l, 190/350/500 standard entrances 1mod4distribution.com/pdf_files/kawneer standard entrances...l , ,...

Post on 16-Aug-2020

4 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

1190/350/500 STANDARD ENTRANCESAPRIL, 2012

FEATURES

For specific product applications,Consult your Kawneer representative.

Features

• 190narrowstilehas2-1/8"verticalstile,2-1/4"topand3-7/8"bottomrail

• 350mediumstilehas3-1/2"verticalstile,3-1/2"topand6-1/2"bottomrail

• 500widestilehas5"verticalstile,5"topand6-1/2"bottomrail

• Dooris1-3/4"deep

• Dualmomentweldedcornerconstruction

• Singleordoubleacting

• Offsetpivots,butthinges,continuousgearedhingeorcenterpivots

• Surfacemountedorconcealedclosers

• MSlocksorpanichardware

• ArchitectsClassicpush/pulls

• Infillsrangefrom1/4"to1"

• Adjustableastragalutilizingpileweatheringwithpolymericfinatmeetingstiles

• Sealair®bulbpolymericweatherstrippingindoorframes

• Permanodic®anodizedfinishesin7choices

• Paintedfinishesinstandardandcustomchoices

Optional Features

• Numerouspush/pullfinishes

• Paneline®exitdeviceorPaneline® EL exit device

• Widevarietyofbottomrail,crossrailandmuntins

Product Applications

• 190narrowstile-engineeredformoderatetrafficinapplicationssuchasoffices,

storesandapartmentbuildings

• 350mediumstile-providesextrastrengthforschools,institutionsandotherhigh

trafficapplications

• 500widestile-createsamonumentalvisualstatementforbanks,librariesor

buildingsthatexperienceheavytrafficconditions

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

2 190/350/500 STANDARD ENTRANCES APRIL, 2012

BLANK PAGE

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

3190/350/500 STANDARD ENTRANCESAPRIL, 2012

INDEX

LAWSANDBUILDINGANDSAFETYCODESGOVERNINGTHEDESIGNANDUSEOFGLAZEDENTRANCE,WINDOW,ANDCURTAINWALLPRODUCTSVARYWIDELY.KAWNEERDOESNOTCONTROLTHESELECTIONOFPRODUCTCONFIGURATIONS,OPERATINGHARDWARE,ORGLAZINGMATERIALS,ANDASSUMESNORESPONSIBILITYTHEREFOR.

Metric(SI)conversionfiguresareincludedthroughoutthesedetailsforreference.Numbersinparentheses()aremillimetersunlessotherwisenoted.

Thefollowingmetric(SI)unitsarefoundinthesedetails:

m–meter

cm–centimeter

mm–millimeter

s–second

Pa–pascal

MPa–megapascal

Kawneerreservestherighttochangeconfigurationswithoutpriornoticewhendeemednecessaryforproductimprovement.

PICTORIAL VIEW ............................................................................... 5

DOOR TYPES/SECT. DIMENSIONS .................................................. 6

CONSTRUCTION DETAILS ............................................................. 7,8

STOCK ENTRANCE PACKAGES ...................................................... 9

ENTRANCE OFFERINGS ............................................................10, 11

APPLICATION CRITERIA ................................................................ 11

PUSH PULL HARDWARE ................................................................ 12

PANELINE EXIT DEVICE ................................................................. 13

AUTO SHOWROOM DOOR .........................................................14, 15

INTERMEDIATE RAILS .................................................................... 16

INFILL OPTIONS .............................................................................. 16

ACCESSORIES ................................................................................ 16

HANDICAP ACCESSIBLE ITEMS.................................................... 17

BOTTOM RAILS ............................................................................... 18

PANELINE EXIT DEVICE ................................................................. 19

THERMAL CHARTS .................................................................... 20-38

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

4 190/350/500 STANDARD ENTRANCES APRIL, 2012

BLANK PAGE

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

5190/350/500 STANDARD ENTRANCESAPRIL, 2012

PICTORIAL VIEW

#1 MECHANICAL FASTENINGisaccomplished byattachinga5/16"(7.9)thickextrudedaluminum channelcliptotheverticalstilewith1/4"-20heat strengthenedboltsand3/16"thicksteelnutplates forahighstrengthweldingbaseforattachment horizontalmember.

#2 SIGMA* DEEP PENETRATION PLUG WELDS aremadetopandbottomafterthehorizontal isproperlypositionedoverthechannelclipto helpprovidethestrongestdoorcornerjoint currentlyavailable.

#3 SIGMA* FILLET WELDSalongbothtopand bottomwebsoftherailextrusioncompletethe welded corner construction.

* An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA) or also known as Metal Inert Gas (MIG).

WELDED CORNER CONSTRUCTION

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

6

3

2

1

44-5

/16"

(112

5.5)

40-1

3/16

"(1

036.

