led t8 basic - 浙江炬星照明有限公司 · led t8 basic tri-proof tube product information...
Post on 21-Jun-2020
6 Views
Preview:
TRANSCRIPT
Zhejiang Gesung Lighting Co.,Ltd. For more information, visit gesung.com or call +86 -(0)577 8856 9177. E-mail led@gesung.com No.8 Zhong Rd Juguang Industrial Wenzhou,China
Copyright 2017 Gesung Lighting. All rights reserved. Specifications subject to change without notice
- 1 -
DATA SHEET
LED T8 Basic Tri-proof Tube
Product information
The Gesung Trip T8 reliable and affordable energy saving
alternatives to standard Fluorescent T8 lamps.Available in 60cm,
120cm and 150cm lengths, Geusng LED T8s can be quickly fitted
as a replacement into lumenaires operating on
electro-magnetic control gear or on electronic gear with a
simple re-wire (for further details see installation guide).
Applications
Features
• Rugged thermoplastic ,6063 aluminum
• Shatterproof – Provides ultimate level of safety &
protection against accidental breakage
•• Up to 80% energy sav ings vs. fluorescent
• Choice of 3000K, 4500K, or 6000K CCT
• Av ailable in both standard and high output lumens
• Solid state replacement for 2’ and 4’ T8 G13
base linear fluorescent
• Operates on 120-277V – No ballast required
• Suitable for use in totally enclosed fixtures
• Env ironmentally friendly: contains no glass,
mercury or lead.
Dimensions [mm]
Maximum
ov erall
length [mm]
2 ft 3 ft 4 ft
A 600 900 1200
B 75 75 75
C 22 22 22
D 23.5 23.5 23.5
Weight [g] <200 <260 <390
Zhejiang Gesung Lighting Co.,Ltd. For more information, visit gesung.com or call +86 -(0)577 8856 9177. E-mail led@gesung.com No.8 Zhong Rd Juguang Industrial Wenzhou,China
Copyright 2017 Gesung Lighting. All rights reserved. Specifications subject to change without notice
- 2 -
Specification summary
* OEM Customization parameter
Specifications
Nominal Voltage 100-240V/185-245V/120V
Operating frequency 50 – 60Hz
Power factor 0.6/0.9
Ambient temperature range -20°C – +40°C
Starting time < 0,5 s
Lumen maintenance at B50 70%
Beam angle 270-320°
Dimmable No
Operation and maintenance
Store and use the lamps the same way as standard
fluorescent lamps.
• Lamps should be kept free from contamination.
• Switch off mains supply before installing/removing
lamp.
• Good condition of the lamp-holder contacts is important
to ensure proper operation of lamp.
• For magnetic gear system ensure existing fluorescent
starter is replaced with LED T8 starter (included in each
pack)
• For direct wire please check the provided installation
instructions
• Use in fully enclosed fixtures may affect life
performance.
• Not for use in emergency lighting circuits
Item Leng
th
Lm/w
*
W
*
CCT CRI
*
Beam * Appea
rance
*
Envelop
e
CE* RoHs
*
IP LED
Type
Life
GET8-TP60-18W
3000K
600m
m
70/80/
90
18
W
3000
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP60-18W
4500K
600m
m
70/80/
90
18
W
4500
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP60-18W
6000K
600m
m
70/80/
90
18
W
6000
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP90-27W
3000K
1200
mm
70/80/
90
27
W
3000
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP90-27W
4500K
1200
mm
70/80/
90
27
W
4500
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP90-27W
6000K
1200
mm
70/80/
90
27
W
6000
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP120-36
W 3000K
1500
mm
70/80/
90
36
W
3000
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP120-36
W 4500K
1500
mm
70/80/
90
36
W
4500
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
GET8-TP120-36
W 6000K
1500
mm
70/80/
90
36
W
6000
K
70/80/9
0
270°-320
°
Froste
d
PC+Alu
minum
✓ ✓ 20 SM D
2835
30,00
0
Zhejiang Gesung Lighting Co.,Ltd. For more information, visit gesung.com or call +86 -(0)577 8856 9177. E-mail led@gesung.com No.8 Zhong Rd Juguang Industrial Wenzhou,China
Copyright 2017 Gesung Lighting. All rights reserved. Specifications subject to change without notice
3
Light Distribution Diagram GET8-TP60-9W ( 6K 220VAC) GET8-TP90-18W (6K 220VAC) GET8-TP120-36W ( 6K 220VAC)
Light AAI Figure GET8-TP60-9W ( 6K 220VAC) GET8-TP90-18W (6K 220VAC) GET8-TP120-36W ( 6K 220VAC)
Wiring Diagram
Always turn off the electricity supply before installation.
1. When install or replace, please shut off power supply of tubes.
2. If the installation or failure occurs, please professional personnel to install or uninstall and maintenance.
3. Please do not open the product itself.
4. Please don't use the Tube in acid mist gas place.
5. Please follow the installation diagram instructions.
6. The plug into the lamp socket with AC 220V/AC 85V-265V(According to local custom v oltage requirements)
Zhejiang Gesung Lighting Co.,Ltd. For more information, visit gesung.com or call +86-(0)577 8856 9177. E-mail led@gesung.com No.8 Zhong Rd Juguang Industrial Wenzhou,China
Copyright 2017 Gesung Lighting. All rights reserved. Specifications subject to change without notice
- 4 -
Packaging
Inner Box +Carton
Products 9W 18W 24W
Length A (mm) 589 1198 1498
Qty/CTN 20pcs 20pcs 20pcs
CTN Size 640*270*165 940*270*165 1245*270*165
G.W/CTN(kg) 3.54 5.14 6.46
top related