Technical specifications

Features

Power Input voltage: 48VDC

Output voltage: 48VDC (IZI-Link) Output power: Max. 480W Current output: Max. 10A

Control Control in/out: DMX-512 / 1990 galvanically isolated

Dry contact input: 4 galvanically isolated

Miscellaneous Housing: DIN-rail (4 module width)

Input connector: Print connector Screw terminal power connections: Max. 2,5mm² Screw terminal DMX-512: Max. 1,5mm² Screw terminal dry contacts: Max. 1,5mm²

www.tde-lighttech.nl

IZI-Link DMX Interfaceilluminating creativityTDE-lighttech

The IZI-Link DMX interface is needed to setup an IZI-Link system. An IZI-Link system utilises powerline communication to transmit data over a low power voltage network, allowing you to control, monitor and configure each IZI-Link enabled product.This technique eliminates additional control wiring to IZI-Link enabledLED-spots and LED-drivers which make the installation more reliableand easy to install. The IZI-Link system can easily be scaled into a larger network by adding IZI-Link interfaces.

The IZI-Link DMX Interface is controllable through DMX-512 and has 4 additional galvanically isolated contact inputs to override DMX-control for use as emergency contacts or local control switches.

Simple installation2 Wire cable for power and data

High power480 Watt

CommisioningRemote configuring

Emergency contactSystem override contact inputs

Order CodeOrder Code

www.tde-lighttech.nl

illuminating creativityTDE-lighttech

IZI.IF.DMX - IZI-Link DMX inferface; 48VDC; Max 10A; Din railCAB.USB.IZI-LINK - USB to IZI-link programmer cable

90mm

71mm

Dimensions

58mm

MASTER DMX INTERFACE

POWERDMX OK

GND GNDD- D-D+ D+REF REF

DMX512

CONTACT CLOSURE INPUT

Optical isolated Optical isolated

U-in: 48 VDCI-in: 10 A max

POWER INPUT OUTPUT

POWER

V- V+ 2 1 +INPUT OUTPUT

INPUT OUTPUT

PROGRAM SWITCH

Please refer to manual for more information

U-out: 48 VDCI-out: 10 A max

OUTPUTSLAVE

S -

RoHS 75

INDOOR

www.tde-lighttech.com

- 2 3 41

System overview

DMX512 DMX512

CONTACT

IN OUT

48VIN

MASTER DMX INTERFACE

POWERDMX OK

GND GNDD- D-D+ D+REF REF

DMX512

CONTACT CLOSURE INPUT

Optical isolated Optical isolated

U-in: 48 VDCI-in: 10 A max

POWER INPUT OUTPUT

POWER

V- V+ 2 1 +INPUT OUTPUT

INPUT OUTPUT

PROGRAM SWITCH

Please refer to manual for more information

U-out: 48 VDCI-out: 10 A max

OUTPUTSLAVE

S -

RoHS 75

INDOOR

www.tde-lighttech.com

- 2 3 41

LED Driver

LED Driver

A simple overview of an IZI-Link system is shown below. An IZI-Link system is easily scalable, the below shows only a basic system, countless other configurations are possible.

