RE A
FTER
PLA
TIN
G.
X. .X .XX
1 .75
.25
THIR
D A
NG
LE P
ROJE
CTI
ON
CO
PYRI
GH
T - F
LOW
SERV
E C
ORP
ORA
TIO
NA
LL R
IGH
TS R
ESER
VED
INFO
RMA
TIO
N IN
TH
IS D
OC
UM
ENT
IS C
ON
FID
ENTI
AL
AN
D IS
TH
EEX
CLU
SIV
E PR
OPE
RTY
OF
FLO
WSE
RVE
CO
RPO
RATI
ON
, DEL
IVER
YO
F TH
IS D
OC
UM
ENT
OR
AN
Y C
OPY
TH
EREO
F O
R D
ISC
LOSU
RE O
FSU
CH
INFO
RMA
TIO
N T
O U
NA
UTH
ORI
ZED
PER
SON
S IS
FO
RBID
DEN
.
DIM
ENSI
ON
S W
ITH
T
OLE
RAN
CES
ARE
IDEA
L D
ESIG
N D
IMEN
SIO
NS.
ALL
DIM
ENSI
ON
S A
ND
TO
LERA
NC
ESPE
R A
NSI
Y14
.5M
- 19
82
DO
NO
T SC
ALE
AN
GLE
S 1
/2
DRA
WIN
G N
O.
ENG
BY
CH
K BY
DRW
BY
SP
NEX
T A
SSY
REF
LAYO
UT
R U
NSP
EC R
AD
II
DES
IGN
FIL
E
MA
CH
INE
FIN
ISH
Ra
MA
TERI
AL
SIZE
6/10
/09
6/10
/09
D1REV
SCA
LESH
EET
1:10
1 O
F 1
Flo
w C
ont
rol D
ivisi
on
BGL
SITE
2631
88
3D12
Q1S
\SKA
LAN
IDH
I (11
/24/
2009
7:0
2:06
PM
)
-
10
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
Drawing # 263189
46
44*
3930
36
40#
2
336
1
48
54#
61*
57
58
50
6251
49
16 17
5*
14
24
15
26
25
28*
42*
31
35
32
12#
13#
64
23
27
34
67
59
60*
7
11
3
53
65
20*
29
19*
5321
*
53
65
47*
38
8
4#
5*
1824
67
41*
45*
9
4#
39
43*
37
37
37
10
1062
61
63*
63*
52
68
NO
TE:
SEA
L KI
TS C
ON
TAIN
* M
ARK
ED P
ART
S1.
SERV
ICE
KITS
CO
NTA
INS #
MA
RKED
PA
RTS
2.
REV
ISIO
NS
ECO
NO
REV
ZON
ELT
R
DES
CRI
PTIO
ND
ATE
CH
K
12
DPU
LL R
OD
UPD
ATE
D11
/24/
09SP
ITEM
N
O.
SHO
RTD
ESC
MA
TERI
AL
QTY
.
1C
ENTE
R BO
DY
DU
CTI
LE IR
ON
12
GU
IDE
ROD
ALL
OY
STEE
L1
3C
OV
ERD
UC
TILE
IRO
N1
4#BU
SHPT
FE B
RON
ZE2
5*O
-RIN
GBU
NA
- N
26
YOKE
DU
CTI
LE IR
ON
17
RETA
INER
PLA
STIC
28
SCRE
W S
TEEL
129
PIN
ALL
OY
STEE
L1
10SL
IDER
BLK
AL
BRO
NZE
211
GU
IDE
BLO
CK
DU
CTI
LE IR
ON
112
#BU
SHPT
FE B
RON
ZE2
13#
BUSH
PTFE
BRO
NZE
214
PLA
TEST
AIN
LESS
STE
EL1
15SH
AFT
STA
INLE
SS S
TEEL
116
NU
TST
EEL
217
STO
P BO
LT S
TEEL
2
ITEM
N
O.
SHO
RTD
ESC
MA
TERI
AL
QTY
.
18ST
UD
STE
EL12
19*
O-R
ING
BUN
A -
N1
20*
O R
ING
BUN
A -
N1
21*
O-R
ING
BUN
A -
N2
22#
BUSH
PTFE
BRO
NZE
123
PIN
ALL
OY
STEE
L4
24W
ASH
ER S
TEEL
1225
CO
VER
CA
RBO
N S
TEEL
126
SCRE
WPL
ATE
D S
TEEL
127
WO
RCES
TER
PLA
STIC
128
*O
-RIN
GBU
NA
- N
129
SCRE
WA
LLO
Y ST
EEL
230
AD
APT
OR
DU
CTI
LE IR
ON
131
CYL
IND
ERC
ARB
ON
STE
EL1
32EN
D C
AP
DU
CTI
LE IR
ON
133
PIS
TON
RO
DA
LLO
Y ST
EEL
134
TIE
ROD
ALL
OY
STEE
L4
ITEM
N
O.
SHO
RTD
ESC
MA
TERI
AL
QTY
.
