manual for storage tent arched plus 9,15x20x4,5m pvc · 9.15x20x2x4.5m arched plus part number...

Post on 12-Jun-2020

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

30-11-2017

forStorage Tent Arched Plus

9,15x20x4,5m PVC

Manual

Safety Advice AttentionIn some countries approval is needed to set up a marquee/tent larger than 75 m2. It is your responsibility to comply with local rules and regulations and to ensure that the marquee/tent is assembled correctly.

In case of bad weather conditions, it is your responsibility to ensure the marquee/tent is safely secured and that the marquee/tent does not cause damage to others.

close to the tent.

The marquee/tent must be safely secured. We recommend you secure your marquee/tent with straps and pegs as soon as it is assembled.

Make sure to check if the marquee/tent is covered by your home contents insurance.

Marquees/tents must be evacuated under extreme weather conditions.

In the event of snow always remove snow from the roof of the marquee/tent regularly to prevent snow from building on the roof as heavy snow can cause the marquee/tent to collapse.

In the event of rain there is a risk of rain puddles building up on top of the roof of the marquee/tent. Heavy rain puddles can cause the roof to collapse. It is your responsibility to ensure rain puddles do not build up. As a precaution, make sure the roof of the marquee/tent is stretched out properly and adequately over the side frames of the marquee/tent and remove rain water regularly.

Do not unpack or repack your marquee/tent in freezing temperatures. In case of temperatures below zero always unpack and repack your marquee/tent indoors to avoid the risk of cracking parts.

The marquee/tent must be totally dry before you repack and store it to avoid mildew.

Warranty InformationPlease visit dancovershop.com for information on warranty.

Maintenance: You must regularly check and retighten all assembly points of your storage shelter or garage tent. It is especially important to retighten the roof cover 1 month after having erected your shelter or tent. The roof cover of your shelter or tent must always be tensioned to withstand wind and weather.

Please always check our website for the latest safety advice and manual l.

This structure is not tested for snow and wind loads. We always recommend that you remove snow from the roof. This is a none-permanent structure.

Assembly Illustration

For “user friendly” assembly we have identified each individual component

with our partcode number as indicated in the part list.

Please refer to the part code number and drawings to ensure problem free

assembly.

30-11-2017

9.15x20x2x4.5m ARCHED PLUS

Partnumber Description

Top roof curved tube

Roof curved tube

Sidewall tube

Sidewall tube at front and rear

Tube at front and rear

Roof purlin and horizontal tube

Side beam for front and rear

Female Tensioning tube for lower roof cover

Female Door dropping tube at the bottom

Male Door dropping tube at the bottom

Stake peg

Bolt M10x110

Bolt M10x90

Standing support tube

Tube slip for standing support tube

and back panel

Lower standing leg in front and rear panel

Upper standing leg in front and rear panel

Qty. Illustration Box

1

38

4

38

4

100

2

2

4

38

4

4

4

2

4

134

108

359

48

20

2

2

2

2

2A

3

3A

4

5L

5R

6

7

8

9

10

11

12

16

17

18

13

13A

14A

15A

15

A-B

A-C

B

B-C

B

A

A

A

A

A

11A 2 A

Bottom tensioning tube for front and Arear cover

A

14 Male Tensioning tube for lower roof cover

A

A

A

A

B

B

B

B-C

B

B-C

B

B

Male beam for front and rear with 1 wheel pulley

Female beam for front and rearwith 2 wheels pulley

21

Sidewall tube 423B B-C

9.15x20x2x4.5m ARCHED PLUS

Qty. BoxIllustration

1

2

1Roll

42

12

4

22

23

24

31

26

27

A

A

B

B

B

B

B

21 42

Partnumber Description

Roof cover

21A Bolt M10x12 for Tie down rathcet 84 B

Front and back cover

Lace rope for roof cover, front cover and rear cover

Nylon tensioning band for tie down ratchet

Plastic cap for tensioning tube

Plastic cap for part 15

29 Hexagonal Washer M10 B915

30 Hexagonal Nut M10 507 B

Bolt M10x100

Bolt M10x30

Bolt M10x75

16

20

4

18A

19

20

B

B

B

Tie down ratchet ( )

30-11-2017

Frame sketch9,15x20x3,5x4,5

10

18

Figure 2

Position of base flanges

1

2/2A

3/3A

3B

12A

3A

3B

9

8

10

11 11A

65L5R

Frame installation for middle and back panel

Frame installation for front panel

12A

3A

3B

4

Figure 8

Figure 9

As per Figure ll, please pull the roof cover over the frame evenly.

Remark Page:

Assembly Steps

2. Each group of sidewall is made up of Curved Roof Tubes, Sidewall Tubes(Vertical Tubes).

3. Put the left sidewall into the receiving tube on left Base Flange, and push the right sidewallto the receiving tube on right Base Flange. Because it needs tension for every group of sidewall,

'c' show.

all groups of sidewall and Horizontal tubes.

Tensioning Tubes through the pockets at the bottom of both sides of roof cover. Then pull the TieDown Ratchets forth and back to tension the roof cover. Then plz fasten the end of roofcover by ropes

the door installation by yourself.

The receiving tube onleft Base Flange

Figure a.First assemble every groupof sidewall

Figure d.Installation of Horizontal Tubes

The second group of sidewall

The horizontal tube

Figue b.Then put the left sidewall intothe receiving tube on left Base Flange

Figure c.Thirdly, push hard the right sidewall to the receiving tube on right Base Flange

The receiving tube onleft Base Flange

Contact information

Head office:Dancover A/SNordre Strandvej 119 G3150 HellebækDenmark

For more informationplease visit:www.dancovershop.com

National contact

Denmark: 70 26 76 20denmark@dancover.com

UK: 020 8099 7570uk@dancover.com

Spain: 911 436 828espana@dancover.com

Italy: 02 479 21 198italia@dancover.com

Germany: 041 0266 7040germany@dancover.com

Switzerland: 0840 000125schweiz@dancover.com

France: 0975 181 800france@dancover.com

Austria: 0662 626935austria@dancover.com

Sweden: 040 233 262sverige@dancover.com

Finland: 0 931 581 720suomi@dancover.com

Nederland: 0 858 880 524nederland@dancover.com

Poland: 22 300 8602polska@dancover.com

Ireland: 0 151 33 003ireland@dancover.com

Luxembourg: +49 041 0266 7040luxembourg@dancover.com

Portugal: 308 800 899portugal@dancover.com

Belgium: 0 28 08 08 09belgique@dancover.com

Norway: 231 00 690norge@dancover.com

top related