6)

3

2

1

3

2

1

44-5

/16"

(112

5.5)

41-9

/16"

(104

2.0)

1686

= 4

0" (

1016

)

1786

= 4

0" (

1016

)

8600

= 4

1-11

/16"

(10

58.9

)

8400

= 4

0-13

/16"

(10

36.6

)

2-1/

4"(5

7.2)

17/3

2"(1

3.5)

1-23/32(43.8)

1

"

13-1/

2"(8

8.9)

15"(1

27.0

)

2

3-7/

8"(9

8.4)

2

6-1/

2"(1

65.1

)

2

6-1/

2"(1

65.1

)

31-3/

4"(4

4.5)

3 3

3

2-1/8"(54.0)

3

3-1/2"(88.9)

3

5"(127.0)

190/350/500 STANDARD ENTRANCES APRIL, 2012

DOOR TYPES/SECTION DIMENSIONS

190 NARROW STILE 350 MEDIUM STILE 500 WIDE STILE

SCALE 3" = 1' 0"

STANDARDLOCATIONS

STANDARDLOCATIONS

SINGLE ACTING SINGLE ACTING SINGLE ACTING

DOUBLE ACTING DOUBLE ACTING DOUBLE ACTING

TYPICAL

TY

PIC

AL

TOPATTACHMENT

BOTTOMOFDOOR

OFCYL.

CL

TOPATTACHMENT

BOTTOMOFDOOR

PANICLOCKCYLINDER

CL

STANDARDEXITDEVICE

OF

CR

AS

HB

AR

FO

RK

AW

NE

ER

S

TAN

DA

RD

EX

ITD

EV

ICE

C L

TY

PIC

AL

OF

CR

AS

HB

AR

FO

R

AD

AM

SR

ITE

C L

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

7

1 3

450-019 450-019

2

1 3

450-501 450-501

2

4 5

450-019 450-019

4 5

450-501 450-501

6

7

8 8 8 8

7

1 14 4

66

2 25 53 3

10

9 9

10

190/350/500 STANDARD ENTRANCESAPRIL, 2012

CONSTRUCTION DETAILS

NOTE:1.SERIES190NARROWSTILEDOORSAREDETAILED,MEDIUMSTILE350DOORSANDWIDESTILE500DOORSALSOMAYBEUSED.2.TRIFAB®VG450CENTER,1-3/4"X4-1/2"(44.5X114.3)FRAMINGISDETAILEDWITHTHEDOORSFORREFERENCE.OTHERKAWNEER FRAMINGSERIESORCURTAINWALLSYSTEMSMAYBEUSED.REFERTOTHECATALOGINDEXFORTHEAPPROPRIATEDETAIL SECTION.

SCALE 3" = 1' 0"

450-033INSERT

PAIR OF DOUBLE ACTING DOORS

PAIR OF SINGLE ACTING DOORS

DOUBLE ACTING DOOR SINGLE ACTING DOOR

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

8

069-141069-143 069-143

8

10 7

9

450-012

450-081 450-081

88

069-139 069-139

8 8

10 7

9

450-012

450-502 450-502

069-139 069-139

8 8

10 7

9

041-045041-045

450-079450-079

450-012

190/350/500 STANDARD ENTRANCES APRIL, 2012

CONSTRUCTION DETAILS

SINGLE ACTING DOORS

SCALE 3" = 1' 0"

DOUBLE ACTING DOORS

COC WITH SINGLEACTING OFFSET ARM

OVERHEAD CLOSER FLOOR CLOSER OVERHEAD CLOSER

450-022GLASSSTOPS

450-500TRAY

450-500TRAY

OPTIONALBOTTOMRAILWEATHERING

OPTIONALBOTTOMRAILWEATHERING

OPTIONALBOTTOMRAILWEATHERING

OPTIONALBOTTOMRAILWEATHERING

OPTIONALBOTTOMRAILWEATHERING

OPTIONALBOTTOMRAILWEATHERING

OPTIONALBOTTOMRAILWEATHERING

OVERHEAD CLOSER OVERHEAD CLOSER

450-022GLASSSTOPS

450-022GLASSSTOPS

OVERHEAD CLOSER OVERHEAD CLOSER

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

9

1/4"(6.4)

1/4"(6.4)

3/32"(2.4)

3/32"(2.4)

1/8"(3.2)

1/8"

(3.2

)

1/2"

(12.

7)3/

16"

(4.3

)

1/4"

(6.4

)

1/8"

(3.2

)

190/350/500 STANDARD ENTRANCESAPRIL, 2012

STOCK ENTRANCE PACKAGES

SCALE 3" = 1' 0"

DIMENSIONS ARE NOMINAL

STOCK SIZES (TRIFAB®400&TRIFAB®VG450CENTERFRAMES)WITHOUT TRANSOM Door Opening Dimension Overall Frame Dimension Masonry Opening Dimension 3'-0"x7'-0"(914x2134) 3'-31/2"x7'-13/4"(1003x2178) 3'-4"x7'-2"(1016x2185)3'-6"x7'-0"(1067x2134) 3'-91/2"x7'-13/4"(1156x2178) 3'-10"x7'-2"(1168x2185)6'-0"x7'-0"(1829x2134) 6'-31/2"x7'-13/4"(1918x2178) 6'-4"x7'-2"(1930x2185)

STOCK SIZES (TRIFAB®VG451CENTERFRAMES)WITHOUT TRANSOM Door Opening Dimension Overall Frame Dimension Masonry Opening Dimension 3'-0"x7'-0"(914x2134) 3'-4"x7'-2"(1016x2185) 3'-41/2"x7'-21/4"(1029x2191)3'-6"x7'-0"(1067x2134) 3'-10"x7'-2"(1168x2185) 3'-101/2"x7'-21/4"(1181x2191)6'-0"x7'-0"(1829x2134) 6'-4"x7'-2"(1930x2185) 6'-41/2"x7'-21/4"(1943x2191)

WITH TRANSOMDoor Opening Dimension Overall Frame Dimension Masonry Opening DimensionUnchangedfromabove. Add3'-13/4"(959)toaboveheights. Add3'-13/4"(959)toaboveheights.

