Mitsubishi Graphic Operation TerminalS i m p l y t h e b e s t
GR
AP
HI
C
OP
ER
AT
IO
N
TE
RM
IN
AL
GO
T1
00
0
Mitsubishi Electric Corporation Nagoya Works and Himeji Works are factories certified for ISO14001 (standards for environmental manage-ment systems) and ISO9001 (standards for quality assurance man-agement systems).
http://MitsubishiElectric.co.jp/melfansweb/english/
It's not a mere display. It's a GOT.
It's what we do. Coming up with answers. Breaking new ground.And now it's here-the GOT1000-reflecting the next generation's vision.How far can a display evolve when functions are inspired by the voices of actual users, rather than a race for that "new look"?
To answer this question, Mitsubishi drew on its technology and experience cultivated at actual FA worksites, and the resulting GOT1000 sets the standard for the next generation.
In addition to raising the level of display basics such as response, display, and connectivity, the GOT1000 is packed with ideas and functions designed to improve productivity and workability.
In short, the GOT1000 is about usability, and creating new value.
The GOT1000 not only gives customers improved connectivity to PLCs and a host of other FA devices, it provides a powerful competitive edge in the global market as well.
T o w a r d a u n i q u e G O T b r a n d
Its beauty alone, its functionality alone, takes the GOT1000 beyond a mere "display". But what really sets it apart is the usability that was inspired by voices from actual worksites.
Concept
Lineup
Features
Connectable model list
Connection configuration
Bus connection
Specification
External dimensions
Function list for each model
Notes for use
List of products
2
4
819202226
28
32
38
48
50
52
54
56
For designersFor operatorsFor intial startup & adjustment operatorsFor maintenance personnelHandy GOT
I N D E X
S i m p l y t h e b e s t
The needs expressed by users will continue to be a central part of the GOT series evolution to the next-generation display. Mitsubishi Electric's aims are summed up by the slogan, "Simply the best!".
8.4''Type
Resolution: VGA 640 x 480Display colors: 16 colors
TFTGT1562-VNBA (AC type)GT1562-VNBD (DC type)
10.4''Type
Resolution: VGA 640 x 480Display colors: 256 colors
TFTGT1575-VNBA (AC type)GT1575-VNBD (DC type)
8.4''Type
Resolution: VGA 640 x 480Display colors: 256 colors/65536 colors*1
TFT (High-brightness, wide viewing angle)GT1565-VTBA (AC type)GT1565-VTBD (DC type)
10.4''Type
Resolution: VGA 640 x 480Display colors: 256 colors/65536 colors*1
TFT (High-brightness, wide viewing angle)GT1575-VTBA (AC type)GT1575-VTBD (DC type)
10.4''Type
Resolution: SVGA 800 x 600Display colors: 256 colors/65536 colors*1
TFT (High-brightness, wide viewing angle)GT1575-STBA (AC type)GT1575-STBD (DC type)
12.1''Type
Resolution: SVGA 800 x 600Display colors: 256 colors/65536 colors*1
TFT (High-brightness, wide viewing angle)GT1585-STBA (AC type)GT1585-STBD (DC type)Resolution: XGA 1024 x 768
Display colors: 256 colors/65536 colors*1
TFT (High-brightness, wide viewing angle)GT1595-XTBA (AC type)
15''Type
USB interfaceStandard item & front-mounted
An innovative and highly perfected platform sets the GOT1000 Series in a class all by itself
Throughout our pursuit to deliver a solution that meets the needs of the industry, we developed an innovative platform based on performance, technology and design - the GOT1000 Series. This development concept is shared across the "Basic" (GT11 Series) and "Advanced" models (GT15 Series) to offer a wide range of flexible panel mount and pendant style solutions.
GOT1000 common features
Drawing, computing, communicationA triad of high-speed response
Beautiful and expressive screen
mDrawing...Equipped with a high-speed drawing chip (GT15 only)mComputing...Offers high-speed computing performancemCommunication...Bus connection (GT15 only) and RS-232 communication (max. 115.2kbps)
mUp to 20 times faster data transmission than previous modelsmFront-mounted USB interface allows fast data exchange
m65536 Full color (GT15)mMonochrome 16 gray scales (GT11)mGreatly increased memory capacity
Full-spec models accommodate a wide range of applications in stand-alone or network environmentsGT15
10.4''Type
Resolution: VGA 640 x 480Display colors: 16 colors
TFTGT1572-VNBA (AC type)GT1572-VNBD (DC type)
Features
Standard interface, standard memory size
Connection format*3
65536 colors 256 colors Human sensor
Multi channel Transparent System monitor
Intelligent unit monitor Q motion monitor Servo
amplifier monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Ethernetdownload
A/FX list editor
Network monitor
Memory 9MB
MELSECNET/10
Gateway
Ladder monitor
CNC monitor CNC monitor
CC-Link
*2
Features
Standard interface, standard memory size
Connection format*3
65536 colors 256 colors Human sensor
Multi channel Transparent System monitor
Intelligent unit monitor Q motion monitor Servo
amplifier monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Ethernetdownload
A/FX list editor
Network monitor
Memory 9MB
MELSECNET/10
Gateway
Ladder monitor
CNC monitor
CC-Link
*2
Features
Standard interface, standard memory size
Connection format*3
65536 colors 256 colors Ethernetdownload
Transparent System monitor A/FX list editor
Q motion monitor Servoamplifier monitor Network monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Gateway
Ladder monitor
Memory 9MB
MELSECNET/10
Multi channel
Intelligent unit monitor
CC-Link
*2
Features
Standard interface, standard memory size
Connection format*3
65536 colors 256 colors Ethernetdownload
Transparent System monitor A/FX list editor
Q motion monitor Servoamplifier monitor Network monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Gateway
Ladder monitor
Memory 9MB
MELSECNET/10
Multi channel
Intelligent unit monitor
CC-Link
*2
Features
Standard interface, standard memory size
Connection format*3
65536 colors 256 colors Ethernetdownload
Transparent System monitor A/FX list editor
Q motion monitor Servoamplifier monitor Network monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Gateway
Ladder monitor
Memory 9MB
MELSECNET/10
Multi channel
Intelligent unit monitor
CC-Link
*2
Features
Standard interface, standard memory size
Connection format*3
256 colors Ethernetdownload Gateway
System monitor A/FX list editor Ladder monitor
Servoamplifier monitor Network monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Multi channel
Intelligent unit monitor
Memory 5MB
MELSECNET/10
Transparent
Q motion monitor
CC-Link
*2
Features
Standard interface, standard memory size
Connection format*3
16 colors Ethernetdownload Gateway
System monitor A/FX list editor Ladder monitor
Servoamplifier monitor Network monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Multi channel
Intelligent unit monitor
Memory 5MB
MELSECNET/10
Transparent
Q motion monitor
CC-Link
*2
Features
Standard interface, standard memory size
Connection format*3
16 colors Ethernetdownload Gateway
System monitor A/FX list editor Ladder monitor
Servoamplifier monitor Network monitor
USB RS-232 CF card I/F
Bus Direct CPUconnection Computer link
Ethernet
Multi channel
Intelligent unit monitor
Memory 5MB
MELSECNET/10
Transparent
Q motion monitor
CC-Link
*2
*1: With high-resolution graphic board. *2: RS-422 communication is possible by installing an RS-422 conversion unit at the RS-232 interface. *3: Bus, MELSECNET/10, CC-Link, and Ethernet are compatible only with Mitsubishi PLCs.
Functions bearing this mark are available only on GT15 series models. All other functions are supported by both the GT11 and GT15 series.GT15
8 9
Featu
res and
recom
men
ded
po
ints
More design freedom through flexible connectivity
For designers
Collect and organize information from various FA devices to display on a single screen for quick reference
For designers
Barcord Reader
Inverter
Servo
Alarm
PLC
MELSEC
Recipe
Logging
Central storage of FA device informationMulti-channel function*
v Monitoring of up to 4 channels of FA devices (PLCs, servo amplifiers, inverters, temperature controllers, etc.).v Monitoring of all FA devices on a single screen on the GOT. Easily designed monitor screens.
Up to 4 simultaneous communication channels!
*: The number of channels and functions, which can be used with the multi-channel function, vary according to the connection configuration. For details, see the "Notes for use" on page 55.
Optional function board is required. GT15...GT15-QFNB(MM)
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71C24-R2QX41POWERQ61P-A1
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QX41POWERQ61P-A1
AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
Brand "A" PLC
Brand "B" PLC Inverter
Temperature controller
Temperature controller
Temperature controller
Other brand PLCs MELSEC + Temperature controllers + Inverters MELSEC + MELSERVO
Stand-alone PLCs (FX, or other brand PLCs)
+ MELSECNET/10Example of communication unit combinations
Microcomputer, FX, other brand PLCs
MELSECNET/10
Servo amplifiers (pulse train type)
Serial communication unit
GOT rear face
Bus communication unit
m Examples of usage
Before... With multi-channel functions...
Required temperature controller programs = Increased PLC load.
Required computer link unit for temperature controller connection = Increased cost.
Requires no programs for temperature
controller = Reduces PLC load!
Requires no computer link unit for temperature controller connection
= Reduces cost!
Easy data exchange between PLCs
Stand-alone devices can be connected to the network
Up to 4 simultaneous communication channels Central management of alarms and parameters
Customers' needs
Ethernet
*1: No need to create screens to use the servo amplifier monitor function. For details on the servo amplifier monitor function, see the "Features and recommended points" on page 25. *2: Monitoring and writing of devices, which are equivalent to MELSEC-Q4A, are supported. CNC parameters can be specified by using the CNC monitor function. For details on the CNC monitor function, see the "Features and recommended points" on page 25.*3: GT15 requires an optional battery (GT15-BAT) in order to save clock data.
Brand "A" PLC
Brand "B" PLC
Brand "C" PLC
0123456789ABCDEF
POWER
AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
Wide selection of connectable FA devices
The GOT1000 Series flexibly adapts to systems comprising various models and brands of FA devices
v The GOT1000 series has expanded the range of connectable devices, permitting connection to both Mitsubishi and other brand PLCs. (10 brands, including Omron, Yokogawa Electric, etc.)
v Connection with Mitsubishi servo amplifiers is possible to monitor parameters on flexibly designed screens.*1
v Also connectable to temperature controllers, and to Mitsubishi inverters and CNCs*2.
v The GT15 is equipped with a high-speed RS-232 interface as standard. Moreover, RS-422 communication is possible by installing an RS-422 conversion unit at the RS-232 interface.
v The GT11 is equipped with high-speed RS-232 and RS-422 interfaces (standard items) which can be used in an alternating manner, thereby enabling multiple GOTs to be connected.
v Internal clock function permits the use of alarm display and clock functions even when connected to a PLC which has no clock.*3
NEW
Other brand temperature controller
Mitsubishi PLC
FX2N-32MR
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
POWERRUNBATT.VPROG.ECPU.E
FX2N-32MR
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
POWERRUNBATT.VPROG.ECPU.E
POW
RUN
FX3UC-32MT-LTSTOP
ESC
OK
RUN
LRUN
BAT
ERR
LERR
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
Mitsubishi servo amplifier
NEW
[Mitsubishi PLC] FX3U; [Other brand PLCs] KEYENCE: KV-700/1000; Matsushita Electric Works: FP-E; SIEMENS: SIMATIC S7-200 Series
Newly compatible PLCs
For connectable FA devices, see the "Connectable model list" on page 28.For connection format specific features, see the "Connection configuration" section on page 32.
Mitsubishi CNC
Mitsubishi inverterPULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
Improved Microcomputer connectionFor wider GOT support of applications
v Offers wider communication protocol support (15 types).
• Mitsubishi A/QnA/Q-computer link unit (8 types)
• GOT-A900 series compatibility (2 types)
• GOT-F900 series compatibility (2 types)
• Digital Electronics (Proface) memory link format (3 types)
v Expanded D-device support, with the following devices now
supported: Bit devices: L, M, SM; Word devices: R, SD.
v The number of interruption points has been increased from 1 byte to a maximum of 4 bytes, enabling simpler control program design.
v The GOT1000 series has an internal clock function which can be used for alarm displays and clock functions.*
*: GT15 requires an optional battery (GT15-BAT) in order to save clock data.
Easy monitoring of temperature controller
data on GOT
GT11
Resolution: QVGA 320 x 240Display colors: 16 gray scales
Handy GOT/STNGT1155HS-QSBD (DC type)
Resolution: QVGA 320 x 240Display colors: 16 gray scales
STNGT1150-QLBD (DC type)
Resolution: QVGA 320 x 240Display colors: 256 colors
Handy GOT/STNGT1155HS-QSBD (DC type)
Resolution: QVGA 320 x 240Display colors: 256 colors
STNGT1155-QSBD (DC type)
5.7''Type
5.7''Type
5.7''Type
5.7''Type
Standard models offer a full array of basic functions for stand-alone use
There's a model for your needs.All 19 models in the GOT1000 lineup
offer the same user friendliness.
Features
Standard interface, standard memory size
Connection format
256 colors Vertical display Transparent
USB
Direct CPUconnection Computer link CC-Link
Connection formatDirect CPUconnection Computer link CC-Link
System monitor A/FX list editor
RS-422RS-232 CF card I/F Memory 3MB
Features
Standard interface, standard memory size
16 gray scales Vertical display Transparent
USB
System monitor A/FX list editor
Features
256 colors Transparent System monitor A/FX list editor
Features
16 gray scales Transparent System monitor A/FX list editor
RS-422RS-232 CF card I/F Memory 3MB
Standard interface, standard memory size
Connection format
USB
Direct CPUconnection Computer link CC-Link
Connection formatDirect CPUconnection Computer link CC-Link
RS-422RS-232 CF card I/F Memory 3MB
Standard interface, standard memory size
USB
*1 *1
RS-422RS-232 CF card I/F Memory 3MB
*1 *1
Functions with this mark are newly supported by the GT11 series, not only by the GT15 series.*1: Via G4 (AJ65BT-G4-S3) only.
coming soon coming soon
10 11
Featu
res and
recom
men
ded
po
ints
For greater freedom in creating beautiful screens that best suit your needs
For designers
Lead the way in information sharing between the office and worksite
Be alerted to worksite errors and collect worksite controller data from an office desk
Gateway function
*1: Requires MX Component Version3 or later. MX Component is a communication assistance tool that permits communications from a personal computer without having to identify the communication protocol and module. Data logging, collection, and saving is possible by programming at VBA. Applications that run in MX Component (MX Sheet, etc.) can also be used. *2: The devices required for Gateway function use at GOT1000 differ from those required at GOT-A900. For details, refer to the GOT1000 Series Gateway Function Manual.*3: Requires an SMTP (mail server). The mail transmission range depends on the SMTP specifications.*4: Be sure to use either GT15-QBUS or GT15-QBUS2.*5: Be sure to use either GT15-ABUS or GT15-ABUS2.*6: Communication between the Gateway function and a PLC is possible by using a single Ethernet communication unit.
v GOT (server) can be monitored from a personal computer (MX Component) to perform indirect reading/writing at PLC CPU devices being monitored by GOT.
v Even when monitoring other brand PLC CPUs, the server function can be used to perform reading/writing with the MX Component*1 alone.
v A GOT (server) can be monitored from another GOT (client) to perform indirect reading/writing at PLC CPU devices being monitored by GOT (server).
v The client function can be used to perform indirect reading/writing at PLC CPU brands other than the PLC CPU brand to which GOT (client) is connected.
v Communication is possible between GOT1000 and GOT-A900*2.
Server function & Client function
Mail transmission function
Collect data at a personal computer (server function)
Monitor other GOTs from a GOT (server function, client function)
[Devices required for gateway function use]
• Ethernet communication unit (GT15-J71E71-100)• Communication unit for connection to PLC• Optional function board (GT15-FNB or GT15-QFNB (MM))
Host personal computer
(client)
Brand "A" PLC Microcomputer board
MitsubishiPLC
GOT-A900(client)
Bus connection
RS-232 connectionRS-422 connection
Client function Server function
For designers
1
v Error information can be checked from a remote location away from the worksite.
v The alarm history display function can transmit alarm occurrence and recovery information by mail to a personal computer or cell phone.
Transmit mail from GOT to a personal computeror cell phone *3
3
2
2
2 1
GOT1000(Server)
GOT1000(client)
Data collected by MX Component
Worksite Office
Ethernet
Worksite
Worksite
Internet
Mitsubishi PLC
Mailserver
Bus connection
FTP serverfunction
3
4
GOT1000
Host personal computer (FTP client)Files checked by general-purpose software such as FTP client tools
Office
Mitsubishi PLC
GOT1000 (FTP server)
Bus connection
Mail transmissionfunction
[Gateway function compatible connection formats]
• Bus connection (MELSEC-Q)*4
• Bus connection (MELSEC-QnA/A)*5
• CPU direct connection• Computer link connection (MELSEC-Q/QnA/A)• CC-Link connection (via G4)• Ethernet connection *6
• CPU direct connection• Ethernet connection *6
Other brand PLC
Microcomputer board, personal computer, etc. (microcomputer connection)
Temperature controller connection
Connection Format (Between GOT and PLC)
FTP server function
Direct checking/editing of data in CF card (FTP server function)
4
v Files in a CF card in the GOT can be directly read and written from a personal computer (alarms, recipes, hard copies, etc.).
v No need to visit every factory to collect CF cards from every GOT when several GOTs exist or a GOT exists at a distant from a personal computer.
Mitsubishi PLC/Motion controller
Mitsubishi CNC (MELDAS C6/C64) connection
Vastly increased memory capacity
Draw without memory capacity worries
v GT15 is expandable to 57MB (optional) by using optional function board and CF card. GT15MM-MTBM: Standard 9MB memory (optional expansion up to 57MB) GT15MM-VNBM : Standard 5MB memory (optional expansion up to 53MB)
v Standard 3MB memory on the GT11.
v Design screens without worrying about memory capacity.
v BMP and JPEG* images can be used to create easy-to-understand screens.
*: JPEG format is supported only by the GT15.
GOT-F900
GT11
GOT-A900
GT15
Standard 512KB
Standard1MB Optional 8MB
Standard 9MB Optional 48MB
Standard 3MB
KB512
MB9
MB3
MB57
x6
x9NEW
An assortment of fonts allows more expression
Dramatically improved display is attractive and easy to view
v Supports Windows® compatible fonts*.
v When using a Windows® font, the font style (italics, underline, italics underline) can also be specified.
v Standard fonts, high-quality fonts, and TrueType fonts can be used in Gothic or Mincho styles*.
v Attractive characters in all sizes. TrueType fonts can be used.
v The Unicode2.1 compatible standard font, high-quality font, and TrueType font, display sharp and attractive characters in all languages.
v Create elaborate, high-quality screens that are both attractive and easy to view.
Font Size StyleStandard font
High-quality font
TrueType font
Windows® font
6 x 8 dot
12 dot
16 dot
12 dot
16 dot
24 to 128 dot
8 to 128 dot
Gothic
Gothic
Gothic / Mincho
Gothic / Mincho
Gothic / Mincho
Gothic / Mincho1
*: Gothic and Mincho styles cannot be used together in the standard font.
*: All TrueType (other than vertical scripts) and OpenType fonts can be displayed.
Component layering (Layer function)More freedom in screen design
v Component (objects, figures) layering increases the freedom of design.
v Display layering is possible for components such as changing numerical values and graphs, line graphs, bar graphs, photo data, and pointers, etc.
v Offers effective use of a limited display area by allowing comments to be placed on lamps.
Error occurence
Front layer~Back layer Front layer~Back layer
Back layer
Front layer Front layer
Layer graphsComment & lampPhoto data & pointer
Back layer
12 13
Featu
res and
recom
men
ded
po
ints
For designers
Intuitive support tools for designing screens with graphics
For designers
Increase design efficacy with an impressive array of clever functions
Script FunctionMore flexible screen design with improved work efficiency and customization functions
v GOT's unique programs allow for changes of display depending on projects and screens.
v Controlling GOT display by using scripts of GOT can reduce the load on PLCs (PLC CPU, microcomputer, etc.) dramatically.
1. Project script / screen script
Kana-Kanji conversion function
Easy-to-read item management using Kanji
v This function enables the conversion of text entered in Kana (ASCII code) to Kanji. Users are allowed to enter operator names and product names in Kanji.
v After entering text with input keys (key code switches created by users), press Kanji conversion key (key code switch) to display the text in Kanji in Ascii input field.
v Within ASCII text, the cursor movement function enables users to move the cursor to any place in order to add characters.
v Drawing and display control functions can be specified for every object, allowing objects to easily be used in other projects.
v Scripts make screen display control highly flexible by changing properties (colors and display positions) and making the object design process flexible.
v Input support function of the GT Designer2 make it easy to specify functions and properties, thereby preventing spelling errors and reducing the time to look up control statements.
2. Object script*
m Example of how to use object script (draw straight line on graph display)
m GT Designer2 script editor screen (object script only)
*:Optional function board is required. GT15...GT15-FNB or GT15-QFNB( M)
Optional function board is required. GT15...GT15-FNB or GT15-QFNB( M)
Edit and insert selected items by using statement examples being displayed
Edit scripts directly
Select functions and properties from the item list
Check contents of a selected item
clear_object();
[w:TMP0003] = ([w:D0] + [w:D1] + [w:D2]) / 3;
[w:TMP0001] = 320 - (320*([w:TMP0003] /1000));
d_line(0, [w:TMP0001], 380,[w:TMP0001], 0, 3, 255);
[w:D0003] = [w:TMP0003];
// Delete the previous object (including a line).
// Calculate an average value.
// Calculate the position to display a line.
// Draw a line.
// Assign the average value.
Draw a line to show the average value according to monitor device values
[Comment registration]
[Example of comment group use]
Comment groups
Efficient input of extensive comment data by allotment
v Up to 255 comment groups can be created in addition to basic comments.
Multilingual support
Easy creation of a multilingual screen
Comment group 3: Line C commentComment group 2: Line B commentComment group 1: Line A comment
(1) Line-specific comment groups are created.
(2) Import
(3) Displayed comment group can be switched by device.
When "1" is selected When "2" is selected When "3" is selected
Switch-ing
If D10=1, Japanese displays
If D10=2, English displays
If D10=3, Korean displays
To switch between Japanese, English, and Korean screen
Example of comment group use
For D10 languageswitching device
(2) At a language switching device, specify the No. of the column to be displayed.(3) The displayed comment (language) changes.
(1) Create the Japanese, English, and Korean comments in their respective columns.
Line Aerror
Line B error
Line C error
Line A comment
Line B comment
Line C comment
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QX42-S1
QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
Q64P
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QX42-S1
QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
Q64P
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QX42-S1
QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
Q64P
Indi-vidually edited
v CSV / Unicode text format files can be imported. Different files can also be input to individual comment groups, allowing the comment input task to be distributed among several workers, greatly reducing the required input time.
v The drawing software allows easy column and line insertions and comment No. changes similar to those offered by Microsoft ® Excel.
v Line-specific comment groups can be created and displayed, and switching between those groups is possible, enabling easy integrated control of multiple lines in a single project's data.
v Language-specific comment groups can also be created, with switching between the different language screens.
v Different language comments can be created at each comment column No. to switch languages simply by specifying the desired column No. at a language switching device.
v Up to 10 columns* can be created for 1 comment No.
v Examples of use (for switching between Japanese, English, and Korean)(1) Create the Japanese, English, and Korean comments in their respective columns.(2) At a language switching device, specify the No. of the column to be displayed.(3) The displayed comment (language) changes. • Language-specific alarm display screens can also be easily created.
v Column comments can be created freely for applications, as well as for different languages.
Switch-ing
*: For details, refer to the "Comment Group" item.
14 15
Featu
res and
recom
men
ded
po
ints
For designers
For history management of production conditions and precise analysis of problem causes
For designers
Simplified maintenance through batch handling of recipe information
Logging function
Smooth operation from collection of various data to saving time series files
Optional function board is required. GT15...GT15-FNB or GT15-QFNB(□M)
Optional function board is required. GT15...GT15-FNB or GT15-QFNB(□M)
v Collecting data from temperature controllers and other units with GOT can reduce the load on PLC. · 250 device points per setting, 32 settings per project can be set.
v Collected data can be used for record and analytical purposes when being saved to a CF card. · Files can be saved in the GOT dedicated binary file, CSV and Unicode text file formats.
Historical trend graphEasy-to-read logging data in a graph display
v Data collected by the logging function can be displayed in a time series graph from a CF card as well as from a buffering area.
· Data collected by the logging function can be displayed in graph form. Past data can be displayed simply by pressing a scroll switch. · Displays a cursor, device value and time of the cursor position, allowing for enlargement or reduction of scales. · Up to 32 data can be displayed in a graph; up to 8 graphs can be added to a screen.
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
PLC
* Settings of the logging function are required in order to use historical trend graphs.