35LO
CKN
UT
PLA
TED
STE
EL4
36PI
STO
ND
UC
TILE
IRO
N1
37SP
LIT
CO
LLA
R S
TEEL
438
RET
RIN
G S
TEEL
139
BOLT
STE
EL2
40#
BUSH
PTFE
BRO
NZE
141
* Q
UA
DSE
AL
RUBB
ER1
42*
WEA
R RI
NG
C F
ILLE
D P
TFE
243
*Q
UA
D S
EAL
RUBB
ER1
44*
O-R
ING
BUN
A -
N2
45*
O-R
ING
BUN
A -
N1
46C
OV
ER P
LATE
CA
RBO
N S
TEEL
147
*O
-RIN
GBU
NA
- N
148
AD
APT
OR
CA
RBO
N S
TEEL
149
PIPE
CA
RBO
N S
TEEL
150
END
CA
PC
ARB
ON
STE
EL1
51SP
RIN
G G
UID
ED
UC
TILE
IRO
N1
ITEM
N
O.
SHO
RTD
ESC
MA
TERI
AL
QTY
.
52PU
LL R
OD
ALL
OY
STEE
L1
53BO
LT24
54#
BUSH
PTFE
BRO
NZE
155
SPRI
NG
ALL
OY
STEE
L1
56SP
RIN
GA
LLO
Y ST
EEL
157
BOLT
STE
EL4
58C
OV
ERC
ARB
ON
STE
EL1
59W
ASH
ER S
TEEL
460
*O
-RIN
GBU
NA
- N
161
*O
-RIN
GBU
NA
- N
162
BUTT
ON
PLA
STIC
663
*O
-RIN
GBU
NA
- N
264
NU
T S
TEEL
1265
WA
SHER
STEE
L18
66RE
T RI
NG
STA
INLE
SS S
TEEL
167
BOLT
STE
EL2
68 P
INST
EEL
1
87
65
43
21
ABCD
12
34
56
78
D C B ATM
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
DD
IMEN
SIO
NS
ARE
IN M
ILLI
MET
ERS
AN
D A
RE A
FTER
PLA
TIN
G.
X. .X .XX
1 .75
.25
THIR
D A
NG
LE P
ROJE
CTI
ON
CO
PYRI
GH
T - F
LOW
SERV
E C
ORP
ORA
TIO
NA
LL R
IGH
TS R
ESER
VED
INFO
RMA
TIO
N IN
TH
IS D
OC
UM
ENT
IS C
ON
FID
ENTI
AL
AN
D IS
TH
EEX
CLU
SIV
E PR
OPE
RTY
OF
FLO
WSE
RVE
CO
RPO
RATI
ON
, DEL
IVER
YO
F TH
IS D
OC
UM
ENT
OR
AN
Y C
OPY
TH
EREO
F O
R D
ISC
LOSU
RE O
FSU
CH
INFO
RMA
TIO
N T
O U
NA
UTH
ORI
ZED
PER
SON
S IS
FO
RBID
DEN
.
DIM
ENSI
ON
S W
ITH
T
OLE
RAN
CES
ARE
IDEA
L D
ESIG
N D
IMEN
SIO
NS.
ALL
DIM
ENSI
ON
S A
ND
TO
LERA
NC
ESPE
R A
NSI
Y14
.5M
- 19
82
DO
NO
T SC
ALE
AN
GLE
S 1
/2
DRA
WIN
G N
O.
ENG
BY
CH
K BY
DRW
BY
NEX
T A
SSY
REF
LAYO
UT
R U
NSP
EC R
AD
II
DES
IGN
FIL
E
MA
CH
INE
FIN
ISH
Ra
MA
TERI
AL
SIZE
03/3
0/09
03/3
0/09
D1REV
SCA
LESH
EET
1:20
1 O
F 1
Flo
w C
ont
rol D
ivisi
on
BGL
SITE
EXPL
OD
ED V
IEW
, HD
AC
TUA
TOR,
RG
SER
IES
KNS
SP
2631
89
-
11
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
7 Long Term Storage
Itisrecommendedtotakeprecautionsandcertainmeasureswhenstoringtheactuatorsforextendedperiodsoftime,morethan4monthstotwoyears.
Potentialproblemsandrecommendedprotectionsareasbelow:
6 Torque Shaft
Theoutputshaftisrecommendedtohavetwokeyen-gagements.Shaftmaterialshallbealloysteelwithmini-mum yield strength of 85,000psi. The recommendedhardnessofkeysis25-28HRc.
Recommendedengagementlengthofthekeysisasbe-low(seeFig.:3).
Model Lk (mm) Lo (mm)
RG1 165 180
RG2 195 210
RG3 200 215
RG4 255 270
RG5 300 315
RG6 350 375
RG7 500 515
RG8 585 610
Potential Problem Protection
Waterentryintopneumaticcylinder,degradesthecylinder,par-ticularlyinsalineorcorrosiveenvironment.Temperatureswingscausecondensationinsidecylinders
Storeactuatorinclean,dryandprotectedwarehouse,orun-derventilateddustcover.