WITH TRANSOMDoor Opening Dimension Overall Frame Dimension Masonry Opening DimensionUnchangedfromabove. Add3'-11/2"(953)toaboveheights. Add3'-11/2"(953)toaboveheights.

MASONRYOPENING

OVERALLFRAME

DOOROPENING

MA

SO

NR

YO

PE

NIN

G

OV

ER

ALL

FR

AM

E

DO

OR

OP

EN

ING

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

10 190/350/500 STANDARD ENTRANCES APRIL, 2012

ENTRANCE OFFERINGS

STANDARD

Doors Narrowstile190doorspreparedforattachmenthardware.

Door Sizes Stocksizesshownonpage9.

Glass Stops Beveledglassstopsfor1/4"(6.4)or3/16"(4.0)infill.

Door Frames Trifab® 400 - 1-3/4" x 4" (44.5 x 101.6) for single glazing. Trifab® VG 450Center-1-3/4"x4-1/2"(44.5x114.3)forsingle glazingorTrifab® VG 451Center-2"x4-1/2"(50.8x114.3)for doubleglazing.

Push-Pulls Single Acting: -Architects Classic Hardware "CO-9" Pull and"CP-II"PushBar.

-Architects Classic Hardware "CO-9" Pull and"CP"PushBar.

Double Acting: -ArchitectsClassicHardware"CP"PushBars.

Door Closers Single Acting: -Norton1601adjustableor1601BF adjustablesurfacecloserwithback-check andwithorwithoutadjustablehold-open.

-Standardconcealedoverheadcloserwith singleactingoffsetarm.

Double Acting: Standardconcealedoverheadcloserwith 90degreeor105degreehold-openor withoutholdopen.Forheavytraffic&high windapplications,asupplementaldoorstop isrecommended.

Pivots / Butts Single Acting:Kawneertopandbottomoffsetpivots(or) Kawneertopandbottom41/2"x4"(114.3x101.6)ball bearingbutthingewithnon-removablepin(NRP).

Double Acting:Kawneerbottomcenterpivotsforusewith concealedoverheadcloser.

Intermediate Single Acting:Kawneerintermediateoffsetpivot(or)Pivots/Butts Kawneer4-1/2"x4"(114.3x101.6)ballbearingbutthinge withnon-removablepin(NRP).

Power Single Acting:KawneerELintermediateoffsetpivot(or)Transfers KawneerEL41/2"x4"(114.3x101.6)ballbearingbutthinge withwiretransferorEPT(ElectricPowerTransfer).

Power Supply SP 1000 Power Supply:ForusewithELexitdevices.

Locks - Adams-RiteMS1850Adeadlockwithtwo1-5/32"(29.4)diameterActive Leaf 5pincylinders.

OPTIONAL

Mediumstile350orwidestile500.

Anysizeupto4'-0"x8'-0"(1219x2438).

Squareglassstopsfor3/16"(4.0)or1/4"(6.4)infill.Also1"(25.4)stops.

Any Kawneer framing system suitable for door frames may beselected,butmanufacturedperorder.

Single Acting: -ArchitectsClassicHardware"CO-12" and"CP-II"pushbar.

-ArchitectsClassicHardware"CO-12" and"CP"pushbar.

-ArchitectsClassicHardware "CO-9"/"CO-9"Pulls.

-ArchitectsClassicHardware "CO-12"/"CO-12"Pulls.

Double Acting: -ArchitectsClassicHardware "CO-9"/"CO-9"Pulls.

-ArchitectsClassicHardware "CO-12"/"CO-12"Pulls.

Single Acting: -LCN 4040 surface closer with or without adjustablehold-open.

-LCN2010,2030or5010concealedoverhead closerswithorwithouthold-open.

-LCN1260adjustablesurfacecloser.

-Norton 8100 surface closer with a 50% springpoweradjustment (foropening forces of less than 8 pounds). Closer is available with standard back-checks and with or withoutthehold-openfeature.

-International single act ing concealed overheadcloser.

-DOM/FalconSC60Surfacecloser.

Double Acting: International overhead concealed closer.

Double Acting: Kawneer top center (walking beam) pivot for usewithfloorclosers.

Single Acting: RixsonM-19orIVES#7215-INTintermediate offsetpivot.

PS1, PS5-4, and PS5-6 Power Supplies:ForusewithKawneer 1686ELand1786ELexitdevicesonly.