Temperature controller
Buffering area (GOT memory)
CF card
Collect device data from PLCs and temperature controllers into a buffering area
Save data in the buffering area to a CF card
Analyze data in the CF card (CSV or Unicode text file) on a personal computer
Display time and device value of a cursor position
Cursor display: Displays a cursor Cursor movement (return): Moves the cursor backward Zoom in: Enlarges the graph scale
Cursor Cursor Enlarge scale
Advanced recipeAutomated recipe operation without sequence programs
1. Extensive amount of setting files, device points, and record points.
3. Easy handling of recipe data at GOT
v A greatly expanded capacity permits up to 2048 files and 32767 device points.
v Up to 240 device records can be handled by a single advanced recipe setting file.
2. Flexible recipe data can now be created.v Flexible recipe data can be created by combining advanced recipe settings and records.
v Reading/writing is performed by specifying the recipe No. and record No., eliminating the need for a trigger device at each file. This reduces the number of required devices, and permits trigger device concentration.*1
v Up to 2048 blocks are possible, with 1 block comprising a sequential word device and random word device (1 point), and a bit device (1 point).
v Because devices also permit bit and word combinations and random device settings, there is no need to concentrate the sequential devices, thereby economizing on the number of device points.
v Advanced recipe files can be edited on a personal computer.*2
*1: The "recipe No. saving device", the "record No. saving device", and the "external control device" advanced recipe common settings can be specified at the advanced recipe device dialog box in GT Designer2 (these settings are required when using an advanced recipe). Recipe data reading and writing occurs in accordance with external device ON/OFF switching, and that data displays onscreen. (It is also possible to specify a trigger device for reading/writing of each advanced recipe setting.)*2: The advanced recipe file has a binary format. It must therefore be converted to a CSV file or Unicode text file by using GT Designer2 or the GOT's utility. After being converted, only the device values can be edited.
Select a recipe file
Select a record andexecute the recipe
This function allows material combination data and processing conditions data, etc. (device value) to be held at GOT, with only the required data being written/read to and from the PLC.
Advanced recipeinformation screen
Advanced reciperecord list screen
Advanced recipe setting 1: Curry
D1000
D1001
D1002
D1100
D1101
D1102
Beef
Pork
Chicken
Onion
Potato
Carrot
Record 1Beef Curry
Record 2Pork Curry
Record 3Chicken Curry
300
0
0
400
300
200
0
300
0
500
400
250
0
0
300
600
200
150
Advanced recipe setting
DeviceCommentDevice
Records (max. 240 records / setting)
Device blocks (max. 2048 blocks / setting)
Number of device points (max. 32767 points / setting)
An optional function board is required.GT15...GT15-FNB or GT15-QFNB (□M)
Usage example
GOT main unit
Max. 2048 settings / project
Recipe execution
v Recipes can be handled easily by GOT's utility function without having to create a recipe operation screen.
v The utility function permits the following operations: folder create/delete, advanced recipe file copy/delete/file name change, record write/read/consistency check.
v Advanced recipe files can be converted to CSV files or Unicode text files.
Wo
rkspace
Lib
raryed
itor
Tem
po
rary area
Dialo
g b
ox
Pro
perty sh
eet
16 17
Featu
res and
recom
men
ded
po
ints
Create designs the way you imagined them
For designers
v A setting content list can be displayed for the selected object or figure.
v Similar objects can be selected, and the color and font size can be set in one go.
v Multiple same-type objects and figures can be selected, and their color and character size, etc., can be batch-changed.
List display of object & figure setting content
v Language switching, security level change and on/off image switching of objects can be checked with the GT Designer2 on a personal computer.
v Consistency checks between the GOT's project data and the personal computer project data can be performed.
v This allows project data inconsistencies to be identified, thereby reducing unnecessary uploads and downloads.
v GT Designer → GT Designer2 compatibility*2
GT Designer2 is compatible with project data created by GT Designer.
v GOT-900 → GOT1000 compatibility*2
GOT1000 is compatible with project data created at GOT-900.
v Settings of the following functions can be imported/exported: logging, advanced recipe, advanced user alarm, recipe, alarm history and comment registration.
v Device data, range settings, device values, and comments, which have been created in a CSV/Unicode text file format, can easily be imported/exported to and from the GT Designer2.
v A component editing screen displays by double-clicking a registered component at the library workspace.
v Editing of registered components is quick and easy.
Dedicated component editing screen
v Placing objects in a temporary area facilitates smoother screen creation and screen layout change operations.
Smoother screen creation
Screen previewEasy confirmation of screen display
Improved import/export function
Higher efficiency by using familiar software
v The drawing software can display window screens (key window, overlapping window, superimposed window) just as they will appear at GOT, allowing them to be previewed.
v The key pad can
be displayed just as it will appear at GOT, allowing its position, size, and appearance etc., to be checked.
Forward compatibility
Reliably compatible with existing GOT projects reuse work friendly to customer existing resources compatible
Project data consistencycheck function
Better project data maintenance efficiency
*1: Compared to Mitsubishi Electric's GT Designer.*2: Forward compatibility does not extend to certain data and functions. Moreover, GOT1000 screen data cannot be used at GOT-900.
It's easy to see the entire project so the screen to be edited can be selected right away.
The device, color, and figure of components can be batch-changed in screen or category units, even when located on multiple screens.
Frequently used components can be registered as "favorites", permitting quick access to an object or figure.
An intuitive tree display,with easy copying and deletion
Project workspace
Category workspace
Library workspace
*: "Category" refers to objects or figures that have been grouped according to purpose.
v A setting content screen displays by double-clicking the object or figure.
v Figure changes are immediately reflected onscreen.
This allows work to be performed while checking the onscreen results, thereby simplifying the process and reducing setting errors.
Object & figure setting screen
*: This is possible at the "Property Sheet" as well.
Version2
Reduction in screen drawing time by half*1
Windows®stan-dard operability
and menuconfiguration
Data compati-bility with
GT Designer
Reduction inscreen drawing
time by half
Display all settings in a list
Start wizard
Easy to set system settings, screen switching settings, multiple communication settings
v Interactive wizard helps users create a new project by configuring necessary settings for the GOT1000.
Wizard function
User-friendly setting procedure puts even beginners at ease
Edit a spreadsheet with software such as Microsoft Excel
import /export
Read created data into the GT Designer2 (Import)
Save contents of settings of the GT Designer2 to CSV/Unicode text files (Export)
Window previewDisplay of actual GOT screen
Example of how to switch languages
Select column No.1 Select column No.2
Select a column No. of the comment group to be displayed
Column No. of comment group
Con-sistencycheck
vThe GT15 lineup offers an array of display colors depending on usages. GT15MM-MTBM : Standard model offers a 256-colors display. 65536 colors are
available when the multi-color display board is installed. JPEG and BMP images can be used at the troubleshooting screen, etc., for vivid and easy-to-understand displays.
GT15MM-VNBM : Standard model offers either a 256-colors or 16-colors display.
vThe GT11 is available with either a 256-colors display or a monochrome (black & white) display. The 256-colors type features a long-life backlight with a lifespan of 75,000 hours or more. The monochrome (black & white) display offers a 16 gray scales for improved expression.
vA high intensity, with a wide-view angle and vivid colors offers sharp and attractive displays.
vA high transmissivity protection sheet* is available to protect the screen and prevent reflection, resulting in a clear, easy-to-view screen.
18 19
Featu
res and
recom
men
ded
po
ints
Efficient debugging
For designers
256 colors65536 colors
STN monochrome 16 gray scales STN color, 256 colors
GT15
State-of-the-art operation environment
Drawing, computing, communication; a triad of high-speed response functions
Dramatically improved GOT total response
65536-colors full color / monochrome 16 gray scales
Sharp display that's easy to view
The GOT1000 Series offers faster response in drawing, computing, and communication, reducing monitoring and operation stress.
v High-speed drawing of figures and characters was realized through the development of drawing chip especially for the GOT1000 Series.v Sharp and quick drawing of complex, layered component screens, and detailed photographic data.
v High-speed RS-232 communication (max. 115.2kbps).v GT15 high-speed communication is possible by bus connection.v High-speed communication is possible for connections with both Mitsubishi and other brand PLCs.
v Ultra high performance processing power to satisfy the most complex and demanding of applications.
Easy switching between different languages
Accommodates production site globalization
v The Unicode2.1 compatible standard font, high-quality font, and TrueType font, display sharp and attractive characters in all languages.
v Correctly display Simplified Chinese and Traditional Chinese characters *1 (GT15 only)
v Allows the creation of elaborate, high-quality screens that are both attractive and easy to view.
vOne-touch switching between different-language screens*2
accommodates different languages spoken by production site operators.
For operators
GT11
Response comparison with GOT-900 series
GOT- 900
GOT1000
For connectable PLC models, see the "Connectable model list" from page 28. For connection format specific features, see the "Connection configuration" section from page 32.
NEW
NEW
Equipped with a high-speed drawing chip (GT15 only). High-speed drawing
High-speed communication
GT11: Equipped with 64-bit RISC processor GT15: Equipped with 64-bit super-scalar RISC processor
High-speed computing
Bus connection
CPU direct connection
Computer link connection
MELSECNET/10 connection(Transient)
CC-Link (ID) connection(Transient)
Ethernet connection
Other brand direct connection[Yokogawa Electric. FA-M3]
FX direct connection[MELSEC FX3UC]
0.2 0.4 0.6 0.8 1.0
*1: Optional function board is required. GT15...GT15-FNB or GT15-QFNB(MM)*2: For function details, see the "Multilingual support " section on page 12.
Version2
GX Simulator GX Developer
Click with mouse
Programming softwareVirtual PLC
Virtual GOT1. Debugging is possible from a single personal computer, without actual GOT and PLC operation required.*1
3. Device monitor function permits monitoring of a wide array of devicesv Monitoring is possible for displayed devices. (GOT internal devices can also be monitored.)
vIn addition to displayed devices, monitoring is also possible for devices with common settings, as well as for overlapping windows 1 & 2, and superimposed windows 1 & 2.
v Because devices can be registered freely, it is possible to register multiple devices which are to be monitored.
2. Debugging is possible by connection with a PLC, without actual GOT operation requiredDebugging can be performed using a direct CPU connection between a personal computer (GT Simulator2) and a PLC, without actual GOT unit.Connection is possible to Mitsubishi and Omron PLCs*2.
4. Powerful support of customer specifications compatibility checks and document creationvWhile observing the operation image, the customer's screen specifications can be arranged without actual unit operation.
v Display screen snapshots can be saved to the personal computer's hard disk as BMP/JPEG files that are extremely useful when creating specifications and operation manuals.
*1: Requires GX Simulator (ladder logic test tool). *2: For connectable PLC model information, see the "Connectable model list" on page 28.[Unsupported functions] For lists of functions which cannot be simulated (utility function, optional function, etc.), refer to the GT Simulator 2 Version 2 Operation Manual.
GX Developer
Lo
ad p
rog
ram
Lo
ad d
rawin
g
data
Drawing software
Programming softwareCommunication / monitoring
Virtual GOT
GX SimulatorVirtual PLC
Sequence program
Omron PLC
RS-232 / RS422 connection
Mitsubishi PLC
RS-232 connection
Screen imageat personal computer
GT Simulator 2
Click with mouse
v A GT Simulator2 screen debugging function permits screen editing in GT Designer2 with the results immediately verifiable in GT
Simulater2, thereby greatly reducing debugging man-hours.v The input to a touch switch is simulated by clicking on the touch switch on GT Simulator2 with the mouse. The result of input to the touch switch can be confirmed by a display change on GT Simulator2, the device monitor screen on GX Simulator, or the ladder monitor of GX Developer.v GT Simulator2 can be used in combination with a sequence program created in GX Developer to recreate the screen motion, allowing debugging to be performed in an intuitive manner.v System alarm and script error information can be checked in GT Simulator2, even if no system alarm settings have been specified in GT Designer2.
RUN
Approx. times faster response4
*: The protection sheet is an optional item.
One-touch
language switching
[Using MELSEC-Q series]
GT15 response performance comparison
Randomly monitor 250 numerical displays (word devices) (1.0 for computer link connection is a comparison standard)
Connectable PLCs
Mitsubishi PLC (Q/QnA/A/FX series)
Mitsubishi PLC (MELDS C6/C64)
Omron Corp. PLC*2
PLC ⇔ Personal Computer Connection
RS-232/RS-422
RS-232
20 21
Featu
res and
recom
men
ded
po
ints
For minimizing procedure man-hoursand setup
For initial startup & adjustment operators
*: Requires an Ethernet communication unit (GT15-J71E71-100) installed in a GOT main unit where basic functions have also been installed.Downloading/uploading other than the Boot OS and OS installation is possible. (Resource data can only be uploaded.)
RS-232interface
CF cardinterface
RS-232interface
RS-422interface
GT11
CF cardinterface
HandyGOT
RS-232interface
CF card interface
GT15
Up to times faster12Mbps 20
Equipped with front USB interfaceEasy cable connection without opening the cabinet
FA transparent functionEdit sequence programs without opening the cabinet
*: Compliance cannot be guaranteed in all customer environments. Moreover, the IP67f rating does not apply when a USB cable is connected.
IP67fStandard item (with IP67f-rated port cover installed)
With USB cable
GT15 GT11
v A front USB interface allows cables to be connected without having to open the cabinet. Work efficiency is improved by eliminating the time-consuming process of opening and closing the cabinet door at GOT data transmissions.
v The USB interface is a standard item for all models. Data transmission can be up to 20 times faster than the previous RS-232 format, greatly reducing the time required for startup and adjustment.
v Equipped with an IP67f-rated port cover as standard. When secured by screws, the cover complies with the IP67f* standard.
v The IP67f-rated port cover is easily opened/closed by coin screws.
v Sequence program debugging, startup, and adjustment can be performed via GOT's front USB interface.*1 There is no need to open the cabinet and change cable connections. (Operation is also possible via the RS-232 interface.)*2
v When GOT is connected to a Mitsubishi PLC by bus connection*3 or direct CPU connection, program reading, writing, and monitoring can be performed via GOT.
Comparison of project data downloading times
GOT-900(RS-232)
GOT1000(USB)
Data transmission time
38.4kbps
Short Long
*1: Requires GX Developer Version 8.22Y or later.*2: When the GOT internal RS-232 interface is used to connect to the PLC, GOT can only be connected to a personal computer by the USB interface.*3: When multiple GOT units are connected by a bus connection, the FA transparent function can be used at each of the GOT units.
MELSECNET/10, etc.
USB/RS-232
*: For software access ranges when using the FA transparent function, refer to manual for the software being used.
GX Developer
Y100
Y70
M0
M500
Y100
Y70
M0
M500
Bus connection or direct CPU connection
High-speed downloading/uploading* via Ethernet
Project data can be maintained from a remote location
v Project data from a personal computer at a remote site can be downloaded and uploaded to a GOT terminal by way of Ethernet.
Ethernet
DownloadUpload
DownloadUpload
Mitsubishi PLC
Worksite
OfficeGT Designer 2
Up to times faster100Mbps 20
Comparison of project data downloading times
GOT-900(RS-232)
GOT1000(Ethernet)
Data transmission time
38.4kbps
Short Long
Standard-item RS-232 interface
For GOT data transmissions & a variety of external connections
v Both the GT15 and GT11 have RS-232 interfaces located in convenient positions (bottom, and side face, respectively) for cable connection.
v Used for FA device connection, data transmission, bar-code reader connection, etc.
Up to times faster4
Comparison of project data downloading times
GOT-900(RS-232)
GOT1000(RS-232)
Data transmission time
38.4kbps
115.2kbps
Short Long
Standard-item CF card interfaceEasy GOT data transmissions & setup
v All models are equipped with a CF card interface as standard.
v Permits rapid GOT data transmissions even when GOT is not connected by cable to a personal computer.
v When using multiple GOT units, a single CF card enables a quick GOT setup procedure simply by copying the data to each GOT unit.
coming soon
22 23
Featu
res and
recom
men
ded
po
ints
Rapid diagnostics and identification to minimize machine downtime
Advanced alarmFrom error detection to recovery
The GOT1000 Series offers quick error detection and cause identification, enabling a speedy system recovery.
(upper step)Alarms by line
Alarms by unit
Alarm content
Step1
(middle step)Step2
(general step)Step3
Troubleshooting
(details screen)Step4
Advanced alarm features
4-step alarm notification
Alarm observationfor up to
32767 devices
Alarm observationsubjects
Display of active and recovery-completed alarms
Display of activealarms only
Popup display
Alarm display settings History file saving
Alarm Transport G alarm display
Minor alarm display
Transport G major alarms display
GroupGroup
Level
Combination level
& group
Level
Max. of 255settings
Alarm observationsettings
M0M1M2M3M4M5M6M7M8M9
Transport GTransport GTransport GTransport GTransport GProcess GProcess GProcess GProcess GProcess G
Mid-levelMid-levelMid-levelMid-level
MajorMajorMinorMinorMinorMinor
Unit "B" observationsettings
1. A wider monitoring range protects even large-scale systems.2. Rapid detection and corrective action for a wide array of alarms.3. Easy-to-understand error displays for the operator.4. Improved system alarms.5. Support in identifying alarm causes.
v Alarm observation is possible for up to 32767 devices, with a maximum of 255 alarm observation setting groups.v 3 types of alarm displays can be specified for a single alarm observation setting.v Up to 32767 alarms can be saved in the alarm history.v Batch display of large amounts of alarm information in large-scale systems, and unit-specific classification for easy management.
1. A wider monitoring range protects even large-scale systems.
v The use of colors and popups produce easily recognizable alarm displays.vEnsures that alarms are not overlooked and that the alarm content is understood, resulting in a speedy system recovery.
3. Easy-to-understand display
v The PLC/GOT/Network monitoring subject can be specified in advance, with only those specified alarms being displayed.vIf desired, only the active alarms are displayed. An alarm history display and history file saving are also possible.
4. Improved system alarms
v Alarm occurrence conditions can be displayed in time-series graph form.v Alarm occurrence counts can be displayed in bar-graph form.v A graphical statistics display facilitates efficient analysis of error causes.
5. Support in identifying alarm causes (utility function)
2. Rapid detection and corrective action for a wide array of alarms.
v Alarm occurrence conditions can be divided into 4 steps, and conveyed to the operator in an easy-to-understand, step-by-step format.
Group-specific & level-specific displays
v Alarms can be classified by group and level, with only the specified alarms being displayed.
v This makes it easy to identify the locations and types of alarms, even when many alarms have occurred, and permits the higher priority alarms to be handled first, resulting in a speedy system recovery.
Where isthe error?
What kindof error?
When willrecovery occur?
v The 4 steps shown above can be freely defined to suit the application in question, with switching between the step displays performed by the step switching device or by touch-screen operation.
When multiple alarms occur, the above format permits the operator to quickly organize and identify the alarm conditions (where, what kind of alarm), resulting in effective troubleshooting.
1. Alarms by line (upper step)2. Alarms by unit (middle step)3. Alarm content (general step)4. Troubleshooting (details step)
For
exa
mpl
e...
1. By groupAlarms are divided into groups (transport unit group, processing unit group, etc.), with alarms displaying only for the specified groups.
2. By levelAlarms are divided into levels (major, mid-level, minor), with only the specified level alarms displaying.
3. Combination group & levelOnly the specified group and level alarms display.
For maintenance personnel
Details display
Alarm popup display
A popup display format ensures that user alarms and system alarms are not missed. The background color can be specified.
Display subject switching
Display switching is possible to display only active alarms or to display all content.
Comment display color
Comment display colors can be specified for each alarm status (occurred, restored, and checked) and for each level and group, etc.
Sorting
A sorting function permits the display order of the date & time, level, group, alarm status, occurrence count, and downtime items to be changed.
Cursor display color
The cursor display color can be specified. Alarm displays are harder to miss, and the freedom of screen design has been increased.
Floating alarm display
Permits the entire text of long comments which cannot be contained in the display area to be read.
JPEG images can be displayed in the details display area.
Device "A" error
Out of material
Materialreplenishment
Line "A" stops
Unit "A" observationsettings
Alarmoccur-rence
24 25
Featu
res and
recom
men
ded
po
ints
Convenient method for minor program changes onsite
List editor for A / List editor for FX
v MELSEC-A series, FX series PLC sequence programs can be edited in a list format (instruction word).v Permits minor program changes onsite, even without peripheral devices.v The GT15 permits sequence program editing while viewing the ladder (combined with the ladder monitor function).
Sequence program monitoring & troubleshooting
Ladder monitor function
v Monitoring of Mitsubishi PLC sequence program and various searches of devices can be performed. • Monitoring in ladder format. • Device values and Timer (T)/counter (C) setting values can be changed. • A coil (or contact) can be touched to search for contacts (or coils) of the same device.*1
v When a problem occurs, an alarm history can be displayed, and a back-tracking ladder search can be performed to find the contact which triggered the alarm.
For maintenance personnel
Requires optional function board.
NEW
GT15...GT15-FNB or GT15-QFNB (MM)GT11...GT11-50FNB
At-a-glance monitoring of MELSECNET network status
Network monitor function
v Network status of the MELSECNET/H, MELSECNET/10 and MELSECNET II can be monitored on a dedicated screen.
v Communication line, information from the host and other stations can be monitored to check the communication status.
*1: MELSEC-Q/QnA series only.
*2: Supported only if the Q series motion controller CPU has SV13/SV22 OS version. Moreover, available functions of Q series motion monitor vary according to the CPU type.
Easy adjustment of Q series motion controller
Q series motion monitor function
v Monitoring of servo amplifiers and parameter settings of Q motion controllers can be performed.*2
v Monitoring and parameter settings can be performed for up to 3 units of Q172(N) /Q173(N) on the same base unit.
Easy-to-understand display of buffer memory values and I/O information
Intelligent unit monitor function
v Buffering memory values of intelligent function units and ON/
OFF status of I/O units can be monitored and changed.
v When a QCPU (Q mode) is in use, CPU operating status and existing errors can be monitored by PLC diagnosis.
*3: Available monitoring functions vary according to the servo amplifier type.
*4: Supported by GT15 series XGA and SVGA models.
Easy startup and adjustment of servo amplifier
Servo amplifier monitor function
v In a system which outputs pulse strings, GOT can be connected to a servo amplifier in a serial connection to perform the following operations: setting up, monitoring, alarm display, diagnosis, parameter setting, and test operations.*3
v When multiple servo amplifiers are connected, monitor screens can be easily switched on a GOT by specifying station numbers.
Space and cost saving because no dedicated display device is required
CNC monitor function
v When a MELDAS C6/64 is connected, position display monitor, alarm diagnosis monitor, and tool offset parameters can be set on GOT as well as on a display device dedicated to MELDAS.
v Up to 64 CNC units can be monitored in an Ethernet connection. Only a control station can be monitored in a MELSECNET/10 connection.
*4
List editor for FX
List editor for A
Convenient maintenance tools
Color-coded front face LED & maintenance schedule notification function
Backlight maintenance required.
mMaintenance schedule notification function (GT15 only)
v The backlight lifespan can be monitored by an automatic "power ON time" count function, combined with a 2-stage maintenance schedule notification function.
v Monitored subjects • Backlight, display area (power ON time) • Touch-keys (key pressing count) • Internal flash memory (writings count)
v Facilitates scheduled maintenance, thereby preventing system malfunctions.
1. Color-coded front face LED
2. Maintenance schedule notification function (GT15 only)
v The color of the LED on the front of the GOT unit indicates whether the backlight is OFF or has expired.
2nd notification
Backlight maintenance required soon.
1st notification
Requires optional function board.GT15...GT15-FNB or GT15-QFNB (MM)
Battery required.GT15...GT15-BAT
[POWER LED: Color-coded message]
Green ON
Orange ON
Orange/green blinking
OFF
When normal power is being supplied
When in screen-save mode
When backlight life has expired
When power is not being supplied
System alarm
occurs
System alarm
occurs
Sequence device monitoring / changes
System monitor function
v Mitsubishi PLC CPU devices can be monitored and changed. • Monitoring can be performed by selecting the device to be monitored, or by specifying the initial device. • The timer (T) / counter (C) current values and setting values can be changed.v A special function unit's buffer memory (BM) can be monitored and changed.v The display format (decimal / hexadecimal) and the device comment display status (ON/OFF) can be switched.
For easy monitoring and other operations ofMitsubishi FA devices
Optional function board is required for functions shown on this page.GT15...GT15-FNB or GT15-QFNB (MM). GT15-QFNB (MM) is required in order to use Q/QnA ladder monitor function.
26 27
Featu
res and
recom
men
ded
po
ints
Unlimited mobility wherever you are within a facility
Handy GOT
Flexible usage and connectivity of Handy terminals
vRestricts access to certain operations (manual/auto switching, mode selection, setup change, etc.) to authorized operators.
