lux shower channel - tile insert fixed length · kado lux shower channel - tile insert fixed length...
Post on 07-Jun-2018
220 Views
Preview:
TRANSCRIPT
KADO
CLEANING RECOMMENDATIONS
To see the complete KADO range go to www.reece.com.au/bathrooms
LUX SHOWER CHANNEL - TILE INSERT FIXED LENGTH
We recommend the use of soapy water or approved cleaners.
This product should not be cleaned with abrasive materials.
Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions.
Dimensions are nominal measurements only.
SPECIFICATIONSRecommended use Domestic, Hotel and Commercial
Length 900mm
1000mm
1200mm
1500mm
Material 316 marine grade stainless steel
Colour availability Satin stainless
Waste DN80
Features Fully finished welded ends, centre outlet 3mm thick heavy wall tile insert tray. ‘One drain for whole bathroom’ compliant DN80 outlet, easy clean grate.
Compliance WaterMark 21254, heel safe, child safe
Sustainability Global GreenTag, Level A Gold
ATS 5200.040:2005
21254
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer distributor takes no responsibility for printing errors.
Tech Page Version 4
Fixed lengths of 900, 1000, 1200, 1500
90
90
33
30 76.2 (DN80)
13
page 1 of 2
KADOLUX SHOWER CHANNEL - TILE INSERT FIXED LENGTH
• Ensure the channel is completely level• Cut the tile 1mm narrower than the tile insert tray, i.e. 65mm.• Ensure the inserted tile joints line up with the floor tile joints• Using tile adheasive set the tile into the tile insert tray.
Installation and preparation of the shower or bathroom floor should be as per AS3500 and AS3740.
There are variations of acceptable installations in different jurisdictions around Australia. Check with your local regulator if you are unsure of your local requirements.Only WaterMark certified products are allowed to be installed. Products without WaterMark certification will be deemed non compliant and removal will be required. This will likely be expensive and time consuming.
INSTALLATION
NOTE, this method require the channel system to be ABOVE and SEPARATE from the waterproofing
page 2 of 2
Don’t risk it, use a licensed plumber.™