Adams-Rite#4510latchlock.

Adams-Rite#1850A-500shortthrowdeadlock.

Adams-Rite#1850A-505hookboltlock.

Adams-Rite#4015two-pointLock.

Adams-Rite#4085three-pointLock.

Adams-Rite#4089exitindicator.

Kawneercylinderguard.

Kawneerthumbturn(inlieuofcylinder).

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

11

3.5

3

3 4

2

2

2.5

7

8

9

10

11

5

5

1

1

1.5

A

B

190/350/500 STANDARD ENTRANCESAPRIL, 2012

APPLICATION CRITERIAAsindicatedonPage9,thestandardsizesofswingdoorsare3'-0"x7'-0"(914.4x2133.6)or3'-6"x7'-0"(1067x2134)forsingledoorsand6'-0"x7'-0"(1828.8x2133.6)forpairsofdoors.Whenthesesizesareexceededthefollowingcriteriashouldbeadministered.

1. Largerdoorsshouldnotbesubjecttoheavytrafficor strongprevailingwindconditions.

2. Largerdoorsshoulduseadoorcloserwithagoodback checkaction.

3. Whenadoorexceeds9'-0"(2743.2)inheight,across railorpushbarisrecommendedtoreinforcetheverticalstiles.

4. Whenanoffsethungdoorexceeds7'-6"(2286.0)in height,anintermediatebuttoroffsetpivotshouldbeused.

5. Talldoorsshouldbepreventedfromrackingbyproper utilizationofhardware,includingdoorclosers,doorholders and door stops.

NOTE: SOMEOFTHESECRITERIAAREOFASUBJECTIVE NATURE,CONTACTYOURFACTORYREPRESENTATIVE FORAPPLICATIONASSISTANCE.

ENTRANCE OFFERINGS/APPLICATION CRITERIA

OPTIONAL

Controller® isa3-point lockingsystemconsistingofa twopointlockingdeviceintheinactiveleaf in lieuofflushbolts,workinginconjunction with the MS 1850A deadlock in the active leaf.Thiscombinationprovidesforgreatersecurity thanpossiblewithflushbolts and complies with the life safety considerations of buildingcodeswhichprohibittheuseofflushbolts.

A1/2"x6-3/4"(12.7x171.5)aluminummillfinishthreshold.

BottomDoorSweep

Kawneer 1686 EL Concealed Rod Exit Device electricmodificationisavailable.

Kawneer 1786 EL Rim Exit Device electricmodificationisavailable.

Dor-O-Matic/Falcon EL 1690electricmodificationisalsoavailable.

Dor-O-Matic/Falcon EL 1790electricmodificationisalsoavailable

Paneline® exit deviceisaconcealedrodexitdeviceapplicabletosingleorpairsofdoors. It featuresanactivatingpanelcontainedwithinthedoorcrossrail.

Paneline® ELelectricmodificationisalsoavailable.

Dor-O-Matic/Falcon 1490 and 1990 are concealed rod exit devices withorwithoutarimtypecylinder.

Dor-O-Matic/Falcon 1590 and 2090arerimtypeexitdeviceswithorwithoutarimtypecylinder.Pairsofdoorsrequirearemovablealuminummullion.MullionRM-150withtheDOM/Falcon1590exitdeviceandRM-70withtheDOM/Falcon2090exitdevice.

A = NARROW STILE 190

B = MEDIUM STILE 350 OR WIDE STILE 500

MAXIMUM DOOR HEIGHTFOR PANELINE EL = 8'-0"

FEET

FE

ET

METERS

ME

TE

RS

MAXIMUM SIZE DOOR LEAFSGLAZED WITH 1/4" (6.4) GLASS

Optional Exit Device Pulls:KawneerArchitectsClassic"CO-12"pullhandlewithDor-O-Matic/Falcon1690and1790exitdevices.

Exit Device Pulls: Architects Classic "CO-9" pull handle with Dor-O-Matic/Falcon1690and1790exitdevices.Kawneer"CPN" pullhandlewithPanelineexitdevice. Theoverallheightof the pullmatchestheheightofthePanelinecrossrail.

Locks -Inactive Leaf

OnepairofKawneerflushbolts in the inactive leafofapairofdoors.

STANDARD

A1/2"x4"(12.7x101.6)aluminummillfinishthreshold.

Single Acting: SEALAIR® weathering system in the doorand frame consisting of a dense, bulb polymeric material,which remains resilientand retains itsweatheringabilityundertemperatureextremes.(ThesystemiscompletewithanoptionalEPDMbladegasketsweepstripappliedtothebottomdoorrailwithconcealedfasteners).

Double Acting:Pileclothweatheringinthedoorandframe.

Kawneer 1686 Concealed Rod Exit Devicewithorwithoutamortisedtypecylinder.

Exit Device

Weathering

Thresholds

Kawneer 1786 Rim Exit Device isa rim typeexitdevicewithorwithoutarimtypecylinder.PairsofdoorsrequireaKawneer RM-86removablemullion.