Portable and wearable Handy terminals can also be mounted on a wall or a machine
mKey type selector switch
vGT1155HS-QSBD has 256 colors; GT1150HS-QLBD has 16 gray scales.
mDisplay equivalent of GT11
vImproved safety by using 2 break contacts connected in series, either of which can execute a stop command when being switched off.
v3 position switch is adopted. (OFF-ON-OFF) Connected to an external device as a dead-man switch, grip switch can be used for the immediate execution of a command to stop a machine.
mEmergency stop switch of 2 break contacts
mGrip switch
vWired directly to an external device input as push-button switches, 6 operation switches can be used to operate and stop a machine. Furthermore, the operation switch names can be changed as desired.
vThe control panel is equipped with an LED lamp (green) for verifying operation of these switches.
m6 operation switches
vThe CF card interface permits fast GOT data transmission.
mCF card interface
vThe USB interface permits fast data transmission between GT Designer2 and GOT.
mUSB interface (standard item)
vThe RS-232 interface is provided for GOT data transmission when the USB interface is not used.
vEmergency stop switch guard (GT11H-50ESCOV)
mRS-232 interface
vEither the RS-232 or RS-422 format can be selected for communication with connected devices.
mRS-232 / RS-422 communication
mOptional devices
RS-232/RS-422 RS-232/RS-422
RS-232/RS-422
FA devices
To power supply and operation switches
To power supply and operation switches
FA devices
Model name Connectionconfiguration Connected FA device Connection port External connection cable FA device interconnection relay cable
A series computer link unit, QnA/Q serial communication unit, Mitsubishi inverter, other brand PLC, microcomputer, servo, CNC, temperature controller
A series computer link unit, QnA/Q serial communication unit, Mitsubishi inverter, other brand FA device, microcomputer, servo, CNC
External connection cable GT11H-CMMM-37P
External connection cable GT11H-CMMM
PLC interconnection relay cable
FX0S, FX0N, FX1NC, FX2NC,
FX3U, FX3UC,
CPU programming port
FX1S, FX1NCPU programming port or FX1N-422-BD
FX2NCPU programming port or FX2N-422-BD
A, QnA, A motion controller CPU programming port
CPU programming port
Connectable FA devices (see "Connectable model list" on page 28)
Connectable FA devices (see "Connectable model list" on page 28)
GT1155HS-QSBD
GT1150HS-QLBD
GT11H-CMMM-37P MMM: 30(3m)/60(6m)/100(10m)
GT11H-C15R4-8P(1.5m)
GT11H-C15R4-25P(1.5m)
GT11H-CMMM
MMM: 30(3m)/60(6m)/100(10m)
GT11H-C30-37P
Q GT11H-C15R2-6P(1.5m)
GT11H-C30-37P
GT11H-CMMM
MMM: 30(3m)/60(6m)/100(10m)
When the connection distance between Handy GOT and PLC exceeds the cable length shown in the table, the user must fabricate an FA device interconnection relay cable. For further connection cable details, refer to the Handy GOT Operation Manual.
Termination of GT11H-CMMM is required in accordance with the devices to be connected.
Termination of GT11H-CMMM is required in accordance with the devices to be connected.
To be fabricated by user.
To be fabricated by user.
1 2
1
1 2
Handy GOT
For RS-232 connection
For RS-422 connection
The connection distance between Handy GOT and PLC must not exceed 11.5m.
The connection distance between Handy GOT and PLC must not exceed 6m.
RS-422
RS-232
GT1155HS-QSBD/GT1150HS-QLBD Handy GOT FA device interconnection cables
vProtective sheet (GT11H-50PSC)
vCF cardvOptional function board (GT11-50FNB)vReplacement battery (GT11-50BAT)vExternal connection cablevPersonal computer connection cable (GT01-C30R2-6P (RS-232 cable)) (GT09-C20USB-5P (USB cable))
LED lamp for grip switch
Display area
Removable logo mark
Replaceable name label
Key type selector switchUSB interface
Emergency stop switch
6 operation switches
Lightweight, thin and easy-to-handle cable
CF card interfaceHook to attach neck strap
Hand strap
Grip switch
One-touch connection of optional cable
GT1155HS-QSBD : 256 colorsGT1150HS-QLBD : 16 gray scalesEquipped with touch switches equivalent of GT11.
coming soon
C o n n e c t a b l e m o d e l l i s tThe GOT1000 series allows connection to Mitsubishi PLCs and a variety of other FA devices.
Q00JCPU Q00CPUQ01CPUQ02CPUQ02HCPUQ06HCPUQ12HCPUQ25HCPUQ12PHCPU Q25PHCPUQ12PRHCPUQ25PRHCPUQJ72LP25-25QJ72LP25GQJ72BR15Q02CPU-AQ02HCPU-AQ06HCPU-AQ2ACPUQ2ACPU-S1Q3ACPUQ4ACPUQ4ARCPUQ2ASCPUQ2ASCPU-S1Q2ASHCPUQ2ASHCPU-S1A2UCPUA2UCPU-S1A3UCPUA4UCPUA2ACPUA2ACPUP21A2ACPUR21A2ACPU-S1A2ACPUP21-S1A2ACPUR21-S1A3ACPUA3ACPUP21A3ACPUR21A1NCPU A1NCPUP21A1NCPUR21A2NCPUA2NCPUP21A2NCPUR21A2NCPU-S1A2NCPUP21-S1A2NCPUR21-S1A3NCPUA3NCPUP21A3NCPUR21
MELSEC-Q series (Q mode)
MELSECNET/H remote I/O stationsMELSEC-Q series (A mode)
MELSEC-QnA series (QnACPU type)
MELSEC-QnA series (QnASCPU type)
MELSEC-A series (AnCPU type)
Series Model name
Busconnection
*1*2
CPU direct
connection
MELSECNET/10
*1*3
CC-Link(ID)*1*4
CC-Link (via G4)
*4
Ethernet
A2USCPUA2USCPU-S1A2USHCPU-S1A1SCPUA1SCPUC24-R2A1SHCPUA2SCPUA2SCPU-S1A2SHCPUA2SHCPU-S1A1SJCPUA1SJCPU-S3A1SJHCPUA0J2HCPUA0J2HCPUP21A0J2HCPUR21A0J2HCPU-DC24A2CCPUA2CCPUP21A2CCPUR21A2CCPUC24A2CCPUC24-PRFA2CJCPU-S3A1FXCPUQ172CPUQ173CPUQ172CPUNQ173CPUNQ172HCPUQ173HCPUA273UCPUA273UHCPUA273UHCPU-S3A373UCPUA373UCPU-S3A171SCPUA171SCPU-S3A171SCPU-S3NA171SHCPUA171SHCPUNA172SHCPUA172SHCPUNA173UHCPUA173UHCPU-S1FX0SFX0NFX1SFX1NFX1NCFX2NFX2NCFX3UFX3UC
MELSEC-A series (AnSCPU type)*13
MELSEC-A series *13
Motion controller CPU (Q series)
Motion controller CPU (A series) (large type)
Motion controller CPU (A series) (small type)*13
MELSEC-FX series
SeriesConnection configuration Connection configuration
*1: Supported only by the GT15.*2: When connecting multiple GOTs, note that the following GOT models cannot be used together:
GOT1000 series, GOT-A900 series, GOT800 series, and A77GOT.*3: When MELSEC/H is used in NET10 Mode, the GOT terminal cannot be connected directly to a
Remote I/O station.*4: CC-Link (ID): Connected as CC-Link (intelligent device station). CC-Link (via G4): Connected to a
CC-Link system via AJ65BT-G4-S3.*5: When using A Series computer link (C24 modules) with QCPU/QnACPU, only the device ranges
within QnACPU specifications are supported.The following devices cannot be monitored:· Devices that have been newly added to the QCPU/QnACPU.· Latch relay (L) and step relay (S).In the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.· File register (R)· Local devices
*6: Use CPU function version "B" or later in a multiple CPU system.*7: When using a bus extension connector box, it must be installed at an extension base. (It cannot
be installed at the main base.)*8: Use function version "B" or later for the CPU and MELSECNET/H network unit.*9: Does not support automatic system switch. (If there is only 1 GOT, plug the GOT cable into the
CPU of the control system to be monitored. If there are 2 GOTs, plug each of them into the respective CPUs of the "A" and "B" systems to be monitored.)
*10: Does not support automatic system switch. (Use the script to switch systems.)*11: With redundant system, the standby system automatically takes over the control if control
system goes down.*12: In Q4ARCPU redundant systems, GOT must be bus-connected to the last stage's redundant
system extension base A68RB version "B" or later.*13: Computer link unit software version "U" or later must be used for the A2SCPU, A2SHCPU,
A1SHCPU, A1SJHCPU, A0J2HCPU, A171SHCPU, and A172SHCPU computer link connections.The A0J2-C214-S1, dedicated computer link unit for A0J2HCPU, cannot be used.
*14: Only the following software version or later can be used to write data to the AnNCPU (S1), A2SCPU, A0J2HCPU, and A2CCPU. Earlier versions cannot be used.· AnNCPU (S1) : A "with link" status requires version "L" or later, and a "without link" status requires version "H" or later.· A2SCPU : Version "H" or later· A0J2HCPU (with link/without link) : Version "E" or later· A0J2HCPU-DC24 : Version "B" or later· A2CCPU : Version "H" or later
*15: Cannot connect to bus if an extension base is connected.*16: Use of the SV13, SV22, or V43 requires a motion controller with the following OS version
installed.
SW6RN-SV13Q□: 00H or later (00E or later when Q172CPU, Q173CPU and bus connection, or direct CPU connection exists)SW6RN-SV22Q□: 00H or later (00E or later when Q172CPU, Q173CPU and bus connection, or direct CPU connection exists)SW6RN-SV43Q□: 00B or later
*17: Only a USB interface is available on Q172HCPU and Q173HCPU units. The Q172HCPU and Q173HCPU can be accessed using a multi-CPU system QCPU RS-232.
*18: Use a unit with the following serial No.Q172CPU Serial No. K******* or laterQ173CPU Serial No. J******* or later
*19: Use a unit with the following serial No.Q172CPU Serial No. N******* or laterQ173CPU Serial No. M******* or later
*20: If an extension base is to be used, use the A168B.
MELSEC-Q series (Q mode)MELSECNET/H remote I/O stations
MELSEC-Q series (A mode)
MELSEC-QnA series
MELSEC-A seriesA series Motion controller CPU
QJ71C24QJ71C24-R2QJ71C24NQJ71C24N-R2QJ71C24N-R4QJ71CMOA1SJ71UC24-R2A1SJ71UC24-R4AJ71QC24AJ71QC24-R2AJ71QC24-R4AJ71QC24NAJ71QC24N-R2AJ71QC24N-R4A1SJ71QC24A1SJ71QC24-R2A1SJ71QC24NA1SJ71QC24N-R2AJ71UC24AJ71UC24A1SJ71UC24-R2A1SJ71UC24-R4A1SJ71C24-R2A1SJ71C24-R4A1SCPUC24-R2A2CCPUC24
RS-232RS-232RS-232RS-232RS-422/485Module connectorRS-232RS-422/485RS-232RS-232RS-422RS-232RS-232RS-422RS-232RS-232RS-232RS-232RS-232RS-232RS-232RS-422/485RS-232RS-422/485RS-232RS-232
RS-422/485RS-232RS-422/485RS-232RS-422/485RS-232!
!
RS-422/485RS-232RS-422/485RS-422/485RS-232RS-422/485RS-422/485RS-232RS-422/485RS-232RS-422/485RS-422/485!
!
!
!
!
RS-422/485
vFor computer link connection
CPU seriesModel CH1 CH2
Computer link modules/serial communication modules *1
mModules that can be connected with Mitsubishi PLC
*2
*2
*3
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4 *6
*4 *5
*5
*5
*5 *6
*5 *6
*5
*4
*2
*2
*2
*2
MELSEC-Q series (Q mode)*1
MELSEC-QnA series
MELSEC-Q series (A mode)MELSEC-A seriesA series Motion controller CPU
QJ71LP21QJ71LP21-25QJ71LP21S-25AJ71QLP21AJ71QLP21SA1SJ71QLP21A1SJ71QLP21SAJ71LP21A1SJ71LP21
QJ71BR11
AJ71QBR11A1SJ71QBR11
AJ71BR11A1SJ71BR11
vFor MELSECNET/10 connection
CPU seriesOptical loop Coaxial bus
MELSECNET/H(NET/10 mode), MELSECNET/10 modules
MELSEC-Q series (Q mode)
MELSEC-QnA series
MELSEC-Q series (A mode)MELSEC-A seriesA series Motion controller CPU
QJ71E71-100QJ71E71-B5QJ71E71-B2QJ71E71AJ71QE71N3-TAJ71QE71N-B5AJ71QE71N-B2AJ71QE71N-TAJ71QE71N-B5TAJ71QE71AJ71QE71-B5AJ71E71N3-TAJ71E71N-B5AJ71E71N-B2AJ71E71N-TAJ71E71N-B5TAJ71E71-S3
A1SJ71QE71N3-TA1SJ71QE71N-B5A1SJ71QE71N-B2A1SJ71QE71N-TA1SJ71QE71N-B5TA1SJ71QE71-B5A1SJ71QE71-B2A1SJ71E71N3-TA1SJ71E71N-B5A1SJ71E71N-B2A1SJ71E71N-TA1SJ71E71N-B5TA1SJ71E71-B5-S3A1SJ71E71-B2-S3
vFor Ethernet connectionCPU series Ethernet module *1
MELSEC-Q series (Q mode)
MELSEC-QnA series
MELSEC-Q series (A mode)MELSEC-A seriesA series Motion controller CPU
QJ61BT11QJ61BT11NAJ61QBT11A1SJ61QBT11AJ61BT11A1SJ61BT11
vFor CC-Link (ID) connection *1
CPU series CC-Link unit
MELSEC-Q series (Q mode)QJ61BT11QJ61BT11N
AJ65BT-G4-S3
vFor CC- Link (via G4) connection *1
CPU series CC-Link unit Peripheral deviceconnection unit
*1:RS-485 communication is not possible; therefore, A0J2-C214-S1 is not available.When using A Series computer link (C24 modules) with QCPU/QnACPU, only the device ranges within QnACPU specifications are supported.The following devices cannot be monitored:· Devices that have been newly added to the QCPU/QnACPU.· Latch relay (L) and step relay (S).In the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.
· File register (R)· Local devices
*2: With function version "A", CH1 or CH2 can be connected. With function version "B" or later, both CH1 and CH2 can be connected.*3: Only CH2 can be connected.*4: Either CH1 or CH2 can be connected.*5:: When connecting to A1SHCPU, A2SCPU(S1), A2SHCPU(S1),
A1SJHCPU, A0J2HCPU, A171SHCPU(N), A172SHCPU(N), use computer link module software version U or later version.
*6: Computer link module/serial communication module operate within the range of devices available on AnACPU. (R device cannot be used.)
*1: The GT11 can monitor only the master station.
*1: This is a "Ver.1 intelligent device station" permitting monitoring by transient and cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used.
*2: GOT can perform transient communication only with CC-Link units running function version "B" and software version "J" or later.
*1: Use function version "B" or later for the CPU and MELSECNET/H network unit.
*7
*8
*9 *8*10 *10*15
*18
*20
*18
*17
*14
*19 *19 *19 *19 *19
*16
*16
*16
*16
*14
*11 *11
*6
*6
*6
*6
*6
*6
*1
*12
*14
*1: When using an A-series Ethernet (E71 modules) with QCPU/QnACPU, only the device ranges within AnACPU specifications are supported except for the following devices.· Devices that have been newly added to the QCPU/QnACPU.· Latch relay (L) and step relay (S).(At the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.)· File register (R)· Local devices
Mitsubishi PLCs/motion controllers
28 29
Co
nn
ectable m
od
el list
[PLC/motion controller]In addition to a bus connection, GT15 can also be connected to a MELSECNET/10 or Ethernet network.The GT11 is equipped with RS-232 and RS-422 interfaces (as standard) which can be used in an alternating manner, thereby enabling multiple GOTs to be connected.
Computer-link con-
nection *5
Model name
Busconnection
*1*2
CPU direct
connection
MELSECNET/10
*1*3
CC-Link(ID)*1*4
CC-Link (via G4)
*4
Ethernet*1
Computer-link con-
nection *5
*14
j
j
j
j
j
2
2
2
2
j
j
j
j
2
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
j
2
j
j
j
2
j
j
2
j
j
j
j
j
2
j
j
j
j
j
2
2
2
2
j
2
j
j
j
j
j
j
2
2
2
j
j
j
j
j
j
2
j
2
2
j
j
j
j
2
j
j
2
2
2
2
j
j
j
j
2
j
j
2
2
2
2
j
j
j
j
2
2
2
2
2
22
j
j
2
2
2
j
2
2
2
2
22
j
j
j
2
j
2
*1: RS-422 or RS-232 is selectable.*2: Connection to DH485 network possible via adaptor (1770-KF3).*3: Connection to DH485 requires a "Series-C" or later CPU. ("Series-B" and earlier models do not support
the DH485 protocol.)*4: A one-to-one connection requires a "Series-D" or later CPU. ("Series-C" and earlier models do not
support the DF1 half-duplex format.)
V
V
V
V
V
VV
@
@
@
V
VV
V
@
@
@
@
@
V
@
V
@
V
@
V
@
@
@@
@
V
V
V
V
�������������������������
V
V
@
V
@
V
@
@
@
@
@
@
@
@
@
V
@
V
@
V
V
V
@
@
@
@
@
@
Model nameManufacturerComputer link connection
RS-422 RS-232 RS-422 RS-232CPU direct connection
OMRON
KEYENCE
SHARP
TOSHIBA
Hitachi
Industrial
Equipment
Systems
Micro PLC
Small-sized
PLC
Large-sized
PLC
PROSEC
T series
V series
Large-sized
H series
H200 to 252
series
H series
board type
EH-150 series
FA500
FA-M3
SLC 500 series *2
MicroLogix 1000 series
(Digital CPU) *2
MicroLogix 1000 series
(Analogue CPU) *2*3*4
MicroLogix 1200 series *2
MicroLogix 1500 series *2
CPM1A
CPM1
CPM2A
CPM2C
C200H
C200HS
C200HX
C200HG
C200HE
CQM1
CQM1H
CS1H
CS1G
CS1D
CJ1H
CJ1G
CJ1M
C1000H
C2000H
CV500
CV1000
CV2000
CVM1
KV-700
KV-1000
JW-21CU
JW-31CUH
JW-50CUH
JW-22CU
JW-32CUH
JW-33CUH
JW-70CUH
JW-100CUH
JW-100CU
Z-512J
T2(PU224)
T2E
T2N
T3
T3H
model 3000(S3)
model 2000(S2)
H-302(CPU2-03H)
H-702(CPU2-07H)
H-1002(CPU2-10H)
H-2002(CPU2-20H)
H-4010(CPU3-40H)
H-300(CPU-03Ha)
H-700(CPU-07Ha)
H-2000(CPU-20Ha)
H-200(CPU-02H, CPE-02H)
H-250(CPU21-02H)
H-252(CPU22-02H)
H-252B(CPU22-02HB)
H-252C(CPU22-02HC)
H-252C(CPE22-02HC)
H-20DR
H-28DR
H-40DR
H-64DR
H-20DT
H-28DT
H-40DT
H-64DT
HL-40DR
HL-64DR
EH-CPU104
EH-CPU208
EH-CPU308
EH-CPU316
@
@
@
@
@
V
@
@
@
@
@
@
V
V
V
V
@
@
V
@
V
@
V
V
V
V
@
V
@
@
V
V
@
V
@
@
@
@
@
@
V
@
V
@
V
@
@
@
Model nameManufacturerComputer link connection
RS-422 RS-232 RS-422 RS-232CPU direct connection
Matsushita Electric Works
Yaskawa Electric
Yokogawa
Electric
Allen-Bradley
(Rockwell)
SIEMENS
FP0-C16CT
FP0-C32CT
FP1-C24C
FP1-C40C
FP2
FP2SH
FP3
FP5
FP10(S)
FP10SH
FP-M(C20TC)
FP-M(C32TC)
FP-·
GL120
GL130
GL60S
GL60H
GL70H
CP-9200SH
CP-9300MS
MP-920/930
MP-940
PROGIC-8
CP-9200(H)
FA500
F3SP05
F3SP08
F3SP10
F3SP20
F3SP30
F3FP36
F3SP21
F3SP25
F3SP35
F3SP28
F3SP38
F3SP53
F3SP58
F3SP59
SLC500-20
SLC500-30
SLC500-40
SLC5/01
SLC5/02
SLC5/03
SLC5/04
SLC5/05
1761-L10BWA
1761-L10BWB
1761-L16AWA
1761-L16BWA
1761-L16BWB
1761-L16BBB
1761-L32AWA
1761-L32BWA
1761-L32BWB
1761-L32BBB
1761-L32AAA
1761-L20AWA-5A
1761-L20BWA-5A
1761-L20BWB-5A
1762-L24BWA
1764-LSP
SIMATIC S7-200 series
SIMATIC S7-300 series
SIMATIC S7-400 series
*1
*1
*1
*1
*1
*1
*1
*1
Co
nn
ectable m
od
el list
C o n n e c t a b l e m o d e l l i s t
31
Other brand PLCs/motion controllers
[PLC/motion controller]Achieve maximum 115.2kbps high-speed communication with other brand PLCs via RS-232 communication. Having an RS-422 converter unit or serial communication unit on the GT15, can be performed RS-422 communication.The GT11 model is embedded with both an RS-422 and RS-422 interface as standard.
30
OMRONUpper-level link unit, communication unit, communication board
C200H-LK202-V1C500H-LK201-V1CQM1-SCB41CJ1W-SCU41CS1W-SCB41C200HW-COM03C200HW-COM06
C200H-LK201-V1C500H-LK201-V1CS1W-SCU21CS1W-SCB21CS1W-SCB41CJ1W-SCU41C200HW-COM02C200HW-COM05C200HW-COM06CQM1-CIF01CQM1-CIF02CQM1-SCB41CPM1-CIF01CPM2C-CN111CPM2C-CIF01-V1
RS-422Manufacturer RS-232
mModules that can be connected to other brand computer link module
mModules that can be connected to Mitsubishi CNC
Manufacturer Model name RS-422 RS-232
OMRON
YAMATAKE
RCK
Thermac NEO
In-Panel NEO
SDC
DMCH-PCP-J H-PCP-A,H-PCP-B
E5ANE5ENE5CNE5GNE5ZNSDC20/21SDC30/31SDC40A/40B/40GSDC15SDC25/26SDC35/36DMC10
MR-J2S-□AMR-J2S-□CPMR-J2M-P8AMR-J2M-□DUMR-J3-□A
@
@
@
@
@
@
@
@
@
@
@
@
V
V
RS-485V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (4-wire type)V (4-wire type)V (4-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type)V (2-wire type) @
V
V
V
V
V
V
V
V
V
V
V
V
V
V
RS-422Manufacturer RS-232
KEYENCE KV-L20RKV-L20
KV-L20RKV-L20
Hitachi Industrial Equipment SystemsIntelligent serial port module
Matsushita Electric WorksComputer communication unit
COMM-HCOMM-2H
JAMSC-120NOM27100JAMSC-IF612
COMM-HCOMM-2H
AFP2462AFP3462AFP5462
Yaskawa Electric Memo bus module
JAMSC-IF60JAMSC-IF61CP-217IF
LC02-0NF3LC11-2N
Yokogawa ElectricPersonal computer link module
LC01-0NLC02-0NF3LC01-1NF3LC11-1NF3LC11-1FF3LC12-1F
SHARP Link unit
JW-21CMJW-10CMZW-10CM
[Servo amplifier]
[Temperature controller]
Servo amplifiers Set parameters and display alarms when connected to Mitsubishi servo amplifiers.
CNC MELDAS C6/C64 monitoring and parameter settings can be performed.
Inverter Set parameters and display alarms when connected to Mitsubishi inverters.
Temperature controller Log data, set parameters, and display alarms when connected to temperature controllers.
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*2
*2
*2
*2
*2
*2
*2
*2
Manufacturer Model name RS-422 RS-232
MITSUBISHIFREQROL-S500/E500/A500/F500 FREQROL-A700/F700
V
V
@
@
Manufacturer Model name RS-422 RS-232
MITSUBISHI
MELSERVO-J2-Super series
MELSERVO-J2M series
MELSERVO-J3 series
V
V
V
V
V
V
V
V
V
V
[CNC]
[Inverter]
*1:Supported only by the GT15.*2:RS-232/RS-485 conversion adaptor is required.
SeriesConnection configuration
Modelname
Busconnection
CPUdirect
connection
Computer-link con-nection
MELSECNET/10
CC-Link(ID)
CC-Link(via G4)
Ethernet*1*1*2 *1*3
MELDASC6/C64
FCA C6FCA C64
@ V@VV@V*4 *4 *4*5
*1: Supported only by the GT15.*2: When MELSECNET/H is used in NET/10 Mode, the GOT terminal cannot be connected directly to a Remote
I/O station.*3: CC-Link (ID): Connected as CC-Link (intelligent device station).
