Product SpecificationProfile: Exterior:Shadowlineorflat Interior: Shadowline

Embossing: Exterior:Stuccoornon-embossed Interior: Stuccoornon-embossed

Gauge: Exterior:26,24,22ga Interior: 26,24,22ga

Width: 24”,30”,36”,40”,42”

Thickness: 2”,2.5”,3”,4”,5”,6”

Length: 8’-53’

Revealoption: 3/8”toaccommodaterail

Orientation: Verticalorhorizontal

Postfabrication:N/A

R-value: ≈7.2perinchperASTMC518@75˚F ≈8.25perinchperASTMC518@35˚F

Unique KarrierRailKarrierPanelutilizesaKingspandesigneduniquerail.Thisstableandsecurestructuralrailsafelytransmitspositiveloadsfromthemultiplefaçadestothestructuralsupportsbehindtheinsulatedpanels.Similarly,throughfastenerssecuretheexposedrailedge,ensuringthatthesystemsafelyhandlesnegativeloadsaswell.TherailhasbeendevelopedtofullyintegratewithKingspan’sKSseriespaneljoint.Thisrailsystemdoesnotpenetratetheairvaporbarrierandenablesmultipletypesofrainscreenstobeattached.

Installationisquick,simpleandeasy,astherailisinstalledduringnormalpanelinstallation,andissecuredusingstandardpanelfastenersinaonestepprocedure.Thestandardrailconfigurationis16gaugeGalvalume,50KSIsteel.Availableinvariouslengthswitha1,2and3inchbearingsurface.

Customer optionsKingspanoffersafullspectrumofvibrantcolorsforeverycolorscheme.Thehighperformancecoatingsprovidelong-lifeprotection,colorandglossretention.Customcolormatchingisavailabletomeetindividualbuildingdesignsandcreativefreedom.

1

KarrierPanel Data SheetUniversal Barrier Wall Solution

24”-42”

Shadowline

Shadowline

InteriorFace

ExteriorFace

2”-6”

Test Procedure ResultsFire ASTME84 FlameSpread:25orLess/SmokeDeveloped:450orLess

CAN/ULC-S102 FlameSpread:20/SmokeDeveloped:350forpanelwithfacings

CAN/ULC-S127 FlameSpread:<500forfoamcore

NFPA259 Testedforpotentialheatofbuildingmaterials

NFPA268 Passed:Standardtestmethodfordeterminingignitabilityofexteriorwallassemblies usingaradiantheatenergysource

NFPA285 Passed:StandardFireTestMethodforEvaluationofFirePropagationCharacteristics ofExteriorNon-Load-BearingWallAssembliesContainingCombustibleComponents

Structural ASTME72 Vacuumchambertested.Panelload/spananddeflectiontablesareavailable

Thermal ASTMC518Transmission

Air Infiltration ASTME283 0.003CFM/ft2ofPanelAreaat6.24psf

Water ASTME331 Nouncontrolledwaterpenetrationat20psfdifferentialpressure

AAMA501.1 Dynamicwaterpressuretesting–nosignofwaterleakageat15psf

Fatigue Cyclictesttopositiveandnegative Thepanelsexceeded2millionalternatecycleswithoutfailureordamage windloadingto±L/180deflection

Bond Strength ASTMD1623 Panelstestedfortensilebondstrengthofmetaltofoam

Sampleplacedinanautoclavedeviceandpressurizedto2PSIat212°Ffor21/2hrs

Noskindelaminationwithdirectpulloffpressureupto1188psf

2

Performance Testing and ApprovalsKingspaninsulatedpanelsmeetspecificbuildingenvelopeperformancecriteriaandrequirementsstipulatedbyUSandCanadianbuildingcodes.PanelsaretestedinaccordancewithUL,ULCandASTMapprovalstandards,testingmethodsandprocedures.KingspaninsulatedpanelsarelistedbyWarnockHersey.

KarrierPanel Data SheetUniversal Barrier Wall Solution

Kingspan North AmericaDeLand,FL:386-626-6789 Modesto,CA:209-531-9091Caledon,ON:905-951-5600 Langley,BC:604-607-1101www.kingspanpanels.comFortheproductofferinginothermarketspleasecontactyourlocalsalesrepresentativeorvisitwww.kingspanpanels.com

Carehasbeentakentoensurethatthecontentsofthispublicationareaccurate,butKingspanLimitedanditssubsidiarycompaniesdonotacceptresponsibilityforerrorsorforinformationthatisfoundtobemisleading.Suggestionsfor,ordescriptionof,theenduseorapplicationofproductsormethodsofworkingareforinformationonlyandKingspanLimitedanditssubsidiariesacceptnoliabilityinrespectthereof.

Issue4:07/2018

Thermal Performance at 75˚Thickness U-Factor R-Value

2 0.07 14.42.5 0.06 18.03 0.05 21.64 0.03 28.85 0.03 36.06 0.02 43.2

Thermal Performance at 35˚Thickness U-Factor R-Value

2 0.06 162.5 0.05 203 0.04 244 0.03 325 0.03 406 0.02 48