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

12 190/350/500 STANDARD ENTRANCES APRIL, 2012

PANICS AND PULLSEXIT DEVICES

KAWNEER PANELINE® / PANELINE® EL

STYLE"CPN" PULL ONEXTERIOR OF DOOR

SEE PAGE 13 FOR COMPLETE PANELINE® INFORMATION

CONCEALED RODDor-O-Matic/ Falcon 1990

RIM LATCHDor-O-Matic/ Falcon 2090

STYLE "CO-9"PULL

STYLE "CO-12"PULL

CONCEALED RODDor-O-Matic/Falcon 1690

Dor-O-Matic/Falcon EL 1690

RIM LATCHDor-O-Matic/Falcon 1790

Dor-O-Matic/Falcon EL 1790

CONCEALED RODKawneer 1686

Kawneer 1686 EL

RIM LATCHKawneer 1786

Kawneer 1786 EL

PUSH-PULL HARDWARE

ARCHITECTS CLASSIC (PUSH PULL SETS)

SINGLEACTINGDOORSUSEAPULLHANDLEANDPUSHBARASSTANDARDDOUBLEACTINGDOORSUSECPPUSHBARSBACKTOBACKASSTANDARD.

REFERTOHARDWARE SECTION FORCOMPLETEHARDWAREINFORMATION.

*CP-IIPUSHBARISNOTTOBEUSEDFORBACKTOBACKMOUNTINGOND/ADOORS.

STYLE CP-II* PUSH BAR STYLE CP PUSH BARSTYLE CO-9PULL

STYLE CO-12PULL

CO-9/CP-IICO-12 /CP-II

CO-9/CPCO-12/CP

CP-II/CP-II* CP/CP

CO-9/CO-9CO-12/CO-12

ARCHITECTS CLASSIC (COMPONENTS)

EXTERIORVIEWOF190DOOR(350/500SIMILAR) "CPN"PULLANDOPTIONALCYLINDERGUARDSHOWN.

OV

ER

ALL

W/S

TOP

S

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

13

PUSH

PUSH

PUSH

6 1/8"(155.6)

5 7/8"(149.2)

5 7/8"(149.2)

8-1/

4"(2

09.6

)

3'-01/8"(917.8)

1/8"(3.2)

7-1/

8"(1

81.0

)

1-23/32"(43.8)

1-1/8"(27.8)

17/3

2"(1

3.5)

PUSH PUSH

1 2 3*

1 2 3*

190/350/500 STANDARD ENTRANCESAPRIL, 2012

PANELINE® EXIT DEVICE

ACTIVE DOOR SIDELITE *VESTIBULE DOOR(WithoutExitDeviceorLock) CROSSRAIL

WITH EXIT DEVICEAND CPN PULL HANDLE

SIDELITECROSSRAIL

CROSSRAILWITH FIXED

PANEL

TOBOTTOMOFDOOR

SEENOTE

SEENOTE

ThePanelineconcealedrodexitdevicefor190,350and500doorswillaccommodatevariationsinstilewidthanddoorwidthasshowninthefollowingillustrations.SidelitesadjacenttoPanelineequippeddoorsnotrequiringexitdevicesmaybefittedwithfixedpanelsasdetailedbelowtomatchthegeneralappearanceofthePanelinecrossrail.

TheOptionalPaneline®ELdeviceisdesignedforelectrifiedaccesscontrolandiscompatiblewithmostkeypadandcardreadersystems.

SeeHardware SectionforcompletedescriptionofPanelinehardware,includingfinishofunits.

Paneline uses mortise cylinder in lieu of the normal rim-type.Dummy Paneline units are not for use with any type of lock.

INTERIOR ELEVATIONSNOTE:Sidelitesmustbestopglazedaboveandbelowrail.

PANELINE® EL COMPONENTS

POWER TRANSFERINTERMEDIATE BUTT HINGE

POWER TRANSFERINTERMEDIATE OFFSET PIVOT

ELECTRIC POWER TRANSFER(EPT)

SP 1000 POWER SUPPLY

LOCKSTILETRIMFILLERWIDTHVARIESWITHSTILEWIDTH

DOGGINGLOCK(TYPICAL)

190 DOOR

DOOROPENINGWIDTH4'-0"(1219.2)MAX.-2'-99/32"(845.3)MIN.

3'-0"(914.6)ADA MIN.

PIVOTSTILETRIMFILLERWIDTHVARIESWITHDOORWIDTH

350 DOOR

DOOROPENINGWIDTH4'-0"(1219.2)MAX.-2'-1013/32"(873.9)MIN. 3'-0"(914.6)ADA MIN.

1'-115/16"(592.1)ACTIVEPUSHPANEL

FIXEDWIDTH

500 DOOR

DOOROPENINGWIDTH4'-0"(1219.2)MAX.-2'-1129/32"(912.0)MIN. 3'-0"(914.6)ADA MIN.

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

14

10'-3

1/2

" (3

136.

9)

7'-0

" (2

133.

6)

3'-6"x7'-0"

8'-0" (2438.4)

7'-0

" (2

133.

6)

10'-3

1/2

" (3

136.