This is a "Ver.1 intelligent device station" permitting monitoring by transient and cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used.
*4: Use NC system software version D0 or later.*5: Use NC system software version E0 or later.
MELDAS C6/C64 FCU6-EX879 FCU6-EX878
vFor MELSECNET/10 connection
SeriesOptical loop Coaxial bus
MELSECNET/H (NET/10 mode), MELSECNET/10 module
MELDAS C6/C64 FCU6-HR865
vFor CC-Link (ID) connectionSeries CC-Link unit
MELDAS C6/C64 FCU6-EX875
vFor Ethernet connectionSeries Ethernet unit
The GOT1000 series allows connection to Mitsubishi PLCs and a variety of other FA devices.
F
C o n n e c t i o n c o n f i g u r a t i o n
RS-232�cable
RS-422�cable
GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m
vFX series (FX1S, FX1N, FX2N)FX series (FX1S, FX1N, FX2N)(Function extension board (FX□N-232-BD) for RS-232)
(Function adaptor (FX2NC-232-ADP) for RS-232) *2
(Function adaptor (FX0N-232-ADP) for RS-232) *2
FX series (FX1S, FX1N, FX2N)(RS-422 CPU port)(Function extension board (FX□N-422-BD) for RS-422)
RS-232�cable
GT01-C□R2-9S30: 3m
GT01-C□R2-25P30: 3m
RS-232
RS-422
GT15
RS-232
RS-422
RS-422�cable
GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m
vFX series(FX1NC,FX2NC)FX series (FX1NC, FX2NC)(Function adaptor (FX2NC-232-ADP) for RS-232)
(Function adaptor (FX0N-232-ADP) for RS-232)
FX series(FX1NC,FX2NC)(RS-422 CPU port)
when using the function extension board or the function adaptor specified on the right.
when using function adaptor specified on the right
( when using RS-422 CPU port )2 units
Maximum number of GOTs connected
Maximum connection distance
1 unit
15m
when using the function extension board (FX□N-422-BD)
2 units
Maximum number of GOTs connected
Maximum connection distance
1 unit
30m
( when using RS-232 function adaptor )2 units
Maximum number of GOTs connected
Maximum connection distance
1 unit
30m
( when using RS-422 CPU port )2 units
Maximum number of GOTs connected
Maximum connection distance
1 unit
15m
GT01-C□R2-9S30: 3m
GT01-C□R2-25P30: 3m
RS-422
RS-422�cable
GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m
FX series (FX3UC, FX3CU)(RS-422 CPU port)(Function extension board (FX3U-422-BD) for RS-422)( when using RS-232 CPU port )3 units
Maximum number of GOTs connected
Maximum connection distance
2 units
30m
when using the CPU port and the function extension board specified on the right.
*2:A Function extension board is required.
RS-422
RS-422�cable
GT01-C□R4-8P10: 1m30: 3m100: 10m200: 20m300: 30m
vFX series(FX0S,FX0N)FX series(FX0S,FX0N)(RS-422 CPU port)
Maximum number of GOTs connected
Maximum connection distance
1 unit
30m
FX2N-32MR
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
POWERRUNBATT.VPROG.ECPU.E
FX2N-32MR
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
POWERRUNBATT.VPROG.ECPU.E
FX0N-232ADPPOWER
RD
SD
FX2NC-232ADP
FX2NC-16MT
FX0N-24MR
32 33
Co
nn
ection
con
figu
ration
Maximum connection distance
Maximum number of GOTs connected
Maximum connection distance
vQnA / ACPU / A series Motion controller CPU
QCPU Q series Motion Controller CPU MELSECNET/H remote I/O station (CPU port: RS-232)
QCPU Q series Motion Controller CPUMELSECNET/H remote I/O station (CPU port: RS-232)
GT01-C□R2-6P30:3m
RS-232 cable
1 unit
3m
FA-CNV□CBL*12402: 0.2m2405: 0.5m
RS-422�cable
RS-232
RS-422
GT01-C□R4-25P30: 3m100: 10m
200: 20m300: 30m
GT01-C□R4-25P30: 3m100: 10m200: 20m300: 30m
1 unit
30.5m
RS-232/422conversion cable
QnA/ACPU/A series Motion Controller CPU (CPU port: RS-422)
RS-422�cable
GT15
GT15
RS-422
GT15
Maximum number of GOTs connected
Maximum connection distance
1 unit
30m
*1:This item is developed by Mitsubishi Electric Engineering Company Limited and sold through your local sales office.
0123456789ABCDEF
0123456789ABCDEF
To achieve optimum performance, select one of the various connection configurations as well as the units to be connected, the distance, and the maximum number of GOT terminals. For connection configuration when using multi-channel function, refer to the "Notes for use" on page 55.
Embeddedin GOT
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
GT15-RS2T4-9P
Serial communication
unit
RS-422 converter
Embeddedin GOT
GT15-RS2T4-9P
RS-422converter
GT15-RS4-9S
or
Serial communication
unitGT15-RS4-9S
or
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
GT15
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
GT11
GT11
GT11
GT11
GT11
GT11
GT11
GT11
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
Fabricated by user when length exceeds 3m.
Fabricated by user when length exceeds 3m.
( )AnN,AnS(H),A1SJ(H)
QCPU (Q mode) Q series Motion Controller CPU
GT15-QC□BGT15-QC□BS
Bus connection unit
Bus connection unit
Bus connection unit
5 units
37m
Connectionconfiguration Connection cable Connected toMaximum number of GOTs connected
Maximum connection distance
Maximum number of GOTs connected
Maximum connection distance
Maximum number of GOTs connected
Maximum connection distance
Communication interface installed on GOT side
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
vQCPU (Q mode) / Q series Motion controller CPU
vQnA/ACPU
vQCPU / Q series Motion controller CPU
QnA/ACPUGT15-C□NBGT15-AC□BGT15-A1SC□BGT15-A1SC□NBGT15-C□EXSS-1*1
GT15-C□BSGT15-J2C□B
GT15-C□NBGT15-AC□BGT15-A370C□B-S1GT15-A370C□BGT15-A1SC□BGT15-C□EXSS-1*1
GT15-C□BS
when connected with QnACPU type/AnCPU type
when connected with A273UCPU/A273UHCPU(-S3)/A373UCPU(-S3): with extension base
when connected with A273UCPU/A273UHCPU(-S3)/A373UCPU(-S3): without extension base
when connected with A171SHCPUN/A172SHCPUN/A173UHCPU(-S1): with extension base
when connected with A171SHCPUN/A172SHCPUN/A173UHCPU(-S1): without extension base
3 units
36.6mwhen connected with QnASCPU type/AnSCPU type36m
2 unitsA0J2HCPU1 unit
( )A171SHCPUNA172SHCPUN
2 units
vA series Motion controller CPUA series Motion Controller CPU
3 units
36.6m
32.5m
33m
30m
MELSEC-Q/QnA/A/FX series can be connected via CPU direct connection at the lowest cost.CPU direct connection
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
vQCPU (Q mode) / QnACPU / Q series Motion controller CPU
Connects multiple GOTs easily via serial communication (connecting one or two GOTs with one computer link unit).Computer link connection
Refer to Bus connection on page 38 and following for details.
GT15
GT15
GT15
*1: See the external dimensions information (page 51 and following) for the GT15-C□EXSS-1 cable shape.*2: Use of the Ethernet download and Gateway function requires the GT15-QBus (2). Note that the GT15-75QBus (2) L cannot be used.*3: Use of the Ethernet download and Gateway function requires the GT15-ABus (2). Note that the GT15-75ABus (2) L cannot be used.
GT15-75QBUSL*2
GT15-75QBUS2L*2GT15-QBUS*2
GT15-QBUS2*2
0123456789ABCDEF
Touch switches achieves as quick response as pushbuttons.Bus connection
Mitsubishi PLC
GT15-75ABUSL*3
GT15-75ABUS2L*3GT15-ABUS*3
GT15-ABUS2*3
GT15-75ABUSL*3
GT15-75ABUS2L*3GT15-ABUS*3
GT15-ABUS2*3
RS-232
GT15
RS-232�cable
vFX series (FX3U, FX3UC)FX series (FX3U, FX3UC)(Function extension board (FX3U-232-BD) for RS-232)(Function adaptor (FX3U-232-ADP) for RS-232)*2
GT01-C□R2-9S30: 3m when using the function extension board or
the function adaptor specified on the right.( when using RS-422 CPU port )3 units
Maximum number of GOTs connected
Maximum connection distance
2 units
15m
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
Fabricated by user when length exceeds 3m.
To be fabricated by user. QCPU (Q mode) / QnASCPU type Q series Motion Controller MELSECNET/H remote I/O station
QnACPU type
1 unit
15m
Maximum connection distance
1 unit
15m
Maximum number of GOTs connected
Maximum connection distance
RS-232�cable
RS-232�cable
D-sub 9 pins (female) D-sub 9 pins (male)
To be fabricated by user.
D-sub 9 pins (female) D-sub 25 pins (male)
RS-232
( when QJ71C24N-R2 is used )2 units
AJ71UC24-S2
AJ71UC24-S2
0123456789ABCDEF
GT15
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
GT15
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
GT11
GT11
GT11
GT11
ERROR
RUN
BATT
POWER
0 31 2
0 31 2IN
OUT
4 75 6
4 75 6FX3U-16MFX3U
R
ERROR
RUN
BATT
POWER
0 31 2
0 31 2IN
OUT
4 75 6
4 75 6FX3U-16MFX3U
R
Serial communication unit
Serial communication unit
Bus connection
cable
Bus connection
cable
Bus connection
cable
( )
C o n n e c t i o n c o n f i g u r a t i o n
RS-422�cable
CC-Link dedicated cable
For details, refer to the "Connectable model list" on page 30.
26 units
Maximum connection distance
CC-Link dedicated cable
CC-Link communication
unit
GT15-75J61BT13-Z (For intelligent device station)
AJ61QBT11
05
9
4
8
3
7
2
6
108
F
7
E
6
D
5
C
4
B
3
A
2
9
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
CC-Link unit
QCPUQnA/ACPU (Master/local station)A series Motion Controller CPU
0123456789ABCDEF
(When transient transmitting suggested 5 or less GOTs)
Maximum connection distanceGT15-J71E71-100
100m
AJ61QBT11
05
9
4
8
3
7
2
6
108
F
7
E
6
D
5
C
4
B
3
A
2
9
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
Ethernet unit
QCPUQnA/ACPUA series Motion Controller CPU
0123456789ABCDEF
1 unit
Maximum connection distance AJ61QBT11
05
9
4
8
3
7
2
6
108
F
7
E
6
D
5
C
4
B
3
A
2
9
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
CC-Link unit
QCPU (Q mode)Q series Motion controller CPU (RS-232 CPU port)
0123456789ABCDEF
AJ65BT-G4-S3
10BASE-T cable100BASE-TX cable
GT01-C□R4-25P30 : 3m100: 10m200: 20m300: 30m
Ethernetcable
Ethernet communication
unit
Maximum segment length
Connection cable to other brand PLC*1
RS-422�cable
D-sub 9 pins (male)
Depending on the PLC CPU specifications to which the GOT is connected.
Compatible with the following other brand PLC CPUs· OMRON· KEYENCE· SHARP · TOSHIBA · Hitachi Industrial Equipment Systems · Matsushita Electric Works · YASKAWA Electric · YOKOGAWA Electric · Allen-Bradley (Rockwell Automation) · SIEMENS
Compatible with the following other brand PLC CPUs· OMRON· KEYENCE· SHARP · TOSHIBA · Hitachi Industrial Equipment Systems · YASKAWA Electric · YOKOGAWA Electric
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
D-sub 9 pins (female)
Connection cable to other brand PLC*1
1 unit
Maximum connection distance
Depending on the PLC CPU specifications to which the GOT is connected.
Maximum number of GOTs connected
1 unit
Maximum connection distance
RS-232cable
RS-422
RS-232
0123456789ABCDEF
POWER
0123456789ABCDEF
POWER
*1: GT11 can only monitor the master station.*2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed. For details, refer to the user's manual for the CC-Link master/local unit being used.
*1: This is a "Ver.1 intelligent device station". Monitoring is possible via transient or cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used.*2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed.
34 35
Co
nn
ection
con
figu
ration
D-sub 9 pins (male)
QCPU (Q mode) / QnASCPU type Q series Motion Controller CPUMELSECNET/H remote I/O station
QnACPU type
vQCPU (A mode) / ACPU / A series Motion controller CPUQCPU (A mode) / ACPU / A series Motion Controller CPU
15m
1 unit
Maximum number of GOTs connected
Maximum connection distance
To be fabricated by user.RS-232�cableD-sub 9 pins (female)
D-sub 9 pins (male)
Maximum number of GOTs connected
Maximum connection distance
To be fabricated by user.
500m
1 unit
Maximum number of GOTs connected
Maximum connection distance
RS-422�cable
D-sub 9 pins (male)
To be fabricated by user.RS-422�cable
1 unit
1200m 500m
Maximum number of GOTs connected
Maximum connection distance
1 unit
1200m 500mD-sub 9 pins (male)
RS-422�cable
GT01-C□R4-25P30: 3m100: 10m
Fabricated by user when length exceeds 30m.
RS-422
RS-422
RS-232
GT15
GT15
( when AJ71UC24 is used )
( when QJ71C24N-R4 is used )2 units
D-sub 9 pins (female)
D-sub 25 pins (male)
*1: MELSECNET/H is also used in NET/10 mode.*2: The maximum total extension length and distance between stations vary according to the number of stations and the cable type being used. For details, refer to the MELSECNET/H and MELSECNET/10 Reference Manuals.
*1: This item is developed by Mitsubishi Electric Engineering Company Limited and sold through your local sales office.
AJ71UC24-S2
0123456789ABCDEF
AJ71UC24-S2
AJ71UC24-S2
Fiber-optic cable 63 units
Maximum connection distance
MELSECNET/10communication unit
Fiber-opticcable
Coaxial cableCoaxialcable
GT15-75J71LP23-Z(Optical loop)GT15-75J71BR13-Z(Coaxial bus)
Maximum number of GOTs connected
31 units
Maximum connection distance
AJ61QBT11
05
9
4
8
3
7
2
6
108
F
7
E
6
D
5
C
4
B
3
A
2
9
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
Network unit
QCPU QnA/ACPU (Control station/normal station)/ A series Motion Controller CPU
0123456789ABCDEF
Opticalloop
Coaxialbus
*2With QSI optical cable, maximum distance between stations is
*2
1km
500m
200: 20m300: 30m
GT15
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
GT15
GT15
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
GT15
Embeddedin GOT
Embeddedin GOT
orSerial
communicationunit
GT15-RS2-9P
GT15
Embeddedin GOT
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
orConnection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Allows multiple GOTs to be used as remote control terminals. (Connectable as MELSECNET/10*1 normal stations.)MELSECNET/10 Connection (PC-to-PC Network)
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Supporting other brand PLC CPUConnection to other brand PLC
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Connects microcomputer board or personal computer to the GOTs.Microcomputer connection
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Connects CC-Link system as intelligent device station.*1CC-Link (ID) connection
Connectionconfiguration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Connectable to CC-Link by way of AJ65BT-G4-S3. *1CC-Link (via G4) connection
Machines on the production floor can be easily accessed from a remote location (Remote Maintenance) when GOT terminals are fitted with an Ethernet interface.Ethernet connection
To be fabricated by user.RS-422�cable
D-sub 9 pins (male)
Depending on the specifications of the host side personal computer, microcomputer board, PLC, etc.
Microcomputer board, personal computer, PLC, etc.
D-sub 9 pins (female)
To be fabricated by user. 1 unit
Maximum connection distance
Depending on the specifications of the host side personal computer, microcomputer board, PLC, etc.
Maximum number of GOTs connected
1 unit
Maximum connection distance
RS-232�cable
RS-422
GT15GT15-RS2T4-9P
RS-232
GT15
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
QX41
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
Serial communication
unit
RS-422converter
Embeddedin GOT
Embeddedin GOT
Embeddedin GOT
GT15-RS4-9S
or
orSerial
communicationunit
GT15-RS2-9P
Connectionconfiguration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Other brand PLC
Microcomputer
GT11
GT11
GT11
GT11
GT11
GT11
GT11
GT11
GT11
Serial communication unit
Serial communication unit
Computer link unit
( )when A1SJ71UC24-R4 or A1SJ71C24-R4 is used.
( )
With 5C-2V coaxial cable, maximum distance between stations is 500m( )
(For CC-Link dedicated cable at 156kbps: )
*2
1200m
Peripheral device connection unit for GPP function
( )1230m1200m
30m
: CC-Link dedicated cable 156Kbps
: RS-422 cable
+
In the following cases:
*2
128 units(Suggested less than 16 GOTs)
Maximum connection distance
Maximum number of GOTs connected
Maximum connection distance
MELDAS C6/C64 *1
MELDAS C6/C64 *1
To be fabricated by user.RS-232cable
1 unit
3m
RS-422�cable
RS-232
RS-422
GT01-C□R4-25P30: 3m100: 10m200: 20m300: 30m
1 unit
30.5m
GT15
GT15
Embedded in GOT
Embedded in GOT
Embedded in GOT
orSerial
communicationunit
GT15-RS2-9P
GT15-RS2T4-9P
Serial communication
unit
RS-422converter
GT15-RS4-9S
or
Maximum connection distance
Maximum number of GOTs connected
1 unit
Maximum connection distance
RS-485
GT15
RS-485
GT15
Embedded in GOT
GT15-RS4-9S
Serial communication
unit
Serial communication
unit
GT15-RS4-TE
or
GT15-RS4-TE
Serial communication
unit
Temperature controller· YAMATAKE
C o n n e c t i o n c o n f i g u r a t i o n
RS-422�cable
Maximum connection distance
Maximum number of GOTs connected
1 unit
Maximum connection distance
RS-232cable
RS-422
GT15
RS-232
GT15
D-sub 9 pins (male)
Terminal block
Terminal block
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
Depending on the PLC CPU specifications to which the GOT is connected.
D-sub 9 pins (female)
D-sub 9 pins (male)
FX2N-32MR
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
POWERRUNBATT.VPROG.ECPU.E
RS-232 1 RS-422 2
Connected PLCs RS-232 cable 1 RS-422 cable 2
30m15m
When the first device is connected via RS-232 connection
FX2N-32MR
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
0 1 2 3 4 5 6 7
10 11 12 13 14 15 16 17IN
POWERRUNBATT.VPROG.ECPU.E
RS-232 2RS-422 1
15m30m
When the first device is connected via RS-422 connection
QCPUQJ71C24, QJ71C24N, QJ71C24-R2, QJ71C24N-R4FX1S+FX1N-232BD / FX1N+FX1N-232BD or FX1S+FX2NC-232ADP / FX1N+FX2NC-232ADP*2FX2N+FX2N-232BD or FX2N+FX2NC-232ADP*2FX1NC+FX2NC-232ADP / FX2NC+FX2NC-232ADPFX3U+FX3U-232BD or FX3U+FX3U-232ADP*2FX3UC+FX3U-232BD or FX3UC+FX3U-232ADP*2
GT01-C30R2-6P (3m)Fabricated by user.
GT01-C30R2-9S (3m)Fabricated by user.
Connected PLCs RS-422 cable 1 RS-232 cable 2
A/QnACPU
QJ71C24, QJ71C24N, QJ71C24N-R4FX1S/FX1NCPU or FX1S+FX1N-422BD/FX1N+FX1N-422BDFX2NCPU or FX2N+FX2N-422BDFX1NC / FX2NCCPUFX3UCPU or FX3U+FX3U-422BDFX3UCCPU or FX3UC+FX3U-422BD
GT01-C30R4-25P (3m)GT01-C100R4-25P (10m)GT01-C200R4-25P (20m)GT01-C300R4-25P (30m)Fabricated by user.GT01-C10R4-8P (1m)GT01-C30R4-8P (3m)GT01-C100R4-8P (10m)GT01-C200R4-8P (20m)GT01-C300R4-8P (30m)
GT01-C30R2-9S (3m)
Servo amplifierMELSERVO-J2-Super seriesMELSERVO-J2M seriesMELSERVO-J3 series
Servo amplifierMELSERVO-J2-Super seriesMELSERVO-J2M seriesMELSERVO-J3 series
30m
15m
500m
500m
L1 L2 L3
U V W
OPEN
36 37
Co
nn
ection
con
figu
ration
RS-422�cable
InverterFREQROL500 seriesFREQROL700 series
*1
Maximum connection distanceRS-422
GT15-RS2T4-9PGT15
Serial communication
unit
RS-422converter
GT15-RS2T4-9P
RS-422converter
Embedded in GOT
Embedded in GOT
Embedded in GOT
GT15-RS4-9S
or
Serial communication
unit
GT15-RS4-9S
or
Serial communication
unit
GT15-RS2-9P
or
RS-422�cable
1 unit
Maximum number of GOTs connected
1 unit
Maximum connection distance
Maximum number of GOTs connected
1 unit
Maximum connection distance
RS-232cable
RS-422
GT15GT15-RS2T4-9P
RS-232
GT15
Serial communication
unit
RS-422converter
Embedded in GOT
Embedded in GOT
Embedded in GOT
GT15-RS4-9S
or
orSerial
communicationunit
GT15-RS2-9P
Temperature controller· OMRON· YAMATAKE· RKC
Temperature controller· OMRON· YAMATAKE· RKC
Temperature controller· RKC
FR-DU04 CONTROL PANELHz
MON EXT PU
AV
REV FWD
D-sub 9 pins (male)
D-sub 9 pins (female)
D-sub 9 pins (male)
CPU direct connectionTemperature controller connection
CNCTemperature controller
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT sideConnection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
1 unit
Inverter connection
Inverter
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
1 unit
Servo amplifier connection
Servo amplifier
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
26 units
Maximum connection distance
CC-Link dedicated cable
CC-Link communication
unit
GT15-75J61BT13-Z (For intelligent device station)
MELDAS C6/C64 *3
(When transient transmitting suggested 5 or less GOTs)
*1: Use NC system software version D0 or later.
GT15
GT15
*1: MELSECNET/H is also used in NET/10 mode.*2: The maximum total extension length and distance between stations vary according to the number of stations and the cable type being used. For details, refer to the MELDAS C6/C64 Reference Manuals.*3: Use NC system software version E0 or later.
*1: Use NC system software version D0 or later.
*1: The number of connected temperature controllers, the maximum connection distance, and the cable and devices vary according to the temperature controller type. For details, refer to the GOT1000 Series Connection Manual.
*1: The cable and devices vary according to the inverter type. For details, refer to the GOT1000 Series Connection Manual.
*1: The number of connected servo units, the maximum connection distance, and the cable and devices vary according to the servo type. For details, refer to the GOT1000 Series Connection Manual.
Fiber-optic cable 63 unitsMaximum connection distance
MELSECNET/10communication unit
Fiber-opticcable
Coaxial cableCoaxialcable
GT15-75J71LP23-Z(Optical loop)GT15-75J71BR13-Z(Coaxial bus)
Maximum number of GOTs connected
31 unitsMaximum connection distance
MELDAS C6/C64 *3
Opticalloop
Coaxialbus
GT15
Allows multiple GOTs to be used as remote control terminals. (Connectable as MELSECNET/10*1 normal stations.)
MELDAS C6/C64 monitoring and parameter settings can be performed.Log data, set parameters, and display alarms when connected to temperature controllers.
MELSECNET/10 Connection (PC-to-PC Network)
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Connects CC-Link system as intelligent device station.*1CC-Link (ID) connection
Connection configuration Connection cable Connected toMaximum number of GOTs connectedCommunication interface installed on GOT side
Machines on the production floor can be easily accessed from a remote location (Remote Maintenance) when GOT terminals are fitted with an Ethernet interface.Ethernet connection
F311 cable
128 units
Maximum connection distance
GT15-J71E71-100
100m
MELDAS C6/C64 *110BASE-T cable100BASE-TX cable
Ethernetcable
Ethernet communication
unit
(Suggested less than 16 GOTs)
Maximum segment length
GT15
Up to 32 axes can be controlled when multiple servo amplifiers are connected in multi-drop connection, with capabilities for parameter setting and alarm display.
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
L1 L2 L3
U V W
OPEN
GT11
GT11
GT11
GT11
GT11
GT11
GT11
*1
*1
*2
*2
With QSI optical cable, maximum distance between stations is 1km( )
500mWith 5C-2V coaxial cable, maximum distance between stations is( )
(For CC-Link dedicated cable at 156kbps: )
*2
1200m
Multiple unit connections (GT11) 2unitsM
axim
um number of G
OTs
When connected directly to Mitsubishi PLC and CPU
• The transparent function is not available when multiple units are connected.• Multiple units cannot be connected using the USB interface.
RS-485(4-wire type)
cable
RS-485(2-wire type)
cable
Up to 10 inverters can be connected in multi-drop connection with capabilities for parameter setting and alarm display.