IZI-Link DMX Interface

Use min 90ºC supply conductors when connecting to the IZI-LINK DMX interface

Only use power supplies which can deliver a constant dc-voltage of 48VDC

Wiring

LED indication

www.tde-lighttech.nl

illuminating creativityTDE-lighttech

Wiring diagram

IZI-Link DMX Interface

MASTER DMX INTERFACE

POWERDMX OK

GND GNDD- D-D+ D+REF REF

DMX512

CONTACT CLOSURE INPUT

Optical isolated Optical isolated

U-in: 48 VDCI-in: 10 A max

POWER INPUT OUTPUT

POWER

V- V+ 2 1 +INPUT OUTPUT

INPUT OUTPUT

PROGRAM SWITCH

Please refer to manual for more information

U-out: 48 VDCI-out: 10 A max

OUTPUTSLAVE

S -

RoHS 75

INDOOR

www.tde-lighttech.com

- 2 3 41

DMX Input

1

2

3

0VD-D+

1

2

3

0VD-D+

DMX Output

48VDC+GROUND

+

- IZI-Link output

123

Contact closure

4

-

Status LED Behaviour

Power ok, No data Red On

Green Blink

Power ok, Data reception

Red Off

Green Blink

Protect mode Red Blink

Green -

Identify/Test mode Red Toggle

Green Toggle

Identify mode The Identify mode on the IZI-manager allows identification of each individual fixture/interface.

Test mode When in test mode, the DMX interface sends out value 255 (100%) to all channels on the IZI-Link Master DMX interface.

Protect mode The IZI-link DMX interface will go into protect mode when either, too many load is detected or a power surge has occurred.

illuminating creativityTDE-lighttech

Commisioning

All products need to be powered and connected to an IZI-Link DMX interface, DMX splitter or directly on the DMX input of a fixture in order for any configurations can be made.

The IZI-Link manager and IZI-Link network are connected through the USB to IZI-Link programmer.

The USB to IZI-Link programmer cable needs to be connected to a computer and the DMX512 input of either the IZI-Link Master DMX interface, Splitter or directly on the fixture. When multiple IZI-Link products are connected together make sure to connect to the first IZI-link driver.

MASTER DMX INTERFACE

POWERDMX OK

GND GNDD- D-D+ D+REF REF

DMX512

CONTACT CLOSURE INPUT

Optical isolated Optical isolated

U-in: 48 VDCI-in: 10 A max

POWER INPUT OUTPUT

POWER

V- V+ 2 1 +INPUT OUTPUT

INPUT OUTPUT

PROGRAM SWITCH

Please refer to manual for more information

U-out: 48 VDCI-out: 10 A max

OUTPUTSLAVE

S -

RoHS 75

INDOOR

www.tde-lighttech.com

- 2 3 41

MASTER DMX INTERFACE

POWERDMX OK

GND GNDD- D-D+ D+REF REF

DMX512

CONTACT CLOSURE INPUT

Optical isolated Optical isolated

U-in: 48 VDCI-in: 10 A max

POWER INPUT OUTPUT

POWER

V- V+ 2 1 +INPUT OUTPUT

INPUT OUTPUT

PROGRAM SWITCH

Please refer to manual for more information

U-out: 48 VDCI-out: 10 A max

OUTPUTSLAVE

S -

RoHS 75

INDOOR

www.tde-lighttech.com

- 2 3 41

MASTER DMX INTERFACE

POWERDMX OK

GND GNDD- D-D+ D+REF REF

DMX512

CONTACT CLOSURE INPUT

Optical isolated Optical isolated

U-in: 48 VDCI-in: 10 A max

POWER INPUT OUTPUT

POWER

V- V+ 2 1 +INPUT OUTPUT

INPUT OUTPUT

PROGRAM SWITCH

Please refer to manual for more information

U-out: 48 VDCI-out: 10 A max

OUTPUTSLAVE

S -

RoHS 75

INDOOR

www.tde-lighttech.com

- 2 3 41

MASTER DMX INTERFACE

POWERDMX OK

GND GNDD- D-D+ D+REF REF

DMX512

CONTACT CLOSURE INPUT

Optical isolated Optical isolated

U-in: 48 VDCI-in: 10 A max

POWER INPUT OUTPUT

POWER

V- V+ 2 1 +INPUT OUTPUT

INPUT OUTPUT

PROGRAM SWITCH

Please refer to manual for more information

U-out: 48 VDCI-out: 10 A max

OUTPUTSLAVE

S -

RoHS 75

INDOOR

www.tde-lighttech.com

- 2 3 41

Single IZI-Link driver Multiple IZI-Link drivers

IZI-Link DMX Interface

www.tde-lighttech.nl

top related