9)

4'-6"x7'-0" 3'-0"x7'-0" 3'-0"x7'-0" 3'-0"x7'-0"

9'-0" (2734.2)

8'-3 1/2" (2527.3) 9'-3 1/2" (2832.1)

190/350/500 STANDARD ENTRANCES APRIL, 2012

MAXIMUM ALLOWABLE SIZES

•DOOROPENINGWIDTHTO9'-0"(2743.2)

•DOOROPENINGHEIGHTTO8'-0"(2438.4)

•OVERALLFRAMEHEIGHTTO8'-13/4"(2482.9)W/OTRANSOM

•OVERALLFRAMEHEIGHTTO12'-0"(3657.6)WITHTRANSOM

NOTE:1/4"GLAZINGINFILLONLY

SWING TYPE BIFOLD TYPE

AUTO SHOWROOM DOOR

SCALE 3" = 1'-0"

AUTO SHOWROOM PACKAGE

DOORS ..........................190NARROWSTILE,350MEDIUMSTILEAND500WIDESTILEDOORS.

FRAME ...........................TRIFAB®VG450CENTER.

CLOSER .........................NORTON1601ADJUSTABLEOR1601BFADJUSTABLESURFACECLOSER(ACTIVELEAFONLY).

BUTT HINGES ...............ONEPAIR4-1/2"x4"(114.3x101.6)BALLBEARINGBUTTSONACTIVELEAF,ONEANDONEHALFPAIRON INACTIVELEAVESATHINGEJAMB.CONTINUOUSHINGEONINACTIVELEAVES.

LOCKS ...........................ADAMS-RITEMS1850AWITH(2)CYLINDERSONACTIVELEAF.

FLUSHBOLTS ................ONEPAIREDGEMOUNTEDFORINACTIVELEAVES(FACEMOUNTEDON#2INACTIVELEAFOFBIFOLDTYPE).

THRESHOLD .................1/2"x4"(12.7x101.6)ALUMINUM.

RISER BLOCK ...............EXTRUDEDALUMINUMBLOCKAPPLIEDTOBOTTOMRAILOFEACHINACTIVELEAF.

OPTIONAL CASTER ..... INLIEUOFRISERBLOCK,FACEAPPLIEDCASTERTOLEADINGSTILEOFINACTIVELEAF.

FRAMEWIDTH FRAMEWIDTH

DOOROPENING DOOROPENING

DO

OR

OP

EN

ING

DO

OR

OP

EN

ING

FR

AM

EH

EIG

HT

FR

AM

EH

EIG

HT

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

15

450-501 450-501

450-501 450-501

450-501

190/350/500 STANDARD ENTRANCESAPRIL, 2012

AUTO SHOWROOM DOOR

SCALE 3" = 1' 0"

OVERALLFRAME

DOOROPENING

SWING TYPE

OVERALLFRAME

DOOROPENING

BIFOLD TYPE

OPTIONALCONTINUOUS HINGE

JAMB

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

16

1/2"(12.7)

1"(2

5.4)

1/2"(12.7) 11

/16"

(42.

9)

1"(25.4)

1-3/

8"(3

4.9)

200-054

200-039 with 249-235

10"

(254

)

069-139

069-143

039-345

*

069-141

190/350/500 STANDARD ENTRANCES APRIL, 2012

THRESHOLDS

INFILL OPTIONS

ACCESSORY ITEMS

APPLICATION

FORSINGLEACTINGDOOR

FORCENTERHUNGCONCEALEDCLOSER

*SOME BUILDING CODES LIMIT THRESHOLD HEIGHT TO 1/2” (12.7) MAX.

APPLIEDSTOPFORSINGLEACTINGDOOR

OPTIONALBOTTOM RAILWEATHERING

069-177APPLIED

DOORSTOP

038-365FINGER

PROTECTOR

069-154APPLIED

DOORSTOP

HORIZONTAL / VERTICAL INTERMEDIATE RAILS

SCALE 3" = 1' 0"

INTERMEDIATE RAILS, INFILL OPTIONS AND ACCESSORIES

3/16" (4.3) & 1/4" (6.4) INFILL

OPTIONAL STANDARD

5/16" (7.9) & 3/8" (9.5) 7/16" (11.1) & 1/2" (12.7) 9/16" (14.3) & 5/8" (15.9) 11/16" (17.5) & 3/4" (19.0) 15/16" (23.8) & 1" (25.4)

BEVEL GLASS STOPS

SQUARE GLASS STOPS

FORCENTERHUNGFLOORCLOSERS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

17

10"

(254

.0)

12"

(304

.8)

16"

(406

.4)

OR

7 1/

2"(1

84.2

)

10"

(254

.0)12

"(3

04.8

)

190/350/500 STANDARD ENTRANCESAPRIL, 2012

HANDICAP ACCESSIBLE ITEMS

Note:Theword"Pull"andthesymbolofaccessanodizedontheexteriorsurfaceoftheoptionalcrossrailarestandard-blackonclearrail,clearondarkbronzeorblackrail.Anodizedlettersonpushbaraccentareclearonblack.Lettersandsymbolsonplasticpushshieldareengravedandfilledwithwhiteepoxyenamel.