When connecting inverters in multi-drop connection: Max. extension length is ( )
When connecting MELSERVO-J2 in multi-drop connection: Max. extension length is
Extension unit
Extension unit
Extension unit
*1: Handy GOT can only be connected as the second device.
*1: Handy GOT can only be connected as the second device.
*2: Function extension board is required.
*1: This is a "Ver.1 intelligent device station". Monitoring is possible via transient or cyclic communication. Cycliccommunication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the MELDAS C6/C64 being used.*2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed.*3: Use NC system software version D0 or later.
When using MELSERVO-J2-Super
[4-wire type]
[2-wire type]
GOT 1
GOT 1
When connected with QCPU (Q mode) Q series Motion controller CPU For connectable CPU models, refer to "Connectable mode list" on page 28.
5units
Max
imum
num
ber of GOTs connected
Number of GOTs
C o n n e c t i o n d i s t a n c e
GOT connection conditions System configuration
0m 13.2m 37m
Cable 1 GOT 1 Middle GOT 2 4~~ Last GOT 2 5~~
Cable 1
Cable 1
GOT 1
GOT 1
Cable 2 Cable 3
GT15-QC B GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2
GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2
GT15-75QBUS2LGT15-QBUS2
GT15-75QBUS2LGT15-QBUS2
06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m
GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m
GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
GT15-QC BS150 : 15m200 : 20m
GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m
GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
GT15-QC BS150 : 15m200 : 20m
GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
GT15-QC BS150 : 15m200 : 20m250 : 25m300 : 30m350 : 35m
GT15-QC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m100: 10m
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
Bus connection unitGOT main unit Bus connection unitGOT main unit Bus connection unitGOT main unit
1 unit
2 to 5 units
Within13.2m
More than13.2m
Within13.2m
More than13.2m
PLCMain base
PLCMain base
PLCExtension base
*1
*1
*5
*3
*3
*3
*2 *4 *4 *4
Cable 1
Cable 1
Cable 2
Cable 2
Cable 3
Cable 3
PLCExtension base
*2
*2
Max. 37m
Max. 13.2m
Max. 13.2mMax. 37m
Max. 37m
PLCMain base
PLCMain base
PLCExtension base
Middle GOT 2 4~~ Last GOT 2 5~~
Middle GOT 2 4~~ Last GOT 2 5~~PLCExtension base
A9GT-QCNB
A9GT-QCNB
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75QBUS2LGT15-QBUS2
GT15-75QBUS2LGT15-QBUS2
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2
GT15-75QBUSL�GT15-75QBUS2LGT15-QBUSGT15-QBUS2
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
Bus extension connector box
Bus extension connector box
Bus extension connector box
*1: Includes the extension cable length (between base units) when an extension base unit is used. For cable details between main base and extension bese, refer to the MELSEC-Q catalog (L (NA) 08033E-A).
*2: A bus extension connector box is required if the first GOT is installed at a distance of 13.2m or more. If an extension base unit is not being used, install the bus extension connector box at the main base unit.
If an extension base unit is being used, install the bus extension connector box at the extension base unit of the stage that precedes the GOT. (When connected to a Q00JCPU, the box installation at the
main base unit is not possible. In this case, install it at the extension base unit.)
*3: Select cables whose total cable length is 37m or less from the PLC's main base unit to the last GOT.
*4: How to read cable type names, for example, QC B 06: 0.6m is GT15-QC06B.
*5: When 3 or more GOTs are connected, the following restrictions may be applied, depending on the total cable length: The PLC and all GOTs must have the same power supply and must be switched ON and
OFF simultaneously
Number of GOTs
2 or less
3
4
5
○○○○
○○○#
○###
Within 15m Within 20m
○○##
Within 25mTotal cable length
Within 37m
Bus connection is one of the simplest methods to connect one or even multiple GOT's using extension connectors of the base unit. This
connection method provides high performance as well as the fastest response time to Mitsubishi controllers. This solution allows multiple
GOTs terminals to be located when computer link (C24) is not desired. Refer to Notes for bus connection on page 46.
○: Restriction not applied #: Restriction applied
B u s c o n n e c t i o n 1
38 39
Bu
s con
nectio
n
Installation distance of the first unit
from main base *1
B u s c o n n e c t i o n 2
GOT 1
GOT 1
GOT 1 GOT 2
When connected with QnACPU type AnCPU typeFor connectable CPU models, refer to "Connectable mode list" on page 28.
Number of GOTs
GOT connection condition
0m 6.6m 36.6m
Cable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3
GT15-C NB GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
12 : 1.2m30 : 3m50 : 5m
GT15-C NB12 : 1.2m30 : 3m50 : 5m
GT15-C NB12 : 1.2m30 : 3m50 : 5m
GT15-C EXSS-1100 : 10m200 : 20m300 : 30m
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
Cable 0
GT15-AC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m
GT15-AC B06 : 0.6m12 : 1.2m30 : 3m50 : 5m
GOT main unit GOT main unit GOT main unit
1 unit
2 units
3 units
Within6.6m
More than6.6m
Within6.6m
Within6.6m
More than6.6m
Cable 1
Cable 0
Cable 1
Max. 6.6m
Max. 6.6m
Max. 36.6m
Max. 30m
Max. 6.6m
Max. 36.6m
Max. 30m
A7GT-CNB
A7GT-CNB
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m300 : 30m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
Bus connectorconversion box
Bus connectorconversion box
Bus connectorconversion box
*1: Includes the extension cable length (between base units) when an extension base unit is used.
For the cables between base unit and extension base unit, refer to the MELSEC-QnA/A catalog (L-174-0-C5177-B NA-0109).
*2: A bus connector conversion box is required if the first GOT is installed at a distance of 6.6m or more.
*3: Select cables so that the total cable length is 36.6m from the PLC's main base unit to the last GOT.
*4: GT15-C EXSS-1:
• Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m).
• Calculate cable lengths as follows:
GT15-C100EXSS-1: 10m
GT15-C200EXSS-1: 20m
GT15-C300EXSS-1: 30m
*5: Cable length can be read from cable model name. For example, "GT15-AC06B" is 0.6m long.
*6: Select cables so that the total cable length does not exceed 30m.
PLCMain base
PLCExtension base
PLCMain base
PLCExtension base
PLCMain base
PLCExtension base
PLCMain base
PLCExtension base
PLCMain base
PLCExtension base
AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
*1
*4
GT15-C EXSS-1100 : 10m200 : 20m
*4
*5 *5 *5 *5
Cable 1
*1
*3
*1
*3
*1
*3
*1 *6
*2
*2
Cable 2
GOT 1
Max. 6.6m
Max. 36.6m
Max. 30m
Cable 0 Cable 1 Cable 2
GOT 2
GOT 2
Max. 6.6m
Max. 36.6m
Max. 30m
Cable 1 Cable 2 Cable 3
GOT 1 GOT 3
C o n n e c t i o n d i s t a n c e
System configuration
AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
AX10A4UCPUA62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11 AX10A62P AX10 AX10 AX10 AY11 AY11 AJ71BR11 AJ71BR11
Max
imum
num
ber of GOTs connected
When QnA, AnU, or AnA is connected
Max
imum
num
ber of GOTs connected
When CPUs other than thatshown at left is connected
Bus connection unit Bus connection unit Bus connection unit
40 41
Bu
s con
nectio
n
3units
2units
Installation distance of the first unit
from main base *1
For connectable CPU models, refer to "Connectable mode list" on page 28.
Number of GOTs
C o n n e c t i o n d i s t a n c e
GOT connection conditions System configuration
0m 5m 35m30m
Cable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3
GT15-A1SC B GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
07 : 0.7m12 : 1.2m30 : 3m50 : 5m
GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m
GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m
GT15-C EXSS-1100 : 10m200 : 20m300 : 30m
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
Cable 0
GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m
GOT main unit GOT main unit GOT main unit
1 unit
2 units
3 units
Within5 m
More than 5 mWithin 35 m
Within5 m
Within5 m
More than5 m
A7GT-CNB
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m300 : 30m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-75ABUS2LGT15-ABUS2
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUS2LGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
Bus connectorconversion box
Bus connectorconversion box
Bus connectorconversion box
*1: A bus connector conversion box is required if only one GOT is connected at a distance of 30m or more.
*2: Select cables so that the total cable length is 35m or less from the PLC's main base unit to the last GOT.
*3: Select cables so that the total cable length does not exceed 30m.
*4: GT15-C EXSS-1:• Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m).• Calculate cable lengths as follows: GT15-C100EXSS-1 (10m), GT15-C200EXSS-1 (20m), GT15-C300EXSS-1 (30m).
*5: Cable length can be read from cable model name. For example, "GT15-A1SC NB" is 0.45m long.
*4
GT15-C EXSS-1100 : 10m200 : 20m300 : 30m
*4
GT15-C EXSS-1100 : 10m200 : 20m
*4
*5 *5 *5 *5*1
GOT 2
Max. 5m
Max. 5m
Max. 5mMax. 35m
Max. 30m
Max. 30m
Cable 1 Cable 2
GOT 1
Cable 1
GOT 1
GOT 1
Cable 1
Cable 0 Cable 1
Cable 3
GOT 1 GOT 3
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUNSTOP
RESET
PLCMain base
PLCMain base
PLCMain base
PLCMain base
PLCMain base
PLCMain base
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUNSTOP
RESET
*1
*2
*2
*3
*3
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUNSTOP
RESET
GT15-75ABUS2LGT15-ABUS2
GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m
A7GT-CNB 15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-C EXSS-1100 : 10m200 : 20m
*4
Max. 5mMax. 35m
GOT 2
Cable 0 Cable 1 Cable 2
PLCMain base
*1A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUNSTOP
RESET
GOT 1
Max. 5mMax. 35m
Max. 35m
Max. 30m
Max. 30m
Max. 30m
Max. 30m
GOT 2
Cable 1 Cable 2
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUNSTOP
RESET
GOT 1
GOT 2
Cable 1 Cable 2
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUNSTOP
RESET
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUNSTOP
RESET
GOT 1
Without extension base unit
Bus connection unit Bus connection unit Bus connection unit
More than 5 mWithin 35 m
More than 5 mWithin 35 m
*3
B u s c o n n e c t i o n 3
42 43
Bu
s con
nectio
n
Max
imum
num
ber of GOTs connected
When QnAS or A2US(H) is connected
Max
imum
num
ber of GOTs connected
When A1SJ(H) or AnS(H) CPU is connected
3units
2unitsWhen connected with QnASCPU type AnSCPU type
Installation distance of the first unit
from main base
B u s c o n n e c t i o n 4
0m 6m 36m
For connectable CPU models, refer to "Connectable mode list" on page 28.
Installation distance of the first unit
from main base
Number of GOTs
C o n n e c t i o n d i s t a n c e
GOT connection conditions System configurationCable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3
GT15-A1SC B GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUS2LGT15-ABUS2
07 : 0.7m12 : 1.2m30 : 3m50 : 5m
GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m
GT15-A1SC B07 : 0.7m12 : 1.2m30 : 3m50 : 5m
GT15-C EXSS-1100 : 10m200 : 20m300 : 30m
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
Cable 0
GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m
GOT main unit GOT main unit GOT main unit
Within6 m
Within6 m
Within6 m
More than6 m
More than6 m A7GT-CNB
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m300 : 30m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
GT15-75ABUS2LGT15-ABUS2
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
GT15-C BS07 : 0.7m12 : 1.2m30 : 3m50 : 5m100 : 10m200 : 20m
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-75ABUS2LGT15-ABUS2
GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
Bus connectorconversion box
Bus connectorconversion box
Bus connectorconversion box
*1: Includes the extension cable length (between base units).For "main base unit ⇔ extension base unit" cable details, refer to the MELSEC-QnA/A catalog (L-174-0-C5177-B NA-0109).
*2: A bus connector conversion box is required if the first GOT is installed at a distance of 30m or more.*3: Select cables so that the total cable length is 36m or less from the PLC to the last GOT.
*4: GT15-C EXSS-1:• Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m).• Calculate cable lengths as follows: GT15-C100EXSS-1 (10m), GT15-C200EXSS-1 (20m),
GT15-C300EXSS-1 (30m).
*4
GT15-C EXSS-1100 : 10m200 : 20m300 : 30m
*4
GT15-C EXSS-1100 : 10m200 : 20m
*4
*5 *5 *5 *5*2
Max. 6m
Max. 6m
Max. 36m
GOT 1
Cable 1
GOT 1
Cable 0 Cable 1
POWER
A1SP60A1S62P
POWER
PLCExtension base
PLCMain base
POWER
A1SP60A1S62P
POWER
PLCExtension base
PLCMain base
POWER
A1SP60A1S62P
POWER
PLCExtension base
PLCMain base
POWER
A1SP60A1S62P
POWER
PLCExtension base
PLCMain base
POWER
A1SP60A1S62P
POWER
PLCExtension base
PLCMain base
POWER
A1SP60A1S62P
POWER
PLCExtension base
PLCMain base
GOT 1
Cable 1
*2
*1
*1
*1
*1
*1*3
Max. 36m *1*3
GT15-75ABUS2LGT15-ABUS2
GT15-A1SC NB05 : 0.45m07 : 0.7m30 : 3m50 : 5m
A7GT-CNB 15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
GT15-C EXSS-1100 : 10m200 : 20m
*4
Max. 6m
GOT 2GOT 1
Cable 0 Cable 1 Cable 2
POWER
A1SP60A1S62P
POWER
PLCExtension base
PLCMain base
*2
*1
Max. 36m *1
Max. 6m
GOT 2
Cable 1
Cable 1
Cable 2
Max. 36m *1*3
GOT 1
Max. 6m Max. 30m
Max. 30m
Max. 30m
Max. 30m
Max. 30m
Max. 30m
GOT 3
Cable 1 Cable 2 Cable 3
Max. 36m
*6
*6
GOT 2GOT 1
GOT 2
Cable 2
Max. 36m *1*3
GOT 1
Bus connection unit Bus connection unit Bus connection unit
*5: Cable length can be read from cable model name. For example, "GT15-A1SC NB" is 0.45m long. *6: Select cables so that the total cable length does not exceed 30m.
1 unit
2 units
3 units
44 45
Bu
s con
nectio
n
When connected with QnASCPU type AnSCPU type With extension base unit
Max
imum
num
ber of GOTs connected
When QnAS or A2US(H) is connected
Max
imum
num
ber of GOTs connected
When A1SJ(H) or AnS(H) CPU is connected
3units
2units
For connectable CPU models, refer to "Connectable mode list" on page 28.
Number of GOTs
C o n n e c t i o n d i s t a n c e
GOT connection conditions System configuration
0m 1m
Cable 1 GOT 1 GOT 2 GOT 3Cable 2 Cable 3
GT15-J2C10B GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2
Cable Power supply unit0
GOT main unit GOT main unit GOT main unit
1 unit Within1 m
*2 *2*1
*1
Max. 1m
Max. 6m
GOT 1
Cable 1
Power supply unit
Cable 0
PLCA0J2CM
03: 0.3m
(for horizontal installation)
06: 0.55m
(for vertical installation)
10: 1m
(for extension)
20: 2m
(for extension)
A0J2-PW
*1: The power supply unit is required for connecting GOT.
*2: Cable length can be read from cable model name. For example, "GT15-J2C10NB" is 1m long.
For details regarding connection to an A series motion controller, refer to the "GOT1000 series Connection Manual" (SH (NA)-080532ENG).
15" type
12.1" type
10.4" type
10.4" type
8.4" type
8.4" type
GT1595
GT1585
GT1575
GT1572
GT1565
GT1562
Bus connection unit Bus connection unit Bus connection unit
10 : 1m
Q38Bmain base unit
Q68B extension base unit
QA1S68B extension base unit
GOT
Level of extension base unit
Connection method
231
Number of GOTs
1 unit2 units3 units4 units5 units
○○○○○
○○○○#
○○###
Within 15m Within 15 to 20m
○○○##
Within 20 to 25mTotal cable length
Within 25 to 37m
Connection target CPU Number of GOTs that can be connected
Total Permissible GOT + Intelligent Function Unit*1 Connections
QCPU (Q mode), motion controller CPU (Q series)
QCPU (A mode)QnACPU
ACPU
Motion controller CPU (A series)
*1: This applies to the following intelligent function unit types: AD51 (S3), AD51H (S3), AD51FD (S3), AD57G (S3), AJ71C21 (S1), AJ71C22 (S1), AJ71C23, AJ71C24 (S3/S6/S8), AJ71UC24, AJ71E71 (-S3), AJ71E71N-B2/B5/T/B5T, AJ71E71N3-T, AJ61BT11 (only in intelligent mode), A1SJ71C24 (-R2/PRF/R4), A1SJ71UC24 (-R2/PRF/R4), A1SJ71E71-B2/B5 (-S3), A1SJ71E71N-B2/B5/T/B5T, A1SJ71E71N3-T, A1SD51S, A1SJ61BT11 (only in intelligent mode)*2: Only the A1SD51S intelligent function unit can be connected to the QCPU (Q mode).
AnUCPU,AnACPU,A2US(H)CPUAnNCPU,AnS(H)CPU,A1SJ(H)CPUA0J2HCPUA1FXCPUA273UCPU,A273UHCPU(-S3),A373UCPU(-S3),A173UHCPU(-S1)A171SHCPUN,A172SHCPUN
Max. 5 units
Connection prohibitedMax. 3 unitsMax. 3 unitsMax. 2 unitsMax. 1 unit
Connection prohibited
Max. 3 units
Max. 2 units
5 GOTs + 6 intelligent function units*2
1Total 6 unitsTotal 6 unitsTotal 2 unitsTotal 2 units
1Total 6 units
Total 2 units
Connection target CPU
A1MCPU/A2USCPU(-S1)A2MCPU/Q2ACPUA3MCPU/A4MCPUQ3ACPU/Q4ACPUA0J2HCPU
Max. number of theextension base units
1�3�7�7�1
Use is prohibited
0�0
Communication interface settingSlot No.
2�4
No. of Extension Stages
○: Restriction does not apply.
#: The PLC and all GOTs must have the same power supply, and must all switch ON and OFF simultaneously.
Connection target CPU Number of GOTs Total current consumption
When using Q CPU (Q mode)
For other than QCPU (Q mode) connections
5 units4 units3 units2 units1 unit3 units2 units1 unit
2200mA1760mA1320mA880mA440mA360mA240mA120mA
46 47
Bu
s con
nectio
n
"Number of GOT extension stages" and "slot No." settings
When connected with A0J2HCPU
Max
imum
num
ber of GOTs connected
1unit
Installation distance of the first unit
from main base
B u s c o n n e c t i o n 5
P r e c a u t i o n s
1. Controller and recognition of GOTWhen GOT uses a bus, the CPU recognizes GOT as follows:• QCPU (Q mode) : Intelligent function unit with 16 I/O points.• Other than QCPU (Q mode): Intelligent function unit with 32 I/O points.
2. I/O assignment(1) For connection to the QCPU (Q mode)
Install 1 extension stage (16 points x 10 slots) for a GOT connection. (GOT cannot be assigned to a vacant I/O slot at the main base or any extension base.)Note By setting I/O slots that are not used for GOT as vacant (0 point), "16 points x 1
vacant slot" I/O numbers can be used for other devices.(This setting is specified in the GX Developer's [PLC parameter setting] - [I/O assignment setting].)
Reference See the "Precautions" section, item 9 (For Q mode connection).
(2) For other PLCs connectionAssign the GOT to a vacant I/O slot at the extension base.If there is no extension base, or if the extension base has no vacant slots, install another extension stage, and assign GOT to an I/O slot there. (GOT cannot be assigned to a main base I/O slot.)RReference See the "Precautions" section, item 10. For connection to QnA(S)CPU type
and An(S)CPU type.
1. At GOT power ON(1) System construction
While PLC CPU is in reset status until the GOT is started, sequence program will not starts. It is not possible to construct a system in which the sequence program turns the GOT power ON.
(2) Time period from GOT power ON to PLC run statusA PLC run starts approximately 10 seconds after the GOT starts up following a GOT power ON. When installing a new GOT in an existing system, or when replacing an existing GOT, the system timing should be adjusted to allow for this 10-second PLC startup delay.
(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection)Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"
(4) Power ON order when connected to a Q4ARCPU redundant systemReference See item 13. (2) "Power ON order for GOT and Q4ARCPU redundant system"
(5) GOT and PLC power ON order in systems other than those described in items (3) and (4) aboveThe system can be started regardless of whether the GOT power or the PLC power is turned ON first. There is no specified power ON order for GOT and the PLC. However, if a GOT→ PLC power ON order is used, operation occurs as follows.A system alarm (No.402: time-out error) occurs if the PLC is OFF when the GOT power is turned ON. GOT automatically begins monitoring after the PLC CPU is turned ON. Use the system information to reset the alarm.
2. At GOT restarts (OFF→ON)(1) GOT restart (OFF→ON) precaution
Do not restart GOT (OFF→ON) while the PLC power is ON. Before restarting GOT (OFF→ON), always be sure to turn the PLC power OFF. Note GOT1000 series automatic reboot operation
Because GOT1000 series automatically reboot at the conditions of OS installation and Utility setting changes, there is no need for a GOT restart (OFF→ON).• When an OS installation occurs from GT Designer2 or from the CF card.• When the utility setting content is changed.
(2) When GOT power is turned OFF before the user created screens are displayed on GOTCommunication may stop if the GOT power is turned OFF before the user created screens are displayed.If this occurs, restart the PLC CPU and GOT.
(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection)Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"
3. The GOT's reset switchThe reset switch on the GOT is disabled when using a bus connection.
4. At PLC power OFF or reset(1) When a PLC power OFF or reset occurs during monitoring
A system alarm (No.402: time-out error) occurs if a PLC power OFF or reset occurs during monitoring. GOT automatically resumes monitoring when a PLC CPU recovery occurs. Use the system information to reset the alarm.
(2) When a PLC CPU power OFF or reset occurs before the user created screens are displayed on GOTCommunication may stop if a PLC CPU power OFF or reset occurs before the user created screens are displayed on GOT. If this occurs, restart the PLC CPU and GOT.
(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection)
Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"
5. GOT connection positionThe GOT must always be connected to the last extension of a system. GOT cannot be connected between stages.
6. When GOT is connected to a PLC CPU via bus connection without having installed a communication driverA PLC CPU reset status occurs if GOT is connected to a PLC CPU via bus connection without having installed (at GOT) the basic function OS and a communication driver for the bus connection (communication with the PLC CPU using GX Developer, etc., is disabled). If the above occurs, disconnect GOT's bus connection cable to clear the PLC CPU's reset status.
7. System designWhen the GOT power is turned OFF, the current consumption values shown below are supplied to GOT from the PLC CPU side (power supply unit at main base unit). (GOT operation is disabled when the GOT power is OFF.) Be sure to design the system so that the
"5VDC current consumption of the unit installed at the main base unit" and the "GOT current consumption" total value does not exceed the 5VDC rated output of the power supply unit being used.
8. When assigning GOT input/output signalsDo not use a sequence program, etc., in an attempt to use input/output signals (assigned to the PLC CPU) to the GOT system. If this is attempted, GOT operation cannot be guaranteed.
9. When using QCPU (Q mode)(1) Total cable length restriction when connecting multiple GOTs
The following restrictions apply when 3 or more GOTs are connected.�
(2) When using Q00JCPUThe bus extension connector box can be installed only at an extension base unit. (It cannot be installed at the main base unit.)
(3) When using Q00J/Q00/Q01CPUWhen connected to Q00JCPU by a bus connection, the number of extension stages (including GOT) must not exceed 2.When connected to Q00CPU, Q01CPU by a bus connection, the number of extension stages (including GOT) must not exceed 4.
(4) When using the QA1S6MB type extension base unitAlthough GOTs can be connected to the last stages of all extension base units, the "number of GOT extension stages" setting must be assigned at the end of the QMMB extension base units.The "number of extension stages" for the QA1S6MB extension base unit is assigned at the last stage of the "number of GOT extension stages".
10. For connection to the QnA(S)CPU and An(S)CPU types(1) For connection to the QnASCPU and AnSCPU types
GOT can be connected only at one of the main base unit's extension connectors. (Concurrent GOT connections at both the extension connectors is not permitted.)
(2) For Q4A(R)CPU, Q3ACPU, A3MCPU, and A4UCPUA vacant I/O slot is required within the "maximum number of extension stages" range.
(3) For A0J2HCPUAssign GOT to I/O slots 0 to 3 at the first extension stage.
(4) For CPUs other than items (2) and (3) aboveEven if the maximum number of extension stages are being used, and there are no vacant slots, a GOT can be connected by using the following communication interface settings, provided that there are 32 or more vacant I/O points.
11. When multiple GOTs are connected(1) Composite GOT system
GOTs other than the GOT1000 Series cannot be used together with GOT1000 series.
(2) GOT quantity restrictionThe number of GOTs that can be connected is limited according to the connection target CPU and number of special function units which are installed.