Plugallportsafterpurgingwithdryinstrumentairornitro-gen.
Storevertical,toavoidsealset.
Sealcompressionset Cycleactuator5-6timeswithcleandryinstrumentairornitro-gen,every3months.
Degradationofseals inexcessivelycorrosiveorhotenviron-ments
Do not store in locations subjecting the actuator to tem-peraturesinexcessofsealrating.StdsealsareNitrile,maxtemp180degF.
Donotstoreinenvironmentsharmfultoresilientseals.
Physicaldamagetoactuatororaccessories. Storeactuatorassemblyonskid,offthefloor,outofpathways.
Inspecttheprotectionsevery3monthsandrecordinspectionresults.
Fig.: 3 Key Length
LkLo
-
12
User Instructions RG Series Standard Actuator - AXENIM0122-00 12/09
Alldatasubjecttochangewithoutnotice12.2009FlowserveCorporation.FlowserveandKmmeraretrademarksofFlowserveCorporation
Contact:
FlowserveCorporationhasestablishedindustryleadershipinthedesignandmanufactureofitsproducts.WhenproperlyselectedthisFlowserveproductisdesignedtoperformitsintendedfunctionsafelyduringitsusefullife.However,thepurchaseroruserofFlowserveproductsshouldbeawarethatFlowserveproductsmightbeusedinnumerousapplicationsunderawidevarietyofindustrialserviceconditions.AlthoughFlowservecan(andoftendoes)providegeneralguidelines,itcannotprovidespecificdataandwarningsforallpossibleapplications.Thepurchaser/usermustthereforeassumetheultimateresponsibilityforthepropersizingandselection,installation,operation,andmaintenanceofFlowserveproducts.Thepurchaser/usershouldreadandunderstandtheInstallationOperationMaintenance(IOM)instructionsincludedwiththeproduct,andtrainitsemployeesandcontractorsinthesafeuseofFlowserveproductsinconnectionwiththespecificapplication.
Whiletheinformationandspecificationscontainedinthisliteraturearebelievedtobeaccuratetheyaresuppliedforinformativepurposesonlyandshouldnotbeconsideredcertifiedorasaguaranteeofsatisfactoryresultsbyreliancethereon.Nothingcontainedhereinistobeconstruedasawarrantyorguarantee,expressedorimplied,regardinganymatterwithrespecttothisproduct.BecauseFlowserveiscontinuallyimprovingandupgradingitsproductdesign,thespecifications,dimensionsandinformationcontainedhereinaresubjecttochangewithoutnotice.Shouldanyquestionariseconcerningtheseprovisions,thepurchaser/usershouldcontactFlowserveCorporationatanyoneofitsworldwideoperationsoroffices.
Flowserve CorporationFlow Control Division1978ForemanDriveCookeville,Tennessee38501USAPhone:+9314324021Fax:+9314325518www.flowserve.com
Flowserve CorporationFlow Control Division1350NorthMountainSpringsParkwaySpringville,Utah84663-0913USAPhone:+8013733028Fax:+8014892228
Flowserve Pte LtdNo.12TuasAvenue20Singapore638824Phone:+6568798900Fax:+6568624940
Flowserve Flow Control (UK) Ltd.BurrellRoadHaywardsHeathWestSussexUnitedKingdomRH161TLPhone:+441444314400Fax:+441444314401
AutomaxImgroRohr2Limburg,Hessen65549GermanyPhone:+49(0)643196610Fax:+49(0)6431966130
Flowserve Ahaus GmbHvon-Braun-Str.19a48683AhausPhone:+492561686-119Fax:+492561686-109
Flowserve Flow Control GmbHActuators and Automation CenterGermanyRudolfPlankStr.2D-76275EttlingenGermanyPhone+49(0)72431030Fax+49(0)7243103222
Flowserve Flow Control Benelux BVRechtzaad174703RCRoosendaalNBNetherlandsPhone:+31165598800Fax:+31165555670
Flowserve Australia Pty LtdFlowControlDivision14DalmoreDriveScoresby,Victoria3179AustrialiaPhone:+61397593300Fax:+61397593301
Flowserve S.R.LViaPrealpi30CormanoMIItalyI-20032Phone:+3902663251Fax:+39026151863
Flowserve do Brasil LtdaRuaTocantins,128-BairroNovaGertiSoCaetanodoSul,SoPaulo09580-130BrazilPhone:+551142316300Fax:+551142316329-423
Unit 01\02\06\07 9FChinaFortuneTowerNo.1568,CenturyAvenue,PudongShanghaiChina200122Phone:+862138654800Fax:+862150811781
Flowserve CorporationNo.35,BaiyuRoadSuzhouIndustrialParkSuzhou 215021, Jiangsu Province,PRCPhone:+86-512-6288-1688Fax:+86-512-6288-8737
top related