Description ArchitectsClassicCO-12Pull BF3PushShieldwithsymbol

Application Doorwithorwithoutexit device

Doorcrossrail(omitw/exitdevice)

Length/Size 12"OCPullattachment 15-7/8"x7-7/8"(403.2x200.0)1/8"(3.2)Thick

HeightLocation 44-5/16"fromTopMountingHoletoBtm.ofDoor

TotalProjection 3-1/4"(82.6)Projection 1/8"(3.2)

SeeHardwareSectionA8Material/Finish BlackPlastic

PebbleFinish

PUSH-PULLSSTYLE

BOTTOM RAILSStandardrailheightsshownmaybeusedon190,350and500doors.Customheightsavailable.

SCALE 3" = 1'-0"

CROSS RAIL (Optional)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

18

3-7/

8"(9

8.5)

6-1/

2"(1

65.1

)

6-1/

2"(1

65.1

)

190

350 500

190/350/500 STANDARD ENTRANCES APRIL, 2012

SCALE 3" = 1' 0"

BOTTOM RAILS

NOTE:See Page 16foravailableIntermediateHorizontalMembers.

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

19

21 or 3* 1 or 3*

PUSH PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

8-1/

4"(2

09.6

)

3'-01/8"(917.8)

1/8"(3.2)

7-1/

8"(1

81.0

)

1-23/32"(43.8)

1-1/8"(27.8)

17/3

2"(1

3.5)

1 2 3*

190/350/500 STANDARD ENTRANCESAPRIL, 2012

PANELINE® EXIT DEVICE

SidelitesadjacenttoPanelineequippeddoorsnotrequiringexitdevicesmaybefittedwithfixedpanelsasdetailedbelowtomatchthegeneralappearanceofthePanelinecrossrail.

SeeHardware SectionforcompletedescriptionofPanelinehardware,includingfinishofunits.

Paneline uses mortise cylinder in lieu of the normal rim-type.Dummy Paneline units should not use any type of lock.

INTERIOR ELEVATIONNOTE:Sidelitesmustbestopglazedaboveandbelowrail.

* ALTERNATE CROSSRAIL FOR VESTIBULE DOORS (Without Exit Device or Lock)

CROSS RAILWITH EXIT DEVICE

AND PULL

SIDELITECROSS RAIL

CROSS RAILWITH

FIXED PANEL

TOBTMOFDOOR

(FIXEDLOCATION)

SEENOTE

SEENOTE

INACTIVE DOOR ACTIVE DOOR SIDELITE

EXTERIOR VIEW OF 190 DOOR (350-500 SIMILAR)WITH "CPN" PULL AND STANDARD CYLINDER GUARD

SHOWN

STYLE"CPN" PULL ONEXTERIOR OF DOOR

LOCKSTILETRIMFILLERWIDTHVARIESWITHSTILEWIDTH

DOGGINGLOCK(TYPICAL)

190 DOOR

DOOROPENINGWIDTH8'-0"(2438.4)MAX.-5'-71/4""(1708.2)MIN.

6'-0"(1828.8)ADA MIN.

PIVOTSTILETRIMFILLERWIDTHVARIESWITHDOORWIDTH

350 DOOR

DOOROPENINGWIDTH8'-0"(2438.4)MAX.-5'-95/16"(1761.0)MIN. 6'-0"(1828.8)ADA MIN.

1'-57/8"(454.0)

ACTIVEPUSHPANELFIXEDWIDTH

(FOR6'-0"WIDTH)

500 DOOR

DOOROPENINGWIDTH8'-0"(2438.4)MAX.-6'-0"(1828.8)MIN.

6'-0"(1828.8)ADA MIN.

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

20

0.49

66%

0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20

0.70

0.80

0.60

0.50

0.40

0.30

0.2085 80 75 70 65 60

0.75

0.65

0.55

0.45

0.35

0.25

(2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14)

0.90

0.85

7'-2

"(2

184.

4)3'-4"

(1016.0)

30.125"(765.2)

75.7

5"(1

924.

1)

190/350/500 STANDARD ENTRANCES APRIL, 2012

THERMAL CHARTS

Project Specific U-Factor Example Calculation

ExampleGlassU-Factor =0.28Btu/hr•ft2•°F

TotalDaylightOpening =30.125"x75.75"=15.85ft2

TotalProjectedArea =3'-4"x7'-2"=23.9ft2

PercentofGlass =(TotalDaylightOpening÷TotalProjectedArea)100 =(15.85÷23.9)100=66%

System U-factor vs Percent of Glass Area

EXAMPLE

NOT FOR DESIGN

COGU-factor

Percent of Glass Area

Basedon66%glassandcenterofglass(COG)U-factorof0.28SystemU-factorisequalto0.49Btu/hr•ft2•°F

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

(DLO)

(DLO

)

(F.W.)(F

.H.)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

21

0.48(2.73)0.46(2.61)

0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

190/350/500 STANDARD ENTRANCESAPRIL, 2012

190 (SINGLE DOOR)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

22 190/350/500 STANDARD ENTRANCES APRIL, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