12. When using the PLC CPU in a direct formatNote that a vacant I/O slot's input "x" input cannot be used when a direct I/O control mode is used for the connection target PLC CPU, with a 5m extension cable (GT15-AC50B, GT15-A1SC50NB), and with the first GOT connected to the main or extension base unit. This restriction does not apply when a "refresh" I/O control mode is used. At PLC CPU's equipped with an I/O control mode selector switch, set the switch to the "refresh" format.Note Examples of a vacant I/O slot's "x" input usage
• When input "x" is assigned at the MELSECNET/10 network.• When a vacant I/O slot's input "x" is turned ON/OFF from the computer link unit.• When a vacant I/O slot's input "x" is turned ON/OFF by the GOT touch-switch
function (bit SET/RST/alternate/momentary).
13. For connection to a Q4ARCPU redundant system(1) For a bus connection with a Q4ARCPU redundant system
Connect the GOT to the redundant system extension base unit (A68RB) at the Q4ARCPU redundant system's last stage. A version "B" or later redundant system extension base unit must be used. The redundant system extension base unit's version is indicated in the "DATE" column at the rated plate.Note Q4ARCPU redundant system configuration precautions
GOT will not operate properly in the following system configurations.• When GOT is bus-connected to the bus switching unit (A6RAF) of the
redundant system main base unit (A32RB/A33RB).• When GOT is bus-connected to a version "A" redundant system extension
base unit (A68RB).
(2) Power ON order for GOT and a Q4ARCPU redundant systemThe power ON order for GOT and a Q4ARCPU redundant system should be as follows.1) GOT power ON.2) After the monitor screen displays at GOT, the Q4ARCPU redundant system power switches
ON. As a "time-out" system alarm then displays, use the system information to reset the alarm.
S p e c i f i c a t i o n
Component Names
GT15
GT11
Handy GOT
RS-232 interface
USB interface
Battery
CF card access LED
Environmentally protective cover
Emergency stop switch
CF card interface
RS-232 interface
USB interface
Power supply terminal
RS-422 interface
POWER LED
POWER LED
Key type selector switch
Operation switches (6 switches)
RS-422/232 interface
Touch panel
Grip switch
CF card access switch
CF card interface
CF card cover
Optional function board interface (shipped with cover)
RESET switch
Touch panel
Hook for wall mounting
Rear face protective cover
Hook for neck strap
Optional function board interfaceBattery
Hand strap
Type
Screen size
Resolution
Display size
Number of display characters
Display color
View angle
Contrast adjustment
Intensity
Life
Life *2
Number of touch keys
Key size
No. of simultaneous touch points
Life
Detection distance
Detection range
Detection delay time
C drive
Life (number of writings)
Backed up data
Life
RS-232
USB
CF card
Optional function board
Multi-color display
Extension unit
Drawing software
Simulator function
TFT color display
(High-brightness, wide viewing angle)
SVGA: 800 x 600 [dot]
For 16-dot standard font
: 50 chars. x 37 lines (two bytes)
For 12-dot standard font
: 66 chars. x 50 lines (two bytes)
256 colors / 65536 colors *1
8-step adjustment
Approx. 50,000 hours
(operating ambient temperature: 25°C)
1900 keys per screen
(38 lines x 50 columns matrix resistive type)
Min. 16 x 16 [dots]
(per key) (16 x 8 at final line only)
9 MB built-in flash memory
(for saving project data, extended function OS/optional function OS)
1ch for multi-color display board installation
256 colors
Approx. 40,000 hours or more
Max. 2 points
2.3 [kg]
(excluding the mounting bracket)
10.4"
211(W) x 158(H) [mm]
Cold cathode fluorescent tube (replaceable) with backlight OFF detection function, and selectable backlight OFF / screen save time
(time for display intensity to become 50% at operating ambient temperature of 25°C)
1,000,000 or more operations (pressing force of 0.98N or less)
100,000 writings
GT15-BAT type lithium battery (optional)
Clock and maintenance schedule notification data
Approx. 5 years (operating ambient temperature: 25°C)
RS-232, 1ch, Transmission speed: 115200, 57600, 38400, 19200, 9600, 4800 bps Connector shape: D-sub 9-pin (male)
Application: Communication with connected devices, connection to personal computer (for project data uploads/downloads, OS installation, FA transparent function)
USB (Full Speed 12Mbps), device, 1ch, Connector shape: Mini-B
Application: Connection to personal computer (for project data uploads/downloads, OS installation, FA transparent function)
Compact Flash slot: 1ch, Connector shape: TYPE I, Application: For data transmission and data saving
1ch for optional function board installation
2ch for communication unit installation
Single tone (tone length is adjustable)
JEM1030 Front face: IP67f *5 Inside panel: IP2X
303(W) x 214(H) x 49(D) [mm]
289(W) x 200(H) [mm]
GT Designer2 Version 2.18U or later
GT Simulator2 Version 2.18U or later
8.4"
171(W) x 128(H) [mm]
241(W) x 190(H) x 52(D) [mm]
227(W) x 176(H) [mm]
1.9 [kg]
(excluding the mounting bracket)
TFT color display (High-
brightness, wide viewing angle)
256 colors / 65536 colors *1
Right/left: 65°, Up: 50°, Down: 60°
380 [cd/m2]
8-step adjustment
9 MB built-in flash memory
(for saving project data,
extended function OS/
optional function OS)
1ch for multi-color display board installation
TFT color display
Right/left: 45°, Up: 30°, Down: 20°
200 [cd/m2]
4-step adjustment
5 MB built-in flash memory
(for saving project data, extended
function OS/optional function OS)
1(m)
Right, left, up, down: 70°
0 to 4 [sec]
Right/left: 50°, Up: 35°, Down: 45°
280 [cd/m2]
2.4 [kg]
(excluding the mounting bracket)
12. 1"
246(W) x 184.5(H)[ mm]
Right/left: 60°, Up: 40°, Down: 50°
350 [cd/m2]
316(W) x 242(H) x 52(D) [mm]
302(W) x 228(H) [mm]
2.8 [kg]
(excluding the mounting bracket)
Right, left, up,down: 85°
380 [cd/m2]
15"
XGA:1024 x 768 [dot]
304.1(W) x 228.1(H) [mm]
For 16-dot standard font
: 64 chars. x 48 lines (two bytes)
For 12-dot standard font
: 85 chars. x 64 lines (two bytes)
Right/left: 75°, Up: 50°, Down: 60°
450 [cd/m2]
Approx. 52,000 hours (operating
ambient temperature: 25°C)
Approx. 50,000 hours or more
3072 keys per screen
(48 lines x 64 columns )
Min. 16 x 16 [dots]
(per key)
Simultaneous touch
prohibited*3 (1 point only)
397(W) x 296(H) x 61(D) [mm]
383.5(W) x 282.5(H) [mm]
4.9 [kg]
(excluding the mounting bracket)
TFT color display
16 colors
Right/left: 45°, Up: 20°, Down: 20°
150 [cd/m2]
4-step adjustment
5 MB built-in flash memory
(for saving project data,
extended function OS/
optional function OS)
VGA:640 x 480 [dot]
For 16-dot standard font: 40 chars. x 30 lines (two bytes)
For 12-dot standard font: 53 chars. x 40 lines (two bytes)
16 colors
Approx. 41,000 hours
(operating ambient temperature: 25°C)
1200 keys per screen
(30 lines x 40 columns matrix resistive type)
Min. 16 x 16 [dots]
(per key)
Item GT1585-STBA
GT1585-STBDGT1595-XTBA
GT1575-STBA
GT1575-STBD
SpecificationGT1575-VTBA
GT1575-VTBD
GT1572-VNBA
GT1572-VNBD
GT1575-VNBA
GT1575-VNBD
GT1565-VTBA
GT1565-VTBD
GT1562-VNBA
GT1562-VNBD
Display
Backlight
Touch panel
Human sensor
Memory*4
Battery
Built-in interface
Buzzer output
Environmentally protective construction
External dimensions (without USB port cover)
Panel cut dimensions
Weight
Supported software package
Performance specifications(GT15)
100 to 240VAC (+10%, -15%)
50/60Hz ±5%
28W or less
20W or less
45A or less (4ms, at max. load)
Within 20ms (100VAC or more)
Noise width 1 µs, and noise frequency 25 to 60 Hz,
by noise simulation with noise voltage 1,500 Vp-p
1500VAC between power supply terminal and ground for 1 minute
31W or less (1290mA/24VDC) 26W or less (1080mA/24VDC)
90VA (at max. load)
24VDC (+25%, -20%)
20W or less (830mA/24VDC)
115A or less (1ms, at max. load)
Within 10ms
Noise width 1 µs, and noise frequency 25 to 60 Hz,
by noise simulation with noise voltage 500 Vp-p
500VAC between power supply terminal and ground for 1 minute
110VA (at max. load)
51W or less
28W or less
50A or less (4ms, at max. load)
26W or less
20W or less
40A or less (4ms, at max. load)
10M½ or higher with an insulation resistance tester (500VDC between power supply terminal and ground)
0.75 to 2 [mm2]
Crimp terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A
0.5 to 0.8 [N·m]
24VDC (+10%, -15%)
4.32W or less (180mA/24VDC)
15A or less (2ms, at max. load)
Within 5ms
Noise width 1 µs, and noise frequency 30 to 100 Hz,
by noise simulation with noise voltage 1,000 Vp-p
500VAC between power supply terminal and ground for 1 minute
10M½ or higher with an insulation resistance tester
(500VDC between power supply terminal and ground)
0.75 to 2 [mm2]*1
Crimp terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A*1
0.5 to 0.8 [N·m]*1
9.36W or less (390mA/24VDC)9.84W or less (410mA/24VDC)
Item GT1585-STBAGT1595-XTBA
GT1575-STBAGT1575-VTBAGT1575-VNBAGT1572-VNBAGT1565-VTBAGT1562-VNBA
Specification
GT1585-STBD
GT1575-STBDGT1575-VTBDGT1575-VNBDGT1572-VNBDGT1565-VTBDGT1562-VNBD
GT1155-QSBDGT1155HS-QSBD
GT1150-QLBDGT1150HS-QLBD
Input power supply voltage
Input frequency
Input maximum voltampere
Power consumption
Rush current
Permissible instantaneous failure time
Noise resistance
Dielectric withstand voltage
Insulation resistance
Applicable wire size
Crimp terminal
Tightening torque (terminal block's terminal screws)
With backlight off
Power supply specifications
Type
Screen size
Resolution
Display size
Number of display characters
Display color
View angle
Contrast adjustment
Contrast adjustment
Intensity
Life
Life *1
Number of touch keys
Key size
No. of simultaneous touch points
Life
C drive
Life (number of writings)
Backed up data
Life
RS-422
RS-422/232
RS-232
USB
CF card
Optional function board
Drawing software
Simulator function
ItemGT1150-QLBDGT1155-QSBD
Specification
GT1155HS-QSBD GT1150HS-QLBD
Display
Backlight
Touch panel
Memory*2
Battery
Built-in
interface
Buzzer output
Environmentally protective construction
External dimensions (without USB port cover)
Panel cut dimensions
Weight
Supported
software package
Performance specifications (GT11)
48 49
Sp
ecificationSTN color display
256 colors
Right/left: 50°,
Up: 50°, Down: 60°
350 [cd/m2]
Approx. 75,000 hours or more
5.7"
QVGA: 320 x 240 [dot]
115(W) x 86(H) [mm]
For 16-dot standard font: 20 chars. x 15 lines (two bytes),For 12-dot standard font: 26 chars. x 20 lines (two bytes)
16-step adjustment
8-step adjustment
Approx. 50,000 hours (operating ambient temperature: 25°C)
Cold cathode fluorescent tube (not replaceable) with backlight OFF detection function, and selectable backlight OFF / screen save time
(time for display intensity to become 50% at operating ambient temperature of 25°C)
300 keys per screen (15 lines x 20 columns matrix resistive type)
Min. 16 x 16 [dots] (per key)
Max. 2 points
1,000,000 or more operations (pressing force of 0.98N or less)
3 MB built-in flash memory (for saving project data)
100,000 writings
GT11-50BAT type lithium battery
Clock, alarm history, recipe data
Approx. 5 years (operating ambient temperature: 25°C)
USB (Full Speed 12Mbps), device, 1ch Connector shape: Mini-B Application: communication with
personal computer (for project data uploads/downloads, OS installation, FA transparent function)
Compact Flash slot: 1ch, Connector shape: TYPE I, Application: For data transmission and data saving
1ch for optional function board installation
Single tone (tone length is adjustable)
GT Designer2 Version 2.18U or later
GT Simulator2 Version 2.18U or late
RS-422, 1ch, Transmission speed: 115200,
57600, 38400, 19200, 9600, 4800 bps
Connector shape: D-sub 9-pin (female)
Application: Communication with connected devices
RS-232, 1ch, Transmission speed: 115200,
57600, 38400, 19200, 9600, 4800 bps
Connector shape: D-sub 9-pin (male)
Application: Communication with connected devices,
connection to personal computer (for project data uploads/
downloads, OS installation, FA transparent function)
JEM1030 Front face: IP67f *3 Inside panel: IP2X
164(W) x 135(H) x 56(D) [mm]
153(W) x 121(H) [mm]
0.7 [kg] (excluding the mounting bracket)
RS-422/232, 2ch (select 1ch when using)
Transmission speed: 115200, 57600, 38400,
19200, 9600, 4800 bps
Connector shape: Round 32-pin (male)
Application: Communication with connected devices
RS-232, 1ch, Transmission speed: 115200,
57600, 38400, 19200, 9600, 4800 bps
Connector shape: Mini-DIN6-pin (female)
Application: Communication with connected devices,
connection to personal computer (for project data uploads/
downloads, OS installation, FA transparent function)
JEM1030 IP65f *4
176(W) x 220(H) x 93(D) [mm]
1.0 [kg] (Main unit only)
STN monochrome (black/white) display
16-tone gray scales
Right/left: 45°,
Up: 20°, Down: 40°
220 [cd/m2]
Approx. 54,000 hours or more
STN monochrome (black/white) display
16-tone gray scales
Right/left: 45°,
Up: 20°, Down: 40°
220 [cd/m2]
Approx. 54,000 hours or more
STN color display
256 colors
Right/left: 50°,
Up: 50°, Down: 60°
350 [cd/m2]
Approx. 75,000 hours or more
*1: 65,536 colors when multi-color display board is installed.*2: Using the GOT screen save / backlight OFF functions prevents screen burn-in and extends the backlight life.*3: Analog resistance film type screen. When 2 points on the screen are touched simultaneously, if a switch is located in
the middle of the 2 points then the switch will be activated. Therefore, avoid touching 2 points on the screen simultaneously.
*4: The internal memory is a ROM that permits new data overwriting without having to delete the existing data.
*5: Conforms to the IP67f (JEM1030) standard when the USB port cover is installed. (The USB interface conforms to IP2X (JEM1030) when a USB cable is connected.) However, this does not guarantee protection in all user environments.
On LCD screens, bright dots (permanently lit) and black dots (not to be lit) generally appear. Because the large number of display elements exist on an LCD screen, it is not possible to reduce appearance of the bright and black dots to zero. Note that the existence of bright and black dots is a standard characteristic of LCD screens, and it does not mean that the products are defective or damaged.
POWER LED
Power supply terminal
Extension unit interface
Optional function board interface
Multi-color display board interface
CF card interface
S.MODE(OS installation switch)(GT1595 only)
CF card access LED
RESET switch
Battery holder
USB interface
CF card access switch
RS-232 interface
Touch panel
Human sensor (GT1595, GT1585 only)
* This illustration shows the GT1595-XTBA.
*1: Using the GOT screen save / backlight OFF functions prevents screen burn-in and extends the backlight life.*2: The internal memory is a ROM that permits new data overwriting without having to delete the existing data.*3: Conforms to the IP67f (JEM1030) standard when the USB port cover is installed. (The USB interface conforms to IP2X
(JEM1030) when a USB cable is connected.) However, this does not guarantee protection in all user environments.*4: Does not apply when IP65f-rated interface covers on top and rear face are removed.
On LCD screens, bright dots (permanently lit) and black dots (not to be lit) generally appear. Because the large number of display elements exist on an LCD screen, it is not possible to reduce appearance of the bright and black dots to zero. Note that the existence of bright and black dots is a standard characteristic of LCD screens, and it does not mean that the products are defective or damaged.
*1: Excluding GT115□HS.
0 to 50°C*6
0 to 55°C*6
-20 to 60°C
10 to 90% RH, no condensing
10 to 90% RH, no condensing
Based on JIS B 3502, IEC 61131-2 (147m/s2, 3 times in X, Y and Z directions)
No corrosive gas
2000m or less
Inside the control panel
II or lower
2 or less
Self cooling
If intermittent vibration occurs
If continuous vibration occurs
Frequency
5 to 9Hz
9 to 150Hz
5 to 9Hz
9 to 150Hz
Acceleration
9.8m/s2
4.9m/s2
Single amplitude
3.5mm
1.75mm
Sweep count
Item SpecificationDisplay
Other than display
Storage ambient temperature
Operating ambient humidity*1
Storage ambient humidity*1
Vibration resistance*2
Impact resistance
Operating atmosphere
Altitude*3
Installation location
Overvoltage category*4
Contamination*5
Cooling method
General specifications*1: Wet bulb temperature for STN display type is 39°C or lower.*2: Refer to the Communication Unit User's Manual for vibration re-
sistance specifications when using a MELSECNET/10 commu-nication unit (GT15-75J71LP23-Z, GT15-75J71BR13-Z) or a CC-Link communication unit (GT15-75J61BT13-Z). Communi-cation units specs. are different from GOT specs.
*3: Do not operate or store the GOT unit in pressurized environ-ments where the pressure exceeds the 0m elevation atmos-pheric pressure, as this could result in abnormal operation.
*4: Assuming that the device is connected at some point between a public power distribution network and local system equip-ment. Category II applies to devices that are supplied with pow-er from fixed equipment. The surge withstand voltage is 2500V for devices with ratings up to 300V.
*5: Index that indicates the level of foreign conductive matter in the operating environment of device. Contamination level 2 de-notes contamination by non-conductive matter only, though momentary conductivity may occur due to occasional conden-sation.
*6: 0 to 40°C for GT115□HS.*7: Excluding GT115□HS.
Operating ambi-ent temperature
Based on
JIS B 3502,
IEC61131-2
10 times in each of X, Y, and Z di-rections
GT1155GT1150
Handy GOT
GT1575
GT1565
GT1585GT1595
Size GOT main unit typeGT1595GT1585GT1575GT1565GT1155GT1150
15" type12.1" type10.4" type
8.4" type5.7" type5.7" type
A
BC,DE
When only GOT or a bus connection unit*1 is installedWhen a bus connection unit*2, or a serial communication unit is connectedWhen an RS-422 converter is installedWhen an Ethernet communication unit, a MELSECNET/10 communication unit (coaxial), or a CC-Link communication unit is installedWhen a MELSECNET/10 communication unit (optical) is installed
51 or more
50 or more (26 or more)
50 or more
50 or more (20 or more)
50 or more (20 or more)50 or more (20 or more)
50 or more (36 or more)50 or more (36 or more)73 or more
50 or more (48 or more)
50 or more (20 or more)
80 or more (20 or more)50 or more (20 or more)
100 or more (20 or more)
50 or more (31 or more)50 or more (31 or more)68 or more
50 or more (43 or more)
Item GT1585GT1595 GT1575 GT1565
A383.5302289227
153
B282.5228200176
121
mExternal dimensions
mPanel cut dimensions
mProduct installation interval
When a GOT is installed, the spaces must be provided between other equipment as shown below.
Bus connection unit
Serial communication unit
RS-422 conversionunit
Bus extension connector boxBus connector conversion boxMELSECNET/10 communication unitCC-Link communication unitEthernet communication unit
A +2 0
B +2 0Panel opening
(Unit: mm)
(Unit: mm)
(Unit: mm)
(Unit: mm)
(Unit: mm)
(Unit: mm)
Product nameQ-BUS (1ch) unit, standard modelQ-BUS (2ch) unit, standard modelA-BUS (1ch) unit, standard modelA-BUS (2ch) unit, standard modelQ-BUS (1ch) unit, slim modelQ-BUS (2ch) unit, slim modelA-BUS (1ch) unit, slim modelA-BUS (2ch) unit, slim modelRS-232 serial communication unit(D-sub 9-pin (male))RS-422/485 serial communication unit (D-sub, 9-pin (female))RS-422/485 serial communication unit (Terminal block)RS-232 → RS-422 conversion unit (9-pin)RS-232 → RS-422 conversion unit (25-pin)
Optical loopCoaxial busIntelligent device station
GT15-QBUSGT15-QBUS2GT15-ABUSGT15-ABUS2GT15-75QBUSLGT15-75QBUS2LGT15-75ABUSLGT15-75ABUS2L
GT15-RS2-9P
GT15-RS4-9S
GT15-RS4-TE
GT15-RS2T4-9P
GT15-RS2T4-25P
A9GT-QCNBA7GT-CNBGT15-75J71LP23-ZGT15-75J71BR13-ZGT15-75J61BT13-ZGT15-J71E71-100
Model nameFig. 17Fig. 18Fig. 17Fig. 18Fig. 19Fig. 20Fig. 19�Fig. 20�
Fig. 21
Fig. 21
Fig. 22
Fig. 23
Fig. 24�
Fig. 25�Fig. 26�Fig. 27�Fig. 28�Fig. 29Fig. 30
Externaldimensions
2.32.54.54.5
A0.53.00.83.0
B12111511
C31.529
29.531
D
33.531
EGT15-QBUSGT15-QBUS2GT15-ABUSGT15-ABUS2
Model name
53 47
120
1010
152
135
164
Other device or control panel
C
A
B
DE
Plate thickness: 2 to 4mm
*1: Only applies to the GT15-75QBUSL, GT15-75QBUS2L, GT15-75ABUSL, and GT15-75ABUS2L.*2: Only applies to the GT15-QBUS, GT15-QBUS2, and GT15-ABUS2.· Dimensions shown in parentheses apply when there are no devices nearby (contactor, etc.) which produce radiated noise or heat. Even with these dimensions, however, the ambient temperature must never exceed 55°C. Depending on the unit and cable being used, a cable length longer than the dimension A shown above may be required.
*1: Same dimensions as the A985GOT (-V).*2: Same dimensions as the A975/970GOT (-B).*3: Same dimensions as the F940GOT.
SizeWithout CF Card
5.7" type 50 or more
With CF Card100 or more 50 or more
C A,D
80 or more
B E
100 or more
* The GOT ambient temperature must always be 55°C or less.
*1
*2
*3
*3
E x t e r n a l d i m e n s i o n s
Fig.17
Fig.20
Fig.21
Fig.22
Fig.23
Fig.24
Fig.25
Fig.26
Fig.27
Fig.29
Fig.30
Fig.28
Fig.18
Fig.19
GOT main unit
Communication unit
301
250
316
263
1010
56 6 52
5
227
242
226
175.5
175.5
241
56
190
175
1010
5265
222
303
252
56 49
56
214
199
1010
288
120
120
56
5
v15" type /12.1" type / 10.4" type / 8.4" type
v5.7" type
2.32.33.93.9
AGT15-75QBUSLGT15-75QBUS2LGT15-75ABUSLGT15-75ABUS2L
Model name *4: Dimension A of each communication unit.
*3: Dimension X when mounting GOT *5: Dimension X when mounting GOT
*1: Connector shapes vary according to the model name.*2: Dimensions A to E of each communication unit.
50 51
Extern
al dim
ensio
ns
397
320
296
320
61 65
382
1028
110
1362
176
1620
4
209
168
3.574
6272
50
7518
GOT main unit63 3 B
798
2.5
30.5
21.5
107
A
X
D
C
GOT main unit
A
X
133
107
30.5
21.5
2.5
98
3 B
D
C
E
*1*2*3
*1*2*3
*1*3
*5
*3
*5
*3*5
*1*4
*1*4
X
798 11
2
2.5
30.5
31.5
21.5
3 GOT main unit630.5
9
X
GOT main unit63 30.5
1298
2.5
30.5
21.5
117
29.5
11.5
Front
Bottom
136.8Side
101.
8A
17.6
Front
Bottom
136.8Side
101.
8A
17.6
20.5
3848
44.5
57
RS-232
RS-422
20.5
3848
44.5
57
RS-232
RS-422
20 89.7
64.2
46.7
48
39.54.25 4.25
20155
8071.5
4.25
4.25
Mounting hole
From base unit
102
34X
150
GT15-75IF900
GT
15-7
5IF
900
GOT main unit
150
102
34
GT15-75IF900
GT
15
-75IF
900
When F type connector is installed
X
150
102
39
GT15-75IF900
GT
15-75IF900
GOT main unit
X
2.5
21
3GOT main unit63
0.5
98 112
0.47
8
30.5
21.5
X
To bus connection unit
Whenthe connector
is installed
Whenthe connectoris installed
GOT main unit
8.4" type10.4" type, 12.1" type, 15" type
8.4" type10.4" type, 12.1" type, 15" type
2321
15.513.5
GT15-QCMBGT15-QCMBSGT15-CMNBGT15-ACMBGT15-A370CMB-S1GT15-A370CMBGT15-A1SCMBGT15-A1SCMNBGT15-CMEXSS-1*1
GT15-EXCNBGT15-CMBSGT15-J2C10B
*1: The GT15-CMEXSS-1 is a set product consisting of the GT15-EXCNB and GT15-CMBS. (See Fig. A)
GT15-EXCNB (Fig. 8) GT15-CMBS (Fig. 9)
(Unit: mm)
(Unit: mm)
Fig. A
PLC side GOT side
~
Cable model name0.6, 1.2, 3, 5, 10 m15, 20, 25, 30, 35 m1.2, 3, 5 m0.6, 1.2, 3, 5 m1.2, 2.5 m1.2, 2.5 m0.7, 1.2, 3, 5 m0.45, 0.7, 3, 5 m10.6, 20.6, 30.6 m0.5 m0.7, 1.2, 3, 5, 10, 20, 30 m1 m
Fig. 1Fig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7
Fig. 8 + Fig. 9Fig. 8Fig. 9
Fig. 10
Cable length (L) External dimensions
GT01-C30R4-25PGT01-CMR4-25PGT01-CMR4-8P
Cable model name3 m10, 20, 30 m1, 3, 10, 20, 30 m
Fig. 11Fig. 12Fig. 13
Cable length (L) External dimensions
GT01-C30R2-6PGT01-C30R2-9SGT01-C30R2-25P
Cable model name3 m3 m3 m
Fig. 14Fig. 15Fig. 16
Cable length External dimensions Fig.13
Fig.12
Fig.11
Fig.5
Fig.4
Fig.3
Fig.2
Fig.1
Fig.10
Fig.9
Fig.8
Fig.7
Fig.6
Bus connection cable
RS-422 cable
RS-232 cable
5016
35
53 16
55
3000
Ø7
16 50 53L
35 55
Ø7
16
Ø15 x 28.5Ø6
50 4016
35
13
13
L16 50 533000
35
16
55
Ø6
16 50 503000
35
16
35
Ø6
10
42
34.2145
L95
Cable approx. Ø10
Ferrite core, approx. Ø35 x 40, red holder tube
Ferrite core, approx. Ø35 x 40, green holder tube
A0J2-PW side
GOT side
Cable approx. Ø8.01000
7033 12.4
49.9
100
12.433
49.9 C
ON
1
1000 FG cable
500Cable approx. Ø9.0PLC side GOT side
CO
N2
GO
T side 60
75 20.5
12.4 33110
L50
60 20
49.9
58
Ferrite core, approx. Ø35 x 40, green holder tube
Motion controller sideA7GT-CNB side
Cable approx. Ø8.0
12.4 33
110
49.9
L
Cable approx. Ø8.0
Ferrite core, approx. Ø35 x 40, green holder tube
50
12.4 33110 Cable approx. Ø8.0
L50
60 20
49.9
Ferrite core, approx. Ø35 x 40, green holder tube
PLC sideA7GT-CNB side
58
20 60 L50
Cable approx. Ø17.070
Ferrite core, approx. Ø32 x 16, green holder tube
58
12.4
49.9
33160
L
Cable approx. Ø8.0 110
Ferrite core, approx. Ø35 x 40, green holder tube
20 60
58
70 Cable approx. Ø8.0
Ferrite core, approx. Ø35 x 40, green holder tube
PLC sideGOT side
5033
12.4
49.9
L
12.4
49.9
33 L
Cable approx. Ø9.0
FG cable
Ferrite core, approx. Ø35 x 40, blue holder tube
110160
CO
N1
CO
N2
GO
T side
16 50 40 13
13
3000
35
Ø7Ø20 x 28
Fig.16
Fig.15
Fig.14
Model
Function Description Page
GT11GT15
GT1585-STBM
GT1575-STBM
GT1575-VTBM
GT1565-VTBM
GT1155-QSBD
GT1150HS-QLBD
Bus connection
CPU direct connection
Computer link connection
MELSECNET/10 connection
CC-Link connection (ID/via G4)
Ethernet connection
Connection to
other brand PLCs
Microcomputer connection
Temperature controller connection
Inverter connection
Servo amplifier connection
CNC connection
Standard memory capacity
Total memory capacity when
using option (standard + option)
65536 colors
256 colors
16 colors
16 gray scales
1024 x 768 dot
800 x 600 dot
640 x 480 dot
320 x 240 dot
Number of touch keys
(line x row)
RS-232 interface
RS-422 interface
RS-422/232 interface
USB (USB (Full Speed 12Mbps
device 1ch (Mini-B))
CF card interface (Compact
Flash slot 1ch (TYPE 1))
Optional function
board interface (1ch)
Extension unit interface (2ch)
Vertical display
Clock function
Buzzer output
Human sensor
Backlight OFF
detection function
Environmentally protective construction
Boot OS installation
OS installation*4
Project data downloads
/uploads *5
Resource data uploads *6
FA transparent function
Multi-channel function
Gateway function
Base screen
Superimposed window display
Overlap window display
Supported image data
format
Standard font
High-quality font
TrueType font
Windows ® font
Simplified Chinese [GB]
/ Mincho (GB2312)
Traditional Chinese [Big5]
/ Gothic font
Part (object + figure) Layer function
For connectable PLCs, refer to
the "Connectable model list" on page 30
Communication protocol (15 type) compatible
CPU direct connection
MELSECNET/10 connection
CC-Link (ID) connection
Ethernet connection
Optional expansion memory function board.
Requires (GT15-QFNBMM) + CF card.
Multi-color display board is required.
For PC communication (project data downloads/
uploads, OS installation, FA transparent function)
For data transmission and data saving
For optional function board installation
(only for GT15 with expansion memory)
For communication unit installation
GT15 requires a battery (GT15-BAT)
to save clock data.
Monotone (tone length is adjustable)
GT15 backlight is replaceable.
GT1155-QSBD features a long-life backlight.
Via USB or RS-232, using CF card
Via Ethernet (GT15 only)*7,
Via USB or RS-232, using CF card
Via USB or RS-232
Basic GOT display screen
Composite display windows on the base screen
Pop-up window
BMP image data
JPEG image data
DXF data
Re-quired
Required
Required
Re-quired
Re-quired
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
9MB
Max.
57MB
v
v
v
3072
(48 x 60)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
9MB
Max.
57MB
v
v
v
1200
(30 x 40)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
5MB
Max.
53MB
v
v
1200
(30 x 40)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Via G4 only
v
v
v
v
v
v
3MB
v
v
300
(15 x 20)
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Via G4 only
v
v
v
v
v
v
3MB
v
v
300
(15 x 20)
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Via G4 only
v
v
v
v
v
v
3MB
v
v
300
(15 x 20)
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Via G4 only
v
v
v
v
v
v
3MB
v
v
300
(15 x 20)
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
9MB
Max.
57MB
v
v
v
1900
(38 x 50)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
9MB
Max.
57MB
v
v
v
1900
(38 x 50)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
9MB
Max.
57MB
v
v
v
1200
(30 x 40)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
5MB
Max.
53MB
v
v
1200
(30 x 40)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
5MB
Max.
53MB
v
v
1200
(30 x 40)
v
*3
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Required
Re-quired
Re-quired
P.28
P.8, 28
P.28
P.11,48
P.19,48
P.48
P.21,48
P.48
P.48
P.20
P.20
P.9,55
P.10
P.11
P.19
P.11
P.12
P.12
P.13
P.22
P.15
P.14
P.15
P.13
P.24
P.25
P.24
P.16
P.18
12.1" 10.4" 10.4" 8.4" 5.7"5.7"SVGASVGA
GT1595-XTBA
15"XGA VGA
GT1575-VNBM
10.4"VGA
GT1572-VNBM
10.4"VGA VGA
GT1562-VNBM
8.4"VGA QVGA QVGA
GT1150-QLBD
5.7"QVGA
GT1155HS-QSBD
5.7"QVGA
*1: Function contents, such as the number of points to set and the destination to save files, vary according to the model.*2: For details, see the "Notes for use" section on page 54.*3: The RS-232 interface is used as an RS-422 interface by installing an RS-422 converter. *4: "OS" refers to the basic functions, communication drivers, extended functions, and optional functions.*5: "Project data" refers to user screen data (base screen, window screen), components, advanced recipes, comments, common settings, high-quality font, and the boot logo.*6: "Resource data" refers to the alarm log files (advanced alarms, alarm history), recipe files, advanced recipe files, data log files, screen transition information files, and hard copy files. The GT11 supports only the alarm log file (alarm history).*7: The GOT with basic functions installed must be equipped with an Ethernet communication unit.*8: Only 16-dot fonts (standard / high-quality Mincho font) are available.*9: Settings of the logging function are required in order to use historical trend graph function. In addition, the optional function board and optional function OS (Logging) must be installed.*10: Structural restrictions apply.
*1
F u n c t i o n l i s t f o r e a c h m o d e l
53
List o
f pro
du
cts
Con
nect
ion
conf
igur
atio
nU
ser
me
mo
ry
cap
aci
tyD
ispl
ay
colo
rsR
esol
utio
nT
ouch
keys
Inte
rnal
inte
rfac
eO
ther
Spe
cific
atio
nsM
ain
unit
func
tions
Har
dwar
e sp
ecifi
catio
nsS
cree
n de
sign
Cat
egor
y
Model
Function Description GT1585-STBM
GT1575-STBM
GT1575-VTBM
GT1565-VTBM
GT1155-QSBD
GT1150HS-QLBD
Screen switching
Station No. switching
Multilingual support function
Password
System information
Connected device setting
Boot logo
Comment registration
Parts registration
Data operation function
Offset function
Security function
Lamp display
Touch switch
Numerical display/input
Data list display
ASCII display/input
Kana-kanji conversion function
Clock display
Comment display
Advanced alarm
observation/display
Alarm list display
Alarm history display
Parts display
Parts movement
Panel meter display
Level display
Trend graph
Historical trend graph*9
Line graph
Bar graph
Statistical graph
Scatter graph
Status observation function
Advanced recipe
Recipe function
Time action function
Hard copy function
(File saved in CF card)
Bar-code function
Screen call function
Logging function
Script function
System monitor function
List editor for A
List editor for FX
Ladder monitor function
Intelligent unit monitor function
Q motion monitor function
Servo amplifier monitor function
Network monitor function
CNC monitor function
Maintenance notification function
GT Works2 Version2
GT Designer2 Version2
GT Simulator2 Version2
GT Converter2 Version2
Multilingual support device switches
the language of objects with comment groups.
Channel No. driver setting is required
Displays the desired image (BMP) at GOT startup.
1 basic comment per project*8
255 comment groups per project
ASCII inputs limited to 16 chars.
Lower/higher bit display order is selectable.
Advanced user alarm / advanced system
alarm / advanced alarm popup window
User alarm display / system alarm display
File saved in CF card (BMP, JPEG)
CF card is required
Project script
Screen script
Object script
Use the GT15-QFNB (MM) for
the Q/QnA ladder monitor function.
Battery (GT15-BAT) is required
For items shipped with the unit,
see the "Device List" (page 56).
GOT1000 compatible drawing software
GOT1000 compatible simulation software
Easy data convert function
Converts GOT800 series, GP-PRO/
PBIIIC-Package03 to GT15, A900 data
Required
*9
Required
Required
Required
Required
Required
Required
Re-quired
Required
Required
Required
Required
Required
Required
Required
*9
Required
Required
Required
Required
Required
Required
Required
Required
Re-quired
Required
Required
Required
Required
Required
12.1" 10.4" 10.4" 8.4" 5.7"5.7"SVGASVGA
GT1595-XTBA
15"XGA VGA
GT1575-VNBM
10.4"VGA
GT1572-VNBM
10.4"VGA VGA
GT1562-VNBM
8.4"VGA QVGA QVGA
GT1150-QLBD
5.7"QVGA
GT1155HS-QSBD
5.7"QVGA
*1
Com
mon
set
tings
Obj
ect s
ettin
gO
ther
Mai
nten
ance
func
tions
Sof
twar
eS
cree
n de
sign
Cat
egor
y
52
*6 *6 *6 *6
*10 *10
GT11GT15
Opt
iona
l Fu
nctio
n B
oard
Exte
nded
/Opt
ional
Func
tion
OS In
stalla
tion
*2*2
Page
Opt
iona
l Fu
nctio
n B
oard
Exte
nded
/Opt
ional
Func
tion
OS In
stalla
tion
*2*2
Re-quired
Re-quired
Total: Up to 4ch
Total: Up to 4ch
Total: Up to 2ch
Total: Up to 2ch
Total: Up to 2ch
Multi-channel*2
Maintenance notification function
Simplified Chinese [GB] Mincho font
Traditional Chinese [Big5] Gothic font
Recipe
Advanced recipe
Logging
Kana-Kanji conversion function
Object script
Gateway (server, client)
Gateway (mail)
Gateway (FTP)
List editor for MELSEC-A
List editor for MELSEC-FX
Ladder monitor for MELSEC-Q/QnA*2
Ladder monitor for MELSEC-A
Ladder monitor for MELSEC-FX
Intelligent unit monitor
Q motion monitor
Servo amplifier monitor
Network monitor function
CNC monitor function
System monitor
Bar-code
Optional functions*1
Extended functions
*3
*3
1280
1920
100
1241
740
1223
360
100
100
64
1058
1058
1082
523
592
384
607
524
324
588
746
84
None
None
None
None
*4
None
None
None
None
None
None
None
*4
*4
None
None
None
None
None
None
None
None
*4
*4
FunctionsGT15 GT11
Available user data space (KB)
When using multi-channel function
[Table A]When using the GT15
When using the GT11
For project datamGT Designer È GT Designer2 compatibility*
Project data created in GT Designer can be used in GT
Designer2.
mGOT900 series È GOT1000 series compatibility*• Using data from the GOT-A900 series
GOT900 series project data can be used at the GOT1000 series.
• Using data from the GOT-F900 seriesData created in GT Designer and GT Designer2 can be used.
Data must first be converted to GOT-A900 series data, and then
to GOT1000 series data.*: Some data and function items cannot be used (not compatible).
mBus connection cables• The GOT900 series bus connection cable cannot be used by
the GOT1000 series.
• The GOT1000 series bus connection cable cannot be used by
the GOT900 series.
mRS-422 and RS-232 cables• The GOT900 series RS-422 and RS-232 cables cannot be
used by the GOT1000 series.
• The GOT1000 series RS-422 and RS-232 cables cannot be
used by the GOT900 series.
mGOT900 series È GOT1000 series compatibility• The A985GOT(-V) and the GT1585, the A975/970GOT(-B) and
the GT1575, the F940GOT and the GT1155/1150, have the
same panel cut dimensions. Therefore, it is not necessary to
change the mounting holes when replacing an A985GOT(-V),
A975/970GOT(-B), or F940GOT with a GOT1000 series unit.
Panel cut dimensions
N o t e s f o r u s e
mWhen using optional functions & extended functionsIn order to use the optional functions shown in "Table A", an optional function board or an optional expansion memory function board must be installed, regardless of the project data capacity and the available user data space.Depending on the functions used, the OS installation may reduce the available user data space.Refer to "Table A" for the amount of user data space corresponding to the optional function OS and the extended function OS.If there is insufficient user space available, an optional expansion memory function board should be selected.
mSelect according to project data capacityA CF card and an optional function board with expansion memory are required if the project data size exceeds the standard memory capacity*1.Project data should be downloaded to Drive "A" (CF card).• Selecting a CF cardSelect a CF card that exceeds the project data capacity*2.
• Selecting an optional expansion memory function boardSelect an optional function board with expansion memory that has the larger capacity than it is indicated as follows*2: [project data size] - [standard memory capacity*1].
*1:Standard memory capacity vary according to the the model. For details refer to the specification on page 48.*2: This is a general guideline.
mWhen using optional functions & extended functions
Install an optional function board in order to use the "Table A" optional functions.
mAcceptable combinations The following connection combinations are compatible with the multi-channel function.
mCommunication driver A communication driver must be installed for each of the connection configurations. Communication drivers for the 2nd and subsequent channels will be installed in the user area.
*1: The serial connection includes the following connection configurations:· CPU direct connection· CC-Link connection (via G4)· Other brand PLC connection· Inverter connection· CNC connection (CPU direct connection)· Computer link connection· Microcomputer connection· Temperature controller connection· Servo amplifier connection
*2: Because the following communication units cannot be connected together with other communication units (serial communication units, Ethernet communication units, etc.), GOT's built-in RS-232 interface must be used for serial connections. Therefore, the barcode function, the FA transparent function (via RS-232), the Ethernet download function, and the gateway function cannot be used. · Bus connection unit (slim type): GT15-75QBUS(2)L, GT15-75ABUS(2)L· MELSECNET/10 communication unit: GT-15-75J71LP23, GT-15-75J71BR13-Z· CC-Link communication unit: GT15-75J61BT13-Z
mOptional function board Use of the GT15-QFNB (MM) optional function board is required.The GT15-FNB cannot be used.
*1: GT15···Use the optional function board (GT15-QFNB/GT15-FNB) or the optional expansion memory function board (GT15-QFNBMM).GT11···Use the optional function board (GT11-50FNB).
*2: The GT15-FNB does not support the multi-channel function and the MELSEC-Q/QnA ladder monitor function. These functions require the GT15-QFNB (MM).
*3: Installation of the optional function OS is not required.*4: Requires installation of the optional function OS and extended function OS, but the user data area cannot be used.
54 55
No
tes for u
se
For cable
CF card & optional function board selection
Forward compatibility
· Data transmission (also possible at GT11)
· Advanced alarm
· Alarm history (also possible at GT11)
· Advanced recipe
· Recipe
· Logging
· Historical trend graph
· Parts display
· Parts movement
· Hardcopy
The CF card can be used for the following GT15 functions:
Bus connection: 1ch(When using GT15-QBUS (2) or GT15-ABUS (2))Serial connection*1: 1 to 3ch
Bus connection: 1ch(When using GT15-75QBUS (2) or GT15-75ABUS (2) L)Serial connection*1: 1ch
MELSECNET/10 connection (PC-to-PC Network): 1chSerial connection*1: 1ch
CC-Link (ID) connection: 1chSerial connection*1: 1ch
Ethernet connection: 1chSerial connection*1: 1 to 3ch
Serial connection only*1: 1 to 4ch
*2
*2
*2
Total: Up to 4ch
Personal computer
OS
CPU Required memoryFree hard disk spaceDisk driveDisplay colorsDisplay
Others
For installationFor operation
PC/AT compatible machine running Windows®Microsoft® Windows® 98 Operating System (English, Chinese, Korean, German Versions)Microsoft® Windows® Millennium Edition Operating System (English, Chinese, Korean, German Versions)Microsoft® WindowsNT® Workstation 4.0 Operating System (English, Chinese, Korean, German Versions)*2Microsoft® Windows® 2000 Professional Operating System (English, Chinese, Korean, German Versions)*2Pentium 200MHz or higher64MB or more300MB or more100MB or moreCD-ROM disk driveHigh color (16 bit) or moreResolution 800 x 600 dot or more• Internet Explorer Ver. 5.0 or later must be installed.• Mouse, keyboard, printer, CD-ROM drive which are compatible with the above OS.
Microsoft® Windows® XP Professional Operating System (English, Chinese, Korean, German Versions)*1*2
Microsoft® Windows® XP Home Edition Operating System (English, Chinese, Korean, German Versions)*1*2
Pentium II 300MHz or higher128MB or more
Item Description
GT Designer2 (English version) operating environment
GT Simulator2 (English version) operating environment
*1: The following functions are not supported: Compatible Mode, Fast User Switching, Desktop Theme (Font) Change, Remote Desktop.*2: Administrator authority is required to install GT Designer2 on the following systems: Windows NT® Workstation 4.0, Windows® 2000 Professional, Windows® XP Professional, Windows® XP Home Edition; Administrator authority is required to operate GT Designer2 on Windows® XP Professional and Windows® XP Home Edition.
QCPU (A mode), ACPU or motion controller CPU (A series)QCPU (Q mode) (except Q00J/Q00/Q01CPU), QnACPU, FXCPUQ00J/Q00/Q01CPUQ12PHCPU, Q25PHCPUQ12PRHCPU, Q25PRHCPU
PLC CPUs to be simulated Software versionVersion5 "A" Edition or laterVersion5 "E" Edition or laterVersion6.00A or laterVersion6.10L or laterVersion6.20W or later
DescriptionItemPersonal computer
OS
CPURequired memoryFree hard disk space*1
Disk drive
Display colors
Display
Software
For installation (product only) For operation
For project data creation/editing
When GX Simulator is used
PC/AT compatible machine running Windows®Microsoft® Windows® 98 Operating System (English, Chinese, Korean, German Versions)Microsoft® Windows® Millennium Edition Operating System (English, Chinese, Korean, German Versions)Microsoft® WindowsNT® Workstation 4.0 Operating System (English, Chinese, Korean, German Versions)*2*3
Microsoft® Windows® 2000 Professional Operating System (English, Chinese, Korean, German Versions)*3Pentium 200MHz or higher64MB or more250MB or more (For product operation and manual reference: 400MB or more)200MB or moreCD-ROM disk driveGT15 simulator: High Color (16-bit) or moreGT11 simulator: 256 colorsResolution 800 x 600 dot or moreGT Designer2*5
• GX Simulator of the following version is required depending on CPU.*6
Microsoft® Windows® XP Professional Operating System (English, Chinese, Korean, German Versions)*3*4
Microsoft® Windows® XP Home Edition Operating System (English, Chinese, Korean, German Versions)*3*4
Pentium II 300MHz or higher128MB or more
*1: A separate available space is required when using GT Designer2, GX Developer, and GX Simulator.*2: Use WindowsNT® Workstation 4.0 with Service Pack3 or later installed. *3: Administrator authority is required to install GT Simulator2 in the following operating systems.
• WindowsNT® Workstation 4.0• Windows® 2000 Professional• Windows® XP Professional• Windows® XP Home Edition
Moreover, administrator authority is required to use GT Simulator2 in the following operating systems.• Windows® XP Professional• Windows® XP Home Edition
*4: The following functions are not supported.• "Compatibility mode", "user account", "desktop appearance", and "remote desktop"
*5: Use a GT Designer2 that is included in the same GT Works as GT Simulator2.*6: Use only same-language GT Simulator2, GX Developer, and GX Simulator versions.