190 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

23

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.78

0.77

0.76

0.75

0.74

0.73

0.72

0.71

0.70

0.69

0.68

0.67

0.66

0.65

0.64

0.63

0.61

0.60

0.59

0.58

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.44

0.41

0.38

0.35

0.32

0.29

0.26

0.23

0.21

0.18

0.15

0.12

0.09

0.06

0.03

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.48

0.45

0.42

0.39

0.36

0.33

0.30

0.27

0.24

0.21

0.18

0.15

0.13

0.10

0.07

190/350/500 STANDARD ENTRANCESAPRIL, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolationispermitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof960mmwideby 2090mmhigh(37-3/4"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

190 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

24

0.47(2.67)0.46(2.61)

0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

190/350/500 STANDARD ENTRANCES APRIL, 2012

190 (PAIR OF DOORS)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

25190/350/500 STANDARD ENTRANCESAPRIL, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

190 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

26

0.47

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.73

0.72

0.71

0.70

0.69

0.68

0.67

0.66

0.64

0.63

0.62

0.61

0.60

0.59

0.58

0.56

0.55

0.54

0.53

0.52

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.47

0.44

0.41

0.38

0.35

0.31

0.28

0.25

0.22

0.19

0.16

0.13

0.09

0.06

0.03

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.50

0.47

0.44

0.41

0.38

0.35

0.31

0.28

0.25

0.22

0.19

0.16

0.13

0.09

0.06

190/350/500 STANDARD ENTRANCES APRIL, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolationispermitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof1920mmwideby 2090mmhigh(75-1/2"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

190 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

27

0.48(2.73)0.46(2.61)

0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

190/350/500 STANDARD ENTRANCESAPRIL, 2012

350 (SINGLE DOOR)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

28 190/350/500 STANDARD ENTRANCES APRIL, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

350 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

29

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.83

0.82

0.81

0.81

0.80

0.79

0.78

0.77

0.76

0.75

0.74

0.73

0.72

0.71

0.70

0.69

0.68

0.68

0.67

0.66

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.39

0.36

0.34

0.31

0.29

0.26

0.23

0.21

0.18

0.16

0.13

0.10

0.08

0.05

0.03

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.43

0.41

0.38

0.36

0.33

0.30

0.28

0.25

0.23

0.20

0.17

0.15

0.12

0.10

0.07

190/350/500 STANDARD ENTRANCESAPRIL, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolationispermitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof960mmwideby 2090mmhigh(37-3/4"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

350 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

30

0.47(2.67)0.46(2.61)

0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

190/350/500 STANDARD ENTRANCES APRIL, 2012

350 (PAIR OF DOORS)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

31190/350/500 STANDARD ENTRANCESAPRIL, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

350 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

32

0.47

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.79

0.78

0.77

0.76

0.75

0.74

0.73

0.72

0.71

0.70

0.69

0.68

0.67

0.66

0.65

0.64

0.63

0.62

0.61

0.60

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.42

0.39

0.36

0.34

0.31

0.28

0.25

0.22

0.20

0.17

0.14

0.11

0.08

0.06

0.03

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.46

0.43

0.40

0.37

0.35

0.32

0.29

0.26

0.23

0.21

0.18

0.15

0.12

0.09

0.07

190/350/500 STANDARD ENTRANCES APRIL, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolationispermitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof1920mmwideby 2090mmhigh(75-1/2"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

350 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

33

0.48(2.73)0.46(2.61)0.44(2.50)0.42(2.39)

0.40(2.27)0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

190/350/500 STANDARD ENTRANCESAPRIL, 2012

500 (SINGLE DOOR)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

34 190/350/500 STANDARD ENTRANCES APRIL, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

500 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

35

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.87

0.86

0.85

0.84

0.84

0.83

0.82

0.81

0.81

0.80

0.79

0.78

0.77

0.77

0.76

0.75

0.74

0.73

0.73

0.72

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.33

0.31

0.29

0.27

0.25

0.22

0.20

0.18

0.16

0.13

0.11

0.09

0.07

0.04

0.02

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.38

0.36

0.34

0.32

0.29

0.27

0.25

0.23

0.21

0.18

0.16

0.14

0.12

0.09

0.07

190/350/500 STANDARD ENTRANCESAPRIL, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolationispermitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof960mmwideby 2090mmhigh(37-3/4"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

500 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

36

0.47(2.67)0.46(2.61)0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

190/350/500 STANDARD ENTRANCES APRIL, 2012

500 (PAIR OF DOORS)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

37190/350/500 STANDARD ENTRANCESAPRIL, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

500 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-43

38

0.47

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.82

0.82

0.81

0.80

0.79

0.78

0.77

0.77

0.76

0.75

0.74

0.73

0.72

0.71

0.70

0.70

0.69

0.68

0.67

0.66

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.36

0.34

0.32

0.29

0.27

0.24

0.22

0.19

0.17

0.15

0.12

0.10

0.07

0.05

0.02

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.41

0.38

0.36

0.34

0.31

0.29

0.26

0.24

0.21

0.19

0.17

0.14

0.12

0.09

0.07

190/350/500 STANDARD ENTRANCES APRIL, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolationispermitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof1920mmwideby 2090mmhigh(75-1/2"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

500 (PAIR OF DOORS)

top related