Model name Specification Applicable modelGT15 GT11
GT15 GT11
Backlight
Optional function board
Multi-color display board
Protection sheet
USB IP67f rated port cover
Emergency stop switch guard
Stand
CF card
Memory card adaptor
Attachment
Battery
GT15-90XLTTGT15-80SLTTGT15-70SLTTGT15-70VLTTGT15-70VLTNGT15-60VLTTGT15-60VLTNGT15-FNBGT15-QFNBGT15-QFNB16MGT15-QFNB32MGT15-QFNB48MGT11-50FNBGT15-XHNBGT15-90PSCBGT15-90PSGBGT15-90PSCWGT15-90PSGWGT15-80PSCBGT15-80PSGBGT15-80PSCWGT15-80PSGWGT15-70PSCBGT15-70PSGBGT15-70PSCWGT15-70PSGWGT15-60PSCBGT15-60PSGBGT15-60PSCWGT15-60PSGWGT11-50PSCBGT11-50PSGBGT11-50PSCWGT11-50PSGWGT11H-50PSCGT15-UCOVGT11-50UCOVGT11H-50ESCOVGT15-90STANDGT15-80STANDGT15-70STANDA9GT-50STANDGT05-MEM-32MCGT05-MEM-64MCGT05-MEM-128MCGT05-MEM-256MCGT05-MEM-ADPCGT15-60ATT-96GT15-60ATT-97GT15-BATGT11-50BAT
Backlight
Optional function board (A/FX ladder monitor)
Optional function board (Q/QnA/A/FX ladder monitor)
Optional function boardMulti-color display board for 65536 color display
Protection sheet for 15" type
Protection sheet for 12.1" type
Protection sheet for 10.4" type
Protection sheet for 8.4" type
Protection sheet for 5.7" type
Protection sheet for 5.7" type (For Handy GOT)
IP67f rated port cover (for replacement) for unit front USB interface
To prevent operational errorDebugging stand for 15" typeDebugging stand for 12.1" typeDebugging stand for 8.4"/10.4" typeDebugging stand for 5.7" type32MB Flash ROM64MB Flash ROM128MB Flash ROM256MB Flash ROMCF card → memory card (TYPE II) conversion adaptor
Attachment for 8.4" type
Data backup battery for clock and maintenance notificationData backup battery for clock, alarm history, and recipes
For 15" type High-brightness, wide viewing angle TFT (XGA)For 12.1" type High-brightness, wide viewing angle TFT (SVGA) For 10.4" type High-brightness, wide viewing angle TFT (SVGA)For 10.4" type High-brightness, wide viewing angle TFT (VGA)For 10.4" type TFT (VGA)For 8.4" type High-brightness, wide viewing angle TFT (VGA)For 8.4" type TFT (VGA)(Without expansion memory)(Without expansion memory)16MB expansion memory32MB expansion memory48MB expansion memory
Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)Anti-glare (Set of 5)Clear with white frame (Set of 5)Anti-glare with white frame (Set of 5)Clear (Set of 5)
A960GOT→ GT1565/GT1562A97 GOT→ GT1565/GT1562
Product name
Options
L i s t o f p r o d u c t s
Product name Model name Specification Applicable model
Bus connection unit
Serial communication unit
RS-422 conversion unit
Ethernet communication unitMELSECNET/10 communication unitCC-Link communication unit
GT15-75QBUSLGT15-75QBUS2LGT15-QBUSGT15-QBUS2GT15-75ABUSLGT15-75ABUS2LGT15-ABUSGT15-ABUS2GT15-RS2-9PGT15-RS4-9SGT15-RS4-TEGT15-RS2T4-9PGT15-RS2T4-25PGT15-J71E71-100GT15-75J71LP23-Z *2
GT15-75J71BR13-Z *2
GT15-75J61BT13-Z *2
Q-BUS (1ch) unit slim model for QCPU (Q-mode) Q-BUS (2ch) unit slim model for QCPU (Q-mode)Q-BUS (1ch) unit standard model for QCPU (Q-mode)Q-BUS (2ch) unit standard model for QCPU (Q-mode)A-BUS (1ch) unit slim model for QnA/ACPUA-BUS (2ch) unit slim model for QnA/ACPUA-BUS (1ch) unit standard model for QnA/ACPUA-BUS (2ch) unit standard model for QnA/ACPURS-232 serial communication unit (D-sub 9-pin (male))RS-422 / 485 serial communication unit (D-sub, 9-pin (female))*1
RS-422 / 485 serial communication unit (Terminal block)*1
RS-232 → RS-422 conversion unit
Ethernet (100Base-TX/10Base-T) unitOptical loop unitCoaxial bus unitIntelligent device station unit
1 connector2 connectors1 connector2 connectors1 connector2 connectors1 connector2 connectors
RS-422 connector 9-pinRS-422 connector 25-pin
Handy GOT
Handy GOT
Communication interface
56 57
List o
f pro
du
cts
Model name Screen size [resolution] Display device Display color Power source Memory size
GT1595
GT1585
GT1575
GT1565
GT1155
GT1150
Handy GOT
GT15
GT11
GT1595-XTBA
GT1585-STBA
GT1585-STBD
GT1575-STBA
GT1575-STBD
GT1575-VTBA
GT1575-VTBD
GT1575-VNBA
GT1575-VNBD
GT1572-VNBA
GT1572-VNBD
GT1565-VTBA
GT1565-VTBD
GT1562-VNBA
GT1562-VNBD
GT1155-QSBD
GT1150-QLBD
GT1155HS-QSBD
GT1150HS-QLBD
15" XGA [1024 x 768 dots]
12.1" SVGA [800 x 600 dots]
10.4" SVGA [800 x 600 dots]
10.4" VGA [640 x 480 dots]
8.4" VGA [640 x 480 dots]
5.7" QVGA [320 x 240 dots]
TFT color display(High-brightness, wide viewing angle)
TFT color display(High-brightness, wide viewing angle)
TFT color display(High-brightness, wide viewing angle)
TFT color display(High-brightness, wide viewing angle)
TFT color display
TFT color display(High-brightness, wide viewing angle)
TFT color display
STN color display
STN monochrome display
STN color display
STN monochrome display
256 colors /
65,536 colors (optional)
256 colors /
65,536 colors (optional)
256 colors /
65,536 colors (optional)
256 colors /
65,536 colors (optional)
256 colors
16 colors
256 colors /
65,536 colors (optional)
16 colors
256 colors
16-tone black/white adjustment
256 colors
16-tone black/white adjustment
100-240VAC
100-240VAC
24VDC
100-240VAC
24VDC
100-240VAC
24VDC
100-240VAC
24VDC
100-240VAC
24VDC
100-240VAC
24VDC
100-240VAC
24VDC
24VDC
9MB
5MB
5MB
9MB
5MB
3MB
GOT main units
Manual Name Content Catalog No.GT Designer2 Version2 Basic Operation/
Data Transfer Manual <For GOT1000 Series>
GT Designer2 Version2 Screen Design Manual
<For GOT1000 Series>
GOT1000 Series Connection Manual
GOT1000 Series Extended/Option Functions Manual
GOT1000 Series Gateway Function Manual
GT15 User's Manual
GT11 User's Manual
GOT1000 Handy GOT User's Manual
GT Simulator2 Version2 Operation Manual
GT Converter2 Version2 Operation Manual
Basic software installation information, basic design techniques, and data transfer to a terminal
Programming manual, including instruction for objects, specifications
System configurations and procedure to create customized cables
Detailed Extended Functions information
Detailed Gateway Information, including specifications, setting, and configurations
General specification overview, parts and settings, external dimensions, mounting, wiring,
optional interfaces
General specification overview, parts and settings, external dimensions, mounting, wiring,
optional interfaces
General specification overview, parts and settings, external dimensions, wiring, optional interfaces,
in addition to explanations of utility, system configurations, and cable fabrication
GT Simulator2 specifications and operating instructions
GT Converter2 operating instructions
SH-080529ENG
SH-080530ENG
SH-080531ENG
SH-080532ENG
SH-080544ENG
SH-080545ENG
SH-080528ENG
JY997D17501A
JY997D20101A
SH-080546ENG
SH-080533ENG
Manuals
Software Software Version RemarksIncluded product
Drawing SoftwareGT Designer2 Ver. 2
Simulation GT Simulator2 Ver. 2
Easy data conversion GT Converter2 Ver. 2
SoftGOTGT SoftGOT2
GT Designer2
Version2
GT Works2
Version2
License key forGT SoftGOT2 *1*2
License key FD forGT SoftGOT2 *1*2
SW2D5C-GTD2-E
SW2D5C-GTD2-EV
SW2D5C-GTWK2-E
SW2D5C-GTWK2-EV
A9GTSOFT-LKEY-P
SW5D5F-SGLKEY-E
English version
English version
English version
Version upgrade software (upgrade GT Designer2 to the latest version)
Version upgrade software (upgrade GT Works2 to the latest version)
DOS/V License key (for D-sub 25-pin and parallel port)
License registration package for personal computer CPU unit
Software
*1: Soon to be supported by the GOT1000 Series.
*2: GT SoftGOT2 License key is required for every DOS/V computer, and GT SoftGOT2 license key FD is required for every personal computer CPU unit.
*1
*1
NEWNEWNEW
NEWNEW
NEWNEW
NEW
NEW
NEW
NEW
NEWNEWNEWNEW
NEW
NEWNEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
coming soon
coming soon
coming soon
GT15 9 5 - X T B AModel name explanation Model name explanation (Options)
GT 15 - 90 XLTT
Full-specification model covering a broad range of applications to be used as stand-alone and network access control.Stand-alone model with full of basic functions.
GT15GT11
Screen sizeCode98765
15"12.1"10.4"
8.4"5.7"
Display colorCode520
256 colors or more16 colors
16-tone gray scales
Mounting typeCodeNoneHS
Panel mounted typeHandy type
ResolutionCodeXSVQ
XGA (1024 x 768 dot)SVGA (800 x 600 dot)VGA (640 x 480 dot)QVGA (320 x 240 dot)
Display deviceCode
T
NSL
TFT color (High-brightness, wide viewing angle)TFT colorSTN colorSTN monochrome
Power supply specsCodeAD
100 to 240VAC24VDC
Model nameCode1511
11H090501
SpecificationCode908075706050
* For inquiries relating to products which conform to UL, cUL, and CE directives, please contact your local sales office.
GT15GT11Handy GOT
Common to both GT15 and GT11
15"12.1"Common to 15", 12.1", 10.4", and 8.4".10.4"8.4"5.7"
Version upgrade
Version upgrade
Version upgrade Version upgrade
Version upgrade
Version upgrade
*1: The unit maybe unusable depending on the connection destination. For details, see the "Connection configuration" section from page 32 and relevant manuals.
*2: All units other than MELSECNET/10 and CC-Link communication units conform to CE / UL/ cUL.
Q bus connection
cable
(For QCPU (Q mode))
Bus extension connector box
A bus connection
cable
(For QnA/ACPU/
motion controller
(A series))
Bus connector conversion box
Buffer circuit cable
RS-422 cable
RS-232 cable
External
connection cable
FA device
connection
relay cable
USB cable
QCPU extension cable
Inter-GOT connection cable
QCPU long-distance
connection cable
Inter-GOT long-distance
connection cable
Large CPU extension cable
Small CPU extension cable
Small CPU extension cable
Small CPU long-distance
connection cable
Inter-GOT connection cable
Inter-GOT long-distance
connection cable
A0J2HCPU connection cable
QnA/A/FXCPU direct
connection cable
Computer link connection cable
FXCPU direct connection cable
FX communication function
extension board connection
cable
QCPU direct connection cable
Data transmission cable
FX communication function
extension board connection
cable
FX communication function
adaptor connection cable
Data transmission cable
FX communication function
adaptor connection cable
Data transmission cable
FA device, power supply,
operation switch
connection cable
RS-422, power supply,
operation switch
connection cable
RS-232, power supply,
operation switch connection cable
Data transmission cable
0.6m
1.2m
3m
5m
10m
15m
20m
25m
30m
35m
1.2m
3m
5m
0.6m
1.2m
3m
5m
1.2m
2.5m
1.2m
2.5m
0.7m
1.2m
3m
5m
0.45m
0.7m
3m
5m
10.6m
20.6m
30.6m
0.7m
1.2m
3m
5m
10m
20m
30m
1m
0.5m
3m
10m
20m
30m
1m
3m
10m
20m
30m
3m
3m
3m
3m
6m
10m
3m
6m
10m
1.5m
1.5m
1.5m
2m
For connection between QCPU and GOT
For connection between GOT and GOT
For long-distance (13.2m or more) connection
between QCPU and GOT (A9GT-QCNB required)
For connection between GOT and GOT
Used for QCPU long-distance (13.2m or more) bus connection
For connection between QnA/ACPU/motion controller CPU
(A series/extension base) and GOT
For connection between QnA/ACPU/motion controller CPU
(A series/extension base) and A7GT-CNB
For connection between motion controller CPU
(A series/main base) and GOT
For connection between motion controller CPU
(A series/main base) and A7GT-CNB
For connection between QnAS/AnSCPU/motion controller CPU
(A series) and GOT
For connection between QnAS/AnSCPU and GOT
For connection between QnAS/AnSCPU/motion controller CPU
(A series) and A7GT-CNB
For connection between QnAS/AnSCPU and A7GT-CNB
For connection between QnAS/AnSCPU/motion controller CPU (A series)
and GOT (Long distance)
For connection between A7GT-CNB and GOT (Long distance)
*Combination of GT15-EXCNB and GT15-C BS
For connection between GOT and GOT
For connection between GOT and GOT
For connection between A0J2HCPU power supply unit (A0J2-PW) and GOT
Used for QnA/ACPU long-distance bus connection
Can be used with GT15-C BS as GT15-C EXSS-1
For connection between QnA/ACPU/motion controller CPU
(A series)/FXCPU (D-sub 9-pin connector) and GOT.
For connection between FA-CNV CBL and GOT.
For connection between serial communication unit and GOT
For connection between FXCPU (MINI-DIN 8-pin connector)
and GOT.
For connection between FXCPU communication function extension
board and GOT.
For connection between QCPU and GOT *Excluding Handy GOT
For connection between personal computer (drawing software)
(D-sub 9-pin: female) and GOT (MINI-DIN 6-pin: female) *Handy GOT only
For connection between FXCPU communication function extension board (D-sub 9-pin
connector) and GOT.
For connection between FXCPU communication function adaptor
(D-sub 9-pin connector) and GOT.
For connection between personal computer (drawing software) (D-sub 9-pin: female) and
GOT (D-sub 9-pin: female)
For connection between FXCPU communication function adaptor (D-sub
25-pin connector) and GOT.
For connection between personal computer (drawing software)
(D-sub 25-pin: male) and GOT (D-sub 9-pin: female)
For connection between FA device connection relay cable and GOT
For connection between FA device, power supply, operation switch and GOT
For connection between FXCPU and GOT
For connection between power supply, operation switch and GOT
For connection between A/QnACPU and GOT
For connection between power supply, operation switch and GOT
For connection between QCPU and GOT
For connection between power supply, operation switch and GOT
For connection between personal computer (drawing software) (USB) and GOT (USB Mini-B)
Product name Model name Cable length
Cable length
3rd partyproducts*1
3rd partyproducts*1Specification
*1: Items listed above are developed by Mitsubishi Electric System & Service Co., LTD., and sold through your local sales office.
*1: Items listed above are developed by Mitsubishi Electric System & Service Co., LTD., and sold through your local sales office.
*2: RS-422 conversion unit (GT15-RS2T4-9P) is required.
CablesApplicable model
RS-232 cable
RS-422 cable
Cable for OMRON PLC
Cable for KEYENCE PLC
Cable for SHARP PLCCable for TOSHIBA PLCCable for Hitachi Industrial Equipment Systems PLC
Cable for Matsushita Electric Works PLC
Cable for Yaskawa Electric PLC
Cable for Yokogawa Electric PLCCable for Allen-Bradley PLC
SIEMENS PLC
Cable for OMRON PLC
Cable for KEYENCE PLC
Cable for SHARP PLC
Cable for TOSHIBA PLC
Cable for Hitachi Industrial Equipment Systems PLC
Cable for Yaskawa Electric PLC
Cable for Yokogawa Electric PLC
GT09-C30R20101-9P
GT09-C30R20102-25SGT09-C30R20103-25PGT09-C30R21101-6PGT09-C30R21102-9SGT09-C30R21103-3TGT09-C30R20601-15PGT09-C30R20602-15PGT09-C30R20501-9PGT09-C30R20502-15P
GT09-C30R20401-15P
GT09-C30R20402-15PGT09-C30R20901-25P
GT09-C30R20902-9P
GT09-C30R20903-9PGT09-C30R20904-3CGT09-C30R20201-9PGT09-C30R20202-15PGT09-C30R20203-9PGT09-C30R20204-14PGT09-C30R20205-25P
GT09-C30R20301-9PGT09-C30R20302-9PGT09-C30R20701-9SGT09-C30R20702-25P
GT09-C30R20801-9S
GT09-C30R40101-9PGT09-C100R40101-9PGT09-C200R40101-9PGT09-C300R40101-9PGT09-C30R40102-9PGT09-C100R40102-9PGT09-C200R40102-9PGT09-C300R40102-9PGT09-C30R41101-5TGT09-C100R41101-5TGT09-C200R41101-5TGT09-C300R41101-5TGT09-C30R40601-15PGT09-C100R40601-15PGT09-C200R40601-15PGT09-C300R40601-15PGT09-C30R40602-15PGT09-C100R40602-15PGT09-C200R40602-15PGT09-C300R40602-15PGT09-C30R40603-6TGT09-C100R40603-6TGT09-C200R40603-6TGT09-C300R40603-6TGT09-C30R40501-15PGT09-C100R40501-15PGT09-C200R40501-15PGT09-C300R40501-15PGT09-C30R40502-6CGT09-C100R40502-6CGT09-C200R40502-6CGT09-C300R40502-6CGT09-C30R40503-15PGT09-C100R40503-15PGT09-C200R40503-15PGT09-C300R40503-15PGT09-C30R40401-7TGT09-C100R40401-7TGT09-C200R40401-7TGT09-C300R40401-7TGT09-C30R40201-9PGT09-C100R40201-9PGT09-C200R40201-9PGT09-C300R40201-9PGT09-C30R40202-14PGT09-C100R40202-14PGT09-C200R40202-14PGT09-C300R40202-14PGT09-C30R40301-6TGT09-C100R40301-6TGT09-C200R40301-6TGT09-C300R40301-6TGT09-C30R40302-6TGT09-C100R40302-6TGT09-C200R40302-6TGT09-C300R40302-6T
3m
3m3m3m3m3m3m3m3m3m
3m
3m3m
3m
3m3m3m3m3m3m3m
3m3m3m3m
3m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
3m10m20m30m
PLC CPU: CQM1/CQM1H/CS1/CJ1/CV500/CV1000/CV2000/CVM1Serial communication unit: CS1W-SCU21Communication board: C200HW-COM2/COM05/COM06Serial communication board: CQM1-SCB41/CS1W-SCB41/CS1W-SCB21Connection cable: CQM1-CIF01Base mounted type upper link unit: C500H-LK201-V1PLC CPU: KV-700/1000Communication unit: KV-L20/L20R port1Communication unit: KV-L20/L20R port2PLC CPU: JW-22CU/70CUH/100CUH/100CUPLC CPU: JW-32CUH/33CUHPLC CPU: T2EPLC CPU: T2NPLC CPU: H-4010/H series board type/EH-150 seriesIntelligent serial port module: COMM-H/COMM-2HPLC CPU: H-4010/EH-150 seriesRS-422/232 conversion adaptor: AFP8550PLC CPU: FP2/FP2SH/FP10(S)/FP10SH/FP-MComputer communication unit: AFP2462/AFP3462/AFP5462PLC CPU: FP1-C24C/C40CPLC CPU: FP1-C16CT/C32CTPLC CPU: PROGIC-8/MP-920/MP-930PLC CPU: PROGIC-8PLC CPU: CP-9300MS MEMOBUS module: CP-217IFPLC CPU: MP-940MEMOBUS module: CP-217IF Yokogawa Electric personal computer module: LC01-0N/LC02-0NCPU port/D-sub 9-pin conversion cable: KM10-0CPersonal computer module: F3LC11-1N/F3LC11-1F/F3LC12-1F/F3LC11-2NPLC CPU: SL500 series Converter: 1761-NET-AICAdaptor: 1770-KF3
HMI adaptor
PLC CPU: CV500/CV1000/CV2000/CVM1Communication board: C200HW-COM03/COM06Serial communication board: CQM1-SCB41/CS1W-SCB41
Base mounted type upper link unit: C200H-LK202-V1/C500H-LK201-V1
Communication unit: KV-L20/L20R port2
PLC CPU: JW-22CU/70CUH/100CUH/100CU
PLC CPU: JW-32CUH/33CUH
Link unit: JW-21CM/10CM/ZW-10CM
PLC CPU: T2/T3/T3H/model3000(S3)
PLC CPU: T2E
PLC CPU: T2N
Intelligent serial port module: COMM-H/COMM-2H
MEMOBUS module: JAMSC-120NOM27100/JAMSC-IF612
PLC CPU: MP940
Personal computer link module: F3LC11-2N
Personal computer link module: LC01-0N/LC02-0N
Product name Model name GOT connection destination
Cables for other brand PLC
L i s t o f p r o d u c t s
58 59
List o
f pro
du
cts
GT15 GT11 Handy GOTApplicable model
GT15 GT11 Handy GOT
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
GT15-QC06B
GT15-QC12B
GT15-QC30B
GT15-QC50B
GT15-QC100B
GT15-QC150BS
GT15-QC200BS
GT15-QC250BS
GT15-QC300BS
GT15-QC350BS
A9GT-QCNB
GT15-C12NB
GT15-C30NB
GT15-C50NB
GT15-AC06B
GT15-AC12B
GT15-AC30B
GT15-AC50B
GT15-A370C12B-S1
GT15-A370C25B-S1
GT15-A370C12B
GT15-A370C25B
GT15-A1SC07B
GT15-A1SC12B
GT15-A1SC30B
GT15-A1SC50B
GT15-A1SC05NB
GT15-A1SC07NB
GT15-A1SC30NB
GT15-A1SC50NB
GT15-C100EXSS-1
GT15-C200EXSS-1
GT15-C300EXSS-1
GT15-C07BS
GT15-C12BS
GT15-C30BS
GT15-C50BS
GT15-C100BS
GT15-C200BS
GT15-C300BS
GT15-J2C10B
A7GT-CNB
GT15-EXCNB
GT01-C30R4-25P
GT01-C100R4-25P
GT01-C200R4-25P
GT01-C300R4-25P
GT01-C10R4-8P
GT01-C30R4-8P
GT01-C100R4-8P
GT01-C200R4-8P
GT01-C300R4-8P
GT01-C30R2-6P
GT01-C30R2-9S
GT01-C30R2-25P
GT11H-C30-37P
GT11H-C60-37P
GT11H-C100-37P
GT11H-C30
GT11H-C60
GT11H-C100
GT11H-C15R4-8P
GT11H-C15R4-25P
GT11H-C15R2-6P
GT09-C20USB-5P
NEW
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
coming soon
60 61
MemoMemo
Mitsubishi Graphic Operation Terminal
• To use the products given in this catalog properly, always read the "manuals" before starting to use them.
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
For safe useThis catalog explains the typical features and functions of the GOTs and does not provide restrictions and other information on usage and module combinations. When choosing the products, always check the detailed specifications, restrictions, etc. of the products in the user's manuals. When using the products, always read the user's manuals of the products.Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
Precautions for Choosing the Products
When exported from Japan, this manual does not require application to the Ministry of International Trade and Industry for service transaction permission.
ELECTRIC CORPORATION HEAD OFFICE: 1-8-12,OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN
NAGOYA WORKS: 1-14,YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN
Country/Region Sales office Tel/Fax
U.S.A Mitsubishi Electric Automation Inc. Tel : +1-847-478-2100 500 Corporate Woods Parkway Vernon Hills, IL 60061 Fax : +1-847-478-2396
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Tel : +55-11-5908-8331 Rua Correia Dias,184, Edificio Paraiso Trade Center-8 andar Paraiso, Fax : +55-11-5574-5296 Sao Paulo, SP Brazil
Germany Mitsubishi Electric Europe B.V. German Branch Tel : +49-2102-486-0 Gothaer Strasse 8 D-40880 Ratingen, GERMANY Fax : +49-2102-486-7170
U.K Mitsubishi Electric Europe B.V. UK Branch Tel : +44-1707-276100 Travellers Lane, Hatfield, Herts., AL10 8XB,UK Fax : +44-1707-278695
Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : +39-039-60531 Centro Dir. Colleoni, Pal. Perseo - Ingr.2 Fax : +39-039-6053312 Via Paracelso 12, 20041 Agrate B., Milano, Italy
Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : +34-93-565-3131 Carretera de Rubi 76-80 Fax : +34-93-589-2948 08190 Sant Cugat del Valles, Barcelona, Spain
France Mitsubishi Electric Europe B.V. French Branch Tel : +33-1-5568-5568 225 Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : +33-1-5568-5685
South Africa Circuit Breaker Industries LTD Tel : +27-11-928-2000 Private Bag 2016, 1600 Isando, Tripswitch Drive, Elandsfontein Gauteng, South Africa Fax : +27-11-392-2354
Hong Kong Mitsubishi Electric Automation (Hong Kong) Ltd. Tel : +852-2887-8870 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Fax : +852-2887-7984
China Mitsubishi Electric Automation (Shanghai) Ltd. Tel : +86-21-6475-3228 1-3/F., Block5, 103 Cao Bao Road, Shanghai 200233, China Fax : +86-21-6474-6996
Taiwan Setsuyo Enterprise Co., Ltd. Tel : +886-2-2299-2499 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Fax : +886-2-2299-2509
Korea Mitsubishi Electric Automation Korea Co., Ltd. Tel : +82-2-3660-9552 Dong seo Game Channel Bldg. 2F 660-11, Deungchon-dong, Kangseo-ku, Fax : +82-2-3664-8372 Seoul 157-030, Korea
Singapore Mitsubishi Electric Asia Pte, Ltd. Tel : +65-6470-2460 307 Alexandra Road #05-01/02, Fax : +65-6476-7439 Mitsubishi Electric Bulding Singapore 159943
Thailand F.A. Tech Co., Ltd. Tel : +66-2-682-6522 896/19, 20, 21, 22, S. V. City Building, Office Tower 1, Floor Fax : +66-2-682-6020 12 Rama III Rd, Bangpongpang, Yannawa, Bangkok 10120
Indonesia Indonesia P.T. Autoteknindo SUMBER MAKMUR Tel : +62-21-663-0833 Muara Karang Selatan Block A/Utara No.1 Kav. Fax : +62-21-663-0832 No.11 Kawasan Industri/Pergudangan Jakarta-Utara 14440
India Messung Systems Pvt, Ltd. Tel : +91-20-2712-3130 Electronic Sadan NO:111 Unit No15, M.I.D.C Bhosari, Pune-411026, India Fax : +91-20-2712-8180
Australia Mitsubishi Electric Australia Pty. Ltd. Tel : +61-2-9684-7777 348 Victoria Road, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245
New publication, effective November, 2005Specifications subject to change without notice.L(NA)08054E-B 0511(MDOC)